Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Sensors (Basel) ; 24(10)2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38793857

RESUMO

Bearings are crucial components of machinery and equipment, and it is essential to inspect them thoroughly to ensure a high pass rate. Currently, bearing scratch detection is primarily carried out manually, which cannot meet industrial demands. This study presents research on the detection of bearing surface scratches. An improved YOLOV5 network, named YOLOV5-CDG, is proposed for detecting bearing surface defects using scratch images as targets. The YOLOV5-CDG model is based on the YOLOV5 network model with the addition of a Coordinate Attention (CA) mechanism module, fusion of Deformable Convolutional Networks (DCNs), and a combination with the GhostNet lightweight network. To achieve bearing surface scratch detection, a machine vision-based bearing surface scratch sensor system is established, and a self-made bearing surface scratch dataset is produced as the basis. The scratch detection final Average Precision (AP) value is 97%, which is 3.4% higher than that of YOLOV5. Additionally, the model has an accuracy of 99.46% for detecting defective and qualified products. The average detection time per image is 263.4 ms on the CPU device and 12.2 ms on the GPU device, demonstrating excellent performance in terms of both speed and accuracy. Furthermore, this study analyzes and compares the detection results of various models, demonstrating that the proposed method satisfies the requirements for detecting scratches on bearing surfaces in industrial settings.

2.
J Arthroplasty ; 39(2): 514-519.e3, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37625464

RESUMO

BACKGROUND: In total hip arthroplasty (THA), femoral offset restoration results in optimal biomechanics and range of motion (ROM) without bone-bone impingement. We hypothesized that differences in implant design features significantly affect bone-bone impingement risk in primary THA. METHODS: This retrospective computer simulation study included a cohort of 43 primary robotic arm-assisted THA. Considering sagittal pelvic tilt, we measured the maximum external rotation at 0° hip flexion and the maximum internal rotation at both 90° and 100° hip flexion before any bone-bone impingement occurred. To influence the offset, we included neutral or extended polyethylene liners, neutral or plus prosthetic heads, standard or high-offset stems, and stems with 132° or 127° neck angles. RESULTS: Extended polyethylene liner use resulted in decreased bone-bone impingement for both stems but also decreased prosthetic ROM in hip extension (mean -4.5 to 5°, range -10 to 0°) and hip flexion (mean -3 to 3.7°, range -10 to 0°) due to decreases in head diameter. Using a plus head or different stem offset/neck angle options resulted in either (1) no improvement in ROM (stem 1: 60%; stem 2: 28%) or (2) a paradoxical increase in bone-bone impingement (stem 1 with 127°: 19% and stem 2 with high offset option: 7%). CONCLUSION: Counterintuitively, a subset of patients experience a paradoxical increase in bone-bone impingement when transitioning from standard to high-offset or varus necks due to the pelvic and proximal femoral bone shape. For this group of patients, preoperative personalized 3-dimensional modeling may help guide implant choice for optimizing outcomes.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Simulação por Computador , Estudos Retrospectivos , Amplitude de Movimento Articular , Polietileno
3.
Arch Orthop Trauma Surg ; 144(1): 459-464, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37615684

RESUMO

INTRODUCTION: The role of different femoral head materials for total hip arthroplasty (THA) has been widely studied in the context of wear properties and corrosion. Cobalt chrome (CoCr) femoral heads are commonly used as a standard of comparison to other materials such as ceramic and oxidized zirconium (OxZi). This study aims to evaluate the impact of femoral head material on clinical outcomes in elective primary THA patients. METHODS: Retrospective analysis of THA patients within the Medicare claims database between October 2017 and September 2020 using diagnosis-related group codes was conducted. Information collected included sex, age, Charlson Comorbidity Index, and femoral head type. Patients with CoCr femoral heads were compared against patients with either OxZi or ceramic femoral heads using 1:1 propensity score matching. Z-testing and Chi-square analysis were used to determine between-group significance. RESULTS: In total, 112,960 elective THA patients were included, with 56,480 in OxZi or ceramic and 56,480 in CoCr. Readmission rates were lower in patients that received OxZi or ceramic femoral heads at 30-day (p < 0.0001), 60-day (p < 0.0001), and 90-day postoperatively (p < 0.0001) compared to CoCr. Mortality rates were also lower in patients that received OxZi or ceramic femoral heads at 30-day (p = 0.004), 60-day (p = 0.018), and 90-day postoperatively (p = 0.009) compared to CoCr. CONCLUSION: CoCr femoral heads had higher rates of readmissions and mortality compared to OxZi or ceramic. Further analysis of bearing surface combinations and sub-group analyses to determine significance between-group differences is needed. LEVEL III EVIDENCE: Retrospective analysis.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Idoso , Estados Unidos/epidemiologia , Cabeça do Fêmur/cirurgia , Readmissão do Paciente , Estudos Retrospectivos , Fatores de Tempo , Desenho de Prótese , Medicare , Ligas de Cromo , Zircônio , Cerâmica , Falha de Prótese
4.
J Arthroplasty ; 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38040066

RESUMO

BACKGROUND: Constrained inserts in total knee arthroplasty (TKA) may offer additional stability, but can this insert type allow unrestricted movements or will the extra conformity cause kinematic conflict with the cam-post mechanism in deeper flexion? The objective of this study was to evaluate the weight-bearing kinematics of both traditional and constrained bicruciate stabilized (BCS) TKA inserts to determine if the rollback induced by the cam-post mechanism will work in unison with the constrained polyethylene insert. METHODS: This study used previously published 3-dimensional model fitting techniques to compare weight-bearing flexion and femoro-tibial condylar motion patterns for 20 patients who had a traditional insert, 20 patients who had a constrained insert, and 10 previously published nonimplanted knees, all performing a deep knee bend activity while under fluoroscopic surveillance. RESULTS: The results from this study indicate that subjects having a bicruciate stabilized TKA experienced similar postoperative kinematics for both constrained and unconstrained insert options, comparable to normal knees. CONCLUSIONS: Subjects in this study having either a constrained or traditional insert experienced progressive rollback of both condyles, with the lateral condyle rolling more posterior than the medial condyle, leading to axial rotation. Although less in magnitude, these results were comparable to the normal knee in pattern, indicating that kinematic conflict did not occur for subjects having a constrained insert.

5.
Bone Joint J ; 104-B(7): 833-843, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35775177

RESUMO

AIMS: This study reports the ten-year wear rates, incidence of osteolysis, clinical outcomes, and complications of a multicentre randomized controlled trial comparing oxidized zirconium (OxZr) versus cobalt-chrome (CoCr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) and highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA). METHODS: Patients undergoing primary THA were recruited from four institutions and prospectively allocated to the following treatment groups: Group A, CoCr femoral head with XLPE liner; Group B, OxZr femoral head with XLPE liner; and Group C, OxZr femoral head with UHMWPE liner. All study patients and assessors recording outcomes were blinded to the treatment groups. The outcomes of 262 study patients were analyzed at ten years' follow-up. RESULTS: Patients in Group C were associated with increased mean liner wear rates compared to patients in Group A (0.133 mm/yr (SD 0.21) vs 0.031 mm/yr (SD 0.07), respectively; p < 0.001) and Group B (0.133 mm/yr (SD 0.21) vs 0.022 mm/yr (SD 0.05), respectively; p < 0.001) at ten years' follow-up. Patients in Group C were also associated with increased risk of osteolysis and aseptic loosening requiring revision surgery, compared with patients in Group A (7/133 vs 0/133, respectively; p = 0.007) and Group B (7/133 vs 0/135, respectively; p = 0.007). There was a non-statistically significant trend towards increased mean liner wear rates in Group A compared with Group B (0.031 mm/yr (SD 0.07) vs 0.022 mm/yr (SD 0.05), respectively; p = 0.128). All three groups were statistically comparable preoperatively and at ten years' follow-up when measuring normalized Western Ontario and McMaster Universities Osteoarthritis Index (p = 0.410), 36-Item Short Form Health Survey (p = 0.465 mental, p = 0.713 physical), and pain scale scores (p = 0.451). CONCLUSION: The use of UHMWPE was associated with progressively increased annual liner wear rates after THA compared to XLPE. At ten years' follow-up, the group receiving UHMWPE demonstrated an increased incidence of osteolysis and aseptic loosening requiring revision surgery compared to XLPE. Femoral heads composed of OxZr were associated with trend towards reduced wear rates compared to CoCr, but this did not reach statistical significance and did not translate to any differences in osteolysis, functional outcomes, or revision surgery between the two femoral head components. Cite this article: Bone Joint J 2022;104-B(7):833-843.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Artroplastia de Quadril/efeitos adversos , Ligas de Cromo , Cobalto , Cabeça do Fêmur/cirurgia , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Osteólise/cirurgia , Polietileno , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Zircônio
6.
Nano Lett ; 22(6): 2187-2193, 2022 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-35025518

RESUMO

Scanning probe lithography (SPL) as a maskless approach with a low tool price can pattern a variety of materials at a nanometer or even atomic resolution. However, the throughput of conventional SPLs is extremely low due to their limited scanning speeds. Here, we report a high-speed, probe-based method to continuously pattern the substrate surface at a linear velocity of meters per second. We demonstrated direct writings of nanoscale patterns by using ultrafast electron-induced deposition inside a nanoscale flow at a patterning frequency of 20 MHz. The fast scan motion of the writing probe is precisely controlled by using self-adaptive hydro- and aerodynamics functions of a patterning head. The microscale electro-hydrodynamic ejection and microfluid channels are used to deliver the precursor at high scanning speeds. One patterning head can carry parallel probes to further enhance the patterning throughput. This low-cost, maskless patterning method opens new avenues to develop high-throughput nanomanufacturing techniques.


Assuntos
Nanotecnologia , Impressão , Microfluídica , Nanotecnologia/métodos
7.
Arch Orthop Trauma Surg ; 142(7): 1689-1695, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34269893

RESUMO

INTRODUCTION: The effectiveness of modern ceramic bearings has been well established in reducing the osteolysis associated with wear of the bearing surfaces in total hip arthroplasty (THA). However, there are limited mid- to long-term follow-up data for complications associated with ceramic bearings. MATERIALS AND METHODS: This case series analyzed 124 consecutive primary uncemented THAs in 108 patients with a mean age of 61 years using alumina ceramic-on-alumina ceramic bearing couples. Seventy THAs (56%) were evaluated at a minimum 14 years of follow-up; the mean follow-up period was 16 ± 1 years (14-20 years). Kaplan-Meier survivorship was determined with revision surgery for any reason as the end point. Complications were recorded focusing on osteolysis, ceramic fracture, and abnormal sounds until the final follow-up. Clinical data were scored according to the Merle d'Aubigne and Postel hip score at 14 years after THA. RESULTS: The survivorship was 93.5% (95% CI 86.7-97.0%) at 14-years postoperatively. Five patients (4.0%) underwent revision surgery due to instability or infection before 1-year postoperatively. Two patients (1.6%) underwent revision surgery due to ceramic liner fracture at 9- and 12-years postoperatively, respectively. There was no radiographic evidence of osteolysis. A total of 27 complications occurred: dislocations (n = 7/124), squeaking sounds (n = 3/124), clicking sounds (n = 6/124), ceramic liner fractures (n = 2/124), periprosthetic fractures (n = 4/124), deep infections (n = 2/124), transient sciatic nerve palsy (n = 2/124), and femoral stem breakage (n = 1/124). The Merle d'Aubigne and Postel hip score was 16.8 ± 1.4 points. CONCLUSIONS: The survivorship analysis demonstrates the uncemented THA using alumina ceramic bearings may provide favorable clinical outcome and can offer minimal wear at a minimum 14-year follow-up. Revision surgery was mostly required due to instability and infection in the short-term, and implant breakage in the mid- to long-term.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Óxido de Alumínio , Artroplastia de Quadril/efeitos adversos , Cerâmica , Seguimentos , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Pessoa de Meia-Idade , Osteólise/etiologia , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
8.
Arthroplast Today ; 10: 51-56, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34307811

RESUMO

BACKGROUND: Long-term implant durability is a key concern when considering total hip arthroplasty (THA) in young patients. The ideal bearing surface used in these patients remains unknown. The purpose of this study was to analyze trends in THA bearing surface use from 2006 to 2016 using a large, pediatric national database. METHODS: This was a retrospective review from January 1, 2006, to December 31, 2016, using the Kids' Inpatient Database. International Classification of Diseases, 9th revision and 10th revision codes were used to identify patients who underwent THA and create cohorts based on bearing surfaces: metal-on-metal, metal-on-polyethylene, ceramic-on-polyethylene (CoP), and ceramic-on-ceramic (CoC). Annual utilization of each bearing surface and associated patient and hospital demographics were analyzed. RESULTS: A total of 1004 THAs were identified during the 11-year study period. The annual number of THAs performed increased by 169% from 2006 to 2016. The mean patient age was 17.1 years. The most prevalent bearing surface used in 2006 was CoC (37.3%), metal-on-metal (31.8%) in 2009, and CoP in 2012 and 2016 (50.6% and 64.8%, respectively). From 2006 to 2016, utilization of CoP increased from 5.0% to 64.8%, representing a 1196% increase over the study period. CONCLUSIONS: The number of THAs performed in pediatric patients is increasing significantly. Although CoC was previously the most commonly used bearing surface in this patient population, CoP is currently the most common. Further investigation is needed to determine whether bearing longevity and clinical outcomes with CoP are superior to other bearing surfaces.

9.
Bone Joint J ; 103-B(7): 1231-1237, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34192941

RESUMO

AIMS: To find out if there is an inverse association between estimated glomerular filtration rate (eGFR) and whole blood cobalt (Co) and chromium (Cr) levels in patients with metal-on-metal (MoM) hip arthroplasties and renal insufficiency, suggesting that renal insufficiency could cause accumulation of Co and Cr in blood. METHODS: Out of 2,520 patients with 3,013 MoM hip arthroplasties, we identified 1,244 patients with whole blood Co, Cr, and creatinine measured within no more than a one-year interval. We analyzed the correlation of blood metal ion levels and eGFR to identify a potential trend of accumulating Co or Cr with decreasing eGFR. RESULTS: Of the 1,244 patients, 112 had normal renal function (eGFR > 90 ml/min/1.73 m2), 715 had mild renal insufficiency (eGFR 60 to 89), 384 had moderate renal insufficiency (eGFR 30 to 59), 27 had severe renal insufficiency (eGFR 15 to 29), and six had end-stage renal insufficiency (eGFR < 15). Median eGFR was 68 ml/min/1.73 m2 (interquartile range (IQR) 56 to 82), median whole blood Co was 3.3 µg/l (IQR 1.1 to 9.9), and median Cr was 2.0 µg/l (IQR 1.2 to 3.6). We did not observe an association between decreased eGFR and increased whole blood Co and Cr concentrations, but instead both increased Co and Cr were associated with higher eGFR, indicating better kidney function. CONCLUSION: As patients with MoM hip arthroplasties get older, the prevalence of renal insufficiency among them will increase, and orthopaedic surgeons will increasingly have to evaluate whether or not this affects patient follow-up. The USA Food and Drug Administration suggests that closer follow-up may be needed for MoM patients with renal insufficiency. We did not observe accumulation of blood Co or Cr in MoM hip arthroplasty patients with mild to severe renal insufficiency. Cite this article: Bone Joint J 2021;103-B(7):1231-1237.


Assuntos
Artroplastia de Quadril/instrumentação , Cromo/sangue , Cobalto/sangue , Taxa de Filtração Glomerular , Próteses Articulares Metal-Metal , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Creatinina/sangue , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
10.
J Orthop Surg Res ; 16(1): 349, 2021 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-34051798

RESUMO

BACKGROUND: To evaluate the clinical features and results of the revision total hip arthroplasties (THA) in patients with catastrophic failures and metallosis. METHODS: Fifteen hips of 14 patients with catastrophic failure and metallosis in hip arthroplasties were evaluated. They were followed for at least 4.2 years after the revision THA. Clinical evaluation was performed using Harris hip score. Osteolysis, loosening or presence of metallosis was evaluated with standard radiographs. Metallosis was evaluated intraoperatively according to the metallosis severity classification. RESULTS: The mean time from failure until revision surgery was 9.4 years. It was observed that in the primary THA, metal-on-ceramic (MoC), ceramic-on-ceramic (CoC) and metal-on-conventional polyethylene (MoCPE) bearings were used in 1, 3 and 11 hips, respectively. Grade III metallosis was observed in all patients during revision surgeries. The mean Harris hip score increased from 55 points before revision THA to 75 points at the final follow-up. In revision arthroplasty, MoCPE and CoC bearings were used in 13 and 2 hips, respectively. The femoral stem was replaced in 5 hips. All acetabular cups, except that of one hip, were revised. CONCLUSIONS: Revisions of THAs with catastrophic failures and metallosis are quite challenging. Routine follow-up of arthroplasty patients is beneficial to examine for osteolysis, loosening, and asymmetric wear.


Assuntos
Artroplastia de Quadril , Prótese de Quadril/efeitos adversos , Metais/efeitos adversos , Falha de Prótese/efeitos adversos , Reoperação/métodos , Acetábulo , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Inquéritos e Questionários , Adulto Jovem
11.
Cureus ; 13(2): e13304, 2021 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-33738155

RESUMO

Introduction An optimal hip implant is biocompatible, durable, and resistant to chemical and mechanical wear. This analysis aimed to compare failure (revision) and complication rates between ceramic-on-ceramic (CoC) and ceramic-on-highly-crosslinked-polyethylene (CoHXLPE) implants. Methods This review comprised of scientific literature published between 1995 and 2019. We included randomized controlled trials in adults (>18 years) that presented results of CoC and CoHXLPE total hip arthroplasty (THA) with more than two years of mean follow-up and drafted in English. The primary outcomes for this analysis were complications, revision rates, and loosening rates. Results Eight studies (1,689 hips) were included in this systematic review. There was no significant differences between COC and CoHXLPE for the risk of post-surgical complications (relative risk [RR]: 1.98, 95% confidence interval [CI]: 0.83-4.69, P = 0.12). Revision rates (RR: 1.25, 95% CI: 0.71-2.20, P = 0.43] and loosening rates between the two implants were not significantly different (RR: 1.17, 95% CI: 0.30-4.52, P = 0.82). Conclusion We report no significant differences between CoHXLPE and CoC in adults undergoing primary THA. Although introduced relatively recently, CoHXLPE is a cost-effective bearing that can be used for younger patients with no risk of increased complications in comparison to CoC. Further studies with longer follow-up periods are recommended to confirm the findings of this meta-analysis.

12.
J Arthroplasty ; 36(3): 991-997, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33012599

RESUMO

BACKGROUND: Prosthetic joint infection (PJI) is one of the most frequent and devastating causes of short-term revision total knee arthroplasty (TKA). In vitro evidence suggests ceramic surfaces demonstrate resistance to biofilm, but the clinical effect of bearing surface modifications on the risk of PJI remains unclear. This premier registry-based study examines the influence of ceramic bearing surface coatings on the outcome in cemented primary TKA. METHODS: In total, 117,660 cemented primary TKAs in patients with primary osteoarthritis recorded in the German arthroplasty registry since 2012 were followed up for a maximum of 3 years. The primary endpoint was risk of revision for PJI on ceramic coated and uncoated cobalt-chromium-molybdenum femoral components. Propensity score matching for age, gender, obesity, diabetes mellitus, depression and Elixhauser comorbidity index, and substratification on common design twins with and without coating was performed. RESULTS: In total, 4637 TKAs (85.1% female) with a ceramic-coated femoral component were identified, 42 had been revised for PJI and 122 for other reasons at 3 years. No survival advantage due to the risk of revision for PJI could be determined for ceramic-coated components. Revision for all other reasons demonstrated a significant higher rate for TKAs with ceramic-coated components. However, the results of this were confounded by a strong prevalence (20.7% vs 0.3%) of metal sensitivity in the ceramic-coated group. CONCLUSION: No evidence of reduced risk for PJI due to ceramic-coated implants in cemented primary TKA was found. Further analysis for revision reasons other than PJI is required.


Assuntos
Artrite Infecciosa , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Artrite Infecciosa/cirurgia , Artroplastia do Joelho/efeitos adversos , Cerâmica , Feminino , Humanos , Masculino , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação
13.
J Arthroplasty ; 36(3): 1126-1132, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33067092

RESUMO

BACKGROUND: Pitting damage on implants has been reported and attributed to the use of electrocautery. This study aimed to determine how different total knee arthroplasty bearing surfaces are susceptible to this type of damage and whether surgeons are aware that this damage can occur. METHODS: A survey was sent to Hip and Knee Society members to determine what percentage of adult reconstructive surgeons use electrocautery after implantation of components. Three bearing surfaces for total knee arthroplasty were selected: cobalt chromium, Oxinium, and zirconium nitride to be damaged by electrocautery with a monopolar (MP) and bipolar (BP) electrocautery with 3 different energy settings. A comparison of surface damage using scanning electron microscopy and elemental differences using energy dispersion spectroscopy was performed. Average roughness (Ra), maximal peak-to-valley height (Rz), kurtosis (Rk), and skewness (Rsk) were recorded for comparison using a profilometer was performed. RESULTS: Median Rz and Ra measurements were larger for BP damaged areas compared to MP for all bearing surfaces. The Oxinium surface had the greatest increase in roughness parameters. Survey results indicate that a significant percentage of adult reconstructive surgeons use the electrocautery after implants are in place and are not aware of this type of damage. Backscatter scanning electron microscopy analysis found significant changes for BP damage compared to MP. CONCLUSION: Surface damage caused by electrocautery can have significant effects on the bearing surfaces of implants but further study needs to be performed to determine if this is a clinical issue. Our survey determined that many arthroplasty experts are unaware that this damage can occur.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Adulto , Artroplastia do Joelho/efeitos adversos , Ligas de Cromo , Eletrocoagulação/efeitos adversos , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Desenho de Prótese
14.
J Orthop Traumatol ; 21(1): 15, 2020 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-32876817

RESUMO

Unicompartmental knee arthroplasty (UKA) is a bone- and ligament-sparing alternative to total knee arthroplasty in the patients with end-stage single-compartment degeneration of the knee. Despite being a successful procedure, the multiple advantages of UKA do not correlate with its usage, most likely due to the concerns regarding prosthesis survivability, patient selection, ideal bearing design, and judicious use of advanced technology among many others. Therefore, the purpose of this study is to review and summarize the debated literature and discuss the controversies as "Ten Enigmas of UKA."


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho/cirurgia , Humanos , Prótese do Joelho , Seleção de Pacientes , Falha de Prótese
15.
J Clin Orthop Trauma ; 11(Suppl 2): S196-S200, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32189939

RESUMO

BACKGROUND: The aim of this study was to compare the functional outcome, the patient's perception of the replaced hip joint with different bearing surfaces and to study the effect of femoral head size on joint perception as well. METHODS: One hundred and ten (110) patients, who underwent primary total hip replacement with an average follow-up of 48 months (12-156 months), were assessed for their functional outcome and joint perception. The functional outcome was calculated based on Oxford hip score (OHS) and SF-36. Joint perception was categorized as to whether the replaced joint was perceived like a natural joint or artificial joint with or without restriction of movements. RESULTS: There were 50 patients operated for ceramic on ceramic (CoC-hard-on-hard bearing), 60 patients for hard-on-soft bearing (Metal on Polyethelene-MoP 46, Ceramic on Polyethelene-CoP 14). Most of the patients with hard-on-hard bearings perceived their operated hip like a natural joint (p = 0.04) compared to hard-on-soft bearings. There was no significant difference in the functional outcome (OHS, SF-36) between the two bearing surface groups (p > 0.05). There were fifty patients with 28 mm size head while remaining 60 had larger heads (>32 mm). Patients with large heads felt like natural joint compared to small heads (p = 0.007). CONCLUSION: The hard-on-hard bearing surfaces (CoC) and large femoral heads (32 mm, 36 mm) are perceived more like a natural joint. Different bearing surfaces do not affect the functional outcome after total hip replacement in a medium term follow up.

16.
Hip Pelvis ; 31(4): 179-189, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31824872

RESUMO

In the 1960s, Sir John Charnley introduced to clinical practice his concept of low-friction total hip arthroplasty (THA). Although early designs were plagued by poor performance and even failure, there have been steady advances in implant designs, biomaterials, surgical techniques and an understanding of the biomechanical restoration of the hip; these advances have contributed to improvements in implant survival and clinical outcomes of THA in the past three decades. With improved wear resistance and mechanical reliability, a potential to last for at least 25 to 30 years are now available for THA. In this review, we focus on the evolution of THA and review current controversies and future directions of this procedure based on a single surgeon's 29-year of experience at a single institution.

17.
J Arthroplasty ; 34(8): 1844-1852, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31010775

RESUMO

BACKGROUND: Oxidized zirconium (OxZi) is a relatively new type of material that combines the strength of a metal with the surface/wears properties of a ceramic. Our aim was to investigate whether OxZi femoral heads lead to lower polyethylene wear, higher survival rate, and better clinical outcomes than the other bearing types in patients treated with total hip arthroplasty (THA). METHODS: Two reviewers independently conducted a systematic search according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses using the MEDLINE/PubMed database and the Cochrane Database of Systematic Reviews. These databases were queried with the terms: a. "oxidized" AND "zirconium" AND "total" AND "hip" AND "arthroplasty"; b. "oxinium" AND "total" AND "hip" AND "arthroplasty". The primary outcome measures were the survival rate of the bearing surfaces as well as the polyethylene wear. RESULTS: The vast majority (85.7%) of the studies, which reported the mean polyethylene wear rate, showed that there was not any significant difference between OxZi and cobalt-chrome (CoCr) femoral heads (rate ratio: 0.836; 95% confidence interval: 0.362-1.928; P = .674). All studies comparing the survival rate of OxZi and CoCr femoral heads illustrated almost excellent survivorship with both implants. CONCLUSION: OxZi femoral heads did not lead to lower polyethylene wear rate or higher survival rate, when compared with CoCr femoral heads in patients treated with THA. On the basis of these results and taking into account the higher cost of these implants, we would not recommend the routine use of OxZi femoral heads in primary THAs. LEVEL OF EVIDENCE: Systematic review and meta-analysis of therapeutic studies I-III.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur/cirurgia , Prótese de Quadril , Desenho de Prótese/métodos , Falha de Prótese , Zircônio/química , Cerâmica , Ligas de Cromo , Seguimentos , Humanos , Oxirredução , Polietileno , Fatores de Tempo , Resultado do Tratamento
18.
Hip Int ; 29(6): 660-664, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30630363

RESUMO

INTRODUCTION: We report 5- to 10-year clinical and radiological outcomes of a series of uncemented Oxinium on Verilast (highly cross-linked polyethylene liners) total hip replacements (THAs) using the Anthology stem and R3/Reflection cup system. METHODS: 116 THAs were performed by 2 senior authors in 104 patients from 2005 to 2009. The mean age at time of operation was 63.8 (45-80) years. The average length of follow-up was 8.8 years. At final data collection 12 patients had died (13 THAs) and 3 patients (3 THAs) were lost to follow-up. RESULTS: In the remaining 100 THAs, the preoperative Harris Hip Score of 39 improved to 91 and Oxford Hip Score improved from 16 to 44 (mean at 5 to 10 years). 100 THAs were available for radiographic analysis: all had stable bony ingrowth of both the stem and cup. Dorr's methods for wear in the 100 THAs showed an average wear <0.01 mm/year and no osteolysis; only 1 case showed 0.22 mm/year with some proximal femoral osteolysis but no cup lesions. There were no dislocations or revisions, survivorship in this series for both components for any cause as an endpoint was 100%. 1 intraoperative calcar fracture was sustained and treated with a cerclage wires, 2 peri-prosthetic fractures occurred and were treated with open reduction and fixation, both healed well with excellent outcomes. DISCUSSION: The study has shown good clinical and radiological outcomes at 5-10 years and supports existing data on the potential benefits of this bearing performance in literature.


Assuntos
Artroplastia de Quadril/métodos , Reagentes de Ligações Cruzadas , Previsões , Articulação do Quadril/cirurgia , Prótese de Quadril , Polietileno , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Radiografia
19.
Knee Surg Relat Res ; 31(1): 3, 2019 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-32660531

RESUMO

AIMS: The primary study aim was to compare early knee-specific function of patients undergoing cemented total knee arthroplasty (TKA) with either a cruciate-retaining (CR) polyethylene insert or a highly congruent condylar-stabilizing (CS) insert. Secondary aims were to compare general health and satisfaction between the groups. METHODS: A total of 418 consecutive primary TKAs were identified retrospectively. Demographics and preoperative and 1-year postoperative patient-reported outcome measures (PROMs) were collected prospectively. PROMs consisted of Oxford Knee Scores, EuroQol-5 Dimensions scores, and Short Form-12 scores. RESULTS: A total of 54 (12.9%) patients received a CS insert and 364 patients received a CR TKA. The CS group had a significantly (odds ratio (OR) 2.9; p = 0.002) greater proportion of females (77.8% versus 54.9%). The only significant difference in postoperative PROMs was a higher Short Form-12 physical component score in the CR group (difference 3.1; 95% confidence interval (CI) 0.1 to 6.1; p = 0.04). Linear regression analysis demonstrated no significant difference for all postoperative PROMs (p > 0.25). There was no significant difference in satisfaction rate (OR 0.94; 95% CI 0.42 to 2.12; p = 0.56) or pain visual analogue score (difference 6.1; 95% CI -1.9 to 14.0; p = 0.14) between the groups. CONCLUSION: More congruent CS inserts have equivalent PROMs and patient satisfaction at 1 year compared with less congruent CR inserts. These represent an option for surgeons undertaking TKA where increased congruency is desired.

20.
J Arthroplasty ; 33(9): 2716-2719, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30033065

RESUMO

Management of implant corrosion remains a challenge for the revision arthroplasty surgeon. Our field continues to gain insight in to how to manage this clinical scenario but there are still gaps in what is known to be considered to be the standard of care. There is a significant amount of effort going in to determining the best means of managing this issue but more work is needed. There is no doubt more studies are needed to further delineate the appropriate treatment algorithms for this clinical problem.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Falha de Prótese , Algoritmos , Corrosão , Feminino , Humanos , Masculino , Teste de Materiais , Salas Cirúrgicas , Desenho de Prótese , Reoperação , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA