Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Environ Pollut ; 230: 663-673, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28715771

RESUMO

In this paper problems associated with preparation of aqueous standard of highly hydrophobic compounds such as partial precipitation, being lost on the surfaces, low solubility in water and limited sample volume for accurate determination of their distribution coefficients are addressed. The following work presents two approaches that utilize blade thin film microextraction (TFME) to investigate partitioning of UV filters and biocides to humic acid (dissolved organic carbon) and sediment. A steady-state concentration of target analytes in water was generated using a flow-through aqueous standard generation (ASG) system. Dialysis membranes, a polytetrafluoroethylene permeation tube, and a frit porous (0.5 µm) coated by epoxy glue were basic elements used for preparation of the ASG system. In the currently presented study, negligible depletion TFME using hydrophilic-lipophilic balance (HLB) and octadecyl silica-based (C18) sorbents was employed towards the attainment of free concentration values of target analytes in the studied matrices. Thin film geometry provided a large volume of extraction phase, which improved the sensitivity of the method towards highly matrix-bound analytes. Extractions were performed in the equilibrium regime so as to prevent matrix effects and with aims to reach maximum method sensitivity for all analytes under study. Partitioning of analytes on dissolved organic carbon (DOC) was investigated in ASG to facilitate large sample volume conditions. Binding percentages and DOC distribution coefficients (Log KDOC) ranged from 20 to 98% and 3.71-6.72, respectively. Furthermore, sediment-water partition coefficients (Kd), organic-carbon normalized partition coefficients (Log KOC), and DOC distribution coefficients (Log KDOC) were investigated in slurry sediment, and ranged from 33 to 2860, 3.31-5.24 and 4.52-5.75 Lkg-1, respectively. The obtained results demonstrated that investigations utilizing ASG and TFME can yield reliable binding information for compounds with high log KOW values. This information is useful for study of fate, transport, and ecotoxicological effects of UV filters and biocides in aquatic environment.


Assuntos
Desinfetantes/análise , Monitoramento Ambiental/métodos , Sedimentos Geológicos/química , Substâncias Húmicas/análise , Protetores Solares/análise , Poluentes Químicos da Água/análise , Monitoramento Ambiental/instrumentação , Interações Hidrofóbicas e Hidrofílicas , Microextração em Fase Líquida , Membranas Artificiais , Microextração em Fase Sólida , Solubilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA