1.
J Surg Oncol ; 130(3): 516-522, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39099202

RESUMO

BACKGROUND: Thermal ablation has recently become a key therapy for the treatment of colorectal liver metastasis (CLM). However, the role of ablation in combination with resection has not yet been firmly established. We hypothesize that in patients with CLM, those who undergo liver resection with ablation (RA) have similar outcomes compared with those who undergo liver resection only. METHODS: We reviewed a multicenter international database of 906 surgical procedures for CLM from 5 high volume hepatobiliary surgical units. Patients undergoing RA (n = 63) were matched based on the number of lesions and tumor size using a 1:1 balanced propensity score analysis with those having resection only (n = 63). Our primary outcomes were overall survival (OS) and disease-free survival (DFS). RESULTS: The mean age of our cohort was 58 ± 11 years, with 43% females. With a median follow-up of 70.8 months, patients in the resection and RA group had a median OS of 45.1 and 54.8 months (p = 0.71), respectively. The median DFS was 22.7 and 14.2 months (p = 0.045), respectively. Using a multivariate Cox proportional hazards regression model, the treatment approach was not associated with OS (p = 0.94) or DFS (p = 0.059). A higher number of lesions is independently associated with worse DFS (hazard ratio: 1.12, p < 0.01). When there was disease recurrence, the region of recurrence was similar between the RA versus resection only groups (p = 0.27), but there was a shorter time to recurrence in the RA group (p = 0.002). CONCLUSION: For CLM, the treatment approach was not significantly associated with OS or DFS, while tumor biology likely played an important role. Prospective research on the quality and effectiveness of thermal ablation combined with hepatic resection is warranted.


Assuntos
Neoplasias Colorretais , Hepatectomia , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/mortalidade , Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/mortalidade , Feminino , Masculino , Hepatectomia/mortalidade , Hepatectomia/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Ablação por Cateter/mortalidade , Ablação por Cateter/métodos , Taxa de Sobrevida , Idoso , Seguimentos , Terapia Combinada
2.
Ann Surg Open ; 5(2): e406, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38911657

RESUMO

Objective: The aim of this systematic review and meta-analysis is to identify current robotic assistance systems for percutaneous liver ablations, compare approaches, and determine how to achieve standardization of procedural concepts for optimized ablation outcomes. Background: Image-guided surgical approaches are increasingly common. Assistance by navigation and robotic systems allows to optimize procedural accuracy, with the aim to consistently obtain adequate ablation volumes. Methods: Several databases (PubMed/MEDLINE, ProQuest, Science Direct, Research Rabbit, and IEEE Xplore) were systematically searched for robotic preclinical and clinical percutaneous liver ablation studies, and relevant original manuscripts were included according to the Preferred Reporting items for Systematic Reviews and Meta-Analyses guidelines. The endpoints were the type of device, insertion technique (freehand or robotic), planning, execution, and confirmation of the procedure. A meta-analysis was performed, including comparative studies of freehand and robotic techniques in terms of radiation dose, accuracy, and Euclidean error. Results: The inclusion criteria were met by 33/755 studies. There were 24 robotic devices reported for percutaneous liver surgery. The most used were the MAXIO robot (8/33; 24.2%), Zerobot, and AcuBot (each 2/33, 6.1%). The most common tracking system was optical (25/33, 75.8%). In the meta-analysis, the robotic approach was superior to the freehand technique in terms of individual radiation (0.5582, 95% confidence interval [CI] = 0.0167-1.0996, dose-length product range 79-2216 mGy.cm), accuracy (0.6260, 95% CI = 0.1423-1.1097), and Euclidean error (0.8189, 95% CI = -0.1020 to 1.7399). Conclusions: Robotic assistance in percutaneous ablation for liver tumors achieves superior results and reduces errors compared with manual applicator insertion. Standardization of concepts and reporting is necessary and suggested to facilitate the comparison of the different parameters used to measure liver ablation results. The increasing use of image-guided surgery has encouraged robotic assistance for percutaneous liver ablations. This systematic review analyzed 33 studies and identified 24 robotic devices, with optical tracking prevailing. The meta-analysis favored robotic assessment, showing increased accuracy and reduced errors compared with freehand technique, emphasizing the need for conceptual standardization.

3.
Cancers (Basel) ; 16(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38539527

RESUMO

With the rapidly evolving field of image-guided tumor ablation, there is an increasing demand and need for tools to optimize treatment success. Known factors affecting the success of (non-)thermal liver ablation procedures are the ability to optimize tumor and surrounding critical structure visualization, ablation applicator targeting, and ablation zone confirmation. A recent study showed superior local tumor progression-free survival and local control outcomes when using transcatheter computed tomography hepatic angiography (CTHA) guidance in percutaneous liver ablation procedures. This pictorial review provides eight clinical cases from three institutions, MD Anderson (Houston, TX, USA), Gustave Roussy (Paris, France), and Amsterdam UMC (Amsterdam, The Netherlands), with the intent to demonstrate the added value of real-time CTHA guided tumor ablation for primary liver tumors and liver-only metastatic disease. The clinical illustrations highlight the ability to improve the detectability of the initial target liver tumor(s) and identify surrounding critical vascular structures, detect 'vanished' and/or additional tumors intraprocedurally, differentiate local tumor progression from non-enhancing scar tissue, and promptly detect and respond to iatrogenic hemorrhagic events. Although at the cost of adding a minor but safe intervention, CTHA-guided liver tumor ablation minimizes complications of the actual ablation procedure, reduces the number of repeat ablations, and improves the oncological outcome of patients with liver malignancies. Therefore, we recommend adopting CTHA as a potential quality-improving guiding method within the (inter)national standards of practice.

4.
Cancers (Basel) ; 15(15)2023 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-37568777

RESUMO

BACKGROUND: HIFU ablation of liver malignancies is particularly challenging due to respiratory motion, high tissue perfusion and the presence of the rib cage. Based on our previous development of a super-convergent phased-array transducer, we aimed to further investigate, in vivo, its applicability to deep intrahepatic targets. METHODS: In a series of six pigs, a pseudo-tumor model was used as target, visible both on intra-operatory MRI and post-mortem gross pathology. The transcostal MRgHIFU ablation was prescribed coplanar with the pseudo-tumor, either axial or sagittal, but deliberately shifted 7 to 18 mm to the side. No specific means of protection of the ribs were implemented. Post-treatment MRI follow-up was performed at D7, followed by animal necropsy and gross pathology of the liver. RESULTS: The pseudo-tumor was clearly identified on T1w MR imaging and subsequently allowed the MRgHIFU planning. The peak temperature at the focal point ranged from 58-87 °C. Gross pathology confirmed the presence of the pseudo-tumor and the well-delineated MRgHIFU ablation at the expected locations. CONCLUSIONS: The specific design of the transducer enabled a reliable workflow. It demonstrated a good safety profile for in vivo transcostal MRgHIFU ablation of deep-liver targets, graded as challenging for standard surgery.

5.
Eur J Radiol ; 163: 110803, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37004464

RESUMO

OBJECTIVES: Colorectal cancers (CRC) are among the world's most prevailing cancer entities. In a third of all cases, the patients have already developed distant metastases - mainly in the liver - at the time of detection. Colorectal liver metastases (CRLM) can be treated by surgical resection or, as is possible in most cases, by percutaneous ablation. For selecting the liver metastases eligible for radiofrequency ablation (RFA) or microwave ablation (MWA), the common imaging modalities are magnetic resonance imaging (MRI), positron emission tomography/computed tomography (PET/CT), and contrast-enhanced computed tomography (CE-CT). This study aims to evaluate those imaging modalities for selecting liver lesions eligible for ablation according to their long-term cost-effectiveness. MATERIALS AND METHODS: A Markov model was applied, calculating quality-adjusted life years (QALYs) and accumulative costs for every diagnostic strategy, according to predefined input parameters obtained from published research. Further, sensitivity analyses were executed to prove the certainty of the calculations by running Monte-Carlo simulations with 30,000 reiterations. The Willingness-to-pay (WTP) is at $ 100,000. All calculations are based on the U.S. healthcare system. RESULTS: CE-CT caused cumulative costs of $ 31,940.98 and 8,99 QALYs, whereas MRI caused $ 32,070.83 and 9,01 QALYs. PET/CT caused cumulative costs of $ 33,013.21 and 8,99 QALYs. CONCLUSION: In conclusion, according to our analysis, MRI is the most cost-effective strategy for detecting liver metastases eligible for ablation and therefore should be seen as the gold standard.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Análise Custo-Benefício , Análise de Custo-Efetividade , Tomografia Computadorizada por Raios X/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Tomografia por Emissão de Pósitrons/métodos
6.
Acta Radiol ; 64(1): 5-12, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34918955

RESUMO

BACKGROUND: Patients with colorectal liver metastases (CRLM) who undergo thermal ablation are at risk of developing new CRLM after ablation. Identification of these patients might enable individualized treatment. PURPOSE: To investigate whether an existing machine-learning model with radiomics features based on pre-ablation computed tomography (CT) images of patients with colorectal cancer can predict development of new CRLM. MATERIAL AND METHODS: In total, 94 patients with CRLM who were treated with thermal ablation were analyzed. Radiomics features were extracted from the healthy liver parenchyma of CT images in the portal venous phase, before thermal ablation. First, a previously developed radiomics model (Original model) was applied to the entire cohort to predict new CRLM after 6 and 24 months of follow-up. Next, new machine-learning models were developed (Radiomics, Clinical, and Combined), based on radiomics features, clinical features, or a combination of both. RESULTS: The external validation of the Original model reached an area under the curve (AUC) of 0.57 (95% confidence interval [CI]=0.56-0.58) and 0.52 (95% CI=0.51-0.53) for 6 and 24 months of follow-up. The new predictive radiomics models yielded a higher performance at 6 months compared to 24 months. For the prediction of CRLM at 6 months, the Combined model had slightly better performance (AUC=0.60; 95% CI=0.59-0.61) compared to the Radiomics and Clinical models (AUC=0.55-0.57), while all three models had a low performance for the prediction at 24 months (AUC=0.52-0.53). CONCLUSION: Both the Original and newly developed radiomics models were unable to predict new CLRM based on healthy liver parenchyma in patients who will undergo ablation for CRLM.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Neoplasias Colorretais/diagnóstico por imagem
7.
Semin Intervent Radiol ; 40(6): 536-543, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38274223

RESUMO

The surgical management of primary and secondary liver tumors is constantly evolving. Patient selection, particularly with regard to determining resectability, is vital to the success of programs directed toward invasive treatments of liver tumors. Particular attention should be paid toward determining whether patients are best served with surgical resection or ablative therapies. A multidisciplinary approach is necessary to provide optimal care to patients with liver malignancy.

8.
J Pers Med ; 13(1)2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36675694

RESUMO

Colorectal cancer (CRC) is the third most common tumor worldwide and it is characterized in 20-30% of cases by liver involvement, which strongly affects the long-term patient outcome. There are many available therapies for liver colorectal metastases (CRLMs); the current standard of care is represented by liver resection, and when feasible, associated with systemic chemotherapy. Microwave thermal ablation (MWA) is a viable option in unresectable patients or to achieve treatment with a parenchymal spearing approach. A literature review was performed for studies published between January 2000 and July 2022 through a database search using PUBMED/Medline and the Cochrane Collaboration Library with the following MeSH search terms and keywords: microwave, ablation, liver metastases, colorectal neoplasm, and colon liver rectal metastases. The recurrence rate and overall patients' survival were evaluated, showing that laparoscopic MWA is safe and effective to treat CRLMs when resection is not feasible, or a major hepatectomy in fragile patients is necessary. Considering the low morbidity of this procedure, it is a viable option to treat patients with recurrent diseases in the era of effective chemotherapy and multimodal treatments.

9.
BMC Cardiovasc Disord ; 21(1): 581, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34876030

RESUMO

BACKGROUND: High-Frequency Irreversible Electroporation (H-FIRE) is a novel technology for non-thermal ablation. Different from Irreversible electroporation (IRE), H-FIRE delivers bipolar electrical pulses without muscle contraction and does not cause electrolysis. Currently, little is known regarding the cardiac safety during the administration of H-FIRE on liver. The aim of this study was to evaluate the changes of electrocardiogram (ECG) and biomarkers of cardiac damage during asymmetrical waveform of H-FIRE therapy in vivo. METHODS: The swines (n = 7) in IRE group, which used 100 pulses (2200 V, 100-100 µs configuration), were administrated with muscle relaxant under anesthesia. In the absence of muscle relaxant, 7 swines in H-FIRE group were performed with 2400 pulses (3000 V, 5-3-3-5 µs configuration). Midazolam (0.5 mg/kg) and xylazine hydrochloride (20 mg/kg) were given to induce sedation, followed by Isoflurane (2.5%, 100% oxygen, 3 L/min) to maintain sedation in all the swines. Limb lead ECG recordings were analyzed by two electrophysiologists to judge the arrhythmia. Cardiac and liver tissue was examined by pathology technique. RESULTS: The ablation zones were larger in H-FIRE than IRE. Both IRE and H-FIRE did not affect the autonomous cardiac rhythm. Even when the electrical signal of IRE and H-FIRE fell on ventricular vulnerable period. Moreover, cTnI in IRE group showed an increase in 4 h after ablation, and decreased to baseline 72 h after ablation. However, cTnI showed no significant change during the administration of H-FIRE. CONCLUSIONS: The study suggests an asymmetrical waveform for H-FIRE is a promising measure for liver ablation. The results were based on normal liver and the swines without potential cardiac diseases. With the limitations of these facts, asymmetrical waveform for H-FIRE of liver tissue seems relatively safe without major cardiac complications. The safety of asymmetrical waveform for H-FIRE needs to evaluate in future.


Assuntos
Técnicas de Ablação/efeitos adversos , Arritmias Cardíacas/etiologia , Eletroporação , Traumatismos Cardíacos/etiologia , Fígado/cirurgia , Potenciais de Ação , Animais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia , Feminino , Traumatismos Cardíacos/patologia , Frequência Cardíaca , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Miocárdio/patologia , Suínos , Porco Miniatura , Fatores de Tempo
10.
Oncology ; 99(11): 722-731, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34515198

RESUMO

Interventional oncology plays a major role within modern oncological patient management. Image-guided thermal ablation has been recognized as a successful local therapeutic option in patients with primary and secondary malignant liver diseases, as also recalled by the recent European Society of Medical Oncology (ESMO) guidelines on colorectal metastases. As image-guided treatments may be as effective as surgery in selected patients with liver lesions, the clinical oncologist should be familiar with the indications, risks, and technical aspects of liver ablation in order to provide their patients with the best outcomes. This article provides a broad overview of the most commonly used ablation techniques and highlights the most relevant technical aspects such as the ideal setting in the operating theatre; which image-guided methods are available, including the growing application of fusion imaging; or contrast-enhanced ultrasound for guiding/monitoring the procedure. A further aim is to expand the knowledge among medical oncologists about liver ablation procedures and to provide insights into the future perspectives of percutaneous minimally invasive procedures in the liver.


Assuntos
Criocirurgia/métodos , Eletroporação/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Hipertermia Induzida/métodos , Neoplasias Hepáticas/cirurgia , Oncologistas , Ablação por Radiofrequência/métodos , Cirurgia Assistida por Computador/métodos , Terapia Combinada/métodos , Humanos , Oncologia Cirúrgica/métodos , Resultado do Tratamento
11.
Med Phys ; 48(10): 6226-6236, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34342018

RESUMO

PURPOSE: Colorectal cancer is the third most common form of cancer in the United States, and up to 60% of these patients develop liver metastasis. While hepatic resection is the curative treatment of choice, only 20% of patients are candidates at the time of diagnosis. While percutaneous thermal ablation (PTA) has demonstrated 24%-51% overall 5-year survival rates, assurance of sufficient ablation margin delivery (5 mm) can be challenging, with current methods of 2D distance measurement not ensuring 3D minimum margin. We hypothesized that biomechanical model-based deformable image registration (DIR) can reduce spatial uncertainties and differentiate local tumor progression (LTP) patients from LTP-free patients. METHODS: We retrospectively acquired 30 patients (16 LTP and 14 LTP-free) at our institution who had undergone PTA and had a contrast-enhanced pre-treatment and post-ablation CT scan. Liver, disease, and ablation zone were manually segmented. Biomechanical model-based DIR between the pre-treatment and post-ablation CT mapped the gross tumor volume onto the ablation zone and measured 3D minimum delivered margin (MDM). An in-house cone-tracing algorithm determined if progression qualitatively collocated with insufficient 5 mm margin achieved. RESULTS: Mann-Whitney U test showed a significant difference (p < 0.01) in MDM from the LTP and LTP-free groups. A total of 93% (13/14) of patients with LTP had a correlation between progression and missing 5 mm of margin volume. CONCLUSIONS: Biomechanical DIR is able to reduce spatial uncertainty and allow measurement of delivered 3D MDM. This minimum margin can help ensure sufficient ablation delivery, and our workflow can provide valuable information in a clinically useful timeframe.


Assuntos
Ablação por Cateter , Neoplasias Colorretais , Neoplasias Hepáticas , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/cirurgia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
12.
Int J Hyperthermia ; 38(1): 1140-1148, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34353206

RESUMO

PURPOSE: Microwave ablation (MWA) provides an effective treatment of lung and liver tumors but suffers from a lack of reproducibility of ablation size among currently available technologies. In-vitro evaluations are far removed from clinical practices because of uninfused tissue. This study is in-vivo preclinical testing of a new MWA system on swine lungs and liver. MATERIALS AND METHODS: All ablations were performed under CT guidance and multiple algorithms were tested with a power of 50, 75, and 100 W for durations of 3, 5, 8, 10, and 15 min. A 3 D-evaluation of the ablation zone was carried out using enhanced-CT. The sphericity index, coefficients of variation, and energy efficiency (which corresponds to the volume yield according to the power supplied) were calculated. RESULTS: Fifty liver and 48 lung ablations were performed in 17 swine. The sphericity index varies from 0.50 to 0.80 for liver ablations and from 0.40 to 0.69 for lung ablations. The coefficient of variation was below 15% for 4/5 and 4/8 protocols for lung and liver ablations, respectively. The energy efficiency seems to decrease with the duration of the ablation from 0.60 × 10-3 cm3/J (75 W, 3 min) to 0.26 × 10-3 cm3/J (100 W, 15 min) in the liver and from 0.57 × 10-3 cm3/J (50 W, 10 min) to 0.42 × 10-3 cm3/J (100 W, 12 min) in the lungs. CONCLUSION: A shorter treatment time provides the best energy efficiency, and the best reproducibility is obtained for a 10 min treatment duration. The system tested provides an interesting reproducibility in both lung and liver measurements. Our results may help interventional radiologists in the optimal selection of treatment parameters.


Assuntos
Técnicas de Ablação , Ablação por Cateter , Animais , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Micro-Ondas , Reprodutibilidade dos Testes , Suínos , Tomografia Computadorizada por Raios X
13.
Front Microbiol ; 12: 649091, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34276585

RESUMO

Nanosecond pulsed electric field (nsPEF) is a novel ablation technique that is based on high-intensity electric voltage to achieve tumour-killing effect in the target region, and increasingly considered for treating tumours of the liver, kidneys and other organs with rich blood supply. This study aims to observe effect of nsPFE treatment on serum metabolites and gut microbiota. The serum and faecal specimens of the pigs were collected pre- and post-treatment. The gut microbiota of pigs was sequenced by Illumina Miseq platform for analysing the diversity and alterations of gut microbiota. Liquid chromatography-mass spectrometry (LC-MS)-based metabonomic analysis and Pearson coefficient method were also used to construct the interaction system of different metabolites, metabolic pathways and flora. A total of 1,477 differential metabolites from the serum were identified by four cross-comparisons of different post-operative groups with the control group. In addition, an average of 636 OTUs per sample was detected. Correlation analysis also revealed the strong correlation between intestinal bacteria and differential metabolites. The nsPEF ablation of the liver results in a degree of liver damage that affects various metabolic pathways, mainly lipid metabolism, as well as gut microbiota. In conclusion, our study provided a good point for the safety and feasibility of applying nsPEF on liver through the integrated analysis of metabolomics and microbiomes, which is beneficial for the improvement of nsPEF in clinical use.

14.
Int J Hyperthermia ; 38(1): 823-829, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34058947

RESUMO

BACKGROUND: Microwaves (MWs) deliver relatively high temperatures into biological tissue and cover a large ablation zone. This study aims to evaluate the efficacy and effectiveness of water-cooled double-needle MW ablation arrays in assisting the hepatic transection of an in vivo pig model. METHODS: Our research program comprised computer modeling, tissue-mimicking phantom experiments, and in vivo pig liver experiments. Computer modeling was based on the finite element method (FEM) to evaluate ablation temperature distributions. In tissue-mimicking phantom and in vivo pig liver ablation experiments, the performances of the water-cooled MW ablation array and conventional clamp crushing liver resection were compared. RESULTS: FEM showed that the maximum lateral ablation diameter at 100 W output and a duration of 60 s was 3 cm (assessed at 50 °C isotherm). In the phantom, the maximum transverse ablation diameter of the double-needle MW ablation increased rapidly to 3 cm in 60 s at 50 W. The blood loss and blood loss per transection area in Group A were significantly lower than those in Group B (18 (7-26) ml vs. 34 (19-57) ml, and 2.4 (2-3.1) ml/cm2 vs. 6.9 (3.2-8.3) ml/cm2, respectively) (p < 0.05). The transection speed in Group A (2.6(1.9-3.8) cm2/min) was significantly faster than that in Group B (1.7(1.1-2.2) cm2/min) (p < 0.05). CONCLUSION: In this experimental model, the new water-cooled MW array-assisted liver resection (LR) has the potential advantage of less blood loss and rapid removal than the conventional LR.


Assuntos
Ablação por Cateter , Micro-Ondas , Animais , Hepatectomia , Fígado/diagnóstico por imagem , Fígado/cirurgia , Suínos , Água
15.
Acta Anaesthesiol Scand ; 65(9): 1248-1253, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34028010

RESUMO

BACKGROUND: High-frequency jet ventilation is necessary to reduce organ movements during stereotactic liver ablation. However, post-operative hypertensive episodes especially following irreversible electroporation ablation compared with microwave ablation initiated this study. The hypothesis was that hypertensive episodes could be related to ventilation or ablation method. METHODS: The aim of this retrospective study was to assess the proportion of patients with hypertensive events during recovery following liver ablation under general anaesthesia and to analyse the relation to ventilation and ablation technique. A medical chart review of 134 patients undergoing either high-frequency jet ventilation and microwave ablation (n = 45), high-frequency jet ventilation and irreversible electroporation (n = 44), or conventional ventilation and microwave ablation (n = 45) was performed. The proportion of patients with at least one episode of systolic arterial pressure 140-160, 160-180 or >180 mmHg during early recovery and the impact of ventilation method was studied. RESULTS: Out of 134 patients, 100, 75 and 34 patients had at least one episode of mild, moderate and severe hypertension. Microwave ablation, as well as high frequency jet ventilation, was associated with an increased odds ratio for post-operative hypertension. The proportion of patients with at least one severe hypertensive event was 18/45, 9/44 and 7/45, respectively. CONCLUSION: Both ventilation and ablation technique had an impact on post-operative hypertensive episodes. The microwave ablation/high-frequency jet ventilation combination increased the risk as compared with irreversible electroporation/high-frequency jet ventilation and microwave ablation/conventional ventilation.


Assuntos
Ventilação em Jatos de Alta Frequência , Hipertensão , Neoplasias Hepáticas , Humanos , Hipertensão/epidemiologia , Neoplasias Hepáticas/cirurgia , Estudos Retrospectivos
16.
Front Surg ; 8: 626297, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33816545

RESUMO

Background: Liver resection represents the first curative treatment to treat primary and secondary hepatic tumors. Thoracoscopic liver ablation is a viable and minimally invasive alternative treatment, especially for patients with previous multiple abdominal surgeries. The aim of the study was to evaluate the safety and efficacy of thoracoscopic ablation for liver tumors. Methods: Retrospective analysis of a prospective database of patients with liver tumors, treated with thoracoscopic trans-diagrammatic ablation (MWA or RFA) at our institution from 2012 to 2018. The primary endpoint was post-operative mortality at 30 days, while secondary endpoints were morbidity and efficacy of ablation (i.e., response rate evaluated according to mRECIST criteria, and overall patient survival). Patient demographics, operational characteristics, and complications were recorded. Results: A total of 13 nodules were treated in 10 patients with a median age of 65.5 years. Post-operative mortality was 0%, and overall morbidity was 40% (Clavien-Dindo I complications 30%, II 0%, III 10%, IV 0%). Complete radiological response was obtained in 83.3% of nodules at 3 months. After a median follow-up of 20.95 months, the local tumor progression rate was 30%, with an intra-segmental-recurrence of 30%, and an intra-hepatic-recurrence of 30%. The overall 1-, 2-, and 3-years survival rates were 80%, 58%, and 58%. Conclusion: Thoracoscopic trans-diaphragmatic ablation proved to be a safe and effective way to treat liver tumors when abdominal approach is not feasible. Considering the low morbidity, it is a viable option to treat patients with recurrent disease and/or previous multiple abdominal surgeries.

17.
Magn Reson Imaging ; 80: 90-97, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33901585

RESUMO

PURPOSE: Hepatic thermal ablation therapy can result in c-Met-mediated off-target stimulation of distal tumor growth. The purpose of this study was to determine if a similar effect on tumor metabolism could be detected in vivo with hyperpolarized 13C MRI. MATERIALS AND METHODS: In this prospective study, female Fisher rats (n = 28, 120-150 g) were implanted with R3230 rat breast adenocarcinoma cells and assigned to either: sham surgery, hepatic radiofrequency ablation (RFA), or hepatic RFA + adjuvant c-Met inhibition with PHA-665752 (RFA + PHA). PHA-665752 was administered at 0.83 mg/kg at 24 h post-RFA. Tumor growth was measured daily. MRI was performed 24 h before and 72 h after treatment on 14 rats, and the conversion of 13C-pyruvate into 13C-lactate within each tumor was quantified as lactate:pyruvate ratio (LPR). Comparisons of tumor growth and LPR were performed using paired and unpaired t-tests. RESULTS: Hepatic RFA alone resulted in increased growth of the distant tumor compared to sham treatment (0.50 ± 0.13 mm/day versus 0.11 ± 0.07 mm/day; p < 0.001), whereas RFA + PHA (0.06 ± 0.13 mm/day) resulted in no significant change from sham treatment (p = 0.28). A significant increase in LPR was seen following hepatic RFA (+0.016 ± 0.010, p = 0.02), while LPR was unchanged for sham treatment (-0.048 ± 0.051, p = 0.10) or RFA + PHA (0.003 ± 0.041, p = 0.90). CONCLUSION: In vivo hyperpolarized 13C MRI can detect hepatic RFA-induced increase in lactate flux within a distant R3230 tumor, which correlates with increased tumor growth. Adjuvant inhibition of c-Met suppresses these off-target effects, supporting a role for the HGF/c-Met signaling axis in these tumorigenic responses.


Assuntos
Ablação por Cateter , Neoplasias Hepáticas , Neoplasias , Animais , Feminino , Fígado/diagnóstico por imagem , Fígado/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Prospectivos , Ratos
18.
Diagnostics (Basel) ; 11(2)2021 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-33672993

RESUMO

Approximately 50% of colorectal cancer patients will develop metastases during the course of the disease. Local or locoregional therapies for the treatment of liver metastases are used in the management of oligometastatic colorectal liver disease, especially in nonsurgical candidates. Thermal ablation (TA) is recommended in the treatment of limited liver metastases as free-standing therapy or in combination with surgery as long as all visible disease can be eradicated. Percutaneous TA has been proven as a safe and efficacious therapy offering sustained local tumor control and improved patient survival. Continuous technological advances in diagnostic imaging and guidance tools, the evolution of devices allowing for optimization of ablation parameters, as well as the ability to perform margin assessment have improved the efficacy of ablation. This allows resectable small volume diseases to be cured with percutaneous ablation. The ongoing detailed information and increasing understanding of tumor biology, genetics, and tissue biomarkers that impact oncologic outcomes as well as their implications on the results of ablation have further allowed for treatment customization and improved oncologic outcomes even in those with more aggressive tumor biology. The purpose of this review is to present the most common indications for image-guided percutaneous ablation in colorectal cancer liver metastases, to describe technical considerations, and to discuss relevant peer-reviewed evidence on this topic. The growing role of imaging and image-guidance as well as controversies regarding several devices are addressed.

19.
Cardiovasc Intervent Radiol ; 44(6): 913-920, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33506278

RESUMO

PURPOSE: Predicting early local tumor progression after thermal ablation treatment for colorectal liver metastases patients is critical for the decision of subsequent follow-up and treatment. Radiomics features derived from medical images show great potential for prediction and prognosis. The aim is to develop and validate a machine learning radiomics model to predict local tumor progression based on the pre-ablation CT scan of colorectal liver metastases patients. MATERIALS AND METHODS: Ninety patients with colorectal liver metastases (140 lesions) treated by ablation were included in the study and were randomly divided into a training (n = 63 patients/n = 94 lesions) and validation (n = 27 patients/n = 46 lesions) cohort. After manual lesion volume segmentation and preprocessing, 1593 radiomics features were extracted for each lesion. Three machine learning survival models were constructed based on (1) radiomics features, (2) clinical features and (3) a combination of clinical and radiomics features to predict local tumor progression free survival. Feature reduction and machine learning modeling were performed and optimized with sequential model-based optimization. RESULTS: Median follow-up was 24 months (range 6-115). Thirty-one (22%) lesions developed local tumor progression. The concordance index in the validation set to predict local tumor progression free survival was 0.78 (95% confidence interval [CI]: 0.77-0.79) for the radiomics model, 0.56 (95%CI: 0.55-0.57) for the clinical model and 0.79 (95%CI: 0.78-0.80) for the combined model. CONCLUSION: A machine learning-based radiomics analysis of routine clinical CT imaging pre-ablation could act as a valuable biomarker model to predict local tumor progression with curative intent for colorectal liver metastases patients.


Assuntos
Ablação por Cateter , Neoplasias Colorretais/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Colorretais/cirurgia , Progressão da Doença , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento
20.
Clin Colorectal Cancer ; 20(2): e82-e95, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33246789

RESUMO

INTRODUCTION: The purpose of this study was to identify risk factors associated with local tumor progression-free survival (LTPFS) and complications after colorectal liver metastases (CLM) thermal ablation (TA). PATIENTS AND METHODS: This retrospective analysis included 286 patients with 415 CLM undergoing TA (radiofrequency and microwave ablation) in 378 procedures from January 2003 to July 2017. Prior hepatic artery infusion (HAI), bevacizumab, pre-existing biliary dilatation, ablation modality, minimal ablation margin (MM), prior hepatectomy, CLM number, and size were analyzed as factors influencing complications and LTPFS. Statistical analysis included the Kaplan-Meier method, Cox proportional hazards model, competing risk analysis, univariate/multivariate logistic/exact logistic regressions, and the Fisher exact test. Complications were reported according to modified Society of Interventional Radiology guidelines. RESULTS: The median follow-up was 31 months. There was no LTP for MM > 10 mm. Smaller tumor size, increased MM, and prior hepatectomy correlated with longer LTPFS. The major complications occurred following 28 (7%) of 378 procedures. There were no biliary complications in HAI-naive patients, versus 11% in HAI patients (P < .001), of which 7% were major. Biliary complications predictors in HAI patients included biliary dilatation, bevacizumab, and MM > 10 mm. In HAI patients, ablation with 6 to 10 mm and > 10 mm MM resulted in major biliary complication rates of 4% and 21% (P = .0011), with corresponding LTP rates of 24% and 0% (P = .0033). In HAI-naive patients, the LTP rates for 6 to 10 mm and > 10 mm MM were 27% and 0%, respectively. CONCLUSIONS: No LTP was seen for MM > 10 mm. Biliary complications occurred only in HAI patients, especially in those with biliary dilatation, bevacizumab, and MM > 10 mm. In HAI patients, MM of 6 to 10 mm resulted in 76% local tumor control and 4% major biliary complications incidence.


Assuntos
Ablação por Cateter/métodos , Neoplasias Colorretais/terapia , Hipertermia Induzida/métodos , Neoplasias Hepáticas/terapia , Idoso , Neoplasias Colorretais/patologia , Progressão da Doença , Intervalo Livre de Doença , Humanos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS