Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 312
Filtrar
1.
J Voice ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39112118

RESUMO

OBJECTIVE: Vocalizations from infants, particularly sounds associated with respiratory distress, are fundamental for observational scoring of respiratory tract issues. Listening to these infant sounds is a prevalent technique for decision-making in newborn intensive care units. Expiratory grunting, indicative of the severity and presence of potential conditions, is valuable, however, this evaluative method is subjective and prone to error. This study investigates the potential of computer-aided analysis to offer an objective scale for assessing the severity of respiratory tract problems, utilizing digital recordings of grunting sounds. METHODS: The original data set is formed with a total of 189 grunting sound segments collected from 38 infants. Multiple evaluation approaches were performed to reveal the relation between spectral characteristics of the recordings and the severity or existence of respiratory distress. RESULTS: Three spectral features were evaluated as prominently related to hospital stay duration and respiratory distress. The harmonic ratio of the recordings was graded as the most-related spectral feature that would characterize the severity. CONCLUSIONS: The potential of an innovative and objective grading approach is first investigated for replacing the human ear with a computer-aided evaluation system. The results are promising and the detected relation between expert ear-based scoring and harmonic ratio suggests that the spectral character of the grunting sounds would reflect the nature of respiratory conditions. Moreover, this study underlines those spectral features of digital grunting recordings that would be functional for automated prediction and decision-making.

2.
J Neuroeng Rehabil ; 21(1): 129, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39085937

RESUMO

BACKGROUND: Positional preferences, asymmetry of body position and movements potentially indicate abnormal clinical conditions in infants. However, a lack of standardized nomenclature hinders accurate assessment and documentation of these preferences over time. Video tools offer a safe and reproducible method to analyze and describe infant movement patterns, aiding in physiotherapy management and goal planning. The study aimed to develop an objective classification system for infant movement patterns with particular emphasis on the specific distribution of muscle tension, using methods of computer analysis of video recordings to enhance accuracy and reproducibility in assessments. METHODS: The study involved the recording of videos of 51 infants between 6 and 15 weeks of age, born at term, with an Apgar score of at least 8 points. Based on observations of a recording of infant spontaneous movements in the supine position, experts identified postural-motor patterns: symmetry and typical asymmetry linked to the asymmetrical tonic neck reflex. Deviations from the typical postural-motor system were indicated, and subcategories of atypical patterns were distinguished. A computer-based inference system was developed to automatically classify individual patterns. RESULTS: The following division of motor patterns was used: (1) normal patterns, including (a) typical (symmetrical, asymmetrical: variants 1 and 2); and (b) atypical (variants: 1 to 4), (2) positional preference, and (3) abnormal patterns. The proposed automatic classification method achieved an expert decision mapping accuracy of 84%. For atypical patterns, the high reproducibility of the system's results was confirmed. Lower reproducibility, not exceeding 70%, was achieved with typical patterns. CONCLUSIONS: Based on the observation of infant spontaneous movements, it is possible to identify movement patterns divided into typical and atypical patterns. Computer-based analysis of infant movement patterns makes it possible to objectify and satisfactorily reproduce diagnostic decisions.


Assuntos
Movimento , Gravação em Vídeo , Humanos , Lactente , Movimento/fisiologia , Gravação em Vídeo/métodos , Feminino , Masculino , Reprodutibilidade dos Testes , Postura/fisiologia
3.
BMC Prim Care ; 25(1): 267, 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39033295

RESUMO

BACKGROUND: Atrial fibrillation (AF) is highly correlated with heart failure, stroke and death. Screening increases AF detection and facilitates the early adoption of comprehensive intervention. Long-term wearable devices have become increasingly popular for AF screening in primary care. However, interpreting data obtained by long-term wearable ECG devices is a problem in primary care. To diagnose the disease quickly and accurately, we aimed to build AF episode detection model based on a nonlinear Lorenz scattergram (LS) and deep learning. METHODS: The MIT-BIH Normal Sinus Rhythm Database, MIT-BIH Arrhythmia Database and the Long-Term AF Database were extracted to construct the MIT-BIH Ambulatory Electrocardiograph (MIT-BIH AE) dataset. We converted the long-term ECG into a two-dimensional LSs. The LSs from MIT-BIH AE dataset was randomly divided into training and internal validation sets in a 9:1 ratio, which was used to develop and internally validated model. We built a MOBILE-SCREEN-AF (MS-AF) dataset from a single-lead wearable ECG device in primary care for external validation. Performance was quantified using a confusion matrix and standard classification metrics. RESULTS: During the evaluation of model performance based on the LS, the sensitivity, specificity and accuracy of the model in diagnosing AF were 0.992, 0.973, and 0.983 in the internal validation set respectively. In the external validation set, these metrics were 0.989, 0.956, and 0.967, respectively. Furthermore, when evaluating the model's performance based on ECG records in the MS-AF dataset, the sensitivity, specificity and accuracy of model diagnosis paroxysmal AF were 1.000, 0.870 and 0.876 respectively, and 0.927, 1.000 and 0.973 for the persistent AF. CONCLUSIONS: The model based on the nonlinear LS and deep learning has high accuracy, making it promising for AF screening in primary care. It has potential for generalization and practical application.


Assuntos
Fibrilação Atrial , Aprendizado Profundo , Atenção Primária à Saúde , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Dispositivos Eletrônicos Vestíveis , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Masculino , Sensibilidade e Especificidade , Feminino
4.
J Clin Med ; 13(14)2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-39064078

RESUMO

This study explores the efficacy of texture analysis by using preoperative multi-slice spiral computed tomography (MSCT) to non-invasively determine the grade of cellular differentiation in head and neck squamous cell carcinoma (HNSCC). In a retrospective study, MSCT scans of patients with HNSCC were analyzed and classified based on its histological grade as moderately differentiated, well-differentiated, or poorly differentiated. The location of the tumor was categorized as either in the bone or in soft tissues. Segmentation of the lesion areas was conducted, followed by texture analysis. Eleven GLCM parameters across five different distances were calculated. Median values and correlations of texture parameters were examined in relation to tumor differentiation grade by using Spearman's correlation coefficient and Kruskal-Wallis and Dunn tests. Forty-six patients were included, predominantly female (87%), with a mean age of 66.7 years. Texture analysis revealed significant parameter correlations with histopathological grades of tumor differentiation. The study identified no significant age correlation with tumor differentiation, which underscores the potential of texture analysis as an age-independent biomarker. The strong correlations between texture parameters and histopathological grades support the integration of this technique into the clinical decision-making process.

5.
J Clin Med ; 13(14)2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39064244

RESUMO

Background: Obstructive sleep apnea (OSA) affects a significant proportion of the global population, with many having moderate or severe forms of the disease. Home Sleep Apnea Testing (HSAT) has become the most common method of diagnosing OSA, replacing in-lab polysomnography. Polysmith software Version 11 by Nihon Kohden allows for the automatic scoring of respiratory events. This study aimed to assess the validity of this technology. Study Objectives: The objective was to assess the accuracy of the Polysmith Software Automatic Scoring Algorithm of HSATs in comparison to that of sleep technicians. Methods: One hundred twenty HSATs were scored by both sleep technicians and Polysmith software. The measured values were the respiratory event index (REI), apneic events, and hypopneic events. Agreement between the two methods was reached by utilizing the Kruskal-Wallis test, Pearson correlation coefficient, and Bland-Altman plot, as well as sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Results: The correlation between the REI calculated by the software and technicians proved to be strong overall (r = 0.96, p < 0.0001). The mild OSA group had a moderate correlation (r = 0.45, p = 0.0129). The primary snoring, moderate OSA, and severe OSA groups showed stronger correlations (r = 0.69, p < 0.0001; r = 0.56, p = 0.012; r = 0.71, p < 0.0001). The analysis conducted across all groups demonstrated an average sensitivity of 81%, specificity of 94%, PPV of 82%, and NPV of 94%, with an overall accuracy of 81%. When combining the moderate and severe OSA groups into a single category, the sensitivity was 90%, specificity was 100%, PPV was 100%, and NPV was 91%. Conclusions: OSA can be reliably diagnosed from HSATs with the automated Polysmith software across all OSA disease severity groups, with higher levels of accuracy in moderate/severe OSA and lower levels of accuracy in mild OSA.

6.
Acta Radiol ; : 2841851241266369, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39043232

RESUMO

Radiographic measurements play a crucial role in evaluating the alignment of distal radius fractures (DRFs). Various manual methods have been used to perform the measurements, but they are susceptible to inaccuracies. Recently, computer-aided methods have become available. This review explores the methods commonly used to assess DRFs. The review introduces the different measurement techniques, discusses the sources of measurement errors and measurement reliability, and provides a recommendation for their use. Radiographic measurements used in the evaluation of DRFs are not reliable. Standardizing the measurement techniques is crucial to address this and automated image analysis could help improve accuracy and reliability.

7.
Eur Radiol ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38861161

RESUMO

PURPOSE: This work aims to assess standard evaluation practices used by the research community for evaluating medical imaging classifiers, with a specific focus on the implications of class imbalance. The analysis is performed on chest X-rays as a case study and encompasses a comprehensive model performance definition, considering both discriminative capabilities and model calibration. MATERIALS AND METHODS: We conduct a concise literature review to examine prevailing scientific practices used when evaluating X-ray classifiers. Then, we perform a systematic experiment on two major chest X-ray datasets to showcase a didactic example of the behavior of several performance metrics under different class ratios and highlight how widely adopted metrics can conceal performance in the minority class. RESULTS: Our literature study confirms that: (1) even when dealing with highly imbalanced datasets, the community tends to use metrics that are dominated by the majority class; and (2) it is still uncommon to include calibration studies for chest X-ray classifiers, albeit its importance in the context of healthcare. Moreover, our systematic experiments confirm that current evaluation practices may not reflect model performance in real clinical scenarios and suggest complementary metrics to better reflect the performance of the system in such scenarios. CONCLUSION: Our analysis underscores the need for enhanced evaluation practices, particularly in the context of class-imbalanced chest X-ray classifiers. We recommend the inclusion of complementary metrics such as the area under the precision-recall curve (AUC-PR), adjusted AUC-PR, and balanced Brier score, to offer a more accurate depiction of system performance in real clinical scenarios, considering metrics that reflect both, discrimination and calibration performance. CLINICAL RELEVANCE STATEMENT: This study underscores the critical need for refined evaluation metrics in medical imaging classifiers, emphasizing that prevalent metrics may mask poor performance in minority classes, potentially impacting clinical diagnoses and healthcare outcomes. KEY POINTS: Common scientific practices in papers dealing with X-ray computer-assisted diagnosis (CAD) systems may be misleading. We highlight limitations in reporting of evaluation metrics for X-ray CAD systems in highly imbalanced scenarios. We propose adopting alternative metrics based on experimental evaluation on large-scale datasets.

8.
Asian Spine J ; 18(3): 407-414, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38917858

RESUMO

STUDY DESIGN: An experimental study. PURPOSE: This study aimed to investigate the potential use of artificial neural networks (ANNs) in the detection of odontoid fractures using the Konstanz Information Miner (KNIME) Analytics Platform that provides a technique for computer-assisted diagnosis using radiographic X-ray imaging. OVERVIEW OF LITERATURE: In medical image processing, computer-assisted diagnosis with ANNs from radiographic X-ray imaging is becoming increasingly popular. Odontoid fractures are a common fracture of the axis and account for 10%-15% of all cervical fractures. However, a literature review of computer-assisted diagnosis with ANNs has not been made. METHODS: This study analyzed 432 open-mouth (odontoid) radiographic views of cervical spine X-ray images obtained from dataset repositories, which were used in developing ANN models based on the convolutional neural network theory. All the images contained diagnostic information, including 216 radiographic images of individuals with normal odontoid processes and 216 images of patients with acute odontoid fractures. The model classified each image as either showing an odontoid fracture or not. Specifically, 70% of the images were training datasets used for model training, and 30% were used for testing. KNIME's graphic user interface-based programming enabled class label annotation, data preprocessing, model training, and performance evaluation. RESULTS: The graphic user interface program by KNIME was used to report all radiographic X-ray imaging features. The ANN model performed 50 epochs of training. The performance indices in detecting odontoid fractures included sensitivity, specificity, F-measure, and prediction error of 100%, 95.4%, 97.77%, and 2.3%, respectively. The model's accuracy accounted for 97% of the area under the receiver operating characteristic curve for the diagnosis of odontoid fractures. CONCLUSIONS: The ANN models with the KNIME Analytics Platform were successfully used in the computer-assisted diagnosis of odontoid fractures using radiographic X-ray images. This approach can help radiologists in the screening, detection, and diagnosis of acute odontoid fractures.

9.
Abdom Radiol (NY) ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38916618

RESUMO

OBJECTIVES: To identify lymphatic vascular space invasion (LVSI) and lymphatic node metastasis (LNM) status of endometrial cancer (EC) patients, using radiomics based on MRI images. METHODS: Five hundred and ninety-eight EC patients between January 2015 and September 2020 from two institutions were retrospectively included. Tumoral regions on DWI, T1CE, and T2W images were manually outlined. Radiomics features were extracted from tumor region and peri-tumor region of different thicknesses. We established sub-models to select features from each smaller category. Using this method, we separately constructed radiomic signatures for intra-tumoral and peri-tumoral images using different sequences. We constructed intra-tumoral and peri-tumoral models by combining their features, and a multi-sequence model by combining logits. Models were trained with 397 patients and validated with 170 internal and 31 external patients. RESULTS: For LVSI positive/LNM positive status identification, the multi-parameter MRI radiomics model achieved the area under curve (AUC) values of 0.771 (95%CI: [0.692-0.849])/0.801 (95%CI: [0.704, 0.898]) and 0.864 (95%CI: [0.728-1.000])/0.976 (95%CI: [0.919, 1.000]) in internal and external test cohorts, respectively. CONCLUSIONS: Intra-tumoral and peri-tumoral radiomics signatures based on mpMRI can both be used to identify LVSI or LNM status in EC patients non-invasively. Further studies on LVSI and LNM should pay attention to both of them.

10.
Int J Comput Vis ; 132(7): 2567-2584, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38911323

RESUMO

Pulmonary hypertension (PH) in newborns and infants is a complex condition associated with several pulmonary, cardiac, and systemic diseases contributing to morbidity and mortality. Thus, accurate and early detection of PH and the classification of its severity is crucial for appropriate and successful management. Using echocardiography, the primary diagnostic tool in pediatrics, human assessment is both time-consuming and expertise-demanding, raising the need for an automated approach. Little effort has been directed towards automatic assessment of PH using echocardiography, and the few proposed methods only focus on binary PH classification on the adult population. In this work, we present an explainable multi-view video-based deep learning approach to predict and classify the severity of PH for a cohort of 270 newborns using echocardiograms. We use spatio-temporal convolutional architectures for the prediction of PH from each view, and aggregate the predictions of the different views using majority voting. Our results show a mean F1-score of 0.84 for severity prediction and 0.92 for binary detection using 10-fold cross-validation and 0.63 for severity prediction and 0.78 for binary detection on the held-out test set. We complement our predictions with saliency maps and show that the learned model focuses on clinically relevant cardiac structures, motivating its usage in clinical practice. To the best of our knowledge, this is the first work for an automated assessment of PH in newborns using echocardiograms.

11.
Eur Radiol ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38842692

RESUMO

OBJECTIVES: To develop an automated pipeline for extracting prostate cancer-related information from clinical notes. MATERIALS AND METHODS: This retrospective study included 23,225 patients who underwent prostate MRI between 2017 and 2022. Cancer risk factors (family history of cancer and digital rectal exam findings), pre-MRI prostate pathology, and treatment history of prostate cancer were extracted from free-text clinical notes in English as binary or multi-class classification tasks. Any sentence containing pre-defined keywords was extracted from clinical notes within one year before the MRI. After manually creating sentence-level datasets with ground truth, Bidirectional Encoder Representations from Transformers (BERT)-based sentence-level models were fine-tuned using the extracted sentence as input and the category as output. The patient-level output was determined by compilation of multiple sentence-level outputs using tree-based models. Sentence-level classification performance was evaluated using the area under the receiver operating characteristic curve (AUC) on 15% of the sentence-level dataset (sentence-level test set). The patient-level classification performance was evaluated on the patient-level test set created by radiologists by reviewing the clinical notes of 603 patients. Accuracy and sensitivity were compared between the pipeline and radiologists. RESULTS: Sentence-level AUCs were ≥ 0.94. The pipeline showed higher patient-level sensitivity for extracting cancer risk factors (e.g., family history of prostate cancer, 96.5% vs. 77.9%, p < 0.001), but lower accuracy in classifying pre-MRI prostate pathology (92.5% vs. 95.9%, p = 0.002) and treatment history of prostate cancer (95.5% vs. 97.7%, p = 0.03) than radiologists, respectively. CONCLUSION: The proposed pipeline showed promising performance, especially for extracting cancer risk factors from patient's clinical notes. CLINICAL RELEVANCE STATEMENT: The natural language processing pipeline showed a higher sensitivity for extracting prostate cancer risk factors than radiologists and may help efficiently gather relevant text information when interpreting prostate MRI. KEY POINTS: When interpreting prostate MRI, it is necessary to extract prostate cancer-related information from clinical notes. This pipeline extracted the presence of prostate cancer risk factors with higher sensitivity than radiologists. Natural language processing may help radiologists efficiently gather relevant prostate cancer-related text information.

12.
Ultrasound Med Biol ; 50(8): 1194-1202, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38734528

RESUMO

OBJECTIVES: To assess the value of 3D multiparametric ultrasound imaging, combining hemodynamic and tissue stiffness quantifications by machine learning, for the prediction of prostate biopsy outcomes. METHODS: After signing informed consent, 54 biopsy-naïve patients underwent a 3D dynamic contrast-enhanced ultrasound (DCE-US) recording, a multi-plane 2D shear-wave elastography (SWE) scan with manual sweeping from base to apex of the prostate, and received 12-core systematic biopsies (SBx). 3D maps of 18 hemodynamic parameters were extracted from the 3D DCE-US quantification and a 3D SWE elasticity map was reconstructed based on the multi-plane 2D SWE acquisitions. Subsequently, all the 3D maps were segmented and subdivided into 12 regions corresponding to the SBx locations. Per region, the set of 19 computed parameters was further extended by derivation of eight radiomic features per parameter. Based on this feature set, a multiparametric ultrasound approach was implemented using five different classifiers together with a sequential floating forward selection method and hyperparameter tuning. The classification accuracy with respect to the biopsy reference was assessed by a group-k-fold cross-validation procedure, and the performance was evaluated by the Area Under the Receiver Operating Characteristics Curve (AUC). RESULTS: Of the 54 patients, 20 were found with clinically significant prostate cancer (csPCa) based on SBx. The 18 hemodynamic parameters showed mean AUC values varying from 0.63 to 0.75, and SWE elasticity showed an AUC of 0.66. The multiparametric approach using radiomic features derived from hemodynamic parameters only produced an AUC of 0.81, while the combination of hemodynamic and tissue-stiffness quantifications yielded a significantly improved AUC of 0.85 for csPCa detection (p-value < 0.05) using the Gradient Boosting classifier. CONCLUSIONS: Our results suggest 3D multiparametric ultrasound imaging combining hemodynamic and tissue-stiffness features to represent a promising diagnostic tool for biopsy outcome prediction, aiding in csPCa localization.


Assuntos
Técnicas de Imagem por Elasticidade , Imageamento Tridimensional , Próstata , Neoplasias da Próstata , Ultrassonografia , Humanos , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Pessoa de Meia-Idade , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Imageamento Tridimensional/métodos , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia/métodos , Valor Preditivo dos Testes , Biópsia
13.
Artigo em Inglês | MEDLINE | ID: mdl-38795148

RESUMO

PURPOSE: This study evaluates the efficacy of two advanced Large Language Models (LLMs), OpenAI's ChatGPT 4 and Google's Gemini Advanced, in providing treatment recommendations for head and neck oncology cases. The aim is to assess their utility in supporting multidisciplinary oncological evaluations and decision-making processes. METHODS: This comparative analysis examined the responses of ChatGPT 4 and Gemini Advanced to five hypothetical cases of head and neck cancer, each representing a different anatomical subsite. The responses were evaluated against the latest National Comprehensive Cancer Network (NCCN) guidelines by two blinded panels using the total disagreement score (TDS) and the artificial intelligence performance instrument (AIPI). Statistical assessments were performed using the Wilcoxon signed-rank test and the Friedman test. RESULTS: Both LLMs produced relevant treatment recommendations with ChatGPT 4 generally outperforming Gemini Advanced regarding adherence to guidelines and comprehensive treatment planning. ChatGPT 4 showed higher AIPI scores (median 3 [2-4]) compared to Gemini Advanced (median 2 [2-3]), indicating better overall performance. Notably, inconsistencies were observed in the management of induction chemotherapy and surgical decisions, such as neck dissection. CONCLUSIONS: While both LLMs demonstrated the potential to aid in the multidisciplinary management of head and neck oncology, discrepancies in certain critical areas highlight the need for further refinement. The study supports the growing role of AI in enhancing clinical decision-making but also emphasizes the necessity for continuous updates and validation against current clinical standards to integrate AI into healthcare practices fully.

14.
J Dent Sci ; 19(2): 937-944, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618087

RESUMO

Background/purpose: Recently, an artificial intelligence-based computer-assisted diagnosis (AI-CAD) for panoramic radiography was developed to scan the inferior margin of the mandible and automatically evaluate mandibular cortical morphology. The aim of this study was to analyze quantitatively the mandibular cortical morphology using the AI-CAD, especially focusing on underlying diseases and dental status in women over 20 years of age. Materials and methods: 419 patients in women over 20 years of age who underwent panoramic radiography were included in this study. The mandibular cortical morphology was analyzed with an AI-CAD that evaluated the degree of deformation of the mandibular inferior cortex (MIC) and mandibular cortical index (MCI) automatically. Those were analyzed in relation to underlying diseases, such as diabetes, hypertension, dyslipidemia, rheumatism and osteoporosis, and dental status, such as the number of teeth present in the maxilla and mandible. Results: The degree of deformation of MIC in women under 51 years of age (21-50 years; n = 229, 16.0 ± 12.7) was significantly lower than those of over 50 years of age (51-90 years; n = 190, 45.1 ± 23.0), and the MCI was a significant difference for the different age group. Regarding the degree of deformation of MIC and MCI in women over 50 years of age, osteoporosis and number of total teeth present in the maxilla and mandible were significant differences. Conclusion: The results of this study indicated that the mandibular cortical morphology using the AI-CAD is significantly related to osteoporosis and dental status in women over 50 years of age.

16.
Neuroradiology ; 66(7): 1153-1160, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38619571

RESUMO

PURPOSE: To evaluate the impact of an AI-based software trained to detect cerebral aneurysms on TOF-MRA on the diagnostic performance and reading times across readers with varying experience levels. METHODS: One hundred eighty-six MRI studies were reviewed by six readers to detect cerebral aneurysms. Initially, readings were assisted by the CNN-based software mdbrain. After 6 weeks, a second reading was conducted without software assistance. The results were compared to the consensus reading of two neuroradiological specialists and sensitivity (lesion and patient level), specificity (patient level), and false positives per case were calculated for the group of all readers, for the subgroup of physicians, and for each individual reader. Also, reading times for each reader were measured. RESULTS: The dataset contained 54 aneurysms. The readers had no experience (three medical students), 2 years experience (resident in neuroradiology), 6 years experience (radiologist), and 12 years (neuroradiologist). Significant improvements of overall specificity and the overall number of false positives per case were observed in the reading with AI support. For the physicians, we found significant improvements of sensitivity on lesion and patient level and false positives per case. Four readers experienced reduced reading times with the software, while two encountered increased times. CONCLUSION: In the reading with the AI-based software, we observed significant improvements in terms of specificity and false positives per case for the group of all readers and significant improvements of sensitivity and false positives per case for the physicians. Further studies are needed to investigate the effects of the AI-based software in a prospective setting.


Assuntos
Aneurisma Intracraniano , Angiografia por Ressonância Magnética , Sensibilidade e Especificidade , Software , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Competência Clínica , Interpretação de Imagem Assistida por Computador/métodos , Inteligência Artificial , Idoso , Adulto
17.
J Alzheimers Dis ; 98(3): 793-823, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38489188

RESUMO

Background: The growing number of older adults in recent decades has led to more prevalent geriatric diseases, such as strokes and dementia. Therefore, Alzheimer's disease (AD), as the most common type of dementia, has become more frequent too. Background: Objective: The goals of this work are to present state-of-the-art studies focused on the automatic diagnosis and prognosis of AD and its early stages, mainly mild cognitive impairment, and predicting how the research on this topic may change in the future. Methods: Articles found in the existing literature needed to fulfill several selection criteria. Among others, their classification methods were based on artificial neural networks (ANNs), including deep learning, and data not from brain signals or neuroimaging techniques were used. Considering our selection criteria, 42 articles published in the last decade were finally selected. Results: The most medically significant results are shown. Similar quantities of articles based on shallow and deep ANNs were found. Recurrent neural networks and transformers were common with speech or in longitudinal studies. Convolutional neural networks (CNNs) were popular with gait or combined with others in modular approaches. Above one third of the cross-sectional studies utilized multimodal data. Non-public datasets were frequently used in cross-sectional studies, whereas the opposite in longitudinal ones. The most popular databases were indicated, which will be helpful for future researchers in this field. Conclusions: The introduction of CNNs in the last decade and their superb results with neuroimaging data did not negatively affect the usage of other modalities. In fact, new ones emerged.


Assuntos
Doença de Alzheimer , Diagnóstico Precoce , Redes Neurais de Computação , Neuroimagem , Humanos , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/diagnóstico , Prognóstico , Neuroimagem/métodos , Biomarcadores , Disfunção Cognitiva/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico , Aprendizado Profundo
18.
Ultrasound Med Biol ; 50(6): 882-887, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38494413

RESUMO

OBJECTIVE: Deep learning algorithms have commonly been used for the differential diagnosis between benign and malignant thyroid nodules. The aim of the study described here was to develop an integrated system that combines a deep learning model and a clinical standard Thyroid Imaging Reporting and Data System (TI-RADS) for the simultaneous segmentation and risk stratification of thyroid nodules. METHODS: Three hundred four ultrasound images from two independent sites with TI-RADS 4 thyroid nodules were collected. The edge connection and Criminisi algorithm were used to remove manually induced markers in ultrasound images. An integrated system based on TI-RADS and a mask region-based convolution neural network (Mask R-CNN) was proposed to stratify subclasses of TI-RADS 4 thyroid nodules and to segment thyroid nodules in the ultrasound images. Accuracy and the precision-recall curve were used to evaluate stratification performance, and the Dice similarity coefficient (DSC) between the segmentation of Mask R-CNN and the radiologist's contour was used to evaluate the segmentation performance of the model. RESULTS: The combined approach could significantly enhance the performance of the proposed integrated system. Overall stratification accuracy of TI-RADS 4 thyroid nodules, mean average precision and mean DSC of the proposed model in the independent test set was 90.79%, 0.8579 and 0.83, respectively. Specifically, stratification accuracy values for TI-RADS 4a, 4b and 4c thyroid nodules were 95.83%, 84.21% and 77.78%, respectively. CONCLUSION: An integrated system combining TI-RADS and a deep learning model was developed. The system can provide clinicians with not only diagnostic assistance from TI-RADS but also accurate segmentation of thyroid nodules, which improves the applicability of the system in clinical practice.


Assuntos
Aprendizado Profundo , Nódulo da Glândula Tireoide , Ultrassonografia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Humanos , Ultrassonografia/métodos , Medição de Risco , Masculino , Feminino , Glândula Tireoide/diagnóstico por imagem , Pessoa de Meia-Idade , Adulto , Idoso
19.
20.
Med Eng Phys ; 123: 104077, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38365344

RESUMO

The process of feature selection (FS) is vital aspect of machine learning (ML) model's performance enhancement where the objective is the selection of the most influential subset of features. This paper suggests the Gravitational search optimization algorithm (GSOA) technique for metaheuristic-based FS. Glaucoma disease is selected as the subject of investigation as this disease is spreading worldwide at a very fast pace; 111 million instances of glaucoma are expected by 2040, up from 64 million in 2015. It causes widespread vision impairment. Optic nerve fibres can be degraded and cannot be replaced later in this disease. As a starting point, the retinal fundus images of glaucoma infected persons and healthy persons are used, and 36 features were retrieved from these images of public benchmark datasets and private dataset. Six ML models are trained for classification on the basis of the GSOA's returned subset of features. The suggested FS technique enhances classification performance with selection of most influential features. The eight statistical performance evaluating parameters along with execution time are calculated. The training and testing have been performed using a split approach (70:30), 5-fold cross validation (CV), as well as 10-fold CV. The suggested approach achieved 95.36 % accuracy. Due to its auspicious performance, doctors might use the suggested method to receive a second opinion, which would also help overburdened skilled medical practitioners and save patients from vision loss.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Glaucoma , Humanos , Glaucoma/diagnóstico por imagem , Fundo de Olho , Aprendizado de Máquina , Algoritmos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA