Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.809
Filtrar
1.
Elife ; 132024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39093938

RESUMO

The mechanism underlying the preferential and cooperative binding of cofilin and the expansion of clusters toward the pointed-end side of actin filaments remains poorly understood. To address this, we conducted a principal component analysis based on available filamentous actin (F-actin) and C-actin (cofilins were excluded from cofilactin) structures and compared to monomeric G-actin. The results strongly suggest that C-actin, rather than F-ADP-actin, represented the favourable structure for binding preference of cofilin. High-speed atomic force microscopy explored that the shortened bare half helix adjacent to the cofilin clusters on the pointed end side included fewer actin protomers than normal helices. The mean axial distance (MAD) between two adjacent actin protomers along the same long-pitch strand within shortened bare half helices was longer (5.0-6.3 nm) than the MAD within typical helices (4.3-5.6 nm). The inhibition of torsional motion during helical twisting, achieved through stronger attachment to the lipid membrane, led to more pronounced inhibition of cofilin binding and cluster formation than the presence of inorganic phosphate (Pi) in solution. F-ADP-actin exhibited more naturally supertwisted half helices than F-ADP.Pi-actin, explaining how Pi inhibits cofilin binding to F-actin with variable helical twists. We propose that protomers within the shorter bare helical twists, either influenced by thermal fluctuation or induced allosterically by cofilin clusters, exhibit characteristics of C-actin-like structures with an elongated MAD, leading to preferential and cooperative binding of cofilin.


Assuntos
Fatores de Despolimerização de Actina , Actinas , Ligação Proteica , Actinas/metabolismo , Actinas/química , Fatores de Despolimerização de Actina/metabolismo , Fatores de Despolimerização de Actina/química , Microscopia de Força Atômica , Citoesqueleto de Actina/metabolismo , Citoesqueleto de Actina/química , Conformação Proteica , Modelos Moleculares , Animais
2.
J Biomed Opt ; 29(9): 093506, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39139794

RESUMO

Significance: Minimally invasive surgery (MIS) has shown vast improvement over open surgery by reducing post-operative stays, intraoperative blood loss, and infection rates. However, in spite of these improvements, there are still prevalent issues surrounding MIS that may be addressed through hyperspectral imaging (HSI). We present a laparoscopic HSI system to further advance the field of MIS. Aim: We present an imaging system that integrates high-speed HSI technology with a clinical laparoscopic setup and validate the system's accuracy and functionality. Different configurations that cover the visible (VIS) to near-infrared (NIR) range of electromagnetism are assessed by gauging the spectral fidelity and spatial resolution of each hyperspectral camera. Approach: Standard Spectralon reflectance tiles were used to provide ground truth spectral footprints to compare with those acquired by our system using the root mean squared error (RMSE). Demosaicing techniques were investigated and used to measure and improve spatial resolution, which was assessed with a USAF resolution test target. A perception-based image quality evaluator was used to assess the demosaicing techniques we developed. Two configurations of the system were developed for evaluation. The functionality of the system was investigated in a phantom study and by imaging ex vivo tissues. Results: Multiple configurations of our system were tested, each covering different spectral ranges, including VIS (460 to 600 nm), red/NIR (RNIR) (610 to 850 nm), and NIR (665 to 950 nm). Each configuration is capable of achieving real-time imaging speeds of up to 20 frames per second. RMSE values of 3.51 ± 2.03 % , 3.43 ± 0.84 % , and 3.47% were achieved for the VIS, RNIR, and NIR systems, respectively. We obtained sub-millimeter resolution using our demosaicing techniques. Conclusions: We developed and validated a high-speed hyperspectral laparoscopic imaging system. The HSI system can be used as an intraoperative imaging tool for tissue classification during laparoscopic surgery.


Assuntos
Desenho de Equipamento , Imageamento Hiperespectral , Laparoscopia , Laparoscopia/métodos , Imageamento Hiperespectral/métodos , Animais , Humanos , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Suínos
3.
Sensors (Basel) ; 24(15)2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39123892

RESUMO

The development of systems for weighing vehicles in motion aims to introduce systems allowing automatic enforcement of regulations. HSWIM (high speed weight-in-motion) systems enable measurement of a mass of vehicles passing through a measurement station without disturbing the traffic flow. This article focuses on the calibration of a weighing station for moving vehicles, where strain gauge sensors are used to measure pressures. A solution was proposed to replace the calibration coefficients with calibration functions. The analysis was performed for two methods of determining wheel loads: based on the maximum of the signal from strain gauge sensors and on a method using the field under the signal and the vehicle's speed. Calibration functions were determined jointly for all test vehicles and separately for each of them. The use of a calibration function for a specific vehicle type made it possible to determine wheel pressure and gross weight with a level of accuracy that allowed the weigh-in-motion station to be classified as a direct enforcement system. The achieved improvement in the accuracy of weighing in motion did not require any interference with the measurement station. The proposed change in the method of calibration and, ultimately, determination of wheel loads required only a change in the algorithm for determining wheel loads.

4.
Materials (Basel) ; 17(15)2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39124408

RESUMO

The results of experimental studies in the manufacture of components of the supporting structure of the first wall panel, carried out as part of the manufacture of a model of the International Thermonuclear Experimental Reactor (ITER) using laser welding technology, are presented. The influence of laser welding modes on the quality of formation, microstructure characteristics, and mechanical properties of a welded joint made of 10 mm thick 316L steel was studied. A coaxial nozzle was designed and manufactured to protect the weld pool with a curved trajectory. The mechanical properties of the welded joint are 98-100% that of the base metal, and the microhardness of the welded joint and base metal is in the range of 180-230 HV. It was established that the lower part of the weld metal on the fusion line has transcrystalline grains and differs in δ-ferrite content; due to a high welding speed, the ratio of the depth to the width of the welding seam is 14 times. The width of the rectilinear part of the seam is 15-20% larger than its curved part.

5.
Int J Mol Sci ; 25(15)2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39125708

RESUMO

Single cilia, 100 nm in diameter and 10 µm in length, were isolated from mouse tracheae with Triton X-100 (0.02%) treatment, and the effects of pH on ciliary beating were examined by measuring the ciliary beat frequency (CBF) and the ciliary bend distance (CBD-an index of amplitude) using a high-speed video microscope (250 fps). ATP (2.5 mM) plus 8Br-cAMP (10 µM) reactivated the CBF and CBD in the isolated cilia, similar to the cilia of in vivo tracheae. In the reactivated isolated cilia, an elevation in pH from 7.0 to 8.0 increased the CBF from 3 to 15 Hz and the CBD from 0.6 to 1.5 µm. The pH elevation also increased the velocity of the effective stroke; however, it did not increase the recovery stroke, and, moreover, it decreased the intervals between beats. This indicates that H+ (pHi) directly acts on the axonemal machinery to regulate CBF and CBD. In isolated cilia priorly treated with 1 µM PKI-amide (a PKA inhibitor), 8Br-cAMP did not increase the CBF or CBD in the ATP-stimulated isolated cilia. pH modulates the PKA signal, which enhances the axonemal beating generated by the ATP-activated inner and outer dyneins.


Assuntos
Trifosfato de Adenosina , Cílios , AMP Cíclico , Traqueia , Animais , Cílios/efeitos dos fármacos , Cílios/metabolismo , Trifosfato de Adenosina/metabolismo , Concentração de Íons de Hidrogênio , Traqueia/metabolismo , Traqueia/efeitos dos fármacos , Camundongos , AMP Cíclico/metabolismo , Masculino
6.
ACS Nano ; 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39147598

RESUMO

The most reported two-dimensional (2D) reconfigurable multivalued logic (RMVL) devices primarily involve a planar configuration and carrier transport, which limits the high-density circuit integration and high-speed logic operation. In this work, the vertical transistors with reconfigurable MoTe2 homojunction are developed for low-power, high-speed, multivalued logic circuits. Through top/bottom dual-gate modulation, the transistors can be configured into four modes: P-i-N, N-i-P, P-i-P, and N-i-N. The reconfigurable rectifying and photovoltaic behaviors are observed in P-i-N and N-i-P configurations, exhibiting ideal diode characteristics with a current rectification ratio over 105 and sign-reversible photovoltaic response with a photoswitching ratio up to 7.44 × 105. Taking advantage of the seamless homogeneous integration and short vertical channel architecture, the transistor can operate as an electrical switch with an ultrafast speed of 680 ns, surpassing the conventional p-n diode. The MoTe2 half-wave rectifier is then applied in high-frequency integrated circuits using both square wave and sinusoidal waveforms. By applying an electrical pulse with a 1/4 phase difference between two input signals, the RMVL circuit has been achieved. This work proposes a universal and reconfigurable vertical transistor, enabled by dual-gate electrostatic doping on top/bottom sides of MoTe2 homojunction, suggesting a high integration device scheme for high-speed RMVL circuits and systems.

7.
Curr Biol ; 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39153483

RESUMO

Pollinator behavior is vital to plant-pollinator interactions, affecting the acquisition of floral rewards, patterns of pollen transfer, and plant reproductive success. During buzz pollination, bees produce vibrations with their indirect flight muscles to extract pollen from tube-like flowers. Vibrations can be transmitted to the flower via the mandibles, abdomen, legs, or thorax directly. Vibration amplitude at the flower determines the rate of pollen release and should vary with the coupling of bee and flower. This coupling often occurs through anther biting, but no studies have quantified how biting affects flower vibration. Here, we used high-speed filmography to investigate how flower vibration amplitude changes during biting in Bombus terrestris visiting two species of buzz-pollinated flowering plants: Solanum dulcamara and Solanum rostratum (Solanaceae). We found that floral buzzing drives head vibrations up to 3 times greater than those of the thorax, which doubles the vibration amplitude of the anther during biting compared with indirect vibration transmission when not biting. However, the efficiency of this vibration transmission depends on the angle at which the bee bites the anther. Variation in transmission mechanisms, combined with the diversity of vibrations across bee species, yields a rich assortment of potential strategies that bees could employ to access rewards from buzz-pollinated flowers.

8.
J Chromatogr A ; 1732: 465220, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39106664

RESUMO

Partial least squares (PLS) regression is a valuable chemometric tool for property prediction when coupled with gas chromatography (GC). Since the separation run time and stationary phase selection are crucial for effective PLS modeling, we study these GC parameters on the prediction of viscosity, density and hydrogen content for 50 aerospace fuels. Due to the diversity of compounds in the fuels (primarily alkanes, cycloalkanes, and aromatics), we explore both polar and non-polar stationary phase columns. The robustness for the PLS models was evaluated by their normalized root mean square error of cross-validation (NRMSECV). PLS models built for viscosity across 1-min, 3-min, 7-min, and 10-min time window (TW) high-speed GC separations produced nearly the same NRMSECV with the polar column data with an average (standard deviation) of 4.41 % (0.34 %) versus the non-polar column data of 4.69 % (0.15 %). In contrast, while the NRMSECV of density modeling with the polar column data varied more than the viscosity models, averaging 7.54 % (0.67 %), the non-polar column data produced a significantly higher average NRMSECV of 10.06 % (0.35 %). Similarly, for hydrogen content, the NRMSECV with the polar column data averaged 9.50 % (0.87 %), which was significantly lower than the NRMSECV with the non-polar column data averaging 12.10 % (0.88 %). We also investigated the impact of smoothing the GC data on the corresponding PLS models. By applying varying degrees of smoothing, we can effectively obtain similar chromatographic peak patterns in a shorter TW. For example, a 10-min smoothed chromatogram appears like the 1-min separation with no smoothing but resulted in nearly the same NRMSECV. Overall, the fast separation with a 1-min TW produced robust PLS models for viscosity with either stationary phase column, whereas for density and hydrogen content the polar stationary phase column produced superior PLS models, thus with proper stationary phase selection, a fast separation run time could be readily applied with optimal PLS property modeling results.

9.
Artigo em Inglês | MEDLINE | ID: mdl-39086551

RESUMO

Fluorescence lifetime imaging microscopy (FLIM) is a powerful imaging tool offering molecular specific insights into samples through the measurement of fluorescence decay time, with promising applications in diverse research fields. However, to acquire two-dimensional lifetime images, conventional FLIM relies on extensive scanning in both the spatial and temporal domain, resulting in much slower acquisition rates compared to intensity-based approaches. This problem is further magnified in three-dimensional imaging, as it necessitates additional scanning along the depth axis. Recent advancements have aimed to enhance the speed and three-dimensional imaging capabilities of FLIM. This review explores the progress made in addressing these challenges and discusses potential directions for future developments in FLIM instrumentation.

10.
Proc Natl Acad Sci U S A ; 121(33): e2401133121, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39102538

RESUMO

The hierarchic assembly of fibrillar collagen into an extensive and ordered supramolecular protein fibril is critical for extracellular matrix function and tissue mechanics. Despite decades of study, we still know very little about the complex process of fibrillogenesis, particularly at the earliest stages where observation of rapidly forming, nanoscale intermediates challenges the spatial and temporal resolution of most existing microscopy methods. Using video rate scanning atomic force microscopy (VRS-AFM), we can observe details of the first few minutes of collagen fibril formation and growth on a mica surface in solution. A defining feature of fibrillar collagens is a 67-nm periodic banding along the fibril driven by the organized assembly of individual monomers over multiple length scales. VRS-AFM videos show the concurrent growth and maturation of small fibrils from an initial uniform height to structures that display the canonical banding within seconds. Fibrils grow in a primarily unidirectional manner, with frayed ends of the growing tip latching onto adjacent fibrils. We find that, even at extremely early time points, remodeling of growing fibrils proceeds through bird-caging intermediates and propose that these dynamics may provide a pathway to mature hierarchic assembly. VRS-AFM provides a unique glimpse into the early emergence of banding and pathways for remodeling of the supramolecular assembly of collagen during the inception of fibrillogenesis.


Assuntos
Microscopia de Força Atômica , Imagem Individual de Molécula , Microscopia de Força Atômica/métodos , Imagem Individual de Molécula/métodos , Animais , Matriz Extracelular/metabolismo , Colágenos Fibrilares/metabolismo , Colágenos Fibrilares/química , Colágeno/metabolismo , Colágeno/química , Silicatos de Alumínio
11.
Pharm Nanotechnol ; 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39039683

RESUMO

BACKGROUND: Malaria remains a formidable public health obstacle across Africa, Southeast Asia, and portions of South America, exacerbated by resistance to antimalarial medications, such as artemisinin-based combinations. The combination of curcumin and artemisinin shows promise due to its potential for dose reduction, reduced toxicity, synergistic effects, and suitability for drug delivery improvement. OBJECTIVE: This research aims to enhance the solubility and dissolution rates of curcumin and artemisinin by employing Solid Lipid Nanoparticles (SLNs). Oral delivery of both drugs faces challenges due to their poor water solubility, inefficient absorption, and rapid metabolism and elimination. METHOD: The study focuses on formulating and optimizing Solid Lipid Nanoparticles (SLNs) encapsulating artemisinin (ART) and curcumin (CUR). SLNs were developed using the hot homogenization method, incorporating ultrasonication. Drug-excipient compatibility was evaluated using Differential Scanning Calorimetry (DSC). Lipid and surfactant screening was performed to select suitable components. A 3² full factorial design was utilized to investigate the influence of lipid and surfactant concentrations on key parameters, such as entrapment efficiency (%EE) and cumulative drug release (%CDR). Additionally, evaluations of % entrapment efficiency, drug loading, particle size, zeta potential, and in-vitro drug release were conducted. RESULTS: Successful development of artemisinin and curcumin SLNs was achieved using a full factorial design, demonstrating controlled drug release and high entrapment efficiency. The optimized nanoparticles exhibited a size of 114.7nm, uniformity (PDI: 0.261), and a zeta potential of -9.24 mV. Artemisinin and curcumin showed %EE values of 79.1% and 74.5%, respectively, with cumulative drug release of 85.1% and 80.9%, respectively. The full factorial design indicated that increased lipid concentration improved %EE, while higher surfactant concentration enhanced drug release and %EE. Stability studies of the optimized batch revealed no alterations in physical or chemical characteristics. CONCLUSION: The study successfully developed Solid Lipid Nanoparticles (SLNs) for artemisinin and curcumin, achieving controlled drug release, high entrapment efficiency, and desired particle size and uniformity. This advancement holds promise for enhancing drug delivery of herbal formulations.

12.
F1000Res ; 13: 360, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39045173

RESUMO

Invasive plant species pose ecological threats to native ecosystems, particularly in areas adjacent to roadways, considering that roadways represent lengthy corridors through which invasive species can propagate. Traditional manual survey methods for monitoring invasive plants are labor-intensive and limited in coverage. This paper introduces a high-speed camera system, named CamAlien, designed to be mounted on vehicles for efficient invasive plant species monitoring along roadways. The camera system captures high-quality images at rapid intervals, to monitor the full roadside when following traffic speed. The system utilizes a global shutter sensor to reduce distortion and geotagging for precise localistion. The camera system makes it possible to collect extensive data sets, which can be used for a digital library of the invasive species and their locations, but also subsequent training of machine learning algorithms for automated species recognition.


Assuntos
Espécies Introduzidas , Plantas , Monitoramento Ambiental/métodos , Monitoramento Ambiental/instrumentação , Fotografação/instrumentação , Fotografação/métodos , Ecossistema
13.
Phytochem Anal ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38957046

RESUMO

INTRODUCTION: Sophora flavescens Aiton (Fabaceae), a ubiquitous plant species in Asia, contains a wide range of pharmacologically active compounds, such as flavonoids, with potential anti-Alzheimer's disease (anti-AD) effects. OBJECTIVES: The objective of the study is to develop a quaternity method for the screening, isolation, extraction optimization, and activity evaluation of acetylcholinesterase (AChE)-inhibiting compounds from S. flavescens to realize high-throughput screening of active substances in traditional Chinese medicine and to provide experimental data for the development of anti-AD drugs. METHODS: With AChE as the target molecule, affinity ultrafiltration and liquid chromatography-mass spectrometry were applied to screen for potential inhibitors of the enzyme in S. flavescens. Orthogonal array experiments combined with the multi-objective Non-Dominated Sorting Genetic Algorithm III was used for the first time to optimize the process for extracting the active substances. Enzyme inhibition kinetics and molecular docking studies were performed to verify the potential anti-AD effects of the active compounds. RESULTS: Five AChE-inhibiting compounds were identified: kushenol I, kurarinone, sophoraflavanone G, isokurarinone, and kushenol E. These were successfully separated at purities of 72.88%, 98.55%, 96.86%, 96.74%, and 95.84%, respectively, using the n-hexane/ethyl acetate/methanol/water (4.0/5.0/4.0/5.0, v/v/v/v), n-hexane/ethyl acetate/methanol/water (5.0/5.0/6.0/4.0, v/v/v/v), and n-hexane/ethyl acetate/methanol/water (4.9/5.1/5.7/4.3, v/v/v/v) mobile phase systems. Enzyme inhibition kinetics revealed that kushenol E had the best inhibitory effect. CONCLUSION: This study elucidates the mechanism of action of five active AChE inhibitors in S. flavescens and provides a theoretical basis for the screening and development of anti-AD and other therapeutic drugs.

14.
J Voice ; 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39003213

RESUMO

OBJECTIVES: This study aimed to estimate vocal loading in loud phonation of a vowel and two widely used semiocclusion voice exercises (SOVTEs). Impact stress (IS) was estimated from glottal closing speed, inertial forces from the second derivative of glottal opening and closing. STUDY DESIGN: Experimental study in vivo. METHODS: A vocally healthy male sustained the [o:] vowel with habitual loudness and loudly: (1) without a tube, (2) into a silicone "Lax Vox" type tube (35 cm in length, 10 mm in diameter) outer end submerged 10 cm in water, and (3) into a straw (length 12.6 cm, diameter 2.5 mm) the outer end in air. He tried to use equal effort in all loud samples. High-speed video-laryngo-endoscopy was performed with a rigid scope. Oral air pressure (Poral) was registered in a mouthpiece through which the endoscope was inserted into the larynx and to which the tubes were attached air-tightly. RESULTS: Compared with vowel phonation at habitual loudness, mean of maximal glottal width (max GW) increased by 44.1% for loud tube phonation and decreased by 1.8% for loud straw phonation, and mean absolute value of minimum GW time derivative dmin increased by 57.1% for tube and by 29.5% for straw suggesting faster glottal closing. Compared with loud vowel phonation, max GW increased by 22.6% for loud tube phonation, while it decreased by 16.6% for loud straw phonation. For the tube, dmindecreased by 7.6% and for the straw by 23.8%. Maximal acceleration (ACC) and deceleration (DC) values were larger for the tube and smaller for the straw than the values for both vowel phonations. CONCLUSIONS: IS, deduced from dmin, increased in loud SOVTEs compared to vowel phonation at a conversational loudness, but remained lower in loud SOVTEs than in loud vowel phonation, particularly with a narrow straw, which also reduced inertial forces, as suggested by the reduced ACC and DC.

15.
Sci Rep ; 14(1): 15901, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38987266

RESUMO

The rapid development of the logistics industry has driven innovations in parcel sorting technology, among which the swift and precise positioning and classification of parcels have become key to enhancing the performance of logistics systems. This study aims to address the limitations of traditional light curtain positioning methods in logistics sorting workshops amidst high-speed upgrades. This paper proposes a high-speed classification and location algorithm for logistics parcels utilizing a monocular camera. The algorithm combines traditional visual processing methods with an enhanced version of the lightweight YOLOv5 object detection algorithm, achieving high-speed, high-precision parcel positioning. Through the adjustment of the network structure and the incorporation of new feature extraction modules and ECIOU loss functions, the model's robustness and detection accuracy have been significantly improved. Experimental results demonstrate that this model exhibits outstanding performance on a customized logistics parcel dataset, notably enhancing the model's parameter efficiency and computational speed, thereby offering an effective solution for industrial applications in high-speed logistics supply.

16.
Data Brief ; 55: 110582, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39006353

RESUMO

Boiling is a high-performance heat dissipation process that is central to electronics cooling and power generation. However, there exists a practical limit of boiling heat transfer known as the critical heat flux (CHF), beyond which significant performance degradation is observed. Understanding the physical mechanism that triggers CHF is essential to meet the increasing cooling demands driven by power densification and device miniaturization. However, the high dimensionality, stochasticity, and dynamicity of the boiling process have led to strong challenges in the experimental characterization and modeling of boiling CHF. As such, high-frame rate, high-resolution, multi-physics boiling datasets are critical to advancing the fundamental understanding of boiling heat transfer. To this end, this paper presents a multimodal boiling dataset consisting of synchronized thermal, acoustic, and optical signals collected from five different heater surfaces under two distinct heat load conditions. With its high sampling frequency, diverse signal types, large data volume, and detailed recorded information, this dataset provides valuable "data blood" for the field of thermal crisis monitoring. This dataset will not only promote fundamental research on bubble dynamics during boiling but also support the implementation of advanced monitoring technologies in industrial applications such as power electronics, motors, data centers, and power plants.

17.
Nanomaterials (Basel) ; 14(13)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38998745

RESUMO

The graphene adjustable-barriers phototransistor is an attractive novel device for potential high speed and high responsivity dual-band photodetection. In this device, graphene is embedded between the semiconductors silicon and germanium. Both n-type and p-type Schottky contacts between graphene and the semiconductors are required for this device. While n-type Schottky contacts are widely investigated, reports about p-type Schottky contacts between graphene and the two involved semiconductors are scarce. In this study, we demonstrate a p-type Schottky contact between graphene and p-germanium. A clear rectification with on-off ratios of close to 103 (±5 V) and a distinct photoresponse at telecommunication wavelengths in the infrared are achieved. Further, p-type silicon is transferred to or deposited on graphene, and we also observe rectification and photoresponse in the visible range for some of these p-type Schottky junctions. These results are an important step toward the realization of functional graphene adjustable-barrier phototransistors.

18.
Sensors (Basel) ; 24(13)2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-39001000

RESUMO

We present a novel photon-acid diffusion method to integrate polymer microlenses (MLs) on a four-channel, high-speed photo-receiver consisting of normal-incidence germanium (Ge) p-i-n photodiodes (PDs) fabricated on a 200 mm Si substrate. For a 29 µm diameter PD capped with a 54 µm diameter ML, its dark current, responsivity, 3 dB bandwidth (BW), and effective aperture size at -3 V bias and 850 nm wavelength are measured to be 138 nA, 0.6 A/W, 21.4 GHz, and 54 µm, respectively. The enlarged aperture size significantly decouples the tradeoff between aperture size and BW and enhances the optical fiber misalignment tolerance from ±5 µm to ±15 µm to ease the module packaging precision. The sensitivity of the photo-receiver is measured to be -9.2 dBm at 25.78 Gb/s with a bit error rate of 10-12 using non-return-to-zero (NRZ) transmission. Reliability tests are performed, and the results show that the fabricated Ge PDs integrated with polymer MLs pass the GR-468 reliability assurance standard. The demonstrated photo-receiver, a first of its kind to the best of our knowledge, features decent performance, high yield, high throughput, low cost, and compatibility with complementary metal-oxide-semiconductor (CMOS) fabrication processes, and may be further applied to 400 Gb/s pulse-amplitude modulation four-level (PAM4) communication.

19.
Sensors (Basel) ; 24(13)2024 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-39001182

RESUMO

Track geometry measurements (TGMs) are a critical methodology for assessing the quality of track regularities and, thus, are essential for ensuring the safety and comfort of high-speed railway (HSR) operations. TGMs also serve as foundational datasets for engineering departments to devise daily maintenance and repair strategies. During routine maintenance, S-shaped long-wave irregularities (SLIs) were found to be present in the vertical direction from track geometry cars (TGCs) at the beginning and end of a vertical curve (VC). In this paper, we conduct a comprehensive analysis and comparison of the characteristics of these SLIs and design a long-wave filter for simulating inertial measurement systems (IMSs). This simulation experiment conclusively demonstrates that SLIs are not attributed to track geometric deformation from the design reference. Instead, imperfections in the longitudinal profile's design are what cause abrupt changes in the vehicle's acceleration, resulting in the measurement output of SLIs. Expanding upon this foundation, an additional investigation concerning the quantitative relationship between SLIs and longitudinal profiles is pursued. Finally, a method that involves the addition of a third-degree parabolic transition curve (TDPTC) or a full-wave sinusoidal transition curve (FSTC) is proposed for a smooth transition between the slope and the circular curve, designed to eliminate the abrupt changes in vertical acceleration and to mitigate SLIs. The correctness and effectiveness of this method are validated through filtering simulation experiments. These experiments indicate that the proposed method not only eliminates abrupt changes in vertical acceleration, but also significantly mitigates SLIs.

20.
Sensors (Basel) ; 24(13)2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-39001192

RESUMO

As a non-contact method, vision-based measurement for vibration extraction and modal parameter identification has attracted much attention. In most cases, artificial textures are crucial elements for visual tracking, and this feature limits the application of vision-based vibration measurement on textureless targets. As a computation technique for visualizing subtle variations in videos, the video magnification technique can analyze modal responses and visualize modal shapes, but the efficiency is low, and the processing results contain clipping artifacts. This paper proposes a novel method for the application of a modal test. In contrast to the deviation magnification that exaggerates subtle geometric deviations from only a single image, the proposed method extracts vibration signals with sub-pixel accuracy on edge positions by changing the perspective of deviations from space to timeline. Then, modal shapes are visualized by decoupling all spatial vibrations following the vibration theory of continuous linear systems. Without relying on artificial textures and motion magnification, the proposed method achieves high operating efficiency and avoids clipping artifacts. Finally, the effectiveness and practical value of the proposed method are validated by two laboratory experiments on a cantilever beam and an arch dam model.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA