Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 195
Filtrar
1.
J Vasc Surg ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39029810

RESUMO

INTRODUCTION: This study aimed to assess the impact of urgency on early and midterm outcomes of the Candy-Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair (TEVAR) for aortic dissection (AD). METHODS: The CP registry was reviewed, and patients were categorized into elective and urgent/emergent groups for analysis. Endpoints included technical success, clinical success, early (30-day) computed tomography angiography (CTA) findings, early (30-day) mortality, adverse events, aortic remodeling in patients with available CTA follow-up and re-intervention. RESULTS: A total of 155 patients received a custom-made Candy-Plug with 32 patients (44% males, mean age 61±9 years) were treated urgently vs. 123 patients (63% males, mean age 62±11 years) electively. The primary CP rate was higher in the urgent group; (28/32, (88%) in the urgent group vs. 96/123 (78%) in the elective group, p=051). The mean contrast volume was higher in the urgent group; (157±56ml in the urgent group vs. 130±71ml in the elective group, p=.017). Technical success was achieved in all patients in both groups. Clinical success was achieved in 25/32 (78%) patients in the urgent group vs. 113/123 (92%) in the elective group, p=.159. The early mortality rate was 4/32, (13%) patients in the urgent group vs. 1/123 (1%) in the elective group, p=.120). There was no statistically significant difference regarding the early adverse events between the urgent and elective CP groups. Early aortic-related re-interventions were required in 6/32 (19%) patients in the urgent group vs. 6/123 (5%) in the elective group, p=.094. Thoracic aortic aneurysm sac regression was lower in the urgent group (5/28, (18%) in the urgent group vs. 63/114 (55%) in the elective group, p=001). Stable thoracic aortic aneurysm sac was higher in the urgent group (22/28, (79%) in the urgent group vs. 47/114 (41%) in the elective group, p=000). An increase in thoracic aortic aneurysm sac occurred in 1/28 (4%) patient in the urgent group vs. 4/114 (4%) patients in the elective group, p=.096. CONCLUSION: The urgent use of the CP technique for distal FL occlusion in AD was feasible and effective. The decrease in aortic FL sac diameter may be affected by the urgent use of CP due to limited sizing availability. However, it achieved high rate of aortic remodeling.

2.
Healthcare (Basel) ; 12(13)2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38998798

RESUMO

Introduction: A residual false lumen after treatment for Aortic Dissection type A (AD) has been associated with early complications, such as A malperfusion or rupture and mid-term or delayed complications, such as aneurysm formation or dissection expansion. Thoracic Endovascular Aortic Repair (TEVAR) is considered an effective solution by several surgical teams to prevent future complications. In this systematic review, all published data regarding the implementation of TEVAR after previous treatment for AD were collected in order to investigate indications, methods, clinical outcomes and aortic remodeling in these patients. Methods: The aim of this study was to investigate the indications, the methods and the efficacy of TEVAR usage after surgical treatment of AD. Data for this study were collected from four widely used medical databases (MEDLINE, SCIENCE DIRECT, GOOGLE SCHOLAR, OVID). All the results for each database were recorded and were analyzed with a systematic method. Techniques and clinical outcomes were investigated. Aortic remodeling was evaluated based on the following parameters in these studies: aortic diameter, true lumen diameter, false lumen diameter, false lumen thrombosis and false lumen patency. Results: The results obtained from the search among all databases comprised 1410 articles and of these articles 9 were included in the review. The majority of the studies were retrospective (seven out of nine studies), while no study was randomized. The total number of patients was 157 and 133 of them (84.7% of patients) were treated with TEVAR in zone 3 without extension below the diaphragm intraoperatively. Among 142 patients, the calculated mortality rate was 12.7% (18 of 142 patients), with 2.8% (4 of 142 patients) presenting with stroke. The percentage of patients with total or partial thrombosis combined was 65.9% (62 patients in a population of 92). The reintervention rate was 18.7%. Conclusions: TEVAR after AD surgery is an approach usually chosen in clinical practice, but the criteria of its usage are uncertain. This method is safe and enhances aortic remodeling with an acceptable reintervention rate. Definite guidelines in this field should be created in order to delineate whether TEVAR after AD surgery is beneficial as a preventive measure to aorta-related complications and to decide under which criteria this approach should be chosen.

3.
Ann Vasc Surg ; 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39009131

RESUMO

OBJECTIVE: To investigate impact of Frozen Elephant Trunk (FET) on long-term distal aortic remodelling in acute AAD according to the latest recommended standards from the Society for Vascular Surgery (SVS)/Society of Thoracic Surgeons (STS). METHODS: Clinical data and imaging of patients undergone FET to treat acute AAD over the last 8 years were retrospectively reviewed. Patients were included if a pre- and post-operative Computed AngioTomographies at least 30-day from surgery was available for comparison. Contrasted postprocessed imaging were analysed with Aquarius iNtuition (TeraRecon Inc., Foster City, CA, USA) to analyse long-term positive aortic remodelling, FL thrombosis and aortic expansion according to the SVS/STS recommendations. Secondary endpoints were the rate of in-hospital and long-term mortality, spinal cord ischaemia and aortic-related reinterventions. RESULTS: Out of 75 patients who underwent FET for type A AAD, n=41(54.6%) were included. Significant positive aortic remodelling was reported in Ishimaru zone 1-4 but not in visceral/infrarenal aorta (p<0.001) and overall rate of FL thrombosis was 95.1% (n=39). Aortic expansion rates were: 4.9% in zones 1-4, 8.3% in zones 5-6 and 15% in zone 7. The rates of in-hospital mortality and long-term mortality were 7.3% (n=3) and 9.7% (n=4) respectively. At a median follow-up of 11 months (range 1-141, reintervention rate was 17.1%. CONCLUSIONS: We report positive aortic remodelling of the distal thoracic aorta in patients who underwent FET for acute AAD according to the SVS/STS reporting standards. The positive effect on the distal aorta is limited to the thoracic segments but not in the visceral aorta.

4.
J Vasc Surg Cases Innov Tech ; 10(5): 101553, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39069989

RESUMO

This case study presents an innovative endovascular approach using percutaneous gluteal artery access for embolizing the false lumen of a type B aortic dissection in a patient with Marfan syndrome. Following multiple complex surgeries, the patient developed an enlarging thoraco-abdominal aneurysm, necessitating an urgent intervention branched endoprosthesis despite persisting false lumen perfusion. Doppler ultrasound-guided percutaneous gluteal access was utilized for spiral-coil embolization of the false lumen. Successful embolization and exclusion of the aneurism, confirmed by follow-up angiography and computed tomography scans, demonstrated the technique's efficacy and safety. This approach underscores the need for innovative solutions addressing complex vascular pathologies in patients with Marfan.

5.
Expert Rev Med Devices ; : 1-4, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38803133

RESUMO

INTRODUCTION: The management of the false lumen (FL) when dealing with aortic dissection is a crucial aspect since inducing its thrombosis is necessary in order to achieve aortic remodeling. One of the pitfalls of endovascular treatment of aortic dissection (AD) is retrograde distal FL perfusion and pressurization, which prevents FL thrombosis and thus aortic remodeling, while being associated with aneurysmal degeneration of the FL and poor long-term outcomes. AREAS COVERED: Currently, there is no CE/FDA approved device for FL closure, however different techniques and devices have been proposed to overcome this challenge, the most known of which is the Candy Plug (CP). This review aims to describe the CP device, its implantation technique, and the available data in the literature (PubMed, Cochrane, and EMBASE databases; last queried, December 31, 2023). EXPERT OPINIONS: While the treatment of AD remains technically challenging, the use of the CP technique to close any distal FL reperfusion proved to be feasible and safe with excellent rates of both technical and clinical success. Furthermore, recent studies have shown a quick learning curve with this technique.

6.
Am J Cardiol ; 221: 77-83, 2024 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-38636625

RESUMO

The impact of inconsistent enhancement within the patent false lumen on the occurrence of late aortic events remains uncertain. We enrolled 55patients who exhibited a patent false lumen after hemiarch replacement. The Hounsfield unit (HU) measurements in the patent false lumen were obtained at 2 specific locations: the aortic arch (a) and the descending aorta (b). The false lumen HU score was calculated as the absolute value of 1 - a/b, representing the discrepancy in HUs within the patent false lumen. We investigated the cut-off value of the false lumen HU score with the receiver operating characteristics curve to predict the incidence of late aortic events. We divided the patients based on the cut-off value and compared the cumulative incidence of the late aortic events. The analysis of the receiver operating characteristics curve showed that the cut-off value of the false lumen HU score was 0.345. Based on this cut-off value, we divided them into 2 groups: Group A (score <0.345, n = 26) and Group B (score ≥0.345, n = 29). The baseline characteristics were similar between the 2 groups. The cumulative incidence of the late aortic events was significantly lower in Group A (7.8% at 5 years) than in Group B (39.9% at 5 years) (p = 0.02). The false lumen HU score might be useful to predict the incidence of late aortic events after hemiarch replacement.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Complicações Pós-Operatórias , Humanos , Dissecção Aórtica/cirurgia , Feminino , Masculino , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Complicações Pós-Operatórias/epidemiologia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Angiografia por Tomografia Computadorizada/métodos , Curva ROC , Incidência , Doença Aguda
7.
J Endovasc Ther ; : 15266028241246656, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659327

RESUMO

PURPOSE: The purpose was to describe a technique to promote false lumen (FL) thrombosis in post-dissection thoracoabdominal aortic aneurysms (PD-TAAAs) managed by fenestrated/branched endografting (F/B-EVAR). TECHNIQUE: A 5/6Fr-90 cm length sheath is advanced from the true lumen (TL) to FL through the most distal entry tear of the infrarenal aorta or iliac arteries. It is parked in the most cranial portion of the FL in the thoracic aorta. Aortic endografts are deployed in the TL excluding all the para-visceral/distal entry tears and target visceral vessels bridging stenting is performed. A selective FL angiography is performed through the 5/6Fr sheath to detect the origin of all segmentary arteries. Embolization of FL is performed from above to below by M-reye pushable coils, obtaining the packaging of FL. After completion angiography, the 5/6Fr sheath is retrieved in external iliac artery and molding ballooning of the distal segment of the aortic/iliac endograft is performed. Between 2019 and 2023, this technique was applied in 11cases with a median number of 73 (interquartile range [IQR=12) coils. Out of 8 (72%) patients with available radiological follow-up at 1 year, 7 exhibited complete FL thrombosis. CONCLUSIONS: The FL coiling in PD-TAAAs managed by F/B-EVAR is feasible, safe, and effective to promote the complete FL thrombosis. CLINICAL IMPACT: Preemptive false lumen embolization is a feasible, safe, and effective technique for preventing persistent type II endoleaks after fenestrated-branched endovascular repair of post-dissection thoracoabdominal aortic aneurysms. This technique may be routinely recommended to promote FL thrombosis and aortic remodeling after FB-EVAR in PD-TAAAs, thereby reducing the incidence of reinterventions during follow-up.

8.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38676575

RESUMO

OBJECTIVES: Conventional treatment for type A aortic dissection includes replacement of the ascending aorta with an open distal anastomosis in the hemiarch position. The frozen elephant trunk (FET) is a hybrid technique that extends the repair to the descending thoracic aorta. The goal is to improve resolution of malperfusion syndrome and to induce positive aortic remodelling and reduce the need for reintervention on the downstream aorta. We aim to summarize the data on the short and long-term outcomes of this technique. METHODS: A thorough search of the literature was conducted isolating all articles dealing with aortic remodelling after the use of FET in case of type A acute aortic dissection. Keywords 'aortic dissection', 'frozen elephant trunk', 'aortic remodelling' and 'false lumen thrombosis' were used. Data for type B and chronic aortic dissections were excluded. RESULTS: FET use favourably influences aortic remodelling. The main advantages lie in the exclusion of distal entry tears in either the aortic arch or descending aorta thus restoring antegrade blood flow in the true lumen and inducing false lumen thrombosis. False lumen thrombosis is not only induced at the level of the stent deployment but also lower in the distal descending aorta. Moreover, it offers an adequate landing zone in the mid-descending aorta for second-stage endovascular or open surgical aortic repair, if needed. CONCLUSIONS: FET can be advantageous in the treatment of acute type A aortic dissection dealing with extended aortic pathology.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Humanos , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Aneurisma da Aorta Torácica/cirurgia , Doença Aguda , Prótese Vascular , Aorta Torácica/cirurgia , Procedimentos Endovasculares/métodos , Stents , Resultado do Tratamento
9.
Echocardiography ; 41(4): e15810, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38555578

RESUMO

The aortic short axis view demonstrated the widening of the pulmonary artery and the membrane-like echo in the pulmonary artery divided it into true lumen and false lumen. And the flow of the ruptured openings on the band-like echo was clearly revealed by Color Doppler.


Assuntos
Dissecção Aórtica , Comunicação Interventricular , Estenose da Valva Pulmonar , Humanos , Ecocardiografia , Artéria Pulmonar/diagnóstico por imagem , Comunicação Interventricular/complicações , Comunicação Interventricular/diagnóstico por imagem , Estenose da Valva Pulmonar/complicações , Estenose da Valva Pulmonar/diagnóstico por imagem
11.
Vasc Endovascular Surg ; 58(5): 505-511, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38258617

RESUMO

INTRODUCTION: We sought to examine midterm results and remodeling effect of false-lumen occlusion treatment using AFX VELA in case of chronic dissection repair. MATERIAL AND METHODS: From June 2019 to May 2022, we performed false lumen occlusion treatment using a modified Candy-Plug technique with AFX VELA on 8 chronic aortic dissection patients with a patent false lumen. We collected operative data, short-term clinical outcomes, mid-term clinical outcomes and imaging test results. We conducted follow-up examinations at postoperative, 6-month and 1-, 2- and 3-year intervals, including contrast-enhanced computed tomography to evaluate the diameter, false lumen thrombosis and any events. RESULTS: The average time from the symptom onset to the thoracic endovascular repair was 81.5 (35-155) months. The aorta showed aneurysmal dilation with an average maximum short-axis diameter of 58.9 (41-91) mm. Two cases needed emergency surgery due to rupture and impending rupture. There were no postoperative deaths. Complete thrombosis within the false lumen was achieved in 6 cases (75%), but 2 cases had incomplete thrombosis, requiring additional treatment. The mean maximum diameter showed a significant decrease at 6 months, 1 year and 2 years postoperatively compared to preoperative measurements (P < .05). CONCLUSION: We showed the results of false lumen occlusion treatment using the AFX VELA cuff. We observed favorable clinical outcomes and remodeling effects. While the long-term durability and efficacy of this technique in aortic remodeling will need to be monitored with further observation, the use of this cuff is considered a reliable approach to false lumen occlusion treatment.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Humanos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Dissecção Aórtica/fisiopatologia , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Doença Crônica , Idoso , Feminino , Fatores de Tempo , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/fisiopatologia , Desenho de Prótese , Stents , Remodelação Vascular
12.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37988138

RESUMO

OBJECTIVES: This study aimed to investigate the relationship between false lumen morphology and the size, aortic segment and position of the entry tear for acute type A aortic dissection. METHODS: The records of patients who underwent emergency operation for acute type A aortic dissection in our institution between April 2011 and May 2022 were examined. Data regarding size, location and position of the entry tear and preoperative computed tomography findings were reviewed. The relationship of these variables with false lumen morphology was examined and retrospectively compared according to tear size. RESULTS: Of 243 cases, characteristics of the entry tear, visualized during surgery, were confirmed in 134 cases (age = 70.9 ± 12.6 years, male = 45.5%). Tear sizes at different aortic segments were not significantly different (P = 0.376). Tears posterior to the lesser curvature were significantly smaller than those anterior to the greater curvature (P = 0.004). A thrombosed false lumen was associated with a significantly smaller tear size and position on the posterior to the lesser curvature side in aortic cross-section (all P < 0.001). Multivariate analysis showed that tear size, the presence of re-entry and tear position anterior to the greater curvature were independent predictors of a patent false lumen. CONCLUSIONS: In acute type A aortic dissection, larger tear size, the presence of re-entry and tear position anterior to the greater curvature are risk factors for a patent false lumen. Although the results of this study are valid only for patients in whom intimal tears were detected during aortic surgery, this trend may provide information for pathophysiology of the disease.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma Aórtico , Dissecção Aórtica , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Estudos Retrospectivos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta , Fatores de Risco , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia
13.
Artigo em Inglês | MEDLINE | ID: mdl-37948001

RESUMO

OBJECTIVE: We evaluated the blood flow within the downstream aortic false lumen after frozen elephant trunk repair for acute aortic dissection and identified hemodynamic predictors of false lumen expansion and negative false lumen remodeling using four-dimensional flow magnetic resonance imaging. METHODS: Thirty-one patients (Stanford type A, n = 28; Stanford type B, n = 3) with patent false lumen who underwent frozen elephant trunk procedures for acute aortic dissection were included in this observational study. Each patient underwent computed tomography during the follow-up period and four-dimensional flow magnetic resonance imaging within 3 postoperative months. The false lumen volumetric expansion rate was calculated using computed tomography data. The direction and the rate of flow in the lower descending aortic false lumen were analyzed. Negative false lumen remodeling was defined as a volumetric increase of > 10% from the baseline volume. RESULTS: Negative false lumen remodeling had developed in 6 of the 31 patients during the observation period. Most of the false lumen flows were biphasic during systole. The range between peak and nadir flow rates was associated with the false lumen volumetric expansion rate (ß coefficient = 6.77; p < 0.01, R2 = 0.43). CONCLUSIONS: The range between peak and nadir flow rates may serve as a hemodynamic predictor of negative false lumen remodeling, enabling further treatment for patients at risk of expansion in the downstream aorta.

14.
CVIR Endovasc ; 6(1): 58, 2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38019332

RESUMO

BACKGROUND: Although the candy-plug technique has been reported to be useful for the treatment of post-dissection aortic aneurysm, the stent graft needs be to customized to accommodate the size of vascular occluders. CASE PRESENTATION: We present a case of a persistent false lumen successfully treated with endovascular stent-graft and atrial septal defect occluder in a patient with Stanford Type B dissection. A covered stent graft was implanted into the false cavity through a distal rupture, and an atrial septal defect occluder was inserted into the covered stent to seal of the false cavity. Decreased aneurysmal diameter and false lumen thrombosis were noted by CT scan at 6-month follow-up. CONCLUSIONS: Our case showed that combined use of a stent graft and atrial septal defect occluder is safe, technically feasible and effective in sealing of the false lumen in post-dissection aortic aneurysm patients with previously failed false lumen thrombosis.

15.
JTCVS Open ; 15: 16-24, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37808063

RESUMO

Objective: To investigate the association between false lumen (FL) dependency of segmental arteries (SAs) at T9-L3 levels and the risk of spinal cord injury (SCI) following total arch replacement and frozen elephant trunk (FET) implantation in the setting of acute DeBakey type I aortic dissection (AAD). Methods: The study involved consecutive patients with AAD who underwent total arch replacement and FET implantation between 2020 and 2022. Primary outcome was postoperative SCI. The inverse probability of treatment weighting (IPTW) method was employed to minimize the impact of no-randomization bias. Antegrade placement of FET was followed by end-to-end anastomosis of a 4-branch arch graft at the proximal landing site of FET. Results: A total of 146 patients were included (age, 50.5 ± 11.7 years, 115 male), of whom 35 (24%) had SAs at T9-L3 levels completely dependent on FL (FL-dependency group). There was no significant difference in early (30-day or in-hospital) mortality rates between FL-dependency (14.3%) and FL-independency (18.0%) groups (P = .80), however, the rate of SCI was significantly higher in the FL-Dependency group (34.3% vs 2.7%, P < .001). After adjustments, FL dependency was associated with a significantly increased risk of SCI (odds ratio, 13.1; 95% confidence interval, 4.2-41.0; P < .001), whereas it was not significantly associated with risks of early mortality or other major complications (P = .16-.98). Conclusions: FL dependency of SAs at the T9-L3 levels was significantly associated with the development of SCI following FET implantation in AAD, warning against its uses on patients presenting with FL dependency of SAs at critical segments.

16.
Postgrad Med J ; 99(1178): 1226-1236, 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37773985

RESUMO

The prevalence of spontaneous coronary artery dissection (SCAD) has increased over the last decades in young adults presenting with acute coronary syndrome. Although the diagnostic tools, including intracoronary imaging, have permitted a more accurate diagnosis of SCAD, the prognosis and overall outcomes remain dismal. Furthermore, the disproportionate sex distribution affecting more women and the underdiagnosis in many parts of the world render this pathology a persistent clinical challenge, particularly since the management remains largely supportive with a limited and controversial role for percutaneous or surgical interventions. The purpose of this review is to summarize the available literature on SCAD and to provide insights into the gaps in knowledge and areas requiring further investigation.


Assuntos
Anomalias dos Vasos Coronários , Doenças Vasculares , Adulto Jovem , Humanos , Feminino , Vasos Coronários , Angiografia Coronária , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/terapia , Prognóstico , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/epidemiologia
17.
J Thorac Dis ; 15(8): 4306-4313, 2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37691648

RESUMO

Background: Although current research revealed the preoperative diameter of the aorta is related to aortic remodeling, prognosis should consider the true lumen (TL) and false lumen (FL) respectively too. Methods: The cohort of this retrospective analysis included 161 type A aortic dissection (TAAD) patients who underwent surgery at a single institution from September 1, 2017, to September 1, 2018. Computed tomography angiography (CTA) images were reviewed to assess changes of the diameters of the TL, FL and total aorta at the levels of the stented segment, distal end of the stent, celiac trunk, and below the renal artery. Results: During the study period, positive remodeling was observed in 33 (20.5%) patients. The probability of negative remodeling far from the stent segment was greater than the aorta close to the stent. Only the TL diameter was associated with each levels' changes and underwent significant change (P<0.05). Multivariate analysis identified aortic regurgitation as a risk factor for remodeling in the distal end of the stent. The maximum diameter of the FL was the only risk factor related to the remodeling type (odds ratio =0.10; 95% confidence interval: 0.01-0.51), a maximum diameter of the FL of >1.28 cm was associated with a higher probability of negative remodeling after surgery (specificity =0.994; sensitivity =0.571; area under the receiver operating characteristic curve =0.76). Conclusions: The TL and FL diameters on preoperative CTA images can be used to assess the risk of negative remodeling after surgery.

18.
J Clin Med ; 12(14)2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37510886

RESUMO

Objective: Advanced endovascular options for acute and chronic pathology of the ascending aorta are emerging; however, several problems with stent grafts placed in the ascending aorta have been identified in patients unsuitable for surgical repair, such as migration and erosion at aorta interface. Method: Among the six cases analysed in this report, three were treated with a stent graft in the ascending aorta to manage chronic dissection in the proximal aorta; dimensions of those stent grafts varied between 34 and 45 mm in diameter, and from 77 to 100 mm in length. Three patients, matched by age, sex and their nature of pathology, were subjected to the focal closure of a single communicating entry by the use of an occluding device (Amplatzer ASD and PFO occluders between 14 and 18 mm disc diameter) with similar Charlson comorbidity score. Results: Both conceptually different nonsurgical management strategies were technically feasible; however, with stent grafts, an early or delayed erosion to full re-dissection was documented with stent grafts, in contrast to complete seal, with an induced remodelling and a long-term survival after the successful placing of coils and occluder devices. Moreover, aortic root motion was not impaired by the focal occlusion of a communication with an occluder, while free motion was impeded after stent graft placement. Conclusions: The intriguing observation in our small series was that stent grafts placed in the ascending aorta portends the risk of an either early (post-procedural) or delayed migration and erosion of aortic tissues at the landing site or biological interface between 12 and 16 months after the procedure, a phenomenon not seen with the use of focal occluding devices up to 5 years of follow-up. Obviously, the focal approach avoids the erosion of the aortic wall as the result of minimal interaction with the biological interface, such as a diseased aortic wall. Potential explanations may be related to a reduced motion of the aortic root after the placement of stent graft in the ascending aorta, whereas the free motion of aortic root was preserved with an occluder. The causality of erosion may however not be fully understood, as besides the stiffness and radial force of the stent graft, other factors such as the induced inflammatory reactions of aortic tissue and local adhesions within the chest may also play a role. With stent grafts failing to portend long-term success, they may still have a role as a temporizing solution for elective surgical conversion. Larger datasets from registries are needed to further explore this evolving field of interventions to the ascending aorta.

19.
J Vasc Surg ; 78(5): 1146-1152, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37406944

RESUMO

OBJECTIVE: Management of postdissection thoracoabdominal aneurysms with a fenestrated and/or branched endograft (F/BEVAR) is associated with favorable outcomes. Treatment should include both true lumen endografting and false lumen occlusion (FLO). Favorable results have recently been reported for FLO in the false lumen of the thoracic aorta. The purpose of this study is to analyze the results of FLO of the abdominal aorta in patients treated for post dissection thoracoabdominal aneurysm. METHODS: A multicenter retrospective analysis of prospective data of consecutive patients managed for post dissection thoracoabdominal aortic aneurysm from April 2019 to December 2022 with F/BEVAR associated with FLO in the abdominal false lumen was conducted. The STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) was followed. Baseline demographics, operative details, and early outcomes (mortality, length of stay) were recorded. Primary endpoints were technical and clinical success. FLO technical success was defined as complete occlusion of false lumen backflow above the FLO on completion angiogram. RESULTS: During the 3-year study, 23 patients were treated for post dissection thoracoabdominal aneurysm with F/BEVAR and the use of abdominal FLO. Twenty-one patients (91.3%) had received prior endovascular treatment. The technical and clinical success was 95.7%. The abdominal FLO had a technical success rate of 78.3%. The median diameter of the FLO was 34 mm. No patient died during the perioperative period, and one patient had spinal cord ischemia (4.3%) with partial recovery. Six patients (26.1%) required early reintervention. The median duration of hospitalization in the intensive care unit and overall was 1 day (interquartile range, 0-3 days) and 7.5 days (interquartile range, 2-22 days), respectively. During the mean follow-up of 9.9 ± 9.0 months, no patient died. False lumen occlusion was complete or partial in nine (39.1%) and nine (39.1%) patients, respectively. No aortic rupture occurred during follow-up. Maximum aortic diameter decreased in 48% and remained stable in 39% of cases. CONCLUSIONS: Abdominal aorta FLO during endovascular treatment of post dissection thoracic abdominal aortic aneurysm is associated with favorable outcomes. It offers an additional staging therapeutic option before extensive aorto-bi-iliac coverage, associated with low spinal cord ischemia rates. FLO also provides high rates of false lumen occlusion and false lumen remodeling during follow-up. Longer follow-up and larger cohorts are required to confirm these very promising early findings.

20.
Ann Card Anaesth ; 26(3): 333-335, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37470535

RESUMO

In communicating aortic dissection, if only the entry or reentry is closed, residual blood flow may cause enlargement of the false lumen. In this case, surgeons were unable to occlude the entry with a stent graft due to the strong flexion of the bilateral common iliac arteries, so they closed only the reentry in the hope that blood flow from the reentry would be high. Unfortunately, due to the high blood flow from the entry, the false lumen was enlarged. But the use of transesophageal echocardiography and epiaortic ultrasound contributed to its diagnosis.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Ecocardiografia Transesofagiana , Aneurisma da Aorta Torácica/cirurgia , Stents , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA