Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Clin Med ; 13(10)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38792446

RESUMO

The controlled dynamization of fractures can promote natural fracture healing by callus formation, while overly rigid fixation can suppress healing. The advent of locked plating technology enabled new strategies for the controlled dynamization of fractures, such as far cortical locking (FCL) screws or active plates with elastically suspended screw holes. However, these strategies did not allow for the use of non-locking screws, which are typically used to reduce bone fragments to the plate. This study documents the first in vivo study on the healing of ovine tibia osteotomies stabilized with an advanced active plate (AAP). This AAP allowed plate application using any combination of locking and non-locking screws to support a wide range of plate application techniques. At week 9 post-surgery, tibiae were harvested and tested in torsion to failure to assess the healing strength. The five tibiae stabilized with an AAP regained 54% of their native strength and failed by spiral fracture through a screw hole, which did not involve the healed osteotomy. In comparison, tibiae stabilized with a standard locking plate recovered 17% of their strength and sustained failure through the osteotomy. These results further support the stimulatory effect of controlled motion on fracture healing. As such, the controlled dynamization of locked plating constructs may hold the potential to reduce healing complications and may shorten the time to return to function. Integrating controlled dynamization into fracture plates that support a standard fixation technique may facilitate the clinical adoption of dynamic plating.

2.
Comput Methods Programs Biomed ; 244: 107996, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38176328

RESUMO

BACKGROUND: Interfragmentary motion (IFM) is a complex state that significantly impacts the healing process of fractures following implant placement. It is crucial to fully consider the IFM state after implantation in the design and biomechanical testing of implants. However, current finite element analysis software lacks direct tools for calculating IFM, and existing IFM tools do not offer a comprehensive solution in terms of accuracy, functionality, and visualization. METHODS: In our study, we developed a Python-based algorithm for calculating IFM that addresses limitations. Our algorithm automatically calculated IFM distances, sliding distances, gaps, as well as the angles and rotation of the two fracture surfaces using all nodes on both sides of the fracture ends. Researchers could input data and selected desired parameters in the interface. The algorithm then performed the necessary calculations and presented the results in a clear and concise manner. The algorithm also provided comprehensive data export capabilities, allowing researchers to customize analyses based on specific needs.To provide a more intuitive demonstration of the calculation process and usage of IFM-Cal, we conducted simulations in Ansys using two rectangular blocks to compare the accuracy and function of three different methods (Point based method, contact tool and IFM-Cal). RESULTS: The point-based method and the contact tool could not accurately calculate IFA, while IFM-Cal could provide a comprehensive evaluation of IFA. In simulation 1, the IFM distances calculated using the point sampling method, contact tool, and IFM-Cal were 2.00 mm, 3.15 mm, and 2.00 mm, respectively. In simulation 2, both the point sampling method and contact tool failed to calculate the interfragmentary angle (IFA), while the IFM-Cal algorithm estimated an angle of -7.87°, which had a small error compared to the ground-truth value of 7.9°. CONCLUSION: We have developed an algorithm for computing IFM which can be utilized in finite element analysis and biomechanical experiments. By conducting comparative simulations with other existing algorithms, we have demonstrated the superior accuracy and expanded evaluation capabilities of our algorithm.


Assuntos
Fraturas Ósseas , Humanos , Análise de Elementos Finitos , Cicatrização , Rotação , Algoritmos , Fenômenos Biomecânicos
3.
Front Bioeng Biotechnol ; 11: 1199944, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37388773

RESUMO

Background: Complex bone plateau fractures have been treated with bilateral plate fixation, but previous research has overemphasized evaluating the effects of internal fixation design, plate position, and screw orientation on fracture fixation stability, neglecting the internal fixation system's biomechanical properties in postoperative rehabilitation exercises. This study aimed to investigate the mechanical properties of tibial plateau fractures after internal fixation, explore the biomechanical mechanism of the interaction between internal fixation and bone, and make suggestions for early postoperative rehabilitation and postoperative weight-bearing rehabilitation. Methods: By establishing the postoperative tibia model, the standing, walking and running conditions were simulated under three axial loads of 500 N, 1000 N, and 1500 N. Accordingly, finite element analysis (FEA) was performed to analyze the model stiffness, displacement of fractured bone fragments, titanium alloy plate, screw stress distribution, and fatigue properties of the tibia and the internal fixation system under various conditions. Results: The stiffness of the model increased significantly after internal fixation. The anteromedial plate was the most stressed, followed by the posteromedial plate. The screws at the distal end of the lateral plate, the screws at the anteromedial plate platform and the screws at the distal end of the posteromedial plate are under greater stress, but at a safe stress level. The relative displacement of the two medial condylar fracture fragments varied from 0.002-0.072 mm. Fatigue damage does not occur in the internal fixation system. Fatigue injuries develop in the tibia when subjected to cyclic loading, especially when running. Conclusion: The results of this study indicate that the internal fixation system tolerates some of the body's typical actions and may sustain all or part of the weight early in the postoperative period. In other words, early rehabilitative exercise is recommended, but avoid strenuous exercise such as running.

4.
Front Bioeng Biotechnol ; 11: 1172013, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37229497

RESUMO

Objective: To evaluate the biomechanical effects of Poller screws (PS) combined with small-diameter intramedullary nails in the treatment of distal tibial fractures at different locations and on different planes. Methods: Nine finite element (FE) models were used to simulate the placement of the intramedullary nail (IMN) and the PS for distal tibial fractures. Structural stiffness and interfragmentary motion (IFM) through the fracture were investigated to assess the biomechanical effects of the PS. The allowable stress method was used to evaluate the safety of the construct. Results: With the axial load of 500 N, the mean axial stiffness of IMN group was 973.38 ± 95.65 N/mm, which was smaller than that at positions A and B of the coronal group and sagittal group (p < 0.05). The shear IFM of the IMN group was 2.10 ± 0.02 mm, which were smaller than that at positions A and B of the coronal group and sagittal group (p < 0.05). Under physiological load, the stresses of all internal fixation devices and the nail-bone interface were within a safe range. Conclusion: In the treatment of distal tibial fractures, placing the PS in the proximal fracture block can obtain better biomechanical performance. The IMN fixation system can obtain higher structural stiffness and reduce the IFM of the fracture end by adding PS.

5.
J Arthroplasty ; 38(7S): S292-S297, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36933680

RESUMO

BACKGROUND: Due to increasing volume of total hip arthroplasties, periprosthetic femoral fractures have become a common complication with increased revision burden and perioperative morbidity. The objective of this study was to evaluate the fixation stability of Vancouver B2 fractures treated with 2 techniques. METHODS: A common B2 fracture was created by reviewing 30 type B2 cases. The fracture was then reproduced in 7 pairs of cadaveric femora. The specimens were divided into 2 groups. In Group I ("reduce-first"), the fragments were reduced first, followed by implantation of a tapered fluted stem. In Group II ("ream-first"), the stem was implanted in the distal femur first, followed by fragment reduction and fixation. Each specimen was loaded in a multiaxial testing frame with 70% of peak load during walking. A motion capture system was used to track the motion of the stem and fragments. RESULTS: The average stem diameter in Group II was 16.1 ± 0.4 mm, versus 15.4 ± 0.5 mm in Group I. The fixation stability was not significantly different in the 2 groups. After the testing, the average stem subsidence was 0.36 ± 0.31 mm and 0.19 ± 0.14 mm (P = .17) and the average rotation was 1.67 ± 1.30° and 0.91 ± 1.11° (P = .16) in Groups I and II, respectively. Compared to the stem, there was less motion of the fragments and there was no difference between the 2 groups (P > .05). CONCLUSIONS: When tapered fluted stems were used in combination with cerclage cables for treatment of Vancouver type B2 periprosthetic femoral fractures, both the "reduce-first" and "ream-first" techniques showed adequate stem and fracture stability.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Prótese de Quadril/efeitos adversos , Reoperação/efeitos adversos , Resultado do Tratamento , Artroplastia de Quadril/efeitos adversos , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/complicações , Fêmur/cirurgia , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Estudos Retrospectivos
6.
J Clin Med ; 11(11)2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35683515

RESUMO

BACKGROUND: Acromial Levy III fractures after inverse shoulder arthroplasty occur in up to 7% of patients. To date, it is not clear how these fractures should be treated as clinical outcomes remain unsatisfactory. The aim of this study was to evaluate the biomechanical performance of three different plating methods of type III acromion fractures. METHODS: Levy III fractures in synthetic scapulae were fixed with three different methods. Angular stable locking plates were placed on the spina scapula to bridge the fracture either dorsally, caudally, or on both aspects by double plating. In a biomechanical experiment, the pull of the deltoid muscle at 40° abduction of the arm was simulated by cyclic loading with increasing load levels until failure. Failure load, cycles to failure, and fragment motions were evaluated. RESULTS: The results showed that double plating (350 ± 63 N) withstood the highest loads until failure, followed by dorsal (292 ± 20 N) and caudal (217 ± 49 N) plating. Similarly, double plating showed significantly smaller fragment movement than the other two groups. CONCLUSIONS: Double plating appeared to provide the largest biomechanical stability in type III acromion fracture under arm abduction. Caudal plating in contract resulted in insufficient fracture stability and early failure and can thus not be recommended from a biomechanical point of view.

7.
OTA Int ; 5(1 Suppl): e164, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35282393

RESUMO

Objectives: Current surgical fracture treatment paradigms, which use rigid metallic constructs to heal bones, provide reasonable clinical outcomes; however, they do not leverage recent advances in our understanding of bone healing and mechanotransduction throughout bone healing. The objective of this review was to investigate the efficacy and potential clinical applicability of surgical techniques and implants that deliberately introduce interfragmentary motion throughout the healing process. Methods: The authors searched PubMed and Google Scholar databases for articles reporting on fracture repair using dynamic locking plates, dynamized surgical techniques, and reverse dynamization. Data collection also included assessment of additively manufactured (AM) implants that provide dynamic mechanical behaviors. Results: Forty articles were included for final review. It was found that accelerated rates of fracture healing can be achieved with staged 2-part surgeries or dynamic implant designs. Temporal dynamization, where static fixation of bones is followed by the introduction of micromotion and controlled loading, has been shown to improve callus volume and accelerate the healing response. Reverse dynamization, where micromotion is encouraged during early callus formation and arrested later, may represent a significant advance for the treatment of critical defect injuries. Advances in AM techniques will likely provide the ability to create high-resolution implants capable of dynamized and reverse dynamized modalities. Conclusions: There is no one-size-fits-all approach to optimization of fracture healing. However, it has been clearly demonstrated that fracture treatment can be enhanced by systematically altering the construct stiffness throughout the different phases of healing, which may be achieved with AM implant designs.

8.
J Orthop Res ; 39(8): 1669-1680, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33034914

RESUMO

Vertical femoral neck fractures in patients younger than 65 years of age often require hip-conserving surgeries. However, traditional fixation strategies using three parallel cannulated screws often fail in such patients due to an unfavorable biomechanical environment. This study compared different cannulated screw fixation techniques in patients via patient-specific finite element analysis with linear tetrahedral (C3D4) elements. Forty vertical femoral neck fracture models were created based on computed tomography images obtained from eight healthy participants. Five different fixation strategies: alpha, buttress, rhomboid, inverted triangle, and triangle were assessed in walking status. Biomechanical parameters including stiffness, interfragmentary motion in two directions (detachment and shearing), compression force, and maximal implant stress were evaluated. The mean relative coefficient of strain distribution between the finite element analysis and experiment was from 0.78 to 0.94. Stiffness was highest (p < .05) in the buttress group (923.1 N/mm), while interfragmentary motion was lowest (p < .05) in the alpha group. Maximal stress was highest (p < .05) in the buttress group and lowest in the alpha group. Shearing values were significantly lower in the alpha group than in the rhomboid group (p = .004). Moreover, Shearing values were significantly higher (p = .027), while detachment values were significantly lower (p = .027), in the inverted triangle than in the triangle group. Clinical significance: Our results suggest that alpha fixation is the most reliable and biomechanically efficient strategy for young patients with vertical femoral neck fractures. Regular and inverted triangular fixation strategies may be suitable for fractures of different skeletal constructions due to antidetachment/shearing abilities.


Assuntos
Fraturas do Colo Femoral , Fenômenos Biomecânicos , Parafusos Ósseos , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Análise de Elementos Finitos , Fixação Interna de Fraturas/métodos , Humanos
9.
Front Bioeng Biotechnol ; 8: 593448, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33520953

RESUMO

Fixing bone fractures with controlled axial interfragmentary micromotion improves bone healing; however, the optimal type of implant construct for this purpose is still lacking. The present study describes a novel axial micromotion locking plate (AMLP) construct that allows axial interfragmentary micromotion of 0.3 or 0.6 mm. We investigated whether the AMLP constructs enhance bone healing compared to an ordinary locking plate (LP) using an ovine osteotomy model. The stiffness of the constructs was tested under axial loading. We created a 3-mm osteotomy in the left hind leg tibia of sheep that was then stabilized with a 0.3- or 0.6-mm AMLP or LP construct (n = 6/group). Bone healing was monitored weekly by X-ray radiography starting from week 3 after surgery. At week 9, the specimens were collected and evaluated by computed tomography and torsional testing. We found that the AMLPs had a lower stiffness than the LP; in particular, the stiffness of the 0.6-mm AMLP construct was 86 and 41% lower than that of the LP construct for axial loads <200 and >200 N, respectively. In the in vivo experiments, tibial osteotomies treated with the 0.6-mm AMLP construct showed the earliest maximum callus formation (week 5) and the highest volume of bone callus (9.395 ± 1.561 cm3 at week 9). Specimens from this group also withstood a 27% greater torque until failure than those from the LP group (P = 0.0386), with 53% more energy required to induce failure (P = 0.0474). These results demonstrate that AMLP constructs promote faster and stronger bone healing than an overly rigid LP construct. Moreover, better bone healing was achieved with an axial micromotion of 0.6 mm as compared to 0.3 mm.

10.
Injury ; 49 Suppl 1: S12-S18, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29929685

RESUMO

Most locked plating failures are due to inappropriate device configuration for the fracture pattern. Several studies cite screw positioning variables such as the number and spacing of screws as responsible for occurrences of locking plate breakage, screw loosening, and peri-prosthetic re-fracture. It is also widely accepted that inappropriate device stiffness can inhibit or delay healing. Careful preoperative planning is therefore critical if these failures are to be prevented. This study examines several variables which need to be considered when optimising a locking plate fixation device for fracture treatment including: material selection; screw placement; the effect of the fracture pattern; and the bone-plate offset. We demonstrate that device selection is not straight-forward as many of the variables influence one-another and an identically configured device can perform very differently depending upon the fracture pattern. Finally, we summarise the influence of some of the key parameters and the influence this can have on the fracture healing environment and the stresses within the plate in a flowchart.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Cuidados Pré-Operatórios , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Tomada de Decisões , Análise de Falha de Equipamento , Análise de Elementos Finitos , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura , Humanos , Teste de Materiais
11.
Knee Surg Sports Traumatol Arthrosc ; 26(3): 756-761, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28255659

RESUMO

PURPOSE: The role of the proximal tibiofibular joint (PTFJ) in tibial plateau fractures is unknown. The purpose of this study was to assess, with finite-element (FE) calculations, differences in interfragmentary movement (IFM) in a split fracture of lateral tibial plateau, with and without intact fibula. It was hypothesized that an intact fibula could positively contribute to the mechanical stabilization of surgically reduced lateral tibial plateau fractures. METHODS: A split fracture of the lateral tibial plateau was recreated in an FE model of a human tibia. A three-dimensional FE model geometry of a human femur-tibia system was obtained from the VAKHUM project database, and was built from CT images from a subject with normal bone morphologies and normal alignment. The mesh of the tibia was reconverted into a geometry of NURBS surfaces. The fracture was reproduced using geometrical data from patient radiographs, and two models were created: one with intact fibula and other without fibula. A locking screw plate and cannulated screw systems were modelled to virtually reduce the fracture, and 80 kg static body weight was simulated. RESULTS: Under mechanical loads, the maximum interfragmentary movement achieved with the fibula was about 30% lower than without fibula, with both the cannulated screws and the locking plate. When the locking plate model was loaded, intact fibula contributed to lateromedial forces on the fractured fragments, which would be clinically translated into increased normal compression forces in the fractured plane. The intact fibula also reduced the mediolateral forces with the cannulated screws, contributing to stability of the construct. CONCLUSION: This FE model showed that an intact fibula contributes to the mechanical stability of the lateral tibial plateau. In combination with a locking plate fixation, early weight bearing may be allowed without significant IFM, contributing to an early clinical and functional recovery of the patient.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fíbula/cirurgia , Fixação Interna de Fraturas/métodos , Tíbia/lesões , Fraturas da Tíbia/cirurgia , Suporte de Carga , Fíbula/diagnóstico por imagem , Fíbula/lesões , Humanos , Imageamento Tridimensional , Radiografia , Tíbia/diagnóstico por imagem , Tíbia/fisiopatologia , Fraturas da Tíbia/diagnóstico , Fraturas da Tíbia/fisiopatologia
12.
J Orthop Res ; 34(11): 1856-1864, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-26872689

RESUMO

When using locked plating for bone fracture fixation, screw loosening is reported as one of the most frequent complications and is commonly attributed to an incorrect choice of screw configuration. Choosing a patient-optimized screw configuration is not straightforward as there are many interdependent variables that affect device performance. The aim of the study was to evaluate the influence that locking screw configuration has on loosening risk and how this is influenced by bone quality. This study uses finite element models that incorporate cortical bone heterogeneity, orthotropy, and geometrical nonlinearity to examine the effect of screw configuration on variables associated with loosening and interfragmentary motion. Strain levels within the bone were used as indicators of regions that may undergo loosening. The study found that, in healthy bone under axial loading, the most important variables influencing strain levels within the bone were the size of the bridging span (working length) and the plate rigidity. Unlike healthy bone, osteoporotic bone was found to be particularly sensitive to the spacing of the screws within the plate. Using two empty screw holes between the screws closest to the fracture was found to reduce the strain levels at the first screw by 49% in osteoporotic bone (compared to only 2.4% in healthy bone). The study also found that under torsional loading the total number of screws used was the most important variable with a 59% reduction in the strain around the screws closest to the fracture when using six rather than four screws in osteoporotic bone. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1856-1864, 2016.


Assuntos
Parafusos Ósseos/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Fatores Etários , Análise de Elementos Finitos , Humanos
13.
Int Orthop ; 40(10): 2163-2169, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26780714

RESUMO

PURPOSE: To assess, with finite element (FE) calculations, whether immediate weight bearing would be possible after surgical stabilization either with cannulated screws or with a locking plate in a split fracture of the lateral tibial plateau (LTP). METHODS: A split fracture of the LTP was recreated in a FE model of a human tibia. A three-dimensional FE model geometry of a human femur-tibia system was obtained from the VAKHUM project database, and was built from CT images from a subject with normal bone morphologies and normal alignment. The mesh of the tibia was reconverted into a geometry of NURBS surfaces. A split fracture of the lateral tibial plateau was reproduced by using geometrical data from patient radiographs. A locking screw plate (LP) and a cannulated screw (CS) systems were modelled to virtually reduce the fracture and 80 kg static body-weight was simulated. RESULTS: While the simulated body-weight led to clinically acceptable interfragmentary motion, possible traumatic bone shear stresses were predicted nearby the cannulated screws. With a maximum estimation of about 1.7 MPa maximum bone shear stresses, the Polyax system might ensure more reasonable safety margins. CONCLUSIONS: Split fractures of the LTP fixed either with locking screw plate or cannulated screws showed no clinically relevant IFM in a FE model. The locking screw plate showed higher mechanical stability than cannulated screw fixation. The locking screw plate might also allow full or at least partial weight bearing under static posture at time zero.


Assuntos
Fixação Interna de Fraturas/instrumentação , Fraturas da Tíbia/cirurgia , Placas Ósseas , Parafusos Ósseos , Análise de Elementos Finitos , Fixação Interna de Fraturas/métodos , Humanos , Fraturas da Tíbia/fisiopatologia , Suporte de Carga
14.
J Biomech ; 48(15): 3989-3994, 2015 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-26477405

RESUMO

Successful healing of long bone fractures is dependent on the mechanical environment created within the fracture, which in turn is dependent on the fixation strategy. Recent literature reports have suggested that locked plating devices are too stiff to reliably promote healing. However, in vitro testing of these devices has been inconsistent in both method of constraint and reported outcomes, making comparisons between studies and the assessment of construct stiffness problematic. Each of the methods previously used in the literature were assessed for their effect on the bending of the sample and concordant stiffness. The choice of outcome measures used in in vitro fracture studies was also assessed. Mechanical testing was conducted on seven hole locked plated constructs in each method for comparison. Based on the assessment of each method the use of spherical bearings, ball joints or similar is suggested at both ends of the sample. The use of near and far cortex movement was found to be more comprehensive and more accurate than traditional centrally calculated interfragmentary movement values; stiffness was found to be highly susceptible to the accuracy of deformation measurements and constraint method, and should only be used as a within study comparison method. The reported stiffness values of locked plate constructs from in vitro mechanical testing is highly susceptible to testing constraints and output measures, with many standard techniques overestimating the stiffness of the construct. This raises the need for further investigation into the actual mechanical behaviour within the fracture gap of these devices.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fenômenos Biomecânicos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas
15.
Clin Biomech (Bristol, Avon) ; 29(2): 189-95, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24331861

RESUMO

BACKGROUND: Our goal was to determine 3-dimensional interfragmentary motions due to simulated transverse fracture and volar wedge osteotomy of the scaphoid during physiologic flexion-extension of a cadaveric wrist model. METHODS: The model consisted of a cadaveric wrist (n = 8) from the metacarpals through the distal radius and ulna with load applied through the major flexor-extensor tendons. Flexibility tests in flexion-extension were performed in the following 3 test conditions: intact and following transverse fracture and wedge osteotomy of the scaphoid. Scaphoid interfragmentary motions were measured using optoelectronic motion tracking markers. Average peak scaphoid interfragmentary motions due to transverse fracture and wedge osteotomy were statistically compared (P<0.05) to intact. FINDINGS: The accuracy of our computed interfragmentary motions was ± 0.24 mm for translation and ± 0.54° for rotation. Average peak interfragmentary motions due to fracture ranged between 0.9 mm to 1.9 mm for translation and 5.3° to 10.8° for rotation. Significant increases in interfragmentary motions were observed in volar/dorsal translations and flexion/extension due to transverse fracture and in separation and rotations in all 3 motion planes due to wedge osteotomy. INTERPRETATION: Comparison of our results with data from previous in vitro and in vivo biomechanical studies indicates a wide range of peak interfragmentary rotations due to scaphoid fracture, from 4.6° up to 30°, with peak interfragmentary translations on the order of several millimeters. Significant interfragmentary motions, indicating clinical instability, likely occur due to physiologic flexion-extension of the wrist in those with transverse scaphoid fracture with or without volar bone loss.


Assuntos
Fraturas Ósseas/fisiopatologia , Movimento/fisiologia , Osteotomia/métodos , Osso Escafoide/lesões , Fenômenos Biomecânicos , Cadáver , Fraturas Ósseas/cirurgia , Humanos , Instabilidade Articular/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Rotação , Osso Escafoide/cirurgia , Articulação do Punho/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA