Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.528
Filtrar
1.
Sleep Med ; 123: 7-21, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39226674

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) is associated with the impairment of a range of cognitive functions. Whether treatment with continuous positive airway pressure (CPAP) improves these cognitive functions is still a matter of debate. METHODS: We performed a systematic review and meta-analysis of randomized controlled trials (RCTs) that included OSA patients (apnea hypopnea index, AHI >10/h), naive to CPAP treatment, with a cognitive assessment before and after CPAP initiation. We compared CPAP versus sham-CPAP or placebo tablet or dietary rules or no treatment. This systematic review and meta-analysis were registered in PROSPERO (ID CRD42021275214). RESULTS: Eleven RCTs encompassing 923 OSA patients were included. For most of them, CPAP initiation was ≤3 months. A significant post-treatment improvement was found for the Trail Making Test part B (TMT-B; SMD = -0.93, 95 % CI = [-1.60, -0.25], Z = -2.70, p = 0.007), but not for the other neuropsychological assessments. No global effects on other cognitive domains (information processing speed, executive functions, working memory) were found. CONCLUSION: The significant improvement in the TMT-B supports a short-term enhancement in cognitive flexibility with CPAP treatment. Further studies that take into account OSA comorbidities, cognitive profiles, a more diverse range of cognition assessments and include long-term evaluations are needed.


Assuntos
Cognição , Pressão Positiva Contínua nas Vias Aéreas , Apneia Obstrutiva do Sono , Humanos , Pressão Positiva Contínua nas Vias Aéreas/métodos , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/psicologia , Cognição/fisiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Testes Neuropsicológicos/estatística & dados numéricos , Adulto
2.
Sleep ; 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39319690

RESUMO

STUDY OBJECTIVES: To investigate the predictors of persistent driving risk related to sleepiness in patients with obstructive sleep apnea syndrome treated by continuous positive airway pressure. METHODS: Longitudinal analysis of a prospective national database including 5,308 patients with obstructive sleep apnea syndrome and an indication of continuous positive airway pressure. Near-misses related to sleepiness, accidents related to sleepiness, and sleepiness at the wheel were assessed before initiation and after ≥ 90 days of treatment. Multivariable associations with the cumulative incidence of near-misses and accidents under treatment were calculated using Cox models adjusted for age, sex, obesity, sleep duration, sleepiness at the wheel, accidents/near-misses history, depressive symptoms, residual apnea-hypopnea index, and adherence to treatment. RESULTS: Residual sleepiness at the wheel under treatment was associated with eight-fold higher incidence of near-misses related to sleepiness (HR=8.63 [6.08-12.2]) and five-fold higher incidence of accidents related to sleepiness (HR=5.24 [2.81-9.78]). Adherence ≤4h/night was also a significant predictor of persistent driving risk (HR=1.74 [1.12-2.71] for near-misses and HR=3.20 [1.37-7.49] for accidents). CONCLUSIONS: Residual sleepiness at the wheel and treatment-adherence ≤4h/night are easy-to assess markers to detect persistent driving risk during the follow-up evaluations of patients under treatment. Health professionals, but also policy makers, should be aware of the crucial importance to systematically evaluate these elements during the follow-up evaluations of the patients with obstructive sleep apnea syndrome treated by continuous positive airway pressure to better evaluate their driving risk.

3.
J Clin Sleep Med ; 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39297538

RESUMO

STUDY OBJECTIVES: Patients with obstructive sleep apnea (OSA) often require the use of a continuous positive airway pressure (CPAP) machine. However, some patients experience issues using CPAP after receiving a dacryocystorhinostomy (DCR) for epiphora. This review aims to assess these complications and the potential interventions. METHODS: A systematic literature search was conducted in March 2023 with the PubMed, EMBASE, Web of Science, and Scopus databases. Since most of the studies were case reports and lacked quantitative results, a narrative review was done. RESULTS: Fourteen studies were included for review, representing 49 patients. During nightly CPAP use, 77.6% (38/49) of patients experienced air regurgitation onto the ocular surface via the tear drainage passage constructed by DCR. The interventions attempted could be categorized into (a) CPAP changes or (b) ophthalmic management. CPAP changes included changing the CPAP mask (successful in 5/6 patients), modifying the pressure or incorporating heated humidifier tubing (2/8 successes), changing the ventilation mode (1/3 successes), and switching to a CPAP alternative (1/2 successes). Ophthalmic management included eye plugs (3/3 successes), eye lubricants (2/6 successes), an eye patch (1/2 successes), and removal of the Lester Jones tube placed during DCR (1/1 successes). After trying these interventions, 36.7% (18/49) of patients continued to experience symptoms and opted to discontinue CPAP therapy. CONCLUSIONS: CPAP related issues after DCR are common and can be difficult to treat. There are a variety of techniques to improve CPAP use and adherence after DCR.

4.
Sleep Breath ; 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39240486

RESUMO

PURPOSE: Endocan is a biomarker of endothelial dysfunction, which is a precursor to cardiovascular disease. Obstructive sleep apnoea (OSA) is associated with elevated endocan levels but the effects of treatment on endocan levels in OSA are not fully established. We aimed to determine whether endocan levels could be detected by immunoassay and to determine the effect of supplemental oxygen during continuous positive airway pressure (CPAP) withdrawal on circulating endocan levels. METHODS: We conducted an exploratory analysis from a randomised controlled crossover study which included participants with OSA. Participants stopped their CPAP therapy and were randomised to receive either supplemental oxygen or sham for 14 nights before crossing over. Supplemental oxygen blocked the rise in blood pressure seen in the sham group. We analysed plasma endocan levels by immunoassay at baseline and after 14 nights of intervention in both groups. RESULTS: Twenty-five participants were included, with a total of 100 samples. Endocan levels were detectable at all time points in 22 participants (88%), and in 93 (93%) samples. Supplemental oxygen had no effect on endocan levels compared to sham (+ 0.52 ng/ml, 95%CI -0.21 to + 1.25, p = 0.16), and there was no significant difference in endocan levels from baseline to follow-up in either the sham (-0.30 ng/ml, 95%CI -0.89 to + 0.30, p = 0.31) or supplemental oxygen (+ 0.22 ng/ml, 95%CI 0.00 to + 0.44, p = 0.05) arm. CONCLUSIONS: We have shown that endocan levels are detectable before and after CPAP withdrawal. However, we found no effect of supplemental oxygen following CPAP withdrawal on circulating endocan levels. TRIAL REGISTRATION AND DATE: ISRCTN 17,987,510 19/02/2015.

5.
Neonatology ; 121(5): 584-595, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39226881

RESUMO

BACKGROUND: Less invasive surfactant administration (LISA) has become the preferred method of surfactant administration for spontaneously breathing babies on continuous positive airway pressure (CPAP). SUMMARY: The development of LISA followed the need to combine CPAP and surfactant replacement as mainstay treatment options for respiratory distress syndrome, thereby avoided exposure to positive pressure ventilation. KEY MESSAGES: This review summarises the current knowns and unknowns of LISA including the physiological concept, its relevance for short-term and long-term outcomes and the challenges for practical implementation of LISA as part of a less invasive respiratory care bundle. Further, we provide an update of the evidence on alternatives to LISA, for example, nebulised surfactant administration, pharyngeal deposition of surfactant and delivery via supraglottic airway.

6.
J Sleep Res ; : e14326, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39228120

RESUMO

This study assessed the cost-effectiveness of continuous positive airway pressure treatment for obstructive sleep apnea in Singapore from a health system perspective. The analysis evaluated a 5-year care pathway using a Markov model, considering per-patient costs of treatment, health system cost savings of obstructive sleep apnea and attributed conditions, the effectiveness measured in disability-adjusted life years with a discount rate of 3% and a weighted 5-year continuous positive airway pressure adherence of 74.1% from Singapore studies. Per-patient costs of treatment were from a large public hospital in Singapore. Efficacy of continuous positive airway pressure treatment, health system costs and disability-adjusted life years were obtained from literature; costs are in US dollars. We conducted probabilistic sensitivity analysis, one-way sensitivity analysis and what-if analysis. Based on a willingness-to-pay threshold of US $50,000 per disability-adjusted life year in USA, continuous positive airway pressure therapy was highly cost-effective, with an incremental cost-effectiveness ratio of $13,822 per disability-adjusted life year averted. Compared with the annual total costs of $856 for patients with continuous positive airway pressure treatment diagnosed by an inpatient sleep study, the total costs for those diagnosed by a home sleep test were $625, resulting in a remarkable 27% reduction per patient per year. One-way sensitivity analysis indicated that costs of treatment, effectiveness of continuous positive airway pressure treatment and adherence had a higher impact on the cost-effectiveness of continuous positive airway pressure therapy. The what-if analysis suggested that for continuous positive airway pressure treatment to be cost-effective, adherence rate should be at least 16.1%. These findings provide valuable insights for policymakers in making informed decisions on funding diagnosis and continuous positive airway pressure therapy within Singapore's healthcare system.

7.
Arch Bronconeumol ; 2024 Sep 03.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-39277516

RESUMO

INTRODUCTION: Among all patients with hypertension, those with resistant hypertension (RH) have the highest rates of subclinical organ damage (SOD). The prevalence of obstructive sleep apnea (OSA) is high in RH patients, and it could contribute to SOD. We aimed to investigate how OSA and its treatment are related to SOD in a large cohort of RH patients. METHODS: This is an ancillary analysis to the SARAH study, a multicentre observational cohort aiming to evaluate the impact of OSA on RH. Individuals with RH who were undergoing a sleep study and have information on at least one of the SOD variables (vascular, cardiac or renal damage) were selected. Patients were followed-up for three years. RESULTS: In total, 503 subjects were included. The participants were predominantly male, obese, and the median (IQR) apnea-hypopnea index (AHI) was 15.5 (7.90-31.5)events/h. No differences in the presence of vascular or cardiac damage were observed between OSA and non-OSA patients. A lower estimated glomerular filtration rate (eGFR) was observed in participants with OSA than in those without OSA, with an adjusted effect of -8.69mL/min/1.73m2 (-13.59, -3.79; p value<0.001). Kidney damage was also greater in subjects with OSA, with an adjusted OR (95% CI) of 1.77 (1.09, 2.87; p value=0.02). The eGFR showed a linear dose-response relationship with OSA severity. Among patients treated with CPAP, lower eGFR values were observed in noncompliant subjects. CONCLUSIONS: OSA could contribute to worsening renal function in patients with RH. No compliance with CPAP was associated with lower values of eGFR.

8.
World J Urol ; 42(1): 519, 2024 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-39259389

RESUMO

PURPOSE: To describe the prevalence of nocturia and obstructive sleep apnea (OSA) in a cohort of spinal cord injury (SCI) patients and to describe their association. Additionally, to assess clinical and urodynamic data explaining nocturia and to evaluate the effect of OSA management with continuous positive airway pressure (CPAP). METHOD: Retrospective analysis of data from patients with SCI followed in a tertiary care rehabilitation center with a specialized sleep and neuro-urology units. All adult SCI patients who underwent urodynamic assessment before polysomnography (PSG) between 2015 and 2023 were eligible. Subjective (nocturia) and objective data (urodynamic data, polysomnography, CPAP built-in software) were collated from the Handisom database (database register no. 20200224113128) and the medical records of SCI patients. Statistical testing used Mann-Whitney test for non-parametric variables, Fisher's exact test for contingency analysis and the Spearman correlation test to assess correlations. A p-value < 0.05 was considered significant. Statistical analyses were performed using GraphPad Prism v9. RESULTS: 173 patients (131 males, 42 females) were included. The majority of patients were paraplegic (n = 111 (64,2%)) and had complete lesions (n = 75 (43,4%)). A total of 100 patients had nocturia (57,5%). The prevalence of OSA (Apnea Hypopnea Index (AHI) ≥ 15/h) in the studied population was 61,9%. No correlation was found between nocturia and OSA. A significant difference was observed between patients with and without nocturia in terms of the presence of neurogenic detrusor overactivity (p = 0,049), volume at the first detrusor contraction (p = 0,004) and the bladder functional capacity (p < 0,001). CONCLUSION: Nocturia and OSA are highly prevalent in patients with SCI, but no statistical association was found between these two disorders. A prospective study focusing on nocturnal polyuria will be needed to assess the impact of OSA on lower urinary tract symptoms in SCI patients.


Assuntos
Noctúria , Apneia Obstrutiva do Sono , Traumatismos da Medula Espinal , Humanos , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/epidemiologia , Noctúria/epidemiologia , Noctúria/etiologia , Masculino , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/complicações , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Prevalência , Estudos de Coortes , Idoso , Pressão Positiva Contínua nas Vias Aéreas , Polissonografia , Urodinâmica/fisiologia
9.
J Clin Sleep Med ; 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39162292

RESUMO

STUDY OBJECTIVES: To evaluate the performance of a novel 3D-printed customized nasal mask on patient satisfaction and compliance to continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea (OSA). METHODS: Patients prescribed CPAP therapy with suboptimal CPAP compliance using a conventional CPAP mask (<70% of nights with ≥4 hours per night over 4 weeks) were recruited from the sleep investigation unit of a tertiary hospital. Patients underwent a 3D-facial mapping procedure to have a novel 3D-printed customized nasal mask fabricated which was trialed four weeks. CPAP compliance data download of the same period was conducted with their pre-existing conventional mask and customized mask. Questionnaires assessing symptoms of OSA and mask-related side-effects were administered before and after the trial of the customized mask. RESULTS: Thirty patients (twenty-two males and eight females, age 63.3 ± 12.5 years, BMI 31.7 ± 5.2 kg/m2, apnea-hypopnea index 37.3 ± 21.9 events/h [mean ± standard deviation]) were studied. CPAP was used in a greater proportion of nights with the customized mask (85.7 [66.1, 98.2]% versus 63.2 [13.1, 96.8]%, P=0.009) compared to the conventional mask. Hourly CPAP usage was higher with the customized mask (3.8 [2.7, 5.8] hours versus 2.4 [0.3, 5.0] hours, P=0.016) compared to a conventional mask. Patients preferred the customized mask (P=0.008) and reported less mask-related side effects. CONCLUSIONS: The novel 3D-printed customized mask improved CPAP usage in patients with suboptimal CPAP compliance. Customized CPAP masks may be a suitable option for patients experiencing poor CPAP compliance from mask-related side effects. CLINICAL TRIAL REGISTRATION: Registry: ANZCTR; Title: Conventional vs custom made nasal Continuous Positive Airway Pressure (CPAP) mask for treatment of Obstructive Sleep Apnoea: Pilot study A; Identifier: ACTRN12621001301853; URL: https://anzctr.org.au/Trial/Registration/TrialReview.aspx?id=382142.

10.
Sleep Breath ; 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39162731

RESUMO

AIM: In patients with obstructive sleep apnoea (OSA), the benefits of continuous positive airway pressure (CPAP) therapy are increased for every additional hour of daily CPAP usage. However, the data of predictors of extensive usage is scarce, if any. Therefore, we evaluated potential predictors affecting extensive treatment usage. METHODS: In this retrospective study, we compiled an institutional cohort of consecutive patients diagnosed with who started CPAP therapy 1999-2022 and were included in a wireless telemonitoring system in May 2022 (N = 14,394). Patients using CPAP device ≥ 9 h/d were stratified into a younger (< 65 years; N = 124) and an older group (≥ 65 years; N = 131). RESULTS: We found 255 patients (male 61%) eligible for our study, with a median age of 65 (interquartile range, IQR 55-73) years, and mean body mass index (BMI) of 36 ± 6.9 kg/m2. Median CPAP use was 10 h/d (IQR 10-11). BMI and depressive symptoms (DEPS) in the younger group were higher than in the older group (37.9 ± 7 vs. 34.6 ± 6.4 kg/m2, p < 0.001 and 11 (IQR 5-20) vs. 7 (IQR 5-14), p = 0.01, respectively). During follow-up, the BMI of the younger group increased (39.9 ± 12.5 kg/m2 vs. 37.9 ± 7 kg/m2, p = 0.009). DEPS values decreased in the younger group and became comparable between the groups. In multivariate models, the baseline BMI independently predicted extensive CPAP use among the younger age group, and the mask leak among the older group. CONCLUSION: BMI at baseline in the younger and mask leak in the older group could be independent predictive factors for extensive use of CPAP.

11.
BMC Anesthesiol ; 24(1): 281, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39123127

RESUMO

This systematic review and meta-analysis (SRMA) evaluates the efficacy and safety of Positive Airway Pressure (PAP) therapy in perioperative care for obese surgical patients. We reviewed 24 studies, encompassing data up to March 23, 2023, analyzing the impacts of Continuous Positive Airway Pressure (CPAP) and Bilevel Positive Airway Pressure (BIPAP) on postoperative adverse outcomes, oxygenation, and pulmonary function. Our findings underscore the significant potential of PAP therapy in managing obese patients during the perioperative period, particularly those at substantial risk for postoperative respiratory complications. PAP therapy not only enhances oxygenation levels and lung function but also substantially reduces the incidence of atelectasis and shortens hospital stays, thereby affirming its vital role in improving perioperative outcomes for this patient population.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Obesidade , Complicações Pós-Operatórias , Humanos , Obesidade/complicações , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Respiração com Pressão Positiva/métodos , Assistência Perioperatória/métodos
12.
Indian J Otolaryngol Head Neck Surg ; 76(4): 3212-3220, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39130224

RESUMO

Obstructive sleep apnea (OSA) syndrome, characterized by daytime impairment, affects approximately 1 in 20 adults and can lead to a range of behavioral and cardiovascular abnormalities. Understanding the underlying causes and identifying the specific obstructions within the upper airway is crucial for effective management of this condition. Sleep MRI has emerged as a valuable tool in accurately diagnosing OSA by providing detailed insights into the level, magnitude, and type of obstruction present in affected individuals. One of the key observations made through sleep MRI studies is the increased collapsibility of the velopharynx in apneic patients, particularly during sleep. This heightened collapsibility predisposes the airway to occlusion, contributing to the repetitive breathing pauses characteristic of OSA. By visualizing the dimensions and configurations of the upper airway during both wakefulness and sleep, sleep MRI enables clinicians to pinpoint structural and dynamic factors that play a role in the development and progression of OSA. Moreover, the information gleaned from sleep MRI scans can inform the development of personalized treatment strategies for OSA patients. By identifying specific anatomical abnormalities and dynamic changes in the upper airway, clinicians can tailor interventions such as continuous positive airway pressure (CPAP), oral appliances, or surgical procedures to address the underlying causes of obstruction more effectively. Sleep MRI serves as a powerful diagnostic tool in the management of OSA, offering detailed anatomical and functional insights that guide treatment planning and optimization. Its ability to uncover structural and dynamic factors contributing to airway obstruction enhances our understanding of OSA pathophysiology and facilitates targeted therapeutic interventions aimed at improving patient outcomes and quality of life.

13.
Indian J Otolaryngol Head Neck Surg ; 76(4): 2981-2986, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39130298

RESUMO

Background/objective: Despite the high efficacy of using Continuous positive airway pressure (CPAP) in reversing upper airway obstruction in obstructive sleep apnea (OSA), the efficiency of this treatment is limited due to the low adherence. Mask pressure is suggested to play a significant role in adherence. In this study, we intend to investigate the effect of Lidocaine-prilocaine cream CPAP mask on pressure sensation. Methods: In this study, 75 patients referred to CPAP titration were divided into three groups. In groups one and two, Lidocaine-prilocaine cream and Petroleum jelly were used respectively. The third group had no intervention. Results: VAS discomfort immediately (VAS0), after 15 min (VAS15), and the next day (VAS all) in three groups were compared. VAS0, VAS15, and VAS all were not significantly different among the three groups (P > 0.05). Among participants with VAS0 above 5, VAS15 was significantly lower in intervention groups than the control group (P < 0.05). Conclusion: This study shows that both Petroleum jelly and Lidocaine-prilocaine cream can be used for decreasing pressure sensation during CPAP titration among patients who suffer excessive facial discomfort immediately after putting on a CPAP mask.

14.
HardwareX ; 19: e00559, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39099723

RESUMO

Current positive airway pressure devices cost NZ$800-$2500, posing a financial barrier for the estimated 1 billion individuals worldwide with sleep apnea and those researching respiratory diseases. Increasing diagnoses and research interest in the area necessitate a low-cost, easily accessible alternative. Thus, the mePAP, a high-quality, multipurpose, low-cost (∼NZ$250) positive airway pressure device, was designed and prototyped specifically for respiratory disease research, particularly for sleep apnea. The mePAP allows user customization and provides researchers with an affordable tool for testing positive airway pressure algorithms. Unlike typical commercial devices, the mePAP offers adaptability with open-source data collection and easily modifiable software for implementing and analysing different control and diagnostic algorithms. It features three control modes: constant; bilevel; and automatic; and provides pressures from 4 to 20 cmH2O, controlled via a phone app through Wi-Fi, with a mini-sensor added at the mask for increased accuracy. Validation tests showed the mePAP's performance is comparable to a gold-standard Fisher & Paykel device, with extremely similar output pressures. The mePAP's low cost enhances accessibility and equity, allowing researchers to test ventilation algorithms for sleep apnea and other respiratory conditions, with all data openly available for analysis. Its adaptability and multiple applications increase its usability and usefulness across various research and clinical settings.

15.
World J Diabetes ; 15(7): 1448-1460, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39099813

RESUMO

In this review article, we explore the interplay between obstructive sleep apnea (OSA) and type 2 diabetes mellitus (T2DM), highlighting a significant yet often overlooked comorbidity. We delve into the pathophysiological links between OSA and diabetes, specifically how OSA exacerbates insulin resistance and disrupts glucose metabolism. The research examines the prevalence of OSA in diabetic patients and its role in worsening diabetes-related complications. Emphasizing the importance of comprehensive management, including weight control and positive airway pressure therapy, the study advocates integrated approaches to improve outcomes for patients with T2DM and OSA. This review underscores the necessity of recognizing and addressing OSA in diabetes care to ensure more effective treatment and better patient outcomes.

16.
Clin Hypertens ; 30(1): 19, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39090691

RESUMO

Obstructive sleep apnea (OSA) and hypertension are two important modifiable risk factors for cardiovascular disease and mortality. Numerous studies have highlighted the interplay between these two conditions. We provide a critical review of the current literature on the role of the OSA as a risk factor for hypertension and its effect on blood pressure (BP). We discuss several key topics: the effect of OSA on nocturnal BP, BP response to continuous positive airway pressure (CPAP) treatment, CPAP effect on BP in refractory hypertension, the role of OSA in BP variability (BPV), and maladaptive cardiac remodeling mediated by OSA's effect on BP. Finally, we discuss the unique aspects of ethnicity and social determinants of health on OSA with a focus on Asian populations and the disparity in BP control and cardiovascular outcomes.

17.
Sleep Med Clin ; 19(3): 443-460, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39095142

RESUMO

Telemonitoring in non-invasive ventilation is constantly evolving to enable follow-up of adults and children. Depending on the device and manufacturer, different ventilator variables are displayed on web-based platforms. However, high-granularity measurement is not always available remotely, which precludes breath-by-breath waveforms and precise monitoring of nocturnal gas exchange. Therefore, telemonitoring is mainly useful for monitoring utilization of the device, leaks, and respiratory events. Coordinated relationships between patients, homecare providers, and hospital teams are necessary to transform available data into diagnosis and actions. Telemonitoring is time and cost-consuming. The balance between cost, workload, and clinical benefit should be further evaluated.


Assuntos
Ventilação não Invasiva , Telemedicina , Humanos , Ventilação não Invasiva/métodos , Ventilação não Invasiva/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação
18.
Sleep Med Clin ; 19(3): 405-417, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39095139

RESUMO

This review provides an up-to-date summary of the prevalence, pathophysiology, diagnosis, and treatment of the chronic obstructive pulmonary disease (COPD) and obstructive sleep apnea (OSA) overlap syndrome (OVS). The presence of OVS is high in patients with COPD and in patients with OSA and is associated with profound nocturnal oxygen desaturation and systemic inflammation. There is a high prevalence of cardiovascular disease among patients with OVS and this likely contributes to increased mortality. Observational studies suggest that positive airway pressure therapy improves survival and reduces COPD exacerbations; however, randomized controlled trials will be required to confirm these findings.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/complicações , Doença Pulmonar Obstrutiva Crônica/terapia , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia
19.
Clin Obes ; : e12694, 2024 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-39128971

RESUMO

We aimed to assess the extent to which people with type 2 diabetes or pre-diabetes, obesity (BMI 30-45 kg/m2) and moderate obstructive sleep apnoea (OSA) requiring continuous positive airway pressure ventilation (CPAP) were able to discontinue CPAP following EndoBarrier-related weight loss. We assessed sleep and metabolic parameters before, during and after EndoBarrier in 12 participants with moderate OSA requiring CPAP (75% female, 8/12 [66%] type 2 diabetes, 4/12 [34%] prediabetes, mean ± SD age 52.6 ± 9.7 years, BMI 37.4 ± 3.5 kg/m2, median duration of OSA while on CPAP 9.0 [7.0-15.0] months). With EndoBarrier in-situ, mean ± SD Apnoea Hypopnoea Index (AHI) fell by 9.1 ± 5.0 events/h from 18.9 ± 3.8 to 9.7 ± 3.0 events/h (p < .001) with an associated reduction in symptoms of daytime sleepiness (mean Epworth Sleepiness Score) such that all the 12 participants no longer required CPAP according to National Institute for Health and Care Excellence criteria. After EndoBarrier removal, 10/12 (83%) patients attended follow-up and at 12 months after removal, AHI remained below 15 in 5/10 (50%) patients but in other five the AHI rose above 15 such that restarting CPAP was recommended as justified by their symptoms. Rather than restart CPAP, two patients lost the regained weight and their AHI dropped below 15 again. Thus, 7/10 (70%) of patients were able to remain off CPAP 12 or more months after EndoBarrier removal. These results demonstrate major benefit of EndoBarrier in moderate OSA, allowing all patients to discontinue CPAP during treatment, and with maintenance of improvement at follow-up in 70%. They confirm previously demonstrated metabolic improvements in diabetes and obesity.

20.
J Voice ; 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39153894

RESUMO

OBJECTIVE: The objective of this study is to expand on a novel method for semioccluded vocal tract therapy (SOVT) called controlled supraglottic pressure phonation, and investigate the mechanism that introduced supraglottic pressure mediates a decrease in impedance during SOVT therapy. Instead of the previously used CPAP mask, this study analyzes controlled supraglottic pressure phonation by use of a straw mouthpiece to deliver supraglottic pressure. METHODS: Twenty-six human subjects were randomly assigned to one of four supraglottic pressure levels: 0, 2, 4, and 6 cm H2O, which were controlled through a continuous positive airway pressure device. Subjects were asked to phonate during a SOVT task for one round (referred to as the "short-duration" task) and eight rounds (referred to as the "long-duration" task), in which acoustic and aerodynamic properties were measured before and after. Subjects were surveyed for the levels of discomfort experienced during controlled supraglottic pressure phonation therapy and subjective levels of improvement of vocal economy. RESULTS: Significant differences were observed between pre- and post-task measurement for phonation threshold pressure for the long-duration task for the 2 cmH2O group. Frequency measurement was not found to have statistically significant differences. The perceived phonatory effort was not significantly different at any pressure levels. CONCLUSIONS: Lower supraglottic pressure levels will improve ease of phonation for longer durations, however, shorter-duration tasks will not be effective. Controlled supraglottic pressure phonation coupled with straw phonation may produce an improved vocal economy for those who have access to an oppositional airflow setup.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA