Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Acta Neurochir (Wien) ; 166(1): 328, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39107666

RESUMO

PURPOSE: In the absence of an intraoperative CT or MRI setup, post-implantation confirmation of electrode position in deep brain stimulation (DBS) requires patient transportation to the radiology unit, prolonging surgery time. This project aims to validate intraoperative 3D fluoroscopy (3DF), a widely available tool in Neurosurgical units, as a method to determine final electrode position. METHODS: We performed a retrospective study including 64 patients (124 electrodes) who underwent DBS at our institution. Intraoperative 3DF after electrode implantation and postoperative volumetric CT were acquired. The Euclidean coordinates of the electrode tip displayed in both imaging modalities were determined and inter-method deviations were assessed. Pneumocephalus was quantified and its potential impact in determining the electrode position analyzed. Finally, 3DF and CT-imposed exposure to radiation was compared. RESULTS: The difference between the electrode tip estimated by 3DF and CT was 0.85 ± 0.03 mm, and not significantly different (p = 0.11 for the distance to MCP assessed by both methods), but was, instead, highly correlated (p = 0.91; p < 0.0001). Even though pneumocephalus was larger in 3DF (6.89 ± 1.76 vs 5.18 ± 1.37 mm3 in the CT group, p < 0.001), it was not correlated with the difference in electrode position measured by both techniques (p = 0.17; p = 0.06). Radiation exposure from 3DF is significantly lower than CT (0.36 ± 0.03 vs 2.08 ± 0.05 mSv; p < 0.0001). CONCLUSIONS: Intraoperative 3DF is comparable to CT in determining the final DBS electrode position. Being a method with fewer radiation exposure, less expensive, faster and that avoids patient transportation outside the operation room, it is a valid tool to replace postoperative CT.


Assuntos
Estimulação Encefálica Profunda , Eletrodos Implantados , Imageamento Tridimensional , Humanos , Estimulação Encefálica Profunda/métodos , Fluoroscopia/métodos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto
2.
Trends Hear ; 28: 23312165241248973, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38717441

RESUMO

To preserve residual hearing during cochlear implant (CI) surgery it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring). A promising method is electrocochleography (ECochG). Within this project the relations between intracochlear ECochG recordings, position of the recording contact in the cochlea with respect to anatomy and frequency and preservation of residual hearing were investigated. The aim was to better understand the changes in ECochG signals and whether these are due to the electrode position in the cochlea or to trauma generated during insertion. During and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed using the CI electrode (MED-EL). During insertion, the recordings were performed at discrete insertion steps on electrode contact 1. After insertion as well as postoperatively the recordings were performed at different electrode contacts. The electrode location in the cochlea during insertion was estimated by mathematical models using preoperative clinical imaging, the postoperative location was measured using postoperative clinical imaging. The recordings were analyzed from six adult CI recipients. In the four patients with good residual hearing in the low frequencies the signal amplitude rose with largest amplitudes being recorded closest to the generators of the stimulation frequency, while in both cases with severe pantonal hearing losses the amplitude initially rose and then dropped. This might be due to various reasons as discussed in the following. Our results indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.


Assuntos
Audiometria de Resposta Evocada , Cóclea , Implante Coclear , Implantes Cocleares , Humanos , Cóclea/cirurgia , Cóclea/fisiologia , Cóclea/fisiopatologia , Implante Coclear/instrumentação , Implante Coclear/métodos , Audiometria de Resposta Evocada/métodos , Pessoa de Meia-Idade , Idoso , Masculino , Feminino , Audição/fisiologia , Adulto , Resultado do Tratamento , Valor Preditivo dos Testes , Estimulação Elétrica , Pessoas com Deficiência Auditiva/reabilitação , Pessoas com Deficiência Auditiva/psicologia , Limiar Auditivo/fisiologia
3.
Heliyon ; 9(2): e12467, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36852047

RESUMO

Temporal modulation sensitivity has been studied extensively for cochlear implant (CI) users due to its strong correlation to speech recognition outcomes. Previous studies reported that temporal modulation detection thresholds (MDTs) vary across the tonotopic axis and attributed this variation to patchy neural survival. However, correlates of neural health identified in animal models depend on electrode position in humans. Nonetheless, the relationship between MDT and electrode location has not been explored. We tested 13 ears for the effect of distance on modulation sensitivity, specifically targeting the question of whether electrodes closer to the modiolus are universally beneficial. Participants in this study were postlingually deafened and users of Cochlear Nucleus CIs. The distance of each electrode from the medial wall (MW) of the cochlea and mid-modiolar axis (MMA) was measured from scans obtained using computerized tomography (CT) imaging. The distance measures were correlated with slopes of spatial tuning curves measured on selected electrodes to investigate if electrode position accounts, at least in part, for the width of neural excitation. In accordance with previous findings, electrode position explained 24% of the variance in slopes of the spatial tuning curves. All functioning electrodes were also measured for MDTs. Five ears showed a positive correlation between MDTs and at least one distance measure across the array; 6 ears showed negative correlations and the remaining two ears showed no relationship. The ears showing positive MDT-distance correlations, thus benefiting from electrodes being close to the neural elements, were those who performed better on the two speech recognition measures, i.e., speech reception thresholds (SRTs) and recognition of the AzBio sentences. These results could suggest that ears able to take advantage of the proximal placement of electrodes are likely to have better speech recognition outcomes. Previous histological studies of humans demonstrated that speech recognition is correlated with spiral ganglion cell counts. Alternatively, ears with good speech recognition outcomes may have good overall neural health, which is a precondition for close electrodes to produce spatially confined neural excitation patterns that facilitate modulation sensitivity. These findings suggest that the methods to reduce channel interaction, e.g., perimodiolar electrode array or current focusing, may only be beneficial for a subgroup of CI users. Additionally, it suggests that estimating neural survival preoperatively is important for choosing the most appropriate electrode array type (perimodiolar vs. lateral wall) for optimal implant function.

4.
Artigo em Chinês | MEDLINE | ID: mdl-34628843

RESUMO

Cochlear implantation has become the primary treatment of choice for the patients with severe or profound sensorineural hearing loss. However, the outcomes of cochlear implantation are affected by many factors which need multi-disciplinary evaluation such as imaging, audiology and linguistics. Cone beam computed tomography, a novel imaging technique, has been increasingly used in the study of cochlear morphology, accurate location of electrode and evaluation of inner ear trauma after cochlear implantation. The aim of this review is to describe the advantages and application prospects of cone beam computed tomography, which is meaningful for the wider application of cone beam computed tomography in cochlear implantation.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Cóclea/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Perda Auditiva Neurossensorial/diagnóstico por imagem , Perda Auditiva Neurossensorial/cirurgia , Humanos
5.
Front Hum Neurosci ; 15: 631778, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33679351

RESUMO

Subthalamic nucleus (STN) deep brain stimulation (DBS) is an established therapy for Parkinson's disease motor symptoms. The ideal site for implantation within STN, however, remains controversial. While many argue that placement of a DBS lead within the sensorimotor territory of the STN yields better motor outcomes, others report similar effects with leads placed in the associative or motor territory of the STN, while still others assert that placing a DBS lead "anywhere within a 6-mm-diameter cylinder centered at the presumed middle of the STN (based on stereotactic atlas coordinates) produces similar clinical efficacy." These discrepancies likely result from methodological differences including targeting preferences, imaging acquisition and the use of brain atlases that do not account for patient-specific anatomic variability. We present a first-in-kind within-patient demonstration of severe mood side effects and minimal motor improvement in a Parkinson's disease patient following placement of a DBS lead in the limbic/associative territory of the STN who experienced marked improvement in motor benefit and resolution of mood side effects following repositioning the lead within the STN sensorimotor territory. 7 Tesla (7 T) magnetic resonance imaging (MRI) data were used to generate a patient-specific anatomical model of the STN with parcellation into distinct functional territories and computational modeling to assess the relative degree of activation of motor, associative and limbic territories.

6.
Z Med Phys ; 31(3): 265-275, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32620321

RESUMO

INTRODUCTION: Despite using the soft-surgery technique, cochlear implantation may increase the damage of the intracochlear structures due to a scalar translocation of the electrode. The aim of this work was to investigate the incidence as well as the audiological and electrophysiological outcome for electrode translocations and complete scala tympani insertions of perimodiolar electrodes within a large group of patients. MATERIAL AND METHODS: The investigations were performed retrospectively on 255 adult subjects with a Nucleus Contour Advance or Slim Modiolar electrode (Cochlear Ltd.). The scalar position was assessed by postoperative rotational tomography. Intraoperative and one year after CI activation measured ECAP thresholds were examined as well as the postoperative speech recognition in quiet using the Freiburg monosyllable word test. RESULTS: The incidence of a translocation was significantly lower with the Slim Modiolar than with the Contour Advance electrode (5.1% versus 32.3%; p<0.05). With a scala tympani placement the median speech recognition score was 75% (range: 20- 100%) with the Contour Advance and 72.5% (range: 27.5-95%) with the Slim Modiolar electrode. In cases with an electrode translocation, speech recognition scores show a median of 75% (range: 45-100%) and 73.8% (range: 40-80%), respectively. No significant differences in speech recognition were found between translocations and scala tympani insertions with both electrodes. Compared to scala tympani insertions, electrode translocations yielded higher ECAP thresholds at apical and medial electrode contacts (p<0.05). CONCLUSION: The incidence of an electrode translocation is determined for both perimodiolar electrode types analyzed in this work. ECAP measurements provide additional information for detecting translocations compared to radiological imaging. However, the postoperative speech recognition in quiet was not affected by the scalar position in the electrodes examined here.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Eletrodos Implantados , Humanos , Estudos Retrospectivos , Rampa do Tímpano/cirurgia
7.
Sensors (Basel) ; 19(20)2019 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-31615163

RESUMO

Body surface potential mapping (BSPM) is a valuable tool for research regarding electrocardiograms (ECG). However, the BSPM system is limited by its large number of electrodes and wires, long installation time, and high computational complexity. In this paper, we designed a wearable four-electrode electrocardiogram-sensor (WFEES) module that measures six-channel ECGs simultaneously for ECG investigation. To reduce the testing lead number and the measurement complexity, we further proposed a method, the layered (A, N) square-based (LANS) method, to optimize the ECG acquisition and analysis process using WFEES modules for different applications. Moreover, we presented a case study of electrode location optimization for wearable single-lead ECG monitoring devices using WFEES modules with the LANS method. In this study, 102 sets of single-lead ECG data from 19 healthy subjects were analyzed. The signal-to-noise ratio of ECG, as well as the mean and coefficient of variation of QRS amplitude, was derived among different channels to determine the optimal electrode locations. The results showed that a single-lead electrode pair should be placed on the left chest above the electrode location of standard precordial leads V1 to V4. Additionally, the best orientation was the principal diagonal as the direction of the heart's electrical axis.


Assuntos
Algoritmos , Eletrocardiografia , Dispositivos Eletrônicos Vestíveis , Adulto , Mapeamento Potencial de Superfície Corporal , Eletrodos , Feminino , Humanos , Masculino , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
8.
Parkinsonism Relat Disord ; 66: 110-116, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31327627

RESUMO

BACKGROUND: Speech disorders, including stuttering and hypophonia, have been reported in patients with Parkinson's disease (PD) after subthalamic deep brain stimulation (STN-DBS). OBJECTIVE: To evaluate the effect of stimulation frequency or electrode contact location on speech disorders in PD patients with STN-DBS. METHOD: In this case-controlled study, we enrolled 50 PD patients with, and 100 PD patients without STN-DBS to compare their vocal intensities, measured by a sound pressure meter, and perceptual speech ratings, obtained from the speech sections of the United Parkinson's Disease Rating Scale (UPDRS) and subjective ratings regarding the impediment of functional communication by stuttering. For patients with STN-DBS, comparisons were made between high-frequency (HFS; 130 Hz), low-frequency (LFS; 80 Hz), and off-stimulation. We also evaluated the effect of electrode contact locations on speech function. RESULTS: Patients with STN-DBS had decreased vocal intensities and UPDRS scores compared to those without (p < 0.05). Vocal intensity was significantly lower during HFS than during LFS and off-stimulation (both, p < 0.05). Stuttering impeded STN-DBS patients' communication to greater extent than for those without (p < 0.001). Vocal intensity was lower when active contacts were in the dorsal zone compared to those in the ventral zone (p < 0.05). Only STN-DBS treatment was a predictive factor for low vocal intensity (OR = 9.53, p = 0.04). CONCLUSION: High-frequency STN-DBS with dorsal zone contacts can aggravate certain speech problems in PD patients. Therefore, it is important to balance between motor control and speech impairments in these patients.


Assuntos
Estimulação Encefálica Profunda/efeitos adversos , Estimulação Encefálica Profunda/métodos , Doença de Parkinson/complicações , Doença de Parkinson/terapia , Distúrbios da Fala/etiologia , Idoso , Eletrodos Implantados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Núcleo Subtalâmico/fisiopatologia
9.
World Neurosurg X ; 3: 100024, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31225518

RESUMO

BACKGROUND: Deep brain stimulation of the motor thalamus or the posterior subthalamic area (PSA) shows promising results for patients with voice tremor, although only for about 50% of patients. There are indications that voice tremor requires more focused stimulation within the target area compared with hand tremor. The objective of the present study was to determine the most efficient location for reducing voice tremor within the PSA. METHODS: Thirty-seven patients with essential tremor were evaluated off stimulation and in a set of experimental conditions with unilateral stimulation at increasing amplitude levels. Two listeners performed blinded assessments of voice tremor from recordings of sustained vowel productions. RESULTS: Twenty-five patients (68%) had voice tremor. Unilateral stimulation reduced voice tremor for the majority of patients, and only 6 patients had poor outcomes. Contacts yielding efficient voice tremor reduction were deeper relative to the midcommissural point (MCP) and more posterior relative to the posterior tip of the subthalamic nucleus (pSTN) (zMCP = -3.1, ypSTN = -0.2) compared with poor contacts (zMCP = -0.7, ypSTN = 1.0). High-amplitude stimulation worsened voice tremor for 7 patients and induced voice tremor in 2 patients. Hand tremor improved to a greater extent than voice tremor, and improvements could be seen throughout the target area. CONCLUSIONS: Our results indicate that efficient voice tremor reduction can be achieved by stimulating contacts located in the inferior part of the PSA, close or slightly posterior to the pSTN. We observed cases in which voice tremor was induced by high-amplitude stimulation.

10.
Front Physiol ; 9: 404, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29867517

RESUMO

Introduction: Focal atrial tachycardia is commonly treated by radio frequency ablation with an acceptable long-term success. Although the location of ectopic foci tends to appear in specific hot-spots, they can be located virtually in any atrial region. Multi-electrode surface ECG systems allow acquiring dense body surface potential maps (BSPM) for non-invasive therapy planning of cardiac arrhythmia. However, the activation of the atria could be affected by fibrosis and therefore biomarkers based on BSPM need to take these effects into account. We aim to analyze the effect of fibrosis on a BSPM derived index, and its potential application to predict the location of ectopic foci in the atria. Methodology: We have developed a 3D atrial model that includes 5 distributions of patchy fibrosis in the left atrium at 5 different stages. Each stage corresponds to a different amount of fibrosis that ranges from 2 to 40%. The 25 resulting 3D models were used for simulation of Focal Atrial Tachycardia (FAT), triggered from 19 different locations described in clinical studies. BSPM were obtained for all simulations, and the body surface potential integral maps (BSPiM) were calculated to describe atrial activations. A machine learning (ML) pipeline using a supervised learning model and support vector machine was developed to learn the BSPM patterns of each of the 475 activation sequences and relate them to the origin of the FAT source. Results: Activation maps for stages with more than 15% of fibrosis were greatly affected, producing conduction blocks and delays in propagation. BSPiMs did not always cluster into non-overlapped groups since BSPiMs were highly altered by the conduction blocks. From stage 3 (15% fibrosis) the BSPiMs showed differences for ectopic beats placed around the area of the pulmonary veins. Classification results were mostly above 84% for all the configurations studied when a large enough number of electrodes were used to map the torso. However, the presence of fibrosis increases the area of the ectopic focus location and therefore decreases the utility for the electrophysiologist. Conclusions: The results indicate that the proposed ML pipeline is a promising methodology for non-invasive ectopic foci localization from BSPM signal even when fibrosis is present.

11.
BMC Res Notes ; 10(1): 300, 2017 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-28728611

RESUMO

OBJECTIVE: The present study aimed to test the effect of the electrode position and inter-electrode distance on the evoked force by neuromuscular electrical stimulation (NMES) with a low current intensity and a single pair of electrodes. Knee extensor forces during NMES to quadriceps femoris muscles were compared among four different electrode configurations in seven healthy men. Electrodes were located at 10 cm proximal and 15 cm distal (P10-D15), 10 cm proximal and 10 cm distal (P10-D10), 5 cm proximal and 15 cm distal, and 5 cm proximal and 10 cm distal (P5-D10) to the center of the longitudinal axis of the quadriceps femoris muscles. RESULTS: The evoked force-time area for P5-D10 was significantly higher than those for P10-D15 and P10-D10 (p < 0.05). When using NMES devices with a low current intensity, a shorter inter-electrode distance and relatively distal locations can promote greater evoked forces in the quadriceps femoris muscles.


Assuntos
Estimulação Elétrica/métodos , Eletrodos , Músculo Quadríceps/fisiologia , Adulto , Humanos , Masculino , Músculo Quadríceps/inervação , Adulto Jovem
12.
Laryngoscope ; 127(10): 2352-2357, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28304096

RESUMO

OBJECTIVES: 1) Examine angular insertion depths (AID) and scalar location of Med-El (GmbH Innsbruck, Austria) electrodes; and 2) determine the relationship between AID and audiologic outcomes controlling for scalar position. STUDY DESIGN: Retrospective review. METHODS: Postlingually deafened adults undergoing cochlear implantation with Flex 24, Flex 28, and Standard electrode arrays (Med-El) were identified. Patients with preoperative and postoperative computed tomography scans were included so that electrode location and AID could be determined. Outcome measures were 1) speech perception in the cochlear implant (CI)-only condition, and 2) short-term hearing preservation. RESULTS: Forty-eight implants were included; all electrodes (48 of 48) were positioned entirely within the scala tympani. The median AID was 408° (interquartile [IQ] range 373°-449°) for Flex 24, 575° (IQ range 465°-584°) for Flex 28, and 584° (IQ range 368°-643°) for Standard electrodes (Med-El). The mean postoperative CNC score was 43.7% ± 21.9. A positive correlation was observed between greater AID and better CNC performance (r = 0.48, P < 0.001). Excluding patients with postoperative residual hearing, a strong correlation between AID and CNC persisted (r = 0.57, P < 0.001). In patients with preoperative residual hearing, mean low-frequency pure-tone average (PTA) shift was 27 dB ± 14. A correlation between AID and low-frequency PTA shift at activation was noted (r = 0.41, P = 0.04). CONCLUSION: Favorable rates of scala tympani insertion (100%) were observed. In the CI-only condition, a direct correlation between greater AID and CNC score was noted regardless of postoperative hearing status. Deeper insertions were, however, associated with worse short-term hearing preservation. When patients without postoperative residual hearing were analyzed independently, the relationship between greater insertion depth and better performance was strengthened. LEVEL OF EVIDENCE: 4. Laryngoscope, 127:2352-2357, 2017.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Perda Auditiva Unilateral/reabilitação , Audição/fisiologia , Rampa do Tímpano/cirurgia , Percepção da Fala/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Perda Auditiva Unilateral/fisiopatologia , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Rampa do Tímpano/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento
13.
J Neurosci Methods ; 278: 36-45, 2017 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-28017737

RESUMO

BACKGROUND: The growing popularity of simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) opens up the possibility of imaging EEG electrodes while the subject is in the scanner. Such information could be useful for improving the fusion of EEG-fMRI datasets. NEW METHOD: Here, we report for the first time how an ultra-short echo time (UTE) MR sequence can image the materials of an MR-compatible EEG cap, finding that electrodes and some parts of the wiring are visible in a high resolution UTE. Using these images, we developed a segmentation procedure to obtain electrode coordinates based on voxel intensity from the raw UTE, using hand labeled coordinates as the starting point. RESULTS: We were able to visualize and segment 95% of EEG electrodes using a short (3.5min) UTE sequence. We provide scripts and template images so this approach can now be easily implemented to obtain precise, subject-specific EEG electrode positions while adding minimal acquisition time to the simultaneous EEG-fMRI protocol. COMPARISON WITH EXISTING METHOD(S): T1 gel artifacts are not robust enough to localize all electrodes across subjects, the polymers composing Brainvision cap electrodes are not visible on a T1, and adding T1 visible materials to the EEG cap is not always possible. We therefore consider our method superior to existing methods for obtaining electrode positions in the scanner, as it is hardware free and should work on a wide range of materials (caps). CONCLUSIONS: EEG electrode positions are obtained with high precision and no additional hardware.


Assuntos
Eletrodos , Eletroencefalografia/instrumentação , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Polímeros , Adulto , Artefatos , Eletroencefalografia/métodos , Feminino , Humanos , Masculino , Imagem Multimodal/instrumentação , Fatores de Tempo , Adulto Jovem
14.
Laryngoscope Investig Otolaryngol ; 1(6): 169-174, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-28894813

RESUMO

OBJECTIVES: As indications for cochlear implantation have expanded to include patients with more residual hearing, increasing emphasis has been placed on minimally traumatic electrode insertion. Histopathologic evaluation remains the gold standard for evaluation of cochlear trauma, but advances in imaging techniques have allowed clinicians to determine scalar electrode location in vivo. This review will examine the relationship between scalar location of electrode arrays and audiologic outcomes. In addition, the impact that surgical approach, electrode design, and insertion depth have on scalar location will be evaluated. Data Sources: PubMed literature review Review Methods: A review of the current literature was conducted to analyze the relationship between scalar location of cochlear implant electrode arrays and speech perception outcomes. Further, data were reviewed to determine the impact that surgical variables have on scalar electrode location. RESULTS: Electrode insertions into the scala tympani are associated with superior speech perception and higher rates of hearing preservation. Lateral wall electrodes, and round window/extended round window approaches appear to maximize the likelihood of a scala tympani insertion. It does not appear that deeper insertions are associated with higher rates of scalar translocation. CONCLUSION: Superior audiologic outcomes are observed for electrode arrays inserted entirely within the scala tympani. The majority of clinical data demonstrate that lateral wall design and a round window approach increase the likelihood of a scala tympani insertion. LEVEL OF EVIDENCE: N/A.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA