Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
J Biomed Opt ; 29(6): 067001, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38826808

RESUMO

Significance: In the realm of cerebrovascular monitoring, primary metrics typically include blood pressure, which influences cerebral blood flow (CBF) and is contingent upon vessel radius. Measuring CBF noninvasively poses a persistent challenge, primarily attributed to the difficulty of accessing and obtaining signal from the brain. Aim: Our study aims to introduce a compact speckle contrast optical spectroscopy device for noninvasive CBF measurements at long source-to-detector distances, offering cost-effectiveness, and scalability while tracking blood flow (BF) with remarkable sensitivity and temporal resolution. Approach: The wearable sensor module consists solely of a laser diode and a board camera. It can be easily placed on a subject's head to measure BF at a sampling rate of 80 Hz. Results: Compared to the single-fiber-based version, the proposed device achieved a signal gain of about 70 times, showed superior stability, reproducibility, and signal-to-noise ratio for measuring BF at long source-to-detector distances. The device can be distributed in multiple configurations around the head. Conclusions: Given its cost-effectiveness, scalability, and simplicity, this laser-centric tool offers significant potential in advancing noninvasive cerebral monitoring technologies.


Assuntos
Circulação Cerebrovascular , Desenho de Equipamento , Análise Espectral , Humanos , Circulação Cerebrovascular/fisiologia , Análise Espectral/instrumentação , Análise Custo-Benefício , Reprodutibilidade dos Testes , Dispositivos Eletrônicos Vestíveis , Razão Sinal-Ruído , Lasers , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Imagem de Contraste de Manchas a Laser/instrumentação
2.
J Biophotonics ; 17(7): e202300491, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38664987

RESUMO

As a rapidly growing field, biophotonics demonstrates an increasingly higher demand for interdisciplinary professionals and requires the implementation of a structured approach to educational and outreach activities focused on appropriate curriculum, and teaching and learning for audiences with diverse technical backgrounds and learning styles. Our study shows the main findings upon applying this approach to biophotonics workshops delivered 2 consecutive years while updating and improving learning outcomes, teaching strategies, workshop content based on student and teacher feedback. We provided resources for a variety of lecture-based, experimental, computer simulation activities. Quality of subject matter, teaching, and overall learning was rated as "Very good" or "Good" by 88%, 76%, and 82% of students in average, respectively. Application of our teaching strategies and materials during short- and long-term workshops/courses could potentially increase the interest in pursuing careers in the biophotonics field and related areas, leading to standardized approaches in designing education and outreach events across centers.


Assuntos
Aprendizagem , Estudantes , Ensino , Humanos , Currículo , Docentes
3.
Sci Rep ; 14(1): 7984, 2024 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-38575630

RESUMO

The extent of surgical resection is an important prognostic factor in the treatment of patients with glioblastoma. Optical coherence tomography (OCT) imaging is one of the adjunctive methods available to achieve the maximal surgical resection. In this study, the tumor margins were visualized with the OCT image obtained from a murine glioma model. A commercialized human glioblastoma cell line (U-87) was employed to develop the orthotopic murine glioma model. A swept-source OCT (SS-OCT) system of 1300 nm was used for three-dimensional imaging. Based on the OCT intensity signal, which was obtained via accumulation of each A-scan data, an en-face optical attenuation coefficient (OAC) map was drawn. Due to the limited working distance of the focused beam, OAC values decrease with depth, and using the OAC difference in the superficial area was chosen to outline the tumor boundary, presenting a challenge in analyzing the tumor margin along the depth direction. To overcome this and enable three-dimensional tumor margin detection, we converted the en-face OAC map into an en-face difference map with x- and y-directions and computed the normalized absolute difference (NAD) at each depth to construct a volumetric NAD map, which was compared with the corresponding H&E-stained image. The proposed method successfully revealed the tumor margin along the peripheral boundaries as well as the margin depth. We believe this method can serve as a useful adjunct in glioma surgery, with further studies necessary for real-world practical applications.


Assuntos
Glioblastoma , Glioma , Humanos , Animais , Camundongos , Glioblastoma/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , NAD , Glioma/patologia , Imageamento Tridimensional
4.
Microvasc Res ; 154: 104671, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38460712

RESUMO

In optical imaging, optical clearing agents are commonly used to enhance the structural details of a sample. The current study investigates how to use it to improve the data obtained by an optical coherence tomography angiography system. A natural edible oil with no chemical base has been used for optical clearing. In-vivo testing on mice and humans yielded excellent optical clearing. Using computational techniques, the improvement in angiography signal caused by the optical clearing agent is investigated qualitatively and quantitatively. Compared to the control group, applying the edible oil-based optical clearing agent demonstrated improved vessel percentage and refined vascular signal intensity along depth.


Assuntos
Tomografia de Coerência Óptica , Animais , Humanos , Camundongos , Óleos de Plantas/farmacologia , Angiografia , Valor Preditivo dos Testes , Masculino
5.
Neurophotonics ; 11(1): 015008, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38464864

RESUMO

Significance: Bedside cerebral blood flow (CBF) monitoring has the potential to inform and improve care for acute neurologic diseases, but technical challenges limit the use of existing techniques in clinical practice. Aim: Here, we validate the Openwater optical system, a novel wearable headset that uses laser speckle contrast to monitor microvascular hemodynamics. Approach: We monitored 25 healthy adults with the Openwater system and concurrent transcranial Doppler (TCD) while performing a breath-hold maneuver to increase CBF. Relative blood flow (rBF) was derived from changes in speckle contrast, and relative blood volume (rBV) was derived from changes in speckle average intensity. Results: A strong correlation was observed between beat-to-beat optical rBF and TCD-measured cerebral blood flow velocity (CBFv), R=0.79; the slope of the linear fit indicates good agreement, 0.87 (95% CI: 0.83 -0.92). Beat-to-beat rBV and CBFv were also strongly correlated, R=0.72, but as expected the two variables were not proportional; changes in rBV were smaller than CBFv changes, with linear fit slope of 0.18 (95% CI: 0.17 to 0.19). Further, strong agreement was found between rBF and CBFv waveform morphology and related metrics. Conclusions: This first in vivo validation of the Openwater optical system highlights its potential as a cerebral hemodynamic monitor, but additional validation is needed in disease states.

6.
J Biomed Opt ; 29(2): 028001, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38419756

RESUMO

Significance: Radiofrequency ablation (RFA) procedures for atrial fibrillation frequently fail to prevent recurrence, partially due to limitations in assessing extent of ablation. Optical spectroscopy shows promise in assessing RFA lesion formation but has not been validated in conditions resembling those in vivo. Aim: Catheter-based near-infrared spectroscopy (NIRS) was applied to porcine hearts to demonstrate that spectrally derived optical indices remain accurate in blood and at oblique incidence angles. Approach: Porcine left atria were ablated and mapped using a custom-fabricated NIRS catheter. Each atrium was mapped first in phosphate-buffered saline (PBS) then in porcine blood. Results: NIRS measurements showed little angle dependence up to 60 deg. A trained random forest model predicted lesions with a sensitivity of 81.7%, a specificity of 86.1%, and a receiver operating characteristic curve area of 0.921. Predicted lesion maps achieved a mean structural similarity index of 0.749 and a mean normalized inner product of 0.867 when comparing maps obtained in PBS and blood. Conclusions: Catheter-based NIRS can precisely detect RFA lesions on left atria submerged in blood. Optical parameters are reliable in blood and without perpendicular contact, confirming their ability to provide useful feedback during in vivo RFA procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Animais , Suínos , Espectroscopia de Luz Próxima ao Infravermelho , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia
7.
Phys Med Biol ; 69(1)2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38048632

RESUMO

Objective.MamoRef is an mammography device that uses near-infrared light, designed to provide clinically relevant information for the screening of diseases of the breast. Using low power continuous wave lasers and a high sensitivity CCD (Charge-coupled device) that captures a diffusely reflected image of the tissue, MamoRef results in a versatile diagnostic tool that aims to fulfill a complementary role in the diagnosis of breast cancer providing information about the relative hemoglobin concentrations as well as oxygen saturation.Approach.We present the design and development of an initial prototype of MamoRef. To ensure its effectiveness, we conducted validation tests on both the theoretical basis of the reconstruction algorithm and the hardware design. Furthermore, we initiated a clinical feasibility study involving patients diagnosed with breast disease, thus evaluating the practical application and potential benefits of MamoRef in a real-world setting.Main results.Our study demonstrates the effectiveness of the reconstruction algorithm in recovering relative concentration differences among various chromophores, as confirmed by Monte Carlo simulations. These simulations show that the recovered data correlates well with the ground truth, with SSIMs of 0.8 or more. Additionally, the phantom experiments validate the hardware implementation. The initial clinical findings exhibit highly promising outcomes regarding MamoRef's ability to differentiate between lesions.Significance.MamoRef aims to be an advancement in the field of breast pathology screening and diagnostics, providing complementary information to standard diagnostic techniques. One of its main advantages is the ability of determining oxy/deoxyhemoglobin concentrations and oxygen saturation; this constitutes valuable complementary information to standard diagnostic techniques. Besides, MamoRef is a portable and relatively inexpensive device, intended to be not only used in specific medical imaging facilities. Finally, its use does not require external compression of the breast. The findings of this study underscore the potential of MamoRef in fulfilling this crucial role.


Assuntos
Doenças Mamárias , Neoplasias da Mama , Humanos , Feminino , Mamografia/métodos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/patologia , Doenças Mamárias/patologia , Imagens de Fantasmas
8.
J Biomed Opt ; 28(12): 126006, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38144697

RESUMO

Significance: Label-free, two-photon excited fluorescence (TPEF) imaging captures morphological and functional metabolic tissue changes and enables enhanced understanding of numerous diseases. However, noise and other artifacts present in these images severely complicate the extraction of biologically useful information. Aim: We aim to employ deep neural architectures in the synthesis of a multiscale denoising algorithm optimized for restoring metrics of metabolic activity from low-signal-to-noise ratio (SNR), TPEF images. Approach: TPEF images of reduced nicotinamide adenine dinucleotide (phosphate) (NAD(P)H) and flavoproteins (FAD) from freshly excised human cervical tissues are used to assess the impact of various denoising models, preprocessing methods, and data on metrics of image quality and the recovery of six metrics of metabolic function from the images relative to ground truth images. Results: Optimized recovery of the redox ratio and mitochondrial organization is achieved using a novel algorithm based on deep denoising in the wavelet transform domain. This algorithm also leads to significant improvements in peak-SNR (PSNR) and structural similarity index measure (SSIM) for all images. Interestingly, other models yield even higher PSNR and SSIM improvements, but they are not optimal for recovery of metabolic function metrics. Conclusions: Denoising algorithms can recover diagnostically useful information from low SNR label-free TPEF images and will be useful for the clinical translation of such imaging.


Assuntos
Aprendizado Profundo , Humanos , Diagnóstico por Imagem , Razão Sinal-Ruído , Análise de Ondaletas , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
9.
Front Neurosci ; 17: 1331375, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38105926

RESUMO

[This corrects the article DOI: 10.3389/fnins.2023.1086208.].

10.
J Biomed Opt ; 28(10): 102906, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37692083

RESUMO

Significance: Early tooth demineralization may be detectable through spatial analysis of polarized light images as demonstrated in this study. This may also prove useful in the early detection of epithelial tumors that comprise the majority of the cancer burden worldwide. Aim: The spatial properties of polarized light images have not been greatly exploited in biomedicine to improve sensitivity to superficial tissue regions; therefore, we investigate the optical sampling depth effects as a function of location in the backscattered polarimetric images. Approach: Backscattered linear polarization intensity distributions exhibit four-lobed patterns arising through single-scattering, multiple-scattering, and geometrical effects. These photon pathway dynamics are investigated through experimental imaging of microsphere suspensions along with corroborative computational polarization-sensitive Monte Carlo modeling. The studied sampling depth effects of linear and circular polarization images (explored in a previous study) are then evaluated on normal and demineralized human teeth, which are known to differ in their surface and sub-surface structures. Results: Backscattered linear polarization images exhibit enhanced sensitivity to near-surface properties of media (for example, surface roughness and turbidity) at specific locations within the four-lobed patterns. This yields improved differentiation of two tooth types when spatially selecting image regions in the direction perpendicular to the incident linear polarization vector. Circular polarimetric imaging also yields improved differentiation through spatial selection of regions close to the site of illumination. Improved sensitivity to superficial tissues is achieved through a combination of these linear and circular polarimetric imaging approaches. Conclusions: Heightened sampling sensitivity to tissue microstructure in the surface/near-surface region of turbid tissue-like media and dental tissue is achieved through a judicious spatial selection of specific regions in the resultant co-linear and cross-circular backscattered polarimetric images.


Assuntos
Carcinoma , Desmineralização do Dente , Humanos , Estudos de Viabilidade , Análise Espectral , Análise Espacial , Desmineralização do Dente/diagnóstico por imagem
11.
J Biomed Opt ; 28(8): 086501, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37564163

RESUMO

Significance: Organelle sizes, which are indicative of cellular status, have implications for drug development and immunology research. At the single cell level, such information could be used to study the heterogeneity of cell response to drugs or pathogens. Aim: Angularly resolved elastic light scattering is known to be sensitive to changes in organelle size distribution. We developed a Mie theory-based simulation of angular scattering from single cells to quantify the effects of noise on scattering and size estimates. Approach: We simulated randomly sampled organelle sizes (drawn from a log normal distribution), interference between different organelles' scattering, and detector noise. We quantified each noise source's effect upon the estimated mean and standard deviation of organelle size distributions. Results: The results demonstrate that signal-to-noise ratio in the angular scattering increased with the number of scatterers, cell area, and exposure time and decreased with the size distribution width. The error in estimating the mean of the size distributions remained below 5% for nearly all experimental parameters tested, but the widest size distribution tested (standard deviation of 600 nm) reached 20%. Conclusions: The simulator revealed that sparse sampling of a broad size distribution can dominate the mismatch between actual and predicted size parameters. Alternative estimation strategies could reduce the discrepancy.


Assuntos
Luz , Organelas , Simulação por Computador , Razão Sinal-Ruído , Espalhamento de Radiação
12.
J Biophotonics ; 16(10): e202200366, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37289020

RESUMO

Optical coherence tomography angiography (OCTA) in dermatology usually suffers from low image quality due to the highly scattering property of the skin, the complexity of cutaneous vasculature, and limited acquisition time. Deep-learning methods have achieved great success in many applications. However, the deep learning approach to improve dermatological OCTA images has not been investigated due to the requirement of high-performance OCTA systems and difficulty of obtaining high-quality images as ground truth. This study aims to generate proper datasets and develop a robust deep learning method to enhance the skin OCTA images. A swept-source skin OCTA system was employed to create low-quality and high-quality OCTA images with different scanning protocols. We propose a model named vascular visualization enhancement generative adversarial network and adopt an optimized data augmentation strategy and perceptual content loss function to achieve better image enhancement effect with small amount of training data. We demonstrate the superiority of the proposed method in skin OCTA image enhancement by quantitative and qualitative comparisons.


Assuntos
Aprendizado Profundo , Dermatologia , Tomografia de Coerência Óptica/métodos , Angiografia , Pele/diagnóstico por imagem
13.
Artigo em Inglês | MEDLINE | ID: mdl-37124379

RESUMO

Cherenkov images can be used for the quality assurance of dose homogeneity in total skin electron therapy (TSET). For the dose mapping purpose, this study reconstructed the patient model from 3D scans using registration algorithms and computer animation techniques. The Cherenkov light emission of the patient's surface was extracted from multi-view Cherenkov images, converted into dose distribution, and projected onto the patient's 3D model, allowing for dose cumulation and evaluation. The projected result from multiple Cherenkov cameras provides additional information about Cherenkov emission on the sides of the patients, which improves the agreement between the Cherenkov converted dose and the OSLD measurements.

14.
Front Neurosci ; 17: 1086208, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37229429

RESUMO

Functional near-infrared spectroscopy (fNIRS) promises to be a leading non-invasive neuroimaging method due to its portability and low cost. However, concerns are rising over its inclusivity of all skin tones and hair types (Parker and Ricard, 2022, Webb et al., 2022). Functional NIRS relies on direct contact of light-emitting optodes to the scalp, which can be blocked more by longer, darker, and especially curlier hair. Additionally, NIR light can be attenuated by melanin, which is accounted for in neither fNIRS hardware nor analysis methods. Recent work has shown that overlooking these considerations in other modalities like EEG leads to the disproportionate exclusion of individuals with these phenotypes-especially Black people-in both clinical and research literature (Choy, 2020; Bradford et al., 2022; Louis et al., 2023). In this article, we sought to determine if (Jöbsis, 1977) biomedical optics developers and researchers report fNIRS performance variability between skin tones and hair textures, (2a) fNIRS neuroscience practitioners report phenotypic and demographic details in their articles, and thus, (2b) is a similar pattern of participant exclusion found in EEG also present in the fNIRS literature. We present a literature review of top Biomedical Optics and Human Neuroscience journals, showing that demographic and phenotypic reporting is unpopular in both fNIRS development and neuroscience applications. We conclude with a list of recommendations to the fNIRS community including examples of Black researchers addressing these issues head-on, inclusive best practices for fNIRS researchers, and recommendations to funding and regulatory bodies to achieve an inclusive neuroscience enterprise in fNIRS and beyond.

15.
Sensors (Basel) ; 23(5)2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36904578

RESUMO

Hyperspectral microscope imaging (HMI) is an emerging modality that integrates spatial information collected by standard laboratory microscopy and the spectral-based contrast obtained by hyperspectral imaging and may be instrumental in establishing novel quantitative diagnostic methodologies, particularly in histopathology. Further expansion of HMI capabilities hinges upon the modularity and versatility of systems and their proper standardization. In this report, we describe the design, calibration, characterization, and validation of the custom-made laboratory HMI system based on a Zeiss Axiotron fully motorized microscope and a custom-developed Czerny-Turner-type monochromator. For these important steps, we rely on a previously designed calibration protocol. Validation of the system demonstrates a performance comparable to classic spectrometry laboratory systems. We further demonstrate validation against a laboratory hyperspectral imaging system for macroscopic samples, enabling future comparison of spectral imaging results across length scales. An example of the utility of our custom-made HMI system on a standard hematoxylin and eosin-stained histology slide is also shown.


Assuntos
Imageamento Hiperespectral , Microscopia , Microscopia/métodos , Análise Espectral , Calibragem , Técnicas Histológicas
16.
J Cereb Blood Flow Metab ; 43(8): 1317-1327, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36703572

RESUMO

Dynamic cerebral autoregulation (dCA) can be derived from spontaneous oscillations in arterial blood pressure (ABP) and cerebral blood flow (CBF). Transcranial Doppler (TCD) measures CBF-velocity and is commonly used to assess dCA. Diffuse correlation spectroscopy (DCS) is a promising optical technique for non-invasive CBF monitoring, so here we aimed to validate DCS as a tool for quantifying dCA. In 33 healthy adults and 17 acute ischemic stroke patients, resting-state hemodynamic were monitored simultaneously with high-speed (20 Hz) DCS and TCD. dCA parameters were calcaulated by a transfer function analysis using a Fourier decomposition of ABP and CBF (or CBF-velocity). Strong correlation was found between DCS and TCD measured gain (magnitude of regulation) in healthy volunteers (r = 0.73, p < 0.001) and stroke patients (r = 0.76, p = 0.003). DCS-gain retained strong test-retest reliability in both groups (ICC 0.87 and 0.82, respectively). DCS and TCD-derived phase (latency of regulation) did not significantly correlate in healthy volunteers (r = 0.12, p = 0.50) but moderately correlated in stroke patients (r = 0.65, p = 0.006). DCS-derived phase was reproducible in both groups (ICC 0.88 and 0.90, respectively). High-frequency DCS is a promising non-invasive bedside technique that can be leveraged to quantify dCA from resting-state data, but the discrepancy between TCD and DCS-derived phase requires further investigation.


Assuntos
AVC Isquêmico , Adulto , Humanos , Reprodutibilidade dos Testes , Velocidade do Fluxo Sanguíneo/fisiologia , Análise Espectral , Homeostase/fisiologia , Circulação Cerebrovascular/fisiologia , Ultrassonografia Doppler Transcraniana/métodos , Pressão Sanguínea/fisiologia
17.
J Pers Med ; 14(1)2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38248734

RESUMO

Personalized medicine transforms healthcare by adapting interventions to individuals' unique genetic, molecular, and clinical profiles. To maximize diagnostic and/or therapeutic efficacy, personalized medicine requires advanced imaging devices and sensors for accurate assessment and monitoring of individual patient conditions or responses to therapeutics. In the field of biomedical optics, short-wave infrared (SWIR) techniques offer an array of capabilities that hold promise to significantly enhance diagnostics, imaging, and therapeutic interventions. SWIR techniques provide in vivo information, which was previously inaccessible, by making use of its capacity to penetrate biological tissues with reduced attenuation and enable researchers and clinicians to delve deeper into anatomical structures, physiological processes, and molecular interactions. Combining SWIR techniques with machine learning (ML), which is a powerful tool for analyzing information, holds the potential to provide unprecedented accuracy for disease detection, precision in treatment guidance, and correlations of complex biological features, opening the way for the data-driven personalized medicine field. Despite numerous biomedical demonstrations that utilize cutting-edge SWIR techniques, the clinical potential of this approach has remained significantly underexplored. This paper demonstrates how the synergy between SWIR imaging and ML is reshaping biomedical research and clinical applications. As the paper showcases the growing significance of SWIR imaging techniques that are empowered by ML, it calls for continued collaboration between researchers, engineers, and clinicians to boost the translation of this technology into clinics, ultimately bridging the gap between cutting-edge technology and its potential for personalized medicine.

18.
Cancers (Basel) ; 14(22)2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36428806

RESUMO

Colorectal cancer (CRC) is the third most common and second most deadly type of cancer worldwide. Early detection not only reduces mortality but also improves patient prognosis by allowing the use of minimally invasive techniques to remove cancer while avoiding major surgery. Expanding the use of microsurgical techniques requires accurate diagnosis and delineation of the tumor margins in order to allow complete excision of cancer. We have used diffuse reflectance spectroscopy (DRS) to identify the main optical CRC biomarkers and to optimize parameters for the integration of such technologies into medical devices. A total number of 2889 diffuse reflectance spectra were collected in ex vivo specimens from 47 patients. Short source-detector distance (SDD) and long-SDD fiber-optic probes were employed to measure tissue layers from 0.5 to 1 mm and from 0.5 to 1.9 mm deep, respectively. The most important biomolecules contributing to differentiating DRS between tissue types were oxy- and deoxy-hemoglobin (Hb and HbO2), followed by water and lipid. Accurate tissue classification and potential DRS device miniaturization using Hb, HbO2, lipid and water data were achieved particularly well within the wavelength ranges 350-590 nm and 600-1230 nm for the short-SDD probe, and 380-400 nm, 420-610 nm, and 650-950 nm for the long-SDD probe.

19.
Front Physiol ; 13: 934731, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35910568

RESUMO

Cerebral blood flow (CBF) is an important physiologic parameter that is vital for proper cerebral function and recovery. Current widely accepted methods of measuring CBF are cumbersome, invasive, or have poor spatial or temporal resolution. Near infrared spectroscopy (NIRS) based measures of cerebrovascular physiology may provide a means of non-invasively, topographically, and continuously measuring CBF. We performed a systematically conducted scoping review of the available literature examining the quantitative relationship between NIRS-based cerebrovascular metrics and CBF. We found that continuous-wave NIRS (CW-NIRS) was the most examined modality with dynamic contrast enhanced NIRS (DCE-NIRS) being the next most common. Fewer studies assessed diffuse correlation spectroscopy (DCS) and frequency resolved NIRS (FR-NIRS). We did not find studies examining the relationship between time-resolved NIRS (TR-NIRS) based metrics and CBF. Studies were most frequently conducted in humans and animal studies mostly utilized large animal models. The identified studies almost exclusively used a Pearson correlation analysis. Much of the literature supported a positive linear relationship between changes in CW-NIRS based metrics, particularly regional cerebral oxygen saturation (rSO2), and changes in CBF. Linear relationships were also identified between other NIRS based modalities and CBF, however, further validation is needed.

20.
Sensors (Basel) ; 22(16)2022 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-36016033

RESUMO

Hyperspectral imaging (HSI) is a promising optical modality that is already being used in numerous applications. Further expansion of the capabilities of HSI depends on the modularity and versatility of the systems, which would, inter alia, incorporate profilometry, fluorescence imaging, and Raman spectroscopy while following a rigorous calibration and verification protocols, thus offering new insights into the studied samples as well as verifiable, quantitative measurement results applicable to the development of quantitative metrics. Considering these objectives, we developed a custom-made laboratory HSI system geared toward biomedical applications. In this report, we describe the design, along with calibration, characterization, and verification protocols needed to establish such systems, with the overall goal of standardization. As an additional novelty, our HSI system uses a custom-built broadband LED-based light source for reflectance imaging, which is particularly important for biomedical applications due to the elimination of sample heating. Three examples illustrating the utility and advantages of the integrated system in biomedical applications are shown. Our attempt presents both the development of a custom-based laboratory HSI system with novel LED light source as well as a framework which may improve technological standards in HSI system design.


Assuntos
Imageamento Hiperespectral , Imagem Óptica , Calibragem , Imagem Óptica/métodos , Análise Espectral Raman
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA