Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Biochimie ; 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39038731

RESUMO

This study examines how FOF1-ATPase, hydrogenases (Hyd-1 and Hyd-2), and potassium transport systems (TrkA) interact to maintain the proton motive force (pmf) in E. coli during fermentation of different glucose concentrations (2 g L-1 and 8 g L-1). Our findings indicate that mutants lacking the hyaA-hyaC genes exhibited a 30 % increase in total proton flux compared to the wild type when grown with 2 g L-1 glucose. This has been observed during assays where similar glucose levels were supplemented. Disruptions in proton pumping, particularly in hyaB and hyaC single mutants, led to increased potassium uptake. The hyaB mutant showed a threefold increase in the contribution of FOF1-ATPase to proton flux, suggesting a significant role for Hyd-1 in proton translocation. In the hybC mutant grown in 2 g L-1 glucose conditions, DCCD-sensitive fluxes decreased by 70 %, indicating critical role of Hyd-2 in proton transport and FOF1 function. When cells were grown with 8 g L-1 glucose, the 2H+/1K+ ratio was significantly disturbed in both wild type and mutants. Despite these perturbances, mutants with disruptions in Hyd-1 and Hyd-2 maintained constant FOF1 function, suggesting that this enzyme remains stable in glucose-rich environments. These results provide valuable insights into how Hyd-1 and Hyd-2 contribute to the regulation of ion transport, particularly proton translocation, in response to glucose concentration. Our study uncovered potential complementary mechanisms between Hyd-1 and Hyd-2 subunits, suggesting a complex interplay between these enzymes via metabolic cross talk with FOF1 in response to glucose concentrations to maintain pmf.

2.
Heliyon ; 10(11): e31784, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38845993

RESUMO

Background: This study investigated the effects of purple sweet potato anthocyanins (PSPA) in a type 2 diabetes mellitus (T2DM) mouse model. Methods: Sixty-five male mice were randomly divided into one control group and four experimental groups, which were fed with a high-fat diet and intraperitoneally injected with streptozotocin (STZ) to induce T2DM. The model mice were treated with 0 (M), 227.5 (LP), 455 (MP), or 910 (HP) mg/kg PSPA for ten days. ELISA, 16S rRNA sequencing, and hematoxylin and eosin staining were used to assess blood biochemical parameters, gut microbial composition, and liver tissue structure, respectively. Results: The FBG concentration was significantly decreased in the LP (6.32 ± 1.05 mmol/L), MP (6.32 ± 1.05 mmol/L), and HP (5.65 ± 0.83 mmol/L) groups; the glycosylated hemoglobin levels were significantly decreased in the HP group (14.43 ± 7.12 pg/mL) compared with that in the M group (8.08 ± 1.04 mmol/L; 27.20 ± 7.72 pg/mL; P < 0.05). The PSPA treated groups also increased blood glutathione levels compared with M. PSPA significantly affected gut microbial diversity. The Firmicutes/Bacteroidetes ratio decreased by 38.9 %, 49.2 %, and 15.9 % in the LP, MP, and HP groups compared with that in the M group (0.62). The PSPAs treated groups showed an increased relative abundance of Lachnospiraceae_Clostridium, Butyricimonas, and Akkermansia and decreased abundance of nine bacterial genera, including Staphylococcus. Conclusion: PSPA reduced blood glucose levels, increased serum antioxidant enzymes, and optimized the diversity and structure of the gut microbiota in mice with T2DM.

3.
Micromachines (Basel) ; 15(6)2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38930728

RESUMO

In this paper, a sensor using a complementary split ring resonator (CSRR) is proposed for non-destructive testing of blood glucose. By depicting the complementary split ring structure on the ground, the electromagnetic field strength between the split rings can be enhanced effectively. The structure size of the sensor by CSRR is determined by simulation, so that the insertion loss curve of the device has a resonance point at the frequency of 3.419 GHz. With a special holder created by three-dimensional (3D) printing technology, the test platform was established when the concentration of the solution varied from 0 mg/mL to 20 mg/mL. The experimental results indicate that there is an obvious linear relationship between the insertion loss S21 and the glucose concentration at the resonant frequency. Similarly, the measured real part and imaginary part of the S21 both vary with glucose concentration linearly. Based on the above experimental results, the feasibility of the sensor using a CSRR proposed in this paper for non-destructive detection of blood glucose is preliminarily verified.

4.
Cureus ; 16(5): e60745, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38903374

RESUMO

Background The management of diabetes is critically dependent on the continuous monitoring of blood glucose levels. Contemporary approaches primarily utilize invasive methods, which often prove to be uncomfortable and can deter patient adherence. There is a pressing need for the development of novel strategies that improve patient compliance and simplify the process of glucose monitoring. Aim and objectives The primary objective of this research is to develop a non-invasive blood glucose monitoring system (NIBGMS) that offers a convenient alternative to conventional invasive methods. This study aims to demonstrate the feasibility and accuracy of using visible laser light at a wavelength of 650 nm for glucose monitoring and to address physiological and technical challenges associated with in vivo measurements. Methods Our approach involved the design of a device that exploits the quantitative relationship between glucose concentration and the refraction phenomena of laser light. The system was initially calibrated and tested using glucose solutions across a range of concentrations (25-500 mg/dL). To get around the problems that come up when people's skin and bodies are different, we combined an infrared (IR) transmitter (800 nm) and receiver that checks for changes in voltage, which are indicative of glucose levels. Results The prototype device was compared with a commercially available blood glucose monitor (Accu-Chek active machine; Roche Diabetes Care, Inc., Mumbai, India). The results demonstrated an average linearity of 95.7% relative to the Accu-Chek machine, indicating a high level of accuracy in the non-invasive measurement of glucose levels. Conclusions The findings suggest that our NIBGMS holds significant promise for clinical application. It reduces the discomfort associated with blood sampling and provides reliable measurements that are comparable to those of existing invasive methods. The successful development of this device paves the way for further commercial translation and could significantly improve the quality of life for individuals with diabetes, by facilitating easier and more frequent monitoring.

5.
J Wildl Dis ; 60(3): 634-646, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38741368

RESUMO

Pathogens have traditionally been studied in isolation within host systems; yet in natural settings they frequently coexist. This raises questions about the dynamics of co-infections and how host life-history traits might predict co-infection versus single infection. To address these questions, we investigated the presence of two parasites, a gut parasite (Isospora coccidians) and a blood parasite (Plasmodium spp.), in House Finches (Haemorhous mexicanus), a common passerine bird in North America. We then correlated these parasitic infections with various health and condition metrics, including hematological parameters, plasma carotenoids, lipid-soluble vitamins, blood glucose concentration, body condition, and prior disease history. Our study, based on 48 birds captured in Tempe, Arizona, US, in October 2021, revealed that co-infected birds exhibited elevated circulating lutein levels and a higher heterophil:lymphocyte ratio (H/L ratio) compared to those solely infected with coccidia Isospora spp. This suggests that co-infected birds experience heightened stress and may use lutein to bolster immunity against both pathogens, and that there are potentially toxic effects of lutein in co-infected birds compared to those infected solely with coccidia Isospora sp. Our findings underscore the synergistic impact of coparasitism, emphasizing the need for more co-infection studies to enhance our understanding of disease dynamics in nature, as well as its implications for wildlife health and conservation efforts.


Assuntos
Doenças das Aves , Coccidiose , Coinfecção , Tentilhões , Isospora , Malária Aviária , Plasmodium , Animais , Tentilhões/parasitologia , Coinfecção/veterinária , Coinfecção/parasitologia , Coinfecção/epidemiologia , Malária Aviária/epidemiologia , Malária Aviária/parasitologia , Malária Aviária/sangue , Doenças das Aves/parasitologia , Doenças das Aves/epidemiologia , Doenças das Aves/sangue , Isospora/isolamento & purificação , Coccidiose/veterinária , Coccidiose/epidemiologia , Coccidiose/parasitologia , Plasmodium/isolamento & purificação , Isosporíase/veterinária , Isosporíase/epidemiologia , Isosporíase/parasitologia , Arizona/epidemiologia , Masculino , Feminino
6.
Ann Clin Biochem ; : 45632241249034, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38591468

RESUMO

BACKGROUND: It is important that blood glucose concentrations be accurately and conveniently measured in infants. However, especially in the early neonatal period, point-of-care testing devices used for adults may not accurately measure blood glucose concentrations in neonates. METHODS: In Study 1, the accuracy of neonatal whole-blood glucose measurements was evaluated for the existing glucose analyser Glutest Mint® (hereinafter MINT1; Sanwa Kagaku Kenkyusho, Nagoya, Japan) by comparing the data with reference blood glucose concentrations. In Study 2, we used MINT2, which was modified based on the findings from Study 1, to measure whole-blood glucose concentrations in newborns, and the accuracy of the measurements was compared with that of MINT1. RESULTS: Blood glucose concentrations were measured in 100 infants each in Study 1 and 2. In Study 1, the whole-blood glucose concentrations measured using MINT1 were found to be significantly lower than the reference blood glucose concentrations in early neonates. The results of Study 1 suggested that characteristics of erythrocyte membranes in early neonates affected the measurements. Therefore, we conducted Study 2 using MINT2, which was modified to be less susceptible. MINT2 was found to accurately measure whole-blood glucose concentrations in the early neonatal period. CONCLUSION: The study showed that the point-of-care testing device could be improved to allow for accurate whole-blood glucose measurements in the early neonatal period.

7.
Diabetes Metab Syndr Obes ; 17: 1267-1278, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38496005

RESUMO

Objective: In this study, we aimed to evaluate the current status of the quality of life (QOL) of pediatric patients and plasma glucose concentration regulation in children with type 1 diabetes (T1DM) in the Ningxia Hui autonomous region. Methods: The study involved children with T1DM admitted to the General Hospital of Ningxia Medical University between October 2011 and October 2021. The children and their parents completed general information and quality of life (QOL) questionnaires. The regulation of plasma glucose concentration was assessed based on HbA1c levels, and plasma glucose and QOL-influencing components were investigated. Results: Among the 136 pediatric patients diagnosed with T1DM, the mean glycated hemoglobin (HbA1c) level was recorded at 8.7% (7.2%, 10.5%). A breakdown of the patient cohort revealed that 44 patients (32.4%) demonstrated good regulation of plasma glucose, 33 patients (24.3%) exhibited acceptable glycemic control, and 59 patients (43.3%) displayed poor regulation of plasma glucose. The control of plasma glucose in pediatric patients diagnosed with T1DM was affected by the duration of the disease, the patient's age, the frequency of daily plasma glucose measurements, the use of CGM, diabetic ketoacidosis (DKA), and the education level of the mother. The control of plasma glucose, dietary management, DKA, the ability to learn, and health education are interfering factors of quality of life in children diagnosed with T1DM. Effective control of plasma glucose may ensure the QOL in children with T1DM, and DKA was the risk factor for QOL. Conclusion: In Ningxia, the regulation of plasma glucose in pediatric and adolescent patients with T1DM remains suboptimal, leading to poor QOL. There is a pressing need to enhance glucose regulation and QOL through comprehensive strategies, which include reinforced dietary management, rigorous monitoring of plasma glucose levels, and heightened health education levels.

8.
J Int Med Res ; 52(3): 3000605241233515, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38452049

RESUMO

OBJECTIVES: We aimed to identify the prevalence, bacterial isolates, antimicrobial susceptibility profile, and factors associated with asymptomatic bacteriuria (ASB) in patients with type 2 diabetes mellitus (T2DM) in rural southwestern Nigeria. METHODS: We performed a hospital-based cross-sectional study of patients with T2DM and ASB. Demographic and clinical data were collected using questionnaires. Urine samples were cultured using standard laboratory procedures, and bacterial colonies were isolated and antimicrobial sensitivity was performed using the disc diffusion technique. Relationships between variables were assessed using adjusted odds ratios (AORs) and 95% confidence intervals (CIs). RESULTS: Of the 280 participants, 73 (26.1%) had ASB (95% CI: 20.9%-31.2%). The most commonly identified isolate was E. coli (45/73; 61.7%), 100.0% of which were sensitive to cefuroxime but resistant to ciprofloxacin. Female sex (AOR, 6.132; 95% CI: 2.327-16.157), living below the poverty line (AOR, 2.066; 95% CI: 1.059-4.029), uncontrolled blood glucose (AOR, 2.097; 95% CI: 1.000-4.404), and a history of indwelling urethral catheterization (AOR, 14.521; 95% CI: 4.914-42.908) were associated with ASB. CONCLUSION: The findings suggest that cefuroxime should be used as an empirical treatment, pending urine culture and sensitivity, and that efforts should be made to prevent ASB in rural southwestern Nigeria.


Assuntos
Anti-Infecciosos , Bacteriúria , Diabetes Mellitus Tipo 2 , Humanos , Feminino , Bacteriúria/tratamento farmacológico , Bacteriúria/epidemiologia , Bacteriúria/microbiologia , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/epidemiologia , Estudos Transversais , Escherichia coli , Cefuroxima , Nigéria/epidemiologia
9.
J Exp Zool A Ecol Integr Physiol ; 341(4): 440-449, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38385786

RESUMO

The development of inexpensive and portable point-of-care devices for measuring nutritional physiological parameters from blood (e.g., glucose, ketones) has accelerated our understanding and assessment of real-time variation in human health, but these have infrequently been tested or implemented in wild animals, especially in relation to other key biological or fitness-related traits. Here we used point-of-care devices to measure blood levels of glucose, ketones, uric acid, and triglycerides in free-ranging house finches (Haemorhous mexicanus)-a common songbird in North America that has been well-studied in the context of urbanization, nutrition, health, and sexual selection-during winter and examined (1) repeatability of these methods for evaluating blood levels in these wild passerines, (2) intercorrelations among these measurements within individuals, (3) how blood nutritional-physiology metrics related to a bird's body condition, habitat of origin (urban vs. suburban), poxvirus infection, and sex; and (4) if the expression of male sexually selected plumage coloration was linked to any of the nutritional-physiological metrics. All blood-nutritional parameters were repeatable. Also, there was significant positive covariation between concentrations of circulating triglycerides and glucose and triglycerides and uric acid. Urban finches had higher blood glucose concentrations than suburban finches, and pox-infected individuals had lower blood triglyceride concentrations than uninfected ones. Last, redder males had higher blood glucose, but lower uric acid levels. These results demonstrate that point-of-care devices can be useful, inexpensive ways of measuring real-time variation in the nutritional physiology of wild birds.


Assuntos
Tentilhões , Passeriformes , Infecções por Poxviridae , Humanos , Masculino , Animais , Tentilhões/fisiologia , Urbanização , Ácido Úrico/metabolismo , Glicemia , Sistemas Automatizados de Assistência Junto ao Leito , Animais Selvagens , Ecossistema , Fenômenos Fisiológicos da Nutrição , Cetonas/metabolismo , Triglicerídeos
10.
ACS Sens ; 9(3): 1199-1207, 2024 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-38372695

RESUMO

Enzymes are essential to life and indispensable in a wide range of industries (food, pharmaceutical, medical, biosensing, etc.); however, a significant shortcoming of these fragile biological catalysts is their poor stability. To address this challenge, a variety of immobilization methods have been described to enhance the enzyme's stability. These immobilization methods generally are specific to an individual enzyme or optimal for a particular application. The aim of this study is to explore the utility of porous, indicator moiety-tagged, polymeric nanocapsules (NCs) for the encapsulation of enzymes and measurement of the enzyme's substrate. As a model enzyme, glucose oxidase (GOx) is used. The GOx enzyme-loaded, fluorophore-tagged NCs were synthesized by using self-assembled surfactant vesicle templates. To show that the biological activity of GOx is preserved during entrapment, the rate of the GOx enzyme catalyzed reaction was measured. To evaluate the protective features of the porous NCs, the encapsulated GOx enzyme activity was followed in the presence of hydrolytic enzymes. During the encapsulation of GOx and the purification of the GOx-loaded NCs, the GOx activity decayed less than 10%, and up to 30% of the encapsulated GOx activity could be retained for 3-5 days in the presence of hydrolytic enzymes. In support of the potentially unique advantages of the enzyme-loaded NCs, as a proof-of-concept example, the fluorophore-tagged, GOx-loaded NCs were used for the determination of glucose in the concentration range between 18 and 162 mg/dL and for imaging the distribution of glucose concentration in imaging experiments.


Assuntos
Nanocápsulas , Enzimas Imobilizadas , Porosidade , Polímeros , Glucose , Indicadores e Reagentes , Glucose Oxidase
11.
Rev. mex. ing. bioméd ; 44(2): 1334, May.-Aug. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1536653

RESUMO

ABSTRACT With an estimated approximately 2 million deaths per year, diabetes is one of the top 5 deadliest noncommunicable diseases globally. Although this disease is not fatal, the degradation of the patient's health due to a bad plan to control their glucose levels can have a fatal outcome. In order to lay the foundations for the development of a device that allows estimating glucose levels in some body fluid, we present the results obtained not only for the estimation of glucose in deionized water, but also describe the development and configuration of the created device. After analyzing 50 signals obtained from 5 different glucose concentrations, the feasibility of using the developed device for the analysis is evident, since, considering the K-Nearest Neighbors (KNN) algorithm, all the signals were associated correctly to the glucose group to which they belong.


RESUMEN Con un estimado de aproximadamente 2 millones de muertes por año, la diabetes es una de las 5 enfermedades no transmisibles más mortales a nivel mundial. Aunque esta enfermedad no es mortal, el deterioro de la salud del paciente por un mal plan para controlar sus niveles de glucosa puede tener un desenlace fatal. Con el fin de sentar las bases para el desarrollo de un dispositivo que permita estimar los niveles de glucosa en algún fluido corporal, presentamos los resultados obtenidos no solo para la estimación de glucosa en agua desionizada, sino que también describimos el desarrollo y configuración del dispositivo creado. Luego de analizar 50 señales obtenidos a partir de 5 concentraciones de glucosa diferentes, se evidencia la factibilidad de utilizar el dispositivo desarrollado para el análisis, ya que, considerando el algoritmo K-Nearest Neighbors (KNN), todas las señales se asociaron correctamente al grupo de glucosa al que pertenecen.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA