RESUMO
Tissue adhesives are promising alternatives to sutures and staples to achieve wound closure and hemostasis. However, they often do not work well on tissues that are soaked in blood or other biological fluids, and organs that are typically exposed to a variety of harsh environments such as different pH values, nonhomogeneous distortions, continuous expansions and contractions, or high pressures. In this study, a nature-derived multilayered hetero-bioadhesive patch (skin secretion of Andrias davidianus (SSAD)-Patch) based on hydrophilic/hydrophobic pro-healing bioadhesives derived from the SSAD is developed, which is designed to form pressure-triggered strong adhesion with wet tissues. The SSAD-Patch is successfully applied for the sealing and healing of tissue defects within 10 s in diverse extreme injury scenarios in vivo including rat stomach perforation, small intestine perforation, fetal membrane defect, porcine carotid artery incision, and lung lobe laceration. The findings reveal a promising new type of self-adhesive regenerative SSAD-Patch, which is potentially adaptable to broad applications (under different pH values and air or liquid pressures) in sutureless wound sealing and healing.
Assuntos
Adesivos Teciduais , Cicatrização , Animais , Cicatrização/efeitos dos fármacos , Adesivos Teciduais/química , Adesivos Teciduais/farmacologia , Ratos , Suínos , Interações Hidrofóbicas e Hidrofílicas , Pele , EstômagoRESUMO
OBJECTIVE: Controlled twitch mouth pressure (Tw Pmo) via the use of a two-way non-rebreathing valve is a new method to assess diaphragm contractility. The optimal trigger threshold was confirmed. DESIGN: We sought to determine the optimal trigger threshold for 17 healthy subjects (29±4 years) and 17 COPD patients (64±10 years). The Tw Pmo, twitch oesophageal pressure (Tw Pes) and twitch transdiaphragmatic pressure (Tw Pdi) in response to phrenic nerve stimulation were measured using an inspiratory pressure trigger at -1, -2, -3, -4, -5 and -6 cmH2O. RESULTS: The lung volume did not change during triggering at different trigger thresholds using a two-way non-rebreathing valve. The highest correlation between Tw Pmo and Tw Pes in healthy subjects and COPD patients occurred for a -2 cmH2O trigger threshold (r=0.939 and r=0.869, P<0.0001). The narrowest limits of agreement for Tw Pmo and Tw Pes both occurred at -2 cmH2O in healthy subjects, with a bias (range) of -0.4 cmH2O (-1.85 to 1.41), and in COPD patients, with a bias (range) of 0.1 6cmH2O (-1.36-1.67). CONCLUSIONS: We conclude that the measurement of Tw Pmo using a two-way non-rebreathing valve is of clinical value to investigate the suspected diaphragm contractility. The highest trigger threshold for clinical applications was -2 cmH2O.