Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Nutrients ; 14(18)2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36145188

RESUMO

Design, participants, setting, and measurements: Predialysis adult participants with chronic kidney disease (CKD) and mean estimated glomerular filtration rate (eGFR) <45 mL/min per 1.73 m2) were recruited in 2019 to a multicentric double-blinded randomized controlled trial of enzobiotic therapy (synbiotics and proteolytic enzymes) conducted over 12 weeks. The primary objective was to evaluate the efficacy and safety of enzobiotics in reducing the generation of p-cresol sulfate (PCS) and indoxyl sulfate (IS), stabilizing renal function, and improving quality of life (QoL), while the secondary objective was to evaluate the feasibility of the diagnostic prediction of IS and PCS from CKD parameters. Results: Of the 85 patients randomized (age 48.76 years, mean eGFR 23.24 mL/min per 1.73 m2 in the placebo group; age 54.03 years, eGFR 28.93 mL/min per 1.73 m2 in the enzobiotic group), 50 completed the study. The absolute mean value of PCS increased by 12% from 19 µg/mL (Day 0) to 21 µg/mL (Day90) for the placebo group, whereas it decreased by 31% from 23 µg/mL (Day 0) to 16 µg/mL (Day 90) for the enzobiotic group. For IS, the enzobiotic group showed a decrease (6.7%) from 11,668 to 10,888 ng/mL, whereas the placebo group showed an increase (8.8%) from 11,462 to 12,466 ng/mL (Day 90). Each patient improvement ratio for Day 90/Day 0 analysis showed that enzobiotics reduced PCS by 23% (0.77, p = 0.01). IS levels remained unchanged. In the placebo group, PCS increased by 27% (1.27, p = 0.14) and IS increased by 20% (1.20, p = 0.14). The proportion of individuals beyond the risk threshold for PCS (>20 µg/mL) was 53% for the placebo group and 32% for the enzobiotic group. The corresponding levels for IS risk (threshold >20,000 ng/mL) were 35% and 24% for the placebo and enzobiotic groups, respectively. In the placebo group, eGFR decreased by 7% (Day 90) but remained stable (1.00) in the enzobiotic group. QoL as assessed by the adversity ratio decreased significantly (p = 0.00), highlighting an improvement in the enzobiotic group compared to the placebo group. The predictive equations were as follows: PCS (Day 0 = −5.97 + 0.0453 PC + 2.987 UA − 1.310 Creat; IS (Day 0) = 756 + 1143 Creat + 436.0 Creat2. Conclusion: Enzobiotics significantly reduced the PCS and IS, as well as improved the QoL.


Assuntos
Indicã , Insuficiência Renal Crônica , Cresóis , Método Duplo-Cego , Humanos , Indicã/uso terapêutico , Pessoa de Meia-Idade , Peptídeo Hidrolases , Qualidade de Vida , Insuficiência Renal Crônica/diagnóstico , Ésteres do Ácido Sulfúrico , Toxinas Urêmicas
2.
ACS Appl Mater Interfaces ; 11(47): 43843-43856, 2019 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-31663727

RESUMO

Protein-bound uremic toxins (PBUTs) can cause noxious effects in patients suffering from renal failure as a result of inhibiting the transport of proteins and inducing their structural modification. They are difficult to remove through standard hemodialysis (HD) treatment. Herein, we report an organic bioelectronic HD device system for the effective removal of PBUTs through electrically triggered dissociation of protein-toxin complexes. To prepare this system, we employed electrospinning to fabricate electrically conductive quaternary composite nanofiber mats-comprising multiwalled carbon nanotubes (MWCNTs), poly(3,4-ethylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS), poly(ethylene oxide) (PEO), and (3-glycidyloxypropyl)trimethoxysilane (GOPS)-on conventional polyethersulfone (PES) dialysis membranes. These composite nanofiber platforms exhibited (i) long-term water resistance (due to cross-linking among PSS, PEO, and GOPS), (ii) high adhesion strength on the PES membrane (due to GOPS functioning as an adhesion promoter), (iii) enhanced electrical properties [due to the MWCNTs and PEDOT:PSS promoting effective electrical stimulation (ES) operation in devices containing bioelectronic interfaces (BEI)], and (iv) good anticoagulant ability and negligible hemolysis of red blood cells. We employed this organic BEI electronic system as a novel single-membrane HD device to study the removal efficiency of four kinds of uremic toxins [p-cresol (PC), indoxyl sulfate, and hippuric acid as PBUTs; creatinine as a non-PBUT] as well as the effects of ES on lowering the protein binding ratio. Our organic BEI devices provided a high rate of removal of PC with low protein loss after 4 h of a simulated dialysis process. It also functioned with low complement activation, low contact activation levels, and lower amounts of platelet adsorption, suggesting great suitability for use in developing next-generation bioelectronic medicines for HD.


Assuntos
Nanotubos de Carbono/química , Proteínas/química , Diálise Renal/instrumentação , Toxinas Biológicas/química , Uremia/terapia , Adsorção , Cresóis/sangue , Cresóis/química , Eletrônica/instrumentação , Hipuratos/sangue , Hipuratos/química , Humanos , Indicã/sangue , Indicã/química , Polímeros/química , Toxinas Biológicas/sangue , Uremia/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA