Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Clin Chim Acta ; : 119951, 2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39216815

RESUMO

OBJECTIVES: The COVID-19 pandemic poses ongoing challenges to global public health systems, emphasizing the critical necessity for efficient diagnostic and prognostic markers. This study evaluates the MAGLUMI® SARS-CoV-2 Ag N protein chemiluminescent immunoassay (MAG-CLIA) for its analytical performance and its role in predicting disease severity and prognosis among severe COVID-19 patients with comorbidities. METHODS: Analytical validation of plasma MAG-CLIA SARS-CoV-2 Ag N protein encompassed precision, interference, LoQ and linearity. Plasma N protein concentrations and other biomarkers were measured within 48 h of admission, tracked until discharge or death. The Mann-Whitney U test explored the association between plasma N protein and COVID-19 severity or prognosis. Longitudinal monitoring of plasma N protein dynamics was conducted in representative patients. RESULTS: MAG-CLIA demonstrated precise quantification of plasma N protein with a CV below 10 % and minimal interference. The LoQ was 0.88 ng/L, with a broad linear range. Plasma N protein showed high diagnostic accuracy for COVID-19, achieving 95.42 % specificity and 78.32 % sensitivity at 2.388 ng/L. Plasma N protein emerged as a valuable prognostic indicator, correlating with mechanical ventilation need and patient survival. Plasma N protein concentrations ≥ 424.3 ng/L (AUC 0.8102, sensitivity 78.38 %, specificity 85.48 %) were associated with poor prognosis in severe COVID-19 patients with comorbidities. CONCLUSIONS: MAG-CLIA's SARS-CoV-2 N protein detection in plasma demonstrates both analytical reliability and clinical relevance in our inaugural evaluation. As a promising prognostic biomarker for severe COVID-19 patients, it offers crucial insights into disease severity and progression, emphasizing the significance of early monitoring and intervention, especially for patients with comorbidities.

2.
Int J Mol Sci ; 25(16)2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39201259

RESUMO

The strong immunogenicity of the SARS-CoV-2 nucleocapsid protein is widely recognized, and the detection of specific antibodies is critical for COVID-19 diagnostics in patients. This research proposed direct, label-free, and sensitive detection of antibodies against the SARS-CoV-2 nucleocapsid protein (anti-SCoV2-rN). Recombinant SARS-CoV-2 nucleocapsid protein (SCoV2-rN) was immobilized by carbodiimide chemistry on an SPR sensor chip coated with a self-assembled monolayer of 11-mercaptoundecanoic acid. When immobilized under optimal conditions, a SCoV2-rN surface mass concentration of 3.61 ± 0.52 ng/mm2 was achieved, maximizing the effectiveness of the immunosensor for the anti-SCoV2-rN determination. The calculated KD value of 6.49 × 10-8 ± 5.3 × 10-9 M confirmed the good affinity of the used monoclonal anti-SCoV2-rN antibodies. The linear range of the developed immunosensor was from 0.5 to 50 nM of anti-SCoV2-rN, where the limit of detection and the limit of quantification values were 0.057 and 0.19 nM, respectively. The immunosensor exhibited good reproducibility and specificity. In addition, the developed immunosensor is suitable for multiple anti-SCoV2-rN antibody detections.


Assuntos
Anticorpos Antivirais , COVID-19 , Proteínas do Nucleocapsídeo de Coronavírus , SARS-CoV-2 , Ressonância de Plasmônio de Superfície , SARS-CoV-2/imunologia , Ressonância de Plasmônio de Superfície/métodos , Humanos , Anticorpos Antivirais/imunologia , COVID-19/diagnóstico , COVID-19/imunologia , COVID-19/virologia , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Imunoensaio/métodos , Técnicas Biossensoriais/métodos , Fosfoproteínas/imunologia , Fosfoproteínas/química , Limite de Detecção
3.
Vaccine X ; 19: 100518, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39040888

RESUMO

Background: Our investigation focused whether infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) before or after receiving the mRNA COVID-19 vaccine can increase immune protection. And we also investigated relationship of infection acquired. Methods: Three shots of the mRNA coronavirus disease 2019 (COVID-19) vaccine BNT162b2 were administered to 736 healthcare workers at Tokyo Shinagawa Hospital. Serum samples were collected before the first shot (P1), at one month (P2), and at six months (P3) after the second shot and at one month after the third shot (P4). The presence of infection was assessed using IgG against the nucleocapsid (IgG (N) and RBD in the spike protein of SARS-CoV-2. We defined infection before P2 as natural infection (NI) and infection between P2 and P3 as breakthrough infection (BI) and compared susceptibility to further infection between the NI (-) and NI (+) groups and between BI (-) and BI (+) groups. Events in 485 participants who had a complete dataset of IgG (N) and IgG (RBD) from P1 to P4 were analyzed. Results: The presence of SARS-CoV-2 infection before P2 were examined by examining the titers of IgG (N)P1, IgG (N) P2, and IgG (RBD) P1 that exceeded the cutoff values. Consequently, 35 participants (7.22 %) were categorized into the NI (+) group, whereas 450 (92.8 %) were categorized into the NI (-) group. Between P2 and P3, the NI (-) group showed a higher rate of SARS-CoV-2 infection than the NI (+) group; however, there was no significant difference in the infection rate between P3 and P4. The infection rate was significantly lower in the BI (+) group than in the BI (-) group. Pre-primary vaccination infection significantly increased IgG (RBD) levels between P1 and P3. Post-primary vaccination infection significantly increased IgG (RBD) levels between P3 and P4. Conclusions: Infection with SARS-CoV-2 before or after receiving the mRNA COVID-19 vaccine can increase immune protection; however, the duration of this effect may be limited.

4.
Int J Mol Sci ; 25(13)2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-39000451

RESUMO

The nucleocapsid (N) protein of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a viral structural protein that is abundant in the circulation of infected individuals. Previous published studies reported controversial data about the role of the N protein in the activation of the complement system. It was suggested that the N protein directly interacts with mannose-binding lectin-associated serine protease-2 (MASP-2) and stimulates lectin pathway overactivation/activity. In order to check these data and to reveal the mechanism of activation, we examined the effect of the N protein on lectin pathway activation. We found that the N protein does not bind to MASP-2 and MASP-1 and it does not stimulate lectin pathway activity in normal human serum. Furthermore, the N protein does not facilitate the activation of zymogen MASP-2, which is MASP-1 dependent. Moreover, the N protein does not boost the enzymatic activity of MASP-2 either on synthetic or on protein substrates. In some of our experiments, we observed that MASP-2 digests the N protein. However, it is questionable, whether this activity is biologically relevant. Although surface-bound N protein did not activate the lectin pathway, it did trigger the alternative pathway in 10% human serum. Additionally, we detected some classical pathway activation by the N protein. Nevertheless, we demonstrated that this activation was induced by the bound nucleic acid, rather than by the N protein itself.


Assuntos
Lectina de Ligação a Manose da Via do Complemento , Proteínas do Nucleocapsídeo de Coronavírus , Serina Proteases Associadas a Proteína de Ligação a Manose , SARS-CoV-2 , Humanos , Serina Proteases Associadas a Proteína de Ligação a Manose/metabolismo , SARS-CoV-2/metabolismo , Proteínas do Nucleocapsídeo de Coronavírus/metabolismo , COVID-19/virologia , COVID-19/metabolismo , COVID-19/imunologia , Fosfoproteínas/metabolismo , Ligação Proteica , Ativação do Complemento
5.
Biosens Bioelectron ; 259: 116355, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38754196

RESUMO

Coronavirus disease 2019 (COVID-19) is a highly contagious illness caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), resulting in a global health crisis. The primary diagnostic method for COVID-19 is quantitative reverse transcription PCR, which is time-consuming and requires expensive instrumentation. Here, we developed an electrochemical biosensor for detecting SARS-CoV-2 biomarkers using a 3D porous polyacrylamide/polyaniline hydrogel (PPG) electrode prepared by UV photopolymerization and in situ polymerization. The electrochemical immunosensor for detecting SARS-CoV-2 N protein via the immune sandwich principle demonstrated a lower detection limit of 42 pg/mL and comparable specificity to a commercial enzyme-linked immunosorbent assay, which was additionally validated in pseudoviruses. The electrochemical sensor for hydrogen peroxide showed a low detection limit of 0.5 µM and excellent selectivity, which was further confirmed in cancer cells under oxidative stress. The biomarkers of SARS-CoV-2 were successfully detected due to the signal amplification capability provided by 3D porous electrodes and the high sensitivity of the antigen-antibody specific binding. This study introduces a novel three-dimensional electrode with great potential for the early detection of SARS-CoV-2.


Assuntos
Técnicas Biossensoriais , COVID-19 , Técnicas Eletroquímicas , Eletrodos , Hidrogéis , Peróxido de Hidrogênio , Limite de Detecção , SARS-CoV-2 , Peróxido de Hidrogênio/química , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/imunologia , Humanos , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , COVID-19/diagnóstico , COVID-19/virologia , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Hidrogéis/química , Proteínas do Nucleocapsídeo de Coronavírus/análise , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Fosfoproteínas/análise , Imunoensaio/instrumentação , Imunoensaio/métodos
6.
Chemistry ; 30(29): e202400048, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38483823

RESUMO

Recently, the discovery of antimicrobial peptides (AMPs) as excellent candidates for overcoming antibiotic resistance has attracted significant attention. AMPs are short peptides active against bacteria, cancer cells, and viruses. It has been shown that the SARS-CoV-2 nucleocapsid protein (N-P) undergoes liquid-liquid phase separation in the presence of RNA, resulting in biocondensate formation. These biocondensates are crucial for viral replication as they concentrate the viral RNA with the host cell's protein machinery required for viral protein expression. Thus, N-P biocondensates are promising targets to block or slow down viral RNA transcription and consequently virion assembly. We investigated the ability of three AMPs to interfere with N-P/RNA condensates. Using microscopy techniques, supported by biophysical characterization, we found that the AMP LL-III partitions into the condensate, leading to clustering. Instead, the AMP CrACP1 partitions into the droplets without affecting their morphology but reducing their dynamics. Conversely, GKY20 leads to the formation of fibrillar structures after partitioning. It can be expected that such morphological transformation severely impairs the normal functionality of the N-P droplets and thus virion assembly. These results could pave the way for the development of a new class of AMP-based antiviral agents targeting biocondensates.


Assuntos
Peptídeos Antimicrobianos , Proteínas do Nucleocapsídeo de Coronavírus , SARS-CoV-2 , SARS-CoV-2/efeitos dos fármacos , SARS-CoV-2/metabolismo , Peptídeos Antimicrobianos/química , Peptídeos Antimicrobianos/farmacologia , Proteínas do Nucleocapsídeo de Coronavírus/química , Proteínas do Nucleocapsídeo de Coronavírus/metabolismo , Humanos , RNA Viral/metabolismo , RNA Viral/química , Fosfoproteínas/química , Fosfoproteínas/metabolismo , Antivirais/farmacologia , Antivirais/química , Replicação Viral/efeitos dos fármacos
7.
ACS Appl Mater Interfaces ; 16(9): 11172-11184, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38388390

RESUMO

Lateral flow immunoassay (LFIA) has been widely used for the early diagnosis of diseases. However, conventional colorimetric LFIA possesses limited sensitivity, and the single-mode readout signal is easily affected by the external environment, leading to insufficient accuracy. Herein, multifunctional Fe3O4@MoS2@Pt nanotags with a unique "pompon mum"-like structure were triumphantly prepared, exhibiting excellent peroxidase (POD)-like activity, photothermal properties, and magnetic separation capability. Furthermore, the Fe3O4@MoS2@Pt nanotags were used to establish dual-mode LFIA (dLFIA) for the first time, enabling the catalytic colorimetric and photothermal dual-mode detection of severe acute respiratory syndrome coronavirus 2 nucleocapsid protein (SARS-CoV-2 NP) and influenza A (H1N1). The calculated limits of detection (cLODs) of SARS-CoV-2 NP and H1N1 were 80 and 20 ng/mL in catalytic colorimetric mode and 10 and 8 ng/mL in photothermal mode, respectively, demonstrating about 100 times more sensitive than the commercial colloidal Au-LFIA strips (1 ng/mL for SARS-CoV-2 NP; 1 µg/mL for H1N1). The recovery rates of dLFIA in simulated nose swab samples were 95.2-103.8% with a coefficient of variance of 2.3-10.1%. These results indicated that the proposed dLFIA platform showed great potential for the rapid diagnosis of respiratory viruses.


Assuntos
Vírus da Influenza A Subtipo H1N1 , Nanopartículas Metálicas , Molibdênio , Catálise , Colorimetria , Imunoensaio , Ouro
8.
J Infect Dis ; 229(5): 1382-1386, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38214559

RESUMO

The complexity of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and its variants in lung cells can truly be characterized only at the tissue and protein levels among unique cell subtypes. However, in vivo data are limited due to lack of accessible human tissues. Using a transgenic mouse model of SARS-CoV-2 infection and flow cytometry, we provide in vivo novel insight at the protein level that the differential impact of SARS-CoV-2 (Wuhan strain) and its B.1.617.2 (Delta) and BA.1 (Omicron) variants on lung may be attributed to differential patterns of viral protein levels among ciliated airway cells, alveolar types 1 and 2 cells, immune cells, and endothelial lung cells.


Assuntos
COVID-19 , Pulmão , Camundongos Transgênicos , SARS-CoV-2 , Análise de Célula Única , Animais , COVID-19/virologia , COVID-19/imunologia , Pulmão/virologia , Camundongos , Análise de Célula Única/métodos , Modelos Animais de Doenças , Humanos , Proteínas Virais/genética , Proteínas Virais/metabolismo
9.
Drug Discov Ther ; 17(5): 304-311, 2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-37899206

RESUMO

During an earlier multicenter, open-label, randomized controlled trial designed to evaluate the effectiveness of high-dose inhaled ciclesonide in patients with asymptomatic or mild coronavirus disease 2019 (COVID-19), we observed that worsening of shadows on CT without worsening of clinical symptoms was more common with ciclesonide. The present study sought to determine if an association exists between worsening CT shadows and impaired antibody production in patients treated with inhaled ciclesonide. Eighty-nine of the 90 patients in the original study were prospectively enrolled. After exclusions, there were 36 patients each in the ciclesonide and control groups. We analyzed antibody titers against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid protein at various time points. Changes in viral load during treatment were compared. There was no significant difference in age, sex, body mass index, background clinical characteristics, or symptoms between the two groups. Although evaluation on day 8 suggested a greater tendency for worsening shadows on CT in the ciclesonide group (p = 0.072), there was no significant difference between them in the ability to produce antibodies (p = 0.379) or the maximum antibody titer during the clinical course. In both groups, worsening CT shadows and higher viral loads were observed on days 1-8, suggesting ciclesonide does not affect clearance of the virus (p = 0.134). High-dose inhaled ciclesonide did not impair production of antibodies against SARS-CoV-2 or affect elimination of the virus, suggesting that this treatment can be used safely in patients with COVID-19 patients who use inhaled steroids for asthma and other diseases.


Assuntos
Asma , COVID-19 , Pregnenodionas , Humanos , SARS-CoV-2 , Pregnenodionas/uso terapêutico
10.
Biosens Bioelectron ; 240: 115662, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37669588

RESUMO

SARS-CoV-2 antigen detection plays a key role in the rapid diagnosis of COVID-19. However, current clinically used immunoassays are often limited by assay throughput, sensitivity, accuracy, and field operating conditions. To address these challenges, we constructed a self-enhanced electrochemiluminescence (ECL) array chip (SE2AC) for highly sensitive and label-free detection of SARS-CoV-2 nucleocapsid protein (N protein) with a facile and portable assay setup. Firstly, the self-enhanced ECL nanomaterials with inherent film-forming properties were synthesized by co-doping Ru(bpy)32+ and polyethyleneimine (PEI) in silica nanoparticles (Ru/PEI@SiO2). Secondly, a resistance-induced potential difference-based single-electrode electrochemical system (SEES) was adapted to serve as the electrode array to facilitate one-step assembly without the need for chip alignment. Thirdly, the chip electrode array was functionalized with the synthesized self-enhanced ECL emitters and captured antibodies. In addition, a portable detection box equipped with a smartphone was 3D-printed to serve as the chip holder and "dark room" for imaging acquisition. The SE2AC performance was validated with N protein with a limit of detection (LOD) of 0.47 pg/mL in the range of 1-10,000 pg/mL. Furthermore, the chip successfully detected the viral antigen residue as low as 1.92 pg/mL from diluted rehabilitation patients' serum samples. This is the first study reporting label-free detection of SARS-Cov-2 N protein based on a self-enhanced ECL immunosensor, which provides a novel facile method for highly sensitive diagnosis of COVID-19 with high throughput, portability, and low cost.


Assuntos
Técnicas Biossensoriais , COVID-19 , Humanos , Smartphone , SARS-CoV-2 , Dióxido de Silício , COVID-19/diagnóstico , Imunoensaio , Proteínas do Nucleocapsídeo
11.
Anal Biochem ; 670: 115137, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36997015

RESUMO

Chemiluminescence was used to test the susceptibility of the SARS-CoV-2 N and S proteins to oxidation by reactive oxygen species (ROS) at pH 7.4 and pH 8.5. The Fenton's system generates various ROS (H2O2, OH, -OH, OOH). All proteins were found to significantly suppress oxidation (the viral proteins exhibited 25-60% effect compared to albumin). In the second system, H2O2 was used both as a strong oxidant and as a ROS. A similar effect was observed (30-70%); N protein approached the effect of albumin at physiological pH (∼45%). In the O2.--generation system, albumin was most effective in the suppression of generated radicals (75%, pH 7.4). The viral proteins were more susceptible to oxidation (inhibition effect no more than 20%, compared to albumin). The standard antioxidant assay confirmed the strong antioxidant capacity of both viral proteins (1.5-1.7 fold higher than albumin). These results demonstrate the effective and significant inhibition of ROS-induced oxidation by the proteins. Obviously, the viral proteins could not be involved in the oxidative stress reactions during the course of the infection. They even suppress the metabolites involved in its progression. These results can be explained by their structure. Probably, an evolutionary self-defense mechanism of the virus has been developed.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Espécies Reativas de Oxigênio/metabolismo , Antioxidantes , Peróxido de Hidrogênio/metabolismo , Glicoproteína da Espícula de Coronavírus , Nucleocapsídeo/metabolismo , Inflamação , Albuminas , Anticorpos Antivirais
12.
ACS Infect Dis ; 9(3): 450-458, 2023 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-36735927

RESUMO

The lateral flow assay format enables rapid, instrument-free, at-home testing for SARS-CoV-2. Due to the absence of signal amplification, this simplicity comes at a cost in sensitivity. Here, we enhance sensitivity by developing an amplified lateral flow assay that incorporates isothermal, enzyme-free signal amplification based on the mechanism of hybridization chain reaction (HCR). The simplicity of the user experience is maintained using a disposable 3-channel lateral flow device to automatically deliver reagents to the test region in three successive stages without user interaction. To perform a test, the user loads the sample, closes the device, and reads the result by eye after 60 min. Detecting gamma-irradiated SARS-CoV-2 virions in a mixture of saliva and extraction buffer, the current amplified HCR lateral flow assay achieves a limit of detection of 200 copies/µL using available antibodies to target the SARS-CoV-2 nucleocapsid protein. By comparison, five commercial unamplified lateral flow assays that use proprietary antibodies exhibit limits of detection of 500 copies/µL, 1000 copies/µL, 2000 copies/µL, 2000 copies/µL, and 20,000 copies/µL. By swapping out antibody probes to target different pathogens, amplified HCR lateral flow assays offer a platform for simple, rapid, and sensitive at-home testing for infectious diseases. As an alternative to viral protein detection, we further introduce an HCR lateral flow assay for viral RNA detection.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Teste para COVID-19 , Limite de Detecção , RNA Viral/genética
13.
Sens Actuators B Chem ; 380: 133387, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36694572

RESUMO

Antigen-detecting rapid diagnostic testing (Ag-RDT) has contributed to containing the spread of SARS-CoV-2 variants of concern (VOCs). In this study, we proposed a biomimetic clamp assay for impedimetric SARS-CoV-2 nucleocapsid protein (Np) detection. The DNA biomimetic clamp (DNA-BC) is formed by a pair of Np aptamers connected via a T20 spacer. The 5'- terminal of the DNA-BC is phosphate-modified and then anchored on the surface of the screen-printed gold electrode, which has been pre-coated with Au@UiO-66-NH2. The integrated DNA-material sensing biochip is fabricated through the strong Zr-O-P bonds to form a clamp-type impedimetric aptasensor. It is demonstrated that the aptasensor could achieve Np detection in one step within 11 min and shows pronounced sensitivity with a detection limit of 0.31 pg mL-1. Above all, the aptasensor displays great specificity and stability under physiological conditions as well as various water environments. It is a potentially promising strategy to exploit reliable Ag-RDT products to confront the ongoing epidemic.

14.
Bioelectrochemistry ; 150: 108358, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36580690

RESUMO

A sensitive, reliable, and cost-effective detection for SARS-CoV-2 was urgently needed due to the rapid spread of COVID-19. Here, a "signal-on" magnetic-assisted PEC immunosensor was constructed for the quantitative detection of SARS-CoV-2 nucleocapsid (N) protein based on Z-scheme heterojunction. Fe3O4@SiO2@Au was used to connect the capture antibody to act as a capture probe (Fe3O4@SiO2@Au/Ab1). It can extract target analytes selectively in complex samples and multiple electrode rinsing and assembly steps were avoided effectively. CdTe QDs sensitized TiO2 coated on the surface of SiO2 spheres to form Z-scheme heterojunction (SiO2@TiO2@CdTe QDs), which broadened the optical absorption range and inhibited the quick recombination of photogenerated electron/hole of the composite. With fascinating photoelectric conversion performance, SiO2@TiO2@CdTe QDs were utilized as a signal label, thus further realizing signal amplification. The migration mechanism of photogenerated electrons was further deduced by active material quenching experiment and electron spin resonance (ESR) measurement. The elaborated immunosensor can detect SARS-CoV-2 N protein in the linear range of 0.005-50 ng mL-1 with a low detection limit of 1.8 pg mL-1 (S/N = 3). The immunosensor displays extraordinary sensitivity, strong anti-interference, and high reproducibility in detecting SARS-CoV-2 N protein, which envisages its potential application in the clinical diagnosis of COVID-19.


Assuntos
Técnicas Biossensoriais , COVID-19 , Compostos de Cádmio , Nanocompostos , Pontos Quânticos , Humanos , COVID-19/diagnóstico , Técnicas Eletroquímicas , Imunoensaio , Limite de Detecção , Fenômenos Magnéticos , Proteínas do Nucleocapsídeo , Reprodutibilidade dos Testes , SARS-CoV-2 , Dióxido de Silício , Telúrio
15.
J Formos Med Assoc ; 122(5): 376-383, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36564300

RESUMO

BACKGROUND/PURPOSE: Healthcare workers (HCWs) are at risk of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection due to occupational exposure. We aim to investigate the prevalence and risk factors of SARS-CoV-2 infection among HCWs during epidemic outbreak of omicron variant in Taiwan. METHODS: Sequential reserved serum samples collected from our previous study during December 2021 and July 2022 were tested for antibodies against SARS-CoV-2 nucleocapsid protein (NP). Diagnosis of SARS-CoV-2 infection was defined as positive either of anti-SARS-CoV-2 nucleoprotein, rapid antigen test or polymerase chain reaction. Retrospective chart review and a questionnaire were used to access the symptoms and risk factors for SARS-CoV-2 infection. RESULTS: Totally 300 participants (69.3% female) with a median age of 37.9 years were enrolled. A significant increase incidence of SARS-CoV-2 infection was found before and during community outbreak (11.91 versus 230.93 per 100,000 person-days, P < 0.001), which was a trend paralleling that observed in the general population. For 61 SARS-CoV-2 infected participants, nine (14.8%) were asymptomatic. Multivariate analysis revealed recent contact with a SARS-CoV-2 infected household (odds ratio [OR], 7.01; 95% confidence interval [95% CI], 3.70-13.30; P < 0.001) and co-existed underlying autoimmune diseases (OR, 4.46; 95% CI, 1.28-15.51; P = 0.019) were significant risk factors associated with acquisition of SARS-CoV-2 infection among HCWs. CONCLUSION: Community factors, such as closely contact with SARS-CoV-2 infected individuals and underlying immune suppression status, were significant factors for acquisition of SARS-CoV-2 infection among HCWs. We suggest the application of appropriate infection control measures for HCWs should be maintained to reduce risk of SARS-CoV-2 infection.


Assuntos
COVID-19 , Humanos , Feminino , Adulto , Masculino , COVID-19/epidemiologia , COVID-19/prevenção & controle , SARS-CoV-2 , Estudos Retrospectivos , Taiwan/epidemiologia , Surtos de Doenças/prevenção & controle , Pessoal de Saúde , Vacinação
16.
Anal Chim Acta ; 1234: 340522, 2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36328721

RESUMO

At the end of 2019, the novel coronavirus disease 2019 (COVID-19), a cluster of atypical pneumonia caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has been known as a highly contagious disease. Herein, we report the MXene/P-BiOCl/Ru(bpy)32+ heterojunction composite to construct an electrochemiluminescence (ECL) immunosensor for SARS-CoV-2 nucleocapsid protein (CoVNP) determination. Two-dimensional (2D) material ultrathin phosphorus-doped bismuth oxychloride (P-BiOCl) is exploited and first applied in ECL. 2D architectures MXene not only act as "soft substrate" to improve the properties of P-BiOCl, but also synergistically work with P-BiOCl. Owing to the inimitable set of bulk and interfacial properties, intrinsic high electrochemical conductivity, hydrophilicity and good biocompatible of 2D/2D MXene/P-BiOCl/Ru(bpy)32+, this as-exploited heterojunction composite is an efficient signal amplifier and co-reaction accelerator in the presence of tri-n-propylamine (TPA) as a coreactant. The proposed MXene/P-BiOCl/Ru(bpy)32+-TPA system exhibits a high and stable ECL signal and achieves ECL emission quenching for "signal on-off" recognition of CoVNP. Fascinatingly, the constructed ECL biosensor towards CoVNP allows a wide linear concentration range from 1 fg/mL to 10 ng/mL and a low limit of detection (LOD) of 0.49 fg/mL (S/N = 3). Furthermore, this presented strategy sheds light on designing a highly efficient ECL nanostructure through the combination of 2D MXene architectures with 2D semiconductor materials in the field of nanomedicine. This ECL biosensor can successfully detect CoVNP in human serum, which can promote the prosperity and development of diagnostic methods of SARS-CoV-2.


Assuntos
Técnicas Biossensoriais , COVID-19 , Humanos , Técnicas Biossensoriais/métodos , Bismuto , COVID-19/diagnóstico , Técnicas Eletroquímicas/métodos , Imunoensaio/métodos , Medições Luminescentes/métodos , Proteínas do Nucleocapsídeo , SARS-CoV-2
17.
J Transl Autoimmun ; 5: 100175, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36447819

RESUMO

Introduction: Viral infections have been implicated in the initiation of the autoimmune diseases. Recent reports suggest that a proportion of patients with COVID-19 develop severe disease with multiple organ injuries. We evaluated the relationship between COVID-19 severity, prevalence and persistence of antinuclear and other systemic and organ specific autoantibodies as well as SARS-CoV-2 infection specific anti-nucleocapsid (N) IgG antibodies and protective neutralizing antibody (Nab) levels. Methods: Samples from 119 COVID-19 patients categorized based on their level of care and 284 healthy subjects were tested for the presence and persistence of antinuclear and other systemic and organ specific autoantibodies as well as SARS-CoV-2 and neutralizing antibody levels. Results: The data shows significantly increased levels of anti RNP-A, anti-nucleocapsid and neutralizing antibody among patients receiving ICU care compared to non-ICU care. Furthermore, subjects receiving ICU care demonstrated significantly higher nucleocapsid IgG levels among the RNP-A positive cohort compared to RNP-A negative cohort. Notably, the expression of anti RNP-A antibodies is transient that reverts to non-reactive status between 20 and 60 days post symptom onset. Conclusions: COVID-19 patients in ICU care exhibit significantly higher levels of transient RNP-A autoantibodies, anti-nucleocapsid, and SARS-CoV-2 neutralizing antibodies compared to patients in non-ICU care.

18.
Biosens Bioelectron ; 218: 114737, 2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36183582

RESUMO

Lateral flow immunoassays (LFIA) have a plethora of applications in health, environmental and food sectors for low-cost, simple, and rapid point-of-need testing. Typically, the user only needs to add the sample without any other intervention from sample application to results. A compelling challenge, and a constant pursuit in LFIA is to improve the assay sensitivity without compromising the simplicity and practicality. We report that the addition of water-soluble macromolecular crowding agents leads to an enhancement of the sensitivity, which is attributed to the fact that the exposure of antibodies and micro/nanoparticle conjugates to macromolecularly crowded environment, while migrating through the confining pores of the strip-pads by capillary forces, promotes the interactions that are responsible for analyte recognition and signal generation. The effect was shown by using two of the most widely established LFIA tests worldwide, that is, detection of nucleocapsid protein from SARS-CoV-2 associated with COVID-19 and detection of Strep-A antigen from Streptococcus pyogenes associated with pharyngitis. For immediate demonstration of the sensitivity enhancement, we worked directly on commercially available devices already optimized in terms of reagents and conditions. Of the crowders used, ficoll, Mr 400000, and ficoll, Mr 70000, gave a 5-10-fold improvement of the signal without affecting the background. Because the addition of macromolecular crowding agents is complementary to other strategies of sensitivity enhancement, such as the design of novel labels and the introduction of signal amplification, we anticipate that the proposed modulation will be extended to numerous analytes with a variety of reporters and LFIA configurations.


Assuntos
Técnicas Biossensoriais , COVID-19 , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Ficoll , Imunoensaio/métodos , Proteínas do Nucleocapsídeo , Água , Sensibilidade e Especificidade
19.
Anal Chim Acta ; 1233: 340486, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36283777

RESUMO

The SARS-CoV-2 pandemic has posed a huge challenge to rapid and accurate diagnosis of SARS-CoV-2 in the early stage of infection. In this work, we developed a novel magnetic/fluorescent dual-modal lateral flow immunoassay (LFIA) based on multifunctional nanobeads for rapid and accurate determination of SARS-CoV-2 nucleocapsid protein (NP). The multifunctional nanobeads were fabricated by using polyethyleneimine (PEI) as a mediate shell to combine superparamagnetic Fe3O4 core with dual quantum dot shells (MagDQD). The core-shell structure of MagDQD label with high loading density of quantum dots (QDs) and superior magnetic content realized LFIA with dual quantitative analysis modal from the assemblies of individual single nanoparticles. The LFIA integrated the advantages of magnetic signal and fluorescent signal, resulting excellent accuracy for quantitative analysis and high elasticity of the overall detection. In addition, magnetic signal and fluorescent signal both had high sensitivity with the limit of detection (LOD) as 0.235 ng mL-1 and 0.012 ng mL-1, respectively. The recovery rates of the methods in simulated saliva samples were 91.36%-103.60% (magnetic signal) and 94.39%-104.38% (fluorescent signal). The results indicate the method has a considerable potential to be an effective tool for diagnose SARS-CoV-2 in the early stage of infection.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Polietilenoimina , COVID-19/diagnóstico , Imunoensaio/métodos , Fenômenos Magnéticos
20.
Cell ; 185(19): 3603-3616.e13, 2022 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-36084631

RESUMO

The effects of mutations in continuously emerging variants of SARS-CoV-2 are a major concern for the performance of rapid antigen tests. To evaluate the impact of mutations on 17 antibodies used in 11 commercially available antigen tests with emergency use authorization, we measured antibody binding for all possible Nucleocapsid point mutations using a mammalian surface-display platform and deep mutational scanning. The results provide a complete map of the antibodies' epitopes and their susceptibility to mutational escape. Our data predict no vulnerabilities for detection of mutations found in variants of concern. We confirm this using the commercial tests and sequence-confirmed COVID-19 patient samples. The antibody escape mutational profiles generated here serve as a valuable resource for predicting the performance of rapid antigen tests against past, current, as well as any possible future variants of SARS-CoV-2, establishing the direct clinical and public health utility of our system.


Assuntos
COVID-19 , SARS-CoV-2 , Animais , Anticorpos Neutralizantes , Anticorpos Antivirais , Epitopos/genética , Humanos , Mamíferos , Mutação , Nucleocapsídeo , SARS-CoV-2/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA