Resultados 1 - 20 de 278
Filtrar
1.
Jpn J Ophthalmol ; 2024 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-39356388

RESUMO

PURPOSE: To investigate the associations of tomographic parameters in anterior segment optical coherence tomography (AS-OCT) with sex and age in a cohort study. STUDY DESIGN: A cohort design. MATERIALS AND METHODS: AS-OCT data from 391 Japanese participants aged ≥ 35 years were obtained using swept-source OCT. In the cornea, the keratometric power at the flat (Kf) and steep (Ks) meridians, maximum keratometric power (Kmax), keratometric cylinder, spherical power, regular astigmatism, asymmetry, higher-order irregularity (HOI) from the anterior and posterior surfaces, and the central and thinnest corneal thicknesses were evaluated. Also, anterior chamber depth (ACD), lens thickness, crystalline lens rise (CLR), and nasal and temporal angle opening distances at 500 µm from the scleral spur (AOD500) were assessed. Sex differences and age-related changes were analyzed. RESULTS: Women exhibited higher anterior Kf, Ks, and Kmax and lower posterior Kf, Ks, and Kmax than men. The ACD and nasal/temporal AOD500 were shorter in women than in men. The CLR was higher in women, whereas the lens thickness did not differ between the sexes, indicating a more anteriorly positioned lens in women. Age-related changes included increased anterior/posterior HOI, increased lens thickness and CLR resulting in decreased ACD and AOD500. CONCLUSION: This study reveals sex-related differences in corneal shape, anterior chamber conformation, and lens position, as well as age-related changes in tomographic parameters. ACD, CLR, nasal and temporal AOD500 showed significant sex differences in the 50-70 s, whereas lens thickness showed no difference.

2.
BMC Ophthalmol ; 24(1): 410, 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39300358

RESUMO

PURPOSE: To compare the biometric measurements obtained from the Pentacam AXL Wave, IOLMaster 700, and ANTERION and calculate the recommended intraocular lens power using the Barrett Formulae. METHODS: This was a retrospective cross-sectional study of patients who underwent biometry using the Pentacam AXL Wave, IOLMaster 700, and ANTERION. Flat keratometry (K1), steep keratometry (K2), anterior chamber depth (ACD), and axial length (AL) from each device were measured and compared. These parameters were used to calculate the recommended IOL powers using the Barrett formula. RESULTS: The study included 252 eyes of 153 patients. The IOLMaster had the highest acquisition rate among the two biometers. The Pentacam obtained the shortest mean AL, the IOLMaster measured the highest mean keratometry values, and the ANTERION measured the highest mean ACD. In terms of pairwise comparisons, keratometry and axial length were not significantly different between the Pentacam-IOLMaster and ANTERION-IOLMaster groups, while the rest of the pairwise comparisons were statistically significant. In nontoric and toric eyes, 35-45% of patients recommended the same sphere of IOL power. In another 30-40%, the Pentacam and ANTERION recommended an IOL power one step greater than that of the IOLMaster-derived data. 50% of the study population recommended the same toric-cylinder IOL power. CONCLUSIONS: The Pentacam AXL Wave, IOLMaster 700, and ANTERION can reliably provide data for IOL power calculations; however, these data are not interchangeable. In nontoric and toric eyes, 35-45% of cases recommended the same sphere IOL power, and in another 30-40%, the Pentacam and ANTERION recommended one-step higher IOL power than the IOLMaster-derived data. In targeting emmetropia, selecting the first plus IOL power is advisable when using the Pentacam and ANTERION to approximate the IOL power calculations recommended by the IOLMaster 700.


Assuntos
Biometria , Interferometria , Lentes Intraoculares , Tomografia de Coerência Óptica , Humanos , Estudos Retrospectivos , Estudos Transversais , Masculino , Biometria/instrumentação , Biometria/métodos , Feminino , Pessoa de Meia-Idade , Interferometria/instrumentação , Interferometria/métodos , Idoso , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/instrumentação , Comprimento Axial do Olho/diagnóstico por imagem , Adulto , Idoso de 80 Anos ou mais , Refração Ocular/fisiologia , Óptica e Fotônica , Câmara Anterior/diagnóstico por imagem
3.
J Med Life ; 17(6): 620-624, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39296439

RESUMO

Cataract surgery is one of the most successful surgical procedures, mainly due to the recent developments in surgical instruments and intraocular lens (IOL) measurements. Understanding the nature of axial length (AL) and keratometry readings (K) in patients with cataracts has significant implications for accurate postoperative IOL size selection. This study aimed to measure AL and K in patients undergoing cataract surgery in Saudi Arabia. This retrospective study included patients who underwent cataract surgery in Madinah, Saudi Arabia. The medical records of adult patients between May 2022 and May 2023 were reviewed, and those with a history of retinal detachment, refractive surgery, or trauma were excluded. The AL and K readings were obtained from the patient's IOL master results. A total of 691 eyes from 451 patients were included in the analysis. The mean age was 64.54 years old. Most of the patients were women (55%). The mean AL, K1, and K2 values were 23.27, 43.42, and 44.69, respectively. Linear regression analysis was used to measure the relationship between AL and K, revealing an inverse relationship in our findings. As AL increased by one unit, the mean K was estimated to decrease by 0.548, with a 95% confidence interval. Our results demonstrated an inverse relationship between AL and K, implying that when AL increases, K decreases, or the corneal curvature becomes flat. Further studies are needed to investigate the biomechanical mechanisms underlying this relationship.


Assuntos
Comprimento Axial do Olho , Extração de Catarata , Humanos , Arábia Saudita , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Comprimento Axial do Olho/patologia , Idoso , Córnea/patologia , Catarata/patologia , Adulto , Lentes Intraoculares , Idoso de 80 Anos ou mais
4.
Artigo em Inglês | MEDLINE | ID: mdl-39215849

RESUMO

PURPOSE: Corneal crosslinking (CXL) procedures are the treatment of choice in halting progressive corneal ectasia and preserving visual acuity due to keratoconus. Pulsed crosslinking (P-CXL) was developed using intermittent pulsing ultraviolet (UV) light to mitigate the depletion of oxygen levels that occurs with continuous UV exposure in standard crosslinking protocols (C-CXL). This study aimed to explore the use of P-CXL in the treatment of keratoconus and determine whether the availability of oxygen in P-CXL carries superior efficacy outcomes as an alternative to C-CXL modalities. METHODS: This review was undertaken in accordance with PRISMA guidelines. A search of several databases conducted with two separate reviewers resulted in 29 papers meeting inclusion criteria for the review, 14 selected for meta-analysis. Primary outcomes assessed by the included papers included maximum keratometry (Kmax), corrected and uncorrected distance visual acuity (CDVA, UDVA), and secondary outcomes included central corneal thickness (CCT), endothelial cell count and demarcation line. Statistical analyses were carried out on Review Manager 5.4 and the meta-analysis employed a random-effects model, which estimated the weighted effect size of raw means using inverse variance weights. RESULTS: At 12 months P-CXL showed statistically significant reductions in Kmax (-0.75 D; p < 0.001) and improvement in CDVA (-0.10 logMAR; p < 0.001) compared to baseline. The meta-analysis of comparative studies determined that mean differences in Kmax, CDVA, UDVA, Kmean and CCT after 12 months were not statistically significant between pulsed and continuous crosslinking groups. CONCLUSIONS: Overall, P-CXL is effective in improving visual acuity and keratometry outcomes in keratoconus. The meta-analysis did not show a statistically significant difference in Kmax and CDVA between P-CXL and C-CXL, indicating a non-inferiority of P-CXL. However, findings of the meta-analysis are limited by the fact that different energy levels and exposure times were used for P-CXL in comparison to C-CXL in some studies, making it unsuitable to determine whether the efficacy of CXL is improved by the use of pulsed light. KEY MESSAGES: What is Known • Pulsed crosslinking (P-CXL) uses intermittent UV light to prevent oxygen depletion when using higher energy protocols, unlike continuous UV exposure in standard continuous crosslinking (C-CXL). • This should theoretically enhance the efficacy of the treatment by maintaining higher oxygen levels that are crucial to the cross-linking process. • There are no systematic reviews or meta-analyses directly comparing the efficacy or safety of P-CXL to C-CXL. What is New • Meta-analysis revealed differences in keratometry between P-CXL and C-CXL groups with equivalent fluence (7.2 J/cm2) at 12 months were not statistically significant (Kmax -0.04 dioptres; p = 0.84). • Meta-analysis revealed differences in visual acuity between P-CXL and C-CXL groups with equivalent fluence (7.2 J/cm2) at 12 months were not statistically significant (CDVA -0.01 logMAR letters; p = 0.57). • The use of intermittent pulsing in higher energy CXL protocols renders statistically similar outcomes as continuous light exposure at equivalent fluence (7.2 J/cm2).

5.
Int Ophthalmol ; 44(1): 349, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39147902

RESUMO

PURPOSE: This retrospective study investigated the impact of corneal parameters on surgically induced astigmatism (SIA) in eyes with prior myopic correction undergoing cataract surgery. SETTING: Department of Ophthalmology, San Marino Hospital, San Marino, Republic of San Marino. DESIGN: This case-control study analyzed existing data retrospectively, without randomization or masking. METHODS: Eighty eyes divided in group 1 (40 eyes previous underwent refractive surgery for myopia) and group 2 ( 40 myopic eyes) that underwent cataract surgery with intraocular lens (IOL) implantation were included. SIA was calculated using values from the IOL Master Zeiss 700 and mean pupil power (MPP) derived from the CSO Sirius Topographer (based on 3 mm pupil size) with vectorial analysis from doctor Hill software. RESULTS: No significant difference in SIA was observed between eyes with prior myopic photorefractive keratectomy and the control group (p > 0.05). SIA calculations using the IOL Master and CSO Sirius Tomographer yielded similar results. There was no significant correlation between SIA and axial length, corneal curvature, peripheral corneal thickness, or anterior chamber depth (p > 0.05). However, an inverse correlation was found between SIA and horizontal corneal diameter (p < 0.05). CONCLUSIONS: Corneal parameters, such as axial length, corneal curvature, peripheral corneal thickness, and anterior chamber depth, showed no significant influence on SIA. The inverse correlation between SIA and horizontal corneal diameter in study group suggests potential influence of white-to-white distance on SIA. These findings highlight the importance of considering corneal parameters for optimizing surgical outcomes.


Assuntos
Astigmatismo , Córnea , Topografia da Córnea , Miopia , Humanos , Astigmatismo/etiologia , Astigmatismo/fisiopatologia , Astigmatismo/diagnóstico , Estudos Retrospectivos , Masculino , Feminino , Miopia/cirurgia , Miopia/fisiopatologia , Córnea/patologia , Córnea/cirurgia , Córnea/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos de Casos e Controles , Topografia da Córnea/métodos , Idoso , Extração de Catarata/efeitos adversos , Acuidade Visual , Implante de Lente Intraocular/efeitos adversos , Refração Ocular/fisiologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Facoemulsificação/efeitos adversos
6.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(10): 413-419, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39025231

RESUMO

OBJECTIVE: To compare the accuracy of Kane, Barrett Universal II, Haigis, and SRK-T formulas in eyes with average keratometry greater than 46 diopters (D). METHODS: A retrospective analysis was conducted on 101 eyes of 101 patients with average keratometry greater than 46 D. The absolute prediction error (EA) was obtained for each patient one month after surgery. The mean absolute prediction error (MEA), median absolute prediction error (MedEA) and the percentage of patients with absolute refractive error less than 0.25 D, 0.50 D, and 1.00 D were calculated for each formula analyzed. RESULTS: The Kane formula achieved the lowest MEA (0.53 ± 0.43) and the lowest MedEA (0.41), followed by Barrett Universal II (MEA: 0.56 ± 0.42, MedEA: 0.49), SRK-T (MEA: 0.59 ± 0.44, MedEA: 0.54), and Haigis (MEA: 0.77 ± 0.47, MedEA: 0.69), showing a significant difference in the results. It was also observed that the Kane formula was the most accurate, with the highest percentage of patients, with EA less than 0.25 D, 0.50 D, and 1.00 D (30.7%, 54.4%, and 86.1%, respectively), while the Haigis formula was the least accurate (12.9%, 33.7%, and 69.3%, respectively). CONCLUSION: In eyes with corneas having average keratometry greater than 46 D, the Kane formula proves to be a useful tool in intraocular lens (IOL) power calculation and demonstrates higher precision compared to the Barrett Universal II, SRK-T, and Haigis formulas.


Assuntos
Lentes Intraoculares , Humanos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Córnea/anatomia & histologia , Córnea/patologia , Óptica e Fotônica , Refração Ocular/fisiologia , Reprodutibilidade dos Testes , Biometria/métodos
7.
Artigo em Inglês | MEDLINE | ID: mdl-39060795

RESUMO

BACKGROUND: To describe the refractive outcomes of eyes with high regular corneal astigmatism undergoing age-related cataract surgery. METHODS: Astigmatic patients who underwent cataract surgery with implantation of high-power XY1AT HOYA® toric lenses (IOLs) (≥ T5) between March 2020 and June 2022 were included. Patients were divided into 2 groups based on the type of Total Corneal Astigmatism (TCA) used for the toric IOL calculation: group 1 = TCATK- 700 (TCA measured by the Iol Master 700®) and group 2 = TCAAK- 700 (TCA estimated from the anterior keratometry of the Iol Master 700® and using the Abulafia-Koch regression). The best-uncorrected (UDVA) and corrected (CDVA) distance visual acuity, subjective spherical equivalent (SSEq) and subjective residual cylinder (SRC) were assessed at 1 month. The predictability (centroid [CEPA] and mean absolute error in predicted astigmatism [MAEPA]) of the 2 TCA assessment methods was analyzed. RESULTS: 96 eyes of 74 patients were included. In the whole cohort, the UDVA was 0.14 ± 0.19 logMAR, the CDVA was 0.04 ± 0.07 logMAR. Postoperative SSEq was - 0.24 ± 0.53D. Postoperative SRC was - 0.48 ± 0.56D. The UDVA, SSEq and SRC did not significantly differ between groups. The MAEPA was significantly better with TCAAK-700 compared to TCATK-700: 0.58 ± 0.52D versus 0.65 ± 0.55D (p = 0.01). No significant difference was observed for the CEPA (p(x) = 0.09, p(y) = 0.19). CONCLUSIONS: XY1AT HOYA® toric IOLs are a very good alternative even in case of high toricity. Residual astigmatism predictability is high, it would be better with TCAAK- 700. This data should be confirmed with a larger sample of patients.

8.
Artigo em Inglês | MEDLINE | ID: mdl-39046518

RESUMO

BACKGROUND: To evaluate the repeatability and agreement of two different ocular biometers and Scheimpflug devices in keratoconus eyes. METHODS: This prospective, comparative trial took place at the University hospital, Goethe University, Frankfurt am Main, Germany. We included eyes with keratoconus, one eye per patient, randomly selected. Measurements were taken with Galilei G6 (Ziemer, Switzerland) and Pentacam AXL (Oculus, Germany), three consecutive measurements each. Repeatability and agreement were evaluated for simulated keratometry (simK), astigmatism (simA), maximum keratometry (KMax) and its axis, total keratometry (TCP), axial length (AL), anterior chamber depth (ACD), and thinnest pachymetry (TCT). RESULTS: Both devices showed an excellent repeatability with intra class correlation (ICC) of > 0.97 for all parameters. The 95% limits of repeatability (LoR95%) and agreement (LoA95%) were narrow for all parameters. The Galilei G6 had a narrower LoAR95% for TCT (2.1 µm vs. 4.6 µm), but a wider LoR95% for KMax (0.52D vs. 1.18D). No relevant difference was found for the other parameters. Agreement between the devices was good to moderate, especially for simK and TCP. CONCLUSIONS: Both devices show excellent repeatability with narrow LoR95% and high ICC for all parameters. The only relevant difference was found for KMax and TCT in favor of Pentacam AXL and Galilei G6, respectively. Agreement was good to moderate, and most parameters should not be considered interchangeable.

9.
Ophthalmol Ther ; 13(9): 2381-2391, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39020238

RESUMO

INTRODUCTION: The purpose of the study was to explore the possible correlations between the anterior segment parameters derived from anterior segment swept-source optical coherence tomography (AS-SS-OCT) with the surgically induced corneal astigmatism (CSIA) calculated from total keratometry (TK) measured by AS-SS-OCT. METHODS: Seventy-one eyes of 67 patients with age-related cataract who underwent phacoemulsification combined with intraocular lens implantation with 2.2-mm incision were included. The CSIA values were calculated from anterior keratometry (CSIAKant) and TK (CSIATK) measured by AS-SS-OCT, respectively. Hotelling's T2 test was used to evaluate the difference. The correlation of CSIA with various parameters derived from AS-SS-OCT was tested with the Spearman correlation coefficient. RESULTS: The centroid of CSIAKant and of CSIATK were 0.31 ± 0.55 D @ 54° and 0.41 ± 0.59 D @ 51°, with no significant difference (F = 1.283, p = 0.281, Hotelling's T2). The mean absolute CSIAKant and CSIATK were 0.58 ± 0.24 D and 0.65 ± 0.28 D. Spearman test showed that the magnitude of CSIAKant was negatively correlated with preoperative peripheral corneal thickness (PCT, p = 0.045) and the magnitude of anterior keratometry (p = 0.044). The magnitude of CSIATK was negatively correlated with preoperative central corneal thickness (CCT, p = 0.003) and preoperative PCT (p = 0.015). CONCLUSIONS: The increased thickness of the peripheral cornea is correlated with the decrease in the magnitude of the CSIA. The correlation we identified between the corneal thickness and the CSIA indicated that certain preoperative parameters should be considered for the prediction of CSIA for a more precise refractive outcome.

10.
Ophthalmol Ther ; 13(7): 2023-2035, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38824471

RESUMO

INTRODUCTION: The study aims to demonstrate and estimate the prevalence of clinical corneal ectasia and keratoconus (KC) in patients with relatively low keratometry (low-K KC). METHODS: In a retrospective, analytical, and non-interventionist study, one eye was randomly selected from 1054 patients from the original Tomographic Biomechanical Index (TBIv1) study and the external validation (from Rio de Janeiro, Brazil, and Milan, Italy clinics). Patients were stratified into three groups. Group 1 included 736 normal patients, and groups 2 and 3 included 318 patients with clinical KC in both eyes, divided into low-K KC (90 patients) and high-K KC (228 patients), respectively. All patients underwent a comprehensive ophthalmological evaluation along with Pentacam and Corvis ST (Oculus, Wetzlar, Germany) examinations. Cases with maximum mean zone 3 mm keratometry (Kmax zone mean 3 mm) lower than 47.6 diopters (D) were considered as low-keratometry keratoconus, and cases with Kmax zone mean 3 mm higher than 47.6 D were regarded as high-keratometry keratoconus. RESULTS: Ninety (28.30%) of the 318 KC group presented ectasia with low-keratometric values (low-Kmax). The average age in the normal group was 39.28 years (range 6.99-90.12), in the low-Kmax KC group it was 37.49 (range 13.35-78.45), and in the high-Kmax KC group it was 34.22 years (range 12.7-80.34). Mean and SD values and median (range), respectively, of some corneal tomographic and biomechanical parameters evaluated from the low-Kmax KC group were as follows: Belin-Ambrósio enhanced ectasia display (BAD-D) 3.79 ± 1.62 and 3.66 (0.83-9.73); Pentacam random forest index (PRFI) 0.78 ± 0.25 and 0.91 (0.05-1); corneal biomechanical index (CBI) 0.58 ± 0.43 and 0.75 (0-1); TBI 0.93 ± 0.17 and 1 (0.35-1); and stiffness parameter at A1 (SP-A1) 86.16 ± 19.62 and 86.05 (42.94-141.66). CONCLUSION: Relatively low keratometry, with a Kmax lower than 47.6 D, can occur in up to 28.30% of clinical keratoconus. These cases have a less severe presentation of the disease. Future studies involving larger populations and prospective designs are necessary to confirm the prevalence of keratoconus with low keratometry and define prognostic factors in such cases.

11.
Bioengineering (Basel) ; 11(6)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38927833

RESUMO

Cataracts are characterized by the crystalline lens of the eye becoming cloudy, and dry eye disease (DED) is a multifactorial disease in which the homeostasis of the tear film is lost. As the prevalence of both diseases increases with age, there is a high prevalence of DED among patients who are candidates for cataract surgery. In recent years, cataract surgery has evolved from vision restoration surgery to refractive surgery. To achieve good surgical outcomes, it is necessary to minimize postoperative refractive error in intraocular lens (IOL) power calculation, which requires accurate preoperative keratometry measurements. A stable tear film is important for the accuracy and reproducibility of keratometry measurements, and DED may have a deleterious effect. In this study, original articles that focused primarily on findings related to this topic were evaluated. A systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Although appropriate DED diagnoses were not presented in the articles evaluated in this review, it was confirmed that the clinical signs of DED, particularly the shortening of the tear film break-up time (TBUT), negatively impact IOL power calculations. Improvement in these clinical signs might mitigate the negative effects on these calculations.

12.
Int Ophthalmol ; 44(1): 237, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38902457

RESUMO

PURPOSE: Calculating the intraocular lens (IOL) in patients after corneal refractive surgery presents a challenge. Because an overestimation of corneal power in cases undergone this surgery leading to a subsequent under-correction of IOL power. However, recent advancements in technology have eliable measurement of total corneal power. The aim of this research was to assess the agreement in simulated keratometry (SimK) and total keratometry (TK) values between IOLMaster 700 and Pentacam AXL. METHODS: The study involved 99 patients (99 eyes) undergone small incision lenticule extraction (SMILE) surgery. Each patient underwent scans using IOL Master 700 and Pentacam AXL. The following parameters were recorded: SimK1, SimK2, Total K1 (TK1), and Total K2 (TK2) for IOLMaster 700; and SimK1, SimK2, True Net Power (TNP) K1, TNPK2, Total Corneal Refractive Power (TCRP) K1, and TCRP K2 for Pentacam AXL. Agreement between the two devices was evaluated using Bland-Altman plot, while paired t-test was utilized to compare any differences in the same parameter by both instruments. RESULTS: The results revealed a strong correlation between the two devices.Noticeable comparability was identified for all SimK variables. However, there were noticeable differences in TK measurements as well as TK1-TNPK1, TK2-TNP K2, TK1-TCRP K1, and TK2-TCRP K2 parameters when comparing the two devices. The IOLMaster 700 consistently measured steeper values than the Pentacam AXL, with significant and clinically relevant differences of 1.34, 1.37, 0.87, and 0.95 diopters, respectively. CONCLUSION: While there was a noticeable correlation between the IOLMaster 700 and Pentacam AXL in SimK measurements, a marked difference was noted in TK values. The two devices cannot be used interchangeably when quantifying TK values.


Assuntos
Córnea , Topografia da Córnea , Miopia , Refração Ocular , Humanos , Masculino , Feminino , Adulto , Córnea/cirurgia , Córnea/diagnóstico por imagem , Córnea/patologia , Refração Ocular/fisiologia , Topografia da Córnea/métodos , Miopia/cirurgia , Miopia/diagnóstico , Pessoa de Meia-Idade , Adulto Jovem , Lentes Intraoculares , Biometria/métodos , Biometria/instrumentação , Estudos Prospectivos , Reprodutibilidade dos Testes , Acuidade Visual , Cirurgia da Córnea a Laser/métodos
13.
Clin Exp Ophthalmol ; 52(6): 627-638, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38741026

RESUMO

BACKGROUND: To compare results from different corneal astigmatism measurement instruments; to reconstruct corneal astigmatism from the postimplantation spectacle refraction and toric intraocular lens (IOL) power; and to derive models for mapping measured corneal astigmatism to reconstructed corneal astigmatism. METHODS: Retrospective single centre study involving 150 eyes treated with a toric IOL (Alcon SN6AT, DFT or TFNT). Measurements included IOLMaster 700 keratometry (IOLMK) and total keratometry (IOLMTK), Pentacam keratometry (PK) and total corneal refractive power in 3 and 4 mm zones (PTCRP3 and PTCRP4), and Aladdin keratometry (AK). Regression-based models mapping the measured C0 and C45 components (Alpin's method) to reconstructed corneal astigmatism were derived. RESULTS: Mean C0 components were 0.50/0.59/0.51 dioptres (D) for IOLMK/PK/AK; 0.2/0.26/0.31 D for IOLMTK/PTCRP3/PTCRP4; and 0.26 D for reconstructed corneal astigmatism. All corresponding C45 components ranged around 0. The prediction models had main diagonal elements lower than 1 with some crosstalk between C0 and C45 (nonzero off-diagonal elements). Root-mean-squared residuals were 0.44/0.45/0.48/0.51/0.50/0.47 D for IOLMK/IOLMTK/PK/PTCRP3/PTCRP4/AK. CONCLUSIONS: Results from the different modalities are not consistent. On average IOLMTK/PTCRP3/PTCRP4 match reconstructed corneal astigmatism, whereas IOLMK/PK/AK show systematic C0 offsets of around 0.25 D. IOLMTK/PTCRP3/PTCRP4. Prediction models can reduce but not fully eliminate residual astigmatism after toric IOL implantation.


Assuntos
Astigmatismo , Biometria , Córnea , Topografia da Córnea , Implante de Lente Intraocular , Refração Ocular , Humanos , Astigmatismo/fisiopatologia , Astigmatismo/diagnóstico , Astigmatismo/cirurgia , Estudos Retrospectivos , Masculino , Biometria/métodos , Refração Ocular/fisiologia , Feminino , Córnea/diagnóstico por imagem , Córnea/patologia , Idoso , Pessoa de Meia-Idade , Topografia da Córnea/métodos , Lentes Intraoculares , Segmento Anterior do Olho/diagnóstico por imagem , Acuidade Visual/fisiologia , Idoso de 80 Anos ou mais , Facoemulsificação , Adulto
14.
J Clin Med ; 13(9)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38731065

RESUMO

Background: This study aimed to compare keratometry and anterior chamber depth (ACD) changes after XEN implantation in primary open-angle glaucoma (POAG) cases over a 3-month follow-up period. Methods: Twenty patients with POAG who underwent XEN63 implantation, either standalone or combined with cataract surgery, were included. Preoperative data, including best-corrected visual acuity (BCVA), refraction, gonioscopy, ophthalmoscopy, intraocular pressure (IOP) evaluation, and axial length, were collected. Corneal topography and ACD measurements were assessed preoperatively and at postoperative days 1, 7, 15, 30, 60, and 90. Each patient's eye that underwent XEN surgery was included in the study group, with the fellow eye serving as a control. Results: In the study group, there was a significant decrease in IOP after XEN stent implantation at all investigated time intervals (p < 0.05). However, changes in mean ACD did not show statistically significant differences at any follow-up examination in both the study and control groups. Additionally, keratometry readings revealed no significant changes in total astigmatism or steep keratometry values in either group. Conclusions: XEN implantation in POAG cases resulted in a significant decrease in IOP over the 3-month follow-up period. However, there were no significant changes observed in mean ACD or keratometry readings, indicating stability in these parameters post-XEN implantation. These findings suggest that XEN implantation may be an effective option for IOP reduction without affecting corneal curvature or ACD in POAG patients.

15.
Cont Lens Anterior Eye ; 47(3): 102164, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38594154

RESUMO

PURPOSE: To determine the changes in keratometry measurements and refraction in patients having the thermo-mechanical periorbital skin treatment, Tixel®, to treat dry eye disease (DED). METHODS: A multi-centre, prospective, non-masked study was conducted. DED patients were recruited in 3 international centres and were evaluated in 5 visits separated by an interval of 2 weeks except for the last visit which took place after 18 weeks from visit 1. The same clinical examination was performed at all visits: OSDI questionnaire, tear stability, keratometry, best corrected visual acuity and refraction. Tixel® treatment was applied at the first 3 visits. RESULTS: 89 participants (24 males/65 females; mean age: 55.0 ± 14.2 years) were included: 20 presented moderate DED symptoms and 69 severe DED symptoms. Significant differences were found for the spherocylindrical refraction (vector analysis) between visit 1 and visits 2 and 3. Following cumulative analysis, 11.86 % and 16.94 % of participants had more than 0.5 dioptre (D) change in mean keratometry and keratometric astigmatism, respectively, at 3 months post-treatment. A total of 5.40 % had a sphere and cylinder change greater than 0.50D and 16.21 % had the axis changed more than 10 degrees (vector analysis). These changes were particularly significant in patients with severe DED symptoms. CONCLUSIONS: Keratometry readings and refraction can change following thermo-mechanical skin treatment for DED, especially in those patients with severe DED symptoms. This should be considered as potential errors in intraocular lens calculations may be induced.


Assuntos
Extração de Catarata , Síndromes do Olho Seco , Refração Ocular , Acuidade Visual , Humanos , Síndromes do Olho Seco/fisiopatologia , Síndromes do Olho Seco/terapia , Síndromes do Olho Seco/diagnóstico , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Prospectivos , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Idoso , Adulto , Córnea/fisiopatologia
16.
Eur J Ophthalmol ; 34(4): 973-979, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38632934

RESUMO

PURPOSE: To establish new criteria for the progression of keratoconus, taking into account a Pentacam HR (high resolution) tomographers repeatability limit. METHODS: This is a retrospective observational study, including 224 eyes in 154 patients diagnosed with keratoconus and patients treated with crosslinking, with a follow-up of at least one year, in which the new progression score of the Cruces University Hospital for keratoconus progression was analyzed. This score takes into account: maximum keratometry, thinnest corneal thickness, maximum posterior elevation, vertical coma and RMS of high order aberrations, all based on the tomographer repeatability limit. The effectiveness or not of crosslinking was determined. RESULTS: The Receiver Operating Characteristics (ROC) curves obtained in our validation met the criteria by being far from the reference diagonal. Moreover, young patients are more likely to have keratoconus that progresses, and the percentage of patients that showed progression was 14.3% of the eyes studied, with the most advanced keratoconus showing the least progression. Taking into account the new progression score of the Cruces Hospital, we would have indicated crosslinking in 2 eyes only and we observed that none progressed one year after treatment. CONCLUSIONS: The the new progression score of the Cruces University Hospital is a method based on the real repeatability limit for keratoconic eyes. Moreover, it is easy to interpret and can be implemented with Pentacam software. It provides a numerical value that evaluates both the anterior and posterior surfaces of the cornea and corneal aberrations in the evolution of keratoconus.


Assuntos
Córnea , Topografia da Córnea , Progressão da Doença , Ceratocone , Curva ROC , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Estudos Retrospectivos , Feminino , Masculino , Adulto , Topografia da Córnea/métodos , Adulto Jovem , Córnea/patologia , Córnea/diagnóstico por imagem , Seguimentos , Reagentes de Ligações Cruzadas/uso terapêutico , Acuidade Visual/fisiologia , Adolescente , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Colágeno/metabolismo , Fotoquimioterapia/métodos , Pessoa de Meia-Idade
17.
BMC Ophthalmol ; 24(1): 182, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649848

RESUMO

BACKGROUND: The precision of anterior segment biometric measurements in eyes has become increasingly important in refractive surgery. The purpose of this study is to assess the repeatability of the automatic measurements provided by a new spectral-domain optical coherence tomograph (SD-OCT)/Placido topographer (MS-39, CSO) and its agreement with a swept-source OCT (SS-OCT) biometer (CASIA SS-1000, Tomey) in patients with myopia. METHODS: The right eye of 235 subjects was scanned 3 times with both devices. The evaluated parameters included central corneal radius of the steep meridian, central corneal radius of the flat meridian, mean central corneal radius, thinnest corneal thickness, central corneal thickness, anterior chamber depth, corneal volume and diameter. The intraobserver repeatability of the MS-39 measurements was calculated using intraclass correlation coefficient (ICC), within subject standard deviation, coefficient of repeatability, coefficient of variation and repeated-measures analysis of variance of the 3 repeated measurements. The agreement between the two devices was evaluated by 95% limits of agreement (LoA). RESULTS: The majority of the parameters acquired from MS-39 showed high repeatability. The repeatability of corneal diameter was slightly lower than the other measurements, although the ICC remained high. Agreement with the CASIA SS-1000 was good, indicated by the Bland-Altman plots with narrow 95% LoA values for all parameters assessed. CONCLUSIONS: The high repeatability of automatic measurements by the new device supports its clinical application in eyes with myopia, and the good agreement between the two devices indicates they could be used interchangeably for the parameters evaluated.


Assuntos
Segmento Anterior do Olho , Córnea , Topografia da Córnea , Miopia , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Adulto , Miopia/diagnóstico , Miopia/fisiopatologia , Topografia da Córnea/métodos , Topografia da Córnea/instrumentação , Reprodutibilidade dos Testes , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia , Adulto Jovem , Córnea/diagnóstico por imagem , Córnea/patologia , Pessoa de Meia-Idade , Biometria/métodos , Adolescente , Estudos Prospectivos
18.
Graefes Arch Clin Exp Ophthalmol ; 262(8): 2533-2539, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38456928

RESUMO

PURPOSE: This study aimed to estimate the corneal keratometric index in the eyes of cataract surgery patients who received zero-power intraocular lenses (IOLs). METHODOLOGY: This retrospective study analyzed postoperative equivalent spherical refraction and axial length, mean anterior curvature radius and aqueous humor refractive index to calculate the theoretical corneal keratometric index value (nk). Data was collected from 2 centers located in France and Germany. RESULTS: Thirty-six eyes were analyzed. The results revealed a mean corneal keratometric index of 1.329 ± 0.005 for traditional axial length (AL) and 1.331 ± 0.005 for Cooke modified axial length (CMAL). Results ranged from minimum values of 1.318/1.320 to maximum values of 1.340/1.340. CONCLUSION: The corneal keratometric index is a crucial parameter for ophthalmic procedures and calculations, particularly for IOL power calculation. Notably, the estimated corneal keratometric index value of 1.329/1.331 in this study is lower than the commonly used 1.3375 index. These findings align with recent research demonstrating that the theoretical corneal keratometric index should be approximately 1.329 using traditional AL and 1.331 using CMAL, based on the ratio between the mean anterior and posterior corneal curvature radii (1.22).


Assuntos
Extração de Catarata , Córnea , Lentes Intraoculares , Refração Ocular , Humanos , Estudos Retrospectivos , Feminino , Masculino , Refração Ocular/fisiologia , Idoso , Pessoa de Meia-Idade , Comprimento Axial do Olho/patologia , Acuidade Visual/fisiologia , Idoso de 80 Anos ou mais , Topografia da Córnea/métodos , Implante de Lente Intraocular , Desenho de Prótese , Seguimentos , Biometria/métodos
19.
BMC Ophthalmol ; 24(1): 143, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38549060

RESUMO

AIM: To investigate the correlation of angles α and κ with the refractive and biological parameters in children. METHODS: This case-series study included 438 eyes of 219 children (males/females = 105/114, age: 3-15 years). Ocular biometric parameters, including axial length, corneal radius of curvature (CR), white-to-white distance (WTW), angle κ and angle α, were measured using IOL Master 700; auto-refraction were assessed under cycloplegia. The eyes were assigned to different groups based on CR, WTW, and gender to compare the angles α and κ, and analyze the correlations between the differences of biological parameters on angles α and κ. RESULTS: The means of axial length, CR, WTW, angle α, and angle κ were 23.24 ± 1.14 mm, 7.79 ± 0.27 mm, 11.68 ± 0.41 mm, 0.45 ± 0.25 mm, and 0.27 ± 0.22 mm, respectively. Angle α was correlated with CR and WTW (fixed effect coefficient [FEC] = 0.237, p = 0.015; FEC = -0.109, p = 0.003; respectively), and angle κ also correlated with CR and WTW (FEC = 0.271, p = 0.003; FEC = -0.147, p < 0.001, respectively). Comparing subgroups, the large CR and small WTW group had larger angles α (0.49 ± 0.27 vs. 0.41 ± 0.21, p < 0.001; 0.46 ± 0.27 vs. 0.44 ± 0.21, p < 0.05, respectively) and κ (0.29 ± 0.25 vs. 0.24 ± 0.15, p < 0.01; 0.29 ± 0.25 vs. 0.26 ± 0.19, p < 0.05, respectively). The differences in interocular angles α and κ showed correlation with interocular WTW (r = - 0.255, p < 0.001; r = - 0.385, p < 0.001). Eyes with smaller WTW tended to have larger angle κ (0.28 ± 0.27 vs. 0.25 ± 0.15, p < 0.05). CONCLUSION: The size of angle α/κ may be correlated to CR and WTW, and a larger WTW eye may suggest a smaller angle κ compared with the fellow eye.


Assuntos
Presbiopia , Refração Ocular , Criança , Humanos , Feminino , Masculino , Pré-Escolar , Adolescente , Testes Visuais , Córnea , Biometria , Comprimento Axial do Olho
20.
Vestn Oftalmol ; 140(1): 5-10, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38450460

RESUMO

Marfan syndrome (MS) is an orphan hereditary connective tissue disease associated with a mutation in the FBN1 gene, which pathological manifestations are characterized by polysystemic involvement. The fibrillin-1 protein is an integral component of the sclera and cornea of the eye, and in MS its structure is distrubed. PURPOSE: This study assesses potential structural and functional changes in the cornea and sclera of a patient with MS. MATERIAL AND METHODS: Two groups were formed, comparable in the axial length of the eye and age: the main group - 19 patients (38 eyes) with a verified diagnosis of MS, and the control group - 24 patients (48 eyes) with myopia of varying degrees. The results obtained from MS patients were analyzed depending on the absence or presence of ectopia lentis. In addition to measuring the basic ophthalmological parameters (refraction, axial length, visual acuity), topographic keratometry, anterior segment optical coherence tomography, and ocular response analyzer were used for structural and functional assessment of the cornea and sclera. RESULTS: In MS there was a statistically significant increase in the radius of curvature and a decrease in corneal refraction in the central zone compared to the control group. There were no significant differences in central corneal thickness, but there was a significant decrease in the thickness of the sclera in the limbal zone compared to the control group. There were no statistically significant changes in corneal hysteresis and corneal resistance factor in MS. CONCLUSION: This study confirmed the previously obtained data on the tendency of the optical power to reliably decrease in MS (flattening of the cornea). This symptom can be considered as a compensatory factor affecting clinical refraction, while the decrease in the thickness of the sclera - as the main reason for aaxial length elongation in MS. There were no clear patterns of dependence of the changes in the cornea and sclera analyzed in this study on the presence or absence of ectopia lentis. Changes in the lens, perhaps, should be regarded only as one of the potential components of the ocular symptom complex in MS.


Assuntos
Ectopia do Cristalino , Síndrome de Marfan , Humanos , Síndrome de Marfan/complicações , Síndrome de Marfan/diagnóstico , Ectopia do Cristalino/diagnóstico , Ectopia do Cristalino/etiologia , Córnea/diagnóstico por imagem , Esclera/diagnóstico por imagem , Refração Ocular