Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 247
Filtrar
1.
Chemosphere ; 363: 142873, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39019187

RESUMO

Electro-osmosis has been valued as a promising technology to enhance the dewatering of waste sludge, stabilization and environmental remediation of soils with low permeability. However, the coefficient of electro-osmotic permeability (keo) is commonly taken as constant value which is particularly not the case in variable charge soil. As a result, the nonlinearity of the electro-osmotic flow (EOF) and the direction reverse could not be interpreted. Herein, the electro-chemical parameters were monitored in electro-osmotic experiment with natural variable charge soil. It was observed that the evolutions showed significant nonlinear behavior and were correlated. The comprehensive Zeta potential model proposed by the authors was applied to simulate the nonlinear keo induced by the variable pH and electrolyte concentration. The agreement between tested and simulated flow rate variation and excess pore water pressure distribution demonstrated the reliability of the theory. The error rate of the simulations through coupling nonlinear keo and voltage gradient Ex was reduced to 29.4% from 381.9% of calculations with constant parameters. The direction reverse of EOF was innovatively interpreted. Hence, the numerical model would act as a useful tool to connect these electro-chemical parameters and provide guidance to evaluate contributions of commonly used pH conditioning measurements.

2.
Artigo em Inglês | MEDLINE | ID: mdl-39038810

RESUMO

Biological and solid-state nanopores are at the core of transformative techniques and nanodevices, democratizing the examination of matter and biochemical reactions at the single-molecule level, with low cost, portability, and simplicity in operation. One of the crucial hurdles in such endeavors is the fast analyte translocation, which limits characterization, and a rich number of strategies have been explored over the years to overcome this. Here, by site-directed mutagenesis on the α-hemolysin protein nanopore (α-HL), sought to replace selected amino acids with glycine, electrostatic binding sites were induced on the nanopore's vestibule and constriction region and achieved in the most favorable case a 20-fold increase in the translocation time of short single-stranded DNA (ssDNA) at neutral pH, with respect to the wild-type (WT) nanopore. We demonstrated an efficient tool of controlling the ssDNA translocation time, via the interplay between the nanopore-ssDNA surface electrostatic interactions and electroosmotic flow, all mediated by the pH-dependent ionization of amino acids lining the nanopore's translocation pathway. Our data also reveal the nonmonotonic, pH-induced alteration of ssDNA average translocation time. Unlike mildly acidic conditions (pH ∼ 4.7), at a pH ∼ 2.8 maintained symmetrically or asymmetrically across the WT α-HL, we evidenced the manifestation of a dominant electroosmotic flow, determining the speeding up of the ssDNA translocation across the nanopore by counteracting the ssDNA-nanopore attractive electrostatic interactions. We envision potential applications of the presented approach by enabling easy-to-use, real-time detection of short ssDNA sequences, without the need for complex biochemical modifications to the nanopore to mitigate the fast translocation of such sequences.

3.
ACS Nano ; 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39051760

RESUMO

Nanopore technology is widely used for sequencing DNA, RNA, and peptides with single-molecule resolution, for fingerprinting single proteins, and for detecting metabolites. However, the molecular driving forces controlling the analyte capture, its residence time, and its escape have remained incompletely understood. The recently developed Nanopore Electro-Osmotic trap (NEOtrap) is well fit to study these basic physical processes in nanopore sensing, as it reveals previously missed events. Here, we use the NEOtrap to quantitate the electro-osmotic and electrophoretic forces that act on proteins inside the nanopore. We establish a physical model to describe the capture and escape processes, including the trapping energy potential. We verified the model with experimental data on CRISPR dCas9-RNA-DNA complexes, where we systematically screened crucial modeling parameters such as the size and net charge of the complex. Tuning the balance between electrophoretic and electro-osmotic forces in this way, we compare the trends in the kinetic parameters with our theoretical models. The result is a comprehensive picture of the major physical processes in nanopore trapping, which helps to guide the experiment design and signal interpretation in nanopore experiments.

4.
Nano Lett ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38949896

RESUMO

Recent years have seen a growing interest in zero-dimensional (0D) transport phenomena occurring across two-dimensional (2D) materials for their potential applications to nanopore technology such as ion separation and molecular sensing. Herein, we investigate ion transport through 1 nm-wide nanopores in Ti3C2 MXene using molecular dynamics simulations. The high polarity and fish-bone arrangement of the Ti3C2 MXene offer a built-in potential and an atomic-scale distortion to the nanopore, causing an adsorption preference for cations. Our observation of variable cation-specific ion selectivity and Coulomb blockade highlights the complex interplay between adsorption affinity and cation size. The cation-specific ion selectivity can induce both the ion current and electro-osmotic water transmission, which can be regulated by tailoring the ions' preferential pathways through electric field tilting. Our finding underscores the pivotal role of the atomic arrangement of MXenes in 0D ion transport and provides fundamental insight into the application of 2D material in nanopores-based technologies.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38877193

RESUMO

Dredging eutrophic lake sediments can improve water quality, but it also requires dewatering and valorizing the dredged material to avoid wasting resources like phosphorus. This study experimentally investigated the basic mechanism and performance of electroosmotic dewatering of 1-L dredged sediments using different electric currents (20 mA, 40 mA, and 60 mA) after gravity filtration. The dewatering performance, moisture content and distribution, effect of electrochemical reaction on dewaterability, energy consumption, and changes in metals and phosphorus (P) distribution and pH values were analyzed. The results indicated that electroosmotic dewatering effectively decreased sediment mass by predominantly eliminating free and a portion of interstitial water, with reductions ranging from 7 to 20%. The optimal duration and current should, however, be considered to balance water removal and energy consumption. Higher moisture removal occurred with 40 mA for 24 h and 60 mA for 6 h, while the energy consumption obtained with 60 mA (0.201 kWh/kg water removed) was significantly lower than that of applying 40 mA for 24 h (0.473 kWh/kg water removed), with the assistance of ohmic heating, resulting in reduced viscosity and water release from capillaries. The tested conditions did not significantly extract heavy metals or P from the sediments, which may facilitate the disposal of the removed water back into the lake and the utilization of the treated sediments for different purposes. This technology is easy to operate and suitable for the treatment of dredged sediments, and the dewatering result is comparable to low pressurized filtration but at low energy consumption.

6.
Chemosphere ; 361: 142503, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38825242

RESUMO

There is considerable interest in addressing soils contaminated with per- and polyfluoroalkyl substances (PFAS) because of the PFAS in the environment and associated health risks. The neutralization of PFAS in situ is challenging. Consequently, mobilizing the PFAS from the contaminated soils into an aqueous solution for subsequent handling has been pursued. Nonetheless, the efficiency of mobilization methods for removing PFAS can vary depending on site-specific factors, including the types and concentrations of PFAS compounds, soil characteristics. In the present study, the removal of perfluorooctanoate (PFOA) and perfluorooctane sulfonate (PFOS) from artificially contaminated soils was investigated in a 2D laboratory setup using electrokinetic (EK) remediation and hydraulic flushing by applying a hydraulic gradient (HG) for a duration of 15 days. The percent removal of PFOA by EK was consistent (∼80%) after a 15-day treatment for all soils. The removal efficiency of PFOS by EK significantly varied with the OM content, where the PFOS removal increased from 14% at 5% OM to 60% at 50% OM. With HG, the percent removal increased for both PFOA and PFOS from about 20% at 5% OM up to 80% at 75% OM. Based on the results, the mobilization of PFAS from organic soil would be appropriate using both hydraulic flushing and EK considering their applicability and advantages over each other for site-specific factors and requirements.


Assuntos
Ácidos Alcanossulfônicos , Caprilatos , Fluorocarbonos , Poluentes do Solo , Solo , Fluorocarbonos/análise , Fluorocarbonos/química , Poluentes do Solo/análise , Solo/química , Ácidos Alcanossulfônicos/análise , Ácidos Alcanossulfônicos/química , Caprilatos/análise , Caprilatos/química , Recuperação e Remediação Ambiental/métodos
7.
Adv Mater ; : e2401761, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38860821

RESUMO

Nanopores are powerful tools for single-molecule sensing of biomolecules and nanoparticles. The signal coming from the molecule to be analyzed strongly depends on its interaction with the narrower section of the nanopore (constriction) that may be tailored to increase sensing accuracy. Modifications of nanopore constriction have also been commonly used to induce electroosmosis, that favors the capture of molecules in the nanopore under a voltage bias and independently of their charge. However, engineering nanopores for increasing both electroosmosis and sensing accuracy is challenging. Here it is shown that large electroosmotic flows can be achieved without altering the nanopore constriction. Using continuum electrohydrodynamic simulations, it is found that an external charged ring generates strong electroosmosis in cylindrical nanopores. Similarly, for conical nanopores it is shown that moving charges away from the cone tip still results in an electroosmotic flow (EOF), whose intensity reduces increasing the diameter of the nanopore section where charges are placed. This paradigm is applied to engineered biological nanopores showing, via atomistic simulations and experiments, that mutations outside the constriction induce a relatively intense electroosmosis. This strategy provides much more flexibility in nanopore design since electroosmosis can be controlled independently from the constriction, which can be optimized to improve sensing accuracy.

8.
Chemosphere ; 362: 142661, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38906191

RESUMO

Electro-osmosis offers an effective method for dewatering and remediating low permeability soil. Long-term observations on nonlinear behavior of electro-osmosis and the influencing factors are not commonly reported. Connection between cessation and direction reversal of electro-osmotic flow (EOF), and the evolution of electro-chemical parameters inside of the soil mass thus remains unclear. The dynamic response of EOF in variable charge soil could be significant, whereas the investigations on which are currently lacking. A series of electro-osmotic experiments were performed with two natural variable charge soils. The results indicated that initial electro-osmotic rate was positively proportional to electric current and initial electrical conductivity of the pore fluid, which could be explained by the ion migration model. The dynamic evolution of electro-osmotic rate and electro-chemical parameters corresponding to the solute and pH conditionings at the electrode compartments demonstrated that: 1) coupling effects of non-uniform distribution of voltage gradient and pH determined the magnitude and direction of EOF rate; 2) compared to the final pHIEP value, the bigger, close and smaller values of the novel index "voltage gradient weighed mean of spatial pH″ represented the forward, terminated and reversed EOF respectively; 3) the classical Helmholtz-Smoluchowski model are proved to be more applicable interpreting the coupled nonlinearity of electro-osmosis during the later steady phase. This work would facilitate future research for a comprehensive electro-osmotic model, and provide guidance to condition the initial and boundary conditions in application of electro-osmotic dewatering and electrokinetic remediation.

9.
Micromachines (Basel) ; 15(5)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38793226

RESUMO

Surface plasmon resonance (SPR) has been extensively employed in biological sensing, environmental detection, as well as chemical industry. Nevertheless, the performance possessed by conventional surface plasmon resonance (SPR) biosensors can be further limited by the transport of analyte molecules to the sensing surface, noteworthily when small molecules or low levels of substances are being detected. In this study, a rapid and highly sensitive SPR biosensor is introduced to enhance the ability of the target analytes' collection by integrating AC electroosmosis (ACEO) and dielectrophoresis (DEP). Both the above-mentioned phenomena principally arise from the generation of the AC electric fields. This generation can be tailored by shaping the interdigitated electrodes (IDEs) that also serve as the SPR biomarker sensing area. The effects exerted by different parameters (e.g., the frequency and voltage of the AC electric field as well as microelectrode structures) are considered in the iSPR (interdigitated SPR) biosensor operation, and the iSPR biosensors are optimized with the sensitivity. The results of this study confirm that the iSPR can efficiently concentrate small molecules into the SPR sensing area, such that SPR reactions achieve an order of magnitude increase, and the detection time is shortened. The rapid and sensitive sensor takes on critical significance in the development of on-site diagnostics in a wide variety of human and animal health applications.

10.
Chemosphere ; 358: 142265, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38719121

RESUMO

Electro-dewatering of sewage sludge with pulsating voltage was conducted under the two different wave shapes (square wave (SQW) and half-sine wave (HSW)) to investigate the influence of wave shape and duty cycle on sludge dewatering performance. The results indicated that, under the same average voltage, the moisture content of dewatered sludge with HSW was 10.3%-35.4% lower than that with SQW, suggesting the better dewatering performance of HSW. The optimal dewatering performance was achieved at duty cycle of 80% for SQW and 60% for SHW. The chemical oxygen demand of filtrate from HSW could be 13% higher than that from SQW, indicating the higher capacity of HSW in breaking sludge cells/floc structure. The applied voltage during electrochemical treatment promoted the hydrolysis of protein in filtrate, and the main components in the electro-dewatered filtrate were fulvic acid- and humic acid-like substances. The specific energy consumption for sludge electro-dewatering were 0.015-0.269 kWh/(kg removed water), and it was almost in linear relationship with duty cycle. By overall considering the energy consumption and electro-dewatering performance, the condition of 60% duty cycle with HSW was obviously better than other conditions, which provides a meaningful guidance for future application of sludge electro-dewatering technology with pulsating voltage.


Assuntos
Esgotos , Eliminação de Resíduos Líquidos , Esgotos/química , Eliminação de Resíduos Líquidos/métodos , Análise da Demanda Biológica de Oxigênio , Técnicas Eletroquímicas/métodos , Substâncias Húmicas/análise , Água/química , Benzopiranos
11.
Pharmaceutics ; 16(4)2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38675200

RESUMO

Iontophoresis enables the non-invasive transdermal delivery of moderately-sized proteins and the needle-free cutaneous delivery of antibodies. However, simple descriptors of protein characteristics cannot accurately predict the feasibility of iontophoretic transport. This study investigated the cathodal and anodal iontophoretic transport of the negatively charged M7D12H nanobody and a series of negatively charged variants with single amino acid substitutions. Surprisingly, M7D12H and its variants were only delivered transdermally by anodal iontophoresis. In contrast, transdermal permeation after cathodal iontophoresis and passive diffusion was

12.
Heliyon ; 10(7): e28718, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38590885

RESUMO

The demand for innovative and cost-effective in-situ consolidation technologies in soft clay stimulated the effort to employ electrokinetic phenomena in soils under an electric field. This work explains the principles of electrophoresis and electroosmosis in soft clay under an electric field and discusses the implacations of these results for field implementation of the technique. The experimental work reported here was carried out to shed light on the principles by considering various influencing factors. The results show that there is a threshold current (about 15 mA) for electroosmosis and electrophoresis in soft clay. Below the threshold current, electrophoresis plays a major role and is accompanied by weak electroosmosis. The particle size, dry density, and boundary rise height of electrophoretic soil in anode chamber are mainly affected by soil moisture content, electrode in electrolyte length, and bottom of electrode to soil surface distance. The closer the soil moisture content is to the average value of the liquid limit and plastic limit, the denser the electrophoretic soil will be. Above the threshold current, almost only electroosmosis occurs. The greater the current, the greater the electroosmosis. In practical engineering application, electrodes are usually directly inserted into the soft clay. This results in the current usually being much greater than the threshold current, meaning the electrophoretic phenomenon in the soil can be negligible.

13.
J Colloid Interface Sci ; 665: 263-273, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38485631

RESUMO

HYPOTHESIS: Electronic paper displays rely on electrokinetic effects in nonpolar solvents to drive the displacement of colloidal particles within a fluidic cell. While Electrophoresis (EP) is a well-established and frequently employed phenomenon, electro-osmosis (EO), which drives fluid flow along charged solid surfaces, has not been studied as extensively. We hypothesize that by exploiting the interplay between these effects, an enhanced particle transport can be achieved. EXPERIMENTS: In this study, we experimentally investigate the combined effects of EP and EO for colloidal particles in non-polar solvents, driven by an electric field. We use astigmatism micro-particle tracking velocimetry (A-µPTV) to measure the motion of charged particles within model fluidic cells. Using a simple approach that relies on basic fluid flow properties we extract the contributions due to EP and EO, finding that EO contributes significantly to particle transport. The validity of our approach is confirmed by measurements on particles with different magnitudes of charge, and by comparison to numerical simulations. FINDINGS: We find that EO flows can play a dominant role in the transport of particles in electrokinetic display devices. This can be exploited to speed up particle transport, potentially yielding displays with significantly faster switching times.

14.
Biosensors (Basel) ; 14(3)2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38534219

RESUMO

The rotation of cells is of significant importance in various applications including bioimaging, biophysical analysis and microsurgery. Current methods usually require complicated fabrication processes. Herein, we proposed an induced charged electroosmosis (ICEO) based on a chip manipulation method for rotating cells. Under an AC electric field, symmetric ICEO flow microvortexes formed above the electrode surface can be used to trap and rotate cells. We have discussed the impact of ICEO and dielectrophoresis (DEP) under the experimental conditions. The capabilities of our method have been tested by investigating the precise rotation of yeast cells and K562 cells in a controllable manner. By adjusting the position of cells, the rotation direction can be changed based on the asymmetric ICEO microvortexes via applying a gate voltage to the gate electrode. Additionally, by applying a pulsed signal instead of a continuous signal, we can also precisely and flexibly rotate cells in a stepwise way. Our ICEO-based rotational manipulation method is an easy to use, biocompatible and low-cost technique, allowing rotation regardless of optical, magnetic or acoustic properties of the sample.


Assuntos
Eletricidade , Eletro-Osmose , Acústica , Eletrodos , Eletro-Osmose/métodos , Rotação , Humanos
15.
Electrophoresis ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38509871

RESUMO

Tween 20 is frequently added to particle suspensions for reducing the particle-wall adhesion and particle-particle aggregation in microfluidic devices. However, the influences of Tween 20 on the fluid and particle behaviors have been largely ignored. We present in this work the first experimental study of the effects of Tween 20 addition on the electrokinetic transport of fluids and particles in a polydimethylsiloxane microchannel. We find that adding 0.1% v/v Tween 20 to a buffer solution can significantly reduce the electroosmotic mobility as well as the electrokinetic and electrophoretic mobilities of polystyrene particles and yeast cells. Further increasing the Tween 20 concentration within the range typically used in microfluidic applications continues reducing these mobility values, but at a smaller rate. Our finding suggests that Tween 20 should be used with care in electrokinetic microdevices when the flow rate or particle/cell throughput is an important parameter.

16.
Heliyon ; 10(5): e27185, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38495186

RESUMO

The present study investigates the MHD electro-osmotic flow of entropy generation analysis for peristaltic movement in a nanofluid with temperature-dependent viscosity. Long wavelengths, i.e., The magnitude of a wave's energy corresponds directly to its frequency while being inversely related to its wavelength in terms of velocity, temperature, and concentration, govern and confine the flow stream in the laminar region. Ohmic heating and hall effects are also included. Graphs are used to obtain and examine numerical solutions for axial velocity, temperature, concentration, Bejan number, and entropy generation. The effects of this research can help to improve pumping and gastrointestinal movements in different engineering devices. Debye-Huckel and lubrication approximations are studied to access the Boltzmann distribution of electric potential across an electric double layer. The investigations of an existing model are important in illuminating the microfluidics machinery used at the micro level for various transport phenomena in which fluids as well as particles are transported together. The current study has many applications and can be further extended to a three-dimensional profile with appropriate modifications and assumptions. When studying entropy generation, it is essential to examine the irreversible factors, while also taking into account the velocity and thermal slip conditions at channel boundaries. Moreover, the concept of entropy generation holds significant importance in comprehending various biological phenomena. Hence, the current research holds promising implications for both industrial and medical fields. The entropy generation is minimum at left wall of the channel for negative values of Helmholtz-Smoluchowski velocity.

17.
Annu Rev Anal Chem (Palo Alto Calif) ; 17(1): 243-264, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38360552

RESUMO

Nonlinear electrokinetic phenomena offer label-free, portable, and robust approaches for particle and cell assessment, including selective enrichment, separation, sorting, and characterization. The field of electrokinetics has evolved substantially since the first separation reports by Arne Tiselius in the 1930s. The last century witnessed major advances in the understanding of the weak-field theory, which supported developments in the use of linear electrophoresis and its adoption as a routine analytical technique. More recently, an improved understanding of the strong-field theory enabled the development of nonlinear electrokinetic techniques such as electrorotation, dielectrophoresis, and nonlinear electrophoresis. This review discusses the operating principles and recent applications of these three nonlinear electrokinetic phenomena for the analysis and manipulation of particles and cells and provides an overview of some of the latest developments in the field of nonlinear electrokinetics.

18.
Heliyon ; 10(3): e25102, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38322951

RESUMO

In this study, the computational analysis of entropy generation optimization for synthetic cilia regulated ternary hybrid Jeffery nanofluid (Ag-Au-TiO2/PVA) flow through a peristaltic vertical channel with swimming motile Gyrotactic microorganisms is investigated. Understanding the intricate interaction of multiple physical phenomena in biomedical applications is essential for optimizing entropy generation and advancing microfluidic systems. The characteristics of nanofluid are explored for the electroosmotic MHD fluid flow in the presence of thermophoresis and Brownian motion, viscous dissipation, Ohmic heating and chemical reaction. Using the appropriate transformations, a set of ordinary differential equations are created from the governing partial differential equations. The resulting ODEs are numerically solved using the shooting technique using BVP5C in MATLAB after applying the long-wavelength and low Reynolds number approximation. The velocity, temperature, concentration, electroosmosis, and microorganism density profiles are analyzed graphically for different emerging parameters. Graphical investigation of engineering interest quantities like heat transfer rate, mass transfer rate, skin friction coefficient, and entropy generation optimization are also presented. It is observed that the rate of mass transfer increases for increasing thermophoretic parameter, while reverse effect is noted for Brownian motion parameter, Schmidt number, and chemical reaction number. The outcomes of present study can be pertinent in studying Cilia properties of respiratory tract, reproductive system, and brain ventricles.

19.
Electrophoresis ; 45(13-14): 1155-1170, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38115169

RESUMO

Drug delivery systems, where the nanofluid flow with electroosmosis and mixed convection can help in efficient and targeted drug delivery to specific cells or organs, could benefit from understanding the behavior of nanofluids in biological systems. In current work, authors have studied the theoretical model of two-dimensional ciliary flow of blood-based (Eyring-Powell) nanofluid model with the insertion of ternary hybrid nanoparticles along with the effects of electroosmosis, magnetohydrodynamics, thermal radiations, and mixed convection. Moreover, the features of entropy generation are also taken into consideration. The system is modeled in a wave frame with the approximations of large wave number and neglecting turbulence effects. The problem is solved numerically by using the shooting method with the assistance of computational software "Mathematica" for solving the governing equation. According to the temperature curves, the temperature will increase as the Hartman number, fluid factor, ohmic heating, and cilia length increase. It is also disclosed that ternary hybrid nanoparticles result in a change in flow rate when other problem parameters are varied, and the same is true for temperature graphs. Engineers and scientists can make better use of nanofluid-based cooling systems in electronics, automobiles, and industrial processes with the aid of the study's findings.


Assuntos
Convecção , Eletro-Osmose , Entropia , Eletro-Osmose/métodos , Nanopartículas/química , Modelos Teóricos , Nanotecnologia/instrumentação , Nanotecnologia/métodos , Hidrodinâmica , Sistemas de Liberação de Medicamentos/instrumentação
20.
Cardiovasc Eng Technol ; 15(2): 171-198, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38148470

RESUMO

PURPOSE: The electrokinetic process for streaming fluids in magnetic environments is emerging due to its immense applications in medical and biochemical industrial domains. In this context, our proposed model seeks to inquire into the hemodynamic characteristics of electro-magnetized blood blended with trihybrid nanoparticles circulation induced by electro-osmotic forces in an endoscopic charged arterial annular indented tract. This steaming model also invokes the consequences of variable Lorentz attractive force, buoyancy force, heat source, viscous and Joule warming, arterial wall properties, and sliding phenomena for featuring more realistic problems in blood flows. Different shapes of suspended trihybrid nanoparticles, such as spheres, bricks, cylinders, and platelets, are included in the model formation. Electro-magnetized modified hybrid nano-blood is an electro-conductive solution comprising blood as base fluid and magnetized trihybrid nanoparticles (copper, gold, and alumina). METHODS: Closed-form solution in terms of Bessel's functions is gotten for electro-osmotic potential due to the electric double layer (EDL). The homotopy perturbation methodology is implemented in order to track down the convergent series solutions of non-linear coupled flow equations being elicited. The physical attributes of distinct evolving parameters on the different dimensionless hemodynamic profiles and quantities of interest are elucidated evocatively via a sort of graphs and charts. RESULTS: The ancillary outcomes proved that the Debye-Hückel parameter and Helmholtz-Smoluchowski velocity have a dual impact on the ionized bloodstream. The bloodstream rapidity is alleviated/boosted for the assisting/opposing electroosmosis process. Cooling of ionized blood in the endoscopic arterial conduit is achieved with lower Hartmann numbers. Copper-gold-alumina/blood exhibits a superior heat transmission rate across the arterial wall than copper-gold-blood, copper-blood, and pure blood. Additionally, the contour topology for the bloodstream in the flow domain is briefly elaborated. The contour distribution is significantly amended due to the variant of the Debye-Hückel parameter. CONCLUSION: The model's new findings may be invaluable in electro-magneto-endoscopic operation, electro-magneto-treatment for cancer, surgical process, etc.


Assuntos
Artérias , Modelos Cardiovasculares , Humanos , Hemodinâmica , Endoscopia/instrumentação , Ouro/química , Velocidade do Fluxo Sanguíneo , Cobre/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA