Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 410(13): 3185-3196, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29582122

RESUMO

Frankincense gum resin secreted from Boswellia papyrifera was analysed by comprehensive 2D gas chromatography hyphenated with accurate mass time-of-flight mass spectrometry (GC×GC-accTOFMS). Direct multiple injection experiments with stepwise isothermal temperature programming were then performed to construct isovolatility curves for reference alkane series in GC×GC. This provides access to calculation of second dimensional retention indices (2I). More than 500 peaks were detected and 220 compounds mainly comprising monoterpenes, sesquiterpenes, diterpenes and oxygenated forms of these compounds were identified according to their 1I, 2I and accurate mass data. The study demonstrates the capability of GC×GC-accTOFMS with retention data on two separate column phases, as an approach for improved component identification. A greater number of identified and/or tentatively identified terpenoids in this traditional Chinese medicine allow for a more comprehensive coverage of the volatile composition of frankincense.


Assuntos
Boswellia/química , Franquincenso/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Terpenos/análise , Compostos Orgânicos Voláteis/análise , Alcanos/análise
2.
J Chromatogr A ; 1539: 62-70, 2018 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-29395161

RESUMO

Comprehensive two-dimensional gas chromatography mass spectrometry (GC × GC-MS) has been widely used for analysis of volatile compounds. However, the second dimension retention index (I) of each compound is not widely used to aid compound identification owing to the limited accuracy of I calculation. We report a surface fitting approach to the calculation of I using n-alkanes (C7-C30) as references, where the second dimension retention time (2tR) and the second dimension column temperature (2Te) formed the X-Y plane and the I was the Z-axis to form the I surface. Compared to the conventional approach for calculating I using isovolatility curves, the surface fitting approach eliminated the construction of isovolatility curves for the reference compounds and gives better reproducibility. The goodness of the proposed surface fitting achieved R2 = 0.9999 and RMSE = 6.1 retention index units (iu). Ten-fold cross validation demonstrated the surface fitting approach had a good predictability with average R2 = 0.9999 and RMSE = 6.6 iu. The developed method was also applied to calculate the second dimension retention indices of compound standards in two commercial mixtures MegaMix A and MegaMix B. The mean standard deviation of the calculated I was only 1.6 iu for compounds in MegaMix A and 3.4 iu for compounds in MegaMix B. Compared with the literature results, the small value of standard deviation in the calculated retention index using surface fitting method shows that the surface fitting method has less measurement variability than the conventional isovolatility curve approach.


Assuntos
Técnicas de Química Analítica/métodos , Cromatografia Gasosa-Espectrometria de Massas , Alcanos/química , Modelos Químicos , Reprodutibilidade dos Testes , Temperatura , Compostos Orgânicos Voláteis/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA