Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70.308
Filtrar
1.
Nurs Womens Health ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38968958

RESUMO

OBJECTIVE: To compare the efficacy of foot reflexology and Benson's relaxation on anxiety and physiologic parameters after cesarean surgery. DESIGN: Randomized controlled trial with three parallel arms. SETTING: Gynecologic ward of the Persian Gulf Martyrs Hospital in Bushehr, Iran, in 2020. PARTICIPANTS AND INTERVENTIONS: Women undergoing cesarean surgery (n = 135) were selected by convenience sampling and divided via block randomization into three groups of foot reflexology, Benson's relaxation interventions, and control group (n = 45 in each group). Interventions were performed 2 hours after cesarean surgery. MEASUREMENTS: Spielberger's State-Trait Anxiety Inventory, mercury sphygmomanometer, and pulse oximeter were used to collect the data. Anxiety was measured before and 30 minutes after the intervention. Physiologic parameters were measured before the intervention and immediately, 30 minutes, and 60 minutes after the intervention. Data were analyzed using inferential statistics. RESULTS: The mean score of situational anxiety after the intervention was significantly lower than before the intervention in the reflexology (t = 6.171; 95% confidence interval [CI] [5.66, 11.14]) and Benson's relaxation groups (t = 7.362; 95% CI [5.91, 9.85]). However, changes in the control group were not significant (t = 1.674; 95% CI [-0.24, 2.55]). Decreases in anxiety scores were similar in the two intervention groups. After intervention, in most measurement times, respiratory rate and pulse rate decreased in the two intervention groups compared to the control group, and arterial oxygen saturation and systolic blood pressure increased. CONCLUSION: Considering the effect of both interventions on decreasing anxiety and improving most physiologic parameters, it seems that foot reflexology and Benson's relaxation can be recommended after cesarean surgery.

2.
Nano Lett ; 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007901

RESUMO

PdSe2 is a puckered transition metal dichalcogenide that has been reported to undergo a two-dimensional to three-dimensional structural transition under pressure. Here, we investigated the electronic and phononic evolution of PdSe2 under high pressure using pump-probe spectroscopy. We observed the electronic intraband and interband transitions occurring in the d orbitals of Pd, revealing the disappearance of the Jahn-Teller effect under high pressure. Furthermore, we found that the decay rates of interband recombination and intraband relaxation lifetimes change at 3 and 7 GPa, respectively. First-principles calculations suggest that the bandgap closure slows the decay rate of interband recombination after 3 GPa, while the saturation of phonon-phonon scattering is the main reason for the relatively constant intraband relaxation lifetime. Our work provides a novel perspective for understanding the evolution of the electron and modulation of the carrier dynamics by phonons under pressure.

3.
Nurs Crit Care ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38955490

RESUMO

BACKGROUND: Clinical practice guidelines for the prevention of catheter associated urinary tract infection (CAUTI) recommend urinary catheter securement in critical patients although there is scant research on its effectiveness. AIM: To analyse whether securement of an indwelling urinary catheter (IUC) reduces the risk of CAUTI and meatal pressure injury among intensive care unit (ICU) patients and assess medical adhesive-related skin injury (MARSI) associated with the securement device. STUDY DESIGN: Open randomized controlled trial involving patients admitted to two ICUs in Spain. In the intervention group (n = 169 patients), the IUC was secured to the thigh using an in-house device piloted as part of this trial. Controls (n = 181) received standard care, including non-securement of the IUC. Barrier film spray was applied to the securement site with the aim of preventing MARSI. The definitions of the main outcomes were: CAUTI was diagnosed according to the criteria of the European Centre for Disease Prevention and Control, meatal pressure injury was categorized into four grades and MARSI was classified as either erythema or skin tears. Bivariate analysis and multivariate logistic regression were performed. Log-rank and Cox regressions were used to compare risk over time to CAUTI and meatal pressure injury in the two groups. RESULTS: Data from 350 patients were analysed, 169 (48.29%) from IG and 181 (51.71%) from CG. In the multiple logistic regression analysis, IUC securement was an independent protective factor against both CAUTI (RR = 0.2, 95% CI [0.05, 0.67]) and meatal pressure injury (RR = 0.31, 95% CI [0.15, 0.58]). The incidence of MARSI was 7.1%. CONCLUSION: Effective IUC securement significantly reduces the risk of CAUTI and meatal pressure injury among ICU patients. The in-house device piloted in the present trial is simple for nurses to use, and the incidence of MARSI was low. These results underline the benefits of IUC securement. RELEVANCE TO CLINICAL PRACTICE: Indwelling urinary catheter (IUC) securement reduces the risk of urinary tract infection. IUC securement helps prevent meatal pressure injury. IUC securement with in-house devices is safe and effective.

5.
J Tissue Viability ; 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38955662

RESUMO

OBJECTIVE: The purpose of this study is to determine family caregivers' level of knowledge on pressure injury (PI) prevention. METHODS: This study used a cross-sectional and descriptive design. Data were collected between February and May 2023. The population of the study consisted of family caregivers providing care to patients who were at risk of developing pressure injuries and who were planned to be discharged from the inpatient wards of the hospital. A total of 105 family caregivers participated in the study. RESULTS: Of all the patients, 61.9 % (n = 65) were female and their average age was 68.96 years (SD = 18.07). While 30.48 % (n = 32) of the patients were bedridden due to Cerebrovascular Accident, 28.57 % (n = 30) were bedridden due to old age, and 28.57 % (n = 30) had PI. Of all the caregivers, 71.43 % (n = 75) were female, and their average age was 47.11 years (SD = 14.85). While 97.14 % (n = 96) of the caregivers had not received any training on PI before, 90.48 % (n = 95) had not provided care to a patient with PI before. Family caregivers scored an average of 22.25 (SD = 6.96) points out of 40 on the Pressure Injury Prevention Knowledge Test (PIPKT). A significant difference was detected between the knowledge test scores and education level and income level (P = 0.006; P = 0.002). CONCLUSIONS: Family caregivers were found to need information about PI prevention. It is recommended to develop content on PI prevention in the guidelines for family caregivers.

6.
Trauma Case Rep ; 52: 101059, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38957177

RESUMO

A male in his early 30s was transported to the emergency room after being hit by a vehicle while inebriated and lying in the street. His general condition was stable; however, he had a perineal laceration that extended to the coccyx. Due to the proximity of the wound margin to the anus, we were concerned regarding the potential contamination and opted not to suture it. Therefore, we refrained from suturing the wound and kept the wound open after irrigation and debridement. Additionally, we performed a transverse colostomy. On day 4, we initiated negative pressure wound therapy for 40 days, during which sufficient wound granulation occurred. The patient was discharged, and the colostomy was closed approximately 4 months after the injury. Our case illustrates the effectiveness of negative pressure wound therapy in managing perineal lacerations.

7.
Cureus ; 16(6): e61514, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38957251

RESUMO

Background Newborns frequently experience respiratory distress (RD), necessitating preventive management during transportation. The use of Continuous Positive Airway Pressure (CPAP) is crucial in mitigating RD in neonates, particularly during transit. This study aims to assess the feasibility and efficacy of utilizing a RAM cannula (Neotech Products, Valencia, USA) with a T-piece resuscitator to deliver CPAP during neonatal transport. The objective is to evaluate the response of transported neonates to this intervention, including improvements in distress, surfactant requirements, ventilator dependency, and complications. Method and material Neonates with RD qualifying for CPAP support at birth and requiring transport to Neonatal Intensive Care Unit (NICU) care were included. The average duration of transport was 38 minutes (range 12 minutes to 2 hours). RAM cannula with a T-piece resuscitator was used for CPAP delivery during transportation. Vital parameters and interventions were monitored during transit, and outcomes were compared with inborn neonates receiving standard CPAP in the labor room. Results Out of 48 babies, nine babies required surfactant, and four needed invasive ventilation, with three developing a nasal injury. Compared to in-house preterm babies, these babies had more Positive End Expiratory Pressure (PEEP) knob adjustment, desaturation episodes, late surfactant administration, and intubation needs. Conclusion A high-flow nasal cannula combined with a T-piece resuscitator emerges as a promising modality for CPAP delivery during neonatal transportation, demonstrating efficacy with minimal complications.

8.
Front Cardiovasc Med ; 11: 1388313, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38957328

RESUMO

Background: Hypertension is the most significant global risk factor for mortality and morbidity, making standardized blood pressure measurement crucial. Objectives: To investigate whether the location of blood pressure monitors and the positioning of cuffs yield differing results in blood pressure measurements. Methods: Patients admitted to the Affiliated Hospital of Jiujiang College between 1 January 2022 and 30 June 2023 were enrolled in this study and randomly allocated into four groups. These groups were defined based on the positioning of monitoring equipment as follows: varied placements of cuffs on automatic blood pressure monitors, different heights for mercury column blood pressure monitors, varied heights for automatic blood pressure monitors, and different orientations for the cuff airbag tubes on electrocardiogram monitors. Blood pressure was measured and recorded for each group, followed by an analysis of the variations in readings across the different setups. Results: In the first cohort of 763 individuals, mean systolic blood pressure measured at the standard upper arm site was 128.8 ± 10.5 mmHg, compared to 125.3 ± 10.4 mmHg at the elbow fossa. The corresponding diastolic pressures were 79.2 ± 10.7 and 75.0 ± 10.6 mmHg, respectively. The difference in systolic pressure between these positions was significant at 3.48 ± 3.22 mmHg (t1 = 29.91, p1 < 0.001) and for diastolic pressure at 4.23 ± 1.31 mmHg (t2 = 88.98, p2 < 0.001). For the subsequent groups, involving 253, 312, and 225 individuals, respectively, blood pressure measurements were analyzed and compared across different methods within each group. All p-values exceeded 0.05, indicating no statistically significant differences. Conclusions: Blood pressure values measured at the elbow fossa position using an upper arm-type automatic sphygmomanometer were found to be lower than those measured at the upper arm position, with a difference of 3.48 mmHg for systolic and 4.23 mmHg for diastolic pressures. It is therefore essential to position the cuff correctly, specifically 2-3 cm above the elbow fossa, when utilizing an upper arm-type automatic sphygmomanometer for blood pressure monitoring. Conversely, the placement of the mercury column sphygmomanometer and the automated sphygmomanometer at varying heights had no significant effect on blood pressure readings. Similarly, the orientation of the electrocardiogram's cuffed balloon tube, whether facing upward or downward, did not influence blood pressure measurement outcomes.

10.
Hypertens Res ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965426

RESUMO

The contrasting relationships of plant and animal protein intake with blood pressure (BP) may be partially attributed to the differential non-protein (e.g., saturated fat and fibre) and amino acid (AA) compositions. This study determined whether animal and plant protein intake were related to differential metabolomic profiles associated with BP. This study included 1008 adults from the African-PREDICT study (aged 20-30 years). Protein intake was determined using 24-h dietary recalls. Twenty-four-hour ambulatory BP was measured. Amino acids and acylcarnitines were analysed in spot urine samples using liquid chromatography-tandem mass spectrometry-based metabolomics. Participants with a low plant, high animal protein intake had higher SBP (by 3 mmHg, p = 0.011) than those with high plant, low animal protein intake (low-risk group). We found that the relationships of plant and animal protein intake with 24-h SBP were partially mediated by BMI and saturated fat intake, which were independently associated with SBP. Protein intake was therefore not related to SBP in multiple regression analysis after adjusting for confounders. In the low-risk group, methionine (Std. ß = -0.217; p = 0.034), glutamic acid (Std. ß = -0.220; p = 0.031), glycine (Std. ß = -0.234; p = 0.025), and proline (Std. ß = -0.266; p = 0.010) were inversely related to SBP, and beta-alanine (Std. ß = -0.277; p = 0.020) to DBP. Ultimately a diet high in animal and low in plant protein intake may contribute to higher BP by means of increased BMI and saturated fat intake. Conversely, higher levels of urinary AAs observed in adults consuming a plant rich diet may contribute to lower BP.

11.
Nurs Crit Care ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965753

RESUMO

BACKGROUND: Nurses are vital in identifying and preventive pressure injuries (PIs) in hospitalized patients undergoing open heart surgery. Interventions to prevent PIs are crucial for every critical patient, and it's essential to recognize that preventing PIs involves a complex intervention. AIM: To examine the nursing interventions for the prevention of PI in patients with open heart surgery. METHOD: A systematic review study. Web of Science, Science Direct, PubMed, Scopus, MEDLINE Ultimate, CINAHL Ultimate, ULAKBIM, Cochrane Library, Google Scholar and university library databases were scanned. The initial search performed in the databases was updated on 4 February 2023, and on 7 April 2024, for potential publications included in that period. Data between February 2013 and April 2024 were scanned. The databases were searched with the keywords 'pressure injury', 'nursing interventions' and 'open heart surgery'. The systematic compilation process was carried out in accordance with the guidelines in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guide. RESULTS: Seventeen studies were examined using nursing interventions that applied to the selected study population. Care packages included an inflatable head pad, a pressure sensor mattress cover, multi-layer silicone foam, pressure-reducing coatings, endotracheal tube (ETT) repositioning and cuff pressure regulation. Interventions to reduce PI in open heart surgery patients are applied in the preadmission, perioperative and postoperative periods. CONCLUSION: It was concluded that care packages, inflatable head pads, pressure sensor bedspreads, multi-layered silicone foam, pressure-reducing covers, ETT repositioning and cuff pressure regulation were effective in all nursing interventions. The strength of the available evidence was rated from strong to weak. RELEVANCE TO CLINICAL PRACTICE: These findings reveal an efficient combination of multi-component nursing interventions for preventing PIs in planning patient care in the intensive care. The interventions that are used throughout the patient's entire care process are crucial for the prevention of PIs.

12.
Ann Intensive Care ; 14(1): 105, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38963533

RESUMO

Infusion of fluids is one of the most common medical acts when resuscitating critically ill patients. However, fluids most often are given without consideration of how fluid infusion can actually improve tissue perfusion. Arthur Guyton's analysis of the circulation was based on how cardiac output is determined by the interaction of the factors determining the return of blood to the heart, i.e. venous return, and the factors that determine the output from the heart, i.e. pump function. His theoretical approach can be used to understand what fluids can and cannot do. In his graphical analysis, right atrial pressure (RAP) is at the center of this interaction and thus indicates the status of these two functions. Accordingly, trends in RAP and cardiac output (or a surrogate of cardiac output) can provide important guides for the cause of a hemodynamic deterioration, the potential role of fluids, the limits of their use, and when the fluid is given, the response to therapeutic interventions. Use of the trends in these values provide a physiologically grounded approach to clinical fluid management.

13.
J Neurosci Methods ; 409: 110217, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38964477

RESUMO

BACKGROUND: Parkinson's patients have significant autonomic dysfunction, early detect the disorder is a major challenge. To assess the autonomic function in the rat model of rotenone induced Parkinson's disease (PD), Blood pressure and ECG signal acquisition are very important. NEW METHOD: We used telemetry to record the electrocardiogram and blood pressure signals from awake rats, with linear and nonlinear analysis techniques calculate the heart rate variability (HRV) and blood pressure variability (BPV). we applied nonlinear analysis methods like sample entropy and detrended fluctuation analysis to analyze blood pressure signals. Particularly, this is the first attempt to apply nonlinear analysis to the blood pressure evaluate in rotenone induced PD model rat. RESULTS: HRV in the time and frequency domains indicated sympathetic-parasympathetic imbalance in PD model rats. Linear BPV analysis didn't reflect changes in vascular function and blood pressure regulation in PD model rats. Nonlinear analysis revealed differences in BPV, with lower sample entropy results and increased detrended fluctuation analysis results in the PD group rats. COMPARISON WITH EXISTING METHODS AND CONCLUSIONS: our experiments demonstrate the ability to evaluate autonomic dysfunction in models of Parkinson's disease by combining the analysis of BPV with HRV, consistent with autonomic impairment in PD patients. Nonlinear analysis by blood pressure signal may help in early detection of the PD. It indicates that the fluctuation of blood pressure in the rats in the rotenone model group tends to be regular and predictable, contributes to understand the PD pathophysiological mechanisms and to find strategies for early diagnosis.

14.
Sci Rep ; 14(1): 15407, 2024 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965251

RESUMO

The kidney and brain play critical roles in the regulation of blood pressure. Neuropeptide FF (NPFF), originally isolated from the bovine brain, has been suggested to contribute to the pathogenesis of hypertension. However, the roles of NPFF and its receptors, NPFF-R1 and NPFF-R2, in the regulation of blood pressure, via the kidney, are not known. In this study, we found that the transcripts and proteins of NPFF and its receptors, NPFF-R1 and NPFF-R2, were expressed in mouse and human renal proximal tubules (RPTs). In mouse RPT cells (RPTCs), NPFF, but not RF-amide-related peptide-2 (RFRP-2), decreased the forskolin-stimulated cAMP production in a concentration- and time-dependent manner. Furthermore, dopamine D1-like receptors colocalized and co-immunoprecipitated with NPFF-R1 and NPFF-R2 in human RPTCs. The increase in cAMP production in human RPTCs caused by fenoldopam, a D1-like receptor agonist, was attenuated by NPFF, indicating an antagonistic interaction between NPFF and D1-like receptors. The renal subcapsular infusion of NPFF in C57BL/6 mice decreased renal sodium excretion and increased blood pressure. The NPFF-mediated increase in blood pressure was prevented by RF-9, an antagonist of NPFF receptors. Taken together, our findings suggest that autocrine NPFF and its receptors in the kidney regulate blood pressure, but the mechanisms remain to be determined.


Assuntos
Comunicação Autócrina , Pressão Sanguínea , AMP Cíclico , Oligopeptídeos , Transdução de Sinais , Animais , Humanos , Camundongos , AMP Cíclico/metabolismo , Oligopeptídeos/farmacologia , Oligopeptídeos/metabolismo , Receptores de Neuropeptídeos/metabolismo , Túbulos Renais Proximais/metabolismo , Masculino , Rim/metabolismo , Camundongos Endogâmicos C57BL , Receptores de Dopamina D1/metabolismo
15.
BMC Anesthesiol ; 24(1): 221, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961365

RESUMO

BACKGROUND: This study aimed to evaluate the accuracy of ankle blood pressure measurements in relation to invasive blood pressure in the lateral position. METHODS: This prospective observational study included adult patients scheduled for elective non-cardiac surgery under general anesthesia in the lateral position. Paired radial artery invasive and ankle noninvasive blood pressure readings were recorded in the lateral position using GE Carescape B650 monitor. The primary outcome was the ability of ankle mean arterial pressure (MAP) to detect hypotension (MAP < 70 mmHg) using area under the receiver operating characteristic curve (AUC) analysis. The secondary outcomes were the ability of ankle systolic blood pressure (SBP) to detect hypertension (SBP > 140 mmHg) as well as bias (invasive measurement - noninvasive measurement), and agreement between the two methods using the Bland-Altman analysis. RESULTS: We analyzed 415 paired readings from 30 patients. The AUC (95% confidence interval [CI]) of ankle MAP for detecting hypotension was 0.88 (0.83-0.93). An ankle MAP of ≤ 86 mmHg had negative and positive predictive values (95% CI) of 99 (97-100)% and 21 (15-29)%, respectively, for detecting hypotension. The AUC (95% CI) of ankle SBP to detect hypertension was 0.83 (0.79-0.86) with negative and positive predictive values (95% CI) of 95 (92-97)% and 36 (26-46)%, respectively, at a cutoff value of > 144 mmHg. The mean bias between the two methods was - 12 ± 17, 3 ± 12, and - 1 ± 11 mmHg for the SBP, diastolic blood pressure, and MAP, respectively. CONCLUSION: In patients under general anesthesia in the lateral position, ankle blood pressure measurements are not interchangeable with the corresponding invasive measurements. However, an ankle MAP > 86 mmHg can exclude hypotension with 99% accuracy, and an ankle SBP < 144 mmHg can exclude hypertension with 95% accuracy.


Assuntos
Anestesia Geral , Tornozelo , Determinação da Pressão Arterial , Humanos , Feminino , Anestesia Geral/métodos , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Determinação da Pressão Arterial/métodos , Tornozelo/irrigação sanguínea , Idoso , Oscilometria/métodos , Pressão Sanguínea/fisiologia , Hipertensão/fisiopatologia , Hipertensão/diagnóstico , Hipotensão/diagnóstico , Hipotensão/fisiopatologia , Adulto , Posicionamento do Paciente/métodos
16.
J Tissue Viability ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38951049

RESUMO

AIM: To determine the relationship between the knowledge and self-efficiency regarding pressure ulcers of nursing students. METHODS: This descriptive and correlational study was conducted with 775 nursing students from three different universities in various regions of Turkey. The "Pressure Ulcer Knowledge Assessment Tool-Updated Version" and "Pressure Ulcer Management Self-Efficiency Scale for Nurses" tool were used to collect data between May and September 2023. The Strengthening the Reporting of Observational Studies checklist was followed to report this study. RESULTS: The mean knowledge score was 7.27 ± 3.09, and the mean self-efficiency on pressure ulcer management score was 35.5 ± 18.3. A statistically significant positive correlation was found between nursing students' knowledge and self-efficiency mean scores regarding pressure ulcers (p < 0.05). A significant difference was also found between the students' academic levels and gender and their knowledge and self-efficiency scores regarding pressure ulcers. CONCLUSION: In this study, where the data covers these three institutions, students' pressure ulcer knowledge and self-efficiency scores were lower compared to all academic years. Accordingly, it was also determined that students with more nursing practice experience showed higher knowledge and self-efficacy scores than students with less nursing practice experience. Additionally, the students' self-efficacy increased along with their knowledge level. Training courses may be suggested to improve students' knowledge and self-efficiency regarding pressure ulcers.

17.
Pediatr Cardiol ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38951145

RESUMO

After the Fontan procedure, patients require lifelong follow-up due to significant late morbidity and mortality. Thrombocytopenia is seen frequently post-Fontan, likely due to secondary hypersplenism from elevated Fontan pressure. We investigated platelet counts in patients with a Fontan circulation and assessed associations with catheterization data and clinical outcomes. This retrospective study included 92 patients (33% female) post-Fontan who had a complete blood count performed between January 2011 and July 2023. The age at evaluation was 24.0 ± 8.9 years. Outcomes measured included elevated Fontan pressure (≥ 15 mmHg), Fontan-associated liver disease (FALD), unscheduled admissions, transplant, and death. Participants with thrombocytopenia (≤ 150,000/µL) had significantly higher rates of elevated Fontan pressure (OR 8.1, 95% CI 1.3-52.7, p = 0.03), FALD (OR 4.1, 95% CI 1.6-10.6, p = 0.004), and unscheduled admissions (362 ± 577 versus 115 ± 185 admissions per 1000 patient-years, p = 0.02). Thrombocytopenia post-Fontan is associated with elevated Fontan pressure, FALD, and increased morbidity. Platelet count could serve as a non-invasive factor in identifying patients at risk of decompensation.

18.
Am J Hypertens ; 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38995194

RESUMO

BACKGROUND: Out-of-office blood pressure (BP) measurement is recommended when making a new hypertension diagnosis. In practice, however, hypertension is primarily diagnosed using clinic BP. The study objective was to understand patient attitudes about accuracy and patient-centeredness regarding hypertension diagnostic methods. METHODS: Qualitative study within a randomized controlled diagnostic study conducted between May 2017 and March 2019 comparing the accuracy and acceptability of BP measurement methods among patients in an integrated healthcare delivery system. All participants completed 24-hour ambulatory blood pressure monitoring (ABPM), plus either clinic BP, home BP monitoring (HBPM), or kiosk BP diagnostic testing. Qualitative interviewees (aged 31-76 years, n=35) were recruited from the main study. RESULTS: Participants who completed HBPM found it to be comfortable and low burden, and believed it produced accurate results. Participants in the clinic arm described clinic measurements as inconvenient. Participants in the kiosk arm overall did not favor kiosks due to concerns about accuracy and privacy. Participants described ABPM as the most accurate method due to repeated measurements over the 24-hour period in real-world contexts, but many found it uncomfortable and disruptive. Participants also noted methods that involved repeated measures such as HBPM and ABPM particularly influenced their understanding of whether or not they had hypertension. CONCLUSIONS: Hypertension diagnostic methods that include more BP measurements help patients gain a deeper understanding of BP variability and the lower reliability of infrequent measurements in clinic. These findings warrant implementing strategies to enhance out-office BP diagnostic testing in primary care.

19.
Psychophysiology ; : e14649, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38984813

RESUMO

Previous research suggested that exposure to long-lasting or repeated laboratory stressors may lead to rearrangement of cardiovascular control, with a shift of regulation mechanisms from dominant cardiac to dominant vascular influences between the early and late response phases, respectively. This study investigated whether similar rearrangement occurs during life stress accompanying chronic disease by analyzing also associations between cortisol level and cardiovascular variables in patients with fibromyalgia (FM). In 47 women with FM and 36 healthy women (HW), cardiovascular recordings were taken during active body posture changes (sitting, lying down, and standing). Moreover, hair cortisol concentration (HCC) was obtained. During standing, which involved orthostatic challenge, FM patients showed higher total peripheral resistance (TPR) but lower stroke volume (SV), cardiac output (CO), and baroreflex sensitivity than HW. During sitting and lying down, TPR was more closely associated with blood pressure (BP) than CO in FM patients; in contrast, CO was more closely associated with BP than TPR in HW. HCC correlated positively with TPR and BP in FM patients, but negatively with TPR and BP and positively with SV and CO in HW. Results suggest that chronic disease-related stress is associated with alterations in cardiovascular regulation toward greater involvement of vascular than cardiac mechanisms in BP control. Stress-related cortisol release may contribute to the long-term rearrangement of autonomic regulation. At the behavioral level, the dominance of vascular over cardiovascular control may relate to reduced somatic mobilization during an active fight-flight response in favor of passive and behaviorally immobile coping.

20.
Undersea Hyperb Med ; 51(2): 115-127, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38985148

RESUMO

For over five decades, many experimental and clinical studies have shown predominantly positive but controversial results on the efficacy of hyperbaric oxygen (HBO2) therapy in burns. The study aimed to define a common denominator or constellations, respectively, linked to the effects of HBO2 in burns with a special focus on dosage parameters. Based on original work since 1965, species, number of individuals, type of study, percentage of total body surface area (TBSA), region, depth of burn, causative agent, interval between burn and first HBO2 session, pressure, duration of individual session, number of HBO2 sessions per day, cumulative number of HBO2 sessions and type of chamber were assessed. Out of 47 publications included, 32 were animal trials, four were trials in human volunteers, and 11 were clinical studies. They contained 94 experiments whose features were processed for statistical evaluation. 64 (67.4%) showed a positive outcome, 16 (17.9%) an ambiguous one, and 14 (14.7%) a negative outcome. The only factor independently influencing the results was pressure with ATA (atmospheres absolute) lower than 3 ATA being significantly associated with better outcomes (p=0.0005). There is a dire need for well-designed clinical studies in burn centers equipped with hyperbaric facilities to establish dedicated treatment protocols.


Assuntos
Pressão Atmosférica , Queimaduras , Oxigenoterapia Hiperbárica , Oxigenoterapia Hiperbárica/métodos , Queimaduras/terapia , Humanos , Animais , Resultado do Tratamento , Ensaios Clínicos como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA