Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 31(Pt 5): 1118-1125, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39105530

RESUMO

The normalization of X-ray absorption near-edge structure (XANES) spectra is required for comparing spectral features and extracting quantitative information in analytical techniques such as linear combination analysis, principal component analysis and multivariate curve resolution. Most published data are normalized to the edge-jump, but normalization to the spectral area has also been applied. The latter is particularly attractive if only a small energy range around the absorption can be recorded reliably. Here, the two normalization methods are compared at the L3-edge of Pt, Pd and Rh, and at the Ni K-edge using experimental and calculated spectra. Normalization to the spectral area is found to be a viable approach if the range for the area normalization is sufficiently large.

2.
J Synchrotron Radiat ; 31(Pt 4): 733-740, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38920268

RESUMO

L3-edge high-energy-resolution fluorescence-detection X-ray absorption near-edge structure (XANES) spectra for palladium and rhodium compounds are presented, with focus on their electronic structures. The data are compared with transmission XANES spectra recorded at the K-edge. A correlation between the absorption edge energy and the metal ion oxidation state is not observed. Despite the different filling of the 4d orbitals and different local coordination, the Rh and Pd compounds show remarkably similar spectral shapes. Calculation of the density of states and of the L3-XANES data reproduce the experimental results.

3.
J Synchrotron Radiat ; 30(Pt 6): 1183, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37850564

RESUMO

The name of an author in the article by Saurette et al. (2022) [J. Synchrotron Rad. 29, 1198-1208] is corrected.

4.
Chemphyschem ; 24(23): e202300113, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37768846

RESUMO

A new approach for the characterization of CO2 methanation catalysts prepared by thermal decomposition of a nickel MOF by hard X-ray photon-in/photon-out spectroscopy in form of high energy resolution fluorescence detected X-ray absorption near edge structure spectroscopy (HERFD-XANES) and valence-to-core X-ray emission (VtC-XES) is presented. In contrast to conventional X-ray absorption spectroscopy, the increased resolution of both methods allows a more precise phase determination of the final catalyst, which is influenced by the conditions during MOF decomposition.

5.
J Synchrotron Radiat ; 29(Pt 5): 1198-1208, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36073878

RESUMO

High-energy-resolution fluorescence-detected (HERFD) X-ray absorption near-edge spectroscopy (XANES) is a spectroscopic method that allows for increased spectral feature resolution, and greater selectivity to decrease complex matrix effects compared with conventional XANES. XANES is an ideal tool for speciation of elements in solid-phase environmental samples. Accurate speciation of As in mine waste materials is important for understanding the mobility and toxicity of As in near-surface environments. In this study, linear combination fitting (LCF) was performed on synthetic spectra generated from mixtures of eight measured reference compounds for both HERFD-XANES and transmission-detected XANES to evaluate the improvement in quantitative speciation with HERFD-XANES spectra. The reference compounds arsenolite (As2O3), orpiment (As2S3), getchellite (AsSbS3), arsenopyrite (FeAsS), kankite (FeAsO4·3.5H2O), scorodite (FeAsO4·2H2O), sodium arsenate (Na3AsO4), and realgar (As4S4) were selected for their importance in mine waste systems. Statistical methods of principal component analysis and target transformation were employed to determine whether HERFD improves identification of the components in a dataset of mixtures of reference compounds. LCF was performed on HERFD- and total fluorescence yield (TFY)-XANES spectra collected from mine waste samples. Arsenopyrite, arsenolite, orpiment, and sodium arsenate were more accurately identified in the synthetic HERFD-XANES spectra compared with the transmission-XANES spectra. In mine waste samples containing arsenopyrite and either scorodite or kankite, LCF with HERFD-XANES measurements resulted in fits with smaller R-factors than concurrently collected TFY measurements. The improved accuracy of HERFD-XANES analysis may provide enhanced delineation of As phases controlling biogeochemical reactions in mine wastes, contaminated soils, and remediation systems.


Assuntos
Poluentes do Solo , Trióxido de Arsênio , Mineração , Espectroscopia por Absorção de Raios X/métodos
6.
Chemistry ; 28(21): e202200119, 2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35179271

RESUMO

Reaction of the N-heterocylic carbene ligand i PrIm (L1 ) and lithium bis(trimethylsilyl)amide (TMSA) as a base with UCl4 resulted in U(IV) and U(V) complexes. Uranium's +V oxidation state in (HL1 )2 [U(V)(TMSI)Cl5 ] (TMSI=trimethylsilylimido) (2) was confirmed by HERFD-XANES measurements. Solid state characterization by SC-XRD and geometry optimisation of [U(IV)(L1 )2 (TMSA)Cl3 ] (1) indicated a silylamido ligand mediated inverse trans influence (ITI). The ITI was examined regarding different metal oxidation states and was compared to transition metal analogues by theoretical calculations.

7.
J Synchrotron Radiat ; 29(Pt 1): 21-29, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34985419

RESUMO

The uranium valence electronic structure in the prototypical undistorted perovskite KUO3 is reported on the basis of a comprehensive experimental study using multi-edge HERFD-XAS and relativistic quantum chemistry calculations based on density functional theory. Very good agreement is obtained between theory and experiments, including the confirmation of previously reported Laporte forbidden f-f transitions and X-ray photoelectron spectroscopic measurements. Many spectral features are clearly identified in the probed U-f, U-p and U-d states and the contribution of the O-p states in those features could be assessed. The octahedral crystal field strength, 10Dq, was found to be 6.6 (1.5) eV and 6.9 (4) eV from experiment and calculations, respectively. Calculated electron binding energies down to U-4f states are also reported.

8.
J Phys Condens Matter ; 33(28)2021 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-33957610

RESUMO

A scanning multi-crystal x-ray emission spectrometer to perform photon-in/photon-out spectroscopy at the I20-Scanning beamline at Diamond Light Source is described. The instrument, equipped with three analyzer crystals, is based on a 1 m Rowland circle spectrometer operating in the vertical plane. The energy resolution of the spectrometer is of the order of 1 eV, having sufficient resolving power to overcome the core-hole lifetime broadening of most of the transition metalsK-edges. Examples showing the capability of the beamline for performing high energy resolution fluorescence detection x-ray absorption spectroscopy (HERFD-XAS), non-resonant x-ray emission spectroscopy (XES) and resonant x-ray emission spectroscopy are presented. The comparison of the Zn and MnK-edge HERFD-XANES of ZnO and MnO withab initiocalculations shows that the technique provides enhanced validation of the models by making subtle spectral features more visible.

9.
Environ Sci Technol ; 55(8): 4753-4761, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33705103

RESUMO

Metal-reducing microorganisms such as Shewanella oneidensis MR-1 reduce highly soluble species of hexavalent uranyl (U(VI)) to less mobile tetravalent uranium (U(IV)) compounds. The biologically mediated immobilization of U(VI) is being considered for the remediation of U contamination. However, the mechanistic underpinnings of biological U(VI) reduction remain unresolved. It has become clear that a first electron transfer occurs to form pentavalent (U(V)) intermediates, but it has not been definitively established whether a second one-electron transfer can occur or if disproportionation of U(V) is required. Here, we utilize the unusual properties of dpaea2- ((dpaeaH2═bis(pyridyl-6-methyl-2-carboxylate)-ethylamine)), a ligand forming a stable soluble aqueous complex with U(V), and investigate the reduction of U(VI)-dpaea and U(V)-dpaea by S. oneidensis MR-1. We establish U speciation through time by separating U(VI) from U(IV) by ion exchange chromatography and characterize the reaction end-products using U M4-edge high resolution X-ray absorption near-edge structure (HR-XANES) spectroscopy. We document the reduction of solid phase U(VI)-dpaea to aqueous U(V)-dpaea but, most importantly, demonstrate that of U(V)-dpaea to U(IV). This work establishes the potential for biological reduction of U(V) bound to a stabilizing ligand. Thus, further work is warranted to investigate the possible persistence of U(V)-organic complexes followed by their bioreduction in environmental systems.


Assuntos
Shewanella , Urânio , Biodegradação Ambiental , Ligantes , Oxirredução
10.
J Synchrotron Radiat ; 28(Pt 1): 333-349, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399586

RESUMO

ROBL-II provides four different experimental stations to investigate actinide and other alpha- and beta-emitting radionuclides at the new EBS storage ring of ESRF within an energy range of 3 to 35 keV. The XAFS station consists of a highly automatized, high sample throughput installation in a glovebox, to measure EXAFS and conventional XANES of samples routinely at temperatures down to 10 K, and with a detection limit in the sub-p.p.m. range. The XES station with its five bent-crystal analyzer, Johann-type setup with Rowland circles of 1.0 and 0.5 m radii provides high-energy resolution fluorescence detection (HERFD) for XANES, XES, and RIXS measurements, covering both actinide L and M edges together with other elements accessible in the 3 to 20 keV energy range. The six-circle heavy duty goniometer of XRD-1 is equipped for both high-resolution powder diffraction as well as surface-sensitive CTR and RAXR techniques. Single crystal diffraction, powder diffraction with high temporal resolution, as well as X-ray tomography experiments can be performed at a Pilatus 2M detector stage (XRD-2). Elaborate radioprotection features enable a safe and easy exchange of samples between the four different stations to allow the combination of several methods for an unprecedented level of information on radioactive samples for both fundamental and applied actinide and environmental research.

11.
Front Microbiol ; 11: 584715, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33154741

RESUMO

Microorganisms are key players in the transformation of mercury into neurotoxic methylmercury (MeHg). Nevertheless, this mechanism and the opposite MeHg demethylation remain poorly understood. Here, we explored the impact of inorganic mercury (IHg) and MeHg concentrations from 0.05 to 50 µM on the production and degradation of MeHg in two sulfate-reducing bacteria, Pseudodesulfovibrio hydrargyri BerOc1 able to methylate and demethylate mercury and Desulfovibrio desulfuricans G200 only able to demethylate MeHg. MeHg produced by BerOc1 increased with increasing IHg concentration with a maximum attained for 5 µM, and suggested a saturation of the process. MeHg was mainly found in the supernatant suggesting its export from the cell. Hg L3-edge High- Energy-Resolution-Fluorescence-Detected-X-ray-Absorption-Near-Edge-Structure spectroscopy (HERFD-XANES) identified MeHg produced by BerOc1 as MeHg-cysteine2 form. A dominant tetracoordinated ßHgS form was detected for BerOc1 exposed to the lowest IHg concentrations where methylation was detected. In contrast, at the highest exposure (50 µM) where Hg methylation was abolished, Hg species drastically changed suggesting a role of Hg speciation in the production of MeHg. The tetracoordinated ßHgS was likely present as nano-particles as suggested by transmission electron microscopy combined to X-ray energy dispersive spectroscopy (TEM-X-EDS) and nano-X ray fluorescence (nano-XRF). When exposed to MeHg, the production of IHg, on the contrary, increased with the increase of MeHg exposure until 50 µM for both BerOc1 and G200 strains, suggesting that demethylation did not require intact biological activity. The formed IHg species were identified as various tetracoordinated Hg-S forms. These results highlight the important role of thiol ligands and Hg coordination in Hg methylation and demethylation processes.

12.
J Synchrotron Radiat ; 27(Pt 1): 31-36, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-31868733

RESUMO

The design and performance of the high-resolution wavelength-dispersive multi-crystal von Hamos-type spectrometer at PETRA III beamline P64 are described. Extended analyzer crystal collection available at the beamline allows coverage of a broad energy range from 5 keV to 20 keV with an energy resolution of 0.35-1 eV. Particular attention was paid to enabling two-color measurements by a combination of two types of analyzer crystals and two two-dimensional detectors. The performance of the spectrometer is demonstrated by elastic-line and emission-line measurements on various compounds.

13.
Chem Rec ; 19(7): 1444-1456, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30908882

RESUMO

We designed and constructed a beamline BL36XU at the 8 GeV synchrotron radiation facility SPring-8 to provide information required for the development of next-generation polymer electrolyte fuel cells (PEFCs) by clarifying the dynamic aspects of structures and electronic states of cathode catalysts under PEFC operating conditions and in the deterioration processes by accelerated durability test protcols. To investigate the mechanism and degradation process for the cathode electrocatalysis in practical PEFCs, we developed advanced time- and spatially-resolved in-situ/operando X-ray absorption fine structure measurement systems and complementary analytical systems (X-ray emission spectroscopy (XES), X-ray diffraction (XRD), X-ray computer tomography (CT) and hard X-ray photoelectron spectroscopy (HAXPES)) and combined them to develop multi-analytical systems at BL36XU. Multi-analytical systems are very powerful for observing spatial-temporal features of the transient processes occurring in complex systems such as PEFCs. This account describes the design, performance, and research results of the BL36XU and multi-analytical in-situ/operando systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA