Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 913
Filtrar
1.
Comput Biol Med ; 181: 109063, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39178807

RESUMO

Investigating and understanding the biomechanical kinematics and kinetics of human brain axonal fibers during head impact process is crucial to study the mechanisms of Traumatic Axonal Injury (TAI). Such a study may require the explicit incorporation of brain fiber tracts into the host brain in order to distinguish the mechanical states of axonal fibers and brain tissue. Herein we extend our previously developed human head model by using an embedded element method to include fiber tracts reconstructed from diffusion tensor images in a host brain with the purpose of numerically tracking the deformation state of axonal fiber tracts during a head impact simulation. The updated model is validated by comparing its prediction of intracranial pressures with experimental data, followed by a thorough study of the effects of element types used for fiber tracts and the stiffness ratios of fiber to host brain. The validated model is also used to predict and visualize the damaged region of fiber tracts during the head impact process based on different injury criteria. The model is promising in tracking the state of fiber tracts and can add more objective functions such as axonal fiber deformation if used in the future design optimization of head protective equipment such as a football helmet.

2.
Bioinspir Biomim ; 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39178899

RESUMO

Like other odontocetes, Risso's dolphins actively emit clicks and passively listen to the echoes during echolocation. However, the head anatomy of Risso's dolphins differs from that of other odontocetes by a unique vertical cleft along the anterior surface of the forehead and a differently-shaped lower jaw. In this study, 3D finite-element sound reception and production models were constructed based on CT data of a deceased Risso's dolphin. Our results were verified by finding good agreement with experimental measurements of hearing sensitivity. Moreover, the acoustic pathway for sounds to travel from the seawater into the dolphin's tympanoperiotic complexes (TPCs) was computed. The gular reception mechanism, previously discovered in Delphinus delphis and Ziphius cavirostris, was also found in this species. The received sound pressure levels and relative displacement at TPC surfaces were compared between the cases with and without the mandibular fats or mandible. The results demonstrate a pronounced wave-guiding role of the mandibular fats and a limited bone-conductor role of the mandible. For sound production modelling, we digitally filled the cleft with neighbouring soft tissues, creating a hypothetical "cleftless" head. Comparison between sound travelling through a "cleftless" head vs. an original head indicates that the distinctive cleft plays a limited role in biosonar sound propagation.

3.
Polymers (Basel) ; 16(15)2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39125125

RESUMO

Polymer composite materials are increasingly used in civil aircraft structures. The failure mode and energy-absorption characteristics of polymer composite structures have garnered significant attention from academia and industry. For thin-walled polymer composite C-channels with layups of [0/90]3s, [45/-45]3s, and [45/90/-45/0]3, low-speed axial compression tests were performed to investigate the failure modes, failure mechanisms, and energy-absorbing characteristics. After parametric studies using [0] and [90] single-element models, stacked shell models of thin-walled composite C-channels were established using the Lavadèze single-layer damage constitutive model, Puck 2000, and Yamada Sun failure criteria. The results show that these thin-walled composite C-channels exhibit a stable progressive crushing process with a local buckling failure mode, encompassing local buckling, fiber break-age, matrix cracks, delamination, and corner cracking. The stacked shell model demonstrates reasonable agreement with the progressive crushing process of thin-walled composites, accurately capturing interlayer matrix failure and interface delamination cracking behavior. A comparison of the specific energy absorption (SEA) and mean crushing force (Fmean) between the simulation and test results yields a difference of less than 6%, indicating a strong correlation between the simulation results and the experimental energy-absorbing characteristics. It also shows that a deep understanding of the parameters is helpful for accurate numerical modeling.

4.
J Mech Behav Biomed Mater ; 159: 106679, 2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-39180890

RESUMO

Implant subsidence into the underlying trabecular bone is a common problem in orthopaedic surgeries; however, the ability to pre-operatively predict implant subsidence remains limited. Current state-of-the-art computational models for predicting subsidence have issues addressing this clinical problem, often resulting from the size and complexity of existing subject-specific, image-based finite element (FE) models. The current study aimed to develop a simplified approach to FE modeling of subject-specific trabecular bone indentation resulting from implant penetration. Confined indentation experiments of human trabecular bone with flat- and sharp-tip indenters were simulated using FE analysis. A generalized continuum-level approach using a meshless smoothed particle hydrodynamics (SPH) approach and an isotropic crushable foam (CF) material model was developed for the trabecular bone specimens. Five FE models were generated with CF material parameters calibrated to cadaveric specimens spanning a range of bone mineral densities (BMD). Additionally, an alternative model configuration was developed that included consideration of bone marrow, with bone and marrow material parameters assigned to elements randomly according to bone volume (BV%) measurements of experimental specimens, owing to the non-uniform nature of trabecular bone tissue microstructure. Statistical analysis found significant correlation between the shapes of the numerical and experimental force-displacement curves. FE models accurately captured the bone densification patterns observed experimentally. Inclusion of marrow elements offered improved response prediction of the flat-tip indenter tests. Ultimately, the developed approach demonstrates the ability of a generalizable continuum-level SPH approach to capture bone variability using clinical bone imaging metrics without needing detailed image-based geometries, a significant step towards simplified subject-specific modeling of implant subsidence.

5.
J Mech Behav Biomed Mater ; 159: 106685, 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39173497

RESUMO

Micro-scale models of lung tissue have been employed by researchers to investigate alveolar mechanics; however, they have been limited by the lack of biofidelic material properties for the alveolar wall. To address this challenge, a finite element model of an alveolar cluster was developed comprising a tetrakaidecahedron array with the nominal characteristics of human alveolar structure. Lung expansion was simulated in the model by prescribing a pressure and monitoring the volume, to produce a pressure-volume (PV) response that could be compared to experimental PV data. The alveolar wall properties in the model were optimized to match experimental PV response of lungs filled with saline, to eliminate surface tension effects and isolate the alveolar wall tissue response. When simulated in uniaxial tension, the model was in agreement with reported experimental properties of uniaxial tension on excised lung tissue. The work presented herein was able to link micro-scale alveolar response to two disparate macroscopic experimental datasets (stress-stretch and PV response of lung) and presents hyperelastic properties of the alveolar wall for use in alveolar scale finite element models and multi-scale models. Future research will incorporate surface tension effects, and investigate alveolar injury mechanisms.

6.
Ann Biomed Eng ; 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39120770

RESUMO

The risk of aseptic loosening in cementless hip stems can be reduced by improving osseointegration with osteoinductive coatings favoring long-term implant stability. Osseointegration is usually evaluated in vivo studies, which, however, do not reproduce the mechanically driven adaptation process. This study aims to develop an in silico model to predict implant osseointegration and the effect of induced micromotion on long-term stability, including a calibration of the material osteoinductivity with conventional in vivo studies. A Finite Element model of the tibia implanted with pins was generated, exploiting bone-to-implant contact measures of cylindrical titanium alloys implanted in rabbits' tibiae. The evolution of the contact status between bone and implant was modeled using a finite state machine, which updated the contact state at each iteration based on relative micromotion, shear and tensile stresses, and bone-to-implant distance. The model was calibrated with in vivo data by identifying the maximum bridgeable gap. Afterward, a push-out test was simulated to predict the axial load that caused the macroscopic mobilization of the pin. The bone-implant bridgeable gap ranged between 50 µm and 80 µm. Predicted push-out strength ranged from 19 N to 21 N (5.4 MPa-3.4 MPa) depending on final bone-to-implant contact. Push-out strength agrees with experimental measurements from a previous animal study (4 ± 1 MPa), carried out using the same implant material, coated, or uncoated. This method can partially replace in vivo studies and predict the long-term stability of cementless hip stems.

7.
Front Bioeng Biotechnol ; 12: 1399691, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39015138

RESUMO

Introduction: Surgical correction is a common treatment for severe scoliosis. Due to the significant spinal deformation that occurs with this condition, spinal cord injuries during corrective surgery can occur, sometimes leading to paralysis. Methods: Such events are associated with biomechanical changes in the spinal cord during surgery, however, their underlying mechanisms are not well understood. Six patient-specific cases of scoliosis either with or without spinal complications were examined. Finite element analyses (FEA) were performed to assess the dynamic changes and stress distribution of spinal cords after surgical correction. The FEA method is a numerical technique that simplifies problem solving by replacing complex problem solving with simplified numerical computations. Results: In four patients with poor prognosis, there was a concentration of stress in the spinal cord. The predicted spinal cord injury areas in this study were consistent with the clinical manifestations of the patients. In two patients with good prognosis, the stress distribution in the spinal cord models was uniform, and they showed no abnormal clinical manifestations postoperatively. Discussion: This study identified a potential biomechanical mechanism of spinal cord injury caused by surgical correction of scoliosis. Numerical prediction of postoperative spinal cord stress distribution might improve surgical planning and avoid complications.

8.
Artigo em Inglês | MEDLINE | ID: mdl-39003653

RESUMO

Spinal cord stress and strain contribute to degenerative cervical myelopathy (DCM), while cervical kyphosis is known to negatively impact surgical outcomes. In DCM, the relationship between spinal cord biomechanics, sagittal alignment, and cord compression is not well understood. Quantifying this relationship can guide surgical strategies. A previously validated three-dimensional finite element model of the human cervical spine with spinal cord was used. Three models of cervical alignment were created: lordosis (C2-C7 Cobb angle: 20°), straight (0°), and kyphosis (- 9°). C5-C6 spinal stenosis was simulated with ventral disk protrusions, reducing spinal canal diameters to 10 mm, 8 mm, and 6 mm. Spinal cord pre-stress and pre-strain due to alignment and compression were quantified. Cervical flexion and extension were simulated with a pure moment load of 2 Nm. The Von Mises stress and maximum principal strain of the whole spinal cord were calculated during neck motion and the relationship between spinal cord biomechanics, alignment, and compression was analyzed using linear regression analysis. Spinal cord pre-stress and pre-strain were greatest with kyphosis (7.53 kPa, 5.4%). Progressive kyphosis and stenosis were associated with an increase in spinal cord stress (R2 = 0.99) and strain (R2 = 0.99). Cervical kyphosis was associated with greater spinal cord stress and strain during neck flexion-extension and the magnitude of difference increased with increasing stenosis. Cervical kyphosis increases baseline spinal cord stress and strain. Incorporating sagittal alignment with compression to calculate spinal cord biomechanics is necessary to accurately quantify spinal stress and strain during neck flexion and extension.

9.
Front Bioeng Biotechnol ; 12: 1387768, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39040495

RESUMO

Background: The plantar vault, comprising the transverse and longitudinal arches of the human foot, is essential for impact absorption, elastic energy storage, and propulsion. Recent research underscores the importance of the transverse arch, contributing over 40% to midfoot stiffness. This study aimed to quantify biomechanical responses in the ankle-foot complex by varying the stiffness of the deep metatarsal transverse ligament (DTML). Methods: Using CT image reconstruction, we constructed a complex three-dimensional finite element model of the foot and ankle joint complex, accounting for geometric complexity and nonlinear characteristics. The focus of our study was to evaluate the effect of different forefoot transverse arch stiffness, that is, different Young's modulus values of DTML (from 135 MPa to 405 MPa), on different biomechanical aspects of the foot and ankle complex. Notably, we analyzed their effects on plantar pressure distribution, metatarsal stress patterns, navicular subsidence, and plantar fascial strain. Results: Increasing the stiffness of the DTML has significant effects on foot biomechanics. Specifically, higher DTML stiffness leads to elevate von Mises stress in the 1st, 2nd, and 3rd metatarsals, while concurrently reducing plantar pressure by 14.2% when the Young's modulus is doubled. This stiffening also impedes navicular bone subsidence and foot lengthening. Notably, a 100% increase in the Young's modulus of DTML results in a 54.1% decrease in scaphoid subsidence and a 2.5% decrease in foot lengthening, which collectively contribute to a 33.1% enhancement in foot longitudinal stiffness. Additionally, doubling the Young's modulus of DTML can reduce the strain stretch of the plantar fascia by 38.5%. Conclusion: Preserving DTML integrity sustains the transverse arch, enhancing foot longitudinal stiffness and elastic responsiveness. These findings have implications for treating arch dysfunction and provide insights for shoe developers seeking to enhance propulsion.

10.
Artigo em Inglês | MEDLINE | ID: mdl-39044037

RESUMO

PURPOSE: Adolescent idiopathic scoliosis is a chronic disease that may require correction surgery. The finite element method (FEM) is a popular option to plan the outcome of surgery on a patient-based model. However, it requires considerable computing power and time, which may discourage its use. Machine learning (ML) models can be a helpful surrogate to the FEM, providing accurate real-time responses. This work implements ML algorithms to estimate post-operative spinal shapes. METHODS: The algorithms are trained using features from 6400 simulations generated using the FEM from spine geometries of 64 patients. The features are selected using an autoencoder and principal component analysis. The accuracy of the results is evaluated by calculating the root-mean-squared error and the angle between the reference and predicted position of each vertebra. The processing times are also reported. RESULTS: A combination of principal component analysis for dimensionality reduction, followed by the linear regression model, generated accurate results in real-time, with an average position error of 3.75 mm and orientation angle error below 2.74 degrees in all main 3D axes, within 3 ms. The prediction time is considerably faster than simulations based on the FEM alone, which require seconds to minutes. CONCLUSION: It is possible to predict post-operative spinal shapes of patients with AIS in real-time by using ML algorithms as a surrogate to the FEM. Clinicians can compare the response of the initial spine shape of a patient with AIS to various target shapes, which can be modified interactively. These benefits can encourage clinicians to use software tools for surgical planning of scoliosis.

11.
Diagnostics (Basel) ; 14(14)2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39061634

RESUMO

Cervical laminoplasty is an established motion-preserving procedure for degenerative cervical myelopathy (DCM). However, patients with pre-existing cervical kyphosis often experience inferior outcomes compared to those with straight or lordotic spines. Limited dorsal spinal cord shift in kyphotic spines post-decompression and increased spinal cord tension may contribute to poor neurological recovery and spinal cord injury. This study aims to quantify the biomechanical impact of cervical sagittal alignment on spinal cord stress and strain post-laminoplasty using a validated 3D finite element model of the C2-T1 spine. Three models were created based on the C2-C7 Cobb angle: lordosis (20 degrees), straight (0 degrees), and kyphosis (-9 degrees). Open-door laminoplasty was simulated at C4, C5, and C6 levels, followed by physiological neck flexion and extension. The results showed that spinal cord stress and strain were highest in kyphotic curvature compared to straight and lordotic curvatures across all cervical segments, despite similar segmental ROM. In flexion, kyphotic spines exhibited 103.3% higher stress and 128.9% higher strain than lordotic spines and 16.7% higher stress and 26.8% higher strain than straight spines. In extension, kyphotic spines showed 135.4% higher stress and 241.7% higher strain than lordotic spines and 21.5% higher stress and 43.2% higher strain than straight spines. The study shows that cervical kyphosis leads to increased spinal cord stress and strain post-laminoplasty, underscoring the need to address sagittal alignment in addition to decompression for optimal patient outcomes.

12.
Materials (Basel) ; 17(13)2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38998379

RESUMO

Warm mix flame retardant asphalt mixture can reduce the energy dissipation and harmful gas emissions during asphalt pavement construction, as well as mitigate the adverse effects of road fires. For this, this paper studies the design and performance of a mixture modified with a combination of warm mix agent and flame retardant, and the pavement performance and flame retardancy of the modified mixture are evaluated. Additionally, a flame retardancy prediction model based on the radial basis function (RBF) neural network model is established. On this basis, the principal components analysis (PCA) model is used to analyze the most significant evaluation indicators affecting flame retardancy, and finally, a three-dimensional finite element model is developed to analyze the effects of loading on the pavement structure. The results show that compared to virgin asphalt mixture, the modified mixture shows a reduction in mixing and compaction temperatures by approximately 12 °C. The high-temperature performance of the mixture is improved, while the low-temperature performance and moisture stability slightly decrease, but its flame retardancy is significantly enhanced. The RBF neural network model revealed that the established flame retardancy prediction model has a high accuracy, allowing for precise evaluation of the flame retardancy. Finally, the PCA model identified that the combustion time has a significant effect on the flame retardancy of the asphalt mixture, and the finite element model revealed that the displacements of the warm mix fire retardant asphalt mixture were lower than virgin asphalt mixture in all directions under the loading.

13.
Sci Rep ; 14(1): 15889, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38987319

RESUMO

The study investigates the bending strength of tracks of box headers beyond AISI, which considers the capacity of individual channels alone. Both experimental and FEM are used, and the results are compared to AISI. The findings highlight tracks' significant role in the overall bending capacity. AISI is found to be conservative by 34% to 152%. Failure mode is different from code theoretical expectations for a single channel. Fastener close spacing marginally improves the capacity, while side fasteners offer significant enhancement, but track widening limits this enhancement. A modification to AISI is proposed considering track strength, with outcomes showing good accuracy.

14.
J Orthop Res ; 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-39031826

RESUMO

Obesity is a known risk factor for development of osteoarthritis (OA). Numerical tools like finite-element (FE) models combined with degenerative algorithms have been developed to understand the interplay between OA and obesity. In this study, we aimed to predict knee cartilage degeneration in a cohort of obese adults to investigate the importance of patient-specific information on degeneration predictions. We used a validated FE modeling approach and three different age-dependent functions (step-wise, exponential, and linear) to simulate cartilage degradation under overloading in the knee joint. Gait motion analysis and magnetic resonance imaging data from 115 obese individuals with knee OA were used for musculoskeletal and FE modeling. Cartilage degeneration predictions were contrasted with Kellgren-Lawrence (KL) and Boston-Leeds Osteoarthritis Knee Score (BLOKS) grades. The findings show that overall, the similarities between numerical predictions and clinical measures were better for the medial (average area under the curve (AUC) = 0.62) compared to the lateral compartment (average AUC = 0.52) of the knee. Classification results for KL grades, full patient-specific models and patient-specific geometry with generic gait data showed higher AUC values (AUC = 0.71 and AUC = 0.68, respectively) compared to generic geometry and patient-specific gait (AUC = 0.48). For BLOKS grades, AUC values for both full patient-specific models and for patient-specific geometry with generic gait locomotion were higher (AUC = 0.66 and AUC = 0.64, respectively) compared to when the generic geometry and patient-specific gait were used (AUC = 0.53). In summary, our study highlights the importance of considering individual information in knee OA prediction. Nevertheless, our findings suggest that personalized gait play a smaller role in the OA prediction and classification capacity than personalized joint geometry.

15.
J Neural Eng ; 21(4)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39029505

RESUMO

Objective. The cochlear implant (CI) belongs to the most successful neuro-prostheses. Traditionally, the stimulating electrode arrays are inserted into the scala tympani (ST), the lower cochlear cavity, which enables simple surgical access. However, often deep insertion is blocked, e.g. by ossification, and the auditory nerve fibers (ANFs) of lower frequency regions cannot be stimulated causing severe restrictions in speech understanding. As an alternative, the CI can be inserted into the scala vestibuli (SV), the other upper cochlear cavity.Approach. In this computational study, the excitability of 25 ANFs are compared for stimulation with ST and SV implants. We employed a 3-dimensional realistic human cochlear model with lateral wall electrodes based on aµ-CT dataset and manually traced fibers. A finite element approach in combination with a compartment model of a spiral ganglion cell was used to simulate monophasic stimulation with anodic (ANO) and cathodic (CAT) pulses of 50µs.Main results. ANO thresholds are lower in ST (mean/std =µ/σ= 189/55µA) stimulation compared to SV (µ/σ= 323/119µA) stimulation. Contrary, CAT thresholds are higher for the ST array (µ/σ= 165/42µA) compared to the SV array (µ/σ= 122/46µA). The threshold amplitude depends on the specific fiber-electrode spatial relationship, such as lateral distance from the cochlear axis, the angle between electrode and target ANF, and the curvature of the peripheral process. For CAT stimulation the SV electrodes show a higher selectivity leading to less cross-stimulation of additional fibers from different cochlear areas.Significance. We present a first simulation study with a human cochlear model that investigates an additional CI placement into the SV and its impact on the excitation behavior. Results predict comparable outcomes to ST electrodes which confirms that SV implantation might be an alternative for patients with a highly obstructed ST.


Assuntos
Implante Coclear , Implantes Cocleares , Nervo Coclear , Rampa do Tímpano , Rampa do Vestíbulo , Humanos , Nervo Coclear/fisiologia , Rampa do Tímpano/fisiologia , Rampa do Tímpano/cirurgia , Rampa do Vestíbulo/fisiologia , Implante Coclear/métodos , Implante Coclear/instrumentação , Eletrodos Implantados , Estimulação Elétrica/métodos , Estimulação Elétrica/instrumentação , Cóclea/fisiologia , Simulação por Computador
16.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 46(3): 341-347, 2024 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-38953258

RESUMO

Objective To demonstrate the feasibility of oblique lumbar interbody fusion (OLIF) combined with 4-screw fixation for treating two-level lumbar degenerative diseases.Methods An intact finite element model of L3-S1 (M0) was constructed and validated.Then,we constructed the M1 model by simulating OLIF surgery at L3/4 and L4/5 segments on the M0 model.By attachment of posterior 4-screw or 6-screw fixation to the M1 model,three 4-screw fixation models (M2-M4) and one 6-screw fixation model (M5) were established.The segmental and overall range of motion (ROM) and the peak von Mises stresses of superior endplate,cage,and posterior screw-rod were investigated under each implanted condition.Results Under the motion modes of forward flexion,backward extension,bilateral (left and right) flexion,and left and right rotation,the L3/4 ROM of M2 model and L4/5 ROM of M3 model increased,while the L3/4 and L4/5 ROM of M4 and M5 models significantly decreased compared with those of M1 model.Under all motion modes,the L4 superior endplate in M2 model and the L5 superior endplate in M3 model showed the maximum peak von Mises stress,and the peak von Mises stresses of L4 and L5 superior endplates in M4 and M5 models were close.The L3/4 cage in M2 model and the L4/5 cage in M3 model showcased the largest peak von Mises stress,and the peak von Mises stresses of cages in M4 and M5 models were close.The peak stresses of internal fixation in M2-M5 models were close.Conclusion Four-screw fixation can replace 6-screw fixation in the OLIF surgery for treating two-level degenerative lumbar diseases.


Assuntos
Parafusos Ósseos , Análise de Elementos Finitos , Vértebras Lombares , Fusão Vertebral , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Humanos , Vértebras Lombares/cirurgia
17.
Heliyon ; 10(12): e32733, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38975150

RESUMO

Current noninvasive methods of clinical practice often do not identify the causes of conductive hearing loss due to pathologic changes in the middle ear with sufficient certainty. Wideband acoustic immittance (WAI) measurement is noninvasive, inexpensive and objective. It is very sensitive to pathologic changes in the middle ear and therefore promising for diagnosis. However, evaluation of the data is difficult because of large interindividual variations. Machine learning methods like Convolutional neural networks (CNN) which might be able to deal with this overlaying pattern require a large amount of labeled measurement data for training and validation. This is difficult to provide given the low prevalence of many middle-ear pathologies. Therefore, this study proposes an approach in which the WAI training data of the CNN are simulated with a finite-element ear model and the Monte-Carlo method. With this approach, virtual populations of normal, otosclerotic, and disarticulated ears were generated, consistent with the averaged data of measured populations and well representing the qualitative characteristics of individuals. The CNN trained with the virtual data achieved for otosclerosis an AUC of 91.1 %, a sensitivity of 85.7 %, and a specificity of 85.2 %. For disarticulation, an AUC of 99.5 %, sensitivity of 100 %, and specificity of 93.1 % was achieved. Furthermore, it was estimated that specificity could potentially be increased to about 99 % in both pathological cases if stapes reflex threshold measurements were used to confirm the diagnosis. Thus, the procedures' performance is comparable to classifiers from other studies trained with real measurement data, and therefore the procedure offers great potential for the diagnosis of rare pathologies or early-stages pathologies. The clinical potential of these preliminary results remains to be evaluated on more measurement data and additional pathologies.

18.
Artigo em Inglês | MEDLINE | ID: mdl-38963151

RESUMO

BACKGROUND: The incidence of cervical spondylosis is increasing, gradually affecting people's normal lives. Establishing a finite element model of the cervical spine is one of the methods for studying cervical spondylosis. MRI (Magnetic Resonance Imaging) still has certain difficulties in transitioning from human imaging to establishing muscle models suitable for finite element analysis. Medical software provides specific morphologies and can generate muscle finite element models. Additionally, there is little research on the static analysis of cervical spine finite element models with solid muscle. PURPOSE: A new method is proposed for establishing a finite element model of the cervical spine based on CT (Computed Tomography) data and medical software, and the model's effectiveness is validated. Human movement characteristics based on the force distribution in various parts are analyzed and predicted. METHODS: The muscle model is reconstructed in medical software and a three-dimensional finite element model of the entire cervical spine (C0-C7) is established by combining muscle models with CT vertebral data models. 1.5 Nm of load is applied to the finite element model to simulate the cervical spine movement. RESULTS: The finite element model was successfully established, and effectiveness was verified. Stress variations in various parts under six movements were obtained. The effectiveness of the model was basically verified. CONCLUSION: The finite element model of the cervical spine for mechanical analysis can be successfully established by using medical software and CT data. In daily life, the C2-3, C3-4, C4-C5 intervertebral discs, rectus capitis posterior major, longus colli, and obliquus capitis inferior are more prone to injury.

19.
Clin Oral Investig ; 28(8): 439, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39037593

RESUMO

OBJECTIVES: To conduct a finite element analysis of the impact of different variables on tooth sectioning efficiency and trauma to surrounding tissues when utilizing high-speed surgical handpieces and elevators. METHODS: CBCT data from the horizontally impacted third mandibular molar (M3M) of a patient were utilized to establish digital models of the M3M, adjacent M2M, and surrounding bone. To simulate tooth sectioning, a 3D finite element model was established with the following variables: remaining tooth tissue thickness (1-5 mm), tooth section fissure width (1-3 mm), elevator depth in fissure (2-6 mm), elevator position (buccal, lingual, central), elevator width (2-5 mm), and application of force (rotating, levering). Using this model, the distribution of stress on the M3M and the surrounding tissue was assessed while measuring tooth sectioning efficiency and trauma to the surrounding tissue. RESULTS: Factors associated with uniform stress at the site of sectioning included thin (≤ 3 mm) remaining tooth tissue, appropriate fissure width (~ 2 mm), a wide (≥ 4 mm) elevator, and central elevator positioning. Levering the elevator yielded greater stress on the M3M than rotating force. Greater sectioning efficiency was associated with increased stress placed on the distobuccal side of M2M. CONCLUSIONS: Tooth sectioning efficiency can be improved by adjusting the high-speed surgical handpiece and elevator. However, it is important to remain attentive to the trauma to which adjacent teeth are exposed during this process. CLINICAL SIGNIFICANCE: These results offer guidance for approaches to improving operator efficiency and reducing trauma to surrounding tissues during tooth sectioning.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Análise de Elementos Finitos , Mandíbula , Dente Serotino , Dente Impactado , Humanos , Dente Serotino/cirurgia , Dente Impactado/cirurgia , Dente Impactado/diagnóstico por imagem , Mandíbula/cirurgia , Imageamento Tridimensional , Equipamentos Odontológicos de Alta Rotação , Análise do Estresse Dentário
20.
Polymers (Basel) ; 16(14)2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39065373

RESUMO

Carbon Fiber Reinforced Polymers (CFRP) have become increasingly significant in real-world applications due to their superior strength-to-weight ratio, corrosion resistance, and high stiffness. These properties make CFRP an ideal material for reinforcing concrete structures, particularly in scenarios where weight reduction is crucial, such as in bridges and high-rise buildings. The transformative potential of CFRP lies in its ability to enhance the durability and load-bearing capacity of concrete structures while minimizing maintenance costs and extending the lifespan of the infrastructure. This research explores the impact of reinforcing structural elements with advanced composite materials on the strength and durability of concrete and reinforced concrete structures. By integrating Carbon Fiber Reinforced Polymer (CFRP) reinforcements, we subjected both rectangular and T-section concrete beams to comprehensive three-point bending tests, revealing a substantial increase in flexural strength by 45% and crack resistance due to CFRP reinforcement. The study revealed that CFRP reinforcement increased the flexural strength of concrete beams by 45% and improved crack resistance significantly. Additionally, the load-bearing capacity of the beams was enhanced by 40% compared to unreinforced specimens. These improvements were validated through finite element simulations, which showed a close alignment with the experimental data. Furthermore, an innovative simulation study was conducted using a finely tuned finite element numerical model within the Abaqus calculation code. This model accurately replicated the laboratory specimens in terms of shape, dimensions, and loading conditions. The simulation results not only validated the experimental observations but also provided deeper insights into the stress distribution and failure mechanisms of the reinforced beams. Novel aspects of this study include the identification of specific failure patterns unique to CFRP-reinforced beams and the introduction of an enhanced interaction model that more accurately reflects the composite behavior under load. In CFRP-reinforced beams, specific failure patterns were identified, including flexural cracks in the tension zone and debonding of the CFRP sheets. These patterns indicate the points of maximum stress concentration and potential weaknesses in the reinforcement strategy. The study revealed that while CFRP significantly improves the overall strength and stiffness, careful attention must be given to the bonding process and the quality of the adhesive used to ensure optimal performance. These findings contribute significantly to the understanding of material interactions and structural performance, offering new pathways for the design and optimization of composite-reinforced concrete structures. This research underscores the transformative potential of composite materials in elevating the structural integrity and longevity of concrete infrastructures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA