1.
Phys Imaging Radiat Oncol ; 31: 100637, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39297080

RESUMO

Background and purpose: In many clinics, positron-emission tomography is unavailable and clinician time extremely limited. Here we describe a deep-learning model for autocontouring gross disease for patients undergoing palliative radiotherapy for primary lung lesions and/or hilar/mediastinal nodal disease, based only on computed tomography (CT) images. Materials and methods: An autocontouring model (nnU-Net) was trained to contour gross disease in 379 cases (352 training, 27 test); 11 further test cases from an external centre were also included. Anchor-point-based post-processing was applied to remove extraneous autocontoured regions. The autocontours were evaluated quantitatively in terms of volume similarity (Dice similarity coefficient [DSC], surface Dice coefficient, 95th percentile Hausdorff distance [HD95], and mean surface distance), and scored for usability by two consultant oncologists. The magnitude of treatment margin needed to account for geometric discrepancies was also assessed. Results: The anchor point process successfully removed all erroneous regions from the autocontoured disease, and identified two cases to be excluded from further analysis due to 'missed' disease. The average DSC and HD95 were 0.8 ± 0.1 and 10.5 ± 7.3 mm, respectively. A 10-mm uniform margin-distance applied to the autocontoured region was found to yield "full coverage" (sensitivity > 0.99) of the clinical contour for 64 % of cases. Ninety-seven percent of evaluated autocontours were scored by both clinicians as requiring no or minor edits. Conclusions: Our autocontouring model was shown to produce clinically usable disease outlines, based on CT alone, for approximately two-thirds of patients undergoing lung radiotherapy. Further work is necessary to improve this before clinical implementation.

2.
Phys Eng Sci Med ; 47(3): 1123-1140, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39222214

RESUMO

Manual contouring of organs at risk (OAR) is time-consuming and subject to inter-observer variability. AI-based auto-contouring is proposed as a solution to these problems if it can produce clinically acceptable results. This study investigated the performance of multiple AI-based auto-contouring systems in different OAR segmentations. The auto-contouring was performed using seven different AI-based segmentation systems (Radiotherapy AI, Limbus AI version 1.5 and 1.6, Therapanacea, MIM, Siemens AI-Rad Companion and RadFormation) on a total of 42 clinical cases with varying anatomical sites. Volumetric and surface dice similarity coefficients and maximum Hausdorff distance (HD) between the expert's contours and automated contours were calculated to evaluate their performance. Radiotherapy AI has shown better performance than other software in most tested structures considered in the head and neck, and brain cases. No specific software had shown overall superior performance over other software in lung, breast, pelvis and abdomen cases. Each tested AI system was able to produce comparable contours to the experts' contours of organs at risk which can potentially be used for clinical use. A reduced performance of AI systems in the case of small and complex anatomical structures was found and reported, showing that it is still essential to review each contour produced by AI systems for clinical uses. This study has also demonstrated a method of comparing contouring software options which could be replicated in clinics or used for ongoing quality assurance of purchased systems.


Assuntos
Órgãos em Risco , Humanos , Inteligência Artificial , Software , Processamento de Imagem Assistida por Computador , Algoritmos , Tomografia Computadorizada por Raios X
3.
Diagnostics (Basel) ; 14(15)2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39125508

RESUMO

This study aimed to determine the relationship between geometric and dosimetric agreement metrics in head and neck (H&N) cancer radiotherapy plans. A total 287 plans were retrospectively analyzed, comparing auto-contoured and clinically used contours using a Dice similarity coefficient (DSC), surface DSC (sDSC), and Hausdorff distance (HD). Organs-at-risk (OARs) with ≥200 cGy dose differences from the clinical contour in terms of Dmax (D0.01cc) and Dmean were further examined against proximity to the planning target volume (PTV). A secondary set of 91 plans from multiple institutions validated these findings. For 4995 contour pairs across 19 OARs, 90% had a DSC, sDSC, and HD of at least 0.75, 0.86, and less than 7.65 mm, respectively. Dosimetrically, the absolute difference between the two contour sets was <200 cGy for 95% of OARs in terms of Dmax and 96% in terms of Dmean. In total, 97% of OARs exhibiting significant dose differences between the clinically edited contour and auto-contour were within 2.5 cm PTV regardless of geometric agreement. There was an approximately linear trend between geometric agreement and identifying at least 200 cGy dose differences, with higher geometric agreement corresponding to a lower fraction of cases being identified. Analysis of the secondary dataset validated these findings. Geometric indices are approximate indicators of contour quality and identify contours exhibiting significant dosimetric discordance. For a small subset of OARs within 2.5 cm of the PTV, geometric agreement metrics can be misleading in terms of contour quality.

4.
J Appl Clin Med Phys ; : e14474, 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39074490

RESUMO

BACKGROUND: The delineation of clinical target volumes (CTVs) for radiotherapy for nasopharyngeal cancer is complex and varies based on the location and extent of disease. PURPOSE: The current study aimed to develop an auto-contouring solution following one protocol guidelines (NRG-HN001) that can be adjusted to meet other guidelines, such as RTOG-0225 and the 2018 International guidelines. METHODS: The study used 2-channel 3-dimensional U-Net and nnU-Net framework to auto-contour 27 normal structures in the head and neck (H&N) region that are used to define CTVs in the protocol. To define the CTV-Expansion (CTV1 and CTV2) and CTV-Overall (the outer envelope of all the CTV contours), we used adjustable morphological geometric landmarks and mimicked physician interpretation of the protocol rules by partially or fully including select anatomic structures. The results were evaluated quantitatively using the dice similarity coefficient (DSC) and mean surface distance (MSD) and qualitatively by independent reviews by two H&N radiation oncologists. RESULTS: The auto-contouring tool showed high accuracy for nasopharyngeal CTVs. Comparison between auto-contours and clinical contours for 19 patients with cancers of various stages showed a DSC of 0.94 ± 0.02 and MSD of 0.4 ± 0.4 mm for CTV-Expansion and a DSC of 0.83 ± 0.02 and MSD of 2.4 ± 0.5 mm for CTV-Overall. Upon independent review, two H&N physicians found the auto-contours to be usable without edits in 85% and 75% of cases. In 15% of cases, minor edits were required by both physicians. Thus, one physician rated 100% of the auto-contours as usable (use as is, or after minor edits), while the other physician rated 90% as usable. The second physician required major edits in 10% of cases. CONCLUSIONS: The study demonstrates the ability of an auto-contouring tool to reliably delineate nasopharyngeal CTVs based on protocol guidelines. The tool was found to be clinically acceptable by two H&N radiation oncology physicians in at least 90% of the cases.

5.
Radiat Oncol ; 19(1): 87, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956690

RESUMO

BACKGROUND AND PURPOSE: Various deep learning auto-segmentation (DLAS) models have been proposed, some of which have been commercialized. However, the issue of performance degradation is notable when pretrained models are deployed in the clinic. This study aims to enhance precision of a popular commercial DLAS product in rectal cancer radiotherapy by localized fine-tuning, addressing challenges in practicality and generalizability in real-world clinical settings. MATERIALS AND METHODS: A total of 120 Stage II/III mid-low rectal cancer patients were retrospectively enrolled and divided into three datasets: training (n = 60), external validation (ExVal, n = 30), and generalizability evaluation (GenEva, n = 30) datasets respectively. The patients in the training and ExVal dataset were acquired on the same CT simulator, while those in GenEva were on a different CT simulator. The commercial DLAS software was first localized fine-tuned (LFT) for clinical target volume (CTV) and organs-at-risk (OAR) using the training data, and then validated on ExVal and GenEva respectively. Performance evaluation involved comparing the LFT model with the vendor-provided pretrained model (VPM) against ground truth contours, using metrics like Dice similarity coefficient (DSC), 95th Hausdorff distance (95HD), sensitivity and specificity. RESULTS: LFT significantly improved CTV delineation accuracy (p < 0.05) with LFT outperforming VPM in target volume, DSC, 95HD and specificity. Both models exhibited adequate accuracy for bladder and femoral heads, and LFT demonstrated significant enhancement in segmenting the more complex small intestine. We did not identify performance degradation when LFT and VPM models were applied in the GenEva dataset. CONCLUSIONS: The necessity and potential benefits of LFT DLAS towards institution-specific model adaption is underscored. The commercial DLAS software exhibits superior accuracy once localized fine-tuned, and is highly robust to imaging equipment changes.


Assuntos
Aprendizado Profundo , Órgãos em Risco , Planejamento da Radioterapia Assistida por Computador , Neoplasias Retais , Humanos , Neoplasias Retais/radioterapia , Neoplasias Retais/patologia , Órgãos em Risco/efeitos da radiação , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X , Adulto , Radioterapia de Intensidade Modulada/métodos
6.
BJR Open ; 6(1): tzae006, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38737623

RESUMO

Objectives: We validated an auto-contouring algorithm for heart substructures in lung cancer patients, aiming to establish its accuracy and reliability for radiotherapy (RT) planning. We focus on contouring an amalgamated set of subregions in the base of the heart considered to be a new organ at risk, the cardiac avoidance area (CAA), to enable maximum dose limit implementation in lung RT planning. Methods: The study validates a deep-learning model specifically adapted for auto-contouring the CAA (which includes the right atrium, aortic valve root, and proximal segments of the left and right coronary arteries). Geometric, dosimetric, quantitative, and qualitative validation measures are reported. Comparison with manual contours, including assessment of interobserver variability, and robustness testing over 198 cases are also conducted. Results: Geometric validation shows that auto-contouring performance lies within the expected range of manual observer variability despite being slightly poorer than the average of manual observers (mean surface distance for CAA of 1.6 vs 1.2 mm, dice similarity coefficient of 0.86 vs 0.88). Dosimetric validation demonstrates consistency between plans optimized using auto-contours and manual contours. Robustness testing confirms acceptable contours in all cases, with 80% rated as "Good" and the remaining 20% as "Useful." Conclusions: The auto-contouring algorithm for heart substructures in lung cancer patients demonstrates acceptable and comparable performance to human observers. Advances in knowledge: Accurate and reliable auto-contouring results for the CAA facilitate the implementation of a maximum dose limit to this region in lung RT planning, which has now been introduced in the routine setting at our institution.

7.
Front Oncol ; 14: 1378449, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38660134

RESUMO

Purpose: Create a comprehensive automated solution for pediatric and adult VMAT-CSI including contouring, planning, and plan check to reduce planning time and improve plan quality. Methods: Seventy-seven previously treated CSI patients (age, 2-67 years) were used for creation of an auto-contouring model to segment 25 organs at risk (OARs). The auto-contoured OARs were evaluated using the Dice Similarity Coefficient (DSC), 95% Hausdorff Distance (HD95), and a qualitative ranking by one physician and one physicist (scale: 1-acceptable, 2-minor edits, 3-major edits). The auto-planning script was developed using the Varian Eclipse Scripting API and tested with 20 patients previously treated with either low-dose VMAT-CSI (12 Gy) or high-dose VMAT-CSI (36 Gy + 18 Gy boost). Clinically relevant metrics, planning time, and blinded physician review were used to evaluate significance of differences between the auto and manual plans. Finally, the plan preparation for treatment and plan check processes were automated to improve efficiency and safety of VMAT-CSI. Results: The auto-contours achieved an average DSC of 0.71 ± 0.15, HD95 of 4.81 ± 4.68, and reviewers' ranking of 1.22 ± 0.39, indicating close to "acceptable-as-is" contours. Compared to the manual CSI plans, the auto-plans for both dose regimens achieved statistically significant reductions in body V50% and Dmean for parotids, submandibular, and thyroid glands. The variance in the dosimetric parameters decreased for the auto-plans as compared to the manual plans indicating better plan consistency. From the blinded review, the auto-plans were marked as equivalent or superior to the manual-plans 88.3% of the time. The required time for the auto-contouring and planning was consistently between 1-2 hours compared to an estimated 5-6 hours for manual contouring and planning. Conclusions: Reductions in contouring and planning time without sacrificing plan quality were obtained using the developed auto-planning process. The auto-planning scripts and documentation will be made freely available to other institutions and clinics.

8.
Phys Imaging Radiat Oncol ; 30: 100572, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38633281

RESUMO

Background and purpose: Retrospective dose evaluation for organ-at-risk auto-contours has previously used small cohorts due to additional manual effort required for treatment planning on auto-contours. We aimed to do this at large scale, by a) proposing and assessing an automated plan optimization workflow that used existing clinical plan parameters and b) using it for head-and-neck auto-contour dose evaluation. Materials and methods: Our automated workflow emulated our clinic's treatment planning protocol and reused existing clinical plan optimization parameters. This workflow recreated the original clinical plan (POG) with manual contours (PMC) and evaluated the dose effect (POG-PMC) on 70 photon and 30 proton plans of head-and-neck patients. As a use-case, the same workflow (and parameters) created a plan using auto-contours (PAC) of eight head-and-neck organs-at-risk from a commercial tool and evaluated their dose effect (PMC-PAC). Results: For plan recreation (POG-PMC), our workflow had a median impact of 1.0% and 1.5% across dose metrics of auto-contours, for photon and proton respectively. Computer time of automated planning was 25% (photon) and 42% (proton) of manual planning time. For auto-contour evaluation (PMC-PAC), we noticed an impact of 2.0% and 2.6% for photon and proton radiotherapy. All evaluations had a median ΔNTCP (Normal Tissue Complication Probability) less than 0.3%. Conclusions: The plan replication capability of our automated program provides a blueprint for other clinics to perform auto-contour dose evaluation with large patient cohorts. Finally, despite geometric differences, auto-contours had a minimal median dose impact, hence inspiring confidence in their utility and facilitating their clinical adoption.

9.
Radiat Oncol ; 19(1): 6, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38212767

RESUMO

BACKGROUND: Training senior radiation therapists as "adapters" to manage influencers and target editing is critical in daily online adaptive radiotherapy (oART) for cervical cancer. The purpose of this study was to evaluate the accuracy and dosimetric outcomes of automatic contouring and identify the key areas for modification. METHODS: A total of 125 oART fractions from five postoperative cervical cancer patients and 140 oART fractions from five uterine cervical cancer patients treated with daily iCBCT-guided oART were enrolled in this prospective study. The same adaptive treatments were replanned using the Ethos automatic contours workflow without manual contouring edits. The clinical target volume (CTV) was subdivided into several separate regions, and the average surface distance dice (ASD), centroid deviation, dice similarity coefficient (DSC), and 95% Hausdorff distance (95% HD) were used to evaluate contouring for the above portions. Dosimetric results from automatic oART plans were compared to supervised oART plans to evaluate target volumes and organs at risk (OARs) dose changes. RESULTS: Overall, the paired CTV had high overlap rates, with an average DSC value greater than 0.75. The uterus had the largest consistency differences, with ASD, centroid deviation, and 95% HD being 2.67 ± 1.79 mm, 17.17 ± 12 mm, and 10.45 ± 5.68 mm, respectively. The consistency differences of the lower nodal CTVleft and nodal CTVright were relatively large, with ASD, centroid deviation, and 95% HD being 0.59 ± 0.53 mm, 3.6 ± 2.67 mm, and 5.41 ± 4.08 mm, and 0.59 ± 0.51 mm, 3.6 ± 2.54 mm, and 4.7 ± 1.57 mm, respectively. The automatic online-adapted plan met the clinical requirements of dosimetric coverage for the target volume and improved the OAR dosimetry. CONCLUSIONS: The accuracy of automatic contouring from the Ethos adaptive platform is considered clinically acceptable for cervical cancer, and the uterus, upper vaginal cuff, and lower nodal CTV are the areas that need to be focused on in training.


Assuntos
Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Prospectivos , Dosagem Radioterapêutica , Fracionamento da Dose de Radiação , Órgãos em Risco
10.
Breast ; 73: 103599, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37992527

RESUMO

PURPOSE: To quantify interobserver variation (IOV) in target volume and organs-at-risk (OAR) contouring across 31 institutions in breast cancer cases and to explore the clinical utility of deep learning (DL)-based auto-contouring in reducing potential IOV. METHODS AND MATERIALS: In phase 1, two breast cancer cases were randomly selected and distributed to multiple institutions for contouring six clinical target volumes (CTVs) and eight OAR. In Phase 2, auto-contour sets were generated using a previously published DL Breast segmentation model and were made available for all participants. The difference in IOV of submitted contours in phases 1 and 2 was investigated quantitatively using the Dice similarity coefficient (DSC) and Hausdorff distance (HD). The qualitative analysis involved using contour heat maps to visualize the extent and location of these variations and the required modification. RESULTS: Over 800 pairwise comparisons were analysed for each structure in each case. Quantitative phase 2 metrics showed significant improvement in the mean DSC (from 0.69 to 0.77) and HD (from 34.9 to 17.9 mm). Quantitative analysis showed increased interobserver agreement in phase 2, specifically for CTV structures (5-19 %), leading to fewer manual adjustments. Underlying IOV differences causes were reported using a questionnaire and hierarchical clustering analysis based on the volume of CTVs. CONCLUSION: DL-based auto-contours improved the contour agreement for OARs and CTVs significantly, both qualitatively and quantitatively, suggesting its potential role in minimizing radiation therapy protocol deviation.


Assuntos
Neoplasias da Mama , Aprendizado Profundo , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco , Mama/diagnóstico por imagem
11.
Phys Imaging Radiat Oncol ; 28: 100501, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37920450

RESUMO

Background and purpose: Artificial Intelligence (AI)-based auto-contouring for treatment planning in radiotherapy needs extensive clinical validation, including the impact of editing after automatic segmentation. The aims of this study were to assess the performance of a commercial system for Clinical Target Volumes (CTVs) (prostate/seminal vesicles) and selected Organs at Risk (OARs) (rectum/bladder/femoral heads + femurs), evaluating also inter-observer variability (manual vs automatic + editing) and the reduction of contouring time. Materials and methods: Two expert observers contoured CTVs/OARs of 20 patients in our Treatment Planning System (TPS). Computed Tomography (CT) images were sent to the automatic contouring workstation: automatic contours were generated and sent back to TPS, where observers could edit them if necessary. Inter- and intra-observer consistency was estimated using Dice Similarity Coefficients (DSC). Radiation oncologists were also asked to score the quality of automatic contours, ranging from 1 (complete re-contouring) to 5 (no editing). Contouring times (manual vs automatic + edit) were compared. Results: DSCs (manual vs automatic only) were consistent with inter-observer variability (between 0.65 for seminal vesicles and 0.94 for bladder); editing further improved performances (range: 0.76-0.94). The median clinical score was 4 (little editing) and it was <4 in 3/2 patients for the two observers respectively. Inter-observer variability of automatic + editing contours improved significantly, being lower than manual contouring (e.g.: seminal vesicles: 0.83vs0.73; prostate: 0.86vs0.83; rectum: 0.96vs0.81). Oncologist contouring time reduced from 17 to 24 min of manual contouring time to 3-7 min of editing time for the two observers (p < 0.01). Conclusion: Automatic contouring with a commercial AI-based system followed by editing can replace manual contouring, resulting in significantly reduced time for segmentation and better consistency between operators.

12.
Med Phys ; 50(10): 5969-5977, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37646527

RESUMO

PURPOSE: Deep neural nets have revolutionized the science of auto-segmentation and present great promise for treatment planning automation. However, little data exists regarding clinical implementation and human factors. We evaluated the performance and clinical implementation of a novel deep learning-based auto-contouring workflow for 0.35T magnetic resonance imaging (MRI)-guided pelvic radiotherapy, focusing on automation bias and objective measures of workflow savings. METHODS: An auto-contouring model was developed using a UNet-derived architecture for the femoral heads, bladder, and rectum in 0.35T MR images. Training data was taken from 75 patients treated with MRI-guided radiotherapy at our institution. The model was tested against 20 retrospective cases outside the training set, and subsequently was clinically implemented. Usability was evaluated on the first 30 clinical cases by computing Dice coefficient (DSC), Hausdorff distance (HD), and the fraction of slices that were used un-modified by planners. Final contours were retrospectively reviewed by an experienced planner and clinical significance of deviations was graded as negligible, low, moderate, and high probability of leading to actionable dosimetric variations. In order to assess whether the use of auto-contouring led to final contours more or less in agreement with an objective standard, 10 pre-treatment and 10 post-treatment blinded cases were re-contoured from scratch by three expert planners to get expert consensus contours (EC). EC was compared to clinically used (CU) contours using DSC. Student's t-test and Levene's statistic were used to test statistical significance of differences in mean and standard deviation, respectively. Finally, the dosimetric significance of the contour differences were assessed by comparing the difference in bladder and rectum maximum point doses between EC and CU before and after the introduction of automation. RESULTS: Median (interquartile range) DSC for the retrospective test data were 0.92(0.02), 0.92(0.06), 0.93(0.06), 0.87(0.04) for the post-processed contours for the right and left femoral heads, bladder, and rectum, respectively. Post-implementation median DSC were 1.0(0.0), 1.0(0.0), 0.98(0.04), and 0.98(0.06), respectively. For each organ, 96.2, 95.4, 59.5, and 68.21 percent of slices were used unmodified by the planner. DSC between EC and pre-implementation CU contours were 0.91(0.05*), 0.91*(0.05*), 0.95(0.04), and 0.88(0.04) for right and left femoral heads, bladder, and rectum, respectively. The corresponding DSC for post-implementation CU contours were 0.93(0.02*), 0.93*(0.01*), 0.96(0.01), and 0.85(0.02) (asterisks indicate statistically significant difference). In a retrospective review of contours used for planning, a total of four deviating slices in two patients were graded as low potential clinical significance. No deviations were graded as moderate or high. Mean differences between EC and CU rectum max-doses were 0.1 ± 2.6 Gy and -0.9 ± 2.5 Gy for pre- and post-implementation, respectively. Mean differences between EC and CU bladder/bladder wall max-doses were -0.9 ± 4.1 Gy and 0.0 ± 0.6 Gy for pre- and post-implementation, respectively. These differences were not statistically significant according to Student's t-test. CONCLUSION: We have presented an analysis of the clinical implementation of a novel auto-contouring workflow. Substantial workflow savings were obtained. The introduction of auto-contouring into the clinical workflow changed the contouring behavior of planners. Automation bias was observed, but it had little deleterious effect on treatment planning.

13.
Front Oncol ; 13: 1119008, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37188180

RESUMO

Background and purpose: Deep learning-based models have been actively investigated for various aspects of radiotherapy. However, for cervical cancer, only a few studies dealing with the auto-segmentation of organs-at-risk (OARs) and clinical target volumes (CTVs) exist. This study aimed to train a deep learning-based auto-segmentation model for OAR/CTVs for patients with cervical cancer undergoing radiotherapy and to evaluate the model's feasibility and efficacy with not only geometric indices but also comprehensive clinical evaluation. Materials and methods: A total of 180 abdominopelvic computed tomography images were included (training set, 165; validation set, 15). Geometric indices such as the Dice similarity coefficient (DSC) and the 95% Hausdorff distance (HD) were analyzed. A Turing test was performed and physicians from other institutions were asked to delineate contours with and without using auto-segmented contours to assess inter-physician heterogeneity and contouring time. Results: The correlation between the manual and auto-segmented contours was acceptable for the anorectum, bladder, spinal cord, cauda equina, right and left femoral heads, bowel bag, uterocervix, liver, and left and right kidneys (DSC greater than 0.80). The stomach and duodenum showed DSCs of 0.67 and 0.73, respectively. CTVs showed DSCs between 0.75 and 0.80. Turing test results were favorable for most OARs and CTVs. No auto-segmented contours had large, obvious errors. The median overall satisfaction score of the participating physicians was 7 out of 10. Auto-segmentation reduced heterogeneity and shortened contouring time by 30 min among radiation oncologists from different institutions. Most participants favored the auto-contouring system. Conclusion: The proposed deep learning-based auto-segmentation model may be an efficient tool for patients with cervical cancer undergoing radiotherapy. Although the current model may not completely replace humans, it can serve as a useful and efficient tool in real-world clinics.

14.
Phys Imaging Radiat Oncol ; 26: 100426, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37063613

RESUMO

Background and purpose: Interactive segmentation seeks to incorporate human knowledge into segmentation models and thereby reducing the total amount of editing of auto-segmentations. By performing only interactions which provide new information, segmentation performance may increase cost-effectively. The aim of this study was to develop, evaluate and test feasibility of a deep learning-based single-cycle interactive segmentation model with the input being computer tomography (CT) and a small amount of information rich contours. Methods and Materials: A single-cycle interactive segmentation model, which took CT and the most cranial and caudal contour slices for each of 16 organs-at-risk for head-and-neck cancer as input, was developed. A CT-only model served as control. The models were evaluated with Dice similarity coefficient, Hausdorff Distance 95th percentile and average symmetric surface distance. A subset of 8 organs-at-risk were selected for a feasibility test. In this, a designated radiation oncologist used both single-cycle interactive segmentation and atlas-based auto-contouring for three cases. Contouring time and added path length were recorded. Results: The medians of Dice coefficients increased with single-cycle interactive segmentation in the range of 0.004 (Brain)-0.90 (EyeBack_merged) when compared to CT-only. In the feasibility test, contouring time and added path length were reduced for all three cases as compared to editing atlas-based auto-segmentations. Conclusion: Single-cycle interactive segmentation improved segmentation metrics when compared to the CT-only model and was clinically feasible from a technical and usability point of view. The study suggests that it may be cost-effective to add a small amount of contouring input to deep learning-based segmentation models.

15.
Med Phys ; 50(6): 3324-3337, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36940384

RESUMO

BACKGROUND: Absorbable hydrogel spacer injected between prostate and rectum is gaining popularity for rectal sparing. The spacer alters patient anatomy and thus requires new auto-contouring models. PURPOSE: To report the development and comprehensive evaluation of two deep-learning models for patients injected with a radio-transparent (model I) versus radiopaque (model II) spacer. METHODS AND MATERIALS: Model I was trained and cross-validated by 135 cases with transparent spacer and tested on 24 cases. Using refined training methods, model II was trained and cross-validated by the same dataset, but with the Hounsfield Unit distribution in the spacer overridden by that obtained from ten cases with opaque spacer. Model II was tested on 64 cases. The models auto-contour eight regions of interest (ROIs): spacer, prostate, proximal seminal vesicles (SVs), left and right femurs, bladder, rectum, and penile bulb. Qualitatively, each auto contour (AC), as well as the composite set, was assessed against manual contour (MC), by a radiation oncologist using a 1 (accepted directly or after minor editing), 2 (accepted after moderate editing), 3 (accepted after major editing), and 4 (rejected) scoring scale. The efficiency gain was characterized by the mean score as nearly complete [1-1.75], substantial (1.75-2.5], meaningful (2.5-3.25], and no (3.25-4.00]. Quantitatively, the geometric similarity between AC and MC was evaluated by dice similarity coefficient (DSC) and mean distance to agreement (MDA), using tolerance recommended by AAPM TG-132 Report. The results by the two models were compared to examine the outcome of the refined training methods. The large number of testing cases for model II allowed further investigation of inter-observer variability in clinical dataset. The correlation between score and DSC/MDA was studied on the ROIs with 10 or more counts of each acceptable score (1, 2, 3). RESULTS: For model I/model II: the mean score was 3.63/1.30 for transparent/opaque spacer, 2.71/2.16 for prostate, 3.25/2.44 for proximal SVs, 1.13/1.02 for both femurs, 2.25/1.25 for bladder, 3.00/2.06 for rectum, 3.38/2.42 for penile bulb, and 2.79/2.20 for the composite set; the mean DSC was 0.52/0.84 for spacer, 0.84/0.85 for prostate, 0.60/0.62 for proximal SVs, 0.94/0.96 for left femur, 0.95/0.96 for right femur, 0.91/0.95 for bladder, 0.81/0.84 for rectum, and 0.65/0.65 for penile bulb; and the mean MDA was 2.9/0.9 mm for spacer, 1.9/1.7 mm for prostate, 2.4/2.3 mm for proximal SVs, 0.8/0.5 mm for left femur, 0.7/0.5 mm for right femur, 1.5/0.9 mm for bladder, 2.3/1.9 mm for rectum, and 2.2/2.2 mm for penile bulb. Model II showed significantly improved scores for all ROIs, and metrics for spacer, femurs, bladder, and rectum. Significant inter-observer variability was only found for prostate. Highly linear correlation between the score and DSC was found for the two qualified ROIs (prostate and rectum). CONCLUSIONS: The overall efficiency gain was meaningful for model I and substantial for model II. The ROIs meeting the clinical deployment criteria (mean score below 3.25, DSC above 0.8, and MDA below 2.5 mm) included prostate, both femurs, bladder and rectum for both models, and spacer for model II.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Masculino , Humanos , Hidrogéis , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Próstata/diagnóstico por imagem , Próstata/anatomia & histologia
16.
Phys Imaging Radiat Oncol ; 24: 121-128, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36405563

RESUMO

Background and purpose: Deep learning contouring (DLC) has the potential to decrease contouring time and variability of organ contours. This work evaluates the effectiveness of DLC for prostate and head and neck across four radiotherapy centres using a commercial system. Materials and methods: Computed tomography scans of 123 prostate and 310 head and neck patients were evaluated. Besides one head and neck model, generic DLC models were used. Contouring time using centres' existing clinical methods and contour editing time after DLC were compared. Timing was evaluated using paired and non-paired studies. Commercial software or in-house scripts assessed dice similarity coefficient (DSC) and distance to agreement (DTA). One centre assessed head and neck inter-observer variability. Results: The mean contouring time saved for prostate structures using DLC compared to the existing clinical method was 5.9 ± 3.5 min. The best agreement was shown for the femoral heads (median DSC 0.92 ± 0.03, median DTA 1.5 ± 0.3 mm) and the worst for the rectum (median DSC 0.68 ± 0.04, median DTA 4.6 ± 0.6 mm). The mean contouring time saved for head and neck structures using DLC was 16.2 ± 8.6 min. For one centre there was no DLC time-saving compared to an atlas-based method. DLC contours reduced inter-observer variability compared to manual contours for the brainstem, left parotid gland and left submandibular gland. Conclusions: Generic prostate and head and neck DLC models can provide time-savings which can be assessed with paired or non-paired studies to integrate with clinical workload. Reducing inter-observer variability potential has been shown.

17.
Cancers (Basel) ; 14(22)2022 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-36428593

RESUMO

Depending on the clinical situation, different combinations of lymph node (LN) levels define the elective LN target volume in head-and-neck cancer (HNC) radiotherapy. The accurate auto-contouring of individual LN levels could reduce the burden and variability of manual segmentation and be used regardless of the primary tumor location. We evaluated three deep learning approaches for the segmenting individual LN levels I−V, which were manually contoured on CT scans from 70 HNC patients. The networks were trained and evaluated using five-fold cross-validation and ensemble learning for 60 patients with (1) 3D patch-based UNets, (2) multi-view (MV) voxel classification networks and (3) sequential UNet+MV. The performances were evaluated using Dice similarity coefficients (DSC) for automated and manual segmentations for individual levels, and the planning target volumes were extrapolated from the combined levels I−V and II−IV, both for the cross-validation and for an independent test set of 10 patients. The median DSC were 0.80, 0.66 and 0.82 for UNet, MV and UNet+MV, respectively. Overall, UNet+MV significantly (p < 0.0001) outperformed other arrangements and yielded DSC = 0.87, 0.85, 0.86, 0.82, 0.77, 0.77 for the combined and individual level I−V structures, respectively. Both PTVs were also significantly (p < 0.0001) more accurate with UNet+MV, with DSC = 0.91 and 0.90, respectively. The accurate segmentation of individual LN levels I−V can be achieved using an ensemble of UNets. UNet+MV can further refine this result.

18.
Cancers (Basel) ; 14(21)2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-36358689

RESUMO

The use of super-paramagnetic iron oxide nanoparticles (SPIONs) as an MRI contrast agent (SPION-CA) can safely label hepatic macrophages and be localized within hepatic parenchyma for T2*- and R2*-MRI of the liver. To date, no study has utilized the R2*-MRI with SPIONs for quantifying liver heterogeneity to characterize functional liver parenchyma (FLP) and hepatic tumors. This study investigates whether SPIONs enhance liver heterogeneity for an auto-contouring tool to identify the voxel-wise functional liver parenchyma volume (FLPV). This was the first study to directly evaluate the impact of SPIONs on the FLPV in R2*-MRI for 12 liver cancer patients. By using SPIONs, liver heterogeneity was improved across pre- and post-SPION MRI sessions. On average, 60% of the liver [range 40-78%] was identified as the FLPV in our auto-contouring tool with a pre-determined threshold of the mean R2* of the tumor and liver. This method performed well in 10 out of 12 liver cancer patients; the remaining 2 needed a longer echo time. These results demonstrate that our contouring tool with SPIONs can facilitate the heterogeneous R2* of the liver to automatically characterize FLP. This is a desirable technique for achieving more accurate FLPV contouring during liver radiation treatment planning.

19.
Clin Transl Radiat Oncol ; 37: 25-32, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36052018

RESUMO

Background: The prostate demonstrates inter- and intra- fractional changes and thus adaptive radiotherapy would be required to ensure optimal coverage. Daily adaptive radiotherapy for MRI-guided radiotherapy can be both time and resource intensive when structure delineation is completed manually. Contours can be auto-generated on the MR-Linac via a deformable image registration (DIR) based mapping process from the reference image. This study evaluates the performance of automatically generated target structure contours against manually delineated contours by radiation oncologists for prostate radiotherapy on the Elekta Unity MR-Linac. Methods: Plans were generated from prostate contours propagated by DIR and rigid image registration (RIR) for forty fractions from ten patients. A two-dose level SIB (simultaneous integrated boost) IMRT plan is used to treat localised prostate cancer; 6000 cGy to the prostate and 4860 cGy to the seminal vesicles. The dose coverage of the PTV 6000 and PTV 4860 created from the manually drawn target structures was evaluated with each plan. If the dose objectives were met, the plan was considered successful in covering the gold standard (clinician-delineated) volume. Results: The mandatory PTV 6000 dose objective (D98% > 5580 cGy) was met in 81 % of DIR plans and 45 % of RIR plans. The SV were mapped by DIR only and for all the plans, the PTV 4860 dose objective met the optimal target (D98% > 4617 cGy). The plans created by RIR led to under-coverage of the clinician-delineated prostate, predominantly at the apex or the bladder-prostate interface. Conclusion: Plans created from DIR propagation of prostate contours outperform those created from RIR propagation. In approximately 1 in 5 DIR plans, dosimetric coverage of the gold standard PTV was not clinically acceptable. Thus, at our institution, we use a combination of DIR propagation of contours alongside manual editing of contours where deemed necessary for online treatments.

20.
Front Oncol ; 12: 970425, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36110933

RESUMO

Purpose: To evaluate the accuracy and efficiency of Artificial-Intelligence (AI) segmentation in Total Marrow Irradiation (TMI) including contours throughout the head and neck (H&N), thorax, abdomen, and pelvis. Methods: An AI segmentation software was clinically introduced for total body contouring in TMI including 27 organs at risk (OARs) and 4 planning target volumes (PTVs). This work compares the clinically utilized contours to the AI-TMI contours for 21 patients. Structure and image dicom data was used to generate comparisons including volumetric, spatial, and dosimetric variations between the AI- and human-edited contour sets. Conventional volume and surface measures including the Sørensen-Dice coefficient (Dice) and the 95th% Hausdorff Distance (HD95) were used, and novel efficiency metrics were introduced. The clinical efficiency gains were estimated by the percentage of the AI-contour-surface within 1mm of the clinical contour surface. An unedited AI-contour has an efficiency gain=100%, an AI-contour with 70% of its surface<1mm from a clinical contour has an efficiency gain of 70%. The dosimetric deviations were estimated from the clinical dose distribution to compute the dose volume histogram (DVH) for all structures. Results: A total of 467 contours were compared in the 21 patients. In PTVs, contour surfaces deviated by >1mm in 38.6% ± 23.1% of structures, an average efficiency gain of 61.4%. Deviations >5mm were detected in 12.0% ± 21.3% of the PTV contours. In OARs, deviations >1mm were detected in 24.4% ± 27.1% of the structure surfaces and >5mm in 7.2% ± 18.0%; an average clinical efficiency gain of 75.6%. In H&N OARs, efficiency gains ranged from 42% in optic chiasm to 100% in eyes (unedited in all cases). In thorax, average efficiency gains were >80% in spinal cord, heart, and both lungs. Efficiency gains ranged from 60-70% in spleen, stomach, rectum, and bowel and 75-84% in liver, kidney, and bladder. DVH differences exceeded 0.05 in 109/467 curves at any dose level. The most common 5%-DVH variations were in esophagus (86%), rectum (48%), and PTVs (22%). Conclusions: AI auto-segmentation software offers a powerful solution for enhanced efficiency in TMI treatment planning. Whole body segmentation including PTVs and normal organs was successful based on spatial and dosimetric comparison.