Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
EJNMMI Res ; 14(1): 24, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38436824

RESUMO

BACKGROUND: Correct classification of estrogen receptor (ER) status is essential for prognosis and treatment planning in patients with breast cancer (BC). Therefore, it is recommended to sample tumor tissue from an accessible metastasis. However, ER expression can show intra- and intertumoral heterogeneity. 16α-[18F]fluoroestradiol ([18F]FES) Positron Emission Tomography/Computed Tomography (PET/CT) allows noninvasive whole-body (WB) identification of ER distribution and is usually performed as a single static image 60 min after radiotracer injection. Using dynamic whole-body (D-WB) PET imaging, we examine [18F]FES kinetics and explore whether Patlak parametric images ( K i ) are quantitative and improve lesion visibility. RESULTS: This prospective study included eight patients with metastatic ER-positive BC scanned using a D-WB PET acquisition protocol. The kinetics of [18F]FES were best characterized by the irreversible two-tissue compartment model in tumor lesions and in the majority of organ tissues. K i values from Patlak parametric images correlated with K i values from the full kinetic analysis, r2 = 0.77, and with the semiquantitative mean standardized uptake value (SUVmean), r2 = 0.91. Furthermore, parametric K i images had the highest target-to-background ratio (TBR) in 162/164 metastatic lesions and the highest contrast-to-noise ratio (CNR) in 99/164 lesions compared to conventional SUV images. TBR was 2.45 (95% confidence interval (CI): 2.25-2.68) and CNR 1.17 (95% CI: 1.08-1.26) times higher in K i images compared to SUV images. These quantitative differences were seen as reduced background activity in the K i images. CONCLUSION: [18F]FES uptake is best described by an irreversible two-tissue compartment model. D-WB [18F]FES PET/CT scans can be used for direct reconstruction of parametric K i images, with superior lesion visibility and K i values comparable to K i values found from full kinetic analyses. This may aid correct ER classification and treatment decisions. Trial registration ClinicalTrials.gov: NCT04150731, https://clinicaltrials.gov/study/NCT04150731.

2.
Eur J Nucl Med Mol Imaging ; 51(7): 2100-2113, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38347299

RESUMO

PURPOSE: Evaluation of 90Y liver radioembolization post-treatment clinical data using a whole-body Biograph Vision Quadra PET/CT to investigate the potential of protocol optimization in terms of scan time and dosimetry. METHODS: 17 patients with hepatocellular carcinoma with median (IQR) injected activity 2393 (1348-3298) MBq were included. Pre-treatment dosimetry plan was based on 99mTc-MAA SPECT/CT with Simplicit90Y™ and post-treatment validation with Quadra using Simplicit90Y™ and HERMIA independently. Regarding the image analysis, mean and peak SNR, the coefficient of variation (COV) and lesion-to-background ratio (LBR) were evaluated. For the post-treatment dosimetry validation, the mean tumor, whole liver and lung absorbed dose evaluation was performed using Simplicit90Y and HERMES. Images were reconstructed with 20-, 15-, 10-, 5- and 1- min sinograms with 2, 4, 6 and 8 iterations. Wilcoxon signed rank test was used to show statistical significance (p < 0.05). RESULTS: There was no difference of statistical significance between 20- and 5- min reconstructed times for the peak SNR, COV and LBR. In addition, there was no difference of statistical significance between 20- and 1- min reconstructed times for all dosimetry metrics. Lung dosimetry showed consistently lower values than the expected. Tumor absorbed dose based on Simplicit90Y™ was similar to the expected while HERMES consistently underestimated significantly the measured tumor absorbed dose. Finally, there was no difference of statistical significance between expected and measured tumor, whole liver and lung dose for all reconstruction times. CONCLUSION: In this study we evaluated, in terms of image quality and dosimetry, whole-body PET clinical images of patients after having been treated with 90Y microspheres radioembolization for liver cancer. Compared to the 20-min standard scan, the simulated 5-min reconstructed images provided equal image peak SNR and noise behavior, while performing also similarly for post-treatment dosimetry of tumor, whole liver and lung absorbed doses.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Fígado , Pulmão , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radioisótopos de Ítrio , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Radioisótopos de Ítrio/uso terapêutico , Feminino , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Embolização Terapêutica/métodos , Pessoa de Meia-Idade , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Pulmão/diagnóstico por imagem , Pulmão/efeitos da radiação , Fígado/diagnóstico por imagem , Radiometria/métodos , Imagem Corporal Total/métodos
3.
Eur J Nucl Med Mol Imaging ; 51(7): 2036-2046, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38383743

RESUMO

PURPOSE: High blood glucose (hBG) in patients undergoing [18F]FDG PET/CT scans often results in rescheduling the examination, which may lead to clinical delay for the patient and decrease productivity for the department. The aim of this study was to evaluate whether long-axial field-of-view (LAFOV) PET/CT can minimize the effect of altered bio-distribution in hBG patients and is able to provide diagnostic image quality in hBG situations. MATERIALS AND METHODS: Oncologic patients with elevated blood glucose (≥ 8.0 mmol/l) and normal blood glucose (< 8.0 mmol/l, nBG) levels were matched for tumor entity, gender, age, and BMI. hBG patients were further subdivided into two groups (BG 8-11 mmol/l and BG > 11 mmol/l). Tracer uptake in the liver, muscle, and tumor was evaluated. Furthermore, image quality was compared between long acquisitions (ultra-high sensitivity mode, 360 s) on a LAFOV PET/CT and routine acquisitions equivalent to a short-axial field-of-view scanner (simulated (sSAFOV), obtained with high sensitivity mode, 120 s). Tumor-to-background ratio (TBR) and contrast-to-noise ratio (CNR) were used as the main image quality criteria. RESULTS: Thirty-one hBG patients met the inclusion criteria and were matched with 31 nBG patients. Overall, liver uptake was significantly higher in hBG patients (SUVmean, 3.07 ± 0.41 vs. 2.37 ± 0.33; p = 0.03), and brain uptake was significantly lower (SUVmax, 7.58 ± 0.74 vs. 13.38 ± 3.94; p < 0.001), whereas muscle (shoulder/gluteal) uptake showed no statistically significant difference. Tumor uptake was lower in hBG patients, resulting in a significantly lower TBR in the hBG cohort (3.48 ± 0.74 vs. 5.29 ± 1.48, p < 0.001). CNR was higher in nBG compared to hBG patients (12.17 ± 4.86 vs. 23.31 ± 12.22, p < 0.001). However, subgroup analysis of nBG 8-11 mmol/l on sSAFOV PET/CT compared to hBG (> 11 mmol/l) patients examined with LAFOV PET/CT showed no statistical significant difference in CNR (19.84 ± 8.40 vs. 17.79 ± 9.3, p = 0.08). CONCLUSION: While elevated blood glucose (> 11 mmol) negatively affected TBR and CNR in our cohort, the images from a LAFOV PET-scanner had comparable CNR to PET-images acquired from nBG patients using sSAFOV PET/CT. Therefore, we argue that oncologic patients with increased blood sugar levels might be imaged safely with LAFOV PET/CT when rescheduling is not feasible.


Assuntos
Glicemia , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Glicemia/análise , Análise por Pareamento , Neoplasias/diagnóstico por imagem , Adulto , Compostos Radiofarmacêuticos/farmacocinética
4.
Eur J Nucl Med Mol Imaging ; 51(7): 2137-2150, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38286936

RESUMO

AIM: In addition to significant improvements in sensitivity and image quality, the recent introduction of long axial field-of-view (LAFOV) PET/CT scanners has enabled dynamic whole-body imaging for the first time. We aim herein to determine an appropriate acquisition time range for static low-dose [18F]PSMA-1007 PET imaging and to investigate the whole-body pharmacokinetics of [18F]PSMA-1007 by dynamic PET with the LAFOV Biograph Vision Quadra PET/CT in a group of prostate cancer patients. METHODOLOGY: In total, 38 prostate cancer patients were enrolled in the analysis for staging or re-staging purposes. Thirty-four patients underwent dynamic whole-body PET/CT (60 min) followed by static whole-body PET/CT and four patients underwent static whole-body PET/CT only. The activity applied was 2 MBq/kg [18F]PSMA-1007. The static PET images of 10-min duration (PET-10) were reconstructed and further split into 8-min (PET-8), 6-min (PET-6), 5-min (PET-5), 4-min (PET-4), and 2-min (PET-2) duration groups. Comparisons were made between the different reconstructed scan times in terms of lesion detection rate and image quality based on SUV calculations of tumor lesions and the spleen, which served as background. Analysis of the dynamic PET/CT data was based on a two-tissue compartment model using an image-derived input function obtained from the descending aorta. RESULTS: Analysis of lesion detection rate showed no significant differences when reducing PET acquisitions from 10 up to 5 min. In particular, a total of 169 lesions were counted with PET-10, and the corresponding lesion detection rates (95% CI for the 90% quantile of the differences in tumor lesions) for shorter acquisitions were 100% (169/169) for PET-8 (95% CI: 0-0), 98.8% (167/169) for PET-6 (95% CI: 0-1), 95.9% (162/169) for PET-5 (95% CI: 0-3), 91.7% (155/169) for PET-4 (95% CI: 1-2), and 85.2% (144/169) for PET-2 (95% CI: 1-6). With the exception of PET-2, the differences observed between PET-10 and the other shorter acquisition protocols would have no impact on any patient in terms of clinical management. Objective evaluation of PET/CT image quality showed no significant decrease in tumor-to-background ratio (TBR) with shorter acquisition times, despite a gradual decrease in signal-to-noise ratio (SNR) in the spleen. Whole-body quantitative [18F]PSMA-1007 pharmacokinetic analysis acquired with full dynamic PET scanning was feasible in all patients. Two-tissue compartment modeling revealed significantly higher values for the parameter k3 in tumor lesions and parotid gland compared to liver and spleen, reflecting a higher specific tracer binding to the PSMA molecule and internalization rate in these tissues, a finding also supported by the respective time-activity curves. Furthermore, correlation analysis demonstrated a significantly strong positive correlation (r = 0.72) between SUV and k3 in tumor lesions. CONCLUSIONS: In prostate cancer, low-dose (2 MBq/kg) [18F]PSMA-1007 LAFOV PET/CT can reduce static scan time by 50% without significantly compromising lesion detection rate and objective image quality. In addition, dynamic PET can elucidate molecular pathways related to the physiology of [18F]PSMA-1007 in both tumor lesions and normal organs at the whole-body level. These findings unfold many of the potentials of the new LAFOV PET/CT technology in the field of PSMA-based diagnosis and theranostics of prostate cancer.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Imagem Corporal Total , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/metabolismo , Idoso , Pessoa de Meia-Idade , Niacinamida/análogos & derivados , Niacinamida/farmacocinética , Oligopeptídeos/farmacocinética , Radioisótopos de Flúor/farmacocinética , Idoso de 80 Anos ou mais , Doses de Radiação , Compostos Radiofarmacêuticos/farmacocinética
5.
Eur J Nucl Med Mol Imaging ; 51(2): 422-433, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37740742

RESUMO

PURPOSE: Inflamed, prone-to-rupture coronary plaques are an important cause of myocardial infarction and their early identification is crucial. Atherosclerotic plaques are characterized by overexpression of the type-2 somatostatin receptor (SST2) in activated macrophages. SST2 ligand imaging (e.g. with [68 Ga]Ga-DOTA-TOC) has shown promise in detecting and quantifying the inflammatory activity within atherosclerotic plaques. However, the sensitivity of standard axial field of view (SAFOV) PET scanners may be suboptimal for imaging coronary arteries. Long-axial field of view (LAFOV) PET/CT scanners may help overcome this limitation. We aim to assess the ability of [68 Ga]Ga-DOTA-TOC LAFOV-PET/CT in detecting calcified, SST2 overexpressing coronary artery plaques. METHODS: In this retrospective study, 108 oncological patients underwent [68 Ga]Ga-DOTA-TOC PET/CT on a LAFOV system. [68 Ga]Ga-DOTA-TOC uptake and calcifications in the coronary arteries were evaluated visually and semi-quantitatively. Data on patients' cardiac risk factors and coronary artery calcium score were also collected. Patients were followed up for 21.5 ± 3.4 months. RESULTS: A total of 66 patients (61.1%) presented with calcified coronary artery plaques. Of these, 32 patients had increased [68 Ga]Ga-DOTA-TOC uptake in at least one coronary vessel (TBR: 1.65 ± 0.53). Patients with single-vessel calcifications showed statistically significantly lower uptake (SUVmax 1.10 ± 0.28) compared to patients with two- (SUVmax 1.31 ± 0.29, p < 0.01) or three-vessel calcifications (SUVmax 1.24 ± 0.33, p < 0.01). There was a correlation between coronary artery calcium score (CACS) and [68 Ga]Ga-DOTA-TOC uptake, especially in the LAD (p = 0.02). Stroke and all-cause death occurred more frequently in patients with increased [68 Ga]Ga-DOTA-TOC uptake (15.63% vs. 0%; p:0.001 and 21.88% vs. 6.58%; p: 0.04, respectively) during the follow-up period. CONCLUSION: [68 Ga]Ga-DOTA-TOC as a marker for the macrophage activity can reveal unknown cases of inflamed calcified coronary artery plaques using a LAFOV PET system. [68 Ga]Ga-DOTA-TOC uptake increased with the degree of calcification and correlated with higher risk of stroke and all-cause death. [68 Ga]Ga-DOTA-TOC LAFOV PET/CT may be useful to assess patients' cardiovascular risk.


Assuntos
Compostos Organometálicos , Placa Aterosclerótica , Acidente Vascular Cerebral , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Octreotida , Estudos Retrospectivos , Cálcio , Placa Aterosclerótica/diagnóstico por imagem , Inflamação/diagnóstico por imagem
6.
Biomed Eng Online ; 22(1): 110, 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38007471

RESUMO

BACKGROUND: Tumor heterogeneity is recognized as a predictor of treatment response and patient outcome. Quantification of tumor heterogeneity across all scales may therefore provide critical insight that ultimately improves cancer management. METHODS: An image registration-based framework for the study of tumor heterogeneity in whole-body images was evaluated on a dataset of 490 FDG-PET-CT images of lung cancer, lymphoma, and melanoma patients. Voxel-, lesion- and subject-level features were extracted from the subjects' segmented lesion masks and mapped to female and male template spaces for voxel-wise analysis. Resulting lesion feature maps of the three subsets of cancer patients were studied visually and quantitatively. Lesion volumes and lesion distances in subject spaces were compared with resulting properties in template space. The strength of the association between subject and template space for these properties was evaluated with Pearson's correlation coefficient. RESULTS: Spatial heterogeneity in terms of lesion frequency distribution in the body, metabolic activity, and lesion volume was seen between the three subsets of cancer patients. Lesion feature maps showed anatomical locations with low versus high mean feature value among lesions sampled in space and also highlighted sites with high variation between lesions in each cancer subset. Spatial properties of the lesion masks in subject space correlated strongly with the same properties measured in template space (lesion volume, R = 0.986, p < 0.001; total metabolic volume, R = 0.988, p < 0.001; maximum within-patient lesion distance, R = 0.997, p < 0.001). Lesion volume and total metabolic volume increased on average from subject to template space (lesion volume, 3.1 ± 52 ml; total metabolic volume, 53.9 ± 229 ml). Pair-wise lesion distance decreased on average by 0.1 ± 1.6 cm and maximum within-patient lesion distance increased on average by 0.5 ± 2.1 cm from subject to template space. CONCLUSIONS: Spatial tumor heterogeneity between subsets of interest in cancer cohorts can successfully be explored in whole-body PET-CT images within the proposed framework. Whole-body studies are, however, especially prone to suffer from regional variation in lesion frequency, and thus statistical power, due to the non-uniform distribution of lesions across a large field of view.


Assuntos
Neoplasias Pulmonares , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Masculino , Feminino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos de Viabilidade , Fluordesoxiglucose F18/metabolismo , Neoplasias Pulmonares/patologia , Tomografia por Emissão de Pósitrons/métodos
7.
Med Phys ; 50(10): 6151-6162, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37134002

RESUMO

BACKGROUND: Whole-body Metabolic Tumor Volume (MTVwb) is an independent prognostic factor for overall survival in lung cancer patients. Automatic segmentation methods have been proposed for MTV calculation. Nevertheless, most of existing methods for patients with lung cancer only segment tumors in the thoracic region. PURPOSE: In this paper, we present a Two-Stage cascaded neural network integrated with Camouflaged Object Detection mEchanisms (TS-Code-Net) for automatic segmenting tumors from whole-body PET/CT images. METHODS: Firstly, tumors are detected from the Maximum Intensity Projection (MIP) images of PET/CT scans, and tumors' approximate localizations along z-axis are identified. Secondly, the segmentations are performed on PET/CT slices that contain tumors identified by the first step. Camouflaged object detection mechanisms are utilized to distinguish the tumors from their surrounding regions that have similar Standard Uptake Values (SUV) and texture appearance. Finally, the TS-Code-Net is trained by minimizing the total loss that incorporates the segmentation accuracy loss and the class imbalance loss. RESULTS: The performance of the TS-Code-Net is tested on a whole-body PET/CT image data-set including 480 Non-Small Cell Lung Cancer (NSCLC) patients with five-fold cross-validation using image segmentation metrics. Our method achieves 0.70, 0.76, and 0.70, for Dice, Sensitivity and Precision, respectively, which demonstrates the superiority of the TS-Code-Net over several existing methods related to metastatic lung cancer segmentation from whole-body PET/CT images. CONCLUSIONS: The proposed TS-Code-Net is effective for whole-body tumor segmentation of PET/CT images. Codes for TS-Code-Net are available at: https://github.com/zyj19/TS-Code-Net.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/patologia , Redes Neurais de Computação , Tronco/patologia , Processamento de Imagem Assistida por Computador/métodos
8.
Ann Nucl Med ; 37(5): 310-315, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36913094

RESUMO

OBJECTIVE: Long axial field-of-view (LAFOV) PET/CT showed improved performance resulting from higher sensitivity. The aim was to quantify the impact of using the full acceptance angle (UHS) in image reconstructions with the Biograph Vision Quadra LAFOV PET/CT (Siemens Healthineers) compared to the limited acceptance angle (high sensitivity mode, HS). METHODS: 38 oncological patients examined on a LAFOV Biograph Vision Quadra PET/CT were analysed. 15 patients underwent [18F]FDG-PET/CT, 15 patients underwent [18F]PSMA-1007 PET/CT, and 8 patients underwent [68Ga]Ga-DOTA-TOC PET/CT. Signal-to-noise ratio (SNR) and standardised uptake values (SUVmean/max/peak) were used to compare UHS and HS with different acquisition times. RESULTS: The SNR was significantly higher for UHS compared to HS over all acquisition times (SNR UHS/HS [18F]FDG: 1.35 ± 0.02, p < 0.001; [18F]PSMA-1007: 1.25 ± 0.02, p < 0.001; [68Ga]Ga-DOTA-TOC: 1.29 ± 0.02, p < 0.001). CONCLUSION: UHS showed significantly higher SNR opening the possibility of halving short acquisition times. This is of advantage in further reduction of whole-body PET/CT acquisition.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radioisótopos de Gálio , Tomografia por Emissão de Pósitrons
9.
Eur J Nucl Med Mol Imaging ; 50(4): 1168-1182, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36504278

RESUMO

PURPOSE: The image quality characteristics of two NEMA phantoms with yttrium-90 (90Y) were evaluated on a long axial field-of-view (AFOV) PET/CT. The purpose was to identify the optimized reconstruction setup for the imaging of patients with hepatocellular carcinoma after 90Y radioembolization. METHODS: Two NEMA phantoms were used, where one had a 1:10 sphere to background activity concentration ratio and the second had cold background. Reconstruction parameters used are as follows: iterations 2 to 8, Gaussian filter 2- to 6-mm full-width-at-half-maximum, reconstruction matrices 440 × 440 and 220 × 220, high sensitivity (HS), and ultra-high sensitivity (UHS) modes. 50-, 40-, 30-, 20-, 10-, and 5-min acquisitions were reconstructed. The measurements included recovery coefficients (RC), signal-to-noise ratio (SNR), background variability, and lung error which measures the residual error in the corrections. Patient data were reconstructed with 20-, 10-, 5-, and 1-min time frames and evaluated in terms of SNR. RESULTS: The RC for the hot phantom was 0.36, 0.45, 0.53, 0.63, 0.68, and 0.84 for the spheres with diameters of 10, 13, 17, 22, 28, and 37 mm, respectively, for UHS 2 iterations, a 220 × 220 matrix, and 50-min acquisition. The RC values did not differ with acquisition times down to 20 min. The SNR was the highest for 2 iterations, measured 11.7, 16.6, 17.6, 19.4, 21.9, and 27.7 while the background variability was the lowest (27.59, 27.08, 27.36, 26.44, 30.11, and 33.51%). The lung error was 18%. For the patient dataset, the SNR was 19%, 20%, 24%, and 31% higher for 2 iterations compared to 4 iterations for 20-, 10-, 5-, and 1-min time frames, respectively. CONCLUSIONS: This study evaluates the NEMA image quality of a long AFOV PET/CT scanner with 90Y. It provides high RC for the smallest sphere compared to other standard AFOV scanners at shorter scan times. The maximum patient SNR was for 2 iterations, 20 min, while 5 min delivers images with acceptable SNR.


Assuntos
Neoplasias Hepáticas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Ítrio/uso terapêutico , Imagens de Fantasmas , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia
11.
Front Immunol ; 13: 1010263, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36439175

RESUMO

There is current need for new approaches to assess/measure organ-level immunoreactivity and ensuing dysfunction in systemic inflammatory response syndrome (SIRS) and sepsis, in order to protect or recover organ function. Using a rat model of systemic sterile inflammatory shock (intravenous LPS administration), we performed PET imaging with a translocator protein (TSPO) tracer, [18F]DPA-714, as a biomarker for reactive immunoreactive changes in the brain and peripheral organs. In vivo dynamic PET/CT scans showed increased [18F]DPA-714 binding in the brain, lungs, liver and bone marrow, 4 hours after LPS injection. Post-LPS mean standard uptake values (SUVmean) at equilibrium were significantly higher in those organs compared to baseline. Changes in spleen [18F]DPA-714 binding were variable but generally decreased after LPS. SUVmean values in all organs, except the spleen, positively correlated with several serum cytokines/chemokines. In vitro measures of TSPO expression and immunofluorescent staining validated the imaging results. Noninvasive molecular imaging with [18F]DPA-714 PET in a rat model of systemic sterile inflammatory shock, along with in vitro measures of TSPO expression, showed brain, liver and lung inflammation, spleen monocytic efflux/lymphocytic activation and suggested increased bone marrow hematopoiesis. TSPO PET imaging can potentially be used to quantify SIRS and sepsis-associated organ-level immunoreactivity and assess the effectiveness of therapeutic and preventative approaches for associated organ failures, in vivo.


Assuntos
Radioisótopos de Flúor , Sepse , Animais , Ratos , Lipopolissacarídeos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos , Proteínas de Transporte/metabolismo , Sepse/diagnóstico por imagem , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico por imagem , Receptores de GABA-A/metabolismo
12.
PET Clin ; 16(1): 129-136, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33218601

RESUMO

Cardiovascular conditions can exist as part of a systemic disorder (eg, sarcoidosis, amyloidosis, or vasculitis) or have systemic consequences as a result of the cardiovascular insult (eg, myocardial infarction). In other circumstances, multisystem evaluation of metabolism and blood flow might be key for evaluation of multisystemic syndromes or conditions. Long axial field-of-view PET/computed tomography systems hold the promise of transforming the investigation of such systemic disorders. This article aims at reviewing some of the potential cardiovascular applications of this novel instrumentation device.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Imagem Corporal Total/métodos , Humanos
13.
Ann Nucl Med ; 34(2): 119-127, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31768819

RESUMO

OBJECTIVE: High-resolution dedicated breast positron emission tomography (dbPET) can visualize breast cancer more clearly than whole-body PET/computed tomography (CT). In Japan, the combined use of dbPET and whole-body PET/CT is necessary in indications for health insurance. Although several clinical studies have compared both devices, a physical evaluation by the phantom test has not been reported. The aim of this study was to compare the ability of ring-shaped dbPET and whole-body PET/CT using a common phantom with reference to the Japanese guideline for the oncology 18F-fluorodeoxyglucose (FDG)-PET/CT data acquisition protocol. METHODS: A cylindrical breast phantom with four spheres of different diameters (16, 10, 7.5, and 5 mm) filled an FDG solution at sphere-to-background radioactivity ratios (SBRs) of 2:1, 4:1, and 8:1 was prepared. Images were then acquired by whole-body PET/CT and subsequently by dbPET. The reconstructed images were visually evaluated and the coefficient of variation and uniformity of the background (CVbackground and SDΔSUVmean), percentages of contrast and background variability (%QH,5mm and %N5mm), and their ratio (%QH,5mm/N5mm), and relative recovery coefficient were compared with the standards defined in the protocol for whole-body PET/CT. RESULTS: The parameters were calculated at an SBR of 8:1, which was the only SBR in which a 5-mm sphere was visible on both devices. The standards were defined as < 10% for CVbackground, ≤ 0.025 for SDΔSUVmean, < 5.6% for %N5mm, > 2.8 for %QH,5mm/N5mm, and > 0.38 for the relative recovery coefficient of the smallest sphere (10 mm in diameter) in the protocol for whole-body PET/CT (the %QH,5mm was not determined for that protocol); the respective values were 6.14%, 0.024, 4.55%, 3.66, and 0.33 for dbPET and 2.21%, 0.021, 3.11%, 1.72, and 0.18 for PET/CT. The QH,5mm was 16.67% for dbPET and 5.34% for PET/CT. The human images also showed higher lesion-to-background contrast on dbPET than on PET/CT despite the noisier background observed with dbPET. CONCLUSION: The common phantom study showed that the background was noisier and that the contrast was much higher in the dbPET image than in the PET/CT image. The acquisition protocol and standards for dbPET will need to be different from those used for whole-body PET/CT.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Fluordesoxiglucose F18/química , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Algoritmos , Mama , Simulação por Computador , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Imagens de Fantasmas , Compostos Radiofarmacêuticos/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Radiol Phys Technol ; 12(3): 260-267, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31129787

RESUMO

In this study, we aimed to develop a hybrid method for automated detection of high-uptake regions in the breast and axilla using dedicated breast positron-emission tomography (db PET) and whole-body PET/computed tomography (CT) images. In our proposed method, high-uptake regions in the breast and axilla were detected using db PET images and whole-body PET/CT images. In db PET images, high-uptake regions in the breast were detected using adaptive thresholding technique based on the noise characteristics. In whole-body PET/CT images, the region of the breast that includes the axilla was first extracted using CT images. Next, high-uptake regions in the extracted breast region were detected on the PET images. By integration of the results of the two types of PET images, a final candidate region was obtained. In the experiments, the accuracy of extracting the region of the breast and detection ability was evaluated using clinical data. As a result, all breast regions were extracted correctly. The sensitivity of detection was 0.765, and the number of false positive cases were 1.8, which was 30% better than those on whole-body PET/CT alone. These results suggested that the proposed method, combining the two types of PET images is effective for improving detection performance.


Assuntos
Mama/diagnóstico por imagem , Mama/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imagem Corporal Total , Automação , Transporte Biológico , Humanos
15.
J Assoc Med Microbiol Infect Dis Can ; 4(2): 121-124, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36337744

RESUMO

We present a case of persistent Staphylococcus aureus bacteremia (SAB) with delayed diagnosis of deep-seated asymptomatic abscesses leading to an unnecessarily prolonged hospital stay and significant morbidity. This case suggests that early empiric nuclear imaging might have led to earlier source control and, in turn, reduced morbidity. In addition, the case illustrates that even with a presumed superficial source of infection, one should still search thoroughly for additional and perhaps clinically occult secondary foci in patients with high-risk SAB.


Les auteurs présentent un cas de bactériémie à Staphylococcus aureus (BSA) persistante avec diagnostic tardif d'abcès asymptomatiques profonds qui a donné lieu à une hospitalisation inutilement prolongée et à une morbidité importante. Ce cas laisse croire qu'une imagerie nucléaire empirique précoce aurait pu permettre d'en contrôler la source plus rapidement et ainsi réduire la morbidité. De plus, il démontre que, malgré la présomption d'une source d'infection superficielle, il faut tout de même faire une recherche minutieuse de foyers secondaires et peut-être occultes sur le plan clinique chez les patients à haut risque de BSA.

16.
Jpn J Radiol ; 37(1): 81-87, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30392134

RESUMO

PURPOSE: To evaluate the utility of ring-type dedicated breast positron emission tomography (dbPET) for the detection of the residual tumor after neoadjuvant chemotherapy (NAC). MATERIALS AND METHODS: This prospective study included 27 women with histologically proven breast cancer over a 37-month period. All patients underwent ring-type dbPET followed by whole-body PET-CT (WBPET) for preoperative tumor evaluation and re-staging after NAC. The maximum standardized uptake value (SUVmax) of the tumor lesion and the degree of confidence for the presence of the residual tumor were compared between pathological complete response (pCR) and non-pCR tumors. The sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) for the detection of a non-pCR tumor were compared between dbPET and WBPET. RESULTS: On dbPET, SUVmax was significantly higher in non-pCR than in pCR tumors (P = 0.030). The sensitivity for the detection of a non-pCR tumor was significantly higher with dbPET than with WBPET (84.2% vs 26.3%, P = 0.001). In the qualitative analysis, the sensitivity for the detection of a non-pCR tumor was also significantly higher with dbPET than with WBPET (57.9% vs 21.1%, P = 0.016). CONCLUSION: The dbPET can provide more sensitive detection of residual tumor after NAC than can WBPET.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Terapia Neoadjuvante/métodos , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/patologia , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasia Residual , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Resultado do Tratamento
17.
Australas Phys Eng Sci Med ; 40(4): 861-868, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29098601

RESUMO

The present study aimed to qualitatively and quantitatively evaluate PET images as a function of acquisition time for various leg sizes, and to optimize a shorter variable-acquisition time protocol for legs to achieve better qualitative and quantitative accuracy of true whole-body PET/CT images. The diameters of legs to be modeled as phantoms were defined based on data derived from 53 patients. This study analyzed PET images of a NEMA phantom and three plastic bottle phantoms (diameter, 5.68, 8.54 and 10.7 cm) that simulated the human body and legs, respectively. The phantoms comprised two spheres (diameters, 10 and 17 mm) containing fluorine-18 fluorodeoxyglucose solution with sphere-to-background ratios of 4 at a background radioactivity level of 2.65 kBq/mL. All PET data were reconstructed with acquisition times ranging from 10 to 180, and 1200 s. We visually evaluated image quality and determined the coefficient of variance (CV) of the background, contrast and the quantitative %error of the hot spheres, and then determined two shorter variable-acquisition protocols for legs. Lesion detectability and quantitative accuracy determined based on maximum standardized uptake values (SUVmax) in PET images of a patient using the proposed protocols were also evaluated. A larger phantom and a shorter acquisition time resulted in increased background noise on images and decreased the contrast in hot spheres. A visual score of ≥ 1.5 was obtained when the acquisition time was ≥ 30 s for three leg phantoms, and ≥ 120 s for the NEMA phantom. The quantitative %errors of the 10- and 17-mm spheres in the leg phantoms were ± 15 and ± 10%, respectively, in PET images with a high CV (scan < 30 s). The mean SUVmax of three lesions using the current fixed-acquisition and two proposed variable-acquisition time protocols in the clinical study were 3.1, 3.1 and 3.2, respectively, which did not significantly differ. Leg acquisition time per bed position of even 30-90 s allows axial equalization, uniform image noise and a maximum ± 15% quantitative accuracy for the smallest lesion. The overall acquisition time was reduced by 23-42% using the proposed shorter variable than the current fixed-acquisition time for imaging legs, indicating that this is a useful and practical protocol for routine qualitative and quantitative PET/CT assessment in the clinical setting.


Assuntos
Perna (Membro)/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Perna (Membro)/anatomia & histologia , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Fatores de Tempo , Adulto Jovem
18.
J Med Case Rep ; 10: 200, 2016 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-27439460

RESUMO

BACKGROUND: Limbic encephalitis was originally described as a rare clinical neuropathological entity involving seizures and neuropsychological disturbances. In this report, we describe cerebral patterns visualized by positron emission tomography in a patient with limbic encephalitis and cholangiocarcinoma. To our knowledge, there is no other description in the literature of cerebral positron emission tomography findings in the setting of limbic encephalitis and subsequent diagnosis of cholangiocarcinoma. CASE PRESENTATION: We describe a case of a 77-year-old Caucasian man who exhibited persistent cognitive changes 2 years before his death. A cerebral scan obtained at that time by 2-deoxy-2-[fluorine-18]fluoro- D -glucose integrated with computed tomography-positron emission tomography showed low radiotracer uptake in the frontal and temporal lobes. Cerebrospinal fluid analysis indicated the presence of voltage-gated potassium channel antibodies. Three months before the patient's death, a lymph node biopsy indicated a cholangiocarcinoma, and a new cerebral scan obtained by 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography-positron emission tomography showed an increment in the severity of metabolic deficit in the frontal and parietal lobes, as well as hypometabolism involving the temporal lobes. Two months before the patient's death, cerebral metastases were detected on a contrast-enhanced computed tomographic scan. Postmortem examination revealed a cholangiocarcinoma with multiple metastases including the lungs and lymph nodes. The patient's brain weighed 1300 g, and mild cortical atrophy, ex vacuo dilation of the ventricles, and mild focal thickening of the cerebellar leptomeninges, which were infiltrated by neoplastic epithelial cells, were observed. CONCLUSIONS: These findings support the need for continued vigilance in malignancy surveillance in patients with limbic encephalitis and early cerebral positron emission tomographic scan abnormalities. The difficulty in early diagnosis of small tumors, such as a cholangiocarcinoma, is discussed in the context of the clinical utility of early cerebral hypometabolism detected by 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography-positron emission tomography in patients with rapidly progressive dementia.


Assuntos
Neoplasias dos Ductos Biliares/complicações , Encefalopatias/complicações , Encefalopatias/diagnóstico por imagem , Colangiocarcinoma/complicações , Fluordesoxiglucose F18 , Encefalite Límbica/complicações , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Idoso , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Evolução Fatal , Humanos , Masculino , Compostos Radiofarmacêuticos
19.
Ann Nucl Med ; 29(9): 810-5, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26243501

RESUMO

OBJECTIVE: To evaluate the biodistribution of radiation-absorbed doses of (13)N-ammonia in healthy people. METHODS: Five healthy human subjects underwent whole-body PET and CT scans after injection of 555-740 MBq of (13)N-ammonia. Five serial dynamic emission scans in each healthy volunteer were acquired. Regions of interest were drawn on the CT image and transferred to the corresponding transverse PET slice. Estimates of the radiation-absorbed doses were calculated using the medical internal radiation dosimetry method. RESULTS: The highest concentrations of (13)N-ammonia were found in the heart and liver, followed by pancreas, brain, spleen and stomach. The highest absorbed organ doses were to the heart wall (7.14E-03 ± 3.63E-03 mGy/MBq) and kidneys (6.02E-03 ± 3.53E-03 mGy/MBq). The effective dose (ED) was 6.58E-03 ± 1.23E-03 mSv/MBq. CONCLUSIONS: With these new estimates for (13)N-ammonia dosimetry, the results for Chinese people were not appreciably different from those of the previous study performed with old devices. As one of the most important myocardial perfusion PET tracers, the whole-body (13)N-ammonia PET appears to be safe for humans, yielding a relatively modest radiation burden that would allow multiple PET studies on the same subject per year.


Assuntos
Amônia/farmacocinética , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/farmacocinética , Tomografia Computadorizada por Raios X , Imagem Corporal Total , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Radioisótopos de Nitrogênio , Tomografia por Emissão de Pósitrons/métodos , Doses de Radiação , Radiometria/métodos , Distribuição Tecidual , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos
20.
Indian J Nucl Med ; 26(2): 99-101, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22174517

RESUMO

Anti N-methyl-D-aspartate receptor encephalitis (ANMDARE), also known as limbic encephalitis (LE), is a treatable rare disorder characterized by personality changes, irritability, depression, seizures, memory loss and sometimes dementia. It is classified under paraneoplastic syndrome (PNS) and produces antibodies against NR1 and NR2 subunits of glutamate aspartate receptor. It is thought to be closely related with malignancies like small cell lung cancer, ovarian teratoma and Hodgkin's lymphoma, apart from testis, breast and rarely gastric malignancies. Non-paraneoplastic encephalitis cases are the ones with no detectable malignancy and may be triggered by severe infection. As nuclear medicine physicians, we must be aware of the diverse presentation of ANMDARE or LE and should include a whole body positron emission tomography / computed tomography (PET/CT) and not just brain PETCT during imaging. We describe the first case of PET/CT in an idiopathic ANMDARE Indian adolescent girl.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA