1.
JACC Cardiovasc Interv ; 15(2): 150-161, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35057985

RESUMO

OBJECTIVES: The aim of this study was to determine if modifying the classical implantation technique for self-expanding (SE) transcatheter aortic valve replacement to a novel cusp-overlapping projection (COP) technique results in a higher implantation depth (ID) and subsequently reduces the rate of permanent pacemaker implantation (PPMI). BACKGROUND: The COP technique presents the potential benefit of an optimized ID to reduce the rate of PPMI. However, only a few studies have compared clinical outcomes with those achieved using the standard technique. This is the first study to systematically evaluate this approach for SE transcatheter heart valves (THVs) in different populations METHODS: Beginning in February 2015, 444 patients were consecutively included. Propensity score matching was used to control baseline characteristics because of the observational nature of the study. In total, 161 pairs of patients were analyzed. Three methods were used to measure ID (noncoronary cusp [NCC] to the THV, mean of the NCC and the left coronary cusp [LCC] to the THV, and the deepest edge from the LCC and the NCC to the THV). RESULTS: ID was significantly higher in COP cases when measuring from the NCC (4.2 mm vs 5.3 mm; P < 0.001) and the mean from the NCC and the LCC (5.3 mm vs 5.9 mm; P = 0.04), but not from the deepest edge. The PPMI rate was lower in the COP group: 19 (11.8%) vs 35 (21.7%) (P = 0.03; relative risk: 0.54; 95% CI: 0.32-0.91). CONCLUSIONS: The present study showed that the COP technique significantly reduces PPMI in SE THV implantation compared with the classical implantation technique, with similar rates of complications.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Pontuação de Propensão , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Rev Esp Cardiol (Engl Ed) ; 75(5): 412-420, 2022 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-34226165

RESUMO

INTRODUCTION AND OBJECTIVES: This study aimed to determine the safety and efficacy of modifying the classic implantation technique for aortic transcatheter heart valve (THV) implantation to a cusp-overlap-projection (COP) technique to achieve a higher implantation depth and to reduce the burden of new permanent pacemaker implantation (PPMI) at 30 days. Aortic self-expanding THV carries an elevated risk for PPMI. A higher implantation depth minimizes the damage in the conduction system and may reduce PPMI rates. METHODS: From March 2017, 226 patients were consecutively included: 113 patients were treated using the COP implantation technique compared with the previous 113 consecutive patients treated using the classic technique. In all patients, implantation depth was assessed by 3 methods (noncoronary cusp to the THV, mean of the noncoronary cusp and the left coronary cusp to the THV, and the deepest edge from the left coronary cusp and the noncoronary cusp to the THV). RESULTS: The COP group had a lower implantation depth than the group treated with the classic technique (4.8 mm± 2.2 vs 5.7 mm± 3.1; P=.011; 5.8 mm± 3.1 vs 6.5 mm± 2.4; P=.095; 7.1 mm± 2.8 vs 7.4 mm±3.2; P=.392). Forty patients (17.7%) required a new PPMI after the 30-day follow-up but this requirement was significantly lower in the COP group (12.4% vs 23%, P=.036). The COP implantation technique consistently protected against the main event (OR, 0.45; 95%CI, 0.21-0.97; P=.043), with similar procedural success rates and complications. CONCLUSIONS: The COP implantation technique is a simple modification of the implantation protocol and provides a higher implantation depth of self-expanding-THV with lower conduction disturbances and PPMI rates.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento