Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.081
Filtrar
1.
Clin Ophthalmol ; 18: 2545-2553, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39257591

RESUMO

Purpose: We evaluated the effect of optimization of the intraocular lens (IOL) power calculation formula SRK/T and Barrett Universal II (BU II) in long eyes (≥26 mm: group L) and short eyes (≤22 mm: group S) using axial length calculated from segmented refractive indices (SRI). Setting: Multicenter study at five sites in Japan. Design: Retrospective observational study. Methods: This study included 461 eyes of 461 patients (mean age 73.8 ± 8.4 years) who underwent cataract surgery. The predicted refractive error (PRE) was compared between the SRI (ARGOS) and the equivalent refractive index (ERI) biometers (IOLMasterTM700). The patients were randomly divided into two groups, a learning group and a validation group. The optimization constants were determined in the learning group, and the optimization constants were subsequently applied to the validation group and compared with the ERI biometer results. Results: Using both SRK/T and BU II, the validation group's PRE using optimization constants for the SRI biometer in group L was significantly smaller than that using the ERI biometer (p<0.001, p<0.01). In group L, the arithmetic PRE of Barrett UII formula with SRI showed a significant improvement after optimization compared to before optimization (p<0.0001). In group S, the arithmetic PRE of SRK/T and Barrett UII formula with SRI showed a significant improvement (p<0.0001, p<0.0001). Conclusion: In long and short eyes, the current study revealed that optimization of the SRK/T and Barrett formula constants for the SRI biometer was beneficial to achieve accurate refractive outcomes after cataract surgery.

2.
Food Sci Biotechnol ; 33(13): 2971-2978, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39220306

RESUMO

In this study, xylitol, a common sweetener and sucrose substitute in low-calorie foods, was quantified by high-performance liquid chromatography (HPLC). During the establishment of the analytical method, three representative detection approaches, ultraviolet detector (UVD), evaporative light scattering detector, and refractive index detector, were compared and applied to determine the xylitol content in various foods distributed in Korea. The results were compared for method validation, measurement uncertainty, and applicability. As a result, HPLC-UVD showed the lowest limit of detection (0.01 mg/L) and limit of quantification (0.04 mg/L) among the three methods. It showed a low range of relative expanded uncertainty (1.12-3.98%) and could quantify xylitol in the wide range of the samples, even trace amounts of xylitol. Therefore, a total of 160 food items, including chewing gum, candy, beverage, tea, other processed products, and beverage base, were applied with three replicates by the proposed HPLC-UVD method.

3.
Adv Sci (Weinh) ; : e2403143, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39225343

RESUMO

Measurements of the refractive index of liquids are in high demand in numerous fields such as agriculture, food and beverages, and medicine. However, conventional ellipsometric refractive index measurements are too expensive and labor-intensive for consumer devices, while Abbe refractometry is limited to the measurement at a single wavelength. Here, a new approach is proposed using machine learning to unlock the potential of colorimetric metasurfaces for the real-time measurement of the dispersive refractive index of liquids over the entire visible spectrum. The platform with a proof-of-concept experiment for measuring the concentration of glucose is further demonstrated, which holds a profound impact in non-invasive medical sensing. High-index-dielectric metasurfaces are designed and fabricated, while their experimentally measured reflectance and reflected colors, through microscopy and a standard smartphone, are used to train deep-learning models to provide measurements of the dispersive background refractive index with a resolution of ≈10-4, which is comparable to the known index as measured with ellipsometry. These results show the potential of enabling the unique optical properties of metasurfaces with machine learning to create a platform for the quick, simple, and high-resolution measurement of the dispersive refractive index of liquids, without the need for highly specialized experts and optical procedures.

4.
Adv Mater ; : e2408060, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39087402

RESUMO

Organic crystals are widely used by animals to manipulate light for producing structural colors and for improving vision. To date only seven crystal types are known to be used, and among them ß-guanine crystals are by far the most widespread. The fact that almost all these crystals have unusually high refractive indices (RIs) is consistent with their light manipulation function. Here, the physical, structural, and optical principles of how light interacts with the polarizable free-electron-rich environment of these quasiaromatic molecules are addressed. How the organization of these molecules into crystalline arrays introduces optical anisotropy and finally how organisms control crystal morphology and superstructural organization to optimize functions in light reflection and scattering are also discussed. Many open questions remain in this fascinating field, some of which arise out of this in-depth analysis of the interaction of light with crystal arrays. More types of organic crystals will probably be discovered, as well as other organisms that use these crystals to manipulate light. The insights gained from biological systems can also be harnessed for improving synthetic light-manipulating materials.

5.
Sci Rep ; 14(1): 18637, 2024 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-39128906

RESUMO

Fiber optic localized surface plasmon resonance (LSPR) sensors have become an effective tool in refractive index (RI) detection for biomedical applications because of their high sensitivity. However, using conventional optical fiber has caused limitations in implanting the sensor in the body. This research presents the design and construction of a new type of polymer-based LSPR sensors to address this issue. Also, finite element method (FEM) is used to design the sensor and test it theoretically. The proposed polymer optical fiber (POF) based on citrate is biocompatible, flexible, and degradable, with a rate of 22% and 27 over 12 days. The step RI structure utilizes two polymers for light transmission: poly (octamethylene maleate citrate) (POMC) as the core and poly (octamethylene citrate) (POC) as the cladding. The POF core and cladding diameters and lengths are 700 µm, 1400 µm, and 7 cm, respectively. The coupling efficiency of light to the POF was enhanced using a microsphere fiber optic tip. The obtained results show that the light coupling efficiency increased to 77.8%. Plasma surface treatment was used to immobilize gold nanoparticles (AuNPs) on the tip of the POF, as a LSPR-POF sensor. Adsorption kinetics was measured based on the pseudo-first-order model to determine the efficiency of immobilizing AuNPs, in which the adsorption rate constant (k) was obtained be 8.6 × 10-3 min-1. The RI sensitivity of the sensor in the range from 1.3332 to 1.3604 RIU was obtained as 7778%/RIU, and the sensitivity was enhanced ~ 5 times to the previous RI POF sensors. These results are in good agreement with theory and computer simulation. It promises a highly sensitive and label-free detection biosensor for point-of-care applications such as neurosciences.

6.
Sensors (Basel) ; 24(15)2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39123904

RESUMO

In this paper we derived an expression that allows the determination of the thermo-optic coefficient of weakly-guiding germanium-doped silica fibers, based on the thermal behavior of optical fiber devices, such as, fiber Bragg gratings (FBGs). The calculations rely on the full knowledge of the fiber parameters and on the temperature sensitivity of FBGs. In order to validate the results, we estimated the thermo-optic coefficient of bulk GeO2 glass at 293 K and 1.55 µm to be 18.3 × 10-6 K-1. The determination of this value required to calculate a correction factor which is based on the knowledge of the thermal expansion coefficient of the fiber core, the Pockels' coefficients (p11 = 0.125, p12 = 0.258 and p44 = -0.0662) and the Poisson ratio (ν = 0.161) of the SMF-28 fiber. To achieve that goal, we estimated the temperature dependence of the thermal expansion coefficient of GeO2 and we discussed the dispersion and temperature dependence of Pockels' coefficients. We have presented expressions for the dependence of the longitudinal and transverse acoustic velocities on the GeO2 concentration used to calculate the Poisson ratio. We have also discussed the dispersion of the photoelastic constant. An estimate for the temperature dependence of the thermo-optic coefficient of bulk GeO2 glass is presented for the 200-300 K temperature range.

7.
Materials (Basel) ; 17(15)2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39124381

RESUMO

The thermal and optical properties of 60TeO2-20K2TeO3-10WO3-10Nb2O5 (in mol%) glasses doped with Ho2O3, Er2O3, and Tm2O3 were explored in the present work. The thermal stability, refractive index n, extinction coefficient k, absorption coefficient α, and optical band gap of the glasses were evaluated. The UV-Vis-NIR absorption spectra, the Judd-Ofelt intensity parameter, the spectroscopic quality factor, and the emission and absorption cross-sections were calculated to investigate the effects of Er3+ and Tm3+, respectively, on the band spectroscopic properties of Ho3+ ions. The results showed that the maximum emission cross-section was approximately 8×10-21 cm2, and the values of the full width at half maximum (FWHM), quality factor (σe×FWHM), and gain coefficient of Ho3+: 5I7→5I8 were also reported. The value of the FWHM×σe was 1200×10-28 cm3, which showed greater gain characteristics than earlier study results. For 2 µm mid-infrared solid-state lasers, the glasses that were examined might be a good host material.

8.
Heliyon ; 10(15): e35438, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39170339

RESUMO

The solvation behavior of protein is an important factor in protein-based food products. In the present study, the xylitol (XY) - ovalbumin (OVN) interaction in an aqueous solution of different pH conditions is analyzed in two methods. In one method, the thermodynamic parameters Gibbs free energy, free volume, and internal pressure are calculated by using ultrasonic velocity, density, and viscosity in addition the refractive index is also measured. The second method is a theoretical method in which using the Laplace transform technique the diffused amount of protein have been calculated for OVN with and without XY in different pH environment. The addition of XY with OVN makes the system with more free energy and free volume as the internal pressure decreases. This trend shows that preferential interaction occurs between solvent-solute molecules. The diffusivity of OVN is reduced after the addition of XY representing the strength of protein-protein interaction. The effect of pH changes is well reflected in both experimental and theoretical results. The results confirm that acidic pH extremity offers more solvation of OVN compared to alkaline pH extremity.

9.
Sci Rep ; 14(1): 20182, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39215073

RESUMO

Herein, we investigated the distinctive scattering properties exhibited by single gold nanorods coated with palladium (AuNRs@Pd), with variations in the Pd shell thicknesses and morphologies. AuNRs@Pd were synthesized through bottom-up epitaxial Pd growth using two different concentrations of Pd precursor. These single AuNRs@Pd displayed the characteristic of subradiant and superradiant localized surface plasmon resonance peaks, characterized by a noticeable gap marked by a Fano dip. We revealed the effect of local refractive index (RI) on the subradiant and superradiant peak energies, as well as the Fano dip in the scattering spectra of AuNRs@Pd with different Pd shell thicknesses. We demonstrated the applicability of the inflection points (IFs) method on detecting peaks and dip changes across different RIs. Thin AuNRs@Pd1mM displayed more pronounced sensitivity to peak shifts in response to variations in local RIs compared to thick AuNRs@Pd2mM. In contrast, thick AuNRs@Pd2mM exhibited greater sensitivity to changes in curvature near the subradiant and superradiant peak energies rather than peak shift sensitivity across different local RIs. Moreover, the Fano dip shift was more noticeable in thick AuNRs@Pd2mM compared to thin AuNRs@Pd1mM across different local RIs. Therefore, we provided new insight into the RI sensitivity on subradiant, superradiant, and Fano resonance modes in single AuNRs@Pd.

10.
Micromachines (Basel) ; 15(8)2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39203637

RESUMO

This paper introduces a novel plasmon refractive index nanosensor structure based on Fano resonance. The structure comprises a metal-insulator-metal (MIM) waveguide with an inverted rectangular cavity and a circle minus a small internal circle plus a rectangular cavity (CMSICPRC). This study employs the finite element method (FEM) to analyze the sensing characteristics of the structure. The results demonstrate that the geometrical parameters of specific structures exert a considerable influence on the sensing characteristics. Simulated experimental data show that the maximum sensitivity of this structure is 3240 nm/RIU, with a figure of merit (FOM) of 52.25. Additionally, the sensor can be used in biology, for example, to detect the concentration of hemoglobin in blood. The sensitivity of the sensor in this application, according to our calculations, can be 0.82 nm∙g/L.

11.
Sensors (Basel) ; 24(16)2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39204778

RESUMO

The article is dedicated to measuring the thickness of step height standards using the author's version of the variable wavelength interferometer (VAWI) in the reflected-light mode, where the interference pattern is created by the combination of two Wollaston prisms. The element of novelty consists in replacing the traditional search for the coincidence of fringes in the object and background with a continuous measurement of their periods and phases relative to the zero-order fringe. The resulting system of sinusoids is then analyzed using two methods: the classical one and the second utilizing the criterion of uniform thickness. The theory is followed by simulation and experimental parts, providing insight to the metrological potential of the VAWI technology.

12.
Adv Mater ; : e2405650, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39169743

RESUMO

Plasmonic nanoparticles can be assembled into a superlattice, to form optical metamaterials, particularly targeting precise control of optical properties such as refractive index (RI). The superlattices exhibit enhanced near-field, given the sufficiently narrow gap between nanoparticles supporting multiple plasmonic resonance modes only realized in proximal environments. Herein, the planar superlattice of plasmonic Au nanohexagons (AuNHs) with precisely controlled geometries such as size, shape, and edge-gaps is reported. The proximal AuNHs superlattice realized over a large area with selective edge-to-edge assembly exhibited the highest-ever-recorded RI values in the near-infrared (NIR) band, surpassing the upper limit of the RI of the natural intrinsic materials (up to 10.04 at λ = 1.5 µm). The exceptionally enhanced RI is derived from intensified in-plane surface plasmon coupling across the superlattices. Precise control of the edge-gap of neighboring AuNHs systematically tuned the RI as confirmed by numerical analysis based on the plasmonic percolation model. Furthermore, a 1D photonic crystal, composed of alternating layers of AuNHs superlattices and low-index polymers, is constructed to enhance the selectivity of the reflectivity operating in the NIR band. It is expected that the proximal AuNHs superlattices can be used as new optical metamaterials that can be extended to the NIR range.

13.
Spectrochim Acta A Mol Biomol Spectrosc ; 324: 124964, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39180972

RESUMO

In this work, we study the contributions that different molecular blocks have in the wavelength-dependence of the refractive index in ionic liquids. The ionic liquids chosen for this work are combinations of the bis(trifluoromethylsulfonyl)imide anion with cations based on four different heterocycles with different extents of charge delocalization. The analysis is performed in terms of the experimental electronic polarizability, which is obtained by combining measurements of refractive index curves and densities via the Lorentz-Lorenz equation. Exploiting the additivity of electronic polarizability in ionic liquids, the contribution of the anion and the heterocycles of the cations is separated from that of the alkyl chains. Our results show important differences in these contributions, revealing a key influence of the charge delocalization in the cationic rings on the behavior of the refractive index dispersion. The understanding of how different parts of ionic liquids affect their refractive index dependence on wavelength would allow to gain precise control of this magnitude, enabling the development of customized optical materials for diverse applications in photonics and sensing technologies.

14.
Materials (Basel) ; 17(14)2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39063721

RESUMO

CrSBr is a recently discovered two-dimensional anti-ferromagnet. It has attracted much attention due to its superior properties for potential optoelectronic and spintronic applications. However, its complex refractive index with layer dependence has not been systematically studied yet. In this work, we studied the room-temperature complex refractive indices of thin CrSBr flakes of different thicknesses in the visible light range. Using micro-reflectance spectroscopy, we measured the optical contrast of thin CrSBr flakes with respect to different substrates. The complex refractive index was extracted by modeling the optical contrast with the Fresnel equations. We extracted the band gap values of CrSBr in the few-layer limit. We determined the band gaps for monolayer, bilayer, and trilayer CrSBr to be 1.88 eV, 1.81 eV, and 1.77 eV, respectively. As a comparison, the band gap for multilayer CrSBr is outside our measured range, that is, below 1.55 eV. Our results suggest that the band gap of CrSBr decreases as thickness increases.

15.
Micromachines (Basel) ; 15(7)2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-39064403

RESUMO

Currently, coating with anti-reflective materials is an attractive approach to improve the quality of screen-based displays. In this study, mesoporous silica particles were systematically synthesized as a function of surfactant (i.e., CTAC-cetyltrimethylammonium chloride) concentration to serve as main coating fillers possessing low refractive indices. Precisely changing the amount of the CTAC surfactant, silica sol with an average diameter of 50 nm exhibits distinctively different specific surface areas, pore size, and pore volume. Prior to the preparation of final coating solutions containing these silica particle fillers, the percentage of solid content was optimized on a glass slide. The use of 50 wt% solid content exhibited the highest transmittance of light. Among various content levels of silica sol, the use of 3.5 wt% of silica particles in the solid content displayed the highest transmittance (i.e., best anti-reflectiveness). Under the almost identical coating layers prepared with the fixed amount of silica particles possessing different surface areas, pore size, and pore volume, it appears that the largest pore volume played the most important role in improving the anti-reflective properties. Experimentally understanding the key feature of low-refractive filler materials under the optimized conditions could provide a clear view to develop highly effective anti-reflective materials for various display applications.

16.
Medicina (Kaunas) ; 60(7)2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-39064485

RESUMO

Background and Objectives: To compare the biometry of eyes obtained with two swept-source optical coherence tomography-based biometers-Argos (A), using an individual refractive index, and IOLMaster 700 (IM), using an equivalent refractive index-for all structures. Materials and Methods: The biometry of 105 eyes of 105 patients before cataracts were analyzed in this study. Parameters such as axial length (AL), anterior chamber depth (ACD), and lens thickness (LT) were compared from both devices. According to the axial length measurements, patients were divided into three groups, as follows: group 1-short eyes (AL < 22.5 mm), group 2-average eyes (22.5 ≤ AL ≤ 26.0 mm), and group 3-long eyes (AL > 26.0 mm). Results: The correlation coefficiency among all compared parameters varies from R = 0.92 to R = 1.00, indicating excellent reliability of IM and A. A statistical significance in axial length was indicated in the group of short eyes (n = 26)-mean AL (A) 21.90 mm (±0.59 mm) vs. AL (IM) 21.8 mm ± (0.61 mm) (p < 0.001)-and in the group of long eyes (n = 5)-mean AL (A) 27.95 mm (±2.62 mm) vs. mean AL (IM) 28.10 mm (±2.64) (p < 0.05). In the group of average eyes (n = 74), outcomes were similar-mean AL (A) 23.56 mm (±0.70 mm) vs. mean AL (IM) 23,56 mm (±0.71 mm) (p > 0.05). The anterior chamber depth measurements were higher when obtained with Argos than with IOLMaster 700-mean ACD (A) 3.06 mm (±0.48 mm) vs. mean ACD (IM) 2.92 mm (±0.46) p < 0.001. There was no statistical significance in mean LT-mean LT (A) 4.75 mm (±0.46 mm) vs. mean LT (IM) 4.72 mm (±0.44 mm) (p = 0.054). The biometry of one eye with dense cataracts could be measured only with Argos, using the Enhanced Retinal Visualization mode. Conclusions: Axial length measurements from both devices were different in the groups of short and long eyes, but were comparable in the group of average eyes. The anterior chamber depth values obtained with Argos were higher than the measurements acquired with IOLMaster 700. These differences may be particularly important when selecting IOLs for patients with extreme AL values.


Assuntos
Biometria , Catarata , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Biometria/métodos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Comprimento Axial do Olho/diagnóstico por imagem , Reprodutibilidade dos Testes , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/anatomia & histologia , Idoso de 80 Anos ou mais
17.
Sensors (Basel) ; 24(14)2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39065875

RESUMO

Hematite (α-Fe2O3) is widely used in sensor sensitization due to its excellent optical properties. In this study, we present a sensitivity-enhanced surface plasmon resonance alcohol sensor based on Fe2O3/Au. We describe the fabrication process of the sensor and characterize its structure. We conduct performance testing on sensors coated multiple times and use solutions with the same gradient of refractive indices as the sensing medium. Within the refractive index range of 1.3335-1.3635, the sensor that was coated twice achieved the highest sensitivity, reaching 2933.2 nm/RIU. This represents a 30.26% enhancement in sensitivity compared to a sensor with a pure gold monolayer film structure. Additionally, we demonstrated the application of this sensor in alcohol concentration detection by testing the alcohol content of common beverages, showing excellent agreement with theoretical values and highlighting the sensor's potential in food testing.

18.
Sensors (Basel) ; 24(14)2024 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-39065961

RESUMO

The seawater refractive index is an essential parameter in ocean observation, making its high-precision measurement necessary. This can be effectively achieved using a position-sensitive detector-based measurement system. However, in the actual measurement process, the impact of the jitter signal measurement error on the results cannot be ignored. In this study, we theoretically analysed the causes of long jitter signals during seawater refractive index measurements and quantified the influencing factors. Through this analysis, it can be seen that the angle between the two windows in the seawater refractive index measurement area caused a large error in the results, which could be effectively reduced by controlling the angle to within 2.06°. At the same time, the factors affecting the position-sensitive detector's measurement accuracy were analysed, with changes to the background light, the photosensitive surface's size, and the working environment's temperature leading to its reduction. To address the above factors, we first added a 0.9 nm bandwidth, narrow-band filter in front of the detector's photosensitive surface during system construction to filter out any light other than that from the signal light source. To ensure the seawater refractive index's measuring range, a position-sensitive detector with a photosensitive surface size of 4 mm × 4 mm was selected; whereas, to reduce the working environment's temperature variation, we partitioned the measurement system. To validate the testing error range of the optimised test system, standard seawater samples were measured under the same conditions, showing a reduction in the measurement system's jitter signal from 0.0022 mm to 0.0011 mm, before and after optimisation, respectively, as well as a reduction in the refractive index's deviation. The experimental results show that the refractive index of seawater was effectively reduced by adjusting the measurement system's optical path and structure.

19.
Forensic Sci Int ; 361: 112124, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38971140

RESUMO

Latent fingerprints (LFPs) are predominantly used for personal identification, but in recent years research has shown their potential for drug screening. Despite this there is no standardised collection method to allow accurate drug test interpretation. We sought to help address this by characterising different variables related to sweat deposition in LFPs as the knowledge is limited. A series of experiments were conducted firstly to validate a novel tool called the Ridgeway (Intelligent Fingerprint Ltd. UK) to quantify the amount of sweat deposited from a LFP using the refractive index (RI). A significant positive correlation was observed between the Ridgeway score (Rs) and LFP mass [r = 0.868, p < 0.01]. The Rs was used as means to investigate optimal sampling to characterise sample deposition for drug screening purposes. It was found with a consistent disposition pressure (300 - 400 g) and surface (glass slide) no significant difference was observed between the left and right index finger [left: p = 0.938; right: p = 0.838]. Significantly higher Rs [p<0.01] were obtained when 10 cumulative LFPs were deposited compared to a single LFP, suggesting a larger sweat quantity. We also wanted to investigate optimal eccrine sweat sampling to confirm drug ingestion over drug contamination of the fingerprint. We found that wearing gloves did not significantly improve mean difference in Rs when compared to no gloves [p = 0.239]. To produce eccrine only LFPs, external contamination (e.g. sebaceous sweat) needs to be removed. Soap with lint free tissue was significantly better for this compared to antibacterial hand gel [p<0.01]. Our findings showed that the Ridgeway tool effectively quantified LFPs at the point of deposition using a refractive index and enabled us to establish conditions for consistent LFP sampling.


Assuntos
Dermatoglifia , Refratometria , Suor , Humanos , Suor/química , Masculino , Feminino , Adulto , Glândulas Écrinas , Detecção do Abuso de Substâncias/métodos , Luvas Protetoras
20.
J Mol Model ; 30(8): 240, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38954155

RESUMO

CONTEXT: In this study, we evaluate the geometrical, absorption, optoelectronic, electronic, nonlinear optical (NLO) and thermodynamic properties of dibenzo[b,def]chrysene molecule derivatives by means of DFT and TD-DFT simulations. In view of the aim of producing new high-performance materials for non-linear optics (NLO) by doping test, two types of doping were used. We obtained six derivatives by doping with organic dopants (Nitro, amide and ticyanoethenyl) and mixed alkali metal (potassium) and organic dopants. Doping with organic dopants produced molecules A, B and C, respectively when substituting one hydrogen with nitro (NO2), amide (CONH2) and tricyanoethenyl (C5N3) groups, while mixed doping involved considering A, B and C and then substituting two hydrogens with two potassiums to obtain compounds D, E and F respectively. The negative values of the various interaction energies calculated for all the doped molecules show that they are all stable, but also that molecules C and F are the most stable in the case of both dopings. The gap energies calculated at the B3LYP level of theory are all below 3 eV, which means that all the molecules obtained are semiconductors. Better still, compounds C and F, with gap energies of 1.852 eV and 1.204 eV, respectively, corresponding to decreases of 35.67% and 58.18% in gap energy compared with the pristine molecule, are more reactive than the other doped molecules. Mixed doping is therefore a highly effective way of narrowing the energy gap and boosting the semiconducting character and reactivity of organic materials. Optoelectronic properties have also been improved, with refractive index values higher than those of the reference material, glass. This shows that our compounds could be used under very high electric field conditions of the order of 4.164 × 109 V.m-1 for C and 7.410 × 109 V.m-1 for F the highest values at the B3LYP level of theory. The maximum first-order hyperpolarizability values for both types of doping are obtained at the CAM-B3LYP level of theory by C: ß mol = 92.088 × 10-30esu and by F: ß mol = 129.449 × 10-30esu, and second-order values are also given by these same compounds. These values are higher than the reference value, which is urea, making our compounds potential candidates for high-performance NLO applications. In dynamic mode and at a frequency of 1064 nm, at the CAM-B3LYP level of theory, the highest dynamic hyperpolarizability coefficients were obtained by C and F. Hyper-Rayleigh scattering ß HRS , coefficients of the electro-optical Pockel effect (EOPE), EFISHG, third-order NLO-response degree four-wave mixing γ DFWM , quadratic nonlinear refractive index n2 were also calculated. The maximum values of n2 are obtained by C (6.13 × 10-20 m2/W) and F (6.60 × 10-20 m2/W), these values are 2.24 times higher than that of fused silica which is the reference for degenerate four-wave mixing so our molecules could also have applications in optoelectronics as wavelength converters, optical pulse modulators and optical switches. METHODS: Using the DFT method, we were able to determine the optimized and stable electronic structures of doped dibenzo[b,def]chrysene derivatives in the gas phase. We limited ourselves to using the proven B3LYP and CAMB3LYP levels of theory for calculating electronic properties, and non-linear optics with the 6-311G + + (d,p) basis set, which is a large basis set frequently used for these types of compound. Gaussian 09 software was used to run our calculations, and Gauss View 6.0.16 was used to visualize the output files. TD-DFT was also used to determine absorption properties at the B3LYP level of theory, using the same basis set.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA