Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 381
Filtrar
1.
Sensors (Basel) ; 24(19)2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39409281

RESUMO

Magnetic nanoparticles (MNPs) can be functionalized with antibodies to give them an affinity for a biomarker of interest. Functionalized MNPs (fMNPs) cluster in the presence of a multivalent target, causing a change in their magnetization. Target concentration can be proportional to the 3rd harmonic phase of the fMNP magnetization signal. fMNP clustering can also be induced with salt. Generally, salt can alter the stability of charge stabilized fMNPs causing a change in magnetization that is not proportional to the target concentration. We have developed a model system consisting of biotinylated MNPs (biotin-MNPs) that target streptavidin to study the effects of salt concentration on fMNP-based biosensing in simulated in vivo conditions. We have found that biotin-MNP streptavidin targeting was independent of salt concentration for 0.005x to 1.00x phosphate buffered saline (PBS) solutions. Additionally, we show that our biosensor's measurable concentration range (dynamic range) can be tuned with biotin density. Our results can be leveraged to design an in vivo nanoparticle (NP)-based biosensor with enhanced efficacy in the event of varying salt concentrations.


Assuntos
Técnicas Biossensoriais , Biotina , Nanopartículas de Magnetita , Estreptavidina , Técnicas Biossensoriais/métodos , Nanopartículas de Magnetita/química , Biotina/química , Estreptavidina/química , Sais/química , Cloreto de Sódio/química
2.
Sensors (Basel) ; 24(18)2024 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-39338621

RESUMO

Stereo high dynamic range imaging (SHDRI) offers a more temporally stable solution to high dynamic range (HDR) imaging from low dynamic range input images compared to bracketing and removes the loss of accuracy that single-image HDR solutions offer. However, few solutions currently exist that take advantage of the different (asymmetric) lenses, commonly found on modern smartphones, to achieve SHDRI. This paper presents a method that achieves single-shot asymmetric HDR fusion via a reference-based deep learning approach. Results demonstrate a system that is more robust to aperture and image signal processing pipeline differences than existing solutions.

3.
Biosens Bioelectron ; 266: 116736, 2024 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-39226751

RESUMO

In photoelectrochemical (PEC) sensors, traditional detection modes such as "signal-on", "signal-off", and "polarity-switchable" limit target signals to a single polarity range, necessitating novel design strategies to enhance the operational scope. To overcome this limitation, we propose, for the first time, a "polarity-transcendent" design concept that enables a continuous response across the polarity spectrum, significantly broadening the sensor's concentration detection range. This concept is exemplified in our new "background-enhanced signal-off polarity-switchable" (BESOPS) mode, where the model analyte let-7a activates a cascade shearing reaction of a DNAzyme walker in conjunction with CRISPR/Cas12a, quantitatively peeling off Cu2O-H2 strands at the Cu2O/TiO2 electrode interface to expose the TiO2 surface. This exposure generates an anodic photocurrent at the expense of the cathodic photocurrent from Cu2O/TiO2, facilitating a seamless transition of the target signal from cathodic to anodic. Through systematic experiments and comparative analyses, the BESOPS sensor demonstrates highly sensitive and precise quantification of let-7a, with a detection limit of 2.5 aM and a broad operating range of 10 aM to 10 nM. Its performance exceeds most reported sensor platforms, highlighting the significant potential of our polarity-transcendent design in expanding the operational range of PEC sensors. This innovative approach paves the way for developing next-generation PEC sensors with enhanced applicability and heightened sensitivity in various critical fields.


Assuntos
Técnicas Biossensoriais , Cobre , Técnicas Eletroquímicas , Limite de Detecção , Titânio , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/métodos , Cobre/química , Titânio/química , MicroRNAs/análise , Humanos , Desenho de Equipamento , Sistemas CRISPR-Cas , Eletrodos
4.
Hear Res ; 453: 109120, 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39306941

RESUMO

Exposure to loud sound during leisure time is identified as a significant risk factor for hearing by health authorities worldwide. The current standard that defines unsafe exposure rests on the equal-energy hypothesis, according to which the maximum recommended exposure is a tradeoff between level and daily exposure duration, a satisfactory recipe except for strongly non-Gaussian intense sounds such as gunshots. Nowadays, sound broadcast by music and videoconference streaming services makes extensive use of numerical dynamic range compression. By filling in millisecond-long valleys in the signal to prevent competing noise from masking, it pulls sound-level statistics away from a Gaussian distribution, the framework where the equal-energy hypothesis emerged. Auditory effects of a single 4 hour exposure to the same music were compared in two samples of guinea pigs exposed either to its original or overcompressed version played at the same average level of 102 dBA allowed by French regulations. Apart from a temporary shift of otoacoustic emissions at the lowest two frequencies 2 and 3 kHz, music exposure had no detectable cochlear effect, as monitored at 1, 2 and 7 days post-exposure. Conversely, middle-ear muscle strength behaved differentially as the group exposed to original music had fully recovered one day after exposure whereas the group exposed to overcompressed music remained stuck to about 50% of baseline even after 7 days. Subsamples were then re-exposed to the same music as the first time and sacrificed for density measurements of inner-hair-cell synapses. No difference in synaptic density was found compared to unexposed controls with either type of music. The present results show that the same music piece, harmless when played in its original version, induces a protracted deficit of one auditory neural pathway when overcompressed at the same level. The induced disorder does not seem to involve inner-hair cell synapses.

5.
J Appl Clin Med Phys ; 25(10): e14481, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39133939

RESUMO

This investigation aimed to optimize gradient positioning for radiochromic film calibration to facilitate a uniform distribution of calibration points. The study investigated the influence of various parameters on gradient dose profiles generated by a physical wedge, assessing their impact on the field's dose dynamic range, a scalar quantity representing the span of absorbed doses. Numerical parameterization of the physical wedge profile was used to visualize and quantify the impact of field size, depth, and energy on the dynamic range of dose gradients. This concept enabled the optimization of the gradient positioning and estimation of the necessary number of exposures for the desired calibration dose range. An optimization algorithm based on histogram bin height minimization was developed and presented. The maximum dynamic range was achieved with a 20 × $\times$ 20 cm 2 $\textrm {cm}^{2}$ field size at 5 cm depth. Optimization of wedge gradient positioning yielded the most uniform dose distribution with 7 exposures for the [1,10] Gy range and 8 exposures for the [1,20] Gy range. Film calibration using gradients centered at 1.6, 3, 3.5, and 7 Gy central axis (CAX), obtained through optimized gradient positioning, was showcased. The presented work demonstrates the potential for an improved film calibration process, with efficient material utilization and enhanced dosimetric accuracy for clinical applications. While the method was described for the use of a physical wedge, the methodology can be easily extended to the use of a more convenient dynamic wedge.


Assuntos
Algoritmos , Dosimetria Fotográfica , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Calibragem , Dosimetria Fotográfica/métodos , Dosimetria Fotográfica/instrumentação , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Imagens de Fantasmas , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/normas
6.
MethodsX ; 13: 102857, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39105094

RESUMO

We increase the dynamical range of a scanning tunneling microscope (STM) by actively subtracting dominant current-harmonics generated by nonlinearities in the current-voltage characteristics that could saturate the current preamplifier at low junction impedances or high gains. The strict phase relationship between a cosinusoidal excitation voltage and the current-harmonics allows excellent cancellation using the displacement-current of a driven compensating capacitor placed at the input of the preamplifier. Removal of DC currents has no effect on, and removal of the first harmonic only leads to a rigid shift in differential conductance that can be numerically reversed by adding the known removal current. Our method requires no permanent change of the hardware but only two phase synchronized voltage sources and a multi-frequency lock-in amplifier to enable high dynamic range spectroscopy and imaging. • Active power filter • Dynamic range compression • High gain preamplifier.

7.
Sensors (Basel) ; 24(15)2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39124018

RESUMO

The present study deals with image enhancement, which is a very common problem in image processing. This issue has been addressed in multiple works with different methods, most with the sole purpose of improving the perceived quality. Our goal is to propose an approach with a strong physical justification that can model the human visual system. This is why the Logarithmic Image Processing (LIP) framework was chosen. Within this model, initially dedicated to images acquired in transmission, it is possible to introduce the novel concept of negative grey levels, interpreted as light intensifiers. Such an approach permits the extension of the dynamic range of a low-light image to the full grey scale in "real-time", which means at camera speed. In addition, this method is easily generalizable to colour images and is reversible, i.e., bijective in the mathematical sense, and can be applied to images acquired in reflection thanks to the consistency of the LIP framework with human vision. Various application examples are presented, as well as prospects for extending this work.

8.
Data Brief ; 55: 110755, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39149717

RESUMO

This paper describes three datasets which include 443 folders and approximately 4430 images. The images were obtained from the interior of a 1:50 scale model using a fisheye camera connected to a Raspberry Pi microcomputer. This dataset aims to analyze the photobiological effects (visual and non-visual) of the interplay between coloured surfaces and different types of lighting strategies. The experiments were conducted under three types of light sources: simulated daylight through a mirror-box artificial sky simulator, direct daylight, and an electric lighting system that allows for colour temperature modification. This dataset includes low dynamic range images to generate high dynamic range images, which in turn can be used to plot false colour maps concerning photopic luminance, melanopic luminance, CCT of an image, M/P ratio, and brightness distribution maps. This dataset can be useful for architects, interior designers, and building engineers to integrate lighting and colour strategies according to the visual and non-visual needs of the users. This research was partially used in the research of Espinoza-Sanhueza et al. [1,2]. The datasets are published and shared through a Mendeley repository [3].

9.
Sci Rep ; 14(1): 15176, 2024 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956114

RESUMO

Assessing programmed death ligand 1 (PD-L1) expression through immunohistochemistry (IHC) is the golden standard in predicting immunotherapy response of non-small cell lung cancer (NSCLC). However, observation of heterogeneous PD-L1 distribution in tumor space is a challenge using IHC only. Meanwhile, immunofluorescence (IF) could support both planar and three-dimensional (3D) histological analyses by combining tissue optical clearing with confocal microscopy. We optimized clinical tissue preparation for the IF assay focusing on staining, imaging, and post-processing to achieve quality identical to traditional IHC assay. To overcome limited dynamic range of the fluorescence microscope's detection system, we incorporated a high dynamic range (HDR) algorithm to restore the post imaging IF expression pattern and further 3D IF images. Following HDR processing, a noticeable improvement in the accuracy of diagnosis (85.7%) was achieved using IF images by pathologists. Moreover, 3D IF images revealed a 25% change in tumor proportion score for PD-L1 expression at various depths within tumors. We have established an optimal and reproducible process for PD-L1 IF images in NSCLC, yielding high quality data comparable to traditional IHC assays. The ability to discern accurate spatial PD-L1 distribution through 3D pathology analysis could provide more precise evaluation and prediction for immunotherapy targeting advanced NSCLC.


Assuntos
Antígeno B7-H1 , Carcinoma Pulmonar de Células não Pequenas , Imunofluorescência , Imageamento Tridimensional , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Carcinoma Pulmonar de Células não Pequenas/patologia , Antígeno B7-H1/metabolismo , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/diagnóstico , Imageamento Tridimensional/métodos , Imunofluorescência/métodos , Imuno-Histoquímica/métodos , Microscopia Confocal/métodos , Biomarcadores Tumorais/metabolismo
10.
Sensors (Basel) ; 24(13)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-39000838

RESUMO

Array pattern synthesis with low sidelobe levels is widely used in practice. An effective way to incorporate sensor patterns in the design procedure is to use numerical optimization methods. However, the dimension of the optimization variables is very high for large-scale arrays, leading to high computational complexity. Fortunately, sensor arrays used in practice usually have symmetric structures that can be utilized to accelerate the optimization algorithms. This paper studies a fast pattern synthesis method by using the symmetry of array geometry. In this method, the problem of amplitude weighting is formulated as a second-order cone programming (SOCP) problem, in which the dynamic range of the weighting coefficients can also be taken into account. Then, by utilizing the symmetric property of array geometry, the dimension of the optimization problem as well as the number of constraints can be reduced significantly. As a consequence, the computational efficiency is greatly improved. Numerical experiments show that, for a uniform rectangular array (URA) with 1024 sensors, the computational efficiency is improved by a factor of 158, while for a uniform hexagonal array (UHA) with 1261 sensors, the improvement factor is 284.

11.
Data Brief ; 55: 110658, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39049970

RESUMO

This paper details an imagery dataset of interior and exterior ambiances to assess and represent photobiological outcomes of the built environment in northern territories. The images were obtained using a Raspberry Pi Camera Module (RPiCM) mounted in a holder that fixes the camera in place. This holder allows to rotate the camera by 30° and take 12 high dynamic range (HDR) images which are then combined to create a panoramic image. The HDR images enable the calculation of photobiological effects concerning photopic light intensity for vision, and the spectral dominance regarding vision and circadian stimulation. This dataset includes 13 captures in 7 interior and 6 exterior settings, each divided into 4 subfolders containing the photographic data: the sequence of low-dynamic range images (LDR), the tone-mapped images obtained from the HDR calculation, the analysis of photopic luminance and false color, and 360° panoramic images (tone-mapped HDR, false color luminance, and spectral dominance). Each space is also supplemented with photometric data presented as a .csv file containing lux and EML units obtained via a radiometer. This dataset is valuable for architects, designers, and neuroscientists to identify opportunities for enhancing human-centric lighting in existing architecture and landscape, as well as to propose solutions that promote vision and circadian stimulation in northern territories. This research was partially used in previous studies from [10]. The dataset is published and shared through a Mendeley repository [9].

12.
Sensors (Basel) ; 24(11)2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38894187

RESUMO

Ambient light sensors are becoming increasingly popular due to their effectiveness in extending the battery life of portable electronic devices. However, conventional ambient light sensors are large in area and small in dynamic range, and they do not take into account the effects caused due to a dark current. To address the above problems, a programmable ambient light sensor with dark current compensation and a wide dynamic range is proposed in this paper. The proposed ambient light sensor exhibits a low current power consumption of only 7.7 µA in dark environments, and it operates across a wide voltage range (2-5 V) and temperature range (-40-80 °C). It senses ambient light and provides an output current proportional to the ambient light intensity, with built-in dark current compensation to effectively suppress the effects of a dark current. It provides a wide dynamic range over the entire operating temperature range with three selectable output-current gain modes. The proposed ambient light sensor was designed and fabricated using a 0.18 µm standard CMOS process, and the effective area of the chip is 663 µm × 652 µm. The effectiveness of the circuit was verified through testing, making it highly suitable for portable electronic products and fluorescent fiber-optic temperature sensors.

13.
Int J Audiol ; : 1-8, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38832702

RESUMO

OBJECTIVE: The dynamic range (DR) available to the patient is a central parameter to determine speech intelligibility in quiet. DESIGN: In this retrospective study, the DR for the Vibrant Soundbridge implanted in individual patients was calculated using in situ thresholds of the patients and technical data of the implant system. The average DR across frequencies (0.5, 1, 2, 4 kHz) was correlated with the patients' assigned word recognition score (WRS) in quiet. STUDY SAMPLE: A data set of 66 cases (4 bilateral and 2 revised cases) from 60 implanted patients between 14.3-81.8 years were analysed. RESULTS: The relationship between DR and WRS was described by a sigmoidal growth function with R2=0.6371 and a maximum WRS (upper asymptote) of 93.5%. Word recognition scores in quiet improved with increasing DR. A significant shift in performance was detected from DR bin 2 (10-20 dB, median WRS 55%) to bin 3 (20-30 dB, median WRS 80%) and from DR bin 4 (30-40 dB, median WRS 82.5%) to bin 5 (40-50 dB, median WRS 90%). CONCLUSION: A minimum DR of 20 dB can yield sufficient speech intelligibility in quiet in implanted patients, however, an optimum DR is suggested to be 40 dB.

14.
Sensors (Basel) ; 24(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38732834

RESUMO

The Shack-Hartmann wavefront sensor (SHWFS) is widely utilized for ocular aberration measurement. However, large ocular aberrations caused by individual differences can easily make the spot move out of the range of the corresponding sub-aperture in SHWFS, rendering the traditional centroiding method ineffective. This study applied a novel convolutional neural network (CNN) model to wavefront sensing for large dynamic ocular aberration measurement. The simulation results demonstrate that, compared to the modal method, the dynamic range of our method for main low-order aberrations in ocular system is increased by 1.86 to 43.88 times in variety. Meanwhile, the proposed method also has the best measurement accuracy, and the statistical root mean square (RMS) of the residual wavefronts is 0.0082 ± 0.0185 λ (mean ± standard deviation). The proposed method generally has a higher accuracy while having a similar or even better dynamic range as compared to traditional large-dynamic schemes. On the other hand, compared with recently developed deep learning methods, the proposed method has a much larger dynamic range and better measurement accuracy.

15.
Zhen Ci Yan Jiu ; 49(5): 448-455, 2024 May 25.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38764115

RESUMO

OBJECTIVES: To observe the effect of electroacupuncture (EA) at different intensities on nociceptive discharges of wide dynamic range (WDR) neurons in the spinal dorsal horns (DHs) of rats, so as to explore its regulatory characteristics on nociceptive signals at the spinal level. METHODS: A total of 25 male SD rats were used in the present study. A microelectrode array was used to record the discharge activity of WDR neurons in the lumbar spinal DHs of normal rats. After finding the WDR neuron, electrical stimulation (pulse width of 2 ms) was administered to the plantar receptive field (RF) for determining its response component of discharges according to the latency of action potential generation (Aß ï¼»0 to 20 msï¼½, Aδ ï¼»20 to 90 msï¼½, C ï¼»90 to 500 msï¼½ and post-discharge ï¼»500 to 800 msï¼½). High-intensity electrical stimulation was continuously applied to the RF at the paw's plantar surface to induce DHs neuronal windup response. Subsequently, EA stimulation at different intensities (1 mA and 2 mA) was applied to the left "Zusanli"(ST36) at a frequency of 2 Hz/15 Hz for 10 min. The induction of WDR neuronal windup was then repeated under the same conditions. The quantity of nociceptive discharge components and the windup response of WDR neurons before and after EA stimulations at different intensities were compared. RESULTS: Compared to pre-EA, both EA1 mA and EA2 mA significantly reduced the number of Aδ and C component discharges of WDR neurons during stimulation, as well as post-discharge (P<0.01, P<0.001). The inhibitory rate of C component by EA2 mA was significantly higher than that by EA1 mA (P<0.05). Meanwhile, both EA1 mA and EA2 mA attenuated the windup response of WDR neurons (P<0.05, P<0.01), and the effect of EA2 mA was stronger than that of EA1 mA (P<0.05). Further analysis showed that when EA1 mA and EA2 mA respectively applied to both non-receptive field (non-RF) and RF, a significant reduction in the number of Aδ component, C component and post-discharge was observed (P<0.05, P<0.01). EA2 mA at the non-RF and RF demonstrated a significant inhibitory effect on the windup response of WDR neurons (P<0.01, P<0.05), but EA1 mA only at the non-RF showed a significant inhibitory effect on the windup response (P<0.01). CONCLUSIONS: EA can suppress nociceptive discharges of spinal DHs WDR neurons in rats. The inhibitory impact of EA is strongly correlated with the location and intensity of EA stimulation, and EA2 mA has a stronger inhibitory effect than EA1 mA.


Assuntos
Pontos de Acupuntura , Eletroacupuntura , Ratos Sprague-Dawley , Animais , Masculino , Ratos , Humanos , Nociceptividade , Corno Dorsal da Medula Espinal/fisiopatologia , Células do Corno Posterior/fisiologia , Potenciais de Ação
16.
Micromachines (Basel) ; 15(5)2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38793235

RESUMO

High-dynamic-range integrated magnetometers demonstrate extensive potential applications in fields involving complex and changing magnetic fields. Among them, Diamond Nitrogen Vacancy Color Core Magnetometer has outstanding performance in wide-range and high-precision magnetic field measurement based on its inherent high spatial resolution, high sensitivity and other characteristics. Therefore, an innovative frequency-tracking scheme is proposed in this study, which continuously monitors the resonant frequency shift of the NV color center induced by a time-varying magnetic field and feeds it back to the microwave source. This scheme successfully expands the dynamic range to 6.4 mT, approximately 34 times the intrinsic dynamic range of the diamond nitrogen-vacancy (NV) center. Additionally, it achieves efficient detection of rapidly changing magnetic field signals at a rate of 0.038 T/s.

17.
Sensors (Basel) ; 24(10)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38793958

RESUMO

Ion mobility spectrometry (IMS) has been widely studied and applied as an effective analytical technology for the on-site detection of volatile organic compounds (VOCs). Despite its superior selectivity compared with most gas sensors, its limited dynamic range is regarded as a major drawback, limiting its further application in quantitative measurements. In this work, we proposed a novel sample introduction method based on pulsed membrane adsorption, which effectively enhanced IMS's ability to measure analytes at higher concentrations. Taking N-methyl-2-pyrrolidone (NMP) as an example, this new sampling method expanded the dynamic range from 1 ppm to 200 ppm. The working principle and measurement strategy of this sampling method were also discussed, providing new insights for the design and application of IMS-based instruments.

18.
Sensors (Basel) ; 24(10)2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38794013

RESUMO

In many areas of engineering, the design of a new system usually involves estimating performance-related parameters from early stages of the project to determine whether a given solution will be compliant with the defined requirements. This aspect is particularly relevant during the design of satellite payloads, where the target environment is not easily accessible in most cases. In the context of Earth observation sensors, this problem has been typically solved with the help of a set of complex pseudo-empirical models and/or expensive laboratory equipment. This paper describes a more practical approach: the illumination conditions measured by an in-orbit payload are recreated on ground with the help of a replica of the same payload so the performance of another Earth observation sensor in development can be evaluated. The proposed method is specially relevant in the context of small satellites, as the possibility of having extra units devoted to these tasks becomes greater as costs are reduced. The results obtained using this method in an actual space mission are presented in this paper, giving valuable information that will help in further stages of the project.

19.
Sensors (Basel) ; 24(10)2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38794036

RESUMO

This paper reports on the testing and evaluation of a passive autoranging (AR) method designed to dynamically extend the measurement range of a photonic current transducer (PCT) to pave the way toward a realization of a combined metering- and protection-class current sensor. The PCT utilizes a current transformer (CT), a piezoelectric transducer (PZT), and a fiber Bragg grating (FBG) to enable current measurement at multiple points in an electrical power network whereby multiple sensors are deployed and interrogated serially using a single optical fiber. The autoranging technique relies on incorporating static MOSFET switches to instantaneously short individual serially connected CT burdens in response to a measured current magnitude exceeding pre-set thresholds. The AR circuit switching events produce distinctive signal features that are used by the proposed switching algorithm to apply appropriate scaling factors to reconstruct the measured current from the optical signal. It is shown through laboratory experiments that the AR circuit correctly reacts to pre-set burden current thresholds of 130% of the nominal value and 22 times the nominal value, signifying its "metering" and "protection" range boundaries. The circuit reaction time is below 4 ms, rendering it suitable for standard power system protection purposes. Moreover, the operation of the AR circuit is demonstrated for burden currents of up to 100 A for over 1 s, satisfying a test procedure for the secondary CT circuit, as required by some power system operators. It is demonstrated that the proposed switching algorithm allows for a correct reconstruction of the burden currents from the optical signal acquired by the FBG interrogator, offering the potential to realize a dual-class optical current sensor.

20.
ACS Nano ; 18(20): 12760-12770, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38728257

RESUMO

Phototransistors are light-sensitive devices featuring a high dynamic range, low-light detection, and mechanisms to adapt to different ambient light conditions. These features are of interest for bioinspired applications such as artificial and restored vision. In this work, we report on a graphene-based phototransistor exploiting the photogating effect that features picowatt- to microwatt-level photodetection, a dynamic range covering six orders of magnitude from 7 to 107 lux, and a responsivity of up to 4.7 × 103 A/W. The proposed device offers the highest dynamic range and lowest optical power detected compared to the state of the art in interfacial photogating and further operates air stably. These results have been achieved by a combination of multiple developments. For example, by optimizing the geometry of our devices with respect to the graphene channel aspect ratio and by introducing a semitransparent top-gate electrode, we report a factor 20-30 improvement in responsivity over unoptimized reference devices. Furthermore, we use a built-in dynamic range compression based on a partial logarithmic optical power dependence in combination with control of responsivity. These features enable adaptation to changing lighting conditions and support high dynamic range operation, similar to what is known in human visual perception. The enhanced performance of our devices therefore holds potential for bioinspired applications, such as retinal implants.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA