Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Mar Pollut Bull ; 181: 113899, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35839664

RESUMO

Southeast Brazilian bays have been increasingly degraded by untreated organic loads. Therefore, to assess fecal contamination status, sediment quality regarding polycyclic aromatic hydrocarbons (PAHs), and sources of organic matter (OM), we have determined fine-grained and total organic carbon (TOC) content and concentrations of PAHs and sterols in twenty-six surface sediment samples in Sepetiba Bay. The fine-grained (1-26 %), TOC (0.20-3.45 %), PAHs (

Assuntos
Hidrocarbonetos Policíclicos Aromáticos , Poluentes Químicos da Água , Baías , Brasil , Monitoramento Ambiental/métodos , Sedimentos Geológicos , Hidrocarbonetos Policíclicos Aromáticos/análise , Esteróis/análise , Poluentes Químicos da Água/análise
2.
Mikrochim Acta ; 189(3): 108, 2022 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-35171382

RESUMO

Methyl nicotinate (MN) is a representative and typical volatile organic marker of Mycobacterium tuberculosis, and the specific detection of MN in human breath facilitates non-invasive, rapid, and accurate epidemic screening of tuberculosis infection. Herein, we constructed a fluorescent assay consisted of CdTe quantum dots (QD) and cobalt-metalized tetrakis(4-carboxyphenyl) porphyrin (CoTCPP) nanosheets to determine methyl nicotinate (MN) in vapor samples. Red-emission QD (λex=370 nm, λem=658 nm) acts as signal switches whose fluorescence signals can be effectively quenched by CoTCPP nanosheets but restored in the presence of MN. The strategy relied on the distinct binding affinity of cobalt ion and MN. MN restored the fluorescence of QD quenched by CoTCPP in a concentration-dependent manner, which exhibited a well-linear relationship in the range 1-100 µM, and a limit of detection of 0.59 µM. The proposed platform showed sensitivity and selectivity to detect MN in vapor samples with satisfactory RSD below 3.33%. The method is cheap, simple, and relatively rapid (detected within 4 min), which suggests a potential in tuberculosis diagnosis in resource- and professional-lacked areas.


Assuntos
Compostos de Cádmio/química , Mycobacterium tuberculosis/química , Nanopartículas/química , Ácidos Nicotínicos/análise , Porfirinas/química , Pontos Quânticos/química , Telúrio/química , Biomarcadores/análise , Humanos , Espectrometria de Fluorescência , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA