Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 250
Filtrar
1.
J Pharm Bioallied Sci ; 16(Suppl 3): S2100-S2102, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39346270

RESUMO

Background: To determine the amount of apical extrusion between various file systems during the retreatment procedure and to determine the effect of taper on the same. Materials and Method: Seventy mandibular extracted premolars were taken, and preparation was performed using a Woodpecker file (Woodpecker Medical Instrument Co., Ltd., Guilin, China) (25/0.06). The gutta-percha (GP) was removed from each specimen with H file (#40/0.02) to simulate retreatment in seven groups (n = 10) using ProTaper Next (PTN;Dentsply, Maillefer, Ballaigues, Switzerland) (PTN) (30/0.07), Reciproc (25/0.08), Hyflex CM (30/0.06), Mtwo (30/0.05), Neoendo flex (30/0.04), Neoendo hybrid (30/0.04), and Flexicon file (30/0.06). The specimens were held with the help of a rubber stopper and put in the Eppendorf tube of volume 4 mL (pre-weighed before retreatment). The debris that was on the root surface of the specimen was washed with distilled water with 1 mL volume, kept in the oven, and then again weighed after 7 days. Results: Apical extrusion was found in the following order: HYFLEX CM (LEAST) < FLEXICON < PROTAPER NEXT < RECIPROC < NEOENDO FLEX < NEOENDO HYBRID < MTWO (HIGHEST). Conclusion: W Hyflex CM and Flexicon files showed lesser extrusion of debris than others.

2.
Proteins ; 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39264222

RESUMO

Considering p53's pivotal role as a tumor suppressor protein, proactive identification and characterization of potentially harmful p53 mutations are crucial before they appear in the population. To address this, four computational prediction tools-SIFT, Polyphen-2, PhD-SNP, and MutPred2-utilizing sequence-based and machine-learning algorithms, were employed to identify potentially deleterious p53 nsSNPs (nonsynonymous single nucleotide polymorphisms) that may impact p53 structure, dynamics, and binding with DNA. These computational methods identified three variants, namely, C141Y, C238S, and L265P, as detrimental to p53 stability. Furthermore, molecular dynamics (MD) simulations revealed that all three variants exhibited heightened structural flexibility compared to the native protein, especially the C141Y and L265P mutations. Consequently, due to the altered structure of mutant p53, the DNA-binding affinity of all three variants decreased by approximately 1.8 to 9.7 times compared to wild-type p53 binding with DNA (14 µM). Notably, the L265P mutation exhibited an approximately ten-fold greater reduction in binding affinity. Consequently, the presence of the L265P mutation in p53 could pose a substantial risk to humans. Given that p53 regulates abnormal tumor growth, this research carries significant implications for surveillance efforts and the development of anticancer therapies.

3.
Mol Ther Methods Clin Dev ; 32(3): 101288, 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39104576

RESUMO

Molecular cloning techniques enabling contemporaneous expression of two or more protein-coding sequences provide an invaluable tool for understanding the molecular regulation of cellular functions. The Cre-lox system is used for inducing the expression of recombinant proteins encoded within a bi-/poly-cistronic cassette. However, leak expression of transgenes is often observed in the absence of Cre recombinase activity, compromising the utility of this approach. To investigate the mechanism of leak expression, we generated Cre-inducible bi-cistronic vectors to monitor the expression of transgenes positioned either 5' or 3' of a 2A peptide or internal ribosomal entry site (IRES) sequence. Cells transfected with these bi-cistronic vectors exhibited Cre-independent leak expression specifically of transgenes positioned 3' of the 2A peptide or IRES sequence. Similarly, AAV-FLEX vectors encoding bi-cistronic cassettes or fusion proteins revealed the selective Cre-independent leak expression of transgenes positioned at the 3' end of the open reading frame. Our data demonstrate that 5' transgenes confer promoter-like activity that drives the expression of 3' transgenes. An additional lox-STOP-lox cassette between the 2A sequence and 3' transgene dramatically decreased Cre-independent transgene expression. Our findings highlight the need for appropriate experimental controls when using Cre-inducible bi-/poly-cistronic constructs and inform improved design of vectors for more tightly regulated inducible transgene expression.

4.
Microsc Res Tech ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38988203

RESUMO

The aim of this study was to compare of four different nickel-titanium (Ni-Ti) endodontic files and evaluate in terms of cyclic fatigue resistance and metallurgical properties. Four different type Ni-Ti root canal files Protaper Next X2 (PTN) (Dentsply Maillefer, Ballaigues, Switzerland), One Curve (OC) #25.06 (Micro Mega, Besancon, France), EndoPlus Flex Plus Gold X2 (EPG) (Turkuaz Dental, Denizli, Turkey), and EndoPlus Flex Plus Blue #25.06 (EPB) (Turkuaz Dental, Denizli, Turkey) files were tested for cyclic fatigue resistance (n = 20). During experiments artificial zirconia block canal was used. The artificial canal designed with curvature 60° and 5-mm radius. The number of cyclic to fracture (NCF) was noted. Fractured length (FL) parts of Ni-Ti files were recorded to assessment of fracture volumetric point. All fractured surfaces of Ni-Ti files were assessed by scanning electron microscope (SEM) to confirm the type of fractures. Descriptive evaluation become accomplished for the fundamental composition of units with the aid of using energy-dispersive x-ray spectroscopy (EDX). NCF data were evaluated via Bonferroni test with post hoc multiple comparison method. OC showed the highest NCF values (p < .05). The standardization of the study was confirmed as the FL of files was statistically similar in length (p > .05). SEM analysis confirmed that all scanned samples were fractured due to cyclic fatigue. EDX analysis confirmed that EPB established the poorest Ni content file. RESEARCH HIGHLIGHTS: The cyclic fatigue-related failure of One Curve was significantly more resistant than Protaper Next and EndoPlus files. Scanning electron microscopy images showed that One Curve and Protaper Next have round tips Energy dispersive x-ray spectroscopy showed that all four endodontic instruments mainly have Nickel and Titanium elements.

5.
Int Ophthalmol ; 44(1): 327, 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-38997613

RESUMO

PURPOSE: To report the long term visual outcomes and complications with use of the novel CM-T Flex scleral fixated intraocular lens (CMT-SFIOL). MATERIALS AND METHODS: 116 eyes that underwent CMT-SFIOL were reviewed and 57 eyes with CMT-SFIOL that completed a 2-year follow-up were included. Main outcome measures noted were best-corrected visual acuity (BCVA) and complications. Postoperatively, follow-ups were done at 1 week (1w), 1 month (1 m), 1 year (1y) and 2-year (2y) intervals. RESULTS: 40 (70.17%) of 57 eyes received CMT-SFIOL for surgical aphakia. Mean follow up was 39.77 ± 8.44 months. BCVA for distance & near improved from 1.26 ± 0.84 to 0.76 ± 0.77, 0.50 ± 0.72 and 0.51 ± 0.73 & 1.28 ± 0.58 to 0.98 ± 0.49, 0.92 ± 0.44 and 0.89 ± 0.40 at 1 m, 1y and 2y respectively (p < 0.001 for all). At 1w, 10 eyes (17.54%) had corneal edema (CE) and 8 eyes (14.03%) had anterior chamber (AC) reaction. Two eyes (3.50%) had IOP > 30 mm Hg and 1 eye (1.75%) had vitreous hemorrhage (VH). At 1 m, 3 eyes (5.26%) had CE and 5 eyes (8.77%) had AC reaction. Two eyes (3.50%) had IOP > 30 mm Hg and 1 eye (1.75%) had VH. Cystoid macular edema was noted in 3 eyes (5.26%). At 1y and 2y, 2 eyes (3.5%) and 1 eye (1.75%), had CE. No decentration, dislocation, haptic exposure or retinal detachment was noted. No eyes required resurgery. CONCLUSION: CM-T Flex SFIOL is an effective method to correct aphakia, with reliable and safe long-term results.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Desenho de Prótese , Esclera , Acuidade Visual , Humanos , Feminino , Masculino , Esclera/cirurgia , Lentes Intraoculares/efeitos adversos , Pessoa de Meia-Idade , Seguimentos , Estudos Retrospectivos , Idoso , Implante de Lente Intraocular/métodos , Implante de Lente Intraocular/efeitos adversos , Adulto , Complicações Pós-Operatórias/epidemiologia , Idoso de 80 Anos ou mais , Fatores de Tempo , Resultado do Tratamento , Afacia Pós-Catarata/cirurgia , Afacia Pós-Catarata/fisiopatologia
6.
J Appl Clin Med Phys ; 25(8): e14451, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38952057

RESUMO

PURPOSE: This study investigated the potential of a commercially available plastic scintillator, the Exradin W2, as a real-time dosimeter for ultra-high-dose-rate (UHDR) electron beams. This work aimed to characterize this system's performance under UHDR conditions and addressed limitations inherent to other conventional dosimetry systems. METHODS AND MATERIALS: We assessed the W2's performance as a UHDR electron dosimeter using a 16 MeV UHDR electron beam from the FLASH research extension (FLEX) system. Additionally, the vendor provided a beta firmware upgrade to better handle the processing of the high signal generated in the UHDR environment. We evaluated the W2 regarding dose-per-pulse, pulse repetition rate, charge versus distance, and pulse linearity. Absorbed dose measurements were compared against those from a plane-parallel ionization chamber, optically stimulated luminescent dosimeters and radiochromic film. RESULTS: We observed that the 1 × 1 mm W2 scintillator with the MAX SD was more suitable for UHDR dosimetry compared to the 1 × 3 mm W2 scintillator, capable of matching film measurements within 2% accuracy for dose-per-pulse up to 3.6 Gy/pulse. The W2 accurately ascertained the inverse square relationship regarding charge versus virtual source distance with R2 of ∼1.00 for all channels. Pulse linearity was accurately measured with the W2, demonstrating a proportional response to the delivered pulse number. There was no discernible impact on the measured charge of the W2 when switching between the available repetition rates of the FLEX system (18-180 pulses/s), solidifying consistent beam output across pulse frequencies. CONCLUSIONS: This study tested a commercial plastic scintillator detector in a UHDR electron beam, paving the way for its potential use as a real-time, patient-specific dosimetry tool for future FLASH radiotherapy treatments. Further research is warranted to test and improve the signal processing of the W2 dosimetry system to accurately measure in UHDR environments using exceedingly high dose-per-pulse and pulse numbers.


Assuntos
Elétrons , Plásticos , Contagem de Cintilação , Plásticos/química , Contagem de Cintilação/instrumentação , Contagem de Cintilação/métodos , Humanos , Radiometria/métodos , Radiometria/instrumentação , Dosagem Radioterapêutica , Imagens de Fantasmas , Aceleradores de Partículas/instrumentação
7.
J Med Phys ; 49(1): 84-94, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38828067

RESUMO

Purpose: The goal of this study is to investigate the dosimetric properties of a Semiflex three-dimensional (3D) chamber in an unflatten beam and compare its data from a small to a large field flattening filter-free (FFF) beam with different radiation detectors. Methods: The sensitivity, linearity, reproducibility, dose rate dependency, and energy dependence of a Semiflex 3D detector in flattening filter and filter-free beam were fully investigated. The minimum radiation observed field widths for all detectors were calculated using lateral electronic charged particle equilibrium to investigate dosimetric characteristics such as percentage depth doses (PDDs), profiles, and output factors (OPFs) for Semiflex 3D detector under 6FFF Beam. The Semiflex 3D measured data were compared to that of other detectors employed in this study. Results: The ion chamber has a dosage linearity deviation of +1.2% for <10 MU, a dose-rate dependency deviation of +0.5%, and significantly poorer sensitivity due to its small volume. There is a difference in field sizes between manufacturer specs and derived field sizes. The measured PDD, profiles, and OPFs of the Semiflex 3D chamber were within 1% of each other for all square field sizes set under linac for the 6FFF beam. Conclusion: It was discovered to be an appropriate detector for relative dose measurements for 6 FFF beams with higher dose rates for field sizes more than or equal to 3 cm × 3 cm.

8.
Sensors (Basel) ; 24(9)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38732882

RESUMO

Robotic exploration in dynamic and complex environments requires advanced adaptive mapping strategies to ensure accurate representation of the environments. This paper introduces an innovative grid flex-graph exploration (GFGE) algorithm designed for single-robot mapping. This hardware-scheme-based algorithm leverages a combination of quad-grid and graph structures to enhance the efficiency of both local and global mapping implemented on a field-programmable gate array (FPGA). This novel research work involved using sensor fusion to analyze a robot's behavior and flexibility in the presence of static and dynamic objects. A behavior-based grid construction algorithm was proposed for the construction of a quad-grid that represents the occupancy of frontier cells. The selection of the next exploration target in a graph-like structure was proposed using partial reconfiguration-based frontier-graph exploration approaches. The complete exploration method handles the data when updating the local map to optimize the redundant exploration of previously explored nodes. Together, the exploration handles the quadtree-like structure efficiently under dynamic and uncertain conditions with a parallel processing architecture. Integrating several algorithms into indoor robotics was a complex process, and a Xilinx-based partial reconfiguration approach was used to prevent computing difficulties when running many algorithms simultaneously. These algorithms were developed, simulated, and synthesized using the Verilog hardware description language on Zynq SoC. Experiments were carried out utilizing a robot based on a field-programmable gate array (FPGA), and the resource utilization and power consumption of the device were analyzed.

9.
Vasc Endovascular Surg ; 58(7): 752-756, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38747057

RESUMO

This case report documents the management of a 66-year old man with atrial fibrillation with recent placement of a WATCHMAN® Flex atrial appendage occlusion device. The patient presented with renal failure, abdominal pain, and difficulty walking 2 months after placement. The WATCHMAN® Flex device was found to have embolized to his abdominal aorta at the level of the renal arteries with associated thrombus. Extensive workup revealed reduced left ventricular cardiac function and decreased renal function, both of which were felt to be potentially reversible with device removal. The patient then underwent retrieval of the device and all associated thrombus via an open retroperitoneal approach. This case demonstrates a potential consequence of implanting devices such as an atrial appendage occlusion device and describes a technique for removal.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Remoção de Dispositivo , Migração de Corpo Estranho , Humanos , Idoso , Masculino , Apêndice Atrial/fisiopatologia , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Fibrilação Atrial/diagnóstico , Resultado do Tratamento , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/terapia , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Desenho de Prótese , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Trombose/etiologia , Trombose/diagnóstico por imagem , Trombose/terapia , Trombose/fisiopatologia , Aortografia , Angiografia por Tomografia Computadorizada , Embolia/etiologia , Embolia/diagnóstico por imagem , Embolia/terapia
10.
Int J Comput Assist Radiol Surg ; 19(8): 1555-1567, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38619791

RESUMO

PURPOSE: Heart valve disease is commonly treated by minimally invasive procedures with guide wires and catheterization. The main purpose of this study is to find out whether an extension of the guide wire with a sensor can support the surgeon within the blood vessel to reduce X-ray necessity. METHODS: A smart guide wire is developed by an extension with a flex-bending sensor to evaluate the sensor signal with and without "blood" flow at a constant compression force. Various surgically relevant investigations are performed. For assessment, the mean temporal average of the moving averaged filtered ADC signal and a subsequent FFT are carried out. RESULTS: Results show that there is a smaller sensor signal when the applied force or bending at the sensor is higher. In all investigations, there was a different sensor signal. The flex-bending sensor can detect the effect of pulsatile flow. The smallest temporal averaged signal difference between reference and clamp in the front wire's tip is 1.09%. For example, the mean temporal average of the filtered ADC signal for different clinically relevant scenarios is between 2550 and 2900. CONCLUSIONS: The results show that the sensorized guide wire developed for catheterization can support aortic valve implementation. The sensor sensitivity is sufficient to detect even very small variations within the blood vessel and therefore is promising to support catheterization heart valve surgeries in future.


Assuntos
Valva Aórtica , Cateterismo Cardíaco , Desenho de Equipamento , Imagens de Fantasmas , Humanos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentação
11.
Sensors (Basel) ; 24(7)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38610431

RESUMO

InGaAs detection systems have been increasingly used in the aerospace field, and due to the high signal-to-noise ratio requirements of short-wave infrared quantitative payloads, there is an urgent need for methods for the rapid and precise evaluation and the optimal design of these systems. The rigid-flex printed circuit board (PCB) is a vital component of InGaAs detectors, as its grid ground plane design parameters impact parasitic capacitance and thus affect weak infrared analog signals. To address the time-intensive and costly nature of design optimization achieved with simulations and experimental measurements, we propose an innovative method based on a neural network to predict the scattering parameters of rigid-flex boards for InGaAs detection links. This is the first study in which the effects of rigid-flex boards on weak infrared detection signals have been considered. We first obtained sufficient samples with software simulation. A backpropagation (BP) neural network prediction model was trained on existing sample sets and then verified on a rigid-flex board used in a crucial aerospace short-wave infrared quantitative mission. The model efficiently and accurately predicted high-speed interconnect scattering parameters under various rigid-flex board grid plane parameter conditions. The prediction error was less than 1% compared with a 3D field solver, indicating an overcoming of the iterative optimization inefficiency and showing improved design quality for InGaAs detection circuits.

12.
J Clin Med ; 13(8)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38673461

RESUMO

Background: Introduced in the latest BCLC 2022, endovascular trans-arterial radioembolization (TARE) has an important role in the treatment of unresectable hepatocellular carcinoma (HCC) as a "bridge" or "downstaging" of disease. The evolution of TARE technology allows a more flexible and personalized target treatment, based on the anatomy and vascular characteristics of each HCC. The flex-dose delivery program is part of this perspective, which allows us to adjust the dose and its radio-embolizing power in relation to the size and type of cancer and to split the therapeutic dose of Y90 in different injections (split-bolus). Methods: From January 2020 to January 2022, we enrolled 19 patients affected by unresectable HCC and candidates for TARE treatment. Thirteen patients completed the treatment following the flex-dose delivery program. Response to treatment was assessed using the mRECIST criteria with CT performed 6 and 9 months after treatment. Two patients did not complete the radiological follow-up and were not included in this retrospective study. The final cohort of this study counts eleven patients. Results: According to mRECIST criteria, six months of follow-up were reported: five cases of complete response (CR, 45.4% of cases), four cases of partial response (PR, 36.4%), and two cases of progression disease (PD, 18.2%). Nine months follow-up reported five cases of complete response (CR, 45.4%), two cases of partial response (PR, 18.2%), and four cases of progression disease (PD, 36.4%). No intra and post-operative complications were described. The average absorbed doses to the hepatic lesion and to the healthy liver tissue were 319 Gy (range 133-447 Gy) and 9.5 Gy (range 2-19 Gy), respectively. Conclusions: The flex-dose delivery program represents a therapeutic protocol capable of "saving" portions of healthy liver parenchyma by designing a "custom-made" treatment for the patient.

13.
Cureus ; 16(2): e53506, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38440012

RESUMO

INTRODUCTION: Biomechanical preparation has gotten easier over time with the development of nickel-titanium (NiTi) rotary instruments. Despite their benefits, research has shown that these files frequently result in microcracks in the root canal dentin, which can fracture the roots. Such mishaps should be prevented, as they compromise the integrity of the root and reduce the long-term survival of endodontically treated teeth. MATERIALS AND METHODS: This study was conducted at Government Dental College and Hospital, Patiala, Punjab, India. Eighty permanent mandibular premolar teeth were included. All the roots were inspected for any pre-existing cracks or craze lines under a stereomicroscope. The teeth were decoronated and then divided into four groups (n = 20): Group I: TruNatomy, Group II: Neoendo Flex, Group III: ProTaper Gold, and Group IV: 2Shape. The samples were instrumented according to the group to which they belonged. The roots were then sectioned horizontally at 3 mm and 6 mm from the apex and examined under a stereomicroscope at 40x for the presence of microcracks. RESULTS: The data were analyzed using the IBM SPSS Statistics for Windows, version 26 (released 2019; IBM Corp., Armonk, New York, United States). A chi-square test was applied, and the level of significance was set at p < 0.05. The highest incidence of microcracks was associated with ProTaper Gold (65%), followed by Neoendo Flex (45%), TruNatomy (20%), and 2Shape (20%). CONCLUSION:  All rotary instruments resulted in dentinal damage. ProTaper Gold exhibited the highest frequency of dentin cracks. TruNatomy and 2Shape exhibited satisfactory results with minimal crack formation.

14.
Top Companion Anim Med ; 59: 100862, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38508488

RESUMO

Two studies were developed to compare Borrelia burgdorferi antibody detection between the VetScan Flex4 and SNAP 4Dx Plus tests. The objective of the first study was to evaluate the diagnostic sensitivity (Se) and specificity (Sp) of VetScan Flex4 and SNAP 4Dx Plus B. burgdorferi results using field sourced samples compared to a Western Blot reference method. The sensitivity and specificity of VetScan Flex4 were 81.9 % (95 % CI: 71.9 %-89.5 %) and 89.3 % (95 % CI: 85.2 %-92.9 %) respectively, and SNAP 4Dx Plus's sensitivity and specificity were 80.7 % (95 % CI: 70.6 %-88.6 %) and 92.8 % (95 % CI: 89.1 %-95.5 %) respectively. When comparing VetScan Flex4 and Snap 4Dx Plus, the Simple Kappa Coefficient estimate was 0.76 (95 % CI: 0.69-0.84) indicating substantial agreement between the two methods. McNemar's Test revealed concordance between the two methods was not statistically significant (P = 0.05). The objective of the second study was to evaluate whether VetScan Flex4 differentiates between B. burgdorferi antibodies derived from infection versus vaccination with commonly used canine Lyme vaccines. The sensitivity and specificity of the VetScan Flex4 in differentiating canine Lyme vaccination from infection with Borrelia burgdorferi were 100 % (Se 95 % CI: 78.2 %-100 %; Sp 95 % CI: 91.2 %-100 %). In conclusion, the VetScan Flex4 is a reliably sensitive and specific point-of-care test that is similar to Snap 4Dx Plus, can differentiate between infection and Lyme vaccination, and can be utilized by veterinarians for Lyme disease diagnosis and surveillance of B. burgdorferi exposure.


Assuntos
Antígenos de Grupos Sanguíneos , Borrelia burgdorferi , Doenças do Cão , Doença de Lyme , Vacinas , Animais , Cães , Doenças do Cão/diagnóstico , Doença de Lyme/diagnóstico , Doença de Lyme/veterinária , Anticorpos Antibacterianos
15.
Diagnostics (Basel) ; 14(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38535077

RESUMO

The withdrawal of the iView detection system (iV) forced many cytopathology laboratories, including ours, to substitute immunocytochemical (ICC) staining protocols for routine practice with other detection systems. Our objective was to optimize, validate, and implement ICC protocols using OptiView (OV) and EnVision FLEX (EnV) detection systems, comparing the results with those obtained using iV. Residual cytologic samples with known diagnoses were used, testing antibodies for the ten most common markers in routine cytopathology diagnostics (calretinin, Ber-EP4, MOC-31, CKAE1/AE3, CK5/6, CD68, LCA, desmin, HBME-1, and WT1). Different staining parameters were tested using OV on BenchMark ULTRA and EnV on Dako Omnis immunostainer, respectively. Optimal staining protocols were then selected and validated on 10 positive and 10 negative cases. The staining results were compared with iV protocols through evaluation of UK NEQAS and internal scores. The optimal staining protocols with OV and EnV demonstrated similar or superior results compared to the existing iV protocols, with slightly stronger intensity regarding positive cells. We have successfully established and validated optimal ICC staining protocols for commonly used markers in routine cytopathology practice. These protocols may benefit other laboratories using similar staining platforms. However, the challenge regarding standardizing ICC protocols across different cytopathology laboratories remains unresolved.

16.
Urol Pract ; 11(3): 462-468, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38526412

RESUMO

INTRODUCTION: The Karl Storz FLEX-XC1 is a novel single-use flexible ureteroscope that uses the same videographics platform as its reusable digital counterpart. We evaluated the technical performance of the FLEX-XC1 in its initial clinical use. METHODS: We reviewed a series of consecutive ureteroscopy procedures performed by 2 endourologists using the FLEX-XC1 for indications for which we typically use a single-use device: total stone burden > 15 mm or > 10 mm in the lower pole, anticipated case duration > 60 minutes, bilateral procedure, or upper tract urothelial cancer procedures. We assessed device tip deflection, intraoperative mechanical failure, and clinical outcomes for each case. Surgeons rated visual clarity, image quality, and maneuverability on a 1 to 5 Likert scale. RESULTS: Of 29 procedures using FLEX-XC1, 27 (93%) were successfully completed. Preoperative upward deflection was < 270° in 6 (21%) cases, and downward deflection was < 270° in 9 (31%) cases. Three types of intraoperative malfunctions occurred: rotational twisting of deflectable tip (4 cases, 13%), device not advancing through distal ureter (1 case, 3%), and working channel not accommodating a 365-µm laser (1 case, 3%). Visual clarity, image quality, and maneuverability were rated as 5 "very good" or 4 "good" in 100%, 100%, and 97% of cases, respectively. No device-specific or general 30-day complications were observed. CONCLUSIONS: The FLEX-XC1 showed comparable image quality and maneuverability to reusable digital devices. We observed incomplete deflection in up to 31% of cases and mechanical failure in 2 cases. The FLEX-XC1 may be advantageous in prolonged cases where maintaining visual clarity is paramount.


Assuntos
Cálculos Renais , Ureteroscópios , Humanos , Desenho de Equipamento , Ureteroscopia , Cálculos Renais/cirurgia
17.
Cell Chem Biol ; 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38513646

RESUMO

Fluorescent tagging of biomolecules enables their sensitive detection during separation and determining their subcellular location. In this context, peroxidase-based reactions are actively utilized for signal amplification. To harness this potential, we developed a genetically encodable enzymatic fluorescence signal amplification method using APEX (FLEX). We synthesized a fluorescent probe, Jenfluor triazole (JFT1), which effectively amplifies and restricts fluorescence signals under fixed conditions, enabling fluorescence-based detection of subcellularly localized electron-rich metabolites. Moreover, JFT1 exhibited stable fluorescence signals even under osmium-treated and polymer-embedded conditions, which supported findings from correlative light and electron microscopy (CLEM) using APEX. Using various APEX-conjugated proteins of interest (POIs) targeted to different organelles, we successfully visualized their localization through FLEX imaging while effectively preserving organelle ultrastructures. FLEX provides insights into dynamic lysosome-mitochondria interactions upon exposure to chemical stressors. Overall, FLEX holds significant promise as a sensitive and versatile system for fluorescently detecting APEX2-POIs in multiscale biological samples.

18.
J Int Med Res ; 52(3): 3000605241233514, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38501996

RESUMO

OBJECTIVE: To compare the kinematic effects of two widely-used prefabricated ankle-foot orthoses (AFOs), the Dyna Ankle (DA) and UD Flex (UD), on the gait cycle of patients with hemiplegia due to cerebral palsy or acquired brain injury. METHODS: This was a retrospective cohort study involving 29 patients. Gait analysis results were assessed under three conditions: barefoot, with the DA, and with the UD. Friedman tests and post hoc analysis with Bonferroni correction were performed to assess differences between the three conditions. RESULTS: The DA significantly improved ankle dorsiflexion during the mid-swing phase, making it more effective in correcting foot drop compared with the UD (DA: 2.28°, UD: 0.44°). Conversely, the UD was more effective in preventing knee flexion during the loading response (DA: 28.11°, UD: 26.72°). CONCLUSIONS: The DA improved ankle dorsiflexion during the swing phase significantly more than that with the UD in patients with hemiplegia. Compared with the DA, the UD more effectively prevented increased knee flexion during the loading response. The choice to prescribe these orthoses should consider individual patient characteristics.


Assuntos
Tornozelo , Órtoses do Pé , Humanos , Hemiplegia , Estudos Retrospectivos , Articulação do Tornozelo
19.
Front Oncol ; 14: 1320280, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38420018

RESUMO

Introduction: Magnetic resonance imaging (MRI) staging scans are critical for the diagnosis and treatment of patients with nasopharyngeal cancer (NPC). We aimed to evaluate the application value of LAVA-Flex and T1WI-IDEAL sequences in MRI staging scans. Methods: Eighty-four newly diagnosed NPC patients underwent both LAVA-Flex and T1WI-IDEAL sequences during MRI examinations. Two radiologists independently scored the acquisitions of image quality, fat suppression quality, artifacts, vascular and nerve display. The obtained scores were compared using the Wilcoxon signed rank test. According to the signal intensity (SI) measurements, the uniformity of fat suppression, contrast between tumor lesions and subcutaneous fat tissue, and signal-to-noise ratio (SNR) were compared by the paired t-test. Results: Compared to the T1WI-IDEAL sequence, LAVA-Flex exhibited fewer artifacts (P<0.05), better visualization of nerves and vessels (P<0.05), and performed superior in the fat contrast ratio of the primary lesion and metastatic lymph nodes (0.80 vs. 0.52, 0.81 vs. 0.56, separately, P<0.001). There was no statistically significant difference in overall image quality, tumor signal-to-noise ratio (SNR), muscle SNR, and the detection rate of lesions between the two sequences (P>0.05). T1WI-IDEAL was superior to LAVA-Flex in the evaluation of fat suppression uniformity (P<0.05). Discussion: LAVA-Flex sequence provides satisfactory image quality and better visualization of nerves and vessels for NPC with shorter scanning times.

20.
BMC Immunol ; 25(1): 14, 2024 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336647

RESUMO

BACKGROUND: Haemoglobin (Hb) variants such as sickle cell trait (SCT/HbAS) play a role in protecting against clinical malaria, but little is known about the development of immune responses against malaria parasite (Plasmodium falciparum surface protein 230 (Pfs230) and Plasmodium falciparum erythrocyte binding antigen 175 region-3 (PfEBA175-3R)) and vector (on the An. gambiae Salivary Gland Protein-6 peptide 1 (gSG6-P1)) antigens in individuals with variants Hb genotypes. This study assessed antibody (IgG) responses against malaria parasite, Pfs230 and PfEBA175-3R and vector, gSG6-P1 in febrile individuals with variant Hb genotypes. METHODS: The study was conducted on symptomatic malaria patients attending various healthcare facilities throughout Ghana. Microscopy and ELISA were used to determine the natural IgG antibody levels of gSG6-P1, PfEBA175-3R & Pfs230, and Capillarys 2 Flex Piercing was used for Hb variants determination. RESULTS: Of the 600 symptomatic malaria patients, 50.0% of the participants had malaria parasites by microscopy. The majority 79.0% (398/504) of the participants had Hb AA, followed by HbAS variant at 11.3% (57/504) and HbAC 6.7% (34/504). There were significantly (p < 0.0001) reduced levels of gSG6-P1 IgG in individuals with both HbAC and HbAS genotypes compared to the HbAA genotype. The levels of gSG6-P1 IgG were significantly (p < 0.0001) higher in HbAS compared to HbAC. Similarly, Pfs230 IgG and PfEBA-175-3R IgG distributions observed across the haemoglobin variants were significantly higher in HbAC relative to HbAS. CONCLUSION: The study has shown that haemoglobin variants significantly influence the pattern of anti-gSG6-P1, Pfs230, and PfEBA-175 IgG levels in malaria-endemic population. The HbAS genotype is suggested to confer protection against malaria infection. Reduced exposure to infection ultimately reduces the induction of antibodies targeted against P. falciparum antigens.


Assuntos
Antígenos de Grupos Sanguíneos , Malária Falciparum , Malária , Humanos , Gana/epidemiologia , Hemoglobinas/metabolismo , Malária Falciparum/epidemiologia , Plasmodium falciparum , Genótipo , Imunoglobulina G , Imunidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA