EFSA J ; 20(9): e07524, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36177388

RESUMO

Following a request from the European Commission, the EFSA Panel on Contaminants in the Food Chain (CONTAM) assessed a decontamination process of fish oils and vegetable oils and fats to reduce the concentrations of dioxins (polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, abbreviated together as PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) by adsorption to activated carbon. All feed decontamination processes must comply with the acceptability criteria specified in the Commission Regulation (EU) 2015/786. Data provided by the feed food business operator (FBO) were assessed for the efficacy of the process and to demonstrate that the process did not adversely affect the characteristics and properties of the product. The limited information provided, in particular on the analysis of the samples before and after decontamination, did not allow the CONTAM Panel to conclude whether or not the proposed decontamination process is effective in reducing PCDD/Fs and DL-PCBs in the fish- and vegetable oils and fats. Although there is no evidence from the data provided that the decontamination process leads to detrimental changes in the nutritional composition of the fish- and vegetable oils, it is possible that the process could deplete some beneficial constituents (e.g. vitamins). Taken together, it was not possible for the CONTAM Panel to conclude that the decontamination process as proposed by the FBO is compliant with the acceptability criteria provided for in Commission Regulation (EU) 2015/786 of 19 May 2015.

2.
Int J Environ Sci Technol (Tehran) ; 19(2): 785-796, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34548875

RESUMO

Urban air pollution and exposure-related health impacts are being noticed and discussed very intensely in India. On the other hand, source-specific control is the primary focus for policymakers; however, diverse and complex sources make it difficult to immediately see the action and consequent impacts on better air quality. Many cities across the world have witnessed high air pollution levels at traffic junctions, more so in all Indian cities. Site-specific air pollution reduction can be a promising solution for managing the pollution level at highly polluted locations. CSIR-National Environmental Engineering Research Institute, India, has designed and developed Wind Augmentation and purifYing Unit (WAYU) to remove particulate and gaseous pollutants from urban hot spots such as traffic locations. In the present study, the authors attempted to evaluate the performance of two different designs of WAYU for the removal of particulate matters from polluted air at different traffic locations in Delhi City, the national capital territory of India. The performance analyses show that the current design of WAYU removes PM10 and PM2.5 concentrations in the range of 34-49% and 19-25%, respectively from the inlet air. The total PM collected from all WAYU devices was 34.19 kg from 120,557 operating hours' at all the sampling sites. The PM removal rate depends on the size-segregated particulate matter pollution load in the ambient air. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13762-021-03641-3.

3.
EFSA J ; 16(2): e05174, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32625809

RESUMO

Following a request from the European Commission, the EFSA Panel on Contaminants in the Food Chain (CONTAM) provided a scientific opinion on the assessment of a decontamination process of fish meal. It consisted of extraction of the fish oil, filtration and adsorption with activated carbon, and replacement with decontaminated fish oil in order to reduce the amount of dioxins (polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs)), and dioxin-like (DL-) and non-dioxin-like (NDL-) polychlorinated biphenyls (PCBs). All feed decontamination processes must comply with the acceptability criteria specified in the Commission Regulation (EU) 2015/786. Data provided by the feed business operator were assessed for efficacy of the process and to demonstrate that the process did not adversely affect the characteristics and the nature of the product. The process was effective in removing PCDD/Fs (97%) and DL- and NDL-PCBs (93%). The fish meal produced complied with EU regulations for these contaminants. The Panel considered that the reference to information available in published literature was a pragmatic approach to demonstrate that the replacement of fish oil and the use of activated carbon to adsorb these contaminants does not lead to any detrimental changes in the nature of the fish meal. However, it was noted that the process could deplete some beneficial constituents (e.g. oil-soluble vitamins). Information was provided to demonstrate the safe disposal of the waste material. The CONTAM Panel concluded that on the basis of the information submitted by the feed business operator the proposed decontamination process to remove dioxins (PCDD/Fs) and PCBs from the fish meal by oil extraction followed by replacement with decontaminated fish oil, was compliant with the acceptability criteria provided for in Commission Regulation (EU) 2015/786 of 19 May 2015.

4.
EFSA J ; 15(12): e05081, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32625374

RESUMO

Following a request from the European Commission, the EFSA Panel on Contaminants in the Food Chain (CONTAM) provided a scientific opinion on the assessment of decontamination processes involving the adsorption with activated carbon and physical filtration of fish oil in order to reduce the amount of dioxins (polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs)) and dioxin-like polychlorinated biphenyls (DL-PCBs). All feed decontamination processes must comply with the acceptability criteria specified in the Commission Regulation (EU) 2015/786. Two feed business operators provided data on their respective decontamination processes, which were assessed in terms of the efficacy of the process and the absence of adverse effects in the nature and characteristics of the product after decontamination. The processes proved to be able to remove PCDD/Fs (82-95%) and DL-PCBs (26-45%) from the fish oil, depending on the process used by the business operator. Given that the level of contamination is within the range of the tested untreated fish oil, it is possible to meet EU requirements for these contaminants after decontamination. The CONTAM Panel considered both the evidence provided by one of the business operators and information in the available literature to conclude that the proposed processes do not lead to any detrimental changes in the nature of the fish oil. However, the process can deplete some beneficial constituents (e.g. vitamins). Information was provided to demonstrate the safe disposal of the waste material. The CONTAM Panel concluded that, on the basis of the information submitted by the feed business operators, the proposed decontamination processes to remove dioxins (PCDD/Fs) and DL-PCBs from the fish oil by means of activated carbon and physical filtration were compliant with the acceptability criteria provided for in Commission Regulation (EU) 2015/786 of 19 May 2015.

5.
EFSA J ; 15(7): e04961, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32625605

RESUMO

Following a request from the European Commission, the EFSA Panel on Contaminants in the Food Chain (CONTAM) provided a scientific opinion on the assessment of a decontamination process consisting in the adsorption with activated carbon and physical filtration of fish oil in order to reduce the amount of dioxins (polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs)) and dioxin-like polychlorinated biphenyls (DL-PCBs). All feed decontamination processes must comply with the acceptability criteria specified in the Commission Regulation (EU) 2015/786. The data provided by the feed business operator were assessed with respect to the efficacy of the process and on information demonstrating that the process does not adversely affect the characteristics and the nature of the product. As described in scientific literature, the process was effective in removing PCDD/Fs (84%) and DL-PCBs (55%), and therefore, it is possible to meet the current EU requirements with respect to these contaminants, assuming that the level of contamination of untreated fish oil was within the range of the tested batches. The Panel considered that the reference to information available in published literature was a pragmatic approach to demonstrate that the use of activated carbon adsorption does not lead to any detrimental changes in the nature of the fish oil; however, it was noted that the process could deplete some beneficial constituents (e.g. vitamins). Information was provided to demonstrate the safe disposal of the waste material. The CONTAM Panel concluded that on the basis of the information submitted by the feed business operator the proposed decontamination process to remove dioxins (PCDD/Fs) and DL-PCBs from the fish oil by means of physical filtration with activated carbon, was compliant with the acceptability criteria provided for in Commission Regulation (EU) 2015/786 of 19 May 2015.