Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 143
Filtrar
1.
ArXiv ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38979484

RESUMO

Diffusion magnetic resonance imaging (dMRI) is pivotal for probing the microstructure of the rapidly-developing fetal brain. However, fetal motion during scans and its interaction with magnetic field inhomogeneities result in artifacts and data scattering across spatial and angular domains. The effects of those artifacts are more pronounced in high-angular resolution fetal dMRI, where signal-to-noise ratio is very low. Those effects lead to biased estimates and compromise the consistency and reliability of dMRI analysis. This work presents HAITCH, the first and the only publicly available tool to correct and reconstruct multi-shell high-angular resolution fetal dMRI data. HAITCH offers several technical advances that include a blip-reversed dual-echo acquisition for dynamic distortion correction, advanced motion correction for model-free and robust reconstruction, optimized multi-shell design for enhanced information capture and increased tolerance to motion, and outlier detection for improved reconstruction fidelity. The framework is open-source, flexible, and can be used to process any type of fetal dMRI data including single-echo or single-shell acquisitions, but is most effective when used with multi-shell multi-echo fetal dMRI data that cannot be processed with any of the existing tools. Validation experiments on real fetal dMRI scans demonstrate significant improvements and accurate correction across diverse fetal ages and motion levels. HAITCH successfully removes artifacts and reconstructs high-fidelity fetal dMRI data suitable for advanced diffusion modeling, including fiber orientation distribution function estimation. These advancements pave the way for more reliable analysis of the fetal brain microstructure and tractography under challenging imaging conditions.

2.
J Imaging Inform Med ; 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39080159

RESUMO

Geometric distortions in brain MRI images arising from susceptibility artifacts at air-tissue interfaces pose a significant challenge for high-precision radiation therapy modalities like stereotactic radiosurgery, necessitating sub-millimeter accuracy. To achieve this goal, we developed AutoCorNN, an unsupervised physics-aware deep-learning model for correcting geometric distortions. Two publicly available datasets, the MPI-Leipzig Mind-Brain-Body with 318 subjects, and the Vestibular Schwannoma-SEG dataset, encompassing 242 patients were utilized. AutoCorNN integrates two 2D convolutional encoder-decoder neural networks with the forward physical model of MRI signal generation to predict undistorted MR and field map images from distorted MR input. The network is trained in an unsupervised manner by minimizing the mean absolute error between the measured and estimated k-space data, without requiring ground truth images during training or deployment. The model was evaluated on vestibular schwannoma cases. AutoCorNN achieved a peak signal-to-noise ratio (PSNR) of 41.35 ± 0.02 dB, a root mean square error (RMSE) of 0.02 ± 0.003, and a structural similarity index (SSIM) of 0.99 ± 0.02 outperforming uncorrected and B0-mapping correction methods. Geometric distortions of about 1.6 mm were observed at the air-tissue interfaces at the air canal and nasal cavity borders. Geometrically, distortion correction increased the target volume from 3.12 ± 0.52 cc to 3.84 ± 0.54 cc. Dosimetrically, AutoCorNN improved target coverage (0.96 ± 0.01 to 0.97 ± 0.02), conformity index (0.92 ± 0.03 to 0.94 ± 0.03), and reduced dose gradients outside the target. AutoCorNN achieves accurate geometric distortion correction comparable to conventional iterative methods while offering substantial computational acceleration, enabling precise target delineation and conformal dose delivery for improved radiation therapy outcomes.

3.
J Imaging ; 10(6)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38921621

RESUMO

Thanks to the line-scanning camera, the measurement method based on line-scanning stereo vision has high optical accuracy, data transmission efficiency, and a wide field of vision. It is more suitable for continuous operation and high-speed transmission of industrial product detection sites. However, the one-dimensional imaging characteristics of the line-scanning camera cause motion distortion during image data acquisition, which directly affects the accuracy of detection. Effectively reducing the influence of motion distortion is the primary problem to ensure detection accuracy. To obtain the two-dimensional color image and three-dimensional contour data of the heavy rail surface at the same time, a binocular color line-scanning stereo vision system is designed to collect the heavy rail surface data combined with the bright field illumination of the symmetrical linear light source. Aiming at the image motion distortion caused by system installation error and collaborative acquisition frame rate mismatch, this paper uses the checkerboard target and two-step cubature Kalman filter algorithm to solve the nonlinear parameters in the motion distortion model, estimate the real motion, and correct the image information. The experiments show that the accuracy of the data contained in the image is improved by 57.3% after correction.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38834903

RESUMO

PURPOSE: This work presents a novel platform for stereo reconstruction in anterior segment ophthalmic surgery to enable enhanced scene understanding, especially depth perception, for advanced computer-assisted eye surgery by effectively addressing the lack of texture and corneal distortions artifacts in the surgical scene. METHODS: The proposed platform for stereo reconstruction uses a two-step approach: generating a sparse 3D point cloud from microscopic images, deriving a dense 3D representation by fitting surfaces onto the point cloud, and considering geometrical priors of the eye anatomy. We incorporate a pre-processing step to rectify distortion artifacts induced by the cornea's high refractive power, achieved by aligning a 3D phenotypical cornea geometry model to the images and computing a distortion map using ray tracing. RESULTS: The accuracy of 3D reconstruction is evaluated on stereo microscopic images of ex vivo porcine eyes, rigid phantom eyes, and synthetic photo-realistic images. The results demonstrate the potential of the proposed platform to enhance scene understanding via an accurate 3D representation of the eye and enable the estimation of instrument to layer distances in porcine eyes with a mean average error of 190  µ m , comparable to the scale of surgeons' hand tremor. CONCLUSION: This work marks a significant advancement in stereo reconstruction for ophthalmic surgery by addressing corneal distortions, a previously often overlooked aspect in such surgical scenarios. This could improve surgical outcomes by allowing for intra-operative computer assistance, e.g., in the form of virtual distance sensors.

5.
Nano Lett ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38856109

RESUMO

Irreversible ultrafast events are prevalent in nature, yet their capture in real time poses significant challenges. Traditional single-shot imaging technologies, which utilize a single optical pump and single delayed electron probe, offer high spatiotemporal resolution but fail to capture the entire dynamic evolutions. Here, we introduce a novel imaging method employing a single optical pump and delayed multiple electron probes. This approach, facilitated by an innovative deflector in ultrafast electron microscopy, enables the acquisition of nine frames per exposure, paving the way for statistical and quantitative analyses. We have developed an algorithm that corrects frame-by-frame distortions, realizing a cross-correlation enhancement of ∼26%. Achieving ∼12 nm and 20 ns resolution, our method allows for the comprehensive visualization of laser-induced behaviors in Au nanoparticles, including merging, jumping, and collision processes. Our results demonstrate the capability of this multiframe imaging technique to document irreversible processes across materials science and biology with unprecedented nanometer-nanosecond precision.

6.
Magn Reson Med ; 92(3): 1011-1021, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38623991

RESUMO

PURPOSE: Demonstrate the potential of spatiotemporal encoding (SPEN) MRI to deliver largely undistorted 2D, 3D, and diffusion weighted images on a 110 mT portable system. METHODS: SPEN's quadratic phase modulation was used to subsample the low-bandwidth dimension of echo planar acquisitions, delivering alias-free images with an enhanced immunity to image distortions in a laboratory-built, low-field, portable MRI system lacking multiple receivers. RESULTS: Healthy brain images with different SPEN time-bandwidth products and subsampling factors were collected. These compared favorably to EPI acquisitions including topup corrections. Robust 3D and diffusion weighted SPEN images of diagnostic value were demonstrated, with 2.5 mm isotropic resolutions achieved in 3 min scans. This performance took advantage of the low specific absorption rate and relative long TEs associated with low-field MRI. CONCLUSION: SPEN MRI provides a robust and advantageous fast acquisition approach to obtain faithful 3D images and DWI data in low-cost, portable, low-field systems without parallel acceleration.


Assuntos
Encéfalo , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Humanos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Reprodutibilidade dos Testes , Algoritmos , Aumento da Imagem/métodos , Sensibilidade e Especificidade , Análise Espaço-Temporal , Processamento de Sinais Assistido por Computador , Imagem Ecoplanar , Análise de Falha de Equipamento , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Difusão por Ressonância Magnética
7.
Sensors (Basel) ; 24(8)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38676023

RESUMO

In the human-robot collaboration system, the high-precision distortion correction of the camera as an important sensor is a crucial prerequisite for accomplishing the task. The traditional correction process is to calculate the lens distortion with the camera model parameters or separately from the camera model. However, in the optimization process calculate with the camera model parameters, the mutual compensation between the parameters may lead to numerical instability, and the existing distortion correction methods separated from the camera model are difficult to ensure the accuracy of the correction. To address this problem, this study proposes a model-independent lens distortion correction method based on the image center area from the perspective of the actual camera lens distortion principle. The proposed method is based on the idea that the structured image preserves its ratios through perspective transformation, and uses the local image information in the central area of the image to correct the overall image. The experiments are verified from two cases of low distortion and high distortion under simulation and actual experiments. The experimental results show that the accuracy and stability of this method are better than other methods in training and testing results.

8.
Diagnostics (Basel) ; 14(5)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38473039

RESUMO

Single-plane fluoroscopy systems with image intensifiers remain commonly employed in a clinical setting. The imagery they capture is vulnerable to several types of geometric distortions introduced by the system's components and their assembly as well as interactions with the local and global magnetic fields. In this study, the application of a self-calibrating bundle adjustment is investigated as a method to correct geometric distortions in single-plane fluoroscopic imaging systems. The resulting calibrated imagery is then applied in the quantitative analysis of diaphragmatic motion and potential diagnostic applications to hemidiaphragm paralysis. The calibrated imagery is further explored and discussed in its potential impact on areas of surgical navigation. This work was accomplished through the application of a controlled experiment with three separate Philips Easy Diagnost R/F Systems. A highly redundant (~2500 to 3500 degrees-of-freedom) and geometrically strong network of 18 to 22 images of a low-cost target field was collected. The target field comprised 121 pre-surveyed tantalum beads embedded on a 25.4 mm × 25.4 mm acrylic base plate. The modeling process resulted in the estimation of five to eight distortion coefficients, depending on the system. The addition of these terms resulted in 83-85% improvement in terms of image point precision (model fit) and 85-95% improvement in 3D object reconstruction accuracy after calibration. This study demonstrates significant potential in enhancing the accuracy and reliability of fluoroscopic imaging, thereby improving the overall quality and effectiveness of medical diagnostics and treatments.

9.
Magn Reson Imaging ; 108: 11-21, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38309376

RESUMO

Diffusion MRI of the spinal cord (SC) is susceptible to geometric distortion caused by field inhomogeneities, and prone to misalignment across time series and signal dropout caused by biological motion. Several modifications of image acquisition and image processing techniques have been introduced to overcome these artifacts, but their specific benefits are largely unproven and warrant further investigations. We aim to evaluate two specific aspects of image acquisition and processing that address image quality in diffusion studies of the spinal cord: susceptibility corrections to reduce geometric distortions, and cardiac triggering to minimize motion artifacts. First, we evaluate 4 distortion preprocessing strategies on 7 datasets of the cervical and lumbar SC and find that while distortion correction techniques increase geometric similarity to structural images, they are largely driven by the high-contrast cerebrospinal fluid, and do not consistently improve the geometry within the cord nor improve white-to-gray matter contrast. We recommend at a minimum to perform bulk-motion correction in preprocessing and posit that improvements/adaptations are needed for spinal cord distortion preprocessing algorithms, which are currently optimized and designed for brain imaging. Second, we design experiments to evaluate the impact of removing cardiac triggering. We show that when triggering is foregone, images are qualitatively similar to triggered sequences, do not have increased prevalence of artifacts, and result in similar diffusion tensor indices with similar reproducibility to triggered acquisitions. When triggering is removed, much shorter acquisitions are possible, which are also qualitatively and quantitatively similar to triggered sequences. We suggest that removing cardiac triggering for cervical SC diffusion can be a reasonable option to save time with minimal sacrifice to image quality.


Assuntos
Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes , Processamento de Imagem Assistida por Computador/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Medula Espinal/diagnóstico por imagem , Encéfalo , Algoritmos , Artefatos , Imagem Ecoplanar/métodos
10.
Magn Reson Med ; 92(1): 82-97, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38308081

RESUMO

PURPOSE: To develop a method for dynamic ∆ B 0 $$ \Delta {B}_0 $$ mapping and distortion correction. METHODS: A blip-rewound EPI trajectory was developed to acquire multiple 2D EPI images in a single readout with an interleaved order, which allows a short TE difference. A joint multi-echo reconstruction was utilized to exploit the shared information between EPI images. The reconstructed images from each readout are combined to produce a final magnitude image. A ∆ B 0 $$ \Delta {B}_0 $$ map is calculated from the phase of these images for distortion correction. The efficacy of the proposed method is assessed with phantom and in vivo experiments. The performance of the proposed method in the presence of subject motion is also investigated. RESULTS: Compared to conventional multi-echo EPI, the proposed method allows dynamic ∆ B 0 $$ \Delta {B}_0 $$ mapping at matched resolution with a much shorter TR. Phantom and in vivo results show that the proposed method can provide a comparable magnitude image as conventional single-shot EPI. The ∆ B 0 $$ \Delta {B}_0 $$ maps calculated from the proposed method are consistent with conventional multi-echo EPI in the phantom experiment. For in vivo experiments, the proposed method provides a more accurate estimation of ∆ B 0 $$ \Delta {B}_0 $$ than conventional multi-echo EPI, which is prone to phase wrapping problems due to the long TE difference. In-vivo scan with subject motion shows the proposed dynamic field mapping method can improve the temporal stability of EPI time series compared to gradient echo (GRE) based static field mapping. CONCLUSION: The proposed method allows accurate dynamic ∆ B 0 $$ \Delta {B}_0 $$ mapping for robust distortion correction without compromising spatial or temporal resolution.


Assuntos
Algoritmos , Imagem Ecoplanar , Imagens de Fantasmas , Humanos , Imagem Ecoplanar/métodos , Artefatos , Reprodutibilidade dos Testes , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Encéfalo/diagnóstico por imagem , Sensibilidade e Especificidade
11.
Magn Reson Med ; 91(6): 2546-2558, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38376096

RESUMO

PURPOSE: We aimed to develop a free-breathing (FB) cardiac DTI (cDTI) method based on short-axis PROPELLER (SAP) and M2 motion compensated spin-echo EPI (SAP-M2-EPI) to mitigate geometric distortion and eliminate aliasing in acquired diffusion-weighted (DW) images, particularly in patients with a higher body mass index (BMI). THEORY AND METHODS: The study involved 10 healthy volunteers whose BMI values fell into specific categories: BMI <25 (4 volunteers), 25< BMI <28 (5 volunteers), and BMI >30 (1 volunteer). We compared DTI parameters, including fractional anisotropy (FA), mean diffusivity (MD), and helix angle transmurality (HAT), between SAP-M2-EPI and M2-ssEPI. To evaluate the performance of SAP-M2-EPI in reducing geometric distortions in the left ventricle (LV) compared to CINE and M2-ssEPI, we utilized the DICE similarity coefficient (DSC) and assessed misregistration area. RESULTS: In all volunteers, SAP-M2-EPI yielded high-quality LV DWIs without aliasing, demonstrating significantly reduced geometric distortion (with an average DSC of 0.92 and average misregistration area of 90 mm2) and diminished signal loss due to bulk motion when compared to M2-ssEPI. DTI parameter maps exhibited consistent patterns across slices without motion related artifacts. CONCLUSION: SAP-M2-EPI facilitates free-breathing cDTI of the entire LV, effectively eliminating aliasing and minimizing geometric distortion compared to M2-ssEPI. Furthermore, it preserves accurate quantification of myocardial microstructure.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Humanos , Estudos de Viabilidade , Imagem de Tensor de Difusão/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Imagem Ecoplanar/métodos
12.
NMR Biomed ; 37(1): e5034, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37681398

RESUMO

Functional magnetic resonance imaging (fMRI) in awake small animals such as pigeons or songbirds opens a new window into the neural fundaments of cognitive behavior. However, high-field fMRI in the avian brain is challenging due to strong local magnetic field inhomogeneities caused by air cavities in the skull. A spoiled gradient-echo fMRI sequence has already been used to map the auditory network in songbirds, but due to susceptibility artifacts only 50% of the whole brain could be recorded. Since whole-brain fMRI coverage is vital to reveal whole-brain networks, an MRI sequence that is less susceptible to these artifacts was required. This was recently achieved in various bird species by using a rapid acquisition with relaxation enhancement (RARE) sequence. Weak blood oxygen level-dependent (BOLD) sensitivity, low temporal resolution, and heat caused by the long train of RF refocusing pulses are the main limits of RARE fMRI at high magnetic fields. To go beyond some of these limitations, we here describe the implementation of a two-segmented spin-echo echo-planar imaging (SE-EPI). The proposed sequence covers the whole brain of awake pigeons. The sequence was applied to investigate the auditory network in awake pigeons and assessed the relative merits of this method in comparison with the single-shot RARE sequence. At the same imaging resolution but with a volume acquisition of 3 s versus 4 s for RARE, the two-segmented SE-EPI provided twice the strength of BOLD activity compared with the single-shot RARE sequence, while the image signal-to-noise ratio (SNR) and in particular the temporal SNR were very similar for the two sequences. In addition, the activation patterns in two-segmented SE-EPI data are more symmetric and larger than single-shot RARE results. Two-segmented SE-EPI represents a valid alternative to the RARE sequence in avian fMRI research since it yields more than twice the BOLD sensitivity per unit of time with much less energy deposition and better temporal resolution, particularly for event-related experiments.


Assuntos
Columbidae , Imagem Ecoplanar , Animais , Imagem Ecoplanar/métodos , Vigília , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia
13.
bioRxiv ; 2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38077010

RESUMO

Functional MRI (fMRI) data are severely distorted by magnetic field (B0) inhomogeneities which currently must be corrected using separately acquired field map data. However, changes in the head position of a scanning participant across fMRI frames can cause changes in the B0 field, preventing accurate correction of geometric distortions. Additionally, field maps can be corrupted by movement during their acquisition, preventing distortion correction altogether. In this study, we use phase information from multi-echo (ME) fMRI data to dynamically sample distortion due to fluctuating B0 field inhomogeneity across frames by acquiring multiple echoes during a single EPI readout. Our distortion correction approach, MEDIC (Multi-Echo DIstortion Correction), accurately estimates B0 related distortions for each frame of multi-echo fMRI data. Here, we demonstrate that MEDIC's framewise distortion correction produces improved alignment to anatomy and decreases the impact of head motion on resting-state functional connectivity (RSFC) maps, in higher motion data, when compared to the prior gold standard approach (i.e., TOPUP). Enhanced framewise distortion correction with MEDIC, without the requirement for field map collection, furthers the advantage of multi-echo over single-echo fMRI.

14.
Brain Spine ; 3: 102685, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38021010

RESUMO

Introduction: The resection of brainstem cerebral cavernous malformations (CCM) harbors the risk of damaging the corticospinal tract (CST) and other major tracts. Hence, visualization of eloquent fiber tracts supports pre- and intraoperative planning. However, diffusion tensor imaging fiber tracking at brainstem level suffers from distortion due to field inhomogeneities and eddy currents by steep diffusion gradients. Research question: This study aims to analyze the effect of distortion correction for CST tractography in brainstem CCM patients. Material and methods: 25 patients who underwent resection of brainstem CCM were enrolled, 24 suffered from hemorrhage. We performed an anatomically based tractography of the CST with a mean minimal fractional anisotropy of 0.22 ± 0.04 before and after cranial distortion correction (CDC). Accuracy was measured by anatomical plausibility and aberrant fibers. Results: CDC led to a more precise CST tractography, further approximating its assumed anatomical localization in all cases. CDC resulted in a significantly more ventral location of the CST of 1.5 ± 0.6 mm (6.1 ± 2.7 mm before CDC vs. 4.6 ± 2.1 mm after CDC; p < .0001) as measured by the distance to the basilar artery and of 1.7 ± 0.6 mm (8.9 ± 2.7 mm vs. 7.2 ± 2.1 mm; p < .0001) in relation to the clivus. Aberrant fibers were reduced by CDC in 44% of cases. We found a mean difference in CST volume of 0.6 ± 0.8 ccm. We could not detect motor deficits after resection of irregular fibers. Discussion and conclusion: CDC effectively corrects tractography for distortion at brainstem level, especially in patients suffering from brainstem CCM, further approximating its actual anatomical localization.

15.
Magn Reson Med Sci ; 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37952942

RESUMO

PURPOSE: To compare image distortion and reproducibility of quantitative values between reverse encoding distortion correction (RDC) diffusion-weighted imaging (DWI) and conventional DWI techniques in a phantom study and in healthy volunteers. METHODS: This prospective study was conducted with the approval of our institutional review board. Written informed consent was obtained from each participant. RDC-DWIs were created from images obtained at 3T in three orthogonal directions in a phantom and in 10 participants (mean age, 70.9 years; age range, 63-83 years). Images without distortion correction (noDC-DWI) and those corrected with B0 (B0c-DWI) were also created. To evaluate distortion, coefficients of variation were calculated for each voxel and ROIs were placed at four levels of the brain. To evaluate the reproducibility of apparent diffusion coefficient (ADC) measurements, intra- and inter-scan variability (%CVADC) were calculated from repeated scans of the phantom. Analysis was performed using Wilcoxon signed-rank test with Bonferroni correction, and P < 0.05 was considered statistically significant. RESULTS: In the phantom, distortion was less in RDC-DWI than in B0c-DWI (P < 0.006), and was less in B0c-DWI than in noDC-DWI (P < 0.006). Intra-scan %CVADC was within 1.30%, and inter-scan %CVADC was within 2.99%. In the volunteers, distortion was less in RDC-DWI than in B0c-DWI in three of four locations (P < 0.006), and was less in B0c-DWI than in noDC-DWI (P < 0.006). At the middle cerebellar peduncle, distortion was less in RDC-DWI than in noDC-DWI (P < 0.006), and was less in noDC-DWI than in B0c-DWI (P < 0.0177). CONCLUSION: In both the phantom and in volunteers, distortion was the least in RDC-DWI than in B0c-DWI and noDC-DWI.

16.
Magn Reson Med ; 90(6): 2375-2387, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37667533

RESUMO

PURPOSE: EPI with blip-up/down acquisition (BUDA) can provide high-quality images with minimal distortions by using two readout trains with opposing phase-encoding gradients. Because of the need for two separate acquisitions, BUDA doubles the scan time and degrades the temporal resolution when compared to single-shot EPI, presenting a major challenge for many applications, particularly fMRI. This study aims at overcoming this challenge by developing an echo-shifted EPI BUDA (esEPI-BUDA) technique to acquire both blip-up and blip-down datasets in a single shot. METHODS: A 3D esEPI-BUDA pulse sequence was designed by using an echo-shifting strategy to produce two EPI readout trains. These readout trains produced a pair of k-space datasets whose k-space trajectories were interleaved with opposite phase-encoding gradient directions. The two k-space datasets were separately reconstructed using a 3D SENSE algorithm, from which time-resolved B0 -field maps were derived using TOPUP in FSL and then input into a forward model of joint parallel imaging reconstruction to correct for geometric distortion. In addition, Hankel structured low-rank constraint was incorporated into the reconstruction framework to improve image quality by mitigating the phase errors between the two interleaved k-space datasets. RESULTS: The 3D esEPI-BUDA technique was demonstrated in a phantom and an fMRI study on healthy human subjects. Geometric distortions were effectively corrected in both phantom and human brain images. In the fMRI study, the visual activation volumes and their BOLD responses were comparable to those from conventional 3D echo-planar images. CONCLUSION: The improved imaging efficiency and dynamic distortion correction capability afforded by 3D esEPI-BUDA are expected to benefit many EPI applications.


Assuntos
Algoritmos , Artroplastia de Substituição , Humanos , Encéfalo/diagnóstico por imagem , Voluntários Saudáveis , Imagens de Fantasmas
17.
Hum Brain Mapp ; 44(15): 5095-5112, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37548414

RESUMO

The boundaries between tissues with different magnetic susceptibilities generate inhomogeneities in the main magnetic field which change over time due to motion, respiration and system instabilities. The dynamically changing field can be measured from the phase of the fMRI data and corrected. However, methods for doing so need multi-echo data, time-consuming reference scans and/or involve error-prone processing steps, such as phase unwrapping, which are difficult to implement robustly on the MRI host. The improved dynamic distortion correction method we propose is based on the phase of the single-echo EPI data acquired for fMRI, phase offsets calculated from a triple-echo, bipolar reference scan of circa 3-10 s duration using a method which avoids the need for phase unwrapping and an additional correction derived from one EPI volume in which the readout direction is reversed. This Reverse-Encoded First Image and Low resoLution reference scan (REFILL) approach is shown to accurately measure B0 as it changes due to shim, motion and respiration, even with large dynamic changes to the field at 7 T, where it led to a > 20% increase in time-series signal to noise ratio compared to data corrected with the classic static approach. fMRI results from REFILL-corrected data were free of stimulus-correlated distortion artefacts seen when data were corrected with static field mapping. The method is insensitive to shim changes and eddy current differences between the reference scan and the fMRI time series, and employs calculation steps that are simple and robust, allowing most data processing to be performed in real time on the scanner image reconstruction computer. These improvements make it feasible to routinely perform dynamic distortion correction in fMRI.


Assuntos
Mapeamento Encefálico , Encéfalo , Imagem Ecoplanar , Humanos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico/métodos , Imagem Ecoplanar/métodos , Artefatos
18.
Magn Reson Imaging ; 103: 18-27, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37400042

RESUMO

Functional magnetic resonance images (fMRI) acquired using echo planar sequences typically suffer from spatial distortions due to susceptibility induced off-resonance fields, which may cause geometric mismatch with structural images and affect subsequent quantification and localization of brain function. State-of-the art distortion correction methods (for example, using FSL's topup or AFNI's 3dQwarp algorithms) require the collection of additional scans - either field maps or images with reverse phase encoding directions (i.e., blip-up/blip-down acquisitions) - to estimate and correct distortions. However, not all imaging protocols acquire these additional data and thus cannot take advantage of these post-acquisition corrections. In this study, we aim to enable state-of-the art processing of historical or limited datasets that do not include specific sequences for distortion correction by using only the acquired functional data and a single commonly acquired structural image. To achieve this, we synthesize an undistorted image with contrast similar to the fMRI data and use the non-distorted synthetic image as an anatomical target for distortion correction. We evaluate the efficacy of this approach, named SynBOLD-DisCo (Synthetic BOLD contrast for Distortion Correction), and show that this distortion correction process yields fMRI data that are geometrically similar to non-distorted structural images, with distortion correction virtually equivalent to acquisitions that do contain both blip-up/blip-down images. Our method is available as a Singularity container, source code, and an executable trained model to facilitate evaluation and integration into existing fMRI preprocessing pipelines.


Assuntos
Imagem Ecoplanar , Processamento de Imagem Assistida por Computador , Imagem Ecoplanar/métodos , Processamento de Imagem Assistida por Computador/métodos , Artefatos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Encéfalo/diagnóstico por imagem
19.
Sensors (Basel) ; 23(14)2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37514683

RESUMO

To solve the problems of spectral tomography, an X-ray optical scheme was proposed, using a crystal analyzer in Laue geometry between the sample and the detector, which allowed for the selection of predetermined pairs of wavelengths from the incident polychromatic radiation to obtain projection images. On a laboratory X-ray microtomography setup, an experiment was carried out for the first time where a mixture of micro-granules of sodium chloride NaCl, silver behenate AgC22H43O2, and lithium niobate LiNbO3 was used as a test sample to identify their spatial arrangement. The elements were chosen based on the presence of absorption edges in two of the elements in the energy range of the polychromatic spectrum of the probing radiation. The method of projection distortion correction was used to preprocess the obtained projections. To interpret the obtained reconstruction results, the segmentation method based on the analysis of joint histograms was used. This allowed us to identify each of the three substances. To compare the results obtained, additional "reference" tomographic measurements were performed: one in polychromatic and two in monochromatic (MoKα-, MoKß-lines) modes. It took three times less time for the tomographic experiment with the crystal analyzer, while the reconstruction accuracy was comparable to that of the "reference" tomography.

20.
Neuroimage ; 279: 120294, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37517572

RESUMO

Geometric distortion is a major limiting factor for spatial specificity in high-resolution fMRI using EPI readouts and is exacerbated at higher field strengths due to increased B0 field inhomogeneity. Prominent correction schemes are based on B0 field-mapping or acquiring reverse phase-encoded (reversed-PE) data. However, to date, comparisons of these techniques in the context of fMRI have only been performed on 2DEPI data, either at lower field or lower resolution. In this study, we investigate distortion compensation in the context of sub-millimetre 3DEPI data at 7T. B0 field-mapping and reversed-PE distortion correction techniques were applied to both partial coverage BOLD-weighted and whole brain MT-weighted 3DEPI data with matched distortion. Qualitative assessment showed overall improvement in cortical alignment for both correction techniques in both 3DEPI fMRI and whole-brain MT-3DEPI datasets. The distortion-corrected MT-3DEPI images were quantitatively evaluated by comparing cortical alignment with an anatomical reference using dice coefficient (DC) and correlation ratio (CR) measures. These showed that B0 field-mapping and reversed-PE methods both improved correspondence between the MT-3DEPI and anatomical data, with more substantial improvements consistently obtained using the reversed-PE approach. Regional analyses demonstrated that the largest benefit of distortion correction, and in particular of the reversed-PE approach, occurred in frontal and temporal regions where susceptibility-induced distortions are known to be greatest, but had not led to complete signal dropout. In conclusion, distortion correction based on reversed-PE data has shown the greater capacity for achieving faithful alignment with anatomical data in the context of high-resolution fMRI at 7T using 3DEPI.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Processamento de Imagem Assistida por Computador/métodos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico/métodos , Artefatos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA