Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.977
Filtrar
1.
J Med Imaging (Bellingham) ; 12(Suppl 1): S13002, 2025 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39055550

RESUMO

Purpose: Accurate detection of microcalcifications ( µ Calcs ) is crucial for the early detection of breast cancer. Some clinical studies have indicated that digital breast tomosynthesis (DBT) systems with a wide angular range have inferior µ Calc detectability compared with those with a narrow angular range. This study aims to (1) provide guidance for optimizing wide-angle (WA) DBT for improving µ Calcs detectability and (2) prioritize key optimization factors. Approach: An in-silico DBT pipeline was constructed to evaluate µ Calc detectability of a WA DBT system under various imaging conditions: focal spot motion (FSM), angular dose distribution (ADS), detector pixel pitch, and detector electronic noise (EN). Images were simulated using a digital anthropomorphic breast phantom inserted with 120 µ m µ Calc clusters. Evaluation metrics included the signal-to-noise ratio (SNR) of the filtered channel observer and the area under the receiver operator curve (AUC) of multiple-reader multiple-case analysis. Results: Results showed that FSM degraded µ Calcs sharpness and decreased the SNR and AUC by 5.2% and 1.8%, respectively. Non-uniform ADS increased the SNR by 62.8% and the AUC by 10.2% for filtered backprojection reconstruction with a typical clinical filter setting. When EN decreased from 2000 to 200 electrons, the SNR and AUC increased by 21.6% and 5.0%, respectively. Decreasing the detector pixel pitch from 85 to 50 µ m improved the SNR and AUC by 55.6% and 7.5%, respectively. The combined improvement of a 50 µ m pixel pitch and EN200 was 89.2% in the SNR and 12.8% in the AUC. Conclusions: Based on the magnitude of impact, the priority for enhancing µ Calc detectability in WA DBT is as follows: (1) utilizing detectors with a small pixel pitch and low EN level, (2) allocating a higher dose to central projections, and (3) reducing FSM. The results from this study can potentially provide guidance for DBT system optimization in the future.

2.
J Pharm Biomed Anal ; 249: 116327, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-39089199

RESUMO

Pharmaceutical manufacturing utilizes solvents at different stages of production. Some of the harmful solvent residuals may be retained in the final product; therefore, they need to be monitored for quality control and to meet the regulation requirement. Here, a novel method capable of rapidly analyzing residual solvents in pharmaceutical products was developed using a compact-portable gas chromatography with a photoionization detector (GC-PID). The method consists of modified Tedlar® bag sampling, online pre-concentration, separation of volatiles by miniaturized GC, and micro-PID detection. The method detection limits of selected residual solvents were in the range of 26.00 - 52.03 pg/mL which is much lower than the pharmaceutical compliance concentration limits. Limits of detection > 520 pg of analyte per grams of sample was also determined for the over-the-counter drugs. The method performance showed rapid speed (5 min), linear calibration (r2 < 0.99), and repeatable retention time (RSD < 0.4 %). Direct analysis of residual solvents in solid samples was conducted without the need for complex sample preparation. The method validation using over-the-counter pharmaceutical products yielded excellent accuracy (recovery > 91.2 %) and precision (RSD < 6.5 %) for the selected residual solvents, including 1,4-dioxane, benzene, chlorobenzene, cyclohexane, xylenes, and toluene. This portable and rapid method could be deployed during the pharmaceutical drug manufacturing processes for quality control.

3.
Appl Spectrosc ; : 37028241267892, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39091019

RESUMO

Raman spectroscopy is among the top analytical techniques for ultra-low-dense organic matter, crucial to the search for life and analysis of celestial body surfaces in space exploration missions. Achieving the ultimate sensitivity in in situ Raman spectroscopy necessitates a breakthrough in detecting inelastically scattered light. Single-photon detectors (SPD) operating in photon counting mode, which can differentiate between Raman and luminescence responses, are promising candidates for the challenging scientific requirements. Since large SPD arrays are not yet commercially available, a dispersive element can be adapted to a single-pixel detector. By exploiting chromatic dispersion in optical fibers and picosecond-pulsed excitation, we delay the arrivals of different spectral components onto a single-pixel SPD. This method also separates weak Raman signals from stronger luminescence through correlated time-domain measurements. We study the impact of fiber properties and the excitation wavelength of a pulsed laser on the spectral resolution of the fiber-dispersive Raman spectrometer (FDRS). Additionally, we demonstrate the FDRS's potential for studying biomarkers and discuss its feasibility for analyzing inclusions in ice matrices.

4.
Artigo em Inglês | MEDLINE | ID: mdl-39110320

RESUMO

To validate the accuracy of coronary artery calcium score (CACS) using photon-counting detector (PCD) CT under various scanning settings and explore the optimized scanning settings considering both the accuracy and the radiation dose. A CACS phantom containing six hollow cylindrical hydroxyapatite calcifications of two sizes with three densities and 12 patients underwent CACS scans. For PCD-CT, two scanning modes (sequence and flash [high-pitch spiral mode]) and five tube voltages (90kV, 120kV, 140kV, Sn100kV, and Sn140kV) at different image quality (IQ) levels were set for phantom, and patients were scanned with 120kV at IQ19 using flash mode. All acquisitions from PCD-CT were reconstructed at 70keV. Acquisitions in sequence mode at 120kV on an energy-integrating detector CT (EID-CT) was used as the reference. Agatston, mass, and volume scores were calculated. The CACS from PCD-CT exhibited excellent agreements with the reference (all intraclass correlation coefficient [ICC] > 0.99). The root mean square error (RMSE) between the Agatston score acquired from PCD-CT and the reference (5.4-11.5) was small. A radiation dose reduction (16-75%) from PCD-CT compared with the reference was obtained in all protocols using flash mode, albeit with IQ20 only at sequence mode (22-44%). For the patients, ICC ( all ICC > 0.98) and Bland-Altman analysis of CACS all showed high agreements between PCD-CT and the reference, without reclassifying CACS categories(P = 0.317). PCD-CT yields repeatable and accurate CACS across diverse scanning protocols according to our pilot study. Sn100kV, 90kV, and 120kV using flash mode at IQ20 are recommended for clinical applications considering both accuracy and radiation dose.

5.
J Appl Crystallogr ; 57(Pt 4): 1107-1114, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39108822

RESUMO

Neutron diffraction beamlines have traditionally relied on deploying large detector arrays of 3He tubes or neutron-sensitive scintillators coupled with photomultipliers to efficiently probe crystallographic and microstructure information of a given material. Given the large upfront cost of custom-made data acquisition systems and the recent scarcity of 3He, new diffraction beamlines or upgrades to existing ones demand innovative approaches. This paper introduces a novel Timepix3-based event-mode imaging neutron diffraction detector system as well as first results of a silicon powder diffraction measurement made at the HIPPO neutron powder diffractometer at the Los Alamos Neutron Science Center. Notably, these initial measurements were conducted simultaneously with the 3He array on HIPPO, enabling direct comparison. Data reduction for this type of data was implemented in the MAUD code, enabling Rietveld analysis. Results from the Timepix3-based setup and HIPPO were benchmarked against McStas simulations, showing good agreement for peak resolution. With further development, systems such as the one presented here may substantially reduce the cost of detector systems for new neutron instrumentation as well as for upgrades of existing beamlines.

6.
J Synchrotron Radiat ; 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39110677

RESUMO

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

7.
Front Public Health ; 12: 1426295, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39100945

RESUMO

Background: In recent years, the incidence of abdominal obesity among the middle-aged and older adult population in China has significantly increased. However, the gender disparities in the spatial distribution of abdominal obesity incidence and its relationship with meteorological factors among this demographic in China remain unclear. This gap in knowledge highlights the need for further research to understand these dynamics and inform targeted public health strategies. Methods: This study utilized data from the 2015 China Health and Retirement Longitudinal Study (CHARLS) to analyze the incidence of abdominal obesity among the middle-aged and older adult population in China. Additionally, meteorological data were collected from the National Meteorological Information Center. Using Moran's I index and Getis-Ord Gi* statistical methods, the spatial distribution characteristics of abdominal obesity incidence were examined. The influence of various meteorological factors on the incidence of abdominal obesity in middle-aged and older adult males and females was investigated using the q statistic from the Geodetector method. Furthermore, Multi-Scale Geographically Weighted Regression (MGWR) analysis was employed to explore the impact of meteorological factors on the spatial heterogeneity of abdominal obesity incidence from a gender perspective. Results: The spatial distribution of abdominal obesity among middle-aged and older adult individuals in China exhibits a decreasing trend from northwest to southeast, with notable spatial autocorrelation. Hotspots are concentrated in North and Northeast China, while cold spots are observed in Southwest China. Gender differences have minimal impact on spatial clustering characteristics. Meteorological factors, including temperature, sunlight, precipitation, wind speed, humidity, and atmospheric pressure, influence incidence rates. Notably, temperature and sunlight exert a greater impact on females, while wind speed has a reduced effect. Interactions among various meteorological factors generally demonstrate bivariate enhancement without significant gender disparities. However, gender disparities are evident in the influence of specific meteorological variables such as annual maximum, average, and minimum temperatures, as well as sunlight duration and precipitation, on the spatial heterogeneity of abdominal obesity incidence. Conclusion: Meteorological factors show a significant association with abdominal obesity prevalence in middle-aged and older adults, with temperature factors playing a prominent role. However, this relationship is influenced by gender differences and spatial heterogeneity. These findings suggest that effective public health policies should be not only gender-sensitive but also locally adapted.


Assuntos
Conceitos Meteorológicos , Obesidade Abdominal , Análise Espacial , Humanos , China/epidemiologia , Masculino , Pessoa de Meia-Idade , Feminino , Obesidade Abdominal/epidemiologia , Idoso , Prevalência , Estudos Longitudinais , Fatores Sexuais , Incidência
8.
J Environ Radioact ; 278: 107511, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39096838

RESUMO

One of the major demands in gamma spectrometry of environmental samples is the accurate determination of activity concentration of present radionuclides (naturally occurring and those of artificial origin), due to the fact they are commonly of relatively low content. Thus, all these measurements have in common that the detection limit, in the spectral region of interest should be as low as possible. For this reason, the construction of a good passive, as well as active shield requires a detailed knowledge of the origin of the background events in the absence of an environmental sample. In addition, an analysis of the impact on detection limits due to the presence of the sample itself is also important. Also, the knowledge of the statistical basics for low-level counting is helpful to enable the best choice of detector characteristics (relative efficiency, peak to Compton ratio, resolution), measuring time, and required level of precaution against the different background contributions. In this paper, the background spectra of several gamma spectroscopy systems (with passive and active veto shields) are analyzed and discussed, regarding their capabilities for measurements of environmental samples. Furthermore, various environmental samples are analyzed by low-level gamma spectrometry, including the sample measurements in the presence of an active veto shield against cosmic-ray muons. The disturbance of radioactive equilibrium between members of radioactive series in the samples is commented on, together with the possibility of use of certain gamma lines (including their interference and the corresponding intensities) for radionuclide activities determination.

9.
Acad Radiol ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39112295

RESUMO

RATIONALE AND OBJECTIVES: To validate the image quality of low-dose ultra-high-resolution (UHR) scanning mode of photon-counting detector CT (PCD-CT) for visceral artery computed tomography angiography (CTA). MATERIAL AND METHODS: We prospectively enrolled 57 patients each in the full dose (FD) and low-dose (LD) protocols, respectively, to undergo abdominal CT scans using the UHR mode on a PCD-CT system (NAEOTOM Alpha), between April 2023 and September 2023. Both the FD data and LD data were then reconstructed into two series of images: (a) 0.2 mm slice thickness, reconstruction kernel Bv48, quantum iterative reconstruction (QIR) 4; (b)1 mm slice thickness, Bv40, QIR 3. The signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) of seven arteries were objectively measured. The image noise, vessel sharpness, overall quality, and visibility of nine arteries were subjectively assessed by three radiologists. RESULTS: The SNRs and CNRs of 0.2 mm reconstruction set was inferior to that of 1 mm reconstruction set (p < 0.001 for all the arteries and noise), however, the image quality of 0.2 mm reconstruction set was higher than that of 1 mm reconstruction set in qualitative evaluation especially for tiny arteries in Volume-rendered (VR) image (p < 0.001). The SNRs and CNRs were not significantly higher for FD group than LD group on the same slice thickness except for SNRs of common hepatic artery, splenic artery and bilateral renal arteries in 0.2 mm reconstruction set. In the comparison on image quality between normal weight and overweight patients within the same reconstruction set, the results showed that low-dose scan did not significantly impact the image quality in overweight patients. The ratings of visibility of nine visceral arteries were not significantly different among FD and LD at the same thickness reconstruction set except for superior mesenteric artery (p = 0.002 and 0.007 for 0.2 mm and 1 mm reconstruction set in axial image; p = 0.002 and 0.007 for 0.2 mm and 1 mm reconstruction set in coronal image, respectively) and left gastric artery (p = 0.002 and p < 0.001 for 0.2 mm and 1 mm reconstruction set in VR image, respectively). CONCLUSION: The low-dose UHR scanning mode of PCD-CT has proven to be adequate for the clinical evaluation of visceral arteries. Utilizing a reconstruction with a slice thickness of 0.2 mm could enhance arterial depiction, particularly for small vessels.

10.
Eur Radiol Exp ; 8(1): 89, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39090380

RESUMO

BACKGROUND: Lower extremity peripheral artery disease frequently presents with calcifications which reduces the accuracy of computed tomography (CT) angiography, especially below-the-knee. Photon-counting detector (PCD)-CT offers improved spatial resolution and less calcium blooming. We aimed to identify the optimal reconstruction parameters for PCD-CT angiography of the lower legs. METHODS: Tubes with different diameters (1-5 mm) were filled with different iodine concentrations and scanned in a water container. Images were reconstructed with 0.4 mm isotropic resolution using a quantitative kernel at all available sharpness levels (Qr36 to Qr76) and using different levels of quantum iterative reconstruction (QIR-2-4). Noise and image sharpness were determined for all reconstructions. Additionally, CT angiograms of 20 patients, reconstructed with a medium (Qr44), sharp (Qr60), and ultrasharp (Qr72) kernel at QIR-2-4, were evaluated by three readers assessing noise, delineation of plaques and vessel walls, and overall quality. RESULTS: In the phantom study, increased kernel sharpness led to higher image noise (e.g., 16, 38, 77 HU for Qr44, Qr60, Qr72, and QIR-3). Image sharpness increased with increasing kernel sharpness, reaching a plateau at the medium-high level 60. Higher QIR levels decreased image noise (e.g., 51, 38, 25 HU at QIR-2-4 and Qr60) without reducing vessel sharpness. The qualitative in vivo results confirmed these findings: the sharp kernel (Qr60) with the highest QIR yielded the best overall quality. CONCLUSION: The combination of a sharpness level optimized reconstruction kernel (Qr60) and the highest QIR level yield the best image quality for PCD-CT angiography of the lower legs when reconstructed at 0.4-mm resolution. RELEVANCE STATEMENT: Using high-resolution PCD-CT angiography with optimized reconstruction parameters might improve diagnostic accuracy and confidence in peripheral artery disease of the lower legs. KEY POINTS: Effective exploitation of the potential of PCD-CT angiography requires optimized reconstruction parameters. Too soft or too sharp reconstruction kernels reduce image quality. The highest level of quantum iterative reconstruction provides the best image quality.


Assuntos
Angiografia por Tomografia Computadorizada , Imagens de Fantasmas , Fótons , Angiografia por Tomografia Computadorizada/métodos , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea , Masculino , Perna (Membro)/diagnóstico por imagem , Perna (Membro)/irrigação sanguínea , Feminino , Idoso , Pessoa de Meia-Idade
11.
Heliyon ; 10(14): e34705, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39130404

RESUMO

The activity concentration of natural radionuclides, radon activity concentration, mass and area exhalation rates have been studied in soils from gold mining communities in Atiwa West district. The natural radionuclides were determined by gamma ray spectrometry method while radon concentrations were measured using CR-39 detectors. The mean activity concentrations were found to be 26.9 ± 1.7 Bq/kg, 57.5 ± 3.6 Bq/kg, 237.5 ± 17.6 Bq/kg and 560.0 ± 54 Bq/m3 for Ra-226, Th-232, K-40 and Rn-222 respectively. The evaluated mass exhalation rates ranged from 2.8 ± 0.3 to 6.5 ± 0.7 × 10-5 Bq/kg/h while the area exhalation rates were from 0.8 ± 0.09 to 2.0 ± 0.21 × 10-3 Bq/m2/h. Some mining and farming areas recorded high exhalation rates indicating that the use of soils as building materials from such areas could pose a level of radiation hazard to the population. The evaluated radiological risks were below reference levels. A good linear correlation was observed between Ra-226 and Rn-222 activity concentrations and in the investigated soils. The Pearson correlation coefficient, cluster analysis and principal component analysis were used to study the relationship between the determined parameters of the study.

12.
Sensors (Basel) ; 24(15)2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39123934

RESUMO

The response of a DPbS3200 infrared detector irradiated by a nanosecond pulsed laser and CW laser has been investigated to study laser-induced interference. A laser interference experiment system was constructed to measure the time-varying response signal. A nanosecond pulsed laser and a CW laser of 10 Hz were used, with a 1064 nm wavelength and a millimeter-scale irradiation spot diameter. Firstly, the characteristics of transient interference signals induced by pulsed lasers were analyzed. Then, the characteristics of response signal interference by both CW laser and pulsed laser irradiation were further investigated. The results showed that the pulsed laser only produced transient interference. However, the CW laser led to a significant amplitude reduction of the response signal, which could continuously interfere in the operating time. For transient interferences, the amplitude of the interference signal increased linearly with the laser fluence. The relation between the pulse repetition rate of the incident laser and the operating frequency of the detector determined the numbers of transient interference signals in one response period; for the interference induced by both the CW laser and pulsed laser, CW laser interference played a leading role when CW laser power density increased to 4.1 W/cm2 or more. As the CW laser fluence reached 6.1 W/cm2, the PbS infrared detector was no longer able to detect any signal, which caused temporary blindness. In the end, a probit model was used to determine the interference threshold.

13.
Sensors (Basel) ; 24(15)2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39123975

RESUMO

This paper presents computer and color vision research focusing on human color perception in VR environments. A VR art gallery with digital twins of original artworks is created for this experiment. In this research, the field of colorimetry and the application of the L*a*b* and RGB color models are applied. The inter-relationships of the two color models are applied to create a color modification of the VR art gallery environment using C# Script procedures. This color-edited VR environment works with a smooth change in color tone in a given time interval. At the same time, a sudden change in the color of the RGB environment is defined in this interval. This experiment aims to record a user's reaction embedded in a VR environment and the effect of color changes on human perception in a VR environment. This research uses lie detector sensors that record the physiological changes of the user embedded in VR. Five sensors are used to record the signal. An experiment on the influence of the user's color perception in a VR environment using lie detector sensors has never been conducted. This research defines the basic methodology for analyzing and evaluating the recorded signals from the lie detector. The presented text thus provides a basis for further research in the field of colors and human color vision in a VR environment and lays an objective basis for use in many scientific and commercial areas.

14.
Sensors (Basel) ; 24(15)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39124034

RESUMO

Static and mobile radiation detectors can be deployed in urban environments for a range of nuclear security applications, including radiological source search-and-tracking scenarios. Modeling detector performance for such applications is challenging, as it does not depend solely on the detector capabilities themselves. Many factors must be taken into consideration, including specific source and background signatures, the topology and constraints of the deployment environment, the presence of nuisance sources, and whether detectors are mobile or static. When considering the simultaneous deployment of multiple, heterogeneous detectors, assessment of the system-wide performance requires the simulation of the individual detectors, and a system-level analysis of the detection performance. In radiological source search-and-tracking scenarios, performance is mostly dominated by the probability of encounter, which depends on the specifics of a given deployment, e.g., static vs. mobile detectors or a combination of both modalities, the number of detectors deployed, the dynamic vs. static setting of false alarm rates, and individual vs. networked operation. The Urban Deployment Model (UDM) toolset was specifically developed to cover the gap in the available generic frameworks for the simulation of radiation detector deployments at city scales. UDM provides a unified and modular framework to support the simulation and performance characterization of heterogeneous detector deployments in urban environments. This paper presents the key components along the UDM workflow.

15.
Materials (Basel) ; 17(15)2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39124329

RESUMO

Photodetectors have a wide range of applications across various fields. Self-powered photodetectors that do not require external energy have garnered significant attention. The photoelectrochemical type of photodetector is a self-powered device that is both simple to fabricate and offers high performance. However, developing photoelectrochemical photodetectors with superior quality and performance remains a significant challenge. The electrolyte, which is a key component in these detectors, must maintain extensive contact with the semiconductor without degrading its material quality and efficiently catalyze the redox reactions of photogenerated electrons and holes, while also facilitating rapid charge carrier transport. In this study, α-Ga2O3 nanorod arrays were synthesized via a cost-effective hydrothermal method to achieve a self-powered solar-blind photodetector. The impacts of different electrolytes-Na2SO4, NaOH, and Na2CO3-on the photodetector was investigated. Ultimately, a self-powered photodetector with Na2SO4 as the electrolyte demonstrated a stable photoresponse, with the maximum responsivity of 0.2 mA/W at 262 nm with the light intensity of 3.0 mW/cm2, and it exhibited rise and decay times of 0.16 s and 0.10 s, respectively. The α-Ga2O3 nanorod arrays and Na2SO4 electrolyte provided a rapid pathway for the transport of photogenerated carriers and the built-in electric field at the semiconductor-liquid heterojunction interface, which was largely responsible for the effective separation of photogenerated electron-hole pairs that provided the outstanding performance of our photodetector.

16.
Phys Med Biol ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39137803

RESUMO

OBJECTIVE: Multi-energy CT conducted by photon-counting detector has a wide range of applications, especially in multiple contrast agents imaging. However, static multi-energy (SME) CT imaging suffers from higher statistical noise because of increased energy bins with static energy thresholds. Our team has proposed a dynamic dual-energy (DDE) CT detector model and the corresponding iterative reconstruction algorithm to solve this problem. However, rigorous and detailed analysis of the statistical noise characterization in this DDE CT was lacked. APPROACH: Starting from the properties of the Poisson random variable, this paper analyzes the noise characterization of the DDE CT and compares it with the SME CT. It is proved that the multi-energy CT projections and reconstruction images calculated from the proposed DDE CT algorithm have less statistical noise than that of the SME CT. MAIN RESULTS: Simulations and experiments verify that the expectations of the multi-energy CT projections calculated from DDE CT are the same as those of the SME projections. Still, the variance of the former is smaller. We further analyze the convergence of the iterative DDE CT algorithm through simulations and prove that the derived noise characterization can be realized under different CT imaging configurations. SIGNIFICANCE: The low statistical noise characteristics demonstrate the value of DDE CT imaging technology.

17.
Ecol Evol ; 14(8): e70180, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39145039

RESUMO

The Hemiptera insects are the largest incomplete metamorphosis insect group in Insecta and play a vital role in ecosystems and biodiversity. Previous studies on the spatial distribution of Hemiptera insects mainly focused on a specific region and insect, this study explored the spatial distribution characteristics of Hemiptera insects in China (national scale), and further clarified the dominant factors affecting their spatial distribution. We used spatial autocorrelation analysis, hot spot analysis, and standard ellipse to investigate the spatial distribution characteristics of Hemiptera insects in China. Furthermore, we used geographic detectors to identify the main factors affecting their spatial distribution under China's six agricultural natural divisions and explore the influencing mechanism of dominant factors. The results show that: (i) The spatial differentiation characteristics of Hemiptera insects in China are significant, and their distribution has obvious spatial agglomeration. The Hu Huanyong Line is an important dividing line for the spatial distribution of Hemiptera insects in China. From the city scale, the HH type (high-high cluster) is mainly distributed on both sides of the Hu Huanyong Line. (ii) The hot spots of Hemiptera insects are mainly distributed in southwest China, along the Qinling Mountains, the western side of the Wuyi Mountains, the Yinshan Mountains, the Liupanshan Mountains, the Xuefeng Mountains, the Nanling Mountains, and other mountainous areas. (iii) Under agricultural natural divisions, the influence of natural environmental factors on the spatial distribution of Hemiptera insects is obviously different. Temperature and precipitation are the dominant factors. Natural factors and socio-economic factors have formed a positive reinforcement interaction mode on the spatial distribution of Hemiptera insects. These can provide the decision-making basis for biodiversity conservation and efficient pest control.

18.
Insights Imaging ; 15(1): 210, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39145877

RESUMO

OBJECTIVES: To evaluate the diagnostic accuracy of liver dual-layer spectral-detector CT (SDCT) derived parameters of liver parenchyma for grading steatosis with reference to magnetic resonance imaging-based proton density fat fraction (MRI-PDFF). METHODS: Altogether, 320 consecutive subjects who underwent MRI-PDFF and liver SDCT examinations were recruited and prospectively enrolled from four Chinese hospital centers. Participants were classified into normal (n = 152), mild steatosis (n = 110), and moderate/severe(mod/sev) steatosis (n = 58) groups based on MRI-PDFF. SDCT liver parameters were evaluated using conventional polychromatic CT images (CTpoly), virtual mono-energetic images at 40 keV (CT40kev), the slope of the spectral attenuation curve (λ), the effective atomic number (Zeff), and liver to spleen attenuation ratio (L/S ratio). Linearity between SDCT liver parameters and MRI-PDFF was examined using Spearman correlation. Cutoff values for SDCT liver parameters in determining steatosis grades were identified using the area under the receiver-operating characteristic curve analyses. RESULTS: SDCT liver parameters demonstrated a strong correlation with PDFF, particularly Zeff (rs = -0.856; p < 0.001). Zeff achieved an area under the curve (AUC) of 0.930 for detecting the presence of steatosis with a sensitivity of 89.4%, a specificity of 82.4%, and an AUC of 0.983 for detecting mod/sev steatosis with a sensitivity of 93.1%, a specificity of 93.5%, the corresponding cutoff values were 7.12 and 6.94, respectively. Zeff also exhibited good diagnostic performance for liver steatosis grading in subgroups, independent of body mass index. CONCLUSION: SDCT liver parameters, particularly Zeff, exhibit excellent diagnostic accuracy for grading steatosis. CRITICAL RELEVANCE STATEMENT: Dual-layer SDCT parameter, Zeff, as a more convenient and accurate imaging biomarker may serve as an alternative indicator for MRI-based proton density fat fraction, exploring the stage and prognosis of liver steatosis, and even metabolic risk assessment. KEY POINTS: Liver biopsy is the standard for grading liver steatosis, but is limited by its invasive nature. The diagnostic performance of liver steatosis using SDCT-Zeff outperforms conventional CT parameters. SDCT-Zeff accurately and noninvasively assessed the grade of liver steatosis.

19.
Sci Rep ; 14(1): 18828, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39138280

RESUMO

The global challenge of on-site detection of highly enriched uranium (HEU), a substance with considerable potential for unauthorized use in nuclear security, is a critical concern. Traditional passive nondestructive assay (NDA) techniques, such as gamma-ray spectroscopy with high-purity germanium detectors, face significant challenges in detecting HEU when it is shielded by heavy metals. Addressing this critical security need, we introduce an on-site detection method for lead-shielded HEU employing a transportable NDA system that utilizes the 252Cf rotation method with a water Cherenkov neutron detector. This cost-effective NDA system is capable of detecting 4.17 g of 235U within a 12 min measurement period using a 252Cf source of 3.7 MBq. Integrating this system into border control measures can enhance the prevention of HEU proliferation significantly and offer robust deterrence against nuclear terrorism.

20.
Talanta ; 280: 126697, 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39142132

RESUMO

We describe a nitrogen-specific detector (NSD) for aqueous mobile phase-based high performance liquid chromatography (HPLC). It is based by means of total hydrophilic organic nitrogen detection. Separated analytes are photooxidized online and converted to nitrate, followed by an ultravilet absorbance detector. It features response dependant on the product of nitrogen number in the molecule and its molar concentration, no matter what is ultravilet-absorbing or not. The HPLC equipped with NSD can quantify nitrogen-containing analytes via a sole standard of potassium nitrate for calibration. This results in identical calibration curve for all nitrogen-containing analytes, obviating individual calibration. The limit of detection of NSD is 4.3 µM N/L, and its linear range is up to 4 mM N/L.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA