Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Occup Saf Ergon ; : 1-19, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39192658

RESUMO

Firefighters in such serious environments (i.e., hazardous flames and radiant heat, high air temperatures, hot chemicals and liquids) must wear fire protective clothing during fire extinguishing and rescue operations. Many studies in the field of fire protective clothing have been conducted to evaluate the protective, mechanical and comfort performance of fire protective clothing. A comprehensive review of the literature has been undertaken to provide a better understanding of single-layer and multilayer fire protective clothing with protective, mechanical and comfort performance. Factors affecting the durability of protective clothing in the light of their expected retirement age and a number of significant standards for laboratory and manikin testing are discussed. The comfort of wearing clothing is another aspect that needs special consideration when designing a multilayered fire protective suit. A number of emerging technologies have been outlined to address the various challenges of the present day.

2.
Materials (Basel) ; 17(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38612162

RESUMO

In this study the influence of fabric weave (plain, twill, and panama) and weft type (flax and hemp yarns) on selected mechanical and comfort properties of six fabrics was analyzed. The results showed that tear and abrasion properties were most affected by the weave. The tensile properties of the linen fabrics were not significantly different when weft hemp yarns were used instead of flax. Fabrics with the same weave seemed to be equally resilient to abrasion regardless of the type of weft. By contrast, the hemp weft yarns favorized the physical and comfort properties of the investigated fabrics. For the same weave, the hemp-linen fabrics were slightly lighter and exhibited lower bulk density, significantly larger air permeability, and improved moisture management properties. Although the results of maximum thermal flux (Qmax) suggested a cooler sensation of the linen fabrics with panama and twill, the hemp-linen fabric with a plain weave seemed to be the optimal choice when a cool sensation was desired. Higher thermal conductivity values also suggested slightly better heat transfer properties of the hemp-linen fabrics, and these were significantly influenced by the weave type. The results clearly indicated the advantages of using hemp for improving physical and specific comfort properties of linen fabrics.

3.
Materials (Basel) ; 16(23)2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38068090

RESUMO

This paper investigates the development of fabric materials using several blends of inherently fire-resistant (FR) fibers and various knitted structures. The samples are evaluated with respect to their performance and comfort-related properties. Inherently fire-resistant fibers, e.g., Nomex, Protex, carbon and FR viscose, were used to develop different structures of knitted fabrics. Cross-miss, cross-relief, and vertical tubular structures were knitted by using optimum fiber blend proportions and combinations of stitches. Several important aspects of the fabric samples were investigated, e.g., their physical, mechanical and serviceability performance. Thermo-physiological and tactile/touch-related comfort properties were evaluated in addition to flame resistance performance. An analysis of mechanical performance indicated that the knitted structure has a significant influence on the tensile strength, bursting strength and pilling resistance. The cross-relief structure proved to be the strongest followed by the cross-miss and vertical tubular structures. The FR station suits made from 70:30 Protex/Nomex exhibited the best combination of tensile and bursting strength; therefore, this material is recommended for making a stable and durable station suit. Interestingly, it was also concluded from the experimental study that knitted samples with a cross-relief structure exhibit the best fire-resistance performance. Fiber blends of 70:30 Protex/Nomex and 70:30 Nomex/carbon were found to be optimum in terms of overall performance. The best flame resistance was achieved with Nomex:carbon fiber blends. These results were confirmed with vertical flammability tests, TGA, DTGA and cone calorimetry analysis. The optimization of blend composition as well as knitting structure/architecture is a crucial finding toward designing the best FR station suit in terms of mechanical, dimensional, thermal, thermo-physiological and flame resistance performance.

4.
Materials (Basel) ; 15(17)2022 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36079542

RESUMO

Textile structures with various bioactive and functional properties are used in many areas of medicine, special clothing, interior textiles, technical goods, etc. We investigated the effect of two different textile woven structures made of 90% polyester with 10% polyamide (PET) and 100% cotton (CO) modified by magnetron sputtering with copper (Cu) on bioactive properties against Gram-positive and Gram-negative bacteria and four viruses and also on the some comfort parameters. PET/Cu and CO/Cu fabrics have strong antibacterial activity against Staphylococcus aureus and Klebsiella pneumonia. CO/Cu fabric has good antiviral activity in relation to vaccinia virus (VACV), herpes simplex virus type 1 (HSV-1) and influenza A virus H1N1 (IFV), while its antiviral activity against mouse coronavirus (MHV) is weak. PET/Cu fabric showed weak antiviral activity against HSV-1 and MHV. Both modified fabrics showed no significant toxicity in comparison to the control medium and pristine fabrics. After Cu sputtering, fabric surfaces became hydrophobic and the value of the surface free energy was over four times lower than for pristine fabrics. The modification improved thermal conductivity and thermal diffusivity, facilitated water vapour transport, and air permeability did not decrease.

5.
Polymers (Basel) ; 14(14)2022 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-35890743

RESUMO

A firefighter in the wildland fields spends an average of 8 to 16 h during which he encounters enormous physical effort and very demanding outdoor conditions of high temperatures. Research shows that the most common injuries are due to the occurrence of heat stress, and not due to lack of protection against burns. Therefore, for this very specific field of firefighting, it is necessary to provide clothing that will, in addition to adequate flame protection, provide good comfort properties such as lightweight suits, good porosity and breathability, so that gaseous sweat and heat generated by body heating can be released into the environment. The aim of this study was to determine the influence of structural parameters of multi-weft woven fabrics on two mutually contradictory properties-breathability and thermal protection. When designing fabrics, the goal was to produce a structure with a high proportion of volume pores, which, regardless of the increased volume of the fabric, insure the fabric mass would be acceptably small. Volume pores in the fabric have two roles-as a heat insulator and as an inhibitor of the breathability of the material. The analysis of the obtained results showed that the thickness and mass of the fabric have a greater influence on the water vapor resistance, while the heat transmission property is more affected by the thickness, porosity and fiber content.

6.
Polymers (Basel) ; 13(15)2021 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-34372102

RESUMO

In this study, fibrous membranes from recycled-poly(ethylene terephthalate)/silk fibroin (r-PSF) were prepared by electrospinning for filtration applications. The effect of silk fibroin on morphology, fibers diameters, pores size, wettability, chemical structure, thermo-mechanical properties, filtration efficiency, filtration performance, and comfort properties such as air and water vapor permeability was investigated. The filtration efficiency (FE) and quality factor (Qf), which represents filtration performance, were calculated from penetration through the membranes using aerosol particles ranging from 120 nm to 2.46 µm. The fiber diameter influenced both FE and Qf. However, the basis weight of the membranes has an effect, especially on the FE. The prepared membranes were classified according to EN149, and the most effective was assigned to the class FFP1 and according to EN1822 to the class H13. The impact of silk fibroin on the air permeability was assessed. Furthermore, the antibacterial activity against bacteria S. aureus and E. coli and biocompatibility were evaluated. It is discussed that antibacterial activity depends not only on the type of used materials but also on fibrous membranes' surface wettability. In vitro biocompatibility of the selected samples was studied, and it was proven to be of the non-cytotoxic effect of the keratinocytes (HaCaT) after 48 h of incubation.

7.
J Rehabil Res Dev ; 51(2): 311-24, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24933729

RESUMO

Orthotic insoles are commonly used in the treatment of the diabetic foot to prevent ulcerations. Choosing suitable insole material is vital for effective foot orthotic treatment. We examined seven types of orthotic materials. In consideration of the key requirements and end uses of orthotic insoles for the diabetic foot, including accommodation, cushioning, and control, we developed test methods for examining important physical properties, such as force reduction and compression properties, insole-skin friction, and shear properties, as well as thermal comfort properties of fabrication materials. A novel performance index that combines various material test results together was also proposed to quantify the overall performance of the insole materials. The investigation confirms that the insole-sock interface has a lower coefficient of friction and shearing stress than those of the insole-skin interface. It is also revealed that material brand and the corresponding density and cell volume, as well as thickness, are closely associated with the performance of moisture absorption and thermal comfort. On the basis of the proposed performance index, practitioners can better understand the properties and performance of various insole materials, thus prescribing suitable orthotic insoles for patients with diabetic foot.


Assuntos
Pé Diabético/reabilitação , Aparelhos Ortopédicos , Modalidades de Fisioterapia/instrumentação , Adulto , Pé Diabético/fisiopatologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Pressão , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA