RESUMO
BACKGROUND: Challenges persist regarding how to integrate computing effectively into the exam room, while maintaining patient-centered care. PURPOSE: Our objective was to evaluate a new exam room design with respect to the computing layout, which included a wall-mounted monitor for ease of (re)-positioning. METHODS: In a lab-based experiment, 28 providers used prototypes of the new and older "legacy" outpatient exam room layouts in a within-subject comparison using simulated patient encounters. We measured efficiency, errors, workload, patient-centeredness (proportion of time the provider was focused on the patient), amount of screen sharing with the patient, workflow integration, and provider situation awareness. RESULTS: There were no statistically significant differences between the exam room layouts for efficiency, errors, or time spent focused on the patient. However, when using the new layout providers spent 75% more time in screen sharing activities with the patient, had 31% lower workload, and gave higher ratings for situation awareness (14%) and workflow integration (17%). CONCLUSIONS: Providers seemed to be unwilling to compromise their focus on the patient when the computer was in a fixed position in the corner of the room and, as a result, experienced greater workload, lower situation awareness, and poorer workflow integration when using the old "legacy" layout. A thoughtful design of the exam room with respect to the computing may positively impact providers' workload, situation awareness, time spent in screen sharing activities, and workflow integration.