Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Eur Heart J Cardiovasc Imaging ; 25(6): 727-734, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38635738

RESUMO

AIMS: The European Association of Cardiovascular Imaging (EACVI) Scientific Initiatives Committee performed a global survey on radiation exposure in interventional echocardiography. The survey aimed to collect data on local practices for radioprotection in interventional echocardiography and to assess the awareness of echocardiography operators about radiation-related risks. METHODS AND RESULTS: A total of 258 interventional echocardiographers from 52 different countries (48% European) responded to the survey. One hundred twenty-two (47%) participants were women. Two-thirds (76%) of interventional echocardiographers worked in tertiary care/university hospitals. Interventional echocardiography was the main clinical activity for 34% of the survey participants. The median time spent in the cath-lab for the echocardiographic monitoring of structural heart procedures was 10 (5-20) hours/month. Despite this, only 28% of interventional echocardiographers received periodic training and certification in radioprotection and 72% of them did not know their annual radiation dose. The main adopted personal protection devices were lead aprons and thyroid collars (95% and 92% of use, respectively). Dedicated architectural protective shielding was not available for 33% of interventional echocardiographers. Nearly two-thirds of responders thought that the radiation exposure of interventional echocardiographers was higher than that of interventional cardiologists and 72% claimed for an improvement in the radioprotection measures. CONCLUSION: Radioprotection measures for interventional echocardiographers are widely variable across centres. Radioprotection devices are often underused by interventional echocardiographers, portending an increased radiation-related risk. International scientific societies working in the field should collaborate to endorse radioprotection training, promote reliable radiation dose assessment, and support the adoption of radioprotection shielding dedicated to interventional echocardiographers.


Assuntos
Ecocardiografia , Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Feminino , Exposição Ocupacional/prevenção & controle , Exposição à Radiação/prevenção & controle , Masculino , Europa (Continente) , Inquéritos e Questionários , Doses de Radiação , Adulto , Pessoa de Meia-Idade , Ultrassonografia de Intervenção
2.
Eur Heart J Cardiovasc Imaging ; 25(7): 892-900, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38568982

RESUMO

AIMS: To assess the current role of cardiac imaging in the diagnosis, management, and follow-up of patients with acute myocarditis (AM) through a European Association of Cardiovascular Imaging survey. METHODS AND RESULTS: A total of 412 volunteers from 74 countries responded to the survey. Most participants worked in tertiary centres (56%). All participants had access to echocardiography, while 79 and 75% had access to cardiac computed tomography angiography (CCTA) and cardiac magnetic resonance (CMR), respectively. Less than half (47%) had access to myocardial biopsy, and only 5% used this test routinely. CMR was performed within 7 days of presentation in 73% of cases. Non-ischaemic late gadolinium enhancement (LGE, 88%) and high-signal intensity in T2-weighted images (74%) were the most used diagnostic criteria for AM. CCTA was preferred to coronary angiography by 47% of participants to exclude coronary artery disease. Systematic prescription of beta-blockers and angiotensin-converting enzyme inhibitors was reported by 38 and 32% of participants. Around a quarter of participants declared considering LGE burden as a reason to treat. Most participants (90%) reported performing a follow-up echocardiogram, while 63% scheduled a follow-up CMR. The main reason for treatment discontinuation was improvement of left ventricular ejection fraction (89%), followed by LGE regression (60%). In two-thirds of participants, the decision to resume high-intensity sport was influenced by residual LGE. CONCLUSION: This survey confirms the high utilization of cardiac imaging in AM but reveals major differences in how cardiac imaging is used and how the condition is managed between centres, underlining the need for recommendation statements in this topic.


Assuntos
Imagem Multimodal , Miocardite , Humanos , Miocardite/diagnóstico por imagem , Masculino , Feminino , Europa (Continente) , Doença Aguda , Imagem Cinética por Ressonância Magnética/métodos , Angiografia por Tomografia Computadorizada , Adulto , Ecocardiografia , Pessoa de Meia-Idade , Sociedades Médicas , Inquéritos e Questionários , Angiografia Coronária
3.
Eur Heart J Cardiovasc Imaging ; 25(5): 573-578, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38387435

RESUMO

AIMS: To evaluate the diagnosis and imaging of patients with mitral regurgitation (MR) and the management in routine clinical practice across Europe, the European Association of Cardiovascular Imaging Scientific Initiatives Committee performed a survey across European centres. In particular, the routine use of echocardiography, advanced imaging modalities, heart valve clinics, and heart valve teams was explored. METHODS AND RESULTS: A total of 61 responders, mainly from tertiary centres or university hospitals, from 26 different countries responded to the survey, which consisted of 22 questions. For most questions related to echocardiography and advanced imaging, the answers were relatively homogeneous and demonstrated good adherence to current recommendations. In particular, the centres used a multi-parametric echocardiographic approach and selected the effective regurgitant orifice and vena contracta width as their preferred assessments. 2D measurements are still the most widely used parameters to assess left ventricular structure; however, the majority use 3D trans-oesophageal echocardiography (TOE) to evaluate valve morphology in severe MR. The majority of centres reported the onsite availability and clinical use of ergometric stress echocardiography, cardiac computed tomography (CCT), and cardiac magnetic resonance (CMR) imaging. Heart valve clinics and heart valve teams were also widely prevalent. CONCLUSION: Consistent with current guidelines, echocardiography (transthoracic echocardiography and TOE) remains the first-line and central imaging modality for the assessment of MR although the complementary use of 3D TOE, CCT, and CMR appears to be growing. Heart valve clinics and heart valve teams are now widely prevalent.


Assuntos
Insuficiência da Valva Mitral , Insuficiência da Valva Mitral/diagnóstico por imagem , Humanos , Europa (Continente) , Feminino , Masculino , Sociedades Médicas , Ecocardiografia/métodos , Inquéritos e Questionários , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Técnicas de Imagem Cardíaca , Imagem Cinética por Ressonância Magnética/métodos , Padrões de Prática Médica/estatística & dados numéricos , Índice de Gravidade de Doença , Pessoa de Meia-Idade
4.
JACC Asia ; 2(1): 73-84, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36340256

RESUMO

Background: Atrial fibrillation (AF) is common in heart failure with preserved ejection fraction (HFpEF). Objectives: This study aimed to investigate the prognostic value of echocardiographic markers of congestion that can be applied to both AF and patients without AF with HFpEF. Methods: We conducted a multicenter study of 505 patients with HFpEF admitted to hospitals for acute decompensated heart failure. The ratio of early diastolic transmitral flow velocity to mitral annulus velocity (E/e'), the tricuspid regurgitation peak velocity, and the collapsibility of the inferior vena cava were obtained at discharge. Congestion was determined by echocardiography if any one of E/e' ≥14 (E/e' ≥11 for AF), tricuspid regurgitation peak velocity ≥2.8 m/s, or inferior vena cava collapsibility <50% was positive. We classified patients into grade A, grade B, and grade C according to the number of positive congestion indices. The primary endpoint was the composite of cardiovascular death and heart failure hospitalization. Results: During the follow-up period (median: 373 days), 162 (32%) patients experienced the primary endpoint. Grade C patients had a higher risk for the primary endpoint than grade A (HR: 2.98; 95% CI: 1.97-4.52) and grade B patients (HR: 1.92; 95% CI: 1.29-2.86) (log-rank P < 0.0001). Echocardiographic congestion grade improved the predictive value when added to the age, sex, New York Heart Association functional class, and N-terminal pro-B-type natriuretic peptide, not only in sinus rhythm (Uno C-statistic: 0.670 vs 0.655) but in AF (Uno C-statistic: 0.667 vs 0.639). Conclusions: Echocardiographic congestion grade has prognostic value in patients with HFpEF with and without AF.

5.
Eur Heart J Cardiovasc Imaging ; 23(11): 1417-1422, 2022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-36093580

RESUMO

AIMS: The European Association of Cardiovascular Imaging (EACVI) Scientific Initiatives Committee performed a global survey to evaluate the use of different cardiac imaging modalities for the evaluation of the right heart. METHODS AND RESULTS: Delegates from 250 EACVI registered centres were invited to participate in a survey which was also advertised on the EACVI bulletin and on social media. One hundred and thirty-eight respondents from 46 countries across the world responded to the survey. Most respondents worked in tertiary centres (79%) and echocardiography was reported as the commonest imaging modality used to assess the right ventricle (RV). The majority of survey participants (78%) included RV size and function in >90% of their echocardiographic reports. The RV basal diameter obtained from the apical four-chamber view and the tricuspid annular plane systolic excursion were the commonest parameters used for the echocardiographic assessment of RV size and function as reported by 82 and 97% respondents, respectively. Survey participants reported arrhythmogenic cardiomyopathy as the commonest condition (88%) where cardiac magentic resonance (CMR) imaging was used for right heart assessment. Only 52% respondents included RV volumetric and ejection fraction assessments routinely in their CMR reports, while 30% of respondents included these parameters only when RV pathology was suspected. Finally, 73% of the respondents reported pulmonary hypertension as the commonest condition where right heart catheterization was performed. CONCLUSION: Echocardiography remains the most frequently used imaging modality for the evaluation of the right heart, while the use of other imaging techniques, most notably CMR, is increasing.


Assuntos
Disfunção Ventricular Direita , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Ventrículos do Coração , Imagem Multimodal , Inquéritos e Questionários , Função Ventricular Direita , Reprodutibilidade dos Testes
6.
Eur Heart J Cardiovasc Imaging ; 23(5): 590-597, 2022 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-34957501

RESUMO

AIMS: The European Association of Cardiovascular Imaging (EACVI) Scientific Initiatives Committee performed a global survey to evaluate current practice for the assessment and management of patients with hypertrophic cardiomyopathy (HCM). METHODS AND RESULTS: A total of 213 centres from 38 different countries (87% European) responded to the survey. One hundred twenty-one (57%) centres followed HCM patients in a general cardiology outpatient clinic and 85 (40%) centres in a specialized HCM/cardiomyopathy clinic. While echocardiography was the primary imaging modality, cardiovascular magnetic resonance (CMR) has become an important complementary tool. Cardiac anatomy, left ventricular (LV) systolic, and diastolic function were assessed according to current European guidelines and recommendations. To evaluate LV obstruction, 49% of the centres performed bedside provocation manoeuvres in every patient and 55% of the centres used exercise stress echocardiography. The majority of centres used the 5-year risk assessment of sudden cardiac death (SCD) calculated with the HCM Risk-SCD score. However, 34% of the centres also used extensive non-infarct late gadolinium enhancement on CMR and 27% the presence of LV apical aneurysm to help select patients for primary prevention implantable cardioverter-defibrillator therapy. Ninety-nine percent of the responding centres performed regular imaging follow-up of HCM patients. CONCLUSION: Most centres followed European guidelines and recommendations for the diagnosis and management of patients with HCM. The importance of bedside provocation manoeuvres and exercise stress echocardiography to diagnose LV outflow obstruction requires emphasis. Additional risk markers for SCD are used in many centres and might indicate the need for an update of current European recommendations.


Assuntos
Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/terapia , Meios de Contraste , Morte Súbita Cardíaca/prevenção & controle , Gadolínio , Humanos , Medição de Risco/métodos , Fatores de Risco
7.
J Am Soc Echocardiogr ; 35(5): 469-476, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34933117

RESUMO

BACKGROUND: In hypertrophic cardiomyopathy (HCM), one of the main pathophysiological features is diastolic dysfunction. According to the 2016 American Society of Echocardiography (ASE)/European Association of Cardiovascular Imaging (EACVI) recommendations, diastolic function is assessed with echocardiographic variables. However, the association between the ASE/EACVI recommendations and the outcome in patients with HCM remains unclear. We evaluated the prognostic implications of the ASE/EACVI recommendations in patients with HCM. METHODS: This study included 290 patients with HCM. We evaluated four variables for identifying diastolic dysfunction using the following abnormal cutoff values: septal e' < 7 cm/sec, septal E/e' ratio > 15, left atrial volume index > 34 mL/m2, and peak tricuspid regurgitation velocity > 2.8 m/sec. A score was developed in which one point was designated for each abnormal echo parameter of diastolic function. We divided patients into two groups with an ASE/EACVI score of 3 as the cutoff value. The primary endpoint was the combination of HCM-related adverse outcomes (combination of sudden death or potentially lethal arrhythmic events, heart failure-related death, and heart failure hospitalization). RESULTS: The prevalence of an ASE/EACVI score ≥3 was 37.2%. Over a median follow-up of 9.7 (6.9-12.9) years, 26 (24.1%) patients with an ASE/EACVI score ≥3 and 25 (13.7%) patients with an ASE/EACVI score <3 experienced a combination of HCM-related adverse outcomes. Patients with an ASE/EACVI score ≥3 had a significantly higher incidence of the combined endpoint than those with an ASE/EACVI score <3 (log-rank, P = .010). An ASE/EACVI score ≥3 was an independent determinant of the combined endpoint in multivariate analysis (adjusted hazard ratio = 1.92; 95% CI, 1.05-3.49; P = .033). CONCLUSIONS: The score for identifying diastolic dysfunction by following ASE/EACVI recommendations may be associated with an adverse outcome in patients with HCM.


Assuntos
Cardiomiopatias , Cardiomiopatia Hipertrófica , Insuficiência Cardíaca , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Diástole , Ecocardiografia , Humanos , Prognóstico , Estados Unidos/epidemiologia , Função Ventricular Esquerda/fisiologia
8.
Caspian J Intern Med ; 12(4): 586-592, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34820067

RESUMO

BACKGROUND: Few studies have used the 2016 American Society of Echocardiography/ European Association of Cardiovascular Imaging (ASE/EACVI) guidelines to detect left ventricular diastolic dysfunction (LVDD) among asymptomatic normotensive type 2 diabetes mellitus (T2DM) patients. METHODS: 200 asymptomatic non-hypertensive diabetic cases and 281 controls matched for age and body mass index without evidence of arrhythmias, valvular, myocardial, pericardial or coronary artery disease underwent diastology assessment using 2 dimensional and M-mode echocardiography along with tissue Doppler imaging. RESULTS: The presence of LVDD was seen to be significantly higher among the members of the diabetic group compared to the controls (35 vs. 14; P=0.001). The diabetics with LVDD had a longer duration of diabetes {8.04±7.75 vs. 5.27±5.49 years; P=0.04}, along with higher glycated hemoglobin (HbA1c) {8.40±1.38 vs. 7.80±1.60% ; P=0.05}, fasting blood glucose (FBS) {211.35±78.15 vs. 187.89±107.90 mg/dL; P=0.009, 2 hour post prandial blood glucose} (PPBS) {237.89±107.9 vs. 211.35±78.15 mg/dL; P=0.04}, serum triglyceride (TG) {246.91±171.82 vs. 163.44±99.37 mg/dL; P=0.008} yet had lower serum very low density lipoprotein levels (VLDL) {19.74±15.01 vs. 27.61±17.89 mg/dL; P=0.01}. CONCLUSION: This is one of the few studies so far to have demonstrated a higher occurrence of LVDD specifically among asymptomatic normotensive T2DM patients using the 2016 ASE/EACVI guidelines.

9.
Eur Heart J Cardiovasc Imaging ; 22(9): 959-960, 2021 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-34164650

RESUMO

The Food and Drug Administration alert enhances our understanding of the mechanism of severe reactions to ultrasound-enhancing agents (UEAs). The known incidence of these reactions remains low and unchanged (1 in 10 000 administrations). Because the risk-to-benefit ratio for ultrasound contrast agents (UCAs) remains extremely low, we do not advise any changes to laboratory policy regarding indications for their use. The use of these agents should continue in situations where they have been shown to be impactful. Lipid-based UCAs (SonoVue and Luminity) are contraindicated in patients who have a history of prior hypersensitivity to these UEAs, to polyethylene glycol (PEG) (macrogol), or to PEG-containing products, such as certain bowel preps for colonoscopy or laxatives.


Assuntos
Meios de Contraste , Polietilenoglicóis , Colonoscopia , Meios de Contraste/efeitos adversos , Humanos , Polietilenoglicóis/efeitos adversos , Ultrassonografia
10.
Eur Heart J Cardiovasc Imaging ; 22(10): 1098-1105, 2021 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-33969402

RESUMO

AIMS: The aim of this study is to analyse how current recommendations on left ventricular (LV) diastolic function assessment have been adopted. Identifying potential discrepancies between recommendations and everyday clinical practice would enable us to better understand and address the remaining challenges in this controversial and complex field. METHODS AND RESULTS: A total of 93 centres, mainly from tertiary care settings, responded to the survey. More than three-quarters (77%) of centres follow the 2016 ASE/EACVI recommendations for LV diastolic function evaluation in patients with preserved ejection fraction based upon e', E/e', tricuspid regurgitation velocity, and left atrial (LA) volume. These recommendations were generally preferred to the previous 2009 version. Many centres also consider strain assessments in the LV (48%) and left atrium (53%) as well as diastolic stress echocardiography (33%) to be useful as additional assessments of LV diastolic function. Echocardiographic assessments of LV diastolic function were used frequently to guide therapy in 72% of centres. CONCLUSION: There is widespread adoption of current recommendation on the evaluation of LV diastolic function and these are frequently used to guide patient management. Many centres now also consider LV and LA strain assessments useful in the clinical assessment of diastolic function. These may be considered in future recommendations.


Assuntos
Disfunção Ventricular Esquerda , Diástole , Ecocardiografia , Humanos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda
11.
Eur Heart J Cardiovasc Imaging ; 22(2): 135-141, 2021 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-33346351

RESUMO

AIMS: The European Association of Cardiovascular Imaging (EACVI) Scientific Initiatives Committee performed a global survey to evaluate the current practice for the assessment and management of patients with suspected patent foramen ovale (PFO) and cryptogenic stroke. METHODS AND RESULTS: In total, 79 imaging centres from 34 countries across the world responded to the survey, which comprised 17 questions. Most non-invasive investigations for PFO were widely available in the responding centres, with the exception of transcranial colour Doppler which was only available in 70% of sites, and most commonly performed by neurologists. Standard transthoracic echocardiography, with or without bubbles, was considered the first-level test for suspected PFO in the majority of the centres, whereas transoesophageal echocardiography was an excellent second-level modality. Most centres would rule out atrial fibrillation (AF) as a source of embolism in all patients with cryptogenic stroke (63%), with the remainder reserving investigation for patients with multiple AF risk factors (33%). Cardiac magnetic resonance was the preferred tool for identifying other unusual aetiologies, like cardiac masses or thrombi. After PFO closure, there was variation in the use of antiplatelet therapy: a quarter recommended treatment for life, while only 12% recommended 5 years as stipulated in the guidelines (12%). Antibiotic prophylaxis prior to dental or endoscopic procedures was not recommended in 41% of centres, contrary to what the guidelines recommended. CONCLUSION: Our survey revealed a variable adherence to the current recommendations for the diagnosis and management of patients with cryptogenic stroke and PFO. Efforts should focus on optimizing and standardizing diagnostic tests and treatment of this condition.


Assuntos
Fibrilação Atrial , Forame Oval Patente , AVC Isquêmico , Acidente Vascular Cerebral , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/epidemiologia , Humanos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
12.
Eur Heart J Cardiovasc Imaging ; 22(1): 1-7, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33165600

RESUMO

AIMS: The European Association of Cardiovascular Imaging (EACVI) Scientific Initiatives Committee performed a global survey to evaluate current practice for the assessment and management of patients with suspected and confirmed chronic coronary syndromes. METHODS AND RESULTS: One-hundred and ten imaging centres from 37 countries across the world responded to the survey. Most non-invasive investigations for coronary artery disease were widely available, except cardiovascular magnetic resonance (available 40% centres). Coronary computed tomography angiography (CCTA) and nuclear scans were reported by a multi-disciplinary team in only a quarter of centres. In the initial assessment of patients presenting with chest pain, only 32% of respondents indicated that they rely on pre-test probability for selecting the optimal imaging test while 31% proceed directly to CCTA. In patients with established coronary artery disease and recurrent chest pain, respondents opted for stress echocardiography (27%) and nuclear stress perfusion scans (26%). In asymptomatic patients with coronary artery disease and an obstructive (>70%) right coronary artery stenosis, 58% of respondents were happy to pursue medical therapy without further testing or intervention. This proportion fell to 29% with left anterior descending artery stenosis and 1% with left main stem obstruction. In asymptomatic patients with evidence of moderate-to-severe myocardial ischaemia (15%), only 18% of respondents would continue medical therapy without further investigation. CONCLUSION: Despite guidelines recommendations pre-test probability is used to assess patients with suspected coronary artery in a minority of centres, one-third of centres moving directly to CCTA. Clinicians remain reticent to pursue a strategy of optimal medical therapy without further investigation or intervention in patients with controlled symptoms but obstructive coronary artery stenoses or myocardial ischaemia.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Inquéritos e Questionários , Síndrome
13.
Eur Heart J Cardiovasc Imaging ; 21(8): 828-832, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32361725

RESUMO

AIMS: To evaluate the diagnosis and imaging of patients with suspected endocarditis and the management in routine clinical practice across Europe, the EACVI Scientific Initiatives Committee performed a survey across European centres. In particular, the routine use of echocardiography, advanced imaging modalities and multidisciplinary team was explored. METHODS AND RESULTS: A total of 100 European Echocardiography Laboratories from 29 different countries responded to the survey, which consisted of 20 questions. For most of the use of echocardiography and advanced imaging, answers from the centres were relatively homogeneous and demonstrated good adherence to current recommendations. In particular, two-thirds of centres report the use of a specific endocarditis team for decision-making. Echocardiography plays a key role in the diagnosis and management of endocarditis. Nuclear imaging modalities are broadly available among the centres and are mainly used in prosthetic valve endocarditis and cardiac device-related infective endocarditis. Computed tomography (CT) is widely available and used to assess for structural valve abnormalities, neurological complications, and to preoperative assessment of the coronary arteries. Most institutions provide structured patients follow-up following hospital discharge. CONCLUSION: In Europe, a relatively homogenous adherence to current recommendation was observed for most diagnostic and management including the follow-up of patients with endocarditis. Decision-making is most commonly performed by a multidisciplinary team. Echocardiography remains the first line and central imaging modality for patient diagnosis and assessment, but 60% of centres also commonly use CT, whilst positron emission tomography imaging is used in patients with prosthetic valve endocarditis or device infection.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Endocardite/diagnóstico por imagem , Endocardite/terapia , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/tratamento farmacológico , Endocardite Bacteriana/epidemiologia , Europa (Continente) , Humanos , Tomografia por Emissão de Pósitrons , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/terapia
14.
Echocardiography ; 37(4): 546-553, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32298005

RESUMO

OBJECTIVE: To evaluate the impact of 2016 ASE/EACVI guidelines on Diastolic Function (DF) reporting during routine clinical practice. METHODS: Transthoracic echos performed 9 months before and 18 months after the 2016 guidelines (DF2016) were retrospectively analyzed. RESULTS: Twenty thousand eight hundred forty three echos performed between July 1, 2015, and September 30, 2017, were analyzed. Quarterly trends showed a stable proportion of normal DF (nDF), diastolic dysfunction (DD), indeterminate DF (DF-I), and nonreported DF (DF-NR) for 3 quarters preceding DF2016. After DF2016 release, reporting of DD decreased by 57% (P < .001), nDF increased by 76% (P < .001), DF-NR increased by 266% (P < .001), and DF-I did not change significantly (P = .40). Grade 1 DD decreased by 64% (P < .001), grade 2 DD decreased by 51% (P < .001), and grade 3 DD did not change significantly (P = .18). Provider level analysis showed increased heterogeneity in grade 1 DD reporting and decreased heterogeneity in DD grades 2 or higher, after DF2016. Systolic dysfunction reporting remained relatively stable (22%→21%→20%) compared to a significant decrease in isolated DD (35%→21%→10%). CONCLUSION: The 2016 guidelines update has impacted DF reporting patterns significantly. The likelihood of reporting DD decreased significantly, especially for grades 1 and 2. Inter-provider heterogeneity in DF reporting improved for grades 2 and 3 but worsened for grade 1. There was more than threefold increase in failure to report DF, suggesting a decrease in provider confidence.


Assuntos
Disfunção Ventricular Esquerda , Diástole , Ecocardiografia , Sopros Cardíacos , Humanos , Estudos Retrospectivos , Disfunção Ventricular Esquerda/diagnóstico por imagem
15.
Eur Heart J Cardiovasc Imaging ; 21(4): 357-362, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32196100

RESUMO

Aortic stenosis (AS) is the most prevalent valvular disease in developed countries, with a prevalence that is set to expand further with an ageing population. The most recent guidelines on valvular heart disease published by the European Society of Cardiology and the European Association for Cardio-Thoracic Surgery, aim to standardize the diagnosis and management of valvular heart diseases. The imaging criteria of the current guidelines are mostly based on EACVI Recommendations, with an appropriate diagnostic workflow being of major importance, to ensure streamlined and efficient patient assessment and accurate diagnoses and decisions regarding the timing of surgery. The EACVI Scientific Initiatives Committee, therefore, created a survey on the imaging assessment of patient with AS to investigate the diagnostic patient pathways used in different centres across Europe. In particular, we conducted this survey to better understand the use and access of advanced imaging techniques in AS including 3D transthoracic echocardiography and 3D transoesophageal echocardiography, cardiac computed tomography, and cardiovascular magnetic resonance.


Assuntos
Estenose da Valva Aórtica , Cardiologia , Cirurgia Torácica , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Europa (Continente) , Humanos , Sociedades Médicas
16.
Eur Heart J Cardiovasc Imaging ; 21(2): 119-123, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31819943

RESUMO

AIMS: To evaluate standard reporting of cardiac chambers size and function by transthoracic echocardiography (TTE), the EACVI Scientific Initiatives Committee performed a survey across European centres. In particular, the routine use of three-dimensional echocardiography (3DE) and speckle tracking-derived myocardial deformation imaging (STE) was explored. METHODS AND RESULTS: A total of 96 European Echocardiography Laboratories from 22 different countries responded to the survey, which consisted of 20 questions. For most of the standard parameters of cardiac chamber size and function, answers from the centres were homogeneous and demonstrated good adherence to current recommendations. In particular, all centres assessed left ventricular (LV) and left atrial (LA) size combining diameter measurements with volumes obtained using the bi-plane Simpson's method. More variability was observed in the measurements of the right heart chambers and thoracic aorta. Interestingly, >90% of centres had access to 3DE and STE; however, the large majority of centres reserved the use of these techniques for selected cases, particularly for the measure of 3D LV volumes and ejection fraction and global longitudinal strain in patients being considered for cardiac device implantation, surgical intervention (valvular heart disease) or screened for cardiotoxicity. Only 10% of centres used 3DE for right ventricular and LA volumes. Also, <30% of the centres used LA strain imaging. CONCLUSION: In Europe, a good adherence to current recommendations was observed for most of the standard parameters of cardiac chambers quantification by TTE. Advanced echocardiography modalities, such as 3DE and STE, are widely available but used only in selected cases.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia , Europa (Continente) , Ventrículos do Coração/diagnóstico por imagem , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Volume Sistólico , Função Ventricular Esquerda
17.
JACC CardioOncol ; 2(5): 677-689, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34396282

RESUMO

Echocardiographic imaging is crucial for patient management during cardiotoxic cancer therapy. Left ventricular ejection fraction is the most commonly used parameter for identifying left ventricular dysfunction. However, it lacks sensitivity to detect subclinical changes in cardiac function due to cardiotoxic treatment. Global longitudinal strain (GLS) is the best studied strain parameter with established diagnostic and prognostic value. Multiple studies have demonstrated changes in GLS as an early marker of cardiotoxicity. This document serves as a primer to help clinicians in the acquisition and interpretation of strain in cardio-oncology. Cases with embedded videos illustrate a step-by-step approach to obtaining GLS measurements and common pitfalls to avoid. The document includes a concise summary of the indications of GLS in cardio-oncology and its role in guiding oncological therapy. Practical approaches on how to implement strain in the echo laboratory with guidance on training and quality assurance are also discussed.

18.
Eur Heart J Cardiovasc Imaging ; 20(12): 1332-1336, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31750533

RESUMO

One of the missions of the European Association of Cardiovascular Imaging (EACVI) is 'to promote excellence in clinical diagnosis, research, technical development, and education in cardiovascular imaging'. The future of imaging involves multimodality so each imager should have the incentive and the possibility to improve its knowledge in other cardiovascular techniques. This article presents the results of a 20 questions survey carried out in cardiovascular imaging (CVI) centres across Europe. The aim of the survey was to assess the situation of experience and training of CVI in Europe, the availability and organization of modalities in each centre and to ask for vision about potential improvements in CVI at national and European level.


Assuntos
Imagem Multimodal , Europa (Continente) , Humanos , Inquéritos e Questionários
19.
Eur Heart J Cardiovasc Imaging ; 20(9): 963-966, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31436816

RESUMO

The European Association of Cardiovascular Imaging (EACVI) is committed to maintaining the highest standards of professional excellence in all aspects of cardiovascular imaging. The mission of the EACVI is to promote excellence in clinical diagnosis, research, technical development, and education in cardiovascular imaging with a particular focus on education, training, scientific initiatives, and research. The EACVI established the Scientific Initiatives Committee (SIC) in December 2018. This committee has responsibility for surveys among imagers, patients' surveys and surveys including data from clinical practice. The current document describes the aims of the EACVI SIC and the creation of the international EACVI survey network. This document summarizes the EACVI's standards for the survey questions and standards for writing the papers with the results of the surveys. These are in accordance with previous recommendations and were approved by the EACVI SIC and the EACVI Board in 2019.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Inquéritos e Questionários/normas , Europa (Continente) , Humanos , Objetivos Organizacionais , Sociedades Médicas
20.
Scand Cardiovasc J ; 53(6): 312-316, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31328575

RESUMO

Objectives. To compare the ability of the E/a' ratio and the recommended diastolic parameters in the American Society of Echocardiography (ASE) and the European Association of Cardiovascular Imaging (EACVI), in predicting a dominant diastolic pulmonary vein flow in patients with normal ejection fraction. Design. We retrospectively evaluated the diastolic function according to the ASE/EACVI guidelines, the S/D ratio and the septal, lateral and average E/a' ratio in 293 unselected in-hospital patients, aged 39-86 years, in sinus rhythm and with no or mild valve disease, having a normal systolic function (EF > 50%). Results. The S/D ratio had a positive association to septal, lateral and average E/a ratio (R2 = 0.25, 0.35 and 0.32). The association to average E/e' ratio, LA vol index and TR velocity was weak (R2 = 0.037, 0.033 and 0.087) and for e' velocity negatively. In patients with S/D ratio <1, septal, lateral, average E/a' ratio, average E/e ratio, LA vol index (p<.001) and TR velocity (p<.05) were significantly higher compared to patients with S/D ratio ≥1. No significant difference was seen in e' velocity. The septal, lateral and average E/a' ratio were significantly higher in patients with S/D ratio <1 regardless a normal or impaired diastolic function according to the ASE/EACVI guidelines (p<.001). The ASE/EACVI algorithm detected 21 patients with S/D ratio <1 compared to 28 patients using average E/a' ratio with cut-off >14. Conclusion: E/a' ratio might be a useful new diastolic parameter in patients with a normal ejection fraction as it is more closely related to the S/D ratio than the established ASE/EACVI diastolic parameters.


Assuntos
Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Adulto , Idoso , Idoso de 80 Anos ou mais , Diástole , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA