Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 432
Filtrar
1.
Sensors (Basel) ; 24(13)2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-39000948

RESUMO

A dual-polarized compact Vivaldi antenna with high gain performance is proposed for tree radar applications. The proposed design introduces an array configuration consisting of two pairs of two Vivaldi elements to optimize the operating bandwidth and gain while providing dual-polarization capability. To enhance the gain of the proposed antenna over a certain frequency range of interest, directors and edge slots are incorporated into each Vivaldi element. To further enhance the overall antenna gain, a metal back reflector is used. The measurement results of the fabricated antenna show that the proposed antenna achieves a high gain of 5.5 to 14.8 dBi over broadband from 0.5 GHz to 3 GHz. Moreover, it achieves cross-polarization discrimination larger than 20 dB, ensuring high polarization purity. The fabricated antenna is used to detect and image the defects inside tree trunks. The results show that the proposed antenna yields a better-migrated image with a clear defect region compared to that obtained by a commercial Horn antenna.

2.
Nano Lett ; 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39052088

RESUMO

I-III-VI type semiconductor nanocrystals (NCs) have attracted considerable attention due to their environmental friendly nature and large-scale tunable emission. Herein, we report the successful synthesis of full-spectrum (470 to 614 nm) Ag-In-Ga-Zn-S (AIGZS) NCs by precisely regulating the In/Ga ratios using a facile one-pot method. Intriguingly, the photoluminescence (PL) peak width exhibits a continuous narrowing trend with extended reaction time, ultimately reaching a full width at half-maximum (fwhm) of 34 nm for green AIGZS NCs. Furthermore, the exciton relaxation dynamics of AIGZS NCs were systematically investigated using time-resolved photoluminescence and femtosecond transient absorption spectroscopy. Remarkably, we successfully fabricated blue, green, and red quantum-dot light-emitting diodes (QLEDs), forecasting the potential of AIGZS NCs with high color purity for applications in full-spectrum QLEDs.

3.
J Phys Condens Matter ; 36(42)2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-38981585

RESUMO

Delving into the intricate interplay between spin-orbit coupling and Coulomb correlations in strongly correlated oxides, particularly perovskite compounds, has unveiled a rich landscape of exotic phenomena ranging from unconventional superconductivity to the emergence of topological phases. In this study, we have employed pulsed laser deposition technique to grow SrIrO3(SIO) thin films on SrTiO3substrates, systematically varying the oxygen content during the post-deposition annealing. X-ray photoelectron spectroscopy (XPS) provided insights into the stoichiometry and spin-orbit splitting energy of Iridium within the SIO film, while high-resolution x-ray studies meticulously examined the structural integrity of the thin films. Remarkably, our findings indicate a decrease in the metallicity of SIO thin films with reduced annealing O2partial pressure. Furthermore, we carried out magneto-transport studies on the SIO thin films, the results revealed intriguing insights into spin transport as a function of oxygen content. The tunability of the electronic band structure of SIO films with varying oxygen vacancy is correlated with the density functional theory calculations. Our findings elucidate the intricate mechanisms dictating spin transport properties in SIO thin films, offering invaluable guidance for the design and optimization of spintronic devices based on complex oxide materials. Notably, the ability to tune bandwidth by varying post-annealing oxygen partial pressure in iridate-based spintronic materials holds significant promise for advancing technological applications in the spintronics domain.

4.
Sensors (Basel) ; 24(14)2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39066039

RESUMO

Communication systems need antennas with wide bandwidths to provide large throughput, while imaging radars benefit from high gain for increased range and wide bandwidths for high-resolution imaging. This paper presents the design and evaluation of a wideband, high-gain antenna that achieves an average gain of 9.7 dBi over a bandwidth of 1.49 GHz to 3.92 GHz by using multiple in-phase radiating apertures. The antenna has a unique structure with a central rectangular short-circuited patch sandwiched between two back-to-back U-shaped radiating patches and two flanking H-shaped short-circuited patches. Each of the U-shaped patches employs a coplanar waveguide as feeding to achieve ultra-wideband impedance matching. Benefiting from design arrangement, in-phase electrical field distributions appear at the gaps between the patches that result in equivalent radiating magnetic currents in the same direction. Theory analysis shows that the close-spaced, same-direction magnetic currents created by the radiating apertures intensify the radiation and increase antenna gain within its impedance bandwidth. Simulated data show that the use of the coplanar waveguide feeding and short-circuited patches increase the bandwidth from 65 MHz to 2.43 GHz. Moreover, the short-circuited patches increase the gain by 3.45 dB at 2.4 GHz. Simulation and measurement results validate the design and show that the antenna features a maximum gain of 11.3 dBi and an average gain of 9.7 dBi in a fractional bandwidth of 89.8%. Because of the high gain values and the wide bandwidth, the antenna is particularly suited for long-range communication systems and high-resolution radar applications.

5.
Sensors (Basel) ; 24(14)2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39066047

RESUMO

GPUs are commonly used to accelerate the execution of applications in domains such as deep learning. Deep learning applications are applied to an increasing variety of scenarios, with edge computing being one of them. However, edge devices present severe computing power and energy limitations. In this context, the use of remote GPU virtualization solutions is an efficient way to address these concerns. Nevertheless, the limited network bandwidth might be an issue. This limitation can be alleviated by leveraging on-the-fly compression within the communication layer of remote GPU virtualization solutions. In this way, data exchanged with the remote GPU is transparently compressed before being transmitted, thus increasing network bandwidth in practice. In this paper, we present the implementation of a parallel compression pipeline designed to be used within remote GPU virtualization solutions. A thorough performance analysis shows that network bandwidth can be increased by a factor of up to 2×.

6.
Micromachines (Basel) ; 15(7)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-39064321

RESUMO

The acoustically actuated nanomechanical magnetoelectric (ME) antennas represent a promising new technology that can significantly reduce antenna size by 1-2 orders of magnitude compared to traditional antennas. However, current ME antennas face challenges such as low antenna gain and narrow operating bandwidth, limiting their engineering applications. In this paper, we enhance the bandwidth and radiation performance of ME antennas through structural optimization, leveraging theoretical analysis and numerical simulations. Our findings indicate that optimizing the inner diameter of the ring-shaped ME antenna can elevate the average stress of the magnetic layer, leading to improved radiation performance and bandwidth compared to circular ME antennas. We establish an optimization model for the radiation performance of the ME antenna and conduct shape optimization simulations using COMSOL Multiphysics. The results of the Multiphysics field optimization align with the stress concentration theory, demonstrating a strong correlation between the radiation performance and bandwidth of the ME antenna with the average stress of the magnetic film. The resonant frequency in the thickness vibration mode is determined to be 170 MHz. Furthermore, shape optimization can enhance the bandwidth by up to 104% compared to circular ME antenna structures of the same size.

7.
Materials (Basel) ; 17(14)2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39063863

RESUMO

A broadband absorber based on metamaterials of graphene and vanadium dioxide (VO2) is proposed and investigated in the terahertz (THz) regime, which can be used for switch applications with a dynamically variable bandwidth by electrically and thermally controlling the Fermi energy level of graphene and the conductivity of VO2, respectively. The proposed absorber turns 'on' from 1.5 to 5.4 THz, with the modulation depth reaching 97.1% and the absorptance exceeding 90% when the Fermi energy levels of graphene are set as 0.7 eV, and VO2 is in the metallic phase. On the contrary, the absorptance is close to zero and the absorber turns 'off' with the Fermi energy level setting at 0 eV and VO2 in the insulating phase. Furthermore, other four broadband absorption modes can be achieved utilizing the active materials graphene and VO2. The proposed terahertz absorber may benefit the areas of broadband switch, cloaking objects, THz communications and other applications.

8.
Neural Netw ; 179: 106514, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-39024708

RESUMO

Shuffling-type gradient method is a popular machine learning algorithm that solves finite-sum optimization problems by randomly shuffling samples during iterations. In this paper, we explore the convergence properties of shuffling-type gradient method under mild assumptions. Specifically, we employ the bandwidth-based step size strategy that covers both monotonic and non-monotonic step sizes, thereby providing a unified convergence guarantee in terms of step size. Additionally, we replace the lower bound assumption of the objective function with that of the loss function, thereby eliminating the restrictions on the variance and the second-order moment of stochastic gradient that are difficult to verify in practice. For non-convex objectives, we recover the last iteration convergence of shuffling-type gradient algorithm with a less cumbersome proof. Meanwhile, we also establish the convergence rate for the minimum iteration of gradient norms. Under the Polyak-Lojasiewicz (PL) condition, we prove that the function value of last iteration converges to the lower bound of the objective function. By selecting appropriate boundary functions, we further improve the previous sublinear convergence rate results. Overall, this paper contributes to the understanding of shuffling-type gradient method and its convergence properties, providing insights for optimizing finite-sum problems in machine learning. Finally, numerical experiments demonstrate the efficiency of shuffling-type gradient method with bandwidth-based step size and validate our theoretical results.

9.
Sensors (Basel) ; 24(11)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38894078

RESUMO

The paper presents a wide-bandwidth, low-polarization semiconductor optical amplifier (SOA) based on strained quantum wells. By enhancing the material gain of quantum wells for TM modes, we have extended the gain bandwidth of the SOA while reducing its polarization sensitivity. Through a combination of tilted waveguide design and cavity surface optical thin film design, we have effectively reduced the cavity surface reflectance of the SOA, thus decreasing device transmission losses and noise figure. At a wavelength of 1550 nm and a drive current of 1.4 A, the output power can reach 188 mW, with a small signal gain of 36.4 dB and a 3 dB gain bandwidth of 128 nm. The linewidth broadening is only 1.032 times. The polarization-dependent gain of the SOA is below 1.4 dB, and the noise figure is below 5.5 dB. The device employs only I-line lithography technology, offering simple fabrication processes and low costs yet delivering outstanding and stable performance. The designed SOA achieves wide gain bandwidth, high gain, low polarization sensitivity, low linewidth broadening, and low noise, promising significant applications in the wide-bandwidth optical communication field across the S + C + L bands.

10.
Sensors (Basel) ; 24(12)2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38931749

RESUMO

In this paper, we investigate a scenario in which protected and unprotected services coexist in an elastic optical network under dynamic traffic. In the investigated scenario, unprotected services can reuse the reserved idle bandwidth to provide protection to the protected services. Under this scenario, we propose a new heuristic algorithm that enables such reuse as well as define and introduce a new assignment problem in elastic optical networks, named a Transmission Spectrum Assignment (T-SA) problem. In this paper, we consider a scenario in which services may be routed using the multipath routing approach. Additionally, protection using bandwidth squeezing is also considered. We assess our proposal through simulations on three different network topologies and compare our proposal against the classical protection approach, in which bandwidth reuse is not allowed. For the simulated range of network loads, the maximum (minimum) blocking probability reduction obtained by our proposal is approximately 48% (10%) in the European topology, 46% (7%) in the NSFNET topology, and 32% (6%) in the German topology.

11.
Micromachines (Basel) ; 15(6)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38930698

RESUMO

This paper presents the design of a 60 GHz millimeter-wave (MMW) slot array horn antenna based on the substrate-integrated waveguide (SIW) structure. The novelty of this device resides in the achievement of a broad impedance bandwidth and high gain performance by meticulously engineering the radiation band structure and slot array. The antenna demonstrates an impressive impedance bandwidth of 14.96 GHz (24.93%), accompanied by a remarkable maximum reflection coefficient of -39.47 dB. Furthermore, the antenna boasts a gain of 10.01 dBi, showcasing its outstanding performance as a high-frequency antenna with a wide bandwidth and high gain. To validate its capabilities, we fabricated and experimentally characterized a prototype of the antenna using a probe test structure. The measurement results closely align with the simulation results, affirming the suitability of the designed antenna for radar sensing applications in future global industrial scenarios.

12.
Nanomaterials (Basel) ; 14(11)2024 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-38869594

RESUMO

Polarization-insensitive semiconductor optical amplifiers (SOAs) in all-optical networks can improve the signal-light quality and transmission rate. Herein, to reduce the gain sensitivity to polarization, a multi-quantum-well SOA in the 1550 nm band is designed, simulated, and developed. The active region mainly comprises the quaternary compound InGaAlAs, as differences in the potential barriers and wells of the components cause lattice mismatch. Consequently, a strained quantum well is generated, providing the SOA with gain insensitivity to the polarization state of light. In simulations, the SOA with ridge widths of 4 µm, 5 µm, and 6 µm is investigated. A 3 dB gain bandwidth of >140 nm is achieved with a 4 µm ridge width, whereas a 6 µm ridge width provides more output power and gain. The saturated output power is 150 mW (21.76 dB gain) at an input power of 0 dBm but increases to 233 mW (13.67 dB gain) at an input power of 10 dBm. The polarization sensitivity is <3 dBm at -20 dBm. This design, which achieves low polarization sensitivity, a wide gain bandwidth, and high gain, will be applicable in a wide range of fields following further optimization.

13.
Electrophoresis ; 45(13-14): 1171-1181, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38837441

RESUMO

The integration of microfluidics with electric field control, commonly referred to as electrofluidics, has led to new opportunities for biomedical analysis. The requirement for closed microcapillary channels in microfluidics, typically formed via complex microlithographic fabrication approaches, limits the direct accessibility to the separation processes during conventional electrofluidic devices. Textile structures provide an alternative and low-cost approach to overcome these limitations via providing open and surface-accessible capillary channels. Herein, we investigate the potential of different 3D textile structures for electrofluidics. In this study, 12 polyester yarns were braided around nylon monofilament cores of different diameters to produce functional 3D core-shell textile structures. Capillary electrophoresis performances of these 3D core-shell textile structures both before and after removing the nylon core were evaluated in terms of mobility and bandwidth of a fluorescence marker compound. It was shown that the fibre arrangement and density govern the inherent capillary formation within these textile structures which also impacts upon the solute analyte mobility and separation bandwidth during electrophoretic studies. Core-shell textile structures with a 0.47 mm nylon core exhibited the highest fluorescein mobility and presented a narrower separation bandwidth. This optimal textile structure was readily converted to different geometries via a simple heat-setting of the central nylon core. This approach can be used to fabricate an array of miniaturized devices that possess many of the basic functionalities required in electrofluidics while maintaining open surface access that is otherwise impractical in classical approaches.


Assuntos
Eletroforese Capilar , Têxteis , Têxteis/análise , Eletroforese Capilar/métodos , Eletroforese Capilar/instrumentação , Desenho de Equipamento , Técnicas Analíticas Microfluídicas/instrumentação , Nylons/química
14.
J Psychol ; : 1-23, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38830232

RESUMO

Entrepreneurial Personality (EP) is a collection of traits that causes someone to be entrepreneurial, including both an attraction to and success in entrepreneurial activities. Although EP and its inclusion criteria is defined by its relevance to entrepreneurship, research has yet to support that it relates to entrepreneurial outcomes more strongly than extant frameworks of personality, causing uncertainty regarding its theoretical rationale and conceptual foundation. Applying the bandwidth-fidelity dilemma as our theoretical lens, the current article reports two studies to test whether EP relates to entrepreneurial outcomes beyond the HEXACO and Dark Triad dimensions. Using a sample of non-business owners, Study 1 supports that EP explains both more variance than and variance beyond the HEXACO and Dark Triad in outcomes associated with the earlier phases of the entrepreneurial process, such as entrepreneurial goal setting, goal striving, and goal achievement. Using a sample of business owners, Study 2 supports that EP explains both more variance than and variance beyond the HEXACO and Dark Triad in outcomes associated with the later phases of the entrepreneurial process, including entrepreneurial performance and well-being. These results encourage future research on EP by supporting the validity of the personality framework, and we suggest several directions for future research, such as broader applications of the bandwidth-fidelity dilemma.

15.
J Biomed Opt ; 29(Suppl 2): S22703, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38584965

RESUMO

Significance: Raman spectroscopy has been used as a powerful tool for chemical analysis, enabling the noninvasive acquisition of molecular fingerprints from various samples. Raman spectroscopy has proven to be valuable in numerous fields, including pharmaceutical, materials science, and biomedicine. Active research and development efforts are currently underway to bring this analytical instrument into the field, enabling in situ Raman measurements for a wider range of applications. Dispersive Raman spectroscopy using a fixed, narrowband source is a common method for acquiring Raman spectra. However, dispersive Raman spectroscopy requires a bulky spectrometer, which limits its field applicability. Therefore, there has been a tremendous need to develop a portable and sensitive Raman system. Aim: We developed a compact swept-source Raman (SS-Raman) spectroscopy system and proposed a signal processing method to mitigate hardware limitations. We demonstrated the capabilities of the SS-Raman spectroscopy by acquiring Raman spectra from both chemical and biological samples. These spectra were then compared with Raman spectra obtained using a conventional dispersive Raman spectroscopy system. Approach: The SS-Raman spectroscopy system used a wavelength-swept source laser (822 to 842 nm), a bandpass filter with a bandwidth of 1.5 nm, and a low-noise silicon photoreceiver. Raman spectra were acquired from various chemical samples, including phenylalanine, hydroxyapatite, glucose, and acetaminophen. A comparative analysis with the conventional dispersive Raman spectroscopy was conducted by calculating the correlation coefficients between the spectra from the SS-Raman spectroscopy and those from the conventional system. Furthermore, Raman mapping was obtained from cross-sections of swine tissue, demonstrating the applicability of the SS-Raman spectroscopy in biological samples. Results: We developed a compact SS-Raman system and validated its performance by acquiring Raman spectra from both chemical and biological materials. Our straightforward signal processing method enhanced the quality of the Raman spectra without incurring high costs. Raman spectra in the range of 900 to 1200 cm-1 were observed for phenylalanine, hydroxyapatite, glucose, and acetaminophen. The results were validated with correlation coefficients of 0.88, 0.84, 0.87, and 0.73, respectively, compared with those obtained from dispersive Raman spectroscopy. Furthermore, we performed scans across the cross-section of swine tissue to generate a biological tissue mapping plot, providing information about the composition of swine tissue. Conclusions: We demonstrate the capabilities of the proposed compact SS-Raman spectroscopy system by obtaining Raman spectra of chemical and biological materials, utilizing straightforward signal processing. We anticipate that the SS-Raman spectroscopy will be utilized in various fields, including biomedical and chemical applications.


Assuntos
Acetaminofen , Análise Espectral Raman , Suínos , Animais , Análise Espectral Raman/métodos , Glucose , Fenilalanina , Hidroxiapatitas
16.
Nanomicro Lett ; 16(1): 176, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38647737

RESUMO

The utilization of electromagnetic waves is rapidly advancing into the millimeter-wave frequency range, posing increasingly severe challenges in terms of electromagnetic pollution prevention and radar stealth. However, existing millimeter-wave absorbers are still inadequate in addressing these issues due to their monotonous magnetic resonance pattern. In this work, rare-earth La3+ and non-magnetic Zr4+ ions are simultaneously incorporated into M-type barium ferrite (BaM) to intentionally manipulate the multi-magnetic resonance behavior. By leveraging the contrary impact of La3+ and Zr4+ ions on magnetocrystalline anisotropy field, the restrictive relationship between intensity and frequency of the multi-magnetic resonance is successfully eliminated. The magnetic resonance peak-differentiating and imitating results confirm that significant multi-magnetic resonance phenomenon emerges around 35 GHz due to the reinforced exchange coupling effect between Fe3+ and Fe2+ ions. Additionally, Mössbauer spectra analysis, first-principle calculations, and least square fitting collectively identify that additional La3+ doping leads to a profound rearrangement of Zr4+ occupation and thus makes the portion of polarization/conduction loss increase gradually. As a consequence, the La3+-Zr4+ co-doped BaM achieves an ultra-broad bandwidth of 12.5 + GHz covering from 27.5 to 40 + GHz, which holds remarkable potential for millimeter-wave absorbers around the atmospheric window of 35 GHz.

17.
Sci Rep ; 14(1): 8262, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594427

RESUMO

In this paper, a wideband polarization conversion metasurface is designed. Additionally, coding and chessboard metasurfaces are specifically tailored for radar cross-section reduction (RCS). Initially, a compact unit cell demonstrating exceptional polarization conversion performance is introduced, achieving a polarization conversion ratio (PCR) exceeding 90 % across frequencies ranging from 7.9 to 22.7 GHz. The PCR remains effective even when oblique incidence angles of up to 30 ∘ are utilized across this frequency band. Roger RT5880, with a thickness of 0.254 mm, serves as the substrate. An airgap is introduced between the substrate and the ground plane to enhance the polarization conversion bandwidth. This unit cell serves as the fundamental building block for subsequent metasurface configurations. To assess the scalability and effectiveness, a 36 × 36 unit array is assembled, confirming efficient polarization conversion capabilities extending to larger structures. Moreover, a 1-bit coding unit "0" and "1" are formed by the Pancharatnam-Berry phase based on the same-sized meta-atom with 90 ∘ orientations. The robustness and practicality of the design are demonstrated by creating 12 × 12 lattices and evaluating their RCS reduction potential under two distinct scenarios: a chessboard pattern and a coding-based scheme. Notably, its results indicate substantial RCS reduction across a broad frequency spectrum (7.9 to 22.7 GHz) for both configurations. This study demonstrates the wide-ranging applicability of metasurface design, making it a valuable contribution to the fields of microwave engineering, polarization control, and radar stealth technology. Owing to its simplicity, bandwidth, and versatility, this approach offers innovative solutions for diverse real-world applications.

18.
Ann Nucl Med ; 38(6): 468-474, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38502462

RESUMO

INTRODUCTION: Heterogeneous distribution in myocardial perfusion images (MPI) obtained by scintigraphy is often observed in cardiac diseases with normal myocardial perfusion. However, quantitative assessments of such heterogeneity have not been established. We hypothesized that the heterogeneity in MPI can be quantitatively evaluated through histogram analysis, calculating the standard deviation (SD), the 95% bandwidth (BW95%), and entropy. METHODS: We examined resting 99mTc-MIBI images in 20 healthy subjects and 29 patients with cardiac disease who had none or very-mild reduced myocardial perfusion evaluated as a low summed rest score (0 to 4, the range of the studied healthy subjects). Two nuclear medicine specialists blindly divided them into two groups: non-heterogeneity or heterogeneity group, based solely on their visual assessments of heterogeneity on splash and polar maps generated from single-photon emission computed tomography (SPECT) images. The %uptake was determined by dividing the tracer count of each pixel by the tracer count of the pixel with the highest value in the LV myocardium. SD, BW95%, and entropy from histogram patterns were analyzed from the polar map data array of each %uptake. We investigated whether heterogeneity could be assessed using SD, BW95, and entropy in two groups classified by visual assessments. Additionally, we evaluated the area under the curve (AUC) to identify heterogeneity in the receiver operating characteristic curve analysis. RESULTS: Based solely on visual assessments, 11 (22%) and 38 (78%) cases were classified into the non-heterogeneity and heterogeneity groups, respectively. The non-heterogeneity group consisted of only healthy subjects, and all patients with cardiac disease were classified into the heterogeneity group. The cases in the heterogeneity group had significantly higher values of heterogeneity indices (SD, BW95%, and entropy) in %uptake than those in the non-heterogeneity group (p < 0.05 for all). The AUCs of the heterogeneity indices were sufficiently high (AUCs > 0.90 for all) in distinguishing cases with visually heterogeneous distribution or patients with cardiac disease. CONCLUSIONS: Heterogeneity in MPI can be evaluated using SD, BW95%, and entropy through histogram analysis. These novel indices may help identify patients with subtle myocardial changes, even in images that show preserved perfusion (345/350).


Assuntos
Imagem de Perfusão do Miocárdio , Tecnécio Tc 99m Sestamibi , Humanos , Imagem de Perfusão do Miocárdio/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Processamento de Imagem Assistida por Computador/métodos , Curva ROC , Cardiopatias/diagnóstico por imagem
19.
Br J Anaesth ; 132(5): 957-963, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38443287

RESUMO

BACKGROUND: Pulse oximetry uses noninvasive optical measurements of light transmission from each of two sources through vascularised living tissue over the cardiac cycle (SpO2). From those measurements, the relative amount of oxygenated haemoglobin (SaO2) in circulating blood can be deduced. Recent reports have shown that, compared with SaO2 measurements from blood samples, SpO2 measurements are biased erroneously high for patients with dark skin. METHODS: We developed a new method, spectrally resolved photoplethysmography (srPPG), to examine how spectral bandwidth affects the transmission of polychromatic light through the fingertip across the cardiac cycle. We measured and recorded the spectral transmission through the fingertip as the O2 concentration in inspired air was reduced. We applied digital spectral filters of two different bandwidths, narrow or broad, to the same srPPG recordings to determine whether SpO2 readings systematically varied for the two bandwidths. The srPPG method also allowed us to measure the fractional amount of melanin in the optical path. The effect of melanin content on the ratio of SpO2 readings for narrow and broad spectral bandwidths was analysed. RESULTS: We hypothesised, based upon the Beer-Lambert law, and then showed experimentally, that the light emission spectra of light-emitting diode light sources, as used in commercial pulse oximeters, result in erroneously high SpO2 measurements for patients having greater melanin concentrations in their skin than those of the subject pool used for instrument calibration. CONCLUSIONS: To eliminate melanin bias, pulse oximeters should use much narrower spectral bandwidths than those used in current models.


Assuntos
Melaninas , Oximetria , Humanos , Oxigênio , Oxiemoglobinas , Calibragem
20.
Micromachines (Basel) ; 15(3)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38542552

RESUMO

Ultrasonic nondestructive testing (NDT) usually utilizes conventional bulk piezoelectric transducers as transceivers. However, the complicated preparation and assembly process of bulk piezoelectric ceramics limits the development of NDT probes toward miniaturization and high frequency. In this paper, a 4.4 mm × 4.4 mm aluminum nitride (AlN) piezoelectric micromachined ultrasonic transducer (PMUT) array is designed, fabricated, characterized, and packaged for ultrasonic pulse-echo NDT of solids for the first time. The PMUT array is prepared based on the cavity silicon-on-insulator (CSOI) process and packaged using polyurethane (PU) material with acoustic properties similar to water. The fabricated PMUT array resonates at 2.183 MHz in air and at around 1.25 MHz after PU encapsulation. The bandwidth of the packaged PMUT receiver (244 kHz) is wider than that of a bulk piezoelectric transducer (179 kHz), which is good for axis resolution improvement. In this work, a hybrid ultrasonic NDT probe is designed using two packaged PMUT receivers and one 1.25 MHz bulk transmitter. The bulk transmitter radiates an ultrasonic wave into the sample, and the defect echo is received by two PMUT receivers. The 2D position of the defect could be figured out by time-of-flight (TOF) difference, and a 30 mm × 65 mm detection area is acquired. This work demonstrates the feasibility of applying AlN PMUTs to ultrasonic NDT of solids and paves the way toward a miniaturized NDT probe using AlN PMUT technology.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA