Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Curr Glaucoma Pract ; 16(2): 96-104, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36128077

RESUMO

Aim: To investigate whether steady state pattern electroretinogram (ssPERG) could identify retinal ganglion cell (RGC) dysfunction, and to assess the relationship between ssPERG with optical coherence tomography (OCT) measurements in glaucoma suspects (GS). Materials and methods: This was a prospective cohort study of GS, identified based on suspicious optic disk appearance and glaucoma risk factors. Complete eye exam, Standard automated perimetry, OCT, and ssPERG were performed. Magnitude (Mag), Magnitude D (MagD), and MagD/Mag ratio were subsequently used in the correlation and linear regression analyses between ssPERG parameters and the RNFL, GCL/IPL, and macular thicknesses measurements. Results: Forty-nine eyes of 26 patients were included. Mag and MagD were significantly correlated with the superior, inferior, and average RNFL thicknesses (avRNFLT). All ssPERG parameters were significantly correlated with the average and minimum GCL/IPL thicknesses and the inner macular sector thicknesses. Mag and MagD significantly predicted the superior, inferior, and avRNFLT in the regression analysis. All ssPERG parameters were predictive of GCL/IPL thickness in all sectors as well as the average and minimum GCL/IPL thicknesses. All ssPERG parameters were predictive of all inner macular sector thicknesses and MagD was also predictive of some outer macular sector thicknesses as well. Conclusion: ssPERG has significant correlations with and is predictive of RNFL, GCL/IPL, and macular thicknesses in glaucoma suspects. Clinical significance: ssPERG may serve as a useful objective functional tool for identifying and following the progression of disease in glaucoma suspects. How to cite this article: Tirsi A, Wong A, Zhu D, et al. Pattern Electroretinogram Parameters and their Associations with Optical Coherence Tomography in Glaucoma Suspects. J Curr Glaucoma Pract 2022;16(2):96-104.

2.
Ophthalmol Ther ; 9(4): 981-992, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32939747

RESUMO

INTRODUCTION: This study evaluates the effects of the multi-pressure dial (MPD) on steady-state pattern electroretinography (ss-pERG) parameters. The study is a randomized, controlled, prospective, pilot trial in a private practice setting with ocular hypertensive (OHT), glaucoma suspect, and open-angle glaucoma (OAG) subjects. METHODS: This study included nine patients (64 ± 9.0 years, nine female) with OHT, glaucoma suspect, or mild OAG. One eye of each subject was randomized to receive negative periocular pressure, while the contralateral eye served as the intrasubject control through the goggle without negative pressure. The Diopsys High Contrast Sensitivity ss-pERG protocol was conducted on both eyes of each subject while wearing the MPD device. Application of negative periocular pressure was set at 50% of baseline intraocular pressure for each study eye. RESULTS: Following 2 h of negative periocular pressure application, the difference in MagnitudeD (MagD) from baseline for eyes randomized to receive negative periocular pressure (+ 0.17 versus - 0.26) was statistically significant (p = 0.023). Over the same period, the change in MagD/Magnitude (MagD/Mag ratio) from baseline for eyes randomized to receive negative periocular pressure was also higher (+ 0.14 versus - 0.16), compared to the control eyes, approached significance (p = 0.059). CONCLUSIONS: Following 2 h of MPD wear, the measured MagD and MagD/Mag ratio improved compared to control, suggesting that negative periocular pressure application to the anterior globe can lead to short-term improvement in one measure of retinal ganglion cell function.

3.
Clin Ophthalmol ; 13: 2451-2459, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31849443

RESUMO

PURPOSE: Dyslexia is a reading disorder with neurological deficit of the magnocellular pathway. The aim of our study was to evaluate the functionality of the magnocellular-Y (M-Y) retinal ganglion cells in adult dyslexic subjects using steady-state pattern electroretinogram and frequency doubling perimetry. METHODS: Ten patients with dyslexia (7 females and 3 males), mean age 28.7 ± 5.9 years, and 10 subjects without dyslexia (6 females and 4 males), mean age 27.8 ± 4.1 years, were enrolled in the study and underwent both steady-state pattern-electroretinogram examination and frequency doubling perimetry. RESULTS: There was a significant difference in the amplitude of the steady-state pattern electroretinogram of the dyslexic group and the healthy controls (0.610±0.110 µV vs 1.250±0.296 µV; p=0.0001). Furthermore, in the dyslexic group we found a significant difference between the right eye and the left eye (0.671±0.11 µV vs 0.559±0.15 µV; p=0.001). With frequency doubling perimetry, the pattern standard deviation index increased in dyslexic eyes compared to healthy controls (4.40±0.81 dB vs 2.99±0.35 dB; p=0.0001) and in the left eye versus the right eye of the dyslexic group (4.43±1.10 dB vs 3.66±0.96 dB; p=0.031). There was a correlation between the reduction in the wave amplitude of the pattern electroretinogram and the simultaneous increase in the pattern standard deviation values (r=0.80; p=0.001). This correlation was also found to be present in the left eye (r=0.93; p<0.001) and the right eye (r=0.81; p=0.005) of dyslexic subjects. CONCLUSION: Our study shows that there was an alteration of the activity of M-Y retinal ganglion cells, especially in the left eye. It confirms that in dyslexia there is a deficit of visual attention with damage not only of the magnocellular-dorsal pathway but also of the M-Y retinal ganglion cells.

4.
Doc Ophthalmol ; 139(3): 185-195, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31312944

RESUMO

PURPOSE: To evaluate the repeatability of the steady-state pattern electroretinogram (PERG) and full-field flicker electroretinogram (Flicker ERG) protocols, delivered by the office-based Neuro Optic Vision Assessment (NOVA)™ testing platform, in healthy subjects. METHODS: Healthy individuals underwent PERG (16° and 24°) and Flicker ERG [fixed luminance (FL) and multi-luminance (ML)] testing protocols. Test-retest repeatability of protocols was calculated using intra-class correlation coefficients (ICC). Reference values of the parameters of the aforementioned tests were also calculated. RESULTS: The ICCs for the PERG parameters ranged from 0.793 to 0.911 (p < 0.001). The ICCs for the Flicker ERG parameters ranged from 0.968 to 0.994 (p < 0.001). A linear regression analysis was applied to assess the impact of age on ERG responses. Age had a significant impact on all PERG parameters (16° or 24°). The phase response of the FL Flicker ERG significantly decreased with age (ß = - 0.837, p ≤ 0.001). The FL Flicker ERG Magnitude was also impacted with a significant quadratic effect of age (ß = - 0.0047, p = 0.0004). Similarly, the Phase Area Under the Curve (Phase AUC) of the ML Flicker ERG significantly declined with age (ß = - 0.007, p = 0.009), and the impact on the Magnitude AUC was significant as well, with a negative quadratic age effect. CONCLUSIONS: The PERG and Flicker ERG protocols, delivered by an office-based testing platform, were shown to have good-to-excellent test-retest repeatability when tests were performed in the same order and in immediate succession.


Assuntos
Eletrorretinografia/normas , Retina/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/fisiologia , Estudos Transversais , Eletrorretinografia/métodos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
5.
Clin Exp Ophthalmol ; 46(1): 54-61, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28600806

RESUMO

IMPORTANCE: This study evaluates two rapid electrophysiological glaucoma diagnostic tests that may add a functional perspective to glaucoma diagnosis. BACKGROUND: This study aimed to determine the ability of two office-based electrophysiological diagnostic tests, steady-state pattern electroretinogram and short-duration transient visual evoked potentials, to discern between glaucomatous and healthy eyes. DESIGN: This is a cross-sectional study in a hospital setting. PARTICIPANTS: Forty-one patients with glaucoma and 41 healthy volunteers participated in the study. METHODS: Steady-state pattern electroretinogram and short-duration transient visual evoked potential testing was conducted in glaucomatous and healthy eyes. A 64-bar-size stimulus with both a low-contrast and high-contrast setting was used to compare steady-state pattern electroretinogram parameters in both groups. A low-contrast and high-contrast checkerboard stimulus was used to measure short-duration transient visual evoked potential parameters in both groups. MAIN OUTCOME MEASURES: Steady-state pattern electroretinogram parameters compared were MagnitudeD, MagnitudeD/Magnitude ratio, and the signal-to-noise ratio. Short-duration transient visual evoked potential parameters compared were amplitude and latency. RESULTS: MagnitudeD was significantly lower in glaucoma patients when using a low-contrast (P = 0.001) and high-contrast (P < 0.001) 64-bar-size steady-state pattern electroretinogram stimulus. MagnitudeD/Magnitude ratio and SNR were significantly lower in the glaucoma group when using a high-contrast 64-bar-size stimulus (P < 0.001 and P = 0.010, respectively). Short-duration transient visual evoked potential amplitude and latency were not significantly different between the two groups. CONCLUSIONS AND RELEVANCE: Steady-state pattern electroretinogram was effectively able to discern between glaucomatous and healthy eyes. Steady-state pattern electroretinogram may thus have a role as a clinically useful electrophysiological diagnostic tool.


Assuntos
Eletrorretinografia/métodos , Potenciais Evocados Visuais/fisiologia , Glaucoma de Ângulo Aberto/diagnóstico , Pressão Intraocular/fisiologia , Idoso , Estudos Transversais , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Campos Visuais/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA