Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Access ; 24(3): 370-378, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-34289726

RESUMO

OBJECTIVE: To analyze the effect of multidisciplinary cooperation mode (MCM) led by infusion nurse specialists (INSs) on peripherally inserted central catheters (PICC) catheterization and indwelling nursing quality. METHODS: Participants' demographic information, catheter types, catheterization approaches, puncture site, tip position, professional title of nurses, success rate of catheterization, consultation rate, detection rate of complications and outcome improvement rate of 6576 outpatients and hospitalized patients with PICC were analyzed retrospectively by a software named "questionnaire stars," in a large tertiary general hospital in Shanghai, from January 2015 to December 2019. SPSS 26.0 for Windows was used for data collection and description, Chi-square test were used for statistical analysis of enumeration data, and p < 0.05 was statistically significant. RESULTS: According to the catheter types' data, the use rate of three-way valve catheters decreased from 79.9% to 14.5%, while the use rate of three-way valve solo catheters increased from 12.7% to 51.6%, and the use rate of power injectable and open-ended catheters increased from 7.4% to 33.9%. According to the data of PICC catheterization method, conventional technology decreased significantly from 16.8% to 1.1%, modified Seldinger technique (MST) increased gradually from 26.1% to 51.3%, while ultrasound guided modified Seldinger technique (US and MST) decreased slightly from 57.2% to 47.6%. 7.5% catheter tip ends were malpositioned while nine indwelled PICCs were traced to have tip end malposition. The consultation rate was significantly higher than that before applying MCM led by INSs (x2 = 151.713, p < 0.05). After applying MCM led by INSs, the detection rate of complications was significantly higher than before (x2 = 5.499, p < 0.05), the rate of successful insertion at one time was significantly higher than before (x2 = 187.589, p < 0.05). CONCLUSION: After the application of INSs-led MCM, progresses have been achieved. The nursing quality of patients' PICC was significantly improved than before.


Assuntos
Cateterismo Venoso Central , Cateterismo Periférico , Cateteres Venosos Centrais , Humanos , Estudos Retrospectivos , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , China , Cateteres de Demora , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Catéteres
2.
Colloids Surf B Biointerfaces ; 135: 817-824, 2015 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-26344065

RESUMO

With the idea of improving and advancing the design and preparation of new reagents based on cationic surfactants for gene therapy, two luminescent metallosurfactants derived from the [Ru(2,2'-bpy)3](2+) complex were synthesized. Their interaction with DNA and the effect they exert on the conformation of the polynucleotide were studied by using different techniques. The equilibrium binding constants, Kb, of the two surfactants to DNA were obtained at different molar ratios X=[surfactant]/[DNA]. The observed sigmoidal dependence of Kb on X confirms the cooperative character of the binding. After the addition of a determined surfactant concentration, the condensation of the polymer was observed. The amount of surfactant needed to produce this conformational change is lower for the double stranded surfactant than for the single chain surfactant due to a stronger hydrophobic interaction. The addition of α-cyclodextrin molecules to the metallosurfactant/DNA solutions results in polynucleotide decompaction, which confirms the importance of the hydrophobic interactions in the condensation of the polynucleotide. Results also show the importance of choosing both a proper system to study and the most seeming measuring technique to use. It is demonstrated that, in some cases, the use of several techniques is desirable to obtain reliable and accurate results.


Assuntos
DNA/química , Metais/química , Rubídio/química , Tensoativos/química , Espectrometria de Fluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA