Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
JACC Cardiovasc Interv ; 17(15): 1795-1807, 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39142756

RESUMO

BACKGROUND: The Valve Academic Research Consortium (VARC)-3 definition for neurologic events after transcatheter aortic valve replacement (TAVR) lacks clinical validation. OBJECTIVES: This study sought to determine the incidence, predictors, and clinical impact of neurologic events following TAVR as defined by VARC-3 criteria. METHODS: This was a multicenter study including 2,924 patients with severe aortic stenosis undergoing TAVR. Based on Neurologic Academic Research Consortium (NeuroARC) classification, neurologic events were classified as NeuroARC type 1 (stroke), NeuroARC type 2 (covert central nervous system injury), and NeuroARC type 3 (transient ischemic attack and delirium). Baseline, procedural, and follow-up data were prospectively collected in a dedicated database. RESULTS: After a median follow-up of 13 (7-37) months, neurologic events occurred in 471 patients (16.1%), NeuroARC type 1, 2, and 3 in 37.4%, 4.7%, and 58.0% of cases, respectively, and the majority (58.6%) were periprocedural. Advanced age, chronic kidney disease, atrial fibrillation, major vascular complications, and in-hospital bleeding determined an increased risk of periprocedural events (P < 0.03 for all). Neurologic events occurring during the periprocedural time frame were independently associated with a substantial increase in mortality at 1 year after the intervention (HR: 1.91; 95% CI: 1.23-2.97; P = 0.004). However, although NeuroARC type 1 was associated with an increased mortality risk (IRR: 3.38; 95% CI: 2.30-5.56; P < 0.001 and IRR: 21.7; 95% CI: 9.63-49.1; P < 0.001 for ischemic and hemorrhagic stroke, respectively), the occurrence of NeuroARC type 3 events had no impact on mortality. CONCLUSIONS: Neurologic events after TAVR were associated with poorer short- and long-term survival. This correlation was related to the type of NeuroARC event defined by the VARC-3 criteria. Given the negative impact on clinical outcomes, every attempt should be made to reduce the risk of neurologic complications after TAVR.


Assuntos
Estenose da Valva Aórtica , Ataque Isquêmico Transitório , Índice de Gravidade de Doença , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Fatores de Risco , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Incidência , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Fatores de Tempo , Medição de Risco , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/mortalidade , Ataque Isquêmico Transitório/epidemiologia , Resultado do Tratamento , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Delírio/epidemiologia , Delírio/etiologia , Delírio/diagnóstico , Delírio/mortalidade , Bases de Dados Factuais , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem
2.
Sisli Etfal Hastan Tip Bul ; 58(2): 216-225, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39021695

RESUMO

Objectives: Predictive risk scores have a significant impact on patient selection and assessing the likelihood of complications following interventions in patients with severe aortic stenosis (AS). This study aims to explore the utility of machine learning (ML) techniques in predicting 30-day major adverse cardiac events (MACE) by analyzing parameters, including the Global Registry of Acute Coronary Events (GRACE) score. Methods: This retrospective, multi-center, observational study enrolled 453 consecutive patients diagnosed with severe AS who underwent transcatheter aortic valve implantation (TAVI) from April 2020 to January 2023. The primary outcome was defined as a composition of MACE comprising periprocedural myocardial infarction (MI), cerebrovascular events (CVE), and all-cause mortality during the 1-month follow-up period after the procedure. Conventional binomial logistic regression and ML models were utilized and compared for prediction purposes. Results: The study population had a mean age of 76.1, with 40.8% being male. The primary endpoint was observed in 7.5% of cases. Among the individual components of the primary endpoint, the rates of all-cause mortality, MI, and CVE were reported as 4.2%, 2.4%, and 1.9%, respectively. The ML-based Extreme Gradient Boosting (XGBoost) model with the GRACE score demonstrated superior discriminative performance in predicting the primary endpoint, compared to both the ML model without the GRACE score and the conventional regression model [Area Under the Curve (AUC)= 0.98 (0.91-0.99), AUC= 0,87 (0.80-0.98), AUC= 0.84 (0.79-0.96)]. Conclusion: ML techniques hold the potential to enhance outcomes in clinical practice, especially when utilized alongside established clinical tools such as the GRACE score.

3.
Clin Res Cardiol ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748208

RESUMO

BACKGROUND: Right ventricular (RV) dysfunction in patients undergoing transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) has long been disregarded. We aimed to assess the predictive value of RV to pulmonary artery coupling (RV/PAc), defined as tricuspid annular plane systolic excursion to systolic pulmonary artery pressure, on mortality in different flow types of AS after TAVI. METHODS: All patients undergoing TAVI for AS at our centre between 2018 and 2020 were assessed; 862 patients were analysed. The cohort was dichotomized using a ROC analysis (cut-off 0.512 mm/mmHg), into 429 patients with preserved and 433 patients with reduced RV/PAc. RESULTS: Reduced RV/PAc was associated with male sex and a higher rate of comorbidities. Short-term VARC-3 endpoints and NYHA classes at follow-up were comparable. Reduced RV/PAc was associated with higher 2-year all-cause mortality (35.0% [30.3-39.3%] vs. 15.4% [11.9-18.7%], hazard ratio 2.5 [1.9-3.4], p < 0.001). Cardiovascular mortality was almost tripled. Results were consistent after statistical adjustment and in a multivariate model. Sub-analyses of AS flow types revealed lower RV/PAc in classical and paradoxical low-flow low-gradient AS, with the majority having reduced RV/PAc (74% and 59%). RV/PAc retained its predictive value in these subgroups. CONCLUSIONS: RV dysfunction defined by low RV/PAc is a strong mortality predictor after TAVI independent of flow group. It should be incorporated in future TAVI risk assessment.

4.
Am J Cardiol ; 221: 102-109, 2024 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-38636623

RESUMO

Transcatheter aortic valve implantation (TAVI) is an established treatment strategy in aortic valve disease. Infolding, as a nonuniform expansion of the prosthesis leading to introflection of part of the device circumference, is a complication specific to self-expandable prostheses. The aim of the study is to determine incidence, predictors, treatment strategy, and outcomes of infolding during Medtronic Evolut TAVI (Minneapolis, MN, US). Between January 2018 and March 2022, all patients treated with Evolut TAVI were included in a multicenter observational retrospective study. According to the occurrence of infolding, the enrolled cohort was divided into 2 groups; periprocedural characteristics and 30-day outcomes were compared. A total of 1,470 patients were included; 23 infolding cases (1.6%) were detected. Preprocedural imaging showed larger aortic anatomy and greater calcium burden in the infolding group. Infolding occurred mostly with Evolut Pro+ and size 34 mm and was diagnosed before full prosthesis release in 78.3%. The rate of moderate-to-severe paravalvular regurgitation was higher in the infolding group (21.7% vs 1.9%, p <0.001). Short-term follow-up showed greater all-cause and cardiovascular mortality (respectively, 4.3% vs 0.7% and 4.3% vs 0.6%, p <0.05) and higher rate of pacemaker implantation (33.3% vs 15.7%, p = 0.042) in case of infolding. High right cusp calcium score and resheathing maneuvers were independent predictors of infolding. In conclusion, prosthesis infolding is a TAVI complication burdened by worse cardiovascular outcomes. Prompt intraprocedural infolding diagnosis is pivotal, especially in case of great native valve calcium burden and resheathing maneuvers, to safely overcome this complication by prosthesis recapture or postdilation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Incidência , Idoso , Falha de Prótese , Complicações Pós-Operatórias/epidemiologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia
5.
Catheter Cardiovasc Interv ; 103(1): 186-193, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38140761

RESUMO

BACKGROUND: Patients undergoing transcatheter aortic valve implantation (TAVI) frequently have coronary artery disease requiring percutaneous coronary intervention (PCI). Usually, PCI and TAVI are performed in two separate procedures and current studies are investigating potential benefits regarding the order. However, the two interventions may also be performed simultaneously, thereby limiting the risk associated with repeated vascular access. Data evaluating benefit and harm of concomitant procedures are scarce. AIMS: Therefore, this study aimed to evaluate concomitant PCI (coPCI) in TAVI patients regarding Valve Academic Research Consortium 3 (VARC-3) endpoints and long-term mortality. METHODS: A total of 2233 consecutive TAVI patients from the EVERY-VALVE registry were analyzed according to the VARC-3 endpoint definitions. A total of 274 patients had undergone TAVI and concomitant PCI (coPCI group). They were compared to 226 TAVI patients who had received PCI within 60 days before TAVI in a stepwise approach (swPCI group) and to the remaining 1733 TAVI patients who had not undergone PCI recently (noPCI group). RESULTS: Overall median age was 81.4 years, median Society of Thoracic Surgeons score was 4.0%. Patients in the coPCI and in the swPCI group were predominantly male with reduced left-ventricular ejection fraction. Rates of VARC-3 composite endpoints technical success and 30-day device success were comparable between all three groups. Mortality rates at 3 years after TAVI were similar (coPCI, 34.2% vs. swPCI, 31.9% vs. noPCI, 34.0% p = 0.84). CONCLUSIONS: coPCI during TAVI seems comparable in a retrospective analysis. Compared to a stepwise approach, it has similar rates of composite endpoints technical success and device success as well as long-term mortality.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Estudos Retrospectivos , Volume Sistólico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Função Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
6.
Clin Res Cardiol ; 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38078955

RESUMO

BACKGROUND: Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) is a viable alternative to redo surgery in selected patients with bioprosthetic valve dysfunction. Most ViV-TAVI procedures have been performed in stented bioprosthetic valves (ST); stentless bioprostheses (SL) lack fluoroscopic markers and could be more challenging for ViV-TAVI. Data on more recent patients applying Valve Academic Research Consortium (VARC)-3 defined outcomes are scarce. We compared patient characteristics, procedural outcomes, and 5-year mortality of patients with SL versus ST aortic bioprosthetic valve failure undergoing ViV-TAVI. METHODS: Patients undergoing ViV-TAVI between 2007 and 2022 (52.5% of cases after 2015) at 3 German centers were included in this analysis. The co-primary outcome measures were technical success, device success, and early safety defined by VARC-3. Mortality was assessed up to 5 years. RESULTS: Overall, 43 (11.8%) SL and 313 (88.2%) ST ViV-TAVI were included. Patients were comparable with regard to age, sex, clinically relevant baseline comorbidities, and surgical risk. Technical success (SL: 83.7% versus ST: 79.9%, p = 0.552), device success (SL: 67.4% versus ST: 54.3%, p = 0.105), and early safety (SL: 74.4% versus ST: 66.5%, p = 0.296) were comparable between groups. The 30-day mortality (SL: 7.0% versus ST: 2.6%, p = 0.136) and 5-year mortality rates (SL: 23.3% versus ST: 24.6%, p = 0.874) were not significantly different between groups. CONCLUSION: SL and ST ViV-TAVI led to comparable short-term outcomes according to VARC-3- defined endpoints and similar mortality rates up to 5 years of follow-up. VARC-3 defined technical success, device success, and early safety as well as 5-year all-cause mortality in patients undergoing valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) into stentless (SL) compared with stented (ST) failed aortic bioprostheses.

7.
Catheter Cardiovasc Interv ; 102(7): 1311-1316, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37890001

RESUMO

BACKGROUND: Vascular complications following transfemoral TAVR are associated with increased morbidity and mortality. Measures that may mitigate this risk are important. AIM: To evaluate the utility of routine, access-vessel angiography post sheath-removal in the detection and management of complications in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS: This was a retrospective study of 512 consecutive patients who underwent transfemoral TAVR with routine post access-closure angiography from the radial artery. Rates of mild angiographically evident bleeding, bleeding requiring surgery/interventional-radiology, ischemia, 90-day access-site-related events, and major and minor vascular complications using Valve Academic Research Consortium 3 definitions were recorded. RESULTS: Of 512 patients, digital subtraction angiography (DSA) was undertaken via the radial artery in 467 patients (91%). In the remaining patients (9%) DSA was either not attempted, due to concerns regarding kidney disease and contrast volume, or failed due to anatomical factors (aortic tortuosity/calcification). Significant chronic kidney disease was present at baseline in 72.4% of this cohort (stages III-IV or dialysis). Ninety-four percent of cases underwent TAVR using a balloon-expandable platform. Mild iliofemoral extravasation was observed in 7.7% of the DSA cases. These cases were managed by manual compression with none requiring any vascular intervention subsequently. Valve Academic Research Consortium 3 major and minor access-site-related complications were observed in 0.4% and 12.2%, respectively. Access-site-related bleeding and ischemic events requiring interventional-radiology or vascular-surgery were observed in 0.9% and 1.7% of the DSA cases, respectively. No new renal replacement therapy was needed in any of the DSA cases. Discharge to 90-day access-related complications was 0.8%. CONCLUSIONS: Routine post access-closure angiography is feasible via the radial artery in patients undergoing transfemoral TAVR and appears safe. It facilitates early identification of complications and mitigates risk by enabling prompt action to be taken. Larger studies are needed to confirm these findings.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Fatores de Risco , Artéria Femoral , Resultado do Tratamento , Hemorragia/etiologia , Angiografia Digital/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
8.
JACC Cardiovasc Interv ; 16(18): 2262-2274, 2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37676226

RESUMO

BACKGROUND: The updated Valve Academic Research Consortium (VARC) definition for bleeding events after transcatheter aortic valve replacement (TAVR) lacks of clinical validation. OBJECTIVES: The aim of this study was to determine the incidence, predictors, and clinical impact of bleeding events following TAVR as defined by recent VARC-3 criteria. METHODS: A total of 2,384 consecutive patients with severe symptomatic aortic stenosis undergoing TAVR were included. Early (at index hospitalization) and late (after hospital discharge) bleeding complications were defined according to VARC-3 criteria as type 1, 2, 3, or 4. Baseline, procedural, and follow-up (24 [IQR: 12-43] months) data were prospectively collected. RESULTS: Bleeding events occurred in 761 patients (31.9%): types 1, 2, 3, and 4 in 169 (22.2%), 399 (52.4%), 149 (19.6%), and 44 (5.8%) patients, respectively. The primary vascular access site and gastrointestinal locations were the most common bleeding sources among early and late bleeding events, respectively. Female sex, thoracotomy access, larger (14-F) sheath use, and dual antiplatelet therapy determined an increased risk of early bleeding events (P < 0.02 for all). The use of the radial artery for secondary access was associated with a significant risk reduction of early bleeding (P < 0.001). Type 2 and type 3 events were associated with an increased mortality risk at 30-day (HR: 2.94 [95% CI: 1.43-6.03; P = 0.003] and HR: 4.91 [95% CI: 2.19-11.03; P < 0.001], respectively) and 1-year (HR: 1.86 [95% CI: 1.28-2.69; P = 0.001] and HR: 2.28 [95% CI: 1.41-3.66; P = 0.001], respectively) follow-up. A similar prognostic pattern was observed when applying VARC-2 criteria but with a much lower global incidence of early bleeding events (19% vs 27%; P < 0.001). CONCLUSIONS: Bleeding events after TAVR were associated with poorer short- and long-term survival. The magnitude of this correlation was proportional to bleeding severity defined according to VARC-3 criteria. Further studies on bleeding prevention following TAVR are warranted to improve procedural safety and patient prognosis.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Prognóstico , Incidência , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Medição de Risco , Hemorragia/epidemiologia , Hemorragia/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
9.
J Clin Med ; 12(16)2023 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-37629415

RESUMO

Significant progress has been made in both valves and delivery systems (DSs) for transcatheter aortic valve replacement (TAVR) procedures. We aimed to present one-year real-life data regarding TAVR procedures using Portico transcatheter heart valves (THVs) with new-generation, low-profile FlexNav DSs. This retrospective, single-center study enrolled 169 consecutive patients (mean age: 75.8 years, 68% females) with severe aortic stenosis undergoing TAVR with Portico THVs and FlexNav DSs between 2020 and 2021. We evaluated safety and efficacy outcomes, following the VARC-3 consensus, periprocedurally and at 30 days and 1 year. Procedural success was observed in 95.9% of cases, and no procedural mortality occurred. At 30 days, the rates of all-cause mortality, cardiovascular mortality, and neurological events were 4.7%, 3.6%, and 3.0%, respectively. Additionally, major vascular complications, acute kidney injury, and bleeding were recorded at rates of 11.2%, 14.8%, and 7.7%, respectively. The 1-year data showed all-cause mortality, cardiovascular mortality, and neurological event rates of 10.7%, 8.3%, and 7.7%, respectively. The moderate paravalvular leak and permanent pacemaker rates at 1 year were 2.6% and 12.2%, respectively. This real-life data provided evidence of positive outcomes and high technical success with Portico THVs and FlexNav DSs. Furthermore, we found low rates of mortality and neurological events, with satisfactory hemodynamic and functional results.

10.
Front Cardiovasc Med ; 10: 1130627, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37089885

RESUMO

Backgrounds: The vascular closure device (VCD) is a medical device used for achieving hemostasis of vascular access sites greater than 8 Fr. We compared complications after placement of Perclose ProGlide (Abbott Vascular, USA), a percutaneous suture-mediated closure system, with MANTA VCD (Teleflex Vascular, USA), a collagen-based closure device. Methods: This retrospective cohort study analyzed procedures performed between 2016 and 2021. We compared the incidence of bleeding complications according to the Bleeding Academic Research Consortium (BARC) and Valve Academic Research Consortium-3 (VARC-3) criteria. The comparison was made between two cohorts of patients: in the first, vascular access sites were closed with a double Perclose ProGlide system, and in the second with an 18 Fr MANTA VCD. Results: A total of 189 patients were included in the study, out of which 63% were male and 37% were female, with a median age of 79 (72-83) years. All devices were used for femoral arterial access closure. A double Perclose ProGlide was used in 91 (48%) patients, while MANTA VCD was used in 98 patients (52%). The distribution of patients by VARC-3 and BARC bleeding criteria differs between groups (p = 0.017). A significantly higher incidence of VARC 1 (14% vs. 4%; p = 0.020) and BARC 1-2 (14% vs. 4%; p = 0.020) complications in the Perclose ProGlide cohort was observed. VARC 3 (1% vs. 5%; p = 0.213) and BARC 3b (1% vs. 5%; p = 0.213) complications showed higher, but statistically non-significant rates of major bleeding complications in the MANTA VCD cohort. The need for subsequent surgical revision did not show a significant difference between the cohorts (2% vs. 6%; p = 0.281). Conclusion: The Perclose ProGlide cohort was associated with a significantly higher rate of milder complications. MANTA VCD cohort had a higher rate of major bleeding complications, requiring more complex treatment with a potentially larger impact on quality of life.

11.
Rev Esp Cardiol (Engl Ed) ; 76(11): 872-880, 2023 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36898524

RESUMO

INTRODUCTION AND OBJECTIVES: No comparisons have been published yet regarding the newest iteration of balloon- and self-expandable transcatheter heart valves for the treatment of bicuspid aortic valve (BAV) stenosis. METHODS: Multicenter registry of consecutive patients with severe BAV stenosis treated with balloon-expandable transcatheter heart valves (Myval and SAPIEN 3 Ultra, S3U) or self-expanding Evolut PRO+(EP+). TriMatch analysis was carried out to minimize the impact of baseline differences. The primary endpoint of the study was 30-day device success, and the secondary endpoints were the composite and individual components of early safety at 30 days. RESULTS: A total of 360 patients (age 76.6±7.6 years, 71.9% males) were included: 122 Myval (33.9%), 129 S3U (35.8%), and 109 EP+(30.3%). The mean STS score was 3.6±1.9%. There were no cases of coronary artery occlusion, annulus rupture, aortic dissection, or procedural death. The primary endpoint of device success at 30 days was significantly higher in the Myval group (Myval: 100%; S3U: 87.5%; and EP+: 81.3%), mainly due to higher residual aortic gradients with S3U and greater≥moderate aortic regurgitation (AR) with EP+. No significant differences were found in the unadjusted rate of pacemaker implantation. CONCLUSIONS: In patients with BAV stenosis deemed unsuitable for surgery, Myval, S3U and EP+showed similar safety but balloon-expandable Myval had better gradients than S3U, and both balloon-expandable devices had lower residual AR than EP+, suggesting that, taking into consideration the patient-specific risks, any of these devices can be selected with optimal outcomes.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Desenho de Prótese
12.
Artigo em Inglês | MEDLINE | ID: mdl-36858846

RESUMO

OBJECTIVE: To assess the mid-term clinical outcomes, hemodynamics, left ventricular (LV) mass regression, and structural valve deterioration (SVD) in patients implanted with the Perceval aortic sutureless valve across valve sizes. METHODS: Data were obtained from a multicenter European trial and a US Investigational Device Exemption trial. Echocardiography data were analyzed by an echocardiography core lab. A mixed-effects regression model was used to assess relationships between hemodynamic outcomes, time from the procedure, and valve sizes. The Valve Academic Research Consortium (VARC)-3 definition for bioprosthetic valve failure was applied. RESULTS: A Perceval sutureless valve was implanted in 970 patients. The median patient age was 77.8 years, 57.2% were female, the median Society of Thoracic Surgeons predicated risk of mortality was 3.3% (range, 2.1%-6.2%), and 33.4% had a concomitant procedure. The median clinical follow-up was 45.7 months (range, 28.2-76.1 months). Small and medium valves were implanted more commonly in women than in men (16.9% vs 1.9% for small and 55.1% vs 19.5% for medium; P < .001). The mean aortic valve gradients decreased significantly postimplantation and remained stable across all valve sizes throughout the follow-up period. All patients were free from severe patient-prosthesis mismatch (with an effective orifice area/m2 of >0.8). Significant LV mass regression was documented regardless valve sizes, plateaued at -9.1% at 5 years. Freedom from SVD and reintervention were 95.2% and 96.3%, respectively, at 5 years and were independent of implanted valve size (P = .22). The VARC-3 stage 3 bioprosthetic valve failure rate was low, 2.8% at 5 years. CONCLUSIONS: The Perceval valve demonstrated low and stable mean gradients, significant LV mass regression, and low SVD and reintervention rates across all valve sizes.

13.
Int J Cardiol ; 371: 299-304, 2023 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-36306951

RESUMO

BACKGROUND: Normal-flow (stroke volume index, SVi >35 ml/m2) low-gradient (dPmean <40 mmHg) aortic stenosis (NFLG-AS) is subject of scientific debate. Guidelines fail to give conclusive treatment recommendations. We hypothesized that NFLG patients are heterogenous, containing a subgroup similar to high-gradient aortic stenosis patients (dPmean ≥40 mmHg, HG-AS) concerning characteristics and outcomes. METHODS: 2326 patients undergoing transcatheter aortic valve replacement (TAVI) at our centre between 2013 and 2019 were analysed. 386 patients fulfilled criteria of NFLG-AS. Their median dPmean was 33 mmHg, which was used for grouping (204 patients with higher gradient NFLG-AS, 186 patients with lower gradient NFLG-AS). They were compared to 956 HG-AS patients. RESULTS: Characteristics of lower gradient NFLG-AS patients differed from HG-AS patients in many aspects while higher gradient NFLG-AS and HG-AS patients were mostly similar, underscored by higher Society of Thoracic Surgeons scores in lower gradient NFLG-AS (lower gradient NFLG-AS, 3.9, HG-AS, 3.0, p = 0.03, higher gradient NFLG-AS, 3.0, p = 0.04). Procedural complications were comparable. Estimated 3-year all-cause mortality was higher in lower gradient NFLG-AS compared to HG-AS patients (hazard ratio 1.7, p < 0.01), whereas mortality of higher gradient NFLG-AS was similar to HG-AS patients (hazard ratio 1.2, p = 0.31). Cardiovascular mortality was highest among lower gradient NFLG-AS patients (21.6% vs. higher gradient NFLG-AS, 15.4%, vs. HG-AS, 11.1%, p < 0.01). CONCLUSIONS: NFLG-AS patients are indeed heterogenous. NFLG-AS patients with higher gradients resemble HG-AS patients in clinical characteristics and outcomes and should not be treated differently. Lower gradient NFLG-AS patients have increased long-term mortality and the use of TAVI requires careful consideration.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Função Ventricular Esquerda , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Índice de Gravidade de Doença
14.
Acta Cardiol ; 77(10): 960-969, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36326198

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been adopted as an alternative to surgery in severe aortic stenosis treatment, even in low-intermediate risk. The aim of this study is to retrospectively report our single-centre 13-year TAVI experience with emphasis on learning curve, referral indication and trends in outcomes over time. METHODS: We included 361 consecutive patients who underwent TAVI from January 2008 to December 2020, grouped according to similar per-year volume of procedures: G1 (2008-2014), G2 (2015-2017) and G3 (2018-2020). RESULTS: The number of procedures increased (group size: 59 vs. 106 vs. 196). No major differences were observed in STS-PROM and EuroSCORE-II between groups, despite TAVI in patients with prior surgical revascularisation was mainly performed in G1. Trans-femoral approach raised from 80.8 to 93.4%, while the most common alternative access was trans-subclavian. The pre-dilation rate was higher in G1 with lower prosthesis post-dilation rate. The length of hospital stay decreased in time by 30%. At 30 days a reduction in all-cause mortality, vascular complications, bleedings and para-valvular leak combined with higher rate of permanent pacing were observed over the groups. At 1-year there was no difference in all-cause mortality but over 30% reduction in cardiovascular death (8.5 vs. 7.5 vs. 5.6%). CONCLUSIONS: Favourable trends were observed across the groups, with an improvement in periprocedural outcomes and cardiovascular mortality at 1-year. These improvements could depend on increased expertise because mortality reduction was noted only after reaching a significant procedure volume. A trend towards lower risk patients selection was present in our cohort, as previously described worldwide.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Bélgica/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos
15.
JTCVS Open ; 11: 72-80, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36172410

RESUMO

Objectives: The Carpentier-Edwards Perimount Magna Ease (Edwards Lifesciences) pericardial bioprosthesis has demonstrated satisfying hemodynamics at midterm follow-up, but its durability remains unclear. We report our 10-year experience with this third-generation valve implanted in the aortic position, with particular attention to structural valve deterioration. Methods: From 2007 to 2016 at our center, 338 patients underwent aortic valve replacement using the Perimount Magna Ease pericardial bioprosthesis. Patients were prospectively followed (mean 6.6 ± 2.6 years) with clinical evaluation and yearly echocardiography. Follow-up was 98% complete (7 patients lost) for a total of 2238 valve-years. Bioprosthesis structural valve deterioration was determined by strict echocardiographic assessment based on the Valve Academic Research Consortium 3 criteria. Results: Overall operative mortality was 1.2%. Actuarial survival including early deaths averaged 80.9% ± 2.2% and 66.7% ± 4.4% after 5 and 10 years of follow-up, respectively. Actuarial freedom from explantation due to structural valve deterioration at 5 and 10 years was 99.6% ± 0.4% and 88.8% ± 5.0%, respectively, and actuarial freedom of structural valve deterioration at 5 and 10 years was 98.5% ± 0.7% and 44.0% ± 6.4%, respectively. More precisely, actuarial freedom of structural valve deterioration stage 3 was 99.6% ± 0.4% at 5 years and 88.3% ± 5.0% at 10 years, whereas freedom of structural valve deterioration stage 2/3 was 98.5% ± 0.7% and 60.9% ± 7.0%, respectively. Conclusions: With a low rate of explantation due to structural valve deterioration events at 10 years, and particularly a low rate of moderate or severe structural valve deterioration based on echocardiographic Valve Academic Research Consortium 3 criteria, the Carpentier-Edwards Perimount Magna Ease pericardial bioprosthesis remains a reliable choice for a tissue valve in the aortic position.

16.
J Cardiovasc Comput Tomogr ; 16(5): 423-430, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35637128

RESUMO

BACKGROUND: Computed tomography (CT) imaging is the standard of care before transcatheter aortic valve replacement (TAVR). The aortic annulus undergoes conformational changes during the heart cycle. Therefore, the image acquisition time point can impact prosthesis sizing and fit. Clinical outcome data are lacking. The aim of this study was to compare systolic and diastolic cardiac CT data acquisition with regard to procedural and clinical outcomes in patients undergoing TAVR for severe aortic stenosis (AS). METHODS: Preprocedural high-pitch helical CT datasets were analyzed in 1954 patients undergoing TAVR between 2013 and 2018 â€‹at our center. Patients were stratified into two groups according to the acquisition heart phase (979 systolic and 975 diastolic). The study was approved by the local ethics committee. RESULTS: Median age was 81.6 [interquartile range 77.5-85.8] years and 964 (49.3%) patients were male. No significant difference was found for the Valve Academic Research Consortium-3 (VARC-3) endpoints of technical failure (systolic, 5.1% vs. diastolic, 5.2%, p â€‹= â€‹0.94) or device failure (systolic, 13.7% vs. diastolic, 13.5%, p â€‹= â€‹0.92). There was no difference in paravalvular regurgitation. All-cause 30-day mortality was comparable (systolic, 3.6% [95% confidence interval, 2.4-4.7%] vs. diastolic, 3.6% [2.4-4.8%], p â€‹= â€‹1.00), while 3-year mortality rates were higher in the diastolic group (Society of Thoracic Surgeons score adjusted hazard ratio, 1.25 [1.07-1.46], p â€‹< â€‹0.01). CONCLUSIONS: While the 30-day technical and clinical outcomes after TAVR are comparable between systolic and diastolic CT imaging, diastolic imaging was associated with higher long-term mortality. Therefore, the data support the guideline recommendation of systolic imaging.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Sopros Cardíacos/etiologia , Humanos , Masculino , Valor Preditivo dos Testes , Fatores de Risco , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
17.
Clin Res Cardiol ; 111(12): 1325-1335, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35320407

RESUMO

OBJECTIVES: The study objective was to characterize different groups of low-flow low-gradient (LFLG) aortic stenosis (AS) and determine short-term outcomes and long-term mortality according to Valve Academic Research Consortium-3 (VARC-3) endpoint definitions. BACKGROUND: Characteristics and outcomes of patients with LFLG AS undergoing transcatheter aortic valve implantation (TAVI) are poorly understood. METHODS: All patients undergoing TAVI at our center between 2013 and 2019 were screened. Patients were divided into three groups according to mean pressure gradient (dPmean), ejection fraction (LVEF), and stroke volume index (SVi): high gradient (HG) AS (dPmean ≥ 40 mmHg), classical LFLG (cLFLG) AS (dPmean < 40 mmHg, LVEF < 50%), and paradoxical LFLG (pLFLG) AS (dPmean < 40 mmHg, LVEF ≥ 50%, SVi ≤ 35 ml/m2). RESULTS: We included 1776 patients (956 HG, 447 cLFLG, and 373 pLFLG patients). Most baseline characteristics differed significantly. Median Society of Thoracic Surgeons (STS) score was highest in cLFLG, followed by pLFLG and HG patients (5.0, 3.9 and 3.0, respectively, p < 0.01). Compared to HG patients, odds ratios for the short-term VARC-3 composite endpoints, technical failure (cLFLG, 0.76 [95% confidence interval, 0.40-1.36], pLFLG, 1.37 [0.79-2.31]) and device failure (cLFLG, 1.06 [0.74-1.49], pLFLG, 0.97 [0.66-1.41]) were similar, without relevant differences within LFLG patients. NYHA classes improved equally in all groups. Compared to HG, LFLG patients had a higher 3-year all-cause mortality (STS score-adjusted hazard ratios, cLFLG 2.16 [1.77-2.64], pLFLG 1.53 [1.22-193]), as well as cardiovascular mortality (cLFLG, 2.88 [2.15-3.84], pLFLG, 2.08 [1.50-2.87]). CONCLUSIONS: While 3-year mortality remains high after TAVI in LFLG compared to HG patients, symptoms improve in all subsets after TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Índice de Gravidade de Doença , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA