Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int J Hyg Environ Health ; 222(3): 347-354, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30638980

RESUMO

Indoor air quality (IAQ) and exposure to indoor chemicals are widely discussed in terms of personal discomfort and health risks. In contrast to ambient air and working environments, legally binding regulations are only partially established for indoor contaminants, and other available European guidelines are limited. To correct these deficits, the German Committee on Indoor Guide Values (AIR), formerly known as the Ad hoc Working Group (Ad hoc AG), performed health assessments of indoor air contaminants. The main tasks were to develop toxicologically based indoor air guide values, health-based guideline values, and reference values largely based on the 95th percentile of the concentrations found in a reference population. Here, we provide a comprehensive overview of the indoor air values set in Germany and discuss the basis of their derivation. This overview includes a description of legally binding standards, indoor air guide values for 38 substances or groups, and guidelines for TVOC (total volatile organic compounds), particulate matter, and carbon dioxide as well as risk-related guidelines for carcinogenic substances.


Assuntos
Poluição do Ar em Ambientes Fechados/legislação & jurisprudência , Poluição do Ar em Ambientes Fechados/prevenção & controle , Exposição por Inalação/legislação & jurisprudência , Exposição por Inalação/prevenção & controle , Poluentes Atmosféricos/análise , Poluentes Atmosféricos/normas , Alemanha , Regulamentação Governamental , Humanos , Exposição por Inalação/análise , Exposição por Inalação/normas , Concentração Máxima Permitida
2.
Indoor Air ; 25(1): 93-104, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24809924

RESUMO

This research assesses benefits of adding to California Title-24 ventilation rate (VR) standards a performance-based option, similar to the American Society of Heating, Refrigerating, and Air Conditioning Engineers 'Indoor Air Quality Procedure' (IAQP) for retail spaces. Ventilation rates and concentrations of contaminants of concern (CoC) were measured in 13 stores. Mass balance models were used to estimate 'IAQP-based' VRs that would maintain concentrations of all CoCs below health- or odor-based reference concentration limits. An intervention study in a 'big box' store assessed how the current VR, the Title 24-prescribed VR, and the IAQP-based VR (0.24, 0.69, and 1.51 air changes per hour) influenced measured IAQ and perceived of IAQ. Neither current VRs nor Title 24-prescribed VRs would maintain all CoCs below reference limits in 12 of 13 stores. In the big box store, the IAQP-based VR kept all CoCs below limits. More than 80% of subjects reported acceptable air quality at all three VRs. In 11 of 13 buildings, saving energy through lower VRs while maintaining acceptable IAQ would require source reduction or gas-phase air cleaning for CoCs. In only one of the 13 retail stores surveyed, application of the IAQP would have allowed reduced VRs without additional contaminant-reduction strategies.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Ventilação/normas , Adolescente , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Aldeídos/análise , California , Comércio , Monitoramento Ambiental/métodos , Feminino , Inquéritos Epidemiológicos , Humanos , Masculino , Percepção , Compostos Orgânicos Voláteis/análise , Adulto Jovem
3.
Indoor Air ; 25(3): 307-19, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24995998

RESUMO

The main objective of this study was to examine the performance of protected zone ventilation (PZV) and hybrid protected zone ventilation (HPZV) to reduce the direct exposure to exhaled air from others' breathing. Experimental measurements are carried out to test the performance of PZV in a full-scale office room with two breathing thermal manikins. The measurements were performed under three configurations, including two standing manikins at different distances: 0.35, 0.5, and 1.1 m. When the supply air velocity is increased to 4 m/s in the downward plane jet, the dimensionless concentration is 40% lower than for fully mixed ventilation, which can be considered as a measure of protection from the zoning condition. The measurement results showed that in both the PZV and the HPZV system it is possible to decrease the transmission of tracer gas from one manikin to the opposite manikin; therefore, it probably would reduce the risk of air borne cross-infection between two people at the same relative positions. The results suggest that PZV and HPZV may be used to reduce the exposure of people in a protected zone from indoor pollutants emitted in a source zone.


Assuntos
Infecção Hospitalar/prevenção & controle , Exposição por Inalação/prevenção & controle , Respiração , Ventilação/métodos , Movimentos do Ar , Infecção Hospitalar/etiologia , Expiração , Humanos , Exposição por Inalação/efeitos adversos , Manequins
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA