Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.401
Filtrar
1.
Plant Methods ; 20(1): 152, 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-39350157

RESUMO

Maize is the most grown feed crop in the United States. Due to wind storms and other factors, 5% of maize falls over annually. The longitudinal shear modulus of maize stalk tissues is currently unreported and may have a significant influence on stalk failure. To better understand the causes of this phenomenon, maize stalk material properties need to be measured so that they can be used as material constants in computational models that provide detailed analysis of maize stalk failure. This study reports longitudinal shear modulus of maize stalk tissue through repeated torsion testing of dry and fully mature maize stalks. Measurements were focused on the two tissues found in maize stalks: the hard outer rind and the soft inner pith. Uncertainty analysis and comparison of multiple methodologies indicated that all measurements are subject to low error and bias. The results of this study will allow researchers to better understand maize stalk failure modes through computational modeling. This will allow researchers to prevent annual maize loss through later studies. This study also provides a methodology that could be used or adapted in the measurement of tissues from other plants such as sorghum, sugarcane, etc.

2.
J R Soc Interface ; 21(219): 20240485, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39353563

RESUMO

Extracellular matrix (ECM) stiffness is fundamental in cell division, movement and differentiation. The stiffness that cells sense is determined not only by the elastic modulus of the ECM material but also by ECM geometry and cell density. We hypothesized that these factors would influence cell traction-induced matrix deformations and cellular differentiation in bone marrow stromal cells (BMSCs). To achieve this, we cultivated BMSCs on polyacrylamide hydrogels that varied in elastic modulus and geometry and measured cell spreading, cell-imparted matrix deformations and differentiation. At low cell density BMSCs spread to a greater extent on stiff compared with soft hydrogels, or on thin compared with thick hydrogels. Cell-imparted matrix deformations were greater on soft compared with stiff hydrogels or thick compared with thin hydrogels. There were no significant differences in osteogenic differentiation relative to hydrogel elastic modulus and thickness. However, increased cell density and/or prolonged culture significantly reduced matrix deformations on soft hydrogels to levels similar to those on stiff substrates. This suggests that at high cell densities cell traction-induced matrix displacements are reduced by both neighbouring cells and the constraint imposed by an underlying stiff support. This may explain observations of the lack of difference in osteogenic differentiation as a function of stiffness.


Assuntos
Diferenciação Celular , Hidrogéis , Células-Tronco Mesenquimais , Hidrogéis/química , Animais , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Matriz Extracelular/metabolismo , Resinas Acrílicas/química , Módulo de Elasticidade , Mecanotransdução Celular/fisiologia , Osteogênese/fisiologia , Células da Medula Óssea/citologia , Células da Medula Óssea/metabolismo , Células Cultivadas
3.
Sci Rep ; 14(1): 22920, 2024 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-39358414

RESUMO

An investigation into the optical and mechanical properties of a novel borate glasses with the chemical composition of 70 B2O3-10 Li2O-10ZnO-5Bi2O3-5CaO-xEu2O3 was conducted. The glassy specimens of Eu3+-doped borate were prepared by the melting-quenching technique. An enhanced density from 3.0860 to 3.2176 g cm-3 and reduced molar volume from 29.27819 to 29.17447 (cm3 mol-1) are the outcome of increasing the concentration of Eu3+ in glasses. Plotting the extinction coefficient, dielectric constant (ε1, ε2), and refractive index (n) against wavelength reveals that they all rise as level of Eu3+ elements in the glass lattice increases. An increase in Eu3+ concentration results in a decrease in both the volume (VELF) and surface (SELF) energy loss functions. Also, all elastic-mechanical moduli (such as Young's, Bulk, Shear, and Elongation) increase with increasing the quantity of Eu3+ ions in the glass lattice. The Young's modulus (Y, GPa) of the glassy specimens was 34.512, 36.089, 36.504, 36.730 and 37.114 GPa for x equal 0, 0.25, 0.5, 0.75 and 1 mol ratio in the glass system, and coded by Eu-0.0, Eu-0.25, Eu-0.5, Eu-0.75 and Eu-1.0, respectively. Growing Eu2O3 levels resulted in an increase in Micro-Hardness from 2.050 to 2.146 GPa. Poisson's ratio values for Eu-0.0, Eu-0.250, Eu-0.5, Eu-0.75 and Eu-1.0 were 0.273, 0.275, 0.277, 0.277 and 0.278, respectively.

4.
Nanotechnology ; 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39374624

RESUMO

Nanoscale materials tend to have a single crystal domain, leading to not only size dependence but also orientation dependence of their mechanical properties. Recently, we developed a microscopic nanomechanical measurement method (MNMM), which enabled us to obtain equivalent spring constants (force gradients) of nanocontacts while observing their atomic structures by transmission electron microscopy (TEM). Therein, we evaluated Young's modulus based on a model that a newly introduced layer at the thinnest section of a nanocontact determined the change in the measured equivalent spring constant, and discussed their size dependence. However, this model is not general for other nanomaterials that do not exhibit the introduction of a new atomic layer while stretching. In this study, using MNMM, we propose a new analytical method to directly retrieve the local Young's modulus of nanomaterials by measuring initial lattice spacing and its displacement of a local region in the TEM image during the stretching of the nanocontact. This reveals the size dependence of local Young's modulus at various positions of the nanocontact at once. As a result, our estimated Young's modulus for a gold [111] nanocontact showed a size dependence similar to the one previously reported. This indicates that this analytical method benefits in revealing the mechanical properties of not only nanomaterials but also structurally heterogeneous materials such as high-entropy alloys. .

5.
Acta Biomater ; 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39379233

RESUMO

Living tissues each exhibit a distinct stiffness, which provides cells with key environmental cues that regulate their behaviors. Despite this significance, our understanding of the spatiotemporal dynamics and the biological roles of stiffness in three-dimensional tissues is currently limited due to a lack of appropriate measurement techniques. To address this issue, we propose a new method combining upright structured illumination microscopy (USIM) and atomic force microscopy (AFM) to obtain precisely coordinated stiffness maps and biomolecular fluorescence images of thick living tissue slices. Using mouse embryonic and adult skin as a representative tissue with mechanically heterogeneous structures inside, we validate the measurement principle of USIM-AFM. Live measurement of tissue stiffness distributions revealed the highly heterogeneous mechanical nature of skin, including nucleated/enucleated epithelium, mesenchyme, and hair follicle, as well as the role of collagens in maintaining its integrity. Furthermore, quantitative analysis comparing stiffness distributions in live tissue samples with those in preserved tissues, including formalin-fixed and cryopreserved tissue samples, unveiled the distinct impacts of preservation processes on tissue stiffness patterns. This series of experiments highlights the importance of live mechanical testing of tissue-scale samples to accurately capture the true spatiotemporal variations in mechanical properties. Our USIM-AFM technique provides a new methodology to reveal the dynamic nature of tissue stiffness and its correlation with biomolecular distributions in live tissues and thus could serve as a technical basis for exploring tissue-scale mechanobiology. STATEMENT OF SIGNIFICANCE: Stiffness, a simple mechanical parameter, has drawn attention in understanding the mechanobiological principles underlying the homeostasis and pathology of living tissues. To explore tissue-scale mechanobiology, we propose a technique integrating an upright structured illumination microscope and an atomic force microscope. This technique enables live measurements of stiffness distribution and fluorescent observation of thick living tissue slices. Experiments revealed the highly heterogeneous mechanical nature of mouse embryonic and adult skin in three dimensions and the previously unnoticed influences of preservation techniques on the mechanical properties of tissue at microscopic resolution. This study provides a new technical platform for live stiffness measurement and biomolecular observation of tissue-scale samples with micron-scale resolution, thus contributing to future studies of tissue- and organ-scale mechanobiology.

6.
Sci Rep ; 14(1): 23219, 2024 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-39369051

RESUMO

In this work, Hui-Shia model is developed to reveal the efficiency of a deficient interphase on the tensile modulus of polymer halloysite nanotube (HNT) nanocomposites. "Lc" as essential HNT length providing full stress transferring is defined and effective HNT size, effective HNT concentration, and efficiency of stress transferring (Q) are expressed by "Lc". Furthermore, the influences of all terms on the "Q" and nanocomposite's modulus are clarified, and also the calculations of the model are linked to the tested data of some nanocomposites. Original Hui-Shia model overpredicts the moduli, but the innovative model's predictions appropriately fit the measured data. Lc = 200 nm maximizes the sample's modulus to 2.6 GPa, but the modulus reduces to 2.11 GPa at Lc = 700 nm. Therefore, there is a reverse relation between the sample's modulus and "Lc". Q = 0.5 produces the system's modulus of 2.1 GPa, while the modulus of 2.35 GPa is achieved at Q = 1 providing a direct relation between the nanocomposite's modulus and "Q". Generally, narrow and big HNTs, along with a low "Lc", enhance the "Q", because a lower "Lc", reveals a tougher interphase improving the stress transferring.

7.
Micromachines (Basel) ; 15(9)2024 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-39337835

RESUMO

Micro-nano-scale mechanical properties are vital for engineering and biological materials. The elastic modulus is generally measured by processing the force-indentation curves obtained by atomic force microscopy (AFM). However, the measurement precision is largely affected by tip shape, tip wear, sample morphology, and the contact model. In such research, it has been found that the radius of the sharp tip increases due to wear during contact scanning, affecting elastic modulus calculations. For flat-ended tips, it is difficult to identify the contact condition, leading to inaccurate results. Our research team has invented a nano-spherical tip, obtained by implanting focused helium ions into a silicon microcantilever, causing it to expand into a silicon nanosphere. This nano-spherical tip has the advantages of sub-micro size and a smooth spherical surface. Comparative tests of the elastic modulus measurement were conducted on polytetrafluoroethylene (PTFE) and polypropylene (PP) using these three tips. Overall, the experimental results show that our nano-spherical tip with a consistent tip radius, symmetrical geometric shape, and resistance to wear and contamination can improve precision in elastic modulus measurements of polymer materials.

8.
Sensors (Basel) ; 24(18)2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39338881

RESUMO

Although the physical properties of a structure, such as stiffness, can be determined using some statical tests, the identification of damping parameters requires a dynamic test. In general, both theoretical prediction and experimental identification of damping are quite difficult. There are many different techniques available for damping identification, and each method gives a different damping parameter. The dynamic indentation method, rheometry, atomic force microscopy, and resonant vibration tests are commonly used to identify the damping of materials, including soft materials. While the viscous damping ratio, loss factor, complex modulus, and viscosity are quite common to describe the damping of materials, there are also other parameters, such as the specific damping capacity, loss angle, half-power bandwidth, and logarithmic decrement, to describe the damping of various materials. Often, one of these parameters is measured, and the measured parameter needs to be converted into another damping parameter for comparison purposes. In this review, the theoretical derivations of different parameters for the description and quantification of damping and their relationships are presented. The expressions for both high damping and low damping are included and evaluated. This study is considered as the first comprehensive review article presenting the theoretical derivations of a large number of damping parameters and the relationships among many damping parameters, with a quantitative evaluation of accurate and approximate formulas. This paper could be a primary resource for damping research and teaching.

9.
Polymers (Basel) ; 16(18)2024 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-39339025

RESUMO

Currently available intraocular lenses (IOLs) on the market often differ significantly in elastic modulus compared to the natural human lens, which impairs their ability to respond effectively to the tension of the ciliary muscles for focal adjustment after implantation. In this study, we synthesized a polyacrylamide-sodium acrylate hydrogel (PAH) through the cross-linking polymerization of acrylamide and sodium acrylate. This hydrogel possesses excellent biocompatibility and exhibits several favorable properties. Notably, the hydrogel demonstrates high transparency (94%) and a refractive index (1.41 ± 0.07) that closely matches that of the human lens (1.42). Additionally, it shows strong compressive strength (14.00 kPa), good extensibility (1400%), and an appropriate swelling ratio (50 ± 2.5%). Crucially, the tensile modulus of the hydrogel is 2.07 kPa, which closely aligns with the elastic modulus of the human lens (1.70-2.10 kPa), enabling continuous focal adjustment under the tension exerted by the ciliary muscles.

10.
Exp Eye Res ; 248: 110095, 2024 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-39284506

RESUMO

The purpose of this study is to investigate whether the iontophoresis-assisted riboflavin delivery to posterior sclera with less delivery time, can achieve the same riboflavin permeation efficiency as the passive soaking way, and its effect on the mechanical properties of posterior sclera for accelerated scleral collagen cross-linking (A-SXL). In this study, 0.1% riboflavin solution was applied into the posterior sclera of porcine eyes either by the iontophoresis-assisted or passive soaking method, with delivery time of 5, 7.5, 10, 12.5, 15, 17.5, and 20 min, respectively. The fluorescence intensity and the distribution of riboflavin concentration in the 10 µm frozen sections of the sclera were evaluated by fluorescence inverted microscope. The posterior sclera with riboflavin treatment through either the iontophoresis-assisted or the passive soaking method for different durations ranging from 5 to 20 min was treated with ultraviolet A (UVA) irradiation at an intensity of 10 mW/cm2 for 9 min. The elastic modulus was determined at the physiological strain level using the uniaxial tensile test after ASXL. The results showed that the fluorescence intensity of riboflavin increased by prolonging the delivery time in both the iontophoresis and passive soaking groups, and the permeation depth of riboflavin remained constant over 15 min. The fluorescence intensity in the iontophoresis group was significantly higher than in the passive soaking group at 12.5 min and 15 min, respectively. The elastic modulus at 12.5 min in the iontophoresis group was significantly higher than in the passive soaking group at the same delivery time and showed no significant difference compared to the passive soaking group at 20 min. In conclusion, it indicated that iontophoresis-assisted delivery could not only shorten the surgery time but also achieve similar mechanical performance to the passive soaking method in ASXL.

11.
World J Clin Cases ; 12(26): 5922-5929, 2024 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-39286384

RESUMO

BACKGROUND: Real-time shear wave elastography (SWE) is a non-invasive imaging technique used to measure tissue stiffness by generating and tracking shear waves in real time. This advanced ultrasound-based method provides quantitative information regarding tissue elasticity, offering valuable insights into the mechanical properties of biological tissues. However, the application of real-time SWE in the musculoskeletal system and sports medicine has not been extensively studied. AIM: To explore the practical value of real-time SWE for assessing Achilles tendon hardness in older adults. METHODS: A total of 60 participants were enrolled in the present study, and differences in the elastic moduli of the bilateral Achilles tendons were compared among the following categories: (1) Age: 55-60, 60-65, and 65-70-years-old; (2) Sex: Male and female; (3) Laterality: Left and right sides; (4) Tendon state: Relaxed and tense state; and (5) Tendon segment: Proximal, middle, and distal. RESULTS: There were no significant differences in the elastic moduli of the bilateral Achilles tendons when comparing by age or sex (P > 0.05). There were, however, significant differences when comparing by tendon side, state, or segment (P < 0.05). CONCLUSION: Real-time SWE plays a significant role compared to other examination methods in the evaluation of Achilles tendon hardness in older adults.

12.
Saudi Dent J ; 36(9): 1215-1220, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39286579

RESUMO

Purpose: This study investigated the fracture resistance and failure modes of custom-fabricated post- and core dental restorations using various CAD/CAM materials. Materials and Methods: Seventy-five mandibular second premolars were allocated to five groups (n = 15) and prepared for standardized post and core restorations. The groups included a control group comprising cast metal and four CAD/CAM materials: Vita Enamic, Shofu HC, Trilor, and PEKK. Fracture resistance was assessed using a compressive force at a crosshead speed of 1 mm/min until failure occurred. Data were analyzed using one-way analysis of variance (ANOVA) and chi-square tests. Results: The metal group had the highest fracture resistance (244.41 ± 75.20 N), with a significant variance compared to that in the CAD/CAM groups (p < 0.001). No significant differences were observed among the non-metallic groups. Conclusions: While several CAD/CAM materials displayed satisfactory flexural properties, cast metal posts showed superior fracture resistance in endodontically treated teeth but were mostly associated with catastrophic failure. The clinical application of CAD/CAM materials for post-core restorations presents a viable alternative to traditional metal posts, potentially reducing the risk of unfavorable fractures.

13.
J Sports Sci Med ; 23(1): 684-689, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39228783

RESUMO

Foam rolling have gained popularity among elite athletes, but the effect of the speed parameter of foam rolling has not yet been determined. Our objective was to investigate the impact of different application speeds of foam roller on the mechanical properties of the quadriceps femoris muscle. Eighteen male professional basketball athletes (age 23 ± 4 years, body mass index 24.43 ± 1.59 kg/m2) participated in this study. We used a crossover design to randomize the order of the treatment speeds (30 beats per minute-FAST, 15 beats per minute-SLOW, and a self-determined speed-SELF) with a one-week washout period between each session. We measured dominant quadriceps femoris muscle tone, elasticity, and stiffness using the Myoton device before and after the interventions. We found that the average rate for SELF was 33±10 beats per minute, making SELF the fastest. All application speeds showed similar results in pre-intervention measurements of the mechanical properties of the tissues (P > 0.05). However, post hoc analysis revealed that a decrease was evident in SLOW compared to SELF in muscle tone in post-intervention measurements (P = 0.037). Also, we noted that comparison of pre- and post-intervention on FAST and SLOW showed a significant reduction in muscle tone (P = 0.002, P = 0.008). Slower foam rolling prior to training or competition may lead to a delay in the reaction time due to the reduction in tonus, that can increase the injury risks. Alternatively, the significant reduction in tonus may be useful in regulating the increased tonus after training and competition.


Assuntos
Basquetebol , Estudos Cross-Over , Músculo Quadríceps , Humanos , Masculino , Músculo Quadríceps/fisiologia , Adulto Jovem , Basquetebol/fisiologia , Fenômenos Biomecânicos , Adulto , Elasticidade , Tono Muscular/fisiologia
14.
Sci Rep ; 14(1): 21010, 2024 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-39251655

RESUMO

The mechanical properties of the sclera play a critical role in supporting the ocular structure and maintaining its shape. However, non-invasive measurements to quantify scleral biomechanics remain challenging. Recently introduced multi-directional optical coherence elastography (OCE) combined with an air-coupled ultrasound transducer for excitation of elastic surface waves was used to estimate phase speed and shear modulus in ex vivo rabbit globes (n = 7). The scleral phase speed (12.1 ± 3.2 m/s) was directional-dependent and higher than for corneal tissue (5.9 ± 1.4 m/s). In the tested locations, the sclera proved to be more anisotropic than the cornea by a factor of 11 in the maximum of modified planar anisotropy coefficient. The scleral shear moduli, estimated using a modified Rayleigh-Lamb wave model, showed significantly higher values in the circumferential direction (65.4 ± 31.9 kPa) than in meridional (22.5 ± 7.2 kPa); and in the anterior zone (27.3 ± 9.3 kPa) than in the posterior zone (17.8 ± 7.4 kPa). The multi-directional scanning approach allowed both quantification and radial mapping of estimated parameters within a single measurement. The results indicate that multi-directional OCE provides a valuable non-invasive assessment of scleral tissue properties that may be useful in the development of improved ocular models, the evaluation of potential myopia treatment strategies, and disease characterization and monitoring.


Assuntos
Técnicas de Imagem por Elasticidade , Esclera , Tomografia de Coerência Óptica , Animais , Coelhos , Esclera/diagnóstico por imagem , Esclera/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Tomografia de Coerência Óptica/métodos , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Córnea/fisiologia , Módulo de Elasticidade
15.
Sci Rep ; 14(1): 21051, 2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39251673

RESUMO

This paper proposes a new impulse excitation technique using a square plate. First, the functional relationship between the modal frequency of the specimen and the geometrical dimensions and mechanical parameters was established by using the finite element method. Then, the continuous functional relationship derived by a homotopy method allowed the frequency ratios to be related to the thickness-to-length ratio and Poisson's ratio. By measuring the frequency ratios and thickness-to-length ratio, Poisson's ratio could be calculated using this functional relationship. When the density and Poisson's ratio were known, Young's modulus could be identified inversely in conjunction with the finite element analysis. Finally, a comparison test between this method and the traditional impulse excitation technique was designed and implemented, and the results showed that this method has advantages in both testing efficiency and accuracy. The study provides a new idea for system identification, which has important application value and promotion significance.

16.
Dent Mater ; 2024 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-39271304

RESUMO

OBJECTIVES: The aim of this study was to determine the viscoelastic performance and energy dissipation of conditioned dentin infiltrated with polymeric nanoparticles (NPs) doped with tideglusib (TDg) (TDg-NPs). METHODS: Dentin conditioned surfaces were infiltrated with NPs and TDg-NPs. Bonded interfaces were created, stored for 24 h and submitted to mechanical and thermal challenging. Resin-dentin interfaces were evaluated through nano-DMA/complex-loss-storage moduli-tan delta assessment and atomic force microscopy (AFM) analysis. RESULTS: Dentin infiltrated with NPs and load cycled attained the highest complex modulus at hybrid layer and bottom of hybrid layer. Intertubular dentin treated with undoped NPs showed higher complex modulus than peritubular dentin, after load cycling, provoking energy concentration and breakdown at the interface. After infiltrating with TDg-NPs, complex modulus was similar between peri-intertubular dentin and energy dissipated homogeneously. Tan delta at intertubular dentin was higher than at peritubular dentin, after using TDg-NPs and load cycling. This generated the widest bandwidth of the collagen fibrils and bridge-like mineral structures that, as sight of energy dissipation, fastened active dentin remodeling. TDg-NPs inducted scarce mineralization after thermo-cycling, but these bridging processes limited breakdown zones at the interface. SIGNIFICANCE: TDg-based NPs are then proposed for effective dentin remineralization and tubular seal, from a viscoelastic approach.

17.
Rev Bras Ortop (Sao Paulo) ; 59(4): e556-e563, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39239578

RESUMO

Objective To analyze the mechanical properties of the patellar (PT) and semitendinosus (ST) tendons from fresh-frozen human cadavers from a tissue bank using supersonic shear-wave imaging (SSI) elastography and tensile tests. Methods We tested seven PT and five ST samples on a traction machine and performed their simultaneous assessment through SSI. The measurements enabled the comparison of the mechanical behavior of the tendons using the stress x strain curve and shear modulus (µ) at rest. In addition, we analyzed the stress x µ relationship under tension and tested the relationship between these parameters. The statistical analysis of the results used unpaired t -tests with Welch correction, the Pearson correlation, and linear regression for the Young modulus (E) estimation. Results The µ values for the PT and ST at rest were of 58.86 ± 5.226 kPa and 124.3 ± 7.231 kPa respectively, and this difference was statistically significant. The correlation coefficient between stress and µ for the PT and ST was very strong. The calculated E for the PT and ST was of 19.97 kPa and 124.8 kPa respectively, with a statistically significant difference. Conclusion The ST was stiffer than the PT in the traction tests and SSI evaluations. The µ value was directly related to the stress imposed on the tendon. Clinical relevance The present is an evaluation of the mechanical properties of the tendons most used as grafts in knee ligament reconstruction surgeries.

18.
J Clin Pediatr Dent ; 48(5): 131-137, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39275830

RESUMO

Recently, interest in tooth-colored fluoride-releasing dental materials has increased. Although physical and mechanical properties such as surface hardness, elastic modulus and surface roughness of the restorative materials have been investigated, the effect of different immersion media on these properties is still controversial. The aim of this study was to evaluate the nanohardness, elastic modulus and surface roughness of the fluoride release of tooth-colored restorative materials after immersion in acidic beverages. Prepared samples of three restorative materials (a highly viscous glass ionomer (EQUIA Forte; GC, Tokyo, Japan), a compomer (Dyract XP; Dentsply, Weybridge, UK), and a bioactive restorative material (Activa BioACTIVE; Pulpdent, MA, USA)) were randomly divided and immersed in distilled water, a cola and an orange juice for one week. The HYSITRON T1 950 TriboIndenter device (Hysitron, USA) with the Berkovich diamond indenter tip was used for all measurements. The nanohardness and elastic modulus of the samples were measured by applying a force of 6000 µN to five different points on the sample surface. Surface roughness measurements were evaluated on random samples by scanning five random 40 × 40 µm areas. The properties were measured at the initial and one week after immersion. The values of nanohardness, elastic modulus and surface roughness were tested for significant differences using a two-way analysis of variance (ANOVA) with repeated measures (p < 0.05). Tukey's honest significant difference (HSD) test was used for multiple comparisons. AB (Activa BioACTIVE) had the highest initial mean values for nanohardness. After post-immersion, the highest mean value for elastic modulus was the initial AB value. The lowest mean value for roughness of 100.36 nm was obtained for the initial DX (Dyract XP) measurement. Acidic beverages had a negative effect on the nanohardness, elastic modulus and surface roughness of the restorative materials.


Assuntos
Bebidas Gaseificadas , Módulo de Elasticidade , Fluoretos , Dureza , Teste de Materiais , Propriedades de Superfície , Fluoretos/química , Compômeros/química , Humanos , Materiais Dentários/química , Sucos de Frutas e Vegetais , Resinas Acrílicas/química , Restauração Dentária Permanente/métodos , Água/química , Cariostáticos/química , Cimentos de Ionômeros de Vidro/química , Citrus sinensis/química , Imersão , Resinas Compostas/química , Dióxido de Silício
19.
ChemSusChem ; : e202401535, 2024 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-39243152

RESUMO

Anode-free Lithium metal batteries, with their high energy density (>500 Wh/kg), are emerging as a promising solution for high-energy-density rechargeable batteries. However, the Coulombic Efficiency and capacity often decline due to interface side reactions. To address this, a lithiophilic layer is introduced, promoting stable and uniform Li deposition. Despite its effectiveness, this layer often undergoes electrochemical deactivation over time. This work investigates lithiophilic silver (Ag), prepared via magnetron sputtering on a copper (Cu) current collector. Finite element simulations identify stress changes from alloying reactions as a key cause of Ag particle pulverization and deactivation. A high Young's modulus coating layer is proposed to mitigate this. The Ag2TiO3@Ag@TiO2@Cu composite electrode, designed with multi-layer structures, demonstrates a slower deactivation process through galvanostatic electrochemical cycling. Characterization methods such as SEM, AFM, and TEM confirm the suppression of Ag particle pulverization, while uncoated Ag fractures and deactivates. This work uncovers a potential failure mechanism of lithiophilic metallic nanoparticles and proposes a strategy for deactivation suppression using an artificial coating layer.

20.
J Voice ; 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39244387

RESUMO

The elastic properties of the folds govern the characteristics of vocal fold vibrations. This study addresses existing gaps by investigating the Young's modulus along the anterior-posterior direction in excised canine and cadaveric human vocal folds. Micro-indentation testing was conducted on six excised canines and three cadaveric human larynges. Multiple points along the medial glottal wall were indented to determine force-displacement, stress-strain relationships, and Young's modulus as a function of Green's strain. A vertical stiffness gradient was consistently observed in both canine and human samples, with higher stiffness in the inferior aspect compared with the superior aspect. The stiffness increased toward both the anterior and posterior directions from the mid-coronal plane, with a more pronounced increase at the posterior edge. Human vocal folds generally exhibited lower stiffness at low strains but were comparable to canine vocal folds at higher strains. These findings suggest that the canine larynx model is a reasonable representation of the human laryngeal tissues' elastic property trends. This analysis of the vertical stiffness gradient in canine and human vocal folds provides valuable data for improving experimental and numerical models of phonation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA