Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 585
Filtrar
1.
J Med Life ; 17(4): 442-448, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-39071510

RESUMO

Inflammatory illnesses, such as periodontitis and atherosclerotic coronary heart disease (ASCHD), trigger the production of pro-inflammatory mediators. The aim of this study was to assess the accuracy of using salivary interleukin-1ß (IL-1ß), interleukin-18 (IL-18), and gasdermin D (GSDMD) in discerning patients with periodontitis with and without ASCHD from healthy individuals, and to assess their correlation with clinical periodontal parameters and low-density lipoprotein (LDL) levels. The study involved 120 participants: 30 were healthy subjects (control group, C), 30 had generalized periodontitis (group P), 30 had ASCHD and clinically healthy periodontium (group AS-C), and 30 had ASCHD and generalized periodontitis (group AS-P). Saliva and blood samples were collected, and periodontal characteristics such as plaque index, bleeding on probing, probing pocket depth, and clinical attachment loss were examined. IL-1ß, IL-18, and GSDMD levels from saliva were determined using ELISA. LDL levels were determined from the blood samples. Groups P, AS-C, and AS-P had higher levels of salivary IL-1ß, IL-18, and GSDMD than group C. The receiver operating characteristic (ROC) curves of all biomarkers showed high diagnostic accuracy, with a significant positive correlation with the clinical parameters and LDL levels. The observed correlations between the studied pro-inflammatory mediators and disease severity suggest that these biomarkers could serve as indicators of disease progression in conditions such as periodontitis and ASCHD.


Assuntos
Biomarcadores , Doença das Coronárias , Interleucina-18 , Interleucina-1beta , Saliva , Humanos , Biomarcadores/metabolismo , Biomarcadores/sangue , Saliva/metabolismo , Saliva/química , Interleucina-18/sangue , Interleucina-18/metabolismo , Interleucina-18/análise , Masculino , Feminino , Interleucina-1beta/sangue , Interleucina-1beta/metabolismo , Interleucina-1beta/análise , Pessoa de Meia-Idade , Doença das Coronárias/diagnóstico , Doença das Coronárias/metabolismo , Doença das Coronárias/sangue , Periodontite/diagnóstico , Periodontite/metabolismo , Periodontite/sangue , Adulto , Proteínas de Ligação a Fosfato/metabolismo , Curva ROC , Estudos de Casos e Controles , Gasderminas
2.
Sci Rep ; 14(1): 16461, 2024 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-39013962

RESUMO

In this work, we present a novel preclinical device utilizing Torsional Wave Elastography (TWE). It comprises a rotational actuator element and a piezoceramic receiver ring circumferentially aligned. Both allow the transmission of shear waves that interact with the tissue before being received. Our main objective is to demonstrate and characterize the reliability, robustness, and accuracy of the device for characterizing the stiffness of elastic materials and soft tissues. Experimental tests are performed using two sets of tissue mimicking phantoms. The first set consists of calibrated CIRS gels with known stiffness value, while the second test uses non-calibrated manufactured phantoms. Our experimental observations show that the proposed device consistently and repeatably quantifies the stiffness of elastic materials with high accuracy. Furthermore, comparison with established techniques demonstrates a very high correlation (> 95%), supporting the potential medical application of this technology. The results obtained pave the way for a cross-sectional study aiming to investigate the correlation between gestational age and cervical elastic properties during pregnancy.


Assuntos
Técnicas de Imagem por Elasticidade , Imagens de Fantasmas , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/instrumentação , Humanos , Reprodutibilidade dos Testes , Feminino , Gravidez , Elasticidade , Desenho de Equipamento
3.
Int J Surg Pathol ; : 10668969241260226, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-39034304

RESUMO

The nonalcoholic steatohepatitis clinical research network (NASH-CRN) system is commonly used for histologic assessment of disease activity and fibrosis in NASH. Despite this, the system does not fully capture the range of disease activity and fibrosis. As such, an expanded NAS (E-NAS) grading and staging system with a calculated E-NAS index was developed by our group. In this follow up study, we aim to revalidate the E-NAS system and compare its reliability to existing systems. Hematoxylin and eosin and trichrome stained sections from 40 liver biopsies were reviewed digitally by four hepatopathologists and assessed using the NASH-CRN and E-NAS systems as well as a modified Ishak fibrosis stage. The pathologist's gestalt impression of disease activity and fibrosis was scored on a Visual Analogue Scale (VAS), which ranged from 0 (no activity/fibrosis) to 100 (the worst activity/fibrosis ever seen). Inter-rater reliability was assessed, and Spearman correlation coefficients were calculated. The E-NAS index had higher inter-rater agreement versus the NAS score (ICC 0.70 vs 0.61). The inter-rater agreement for ballooning in the E-NAS system was also higher at 0.67 compared to the NAS (ICC 0.60). ICCs for fibrosis were comparable between all the systems assessed (0.78 to 0.88). Finally, the calculated E-NAS index was higher with increasing stage of fibrosis compared to the NAS suggesting that it associates better with fibrosis. In summary, the E-NAS system demonstrates substantial inter-rater reliability as well as improved correlation with disease activity VAS and fibrosis compared to the NAS score.

4.
J Appl Clin Med Phys ; 25(8): e14442, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38922790

RESUMO

PURPOSE: To propose radiomics features as a superior measure for evaluating the segmentation ability of physicians and auto-segmentation tools and to compare its performance with the most commonly used metrics: Dice similarity coefficient (DSC), surface Dice similarity coefficient (sDSC), and Hausdorff distance (HD). MATERIALS/METHODS: The data of 10 lung cancer patients' CT images with nine tumor segmentations per tumor were downloaded from the RIDER (Reference Database to Evaluate Response) database. Radiomics features of 90 segmented tumors were extracted using the PyRadiomics program. The intraclass correlation coefficient (ICC) of radiomics features were used to evaluate the segmentation similarity and compare their performance with DSC, sDSC, and HD. We calculated one ICC per radiomics feature and per tumor for nine segmentations and 36 ICCs per radiomics feature for 36 pairs of nine segmentations. Meanwhile, there were 360 DSC, sDSC, and HD values calculated for 36 pairs for 10 tumors. RESULTS: The ICC of radiomics features exhibited greater sensitivity to segmentation changes than DSC and sDSC. The ICCs of the wavelet-LLL first order Maximum, wavelet-LLL glcm MCC, wavelet-LLL glcm Cluster Shade features ranged from 0.130 to 0.997, 0.033 to 0.978, and 0.160 to 0.998, respectively. On the other hand, all DSC and sDSC were larger than 0.778 and 0.700, respectively, while HD varied from 0 to 1.9 mm. The results indicated that the radiomics features could capture subtle variations in tumor segmentation characteristics, which could not be easily detected by DSC and sDSC. CONCLUSIONS: This study demonstrates the superiority of radiomics features with ICC as a measure for evaluating a physician's tumor segmentation ability and the performance of auto-segmentation tools. Radiomics features offer a more sensitive and comprehensive evaluation, providing valuable insights into tumor characteristics. Therefore, the new metrics can be used to evaluate new auto-segmentation methods and enhance trainees' segmentation skills in medical training and education.


Assuntos
Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares , Radiômica , Tomografia Computadorizada por Raios X , Humanos , Algoritmos , Bases de Dados Factuais , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos
5.
Front Neurosci ; 18: 1405734, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38855440

RESUMO

Objective: In this work, we propose a novel method for constructing whole-brain spatio-temporal multilayer functional connectivity networks (FCNs) and four innovative rich-club metrics. Methods: Spatio-temporal multilayer FCNs achieve a high-order representation of the spatio-temporal dynamic characteristics of brain networks by combining the sliding time window method with graph theory and hypergraph theory. The four proposed rich-club scales are based on the dynamic changes in rich-club node identity, providing a parameterized description of the topological dynamic characteristics of brain networks from both temporal and spatial perspectives. The proposed method was validated in three independent differential analysis experiments: male-female gender difference analysis, analysis of abnormality in patients with autism spectrum disorders (ASD), and individual difference analysis. Results: The proposed method yielded results consistent with previous relevant studies and revealed some innovative findings. For instance, the dynamic topological characteristics of specific white matter regions effectively reflected individual differences. The increased abnormality in internal functional connectivity within the basal ganglia may be a contributing factor to the occurrence of repetitive or restrictive behaviors in ASD patients. Conclusion: The proposed methodology provides an efficacious approach for constructing whole-brain spatio-temporal multilayer FCNs and conducting analysis of their dynamic topological structures. The dynamic topological characteristics of spatio-temporal multilayer FCNs may offer new insights into physiological variations and pathological abnormalities in neuroscience.

6.
PNAS Nexus ; 3(5): pgae200, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38818238

RESUMO

Cooperation in the Public Goods Game (PGG) is determined by a mixture of individual differences (e.g. personality, social preferences) and group dynamics (e.g. reciprocation, social norms). However, to our knowledge, no thorough attempt has been made to separate individual and group levels of cooperation and to quantify the variance in cooperation that can be attributed to the group level. In an analysis of 10 open datasets (total N = 4,556, 1,003 groups, 7-50 rounds), we chart the trajectory of individual and group-level variance across rounds of repeated PGGs. We find that the portion of group-level variance increases initially and plateaus around the fifth round, typically at a level between 20 and 50%. In addition, we identify four factors that increase the portion of group-level variance: (i) punishment opportunities; (ii) detailed feedback including all group members' decisions; (iii) small groups (≤4 players); and (iv) groups with homogenous social preferences.

7.
Hum Brain Mapp ; 45(7): e26666, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38726831

RESUMO

Advanced meditation such as jhana meditation can produce various altered states of consciousness (jhanas) and cultivate rewarding psychological qualities including joy, peace, compassion, and attentional stability. Mapping the neurobiological substrates of jhana meditation can inform the development and application of advanced meditation to enhance well-being. Only two prior studies have attempted to investigate the neural correlates of jhana meditation, and the rarity of adept practitioners has largely restricted the size and extent of these studies. Therefore, examining the consistency and reliability of observed brain responses associated with jhana meditation can be valuable. In this study, we aimed to characterize functional magnetic resonance imaging (fMRI) reliability within a single subject over repeated runs in canonical brain networks during jhana meditation performed by an adept practitioner over 5 days (27 fMRI runs) inside an ultra-high field 7 Tesla MRI scanner. We found that thalamus and several cortical networks, that is, the somatomotor, limbic, default-mode, control, and temporo-parietal, demonstrated good within-subject reliability across all jhanas. Additionally, we found that several other relevant brain networks (e.g., attention, salience) showed noticeable increases in reliability when fMRI measurements were adjusted for variability in self-reported phenomenology related to jhana meditation. Overall, we present a preliminary template of reliable brain areas likely underpinning core neurocognitive elements of jhana meditation, and highlight the utility of neurophenomenological experimental designs for better characterizing neuronal variability associated with advanced meditative states.


Assuntos
Imageamento por Ressonância Magnética , Meditação , Rede Nervosa , Humanos , Reprodutibilidade dos Testes , Rede Nervosa/fisiologia , Rede Nervosa/diagnóstico por imagem , Adulto , Masculino , Feminino , Encéfalo/fisiologia , Encéfalo/diagnóstico por imagem , Córtex Cerebral/fisiologia , Córtex Cerebral/diagnóstico por imagem
8.
Psychiatry Res Neuroimaging ; 341: 111823, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38735229

RESUMO

Arterial Spin Labeling is a valuable functional imaging tool for both clinical and research purposes. However, little is known about the test-retest reliability of cerebral blood flow measurements over longer periods. In this study, we investigated the reliability of pulsed Arterial Spin Labeling in assessing cerebral blood flow over a 3 (n = 28) vs 8 (n = 19) weeks interscan interval in 47 healthy participants. As a measure of cerebral blood flow reliability, we calculated voxel-wise, whole-brain, and regions of interest intraclass correlation coefficients. The whole-brain mean resting-state cerebral blood flow showed good to excellent reliability over time for both periods (intraclass correlation coefficients = 0.85 for the 3-week delay, intraclass correlation coefficients = 0.53 for the 8-week delay). However, the voxel-wise and regions of interest intraclass correlation coefficients fluctuated at 8-week compared to the 3-week interval, especially within cortical areas. These results confirmed previous findings that Arterial Spin Labeling could be used as a reliable method to assess brain perfusion. However, as the reliability seemed to decrease over time, caution is warranted when performing correlations with other variables, especially in clinical populations.


Assuntos
Encéfalo , Circulação Cerebrovascular , Marcadores de Spin , Humanos , Circulação Cerebrovascular/fisiologia , Masculino , Feminino , Adulto , Reprodutibilidade dos Testes , Adulto Jovem , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Fatores de Tempo , Descanso/fisiologia
9.
Cereb Cortex ; 34(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38771245

RESUMO

Arterial spin-labeled perfusion and blood oxygenation level-dependent functional MRI are indispensable tools for noninvasive human brain imaging in clinical and cognitive neuroscience, yet concerns persist regarding the reliability and reproducibility of functional MRI findings. The circadian rhythm is known to play a significant role in physiological and psychological responses, leading to variability in brain function at different times of the day. Despite this, test-retest reliability of brain function across different times of the day remains poorly understood. This study examined the test-retest reliability of six repeated cerebral blood flow measurements using arterial spin-labeled perfusion imaging both at resting-state and during the psychomotor vigilance test, as well as task-induced cerebral blood flow changes in a cohort of 38 healthy participants over a full day. The results demonstrated excellent test-retest reliability for absolute cerebral blood flow measurements at rest and during the psychomotor vigilance test throughout the day. However, task-induced cerebral blood flow changes exhibited poor reliability across various brain regions and networks. Furthermore, reliability declined over longer time intervals within the day, particularly during nighttime scans compared to daytime scans. These findings highlight the superior reliability of absolute cerebral blood flow compared to task-induced cerebral blood flow changes and emphasize the importance of controlling time-of-day effects to enhance the reliability and reproducibility of future brain imaging studies.


Assuntos
Encéfalo , Circulação Cerebrovascular , Imageamento por Ressonância Magnética , Descanso , Humanos , Masculino , Feminino , Adulto , Circulação Cerebrovascular/fisiologia , Reprodutibilidade dos Testes , Descanso/fisiologia , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Encéfalo/irrigação sanguínea , Adulto Jovem , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Desempenho Psicomotor/fisiologia , Ritmo Circadiano/fisiologia , Nível de Alerta/fisiologia
10.
J Med Life ; 17(2): 226-232, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38813369

RESUMO

Renal calculi are a common clinical presentation. While ultrasound (US) is a widely used imaging modality for kidney stone diagnosis due to its accessibility and lower cost, its accuracy compared to computerized tomography (CT), the gold standard, remains understudied. This cross-sectional study evaluated the diagnostic accuracy of ultrasound for detecting and characterizing kidney stones compared to computed tomography (CT). Fifty-six patients with suspected kidney stones based on flank pain underwent abdominal ultrasound to assess stone presence, size, location, and the severity of any hydronephrosis (kidney swelling). These findings were then confirmed with a subsequent non-contrast CT scan. There was a fair agreement between US and CT (Kappa = 0.368) for detecting the stone location. The US could not detect 7 (12.5%) stones, being less sensitive in the middle and upper calyx compared to CT. There was a fair agreement between the US and CT (Kappa = 0.394) for detecting the severity of hydronephrosis. The US was less sensitive to moderate and severe hydronephrosis compared to CT. The abdominal ultrasound demonstrated excellent reliability for stone size measurement (intraclass correlation = 0.924), with CT measurements only slightly larger on average (mean difference 0.9 mm). Although abdominal ultrasound provides reliable stone size assessment, its capacity to accurately localize stones and assess hydronephrosis severity is limited.


Assuntos
Cálculos Renais , Tomografia Computadorizada por Raios X , Ultrassonografia , Humanos , Ultrassonografia/métodos , Cálculos Renais/diagnóstico por imagem , Feminino , Estudos Transversais , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Adulto , Hidronefrose/diagnóstico por imagem , Idoso , Reprodutibilidade dos Testes
11.
bioRxiv ; 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38645002

RESUMO

High-amplitude co-activation patterns are sparsely present during resting-state fMRI but drive functional connectivity1-5. Further, they resemble task activation patterns and are well-studied3,5-10. However, little research has characterized the remaining majority of the resting-state signal. In this work, we introduced caricaturing-a method to project resting-state data to a subspace orthogonal to a manifold of co-activation patterns estimated from the task fMRI data. Projecting to this subspace removes linear combinations of these co-activation patterns from the resting-state data to create Caricatured connectomes. We used rich task data from the Human Connectome Project (HCP)11 and the UCLA Consortium for Neuropsychiatric Phenomics12 to construct a manifold of task co-activation patterns. Caricatured connectomes were created by projecting resting-state data from the HCP and the Yale Test-Retest13 datasets away from this manifold. Like caricatures, these connectomes emphasized individual differences by reducing between-individual similarity and increasing individual identification14. They also improved predictive modeling of brain-phenotype associations. As caricaturing removes group-relevant task variance, it is an initial attempt to remove task-like co-activations from rest. Therefore, our results suggest that there is a useful signal beyond the dominating co-activations that drive resting-state functional connectivity, which may better characterize the brain's intrinsic functional architecture.

12.
Children (Basel) ; 11(4)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671610

RESUMO

Indulgent parenting has been associated with adolescents' psychological well-being problems; however, prior research has primarily relied on adolescents' report of such parenting behavior and its association with their own well-being, often overlooking parents' perceptions of indulgence and their own well-being. In this study, we address this gap in the literature by examining the agreement and disagreement between parents' and adolescents' perceptions of indulgent parenting and the implications for the psychological well-being of both adolescents and their parents. Further, we explore the role of adolescent-parent relationship satisfaction as a potential factor affecting these associations. Our investigation was based on data from 128 parent-adolescent dyads. Utilizing structural equation modeling with double-entry intraclass correlations (ICC_DE), our analyses revealed several main findings: (1) adolescents perceived higher levels of indulgent parenting than their parents did; (2) disagreement in perceived indulgent parenting between parents and adolescents was linked to psychological well-being problems for both adolescents and their parents; and (3) disagreement in perceptions in indulgent parenting had a stronger association with adolescents' well-being problems when adolescents reported greater relationship satisfaction with their parents. These findings provide insights into perceptions of indulgent parenting within parent-adolescent relationships and bring psychological implications for both adolescents and their parents.

13.
Int J Cardiovasc Imaging ; 40(6): 1257-1267, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38587689

RESUMO

PURPOSE: We aimed to evaluate the reproducibility of computed tomography (CT) radiomic features (RFs) about Epicardial Adipose Tissue (EAT). The features derived from coronary photon-counting computed tomography (PCCT) angiography datasets using the PureCalcium (VNCPC) and conventional virtual non-contrast (VNCConv) algorithm were compared with true non-contrast (TNC) series. METHODS: RFs of EAT from 52 patients who underwent PCCT were quantified using VNCPC, VNCConv, and TNC series. The agreement of EAT volume (EATV) and EAT density (EATD) was evaluated using Pearson's correlation coefficient and Bland-Altman analysis. A total of 1530 RFs were included. They are divided into 17 feature categories, each containing 90 RFs. The intraclass correlation coefficients (ICCs) and concordance correlation coefficients (CCCs) were calculated to assess the reproducibility of RFs. The cutoff value considered indicative of reproducible features was > 0.75. RESULTS: the VNCPC and VNCConv tended to underestimate EATVs and overestimate EATDs. Both EATV and EATD of VNCPC series showed higher correlation and agreement with TNC than VNCConv series. All types of RFs from VNCPC series showed greater reproducibility than VNCConv series. Across all image filters, the Square filter exhibited the highest level of reproducibility (ICC = 67/90, 74.4%; CCC = 67/90, 74.4%). GLDM_GrayLevelNonUniformity feature had the highest reproducibility in the original image (ICC = 0.957, CCC = 0.958), exhibiting a high degree of reproducibility across all image filters. CONCLUSION: The accuracy evaluation of EATV and EATD and the reproducibility of RFs from VNCPC series make it an excellent substitute for TNC series exceeding VNCConv series.


Assuntos
Tecido Adiposo , Algoritmos , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Pericárdio , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Humanos , Reprodutibilidade dos Testes , Tecido Adiposo/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Retrospectivos , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Adiposidade , Tecido Adiposo Epicárdico , Radiômica
14.
Am J Otolaryngol ; 45(4): 104323, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38677144

RESUMO

BACKGROUND: Subglottic stenosis (SGS) is a condition leading to narrowing of the upper airway which can lead to dyspnea and life-threatening airway obstruction. Although other proposed grading systems exist, the Cotton Myer (CM) and percent stenosis systems are the most widespread in clinical practice. Despite this, the CM system has not yet been validated for visual assessment of SGS. OBJECTIVE: To determine the interrater and intrarater reliability of the CM grading system among a cohort of physicians who manage patients with SGS. METHODS: An online survey created with videos of tracheoscopies from 20 adult patients with subglotticstenosis (SGS) was sent individually to 9 expert physicians from various medical specialties, all of whom managed patients with SGS. Physicians were asked to view the 20 tracheoscopy videos and assess both the percent stenosis and Cotton Myer (CM) grade of each patient. After a period of 4 weeks, the physicians were sent the same survey of the 20 tracheoscopy videos. The interrater and intrarater reliability was calculated using the intraclass correlation coefficient (ICC), a measurement used to evaluate the reliability (the extent to which a measurement can be replicated) of two or more raters measuring the same subject. RESULTS: Overall, CM and percent stenosis systems were found to have an ICC of 0.94 and 0.90 within the domain of interrater reliability, respectively, and ICC of 0.71 and 0.81 within the domain of intrarater reliability, respectively. CONCLUSION: Our findings suggest that the CM and percent stenosis grading systems remain a valid clinical tool to measure and communicate the severity of airway obstruction in SGS.


Assuntos
Laringoestenose , Índice de Gravidade de Doença , Humanos , Laringoestenose/diagnóstico , Reprodutibilidade dos Testes , Variações Dependentes do Observador , Adulto , Gravação em Vídeo , Inquéritos e Questionários , Masculino , Feminino
15.
bioRxiv ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38562804

RESUMO

Empirical studies reporting low test-retest reliability of individual blood oxygen-level dependent (BOLD) signal estimates in functional magnetic resonance imaging (fMRI) data have resurrected interest among cognitive neuroscientists in methods that may improve reliability in fMRI. Over the last decade, several individual studies have reported that modeling decisions, such as smoothing, motion correction and contrast selection, may improve estimates of test-retest reliability of BOLD signal estimates. However, it remains an empirical question whether certain analytic decisions consistently improve individual and group level reliability estimates in an fMRI task across multiple large, independent samples. This study used three independent samples (Ns: 60, 81, 119) that collected the same task (Monetary Incentive Delay task) across two runs and two sessions to evaluate the effects of analytic decisions on the individual (intraclass correlation coefficient [ICC(3,1)]) and group (Jaccard/Spearman rho) reliability estimates of BOLD activity of task fMRI data. The analytic decisions in this study vary across four categories: smoothing kernel (five options), motion correction (four options), task parameterizing (three options) and task contrasts (four options), totaling 240 different pipeline permutations. Across all 240 pipelines, the median ICC estimates are consistently low, with a maximum median ICC estimate of .43 - .55 across the three samples. The analytic decisions with the greatest impact on the median ICC and group similarity estimates are the Implicit Baseline contrast, Cue Model parameterization and a larger smoothing kernel. Using an Implicit Baseline in a contrast condition meaningfully increased group similarity and ICC estimates as compared to using the Neutral cue. This effect was largest for the Cue Model parameterization; however, improvements in reliability came at the cost of interpretability. This study illustrates that estimates of reliability in the MID task are consistently low and variable at small samples, and a higher test-retest reliability may not always improve interpretability of the estimated BOLD signal.

16.
J Clin Med ; 13(7)2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38610880

RESUMO

Background: Advancements in non-ionizing methods for quantifying spinal deformities are crucial for assessing and monitoring scoliosis. In this study, we analyzed the observer variability of a newly developed digital tool for quantifying body asymmetry from clinical photographs. Methods: Prospective observational multicenter study. Initially, a digital tool was developed using image analysis software, calculating quantitative measures of body asymmetry. This tool was integrated into an online platform that exports data to a database. The tool calculated 10 parameters, including angles (shoulder height, axilla height, waist height, right and left waistline angles, and their difference) and surfaces of the left and right hemitrunks (shoulders, waists, pelvises, and total). Subsequently, an online training course on the tool was conducted for twelve observers not involved in its development (six research coordinators and six spine surgeons). Finally, 15 standardized back photographs of adolescent idiopathic scoliosis patients were selected from a multicenter image bank, representing various clinical scenarios (different age, gender, curve type, BMI, and pre- and postoperative images). The 12 observers measured the photographs at two different times with a three-week interval. For the second round, the images were randomly mixed. Inter- and intra-observer variabilities of the measurements were analyzed using intraclass correlation coefficients (ICCs), and reliability was measured by the standard error of measurement (SEM). Group comparisons were made using Student's t-test. Results: The mean inter-observer ICC for the ten measurements was 0.981, the mean intra-observer ICC was 0.937, and SEM was 0.3-1.3°. The parameter with the strongest inter- and intra-observer validity was the difference in waistline angles 0.994 and 0.974, respectively, while the highest variability was found with the waist height angle 0.963 and 0.845, respectively. No test-retest differences (p > 0.05) were observed between researchers (0.948 ± 0.04) and surgeons (0.925 ± 0.05). Conclusion: We developed a new digital tool integrated into an online platform demonstrating excellent reliability and inter- and intra-observer variabilities for quantifying body asymmetry in scoliosis patients from a simple clinical photograph. The method could be used for assessing and monitoring scoliosis and body asymmetry without radiation.

17.
Foot (Edinb) ; 59: 102095, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38614012

RESUMO

Despite the growing interest, information regarding the psychometric properties of maximal voluntary isometric toe plantarflexion force and rate of force development (RFD) is lacking. Hence, we investigate the test-retest reliability and measurement error of these outcome measurement instruments measured with a custom-built dynamometer. Twenty-six healthy adults participated in a crossed design with four sessions separated by 5-7 days. RFD was quantified using manual onset and calculating the impulse and the slope in the following time windows: 0-50 ms, 0-100 ms, 0-150 ms, 0-200 ms, 0-250 ms. We estimated the systematic bias of the mean, the intraclass correlation coefficient (ICC) and standard error of measurement (SEM) from the agreement and consistency models. The ICC and the SEM agreement for maximal voluntary isometric toe plantarflexion force along the perpendicular axis were respectively 0.87 (95%CI: 0.76, 0.93) and 27 N (22, 32), while along the resultant of the perpendicular and anterior posterior axis they were 0.85 (0.73, 0.92) and 29 N (23, 35). The results of the consistency model were similar as the estimated variance for session was closer to zero. A systematic bias of the mean between session 1 and 3 was found. For the RFD variables, the ICC agreement ranged from 0.35 to 0.65. The measurement process was found to be reliable to assess maximal voluntary isometric toe plantarflexion force but not RFD. However, a familiarization session is mandatory and these results need to be confirmed in less coordinated (e.g. aging population) individuals.


Assuntos
Contração Isométrica , Dinamômetro de Força Muscular , Dedos do Pé , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Adulto , Contração Isométrica/fisiologia , Dedos do Pé/fisiologia , Adulto Jovem , Músculo Esquelético/fisiologia , Força Muscular/fisiologia , Voluntários Saudáveis
18.
Eval Rev ; : 193841X241241354, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38552214

RESUMO

Randomized experiments involving education interventions are typically implemented as cluster randomized trials, with schools serving as clusters. To design such a study, it is critical to understand the degree to which learning outcomes vary between versus within clusters (schools), specifically the intraclass correlation coefficient. It is also helpful to anticipate the benefits, in terms of statistical power, of collecting household data, testing students at baseline, or relying on administrative data on previous cohorts from the same school. We use data from multiple cluster-randomized trials in four Latin American countries to provide information on the intraclass correlations in early grade literacy outcomes. We also describe the proportion of variance explained by different types of covariates. These parameters will help future researchers conduct statistical power analysis, estimate the required sample size, and determine the necessity of collecting different types of baseline data such as child assessments, administrative data at the school level, or household surveys.

19.
Phys Med Biol ; 69(9)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38530298

RESUMO

Objective. Accurate and reproducible tumor delineation on positron emission tomography (PET) images is required to validate predictive and prognostic models based on PET radiomic features. Manual segmentation of tumors is time-consuming whereas semi-automatic methods are easily implementable and inexpensive. This study assessed the reliability of semi-automatic segmentation methods over manual segmentation for tumor delineation in head and neck squamous cell carcinoma (HNSCC) PET images.Approach. We employed manual and six semi-automatic segmentation methods (just enough interaction (JEI), watershed, grow from seeds (GfS), flood filling (FF), 30% SUVmax and 40%SUVmax threshold) using 3D slicer software to extract 128 radiomic features from FDG-PET images of 100 HNSCC patients independently by three operators. We assessed the distributional properties of all features and considered 92 log-transformed features for subsequent analysis. For each paired comparison of a feature, we fitted a separate linear mixed effect model using the method (two levels; manual versus one semi-automatic method) as a fixed effect and the subject and the operator as the random effects. We estimated different statistics-the intraclass correlation coefficient agreement (aICC), limits of agreement (LoA), total deviation index (TDI), coverage probability (CP) and coefficient of individual agreement (CIA)-to evaluate the agreement between the manual and semi-automatic methods.Main results. Accounting for all statistics across 92 features, the JEI method consistently demonstrated acceptable agreement with the manual method, with median values of aICC = 0.86, TDI = 0.94, CP = 0.66, and CIA = 0.91.Significance. This study demonstrated that JEI method is a reliable semi-automatic method for tumor delineation on HNSCC PET images.


Assuntos
Neoplasias de Cabeça e Pescoço , Neoplasias Pulmonares , Humanos , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Reprodutibilidade dos Testes , Fluordesoxiglucose F18 , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
20.
Clin Nutr ESPEN ; 60: 65-72, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38479941

RESUMO

BACKGROUND & AIMS: Ultrasonography (US) is a promising tool for assessing body composition, offering accuracy and accessibility. However, technician skills and equipment characteristics can impact measurement reliability. We aimed to evaluate the intra- and inter-rater reliability of two evaluators using A-mode Portable Ultrasound to measure muscle and fat thickness in Brazilian older adults. METHODS: Quantitative cross-sectional study carried out with 150 community-dwelling older adults of Campinas-SP-Brazil, recruited in a retirement preparation program and a geriatric outpatient care unit. Scans of nine anatomical points were performed using the portable ultrasound in A-mode (BodyMetrix Pro System BX2000; Livermore, CA), with 6 scans per location and 3 measurements taken by each evaluator. After the selection and analysis of the generated images, muscle and fat thickness were measured. Reliability estimates between measures of the same evaluator (intra-rater) and between evaluators (inter-rater) were assessed using intraclass correlation coefficients (ICC), and differences within and between technicians were assessed using one-way ANOVA. Analyses were carried out for the overall sample and stratified by sex and by nutritional status. RESULTS: Excellent ICC values (>0.90) were found for subcutaneous fat thickness in intra- and inter-rater reliability analyses. The lowest ICC values were observed for deep abdominal fat thickness measured by evaluator 1 (ICC = 0.90) and evaluator 2 (ICC = 0.87), as well as in the inter-rater analysis (ICC = 0.85). Muscle thickness measurements had satisfactory ICC values for triceps, biceps, anterior thigh, and calf, ranging from moderate to good (ICC 0.50-0.90). CONCLUSION: A portable A-mode ultrasound demonstrates excellent reliability among both intra- and inter-raters for assessing fat thickness but only moderate for muscle thickness in older adults. Hence, this could prompt inquiries regarding the sole reliance on this tool for quantifying muscle mass and examining sarcopenia in older adults. To our knowledge, this study represents the first assessment of reliability for a portable A-mode ultrasound device conducted with older adults.


Assuntos
Músculo Esquelético , Gordura Subcutânea , Humanos , Idoso , Reprodutibilidade dos Testes , Estudos Transversais , Ultrassonografia/métodos , Músculo Esquelético/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA