Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Endosc Int Open ; 12(9): E1065-E1074, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39285860

RESUMO

The first Asia-Pacific consensus recommendations for endoscopic and interventional management of hilar cholangiocarcinoma were published in 2013. Since then, new evidence on the role of endoscopy for management of malignant hilar biliary obstruction (MHBO) has emerged. To update the recommendation, we reviewed the literature using a PICO (population/intervention/comparison/outcomes) framework and created consensus statements. The expert panel voted anonymously using the modified Delphi method and all final statements were evaluated for the quality of evidence and strength of recommendation. The important points with inadequate supporting evidence were classified as key concepts. There were seven statements and five key concepts that reached consensus. The statements and key concepts dealt with multiple aspects of endoscopy-based management in MHBO starting from diagnosis, strategies and options for biliary drainage, management of recurrent biliary obstruction, management of cholecystitis after biliary stenting, and adjunctive treatment before stenting. Although the recommendations may assist physicians in planning the treatment for MHBO patients, they should not replace the decision of a multidisciplinary team in the management of individual patients.

2.
Endosc Int Open ; 12(9): E1015-E1022, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39263557

RESUMO

Background and study aims The relative procedural performance of needles for endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/B) is unclear. The present study therefore compared six types of 22-gauge FNA/B needles using a bench simulator. Methods Resistance forces during needle puncture and removal, needle tip damage before and after procedure, leakage after puncture of mucinous cyst models, the shape of the puncture surface at the puncture site, amounts of samples extracted, ranges of needle deflection angles, and needle deformation after multiple procedures were compared using six types of needles. Results Maximum resistance forces during puncture and removal were highest for ProCore needles and lowest for Expect needles. None of the needles had damage after puncturing. SharkCore needles showed the highest amount of leakage, whereas FNA needles showed no leakage. The puncture tracts of FNA needles remained in the form of a flap at the puncture site, whereas FNB needles broke off the target material creating a hole. The target material removed was supplemented within the puncture needle. TopGain needles produced significantly larger samples than ProCore, EZShot3 Plus, and Expect needles. FNB needles produced larger and more core samples than FNA needles. EZShot3 Plus needles had the highest range of needle deflection angle using an elevator device and the lowest needle deformation after 20 punctures at full endoscopic angle and a full elevator. Conclusions The performance of the six needles differed in various ways. Understanding the characteristics of each needle may allow for selection of the appropriate needle for each situation.

3.
Endosc Int Open ; 12(8): E955-E961, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39131731

RESUMO

Background and study aims To insert the metal stent delivery system (8.5F) during interventional endoscopic ultrasound (I-EUS), several dilation steps are needed, which may be related to increased bile leakage from a fistula. There have been no definitive studies of dilation force. The aim of the present study was to evaluate dilation force during I-EUS using several dilation devices. Methods In the present study, seven dilation devices were evaluated including bougie dilators such as a straight-shaped dilator (the ES dilator, Soehendra dilator, a standard ERCP catheter) a screw-shaped dilator (Tornus ES, Soehendra stent retriever), and a 4-mm balloon catheter (REN biliary balloon catheter, Hurricane RX). The diameter of each dilator and dilation force were measured. Results Of the bougie dilators, the dilation force of the ES dilator was the highest (0.908±0.035 kg). Of the balloon catheters, the dilation force of the Hurricane RX (3.261±0.024 kg) was slightly higher than that of the REN (3.159±0.072 kg). Of the bougie dilators, although the diameter of the ES dilator was not larger than that of the Tornus ES, the dilation force was stronger. Similarly, the diameter of the Soehendra stent retriever was greater than that of the ERCP catheter or Soehendra dilator and the dilation force was lower. Conclusions Compared with bougie dilators, balloon catheters have stronger dilation force according to our experimental study. The present results should be evaluated in clinical trials.

4.
Endosc Int Open ; 12(8): E962-E967, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39184061

RESUMO

Background and study aims Direct endoscopic necrosectomy (DEN) represents the first-line treatment for walled-off necrosis (WON). However, DEN has a non-negligible rate of overall adverse events (AE) and is time-consuming due to the lack of dedicated devices. This pilot study was designed to evaluate the feasibility and safety of a novel dedicated device for DEN named Necrolit. Patients and methods In this multicenter retrospective analysis,16 patients with WON who underwent DEN using Necrolit were compared with a control group treated with non-dedicated devices. Technical success, AEs, clinical success, number of procedures per patient, procedure time, and length of hospital stay were evaluated. Necrolit technical performance indicators were also studied. Results Technical success was obtained in all patients in both groups. In the Necrolit group, the overall AE rate was 10.1% vs. 15.9% in the control group. Clinical success was 100% in the Necrolit group vs. 81.3% in the control group. Patients treated with Necrolit underwent a slightly lower mean number of procedures (4.1 ± 2.3 vs. 5.1 ± 1.9) with comparable mean procedure time (67.8 ± 39 minutes vs. 70.1 ± 32.6 minutes). Mean duration of hospital stay was 39.4 days (± 30.9) in the Necrolit group vs. 43 days (± 29.4) in the control group. Device-related technical performance was rated positively. Conclusions DEN with Necrolit appears feasible and safe.

5.
Endosc Int Open ; 12(7): E875-E886, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38989254

RESUMO

Background and study aims Endoscopic ultrasound-guided hepaticogastrostomy with bridging between the left and right bile ducts is an alternative to endoscopic transpapillary drainage for malignant hilar biliary obstruction. We aimed to analyze the long-term stent patency of endoscopic ultrasound-guided hepaticogastrostomy with bridging. Patients and methods Patients who underwent endoscopic ultrasound-guided hepaticogastrostomy with bridging between April 2018 and July 2023 were retrospectively analyzed. We retrospectively compared the stent patency of these patients with that of the individuals who underwent endoscopic transpapillary drainage-multi-stenting using unmatched (entire) and propensity score-matched cohorts. Results Endoscopic ultrasound-guided hepaticogastrostomy with bridging had a technical success rate of 90% (18/20). Adverse events were minimal. The number of clinical success cases was 17 and 82 for endoscopic ultrasound-guided hepaticogastrostomy with bridging using metallic stent and endoscopic transpapillary drainage-multi-stenting, respectively. The recurrent biliary obstruction rate was 17.6% and 58.5% for endoscopic ultrasound-guided hepaticogastrostomy with bridging and endoscopic transpapillary drainage-multi-stenting, respectively; the median time to recurrent biliary obstruction (days) was significantly longer for endoscopic ultrasound-guided hepaticogastrostomy with bridging in the entire (not reached vs. 104, P =0.03) and propensity score-matched (183 vs. 79, P =0.05) cohorts. The non-recurrent biliary obstruction rate for endoscopic ultrasound-guided hepaticogastrostomy with bridging was 91.6% at 3 and 6 months and 57% at 12 months. Multivariate analyses revealed that endoscopic ultrasound-guided hepaticogastrostomy with bridging contributed to a lower recurrent biliary obstruction incidence (hazard ratio, 0.31, P =0.05) without significant difference. Conclusions Stent patency was significantly better for endoscopic ultrasound-guided hepaticogastrostomy with bridging. However, future prospective studies are needed.

6.
Endosc Int Open ; 12(6): E740-E749, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38847015

RESUMO

Background and study aims Endoscopic ultrasound (EUS)-guided transmural (TM) deployment of lumen-apposing metal stents (LAMS) is considered relatively safe in non-cirrhotic patients and is cautiously offered to cirrhotic patients. Patients and methods This was a retrospective, multicenter, international matched case-control study to study the safety of EUS-guided TM deployment of LAMS in cirrhotic patients. Results Forty-three cirrhotic patients with model for end-stage liver disease score 12.5 ± 5, with 23 having ascites and 16 with varices underwent EUS-guided TM LAMS deployment, including 19 for pancreatic fluid collection (PFC) drainage, 13 gallbladder drainage, six for endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (ERCP), three for EDGI, one for endoscopic ultrasound-directed transenteric ERCP, and one postsurgical collection drainage. Technical failure occurred in one LAMS for PFC drainage. Clinical failure was encountered in another PFC. Nine adverse events (AEs) occurred. The most common AE was LAMS migration (3), followed by non-bleeding mucosal erosion (2), delayed bleeding (2), sepsis (1), and anesthesia-related complication (pulseless electrical activity) (1). Most AEs were graded as mild (6), followed by severe (2), and moderate (1); the majority were managed conservatively. On univariable comparison, risk of AE was higher when using a 20 × 10 mm LAMS and the absence of through-the-LAMS plastic stent(s). Conditional logistic regression of matched case-control patients did not show any association between potential predicting factors and occurrence of AEs. Conclusions Our study demonstrated that mainly in patients with Child-Pugh scores A and B cirrhosis and despite the presence of mild-to-moderate ascites in over half of cases, the majority of AEs were mild and could be managed conservatively. Further studies are warranted to verify the safety of LAMS in cirrhotic patients.

7.
Endosc Int Open ; 12(6): E715-E722, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38841434

RESUMO

Background and study aims Endoscopic ultrasound-guided pancreatic duct drainage (EUS-PD) is emerging as an effective alternative treatment for obstructive pancreatitis after unsuccessful endoscopic retrograde pancreatography (ERP). However, the high incidence of adverse events associated with EUS-PD (approximately 20%) remains an issue. Recently, we developed a novel plastic stent for EUS-PD, with a radiopaque marker positioned at approximately one-third of the length from the distal end of the stent and side holes positioned exclusively distal to the marker. This study aimed to evaluate the feasibility and safety of using this stent in EUS-PD. Patients and methods We retrospectively reviewed data from 10 patients who underwent EUS-PD with the novel plastic stent at the National Cancer Center Hospital between March 2021 and October 2023. Technical and clinical success, procedure times, adverse events (AEs), recurrent pancreatic duct obstruction (RPO), and time to RPO were assessed. Results Of the 10 patients, five had postoperative benign pancreaticojejunal anastomotic strictures and five had malignant pancreatic duct obstruction. The technical and clinical success rates were both 100% (10/10). An AE (self-limited abdominal pain) occurred in one patient (10.0%). Two patients (20.0%) died of their primary disease during the follow-up period (median, 44 days; range, 25-272 days). The incidence of RPO was 10.0% (1/10), and the 3-month non-RPO rate was 83.3%. Conclusions The novel plastic stent shows potential as a useful and safe tool in EUS-PD.

8.
Endosc Int Open ; 12(5): E684-E685, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38774860
9.
Endosc Int Open ; 12(4): E593-E597, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38654964

RESUMO

Background and study aims External pancreatic fistula in association with disconnected pancreatic duct syndrome is a common sequelae of the percutaneous step-up approach for infected pancreatic necrosis and is associated with significant morbidity. The present study aimed to report the initial outcome of a novel technique of two-scope guided tractogastrostomy for management of this condition. Patients and methods The present study was a retrospective analysis of data from patients with external pancreatic fistula and disconnected pancreatic duct syndrome, who underwent two-scope-guided tractogastrostomy. All the patients had a 24F or larger drain placed in the left retroperitoneum. Transgastric echo endoscopy and sinus tract endoscopy were performed simultaneously to place a stent between the gastric lumen and the sinus tract. Technical success was defined as placement of the stent between the tract and the stomach. Clinical success was defined as successful removal of the percutaneous drain without the occurrence of pancreatic fluid collection, ascites, external fistula, or another intervention 12 weeks after the procedure. Results Three patients underwent two scope-guided tractogastrostomy. Technical and clinical success were achieved in all the patients. No procedure-related side effects or recurrence occurred in any of the patients. Conclusions Two-scope-guided tractogastrostomy for treatment of external pancreatic fistula due to disconnected pancreatic duct syndrome is a feasible technique and can be further evaluated.

10.
Endosc Int Open ; 12(4): E526-E531, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38628391

RESUMO

Background and study aims Endoscopic ultrasound-directed transgastric intervention (EDGI) is a technique that creates an anastomosis between the gastric pouch or jejunum to the excluded stomach in Roux-en-Y gastric bypass (RYGB) anatomy to allow access to the pancreaticobiliary system. Thus far, management of anastomosis closure at the time of lumen-apposing metal stent (LAMS) removal has varied widely. This study aimed to assess the efficacy of primary closure at the time of LAMS removal using a through-the-scope (TTS) tack-based suture system.  Patients and methods This was a two-center retrospective study of RYGB patients who underwent single-stage EDGI using a 20-mm LAMS and subsequent primary anastomosis closure with the X-tack system at the time of stent removal. Patient demographics, procedure details, clinical outcomes, and imaging findings are reported. Results Nineteen patients (median age 63 years, 84% female) underwent single-stage EDGI with a median follow-up of 31.5 months. Adverse events occurred in two patients (11%) who had abdominal pain requiring hospitalization. The median LAMS dwell time was 32 days (range 16-86). All patients (100%) who underwent follow-up studies after LAMS removal had confirmed anastomosis closure (n = 18). Most patients had documented weight loss at the time of LAMS removal and at last follow-up (68%, n = 13). Conclusions Single-stage EDGI is an effective approach to managing RYGB patients with pancreaticobiliary pathology. Thus far, endoscopic TTS tack-based suturing appears to have a high success rate in anastomosis closure after LAMS removal and should be considered as a primary method for preventing chronic fistulae.

11.
Endosc Int Open ; 12(3): E377-E384, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38464978

RESUMO

Background and study aims In cases of inaccessible papilla, EUS-guided biliary drainage (EUS-BD) has been described as an alternative to calibrate benign biliary stenosis. However, few studies are available. Patients and methods This tw-center, retrospective study was designed to evaluate technical success and clinical success at 1 year. All patients who underswent EUS-BD without the rendezvous technique used for calibration of benign biliary stenosis were included from 2016 to 2022. Patients underwent EUS-hepaticogastrostomy (EUS-HGS) during the first session. Then, HGS was used to access the bile duct, allowing calibration of the stenosis: Dilation of the biliary stenosis and placement of double pigtail stents through the stenosis for 1 year. Results Thirty-six patients were included. Technical success was 89% (32/36), with four failures to cross the stenosis but EUS-HGS was performed in 100% of the cases. Nine patients were excluded during calibration because of oncological relapse in six and complex stenosis in three. Three patients had not yet reached 1 year of follow-up. Twenty patients had a calibration for at least 1 year. Clinical success after stent placement was considered in all cases after 1 year of follow-up. Thirteen patients underwent stent removal and no relapse occurred after 435 days of follow-up (SD=568). Global morbidity was 41.7% (15/36) with only one serious complication (needing intensive care), including seven cases of cholangitis due to intrabiliary duct obstruction and five stent migrations. No deaths were reported. Conclusions EUS-BD for calibration in case of benign biliary stenosis is an option. Dedicated materials are needed to decrease morbidity.

12.
Endosc Int Open ; 12(3): E456-E462, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38550768

RESUMO

Background and study aims EUS-guided choledochoduodenostomy (EUS-CDS) is a minimally invasive procedure used to treat malignant biliary obstruction (MBO) by transduodenal placement of a lumen-apposing metal stent (LAMS) into the extrahepatic bile duct. To identify factors that contribute to safe and effective EUS-CDS using LAMS, we performed a systematic review of the literature and meta-analysis. Methods The methodology of our analysis was based on PRISMA recommendations. Electronic databases (Medline, Scopus, EMBASE) were searched up to November 2022. Full articles that included patients with distal malignant biliary obstruction who underwent EUS-CDS using LAMS after failed endoscopic retrograde cholangiopancreatography were eligible. Random-effect meta-analysis was performed reporting pooled rates of technical success, clinical success, and adverse events (AEs) by means of a random model. Multivariate meta-regression and subgroup analysis were performed to assess possible associations between the outcomes and selected variables to assess the correlation between outcomes and different variables. Results were also stratified according to stent size. Results Twelve studies with 845 patients were included in the meta-analysis. Pooled technical and clinical success rates were 96% (95% confidence interval [CI] 94%-98%; I 2 = 52.29%) and 96% (95%CI 95%-98%), respectively, with no significant association with baseline characteristics, such are sex, age, common bile duct diameter, or stent size. The pooled AE rate was 12% (95%CI: 8%-16%; I 2 = 71.62%). The AE rate was significantly lower when using an 8 × 8 mm stent as compared with a 6 × 8 mm LAMS (odds ratio 0.59, 0.35-0.99; P = 0.04), with no evidence of heterogeneity (I 2 = 0%). Conclusions EUS-CDS with LAMS is a safe and effective option for relief of MBO. Selecting an appropriate stent size is crucial for achieving optimal safety outcomes.

13.
Endosc Int Open ; 12(1): E135-E138, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38304353

RESUMO

The central dogma of pain in patients with chronic pancreatitis revolves around the pathophysiology of ductal hypertension owing to stones that obstruct the pancreatic duct. Conventional modalities available to decompress the pancreatic duct are occasionally limited by failed selective pancreatic duct cannulation during endoscopic retrograde cholangiopancreatography. We describe a novel endoscopic approach of EUS-guided laser lithotripsy to assist in pancreatic duct (PD) stone fragmentation in two symptomatic patients with underlying chronic pancreatitis who had failed PD cannulation and extracorporeal shock wave lithotripsy (ESWL). In both cases, a 365-micrometer LightTrail TracTip Holmium laser fiber was advanced within a 19G endoscopic ultrasound aspiration needle (Expect Slimline (SL), Boston Scientific, Marlborough, Massachusetts, United States) under endoscopic ultrasound (EUS) guidance to fragment the PD stones. There were no procedure-related complications encountered and follow-up after 1 month of the procedure revealed significant reduction in abdominal pain scores. To the best of our knowledge, these are the first reported cases of EUS-guided laser lithotripsy performed for PD stones. Our approach of performing laser lithotripsy under EUS guidance obviates the need for an ESWL procedure; however, it is technically more challenging and requires precision to avoid injury to the pancreas. Further prospective studies are required to evaluate the safety and efficacy of this novel approach and its applicability as either a rescue procedure or in tandem with conventional pancreatic endotherapy modalities.

14.
Endosc Int Open ; 12(2): E188-E198, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38348330

RESUMO

Background and study aims Recent advances in endoscopic transmural treatment have improved the clinical outcomes of patients with pancreatic fluid collections (PFCs). However, there is still a debate about the preventive effect of long-term placement of a transmural plastic stent (PS) on recurrence after successful endoscopic ultrasound (EUS)-guided treatment of PFCs. We conducted a systematic review and meta-analysis to evaluate PFC recurrence rates with and without a transmural PS after EUS-guided treatment. Patients and methods A systematic literature search of PubMed, Embase, and the Cochrane database was conducted to identify clinical studies comparing outcomes with and without transmural PS published until September 2022. Data on PFC recurrence and adverse events (AEs) were pooled using a random-effects model. Results Nine studies including 380 patients with long-term transmural PS and 289 patients without PS were identified. The rate of PFC recurrence was significantly lower in patients with transmural PS (pooled odds ratio [OR] = 0.23, 95% confidence interval [CI] [0.08-0.65], P = 0.005). In a subgroup analysis limited to studies focusing on patients with disconnected pancreatic duct syndrome, which has been reported to be a risk factor for PFC recurrence, the OR was numerically lower than that for the entire cohort (OR = 0.14, 95% CI [0.04-0.46]). The rate of AEs was significantly higher with long-term transmural PS (OR = 14.77, 95% CI [4.21-51.83]). Conclusions In this meta-analysis, long-term PS placement reduced the risk of PFC recurrence. Given the potential AEs of indwelling PS, further research is required to evaluate the overall benefits of long-term PS placement.

15.
Endosc Int Open ; 12(2): E181-E187, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38348332

RESUMO

Background and study aims Balloon dilation and plastic stent deployment have been performed as hepaticojejunostomy stricture (HJS) treatment techniques under endoscopic ultrasound guidance (EUS). Although these techniques have shown favorable clinical results, the treatment period can be long because stent deployment is required. In addition, HJS may recur even after treatment because the scar tissue itself remains. To overcome these challenges, we developed an EUS-guided antegrade drill dilation technique for treating HJS. The aim of this study was to evaluate the technical feasibility and safety of this technique in terms of the pre- and post-cholangioscopic findings. Patients and methods This retrospective study included consecutive patients whose conditions were complicated with symptomatic HJS between November 2022 and February 2023. Transluminal antegrade drill dilation (TAD) using a novel drill dilator was attempted within 14 days after EUS-guided hepaticogastrostomy (HGS). HJS was diagnosed with cholangioscopy before TAD, and resolution was evaluated after TAD using cholangioscopy. Results TAD was attempted at approximately 11 days after EUS-HGS. The cholangioscope was inserted successfully in all patients after this procedure. Cholangioscopy revealed stricture without evidence of malignancy in 19 patients. In the remaining three patients, stricture was not observed and these patients underwent stent exchange rather than TAD. Among the 19 patients, passage of the guidewire across the HJS into the intestine was unsuccessful in four patients, and the technical success rate for this procedure was 78.9%. TAD was successful in all 15 patients in whom passage of the guidewire was achieved. Conclusions In conclusion, TAD appears to be technically feasible and safe.

16.
Endosc Int Open ; 12(2): E297-E306, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420151

RESUMO

Background and study aims Besides increasing adequacy, rapid on-site evaluation (ROSE) during endoscopic ultrasound (EUS) or endoscopic retrograde cholangiopancreatography (ERCP) may impact choices and timing of subsequent therapeutic procedures, yet has been unexplored. Patients and methods This was a retrospective evaluation of a prospectively maintained database of a tertiary, academic centre with availability of ROSE and hybrid EUS-ERCP suites. All consecutive patients referred for pathological confirmation of suspected malignancy and jaundice or gastric outlet obstruction (GOO) between Jan-2020 and Sep-2022 were included. Results Of 541 patients with underlying malignancy, 323 (59.7%) required same-session pathological diagnosis (male: 54.8%; age 70 [interquartile range 63-78]; pancreatic cancer: 76.8%, biliary tract adenocarcinoma 16.1%). ROSE adequacy was 96.6%, higher for EUS versus ERCP. Among 302 patients with jaundice, ERCP-guided stenting was successful in 83.1%, but final drainage was completed in 97.4% thanks to 43 EUS-guided biliary drainage procedures. Twenty-one patients with GOO were treated with 15 EUS-gastroenterostomies and six duodenal stents. All 58 therapeutic EUS procedures occurred after adequate ROSE. With ERCP-guided placement of stents, the use of plastic stents was significantly higher among patients with inadequate ROSE (10/11; 90.9%) versus adequate sampling (14/240; 5.8%) P <0.0001; OR 161; 95%CI 19-1352). Median hospital stay for diagnosis and palliation was 3 days (range, 2-7) and median time to chemotherapy was 33 days (range, 24-47). Conclusions Nearly two-thirds of oncological candidates for endoscopic palliation require contemporary pathological diagnosis. ROSE adequacy allows, since the index procedure, state-of-the-art therapeutics standardly restricted to pathologically confirmed malignancies (e.g. uncovered SEMS or therapeutic EUS), potentially reducing hospitalization and time to oncological treatments.

17.
Endosc Int Open ; 12(2): E317-E323, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420155

RESUMO

Background and study aims Optimal timing for removal of lumen-apposing metal stents (LAMS) for effective drainage of pancreatic fluid collections (PFC) while minimizing adverse events (AE) is unknown. Outcomes of early (≤ 4 weeks) or delayed (> 4 weeks) LAMS removal on both clinical efficacy and the incidence of AE were assessed. Patients and methods This was a retrospective analysis of a prospectively maintained registry of PFC drainage between November 2016 and September 2021. Clinical success was defined as a 75% decrease in fluid collection volume with no need for reintervention at 6 months. AE were defined using the American Society for Gastrointestinal Endoscopy lexicon. Multiple logistic regression analysis was performed to determine variables associated with clinical success and AE. Results A total of 108 consecutive PFCs were included. LAMS deployment was technically successful in 103 of 108 cases (95.4%). Failure was associated with collection diameter ≤ 4 cm (odds ratio [OR] 24.0, P = 0.005) and presence of more than 50% necrotic material (OR 20.1, P = 0.01). Stents were left in place for a median of 48 days. Patients with early stent removal (< 4 weeks) had clinical success in 70.0% of cases, which was significantly less than in the group with delayed stent removal (96.4%, P = 0.03). On multiple regression analysis, clinical failure was associated with early stent removal (OR 25.5, P = 0.003). AEs occurred in 8.7% of cases (9/103). There were no predictors of AE. Notably, delayed stent removal did not predict the occurrence of AE. Conclusions Early LAMS removal (< 4 weeks) did not prevent AEs but did lead to increased clinical failure.

18.
Endosc Int Open ; 12(2): E291-E296, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420158

RESUMO

Background and study aims Favorable outcomes were noted with refinement in newer endoscopic ultrasound-guided liver biopsy (EUS-LB) needle tips. Still, the overall usefulness and benefit are yet to be well explored. Patients and methods This was a retrospective analysis of patients with EUS-LB (Franseen-tip 19G versus 22G FNB needle) over 2 years. EUS-LB was obtained in a one-pass, two-actuation, modified wet suction technique. Diagnostic yield, fragmentation rate, aggregate specimen length (AL), number of complete portal tracts (CPT), length of longest intact core (LIC), adverse events (AEs) (early), and cost of the procedure (1USD = 82 INR) were compared. Results Fifty-four patients (33 [61.1%], female) successfully underwent EUS-LB with a median age of 46 years (interquartile range [IQR] 34-54); the majority 32 (59.2%) underwent 19G biopsies. There was a significantly increased median (IQR) AL in the 19G compared with 22G (20 mm [19-21] vs. 15 [14-15], P < 0.001), respectively. Similarly, significantly lengthier median LIC and CPT were seen, respectively. A nonsignificant diagnostic yield was noted (100% vs. 90.9%, P = 0.082), respectively. The fragmentation rate was higher in 22G FNB needles (36.4% [95% CI 16-56] vs. 12.5% [95% CI 1-24], respectively; P = 0.038). Seven patients (12.9%) had mild AEs with no difference between groups. The average procedure cost with 19G was INR 63000 (768$), and with 22G needle was INR 54500 (664$). Conclusions The Franseen-tip 19G outperforms 22G with a significantly lower fragmentation rate, longer AL, LIC, and a higher number of CPT with a marginal increase in the procedure cost, without any difference in diagnostic yield and safety.

19.
Endosc Int Open ; 12(2): E262-E268, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420156

RESUMO

Background and study aims Biloma is treated endoscopically with endoscopic retrograde cholangiography (ERCP) or endoscopi ultrasound-guided transluminal biloma drainage (EUS-TBD). However, almost all previous studies have used both internal and external drainage. External drainage has the disadvantages of poor cosmetic appearance and self-tube removal. The aim of the present study was to evaluate the internal endoscopic drainage for complex biloma after hepatobiliary surgery with an ERCP- or EUS-guided approach, without external drainage. Patients and methods This retrospective study included consecutive patients who had bilomas. A 7F plastic stent was deployed from the biloma to the duodenum in the ERCP group and the metal stent was deployed from the biloma to the stomach in the EUS-TBD group. Results Forty-seven patients were enrolled. The technical success rate was similar between the groups (ERCP 94% vs EUS-TBD 100%, P =0.371); however, mean procedure time was significantly shorter in the EUS-TBD group (16.9 minutes) than in the ERCP group (26.6 minutes) ( P =0.009). The clinical success rate was 87% (25 of 32 patients) in the ERCP group and 84% (11 of 13 patients) in the EUS-TBD group ( P =0.482). The duration of median hospital stay was significantly shorter in the EUS-TBD group (22 days) than in the ERCP group (46 days) ( P =0.038). There was no significant difference in procedure-associated adverse events between the groups. Conclusions In conclusion, ERCP and EUS-TBD are complementary techniques, each with its own merits in specific clinical scenarios. If both techniques can be performed, EUS-TBD should be considered because of the short times for the procedure, hospital stay. and biloma resolution.

20.
Endosc Int Open ; 12(1): E108-E115, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38250165

RESUMO

Background and study aims Percutaneous transhepatic biliary drainage (PTBD) is the traditional second-line option after unsuccessful endoscopic retrograde cholangiopancreatography (ERCP). Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HG) is a viable alternative to PTBD. Our study aimed to compare outcomes of EUS-HG and PTBD for benign and malignant biliary diseases following failed ERCP. Patients and methods This single-center study retrospectively analyzed patients undergoing EUS-HG and PTBD for benign and malignant biliary disorders. A propensity score-matched analysis was performed using age, sex, and Charlson Comorbidity Index. The primary outcome was clinical success, which we defined as a decrease in total bilirubin by ≥ 50% at 2 weeks for malignant disease and resolution of the biliary disorder for benign disease. Results In total, 41 patients underwent EUS-HG and 138 patients underwent PTBD. After propensity score matching in a 1:2 ratio, 32 EUS-HG patients were matched with 64 PTBD. Technical success was achieved in 29 of 32 (91%) for EUS-HG and 63 of 64 (98%) for PTBD ( P =0.11). Clinical success was 100% for EUS-HG and 75% for PTBD ( P =0.0021). EUS-HG was associated with a lower adverse event rate (EUS-HG 13% vs. PTBD 58%, P <0.0001), shorter procedure duration (median 60 vs. 115 minutes, P <0.0001), shorter post-procedure length of stay (median 2 vs. 4 days, P <0.0001), and fewer reinterventions (median 1 vs. 3, P <0.0001). Conclusions Our results suggest that EUS-HG is superior to PTBD in the treatment of benign and malignant biliary disorders after failed ERCP.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA