Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Exp Eye Res ; 241: 109818, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38422787

RESUMO

Down syndrome (DS) is the most common chromosomal disorder in humans. DS is associated with increased prevalence of several ocular sequelae, including characteristic blue-dot cerulean cataract. DS is accompanied by age-dependent accumulation of Alzheimer's disease (AD) amyloid-ß (Aß) peptides and amyloid pathology in the brain and comorbid early-onset Aß amyloidopathy and colocalizing cataracts in the lens. Quasi-elastic light scattering (QLS) is an established optical technique that noninvasively measures changes in protein size distributions in the human lens in vivo. In this cross-sectional study, lenticular QLS correlation time was decreased in adolescent subjects with DS compared to age-matched control subjects. Clinical QLS was consistent with alterations in relative particle hydrodynamic radius in lenses of adolescents with DS. These correlative results suggest that noninvasive QLS can be used to evaluate molecular changes in the lenses of individuals with DS.


Assuntos
Doença de Alzheimer , Catarata/congênito , Síndrome de Down , Cristalino , Humanos , Adolescente , Síndrome de Down/complicações , Síndrome de Down/patologia , Estudos Transversais , Doença de Alzheimer/metabolismo , Cristalino/metabolismo , Peptídeos beta-Amiloides/metabolismo
2.
Exp Eye Res ; 221: 108974, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35202705

RESUMO

Neuropathological hallmarks of Alzheimer's disease (AD) include pathogenic accumulation of amyloid-ß (Aß) peptides and age-dependent formation of amyloid plaques in the brain. AD-associated Aß neuropathology begins decades before onset of cognitive symptoms and slowly progresses over the course of the disease. We previously reported discovery of Aß deposition, ß-amyloidopathy, and co-localizing supranuclear cataracts (SNC) in lenses from people with AD, but not other neurodegenerative disorders or normal aging. We confirmed AD-associated Aß molecular pathology in the lens by immunohistopathology, amyloid histochemistry, immunoblot analysis, epitope mapping, immunogold electron microscopy, quantitative immunoassays, and tryptic digest mass spectrometry peptide sequencing. Ultrastructural analysis revealed that AD-associated Aß deposits in AD lenses localize as electron-dense microaggregates in the cytoplasm of supranuclear (deep cortex) fiber cells. These Aß microaggregates also contain αB-crystallin and scatter light, thus linking Aß pathology and SNC phenotype expression in the lenses of people with AD. Subsequent research identified Aß lens pathology as the molecular origin of the distinctive cataracts associated with Down syndrome (DS, trisomy 21), a chromosomal disorder invariantly associated with early-onset Aß accumulation and Aß amyloidopathy in the brain. Investigation of 1249 participants in the Framingham Eye Study found that AD-associated quantitative traits in brain and lens are co-heritable. Moreover, AD-associated lens traits preceded MRI brain traits and cognitive deficits by a decade or more and predicted future AD. A genome-wide association study of bivariate outcomes in the same subjects identified a new AD risk factor locus in the CTNND2 gene encoding δ-catenin, a protein that modulates Aß production in brain and lens. Here we report identification of AD-related human Aß (hAß) lens pathology and age-dependent SNC phenotype expression in the Tg2576 transgenic mouse model of AD. Tg2576 mice express Swedish mutant human amyloid precursor protein (APP-Swe), accumulate hAß peptides and amyloid pathology in the brain, and exhibit cognitive deficits that slowly progress with increasing age. We found that Tg2576 trangenic (Tg+) mice, but not non-transgenic (Tg-) control mice, also express human APP, accumulate hAß peptides, and develop hAß molecular and ultrastructural pathologies in the lens. Tg2576 Tg+ mice exhibit age-dependent Aß supranuclear lens opacification that recapitulates lens pathology and SNC phenotype expression in human AD. In addition, we detected hAß in conditioned medium from lens explant cultures prepared from Tg+ mice, but not Tg- control mice, a finding consistent with constitutive hAß generation in the lens. In vitro studies showed that hAß promoted mouse lens protein aggregation detected by quasi-elastic light scattering (QLS) spectroscopy. These results support mechanistic (genotype-phenotype) linkage between Aß pathology and AD-related phenotypes in lens and brain. Collectively, our findings identify Aß pathology as the shared molecular etiology of two age-dependent AD-related cataracts associated with two human diseases (AD, DS) and homologous murine cataracts in the Tg2576 transgenic mouse model of AD. These results represent the first evidence of AD-related Aß pathology outside the brain and point to lens Aß as an optically-accessible AD biomarker for early detection and longitudinal monitoring of this devastating neurodegenerative disease.


Assuntos
Doença de Alzheimer , Catarata , Doenças Neurodegenerativas , Doença de Alzheimer/genética , Peptídeos beta-Amiloides/metabolismo , Precursor de Proteína beta-Amiloide/metabolismo , Animais , Encéfalo/patologia , Catarata/patologia , Modelos Animais de Doenças , Estudo de Associação Genômica Ampla , Humanos , Camundongos , Camundongos Transgênicos , Doenças Neurodegenerativas/patologia
3.
Sensors (Basel) ; 19(11)2019 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-31159228

RESUMO

This research presents a microfermentor integrated into an optical fiber sensor based on quasi-elastic light scattering (QELS) to monitor and swiftly identify cellular growth kinetic parameters. The system uses a 1310 nm laser light that is guided through single-mode silica optical fibers to the interior of perfusion chambers, which are separated by polycarbonate membranes (470 nm pores) from microchannels, where a culture medium flows in a constant concentration. The system contains four layers, a superior and an inferior layer made of glass, and two intermediate poly(dimethylsiloxane) layers that contain the microchannels and the perfusion chambers, forming a reversible microfluidic device that requires only the sealing of the fibers to the inferior glass cover. The QELS autocorrelation decay rates of the optical signals were correlated to the cells counting in a microscope, and the application of this microsystem to the monitoring of alcoholic fermentation of Saccharomyces cerevisiae resulted in the kinetic parameters of KM = 4.1 g/L and µm = 0.49 h-1. These results agree with both the data reported in the literature and with the control batch test, showing that it is a reliable and efficient biological monitoring system.


Assuntos
Tecnologia de Fibra Óptica/métodos , Dimetilpolisiloxanos/química , Difusão Dinâmica da Luz/métodos , Fermentação/fisiologia , Membranas , Cimento de Policarboxilato/química , Saccharomyces cerevisiae/metabolismo
4.
Anal Bioanal Chem ; 408(15): 4003-10, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27000562

RESUMO

The size (hydrodynamic or Stokes radius, R H) of non-functionalized CdSeS/ZnS (core/shell) quantum dots (QDs) was characterized by size-exclusion chromatography with on-line quasi-elastic light scattering (SEC/QELS). Accurate determination of the size of QDs is important, because many of the optical properties of these materials are size dependent. A clear advantage of SEC/QELS over many batch techniques (e.g., QELS without separation) is the capability of the hyphenated technique to characterize the entire size range of a disperse sample, rather than merely providing a statistical average of the sizes present. Here, the SEC/QELS-determined R H values of CdSeS/ZnS QDs are compared to those determined by a traditional SEC experiment employing a calibration curve based on polystyrene standards, providing for the first reported study on SEC/QELS of non-functionalized QDs while also demonstrating the shortcomings of the widely-employed calibration curve approach. Furthermore, combining the R H of the QDs obtained by SEC/QELS with core size measurements derived from transmission electron microscopy allowed further calculation of the size of the QDs' coronas. The latter result was found to be in close agreement to the previously measured dimension of the main corona constituent, as well as with the calculated size of this constituent.

5.
Rom J Ophthalmol ; 60(2): 79-89, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-29450328

RESUMO

PURPOSE: Photon-correlation spectroscopy (PCS) (quasi-elastic light scattering spectroscopy, dynamic light scattering spectroscopy) allows the non-invasively reveal of local dynamics and local heterogeneities of macromolecular systems. The capability of this technique to diagnose the retinal pathologies by in-vivo investigations of spatial anomalies of retinas displaying non-exudative senile macular degeneration was evaluated. Further, the potential use of the technique for the diagnosis of the macular degeneration was analyzed and displayed by the Receiver Operating Curve (ROC). METHODS: The maculae and the peripheral retina of 73 normal eyes and of 26 eyes afflicted by an early stage of non-exudative senile macular degeneration were characterized by time-correlation functions and analyzed in terms of characteristic decay times and apparent size distributions. RESULTS: The characteristics of the obtained time-correlation functions of the eyes afflicted with nonexudative macular degeneration and of normal eyes differed significantly, which could be referred to a significant change of the nano- and microstructure of the investigated pathologic maculas. CONCLUSIONS: Photon-correlation spectroscopy is able to assess the macromolecular and microstructural aberrations in the macula afflicted by non-exudative, senile macular degeneration. It has been demonstrated that macromolecules of this disease show a characteristic abnormal behavior in the macula.


Assuntos
Difusão Dinâmica da Luz , Atrofia Geográfica/diagnóstico , Análise Espectral/métodos , Idoso , Feminino , Humanos , Macula Lutea , Masculino , Pessoa de Meia-Idade , Curva ROC , Acuidade Visual
6.
Anal Chim Acta ; 886: 207-13, 2015 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-26320655

RESUMO

The analysis of natural and otherwise complex samples is challenging and yields uncertainty about the accuracy and precision of measurements. Here we present a practical tool to assess relative accuracy among separation protocols for techniques using light scattering detection. Due to the highly non-linear relationship between particle size and the intensity of scattered light, a few large particles may obfuscate greater numbers of small particles. Therefore, insufficiently separated mixtures may result in an overestimate of the average measured particle size. Complete separation of complex samples is needed to mitigate this challenge. A separation protocol can be considered improved if the average measured size is smaller than a previous separation protocol. Further, the protocol resulting in the smallest average measured particle size yields the best separation among those explored. If the differential in average measured size between protocols is less than the measurement uncertainty, then the selected protocols are of equivalent precision. As a demonstration, this assessment metric is applied to optimization of cross flow (V(x)) protocols in asymmetric flow field flow fractionation (AF(4)) separation interfaced with online quasi-elastic light scattering (QELS) detection using mixtures of polystyrene beads spanning a large size range. Using this assessment metric, the V(x) parameter was modulated to improve separation until the average measured size of the mixture was in statistical agreement with the calculated average size of particles in the mixture. While we demonstrate this metric by improving AF(4) V(x) protocols, it can be applied to any given separation parameters for separation techniques that employ dynamic light scattering detectors.


Assuntos
Nanopartículas/química , Poliestirenos/química , Fracionamento por Campo e Fluxo , Luz , Tamanho da Partícula , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA