Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Infect Dis Health ; 29(3): 124-129, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38609770

RESUMO

BACKGROUND: A rapid large-scale evaluation of a newly available duckbill style P2/N95 respirator, the Care Essentials (CE) MSK-003, was required to determine its suitability for deployment into the Victorian healthcare service. The aims of this study were to assess the feasibility of establishing a rapid, multi-organisational and multi-modal evaluation of the respirator, and to investigate whether this respirator would meet the needs of healthcare workers. METHODS: The evaluation was a collaboration among three healthcare organisations - two tertiary hospitals in metropolitan Melbourne and a rural-based hospital. Participants were healthcare workers undertaking their routine fit tests. They were required to complete quantitative fit testing and a usability assessment survey on the CE MSK-003 respirator. The a priori performance criteria were set as fit test pass rate of >70%, plus satisfactory subjective overall comfort and performance assessments, defined as a rating of adequate, good, or very good in >90% of the cohort. RESULTS: A total of 1070 participants completed the multi-modal assessment within a month. Seventy-eight percent of participants passed their quantitative fit test. Over 90% of survey respondents reported that the CE MSK-003 was adequate, good or very good in terms of its overall comfort and performance assessments. CONCLUSION: We demonstrated that a multi-modal evaluation of a new respirator can be rapidly conducted with a high level of participation in a controlled, consistent manner across multiple organisations. The evaluation results of the CE MSK-003 respirator exceeded our predetermined (a priori) minimal criteria, making it suitable for broad distribution to healthcare organisations.


Assuntos
Pessoal de Saúde , Humanos , Masculino , Feminino , Adulto , Pessoal de Saúde/psicologia , Pessoa de Meia-Idade , Equipamentos Descartáveis , Dispositivos de Proteção Respiratória , Inquéritos e Questionários , Respiradores N95 , COVID-19/prevenção & controle , Vitória , Exposição Ocupacional/prevenção & controle
2.
Front Public Health ; 11: 1218191, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37521986

RESUMO

Introduction: Respirators chosen based on their assigned protection factor (APF) enable wearers to effectively reduce particulate matter concentrations to safe levels when used correctly. As a crucial factor in achieving the intended APF, the fit test has become a necessary procedure in respiratory disease protection. Methods: This study involved 225 participants who underwent a fit test using two reusable types of half masks and two types of full masks. Condensation nuclei counting (CNC) and controlled negative pressure (CNP) were performed. Results: The results revealed that the passing rate of full masks was higher compared to half masks. Specifically, the passing rate for the half masks and the full masks were 84.7 and 91.6%, respectively. Gender exerted a statistically significant effect on the passing rate. Nevertheless, age, educational background, and training exhibited relatively negligible effects. Certain movements, such as facing forward, were identified as key actions with strong correlation. Additionally, talking was considered a key action with a high failure rate due to instantaneous leakages. Most participants failed at the initial step of CNP, but nearly all of them passed the fit test using CNC. Discussion: Therefore, putting on full masks, especially for women, provides optimal protection during work. Furthermore, attention should be given to the displacement and deformation of the respirator during the key actions. When it comes to fit test methods, CNC was found to be more practical and comprehensive compared to CNP. Moreover, additional physiological characteristics, such as double chins, could be explored as potential influential factors.


Assuntos
Exposição Ocupacional , Dispositivos de Proteção Respiratória , Humanos , Feminino , Exposição Ocupacional/prevenção & controle , Material Particulado
3.
Infect Dis Health ; 28(1): 64-70, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36207250

RESUMO

BACKGROUND: The use of respiratory protection remains important in protecting health care workers from airborne pathogens such as viruses. Respirator supply is constantly changing with new models regularly becoming available. Health services should consider a broad range of factors when procuring respirators, including the results of quantitative fit testing in a representative sample of the workforce. Subjective comfort factors and compatibility with a variety of workplace tasks, such as suitability for staff use near magnetic resonance imaging (MRI) environments where relevant, should also be considered. This article compares the quantitative fit factors and user assessments for two styles of flat-fold cup respirators, Care Essentials (CE) MSK-002 P2 and BYD DE2322 N95. METHODS: Quantitative fit tests (QNFT) were performed on 300 participants on each model of respirator in this randomised crossover trial. Participants then completed a questionnaire on their assessments of each respirator. RESULTS: The Care Essentials MSK-002 had a significantly higher quantitative fit test pass rate than the BYD DE2322 (57% vs 18%, p < 0.001). There was no concordance between fit test pass rates for each model. Additionally, the Care Essentials MSK-002 achieved significantly higher scores on each of the responses in the subjective usability survey. CONCLUSION: It is recommended that the Care Essentials MSK-002 be made available for health care use due to higher QNFT pass rates, higher subjective usability assessment scores, plus its potential for use in MRI environments when compared to the BYD DE2322.


Assuntos
Exposição Ocupacional , Dispositivos de Proteção Respiratória , Humanos , Estudos Cross-Over , Interface Usuário-Computador , Exposição Ocupacional/prevenção & controle , Desenho de Equipamento , Ventiladores Mecânicos
4.
Saf Health Work ; 13(4): 500-506, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36579005

RESUMO

This study evaluated the consistency between two quantitative fit test devices with different methods of ambient aerosol counting. Three types of respirators (N95, half mask, and full facepiece) were worn by 50 participants (male, n = 25; female, n = 25), PortaCount (Pro+ 8038) and MT (05U) were connected to one probe to one mask, and fit factors (FFs) were measured simultaneously with the original and modified protocols. As a result of comparing MT FFs with PortaCount FFs as references and by applying for the pass/fail criteria (FF = 100), the consistency between the two devices for half masks and full facepieces was very high. N95 was somewhat weaker than the two type of respirators in the consistency; however, the correlation between the two devices was very strong (p < 0.0001). The results showed that an FF of 100 as measured by PortaCount was likely to be measured as 75 by the MT. Therefore, when performing the fit test for N95 using the MT and pass level of FF 100, a certain level of adjustment is necessary, whether end-user or putting a scaling factor by manufacturer.

5.
J Oral Sci ; 64(4): 271-273, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36070924

RESUMO

PURPOSE: This study aimed to test the face seal of a surgical mask modified using a custom-made mask fitter or by sealing all borders with micropore tape, in comparison to the N95 mask as a gold standard. METHODS: Fifteen participants were assigned to wear an N95 mask, a surgical mask sealed with a mask fitter, and a surgical mask sealed with micropore tape. A quantitative fit test was performed using a Portacount respirator fit tester in 4 different actions: bending over, talking, moving the head from side to side, and moving the head up and down. RESULTS: The N95 showed the highest overall fit factor score (134.67 ± 66.62), passing Occupational Safety and Health Administration (OSHA) standards. The surgical mask alone had the lowest overall fit factor score of 4.73 ± 3.30. Modification of the surgical mask using a mask fitter or micropore tape significantly increased the overall fit factor to 35.33 ± 14.58 and 29.33 ± 9.73, respectively. This pattern was similar for all exercises. CONCLUSION: The N95 was the only mask type that passed the OSHA standard for protection. Use of a mask fitter or micropore tape significantly increased the face seal of a surgical mask. This could offer useful levels of protection during a non-aerosol dental procedure.


Assuntos
Exposição Ocupacional , Dispositivos de Proteção Respiratória , Desenho de Equipamento , Humanos , Exposição Ocupacional/prevenção & controle
6.
Infect Dis Health ; 27(2): 61-65, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34799300

RESUMO

BACKGROUND: Various styles of N95/P2 filtering facepiece respirators (FFRs) have been used by Australian healthcare workers (HCWs) during the COVID-19 pandemic. This is usually driven by the national stockpile availability. Many studies demonstrate three-panel flat-fold N95/P2 FFRs have higher quantitative fit test (QNFT) pass rates than other FFR styles. This prospective randomized crossover study utilized QNFT to evaluate the performance of the new three-panel flat-fold FFR, the Trident™ P2 respirator compared to the previously most effective model, the 3M™ Aura™ 9320A + N95 respirator. METHODS: We recruited 500 participants who completed online training and QNFT on both respirators. The order of the respirator being examined first was randomly allocated. The primary outcome was the QNFT pass rate. Secondary outcomes included the overall fit factor, the individual fit factor for each exercise, and the first-attempt QNFT pass rate. RESULTS: We found that both the overall and first-attempt QNFT pass rates of the Trident P2 respirator were significantly higher than the 3M Aura (99.2% vs 92.6%, p < 0.001; and 92.6% vs 76.4%, p < 0.001 respectively). The overall fit factor and the individual fit factor were also significantly higher for the Trident FFR than the 3M Aura. CONCLUSIONS: This study is the first to report hospital-based QNFT results of the Trident FFR, demonstrating very high first-time and overall pass rates. Our findings are consistent with previous research showing very high QNFT pass rates with three-panel flat-fold FFRs. These findings are important for pandemic preparedness with respect to the stockpiling and safe utilization of N95/P2 respirators.


Assuntos
COVID-19 , Exposição Ocupacional , Dispositivos de Proteção Respiratória , Austrália , COVID-19/prevenção & controle , Estudos Cross-Over , Desenho de Equipamento , Humanos , Respiradores N95 , Pandemias/prevenção & controle , Estudos Prospectivos , Ventiladores Mecânicos
7.
J Korean Med Sci ; 36(28): e209, 2021 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-34282608

RESUMO

BACKGROUND: Ear-loop-type Korean Filter 94 masks (KF94 masks, equivalent to the N95 and FFP2) are broadly used in health care settings in Korea for the coronavirus disease 2019 pandemic. METHODS: A prospective randomized open-label study was designed to identify differences in the fitting performance between mask wearing methods in three different types of KF94 mask with ear loops between January to March 2021. General-fitting involved wearing an ear-loop-type KF94 mask, and tight-fitting involved wearing a mask aided by a clip connecting the ear loops. Each of the 30 participants wore three types of masks according to a randomly assigned order in both methods and performed a total of six quantitative fit tests (QNFTs) according to the occupational safety and health administration protocol. RESULTS: All fit factors (FFs) measured by the QNFT were significantly higher for tight-fitting method with the clip in all KF94 masks (P < 0.001). However, the total FFs were very low, with a median (interquartile range) of 6 (3-23) and 29 (9-116) for general-fitting and tight-fitting, respectively. When wearing tightly, the horizontal 3-fold type mask with adjustable ear-loop length had the highest FF, with a median of 125, and the QNFT pass rate (FF ≥ 100) increased significantly from 4 (13%) to 18 (60%). CONCLUSION: Even with sufficient filter efficiency, ear-loop-type-KF94 masks do not provide adequate protection. However, in relatively low-risk environments, wearing a face-seal adjustable KF94 mask and tight wearing with a clip can improve respiratory protection for healthcare workers. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04794556.


Assuntos
COVID-19/prevenção & controle , Respiradores N95 , SARS-CoV-2 , Adulto , Feminino , Pessoal de Saúde , Humanos , Masculino , Estudos Prospectivos
8.
Infect Dis Health ; 26(4): 265-272, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34176771

RESUMO

BACKGROUND: In October 2020, the Royal Melbourne Hospital implemented a Respiratory Protection Program (RPP), which was initiated by the Victorian Government. This study was to evaluate the effectiveness of the program. METHODS: A cohort of 158 employees, who were identified as high risk to respiratory biohazard exposure, were invited to participate in the RPP. We provided a bundle of interventions, which included an online training package, and mandatory quantitative fit testing. The main outcomes included the participants' knowledge and attitude toward respiratory protection equipment (RPE), which were assessed via an online survey. Their donning and doffing skills, and user seal check techniques on four different types of N95 respirators were also assessed by an observer using a pre-determined marking sheet. We compared these outcomes before and after participation in the program. RESULTS: There was a total of 125 participants, all of whom completed the knowledge and attitude assessment, and 69 completed the skill assessment before and after the program. There was a statistically significant improvement in their knowledge scores, donning and doffing skills, and user seal check techniques after participation in the RPP. Participants also reported significant increased level of confidence in their RPE knowledge, training and skills; and workplace safety. CONCLUSION: This initial report of the implementation of a novel RPP in a Victorian major tertiary hospital provides guidance on the benefits to respiratory protection, staff knowledge, skills, confidence and morale that can be acquired from a scalable online training package combined with mandatory quantitative fit testing.


Assuntos
Dispositivos de Proteção Respiratória , Hospitais Públicos , Humanos , Local de Trabalho
9.
Cureus ; 13(4): e14382, 2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33976998

RESUMO

Background There is limited knowledge about adenoma detection rates (ADRs) in patients with a positive fecal immunochemical test (FIT). We hypothesized that colonoscopy performed after FIT would result in higher ADRs. Methods We reviewed ADRs for colonoscopies performed after a positive FIT test and compared them to ADR rates for routine colonoscopy performed without an initial FIT test between November 2014 and March 2017 at multiple endoscopy sites. Results A total of 979 patients underwent a FIT testing in the Texas panhandle, of whom 12.1% (n=119) tested positive. Also, 32.8% (n=39) were found to have one or more tubular adenomatous polyps on final pathological examination. Among these patients, the majority were female (64.1%; n=25). Of the patients, 15.9% (n=19) had a hyperplastic polyp, 1.7% (n=2) had findings consistent with ulcerative colitis, and 0.8% (n=1) were positive for an adenocarcinoma. In the control group of 2,603 patients in whom routine colonoscopy was performed as the initial tool for screening, 719 were found to have one or more tubular adenomas, with an ADR rate of 27.5%. In this group, the cancer rate was found to be 1%. Conclusions There was a significant increase in the ADR when colonoscopy is conducted after a positive FIT test. Recommending colonoscopies after a positive FIT test will not only improve ADRs significantly but also lower the overall healthcare cost for screening colon cancer in this era of escalating healthcare costs.

10.
Anaesth Intensive Care ; 49(2): 112-118, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33818131

RESUMO

N95 particulate respirator masks are currently recommended for all healthcare workers who care for patients with suspected or confirmed coronavirus disease (COVID-19) when performing aerosol-generating procedures. The protection provided by N95 particulate respirator masks is dependent on the filter's efficiency and seal quality. In this prospective randomised crossover study, we conducted the user seal check and the quantitative fit test on two readily available duckbill models of N95 masks, the Halyard Fluidshield® N95 (Halyard, Alpharetta, GA, USA) and the BSN Medical ProShield® N-95 (BSN Medical, Mount Waverley, Victoria) particulate respirator masks. We recruited a total of 96 anaesthetic staff, of whom 26% were of South-East Asian ethnicity. We found that both types of masks provided reasonably high fit test pass rates among our participants and there was no significant difference between the two brands (77% for the Fluidshield and 65% for the ProShield, P = 0.916). Ninety-two percent of the participants could find at least one well-fitted mask among these two types of masks. We also demonstrated that the user seal check had low accuracy and low concordance (kappa coefficient of 0.16 for the Fluidshield and 0.08 for the ProShield) when compared to the quantitative fit test, and hence was not a reliable method to test seal quality.


Assuntos
COVID-19 , Exposição Ocupacional , Estudos Cross-Over , Humanos , Máscaras , Estudos Prospectivos , SARS-CoV-2 , Ventiladores Mecânicos
11.
J Environ Health Sci Eng ; 19(1): 805-817, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33875931

RESUMO

PURPOSE: Frontline health care workers (HCWs) must wear a standard N95 or FFP2 respirator during worldwide pandemics of respiratory diseases including COVID-19 to protect against airborne infectious pathogens when performing care activities. This study aimed to quantitatively investigate the fit of most of the common FFRs used during the COVID-19 pandemic in Iran. METHODS: A total of 37 volunteers were fit tested in 20 selected FFRs in a randomized order. The selected FFRs were underwent quantitative fit testing by PortaCount® model 8038. To determine the effects of face sizes on respirator fit, the participants' facial dimensions were measured using a digital caliper. RESULTS: The rate of passing fit tests for the studied FFRs were surprisingly low with 11 out of 20 FFRs having less than 10% passing fit tests and the best performers having only 43% and 27% passing fit tests (brands 2 and 20, respectively). Cup-shaped respirators provided significantly greater fit than the vertical flat-fold ones (p < 0.001). A significantly different FFs were found among the respirator brands (F = 13.60, p < 0.001). CONCLUSION: Overall, unacceptably low fit factors were obtained from the studied FFRs. The main reasons for this are suspected to single size and style for each studied FFR. It confirms the importance and requirement of the proper respirator selection in that way fitted optimally into facial dimensions, appropriate usage, and properly performing the fit testing procedure. A unique fit test panel should be developed to guide respirator wearers in selecting the appropriate FFR for their specific face sizes.

12.
Cureus ; 13(2): e13542, 2021 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-33786247

RESUMO

Objectives A surge in the demand for N95 filtering facepiece respirators (N95 respirators) due to the worldwide spread of coronavirus disease 2019 (COVID-19) has resulted in a global shortage of N95 respirators. This study was performed to evaluate the clinical validation of reusing N95 respirators following stringent fit test protocols. Methods After passing the first fit test, we prospectively enrolled healthcare workers who used N95 respirators for two hours per shift (duckbill-shaped HPR-R/HPR-S, dome-shaped Hi-Luck 350, and three-panel flat-fold respirators 9211) in settings such as bronchoscopy or respiratory specimen sampling. These procedures were repeated for up to three weeks, with the fit test performed every week. At each timing of the fit test, we used a fit-testing system for quantitatively evaluating particle leakage. Results A total of 41 participants were enrolled, including 24 doctors and 17 nurses, of whom 25 were women. The pass rate of successful reuse over three observational weeks using four fit tests was 85.4%, which was comparable among the three types of N95 respirators. Six (14.6%) participants failed the fit test, while no participants dropped out of protocol due to either N95 respirator damage or contamination. Among the six dropped out participants, four reused the duckbill-shaped type and two reused the three-panel flat-fold type. All participants using the cup-shaped type mask successfully completed the protocol. However, the passing rate of this study was not statistically different among the three types of N95 respirators. Conclusion This study shows that N95 respirators can be safely reused for a short period irrespective of their type, as quantitatively assessed by fit tests.

13.
Exp Biol Med (Maywood) ; 246(6): 740-748, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33325749

RESUMO

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.


Assuntos
COVID-19/prevenção & controle , Descontaminação/métodos , Respiradores N95/provisão & distribuição , 2-Propanol/farmacologia , Detergentes/farmacologia , Humanos , Peróxido de Hidrogênio/farmacologia , SARS-CoV-2 , Hipoclorito de Sódio/farmacologia , Eletricidade Estática , Raios Ultravioleta
14.
J Hosp Infect ; 107: 50-56, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33075406

RESUMO

BACKGROUND: Coronavirus disease 2019 has stretched the ability of many institutions to supply needed personal protective equipment, especially N95 respirators. N95 decontamination and re-use programmes provide one potential solution to this problem. Unfortunately, a comprehensive evaluation of the effects of decontamination on the fit of various N95 models using a quantitative fit test (QNFT) approach is lacking. AIMS: To investigate the effects of up to eight rounds of vaporized hydrogen peroxide (VHP) decontamination on the fit of N95 respirators currently in use in a hospital setting, and to examine if N95 respirators worn by one user can adapt to the face shape of a second user with no compromise to fit following VHP decontamination. METHODS: The PortaCount Pro+ Respirator Fit Tester Model 8038 was used to quantitatively define functional integrity, measured by fit, of N95 respirators following decontamination with VHP. FINDINGS: There was an observable downward trend in the functional integrity of Halyard Fluidshield 46727 N95 respirators throughout eight cycles of decontamination with VHP. Functional integrity of 3M 1870 N95 respirators was reduced significantly after the respirator was worn, decontaminated with VHP, and then quantitatively fit tested on a second user. Furthermore, inconsistencies between qualitative fit test and QNFT results were uncovered that may have strong implications on the fit testing method used by institutions. CONCLUSIONS: The data revealed variability in the functional integrity of different N95 models after VHP decontamination, and exposed potential limitations of N95 decontamination and re-use programmes.


Assuntos
COVID-19/prevenção & controle , Descontaminação/métodos , Descontaminação/normas , Reutilização de Equipamento , Peróxido de Hidrogênio/farmacologia , Respiradores N95/normas , Humanos , Volatilização
15.
Am J Emerg Med ; 38(1): 12-17, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-30955924

RESUMO

BACKGROUND: N95 filtering facepiece respirators (N95 respirators) may not provide adequate protection against respiratory infections during chest compression due to inappropriate fitting. METHODS: This was a single-center simulation study performed from December 1, 2016, to December 31, 2016. Each participant underwent quantitative fit test (QNFT) of N95 respirators according to the Occupational Safety and Health Administration protocol. Adequacy of respirator fit was represented by the fit factor (FF), which is calculated as the number of ambient particles divided by the number inside the respirator. We divided all participants into the group that passed the overall fit test but failed at least one individual exercise (partially passed group [PPG]) and the group that passed all exercises (all passed group [APG]). Then, the participants performed three sessions of continuous chest compressions, each with a duration of 2 min, while undergoing real-time fit testing. The primary outcome was any failure (FF < 100) of the fit test during the three bouts of chest compression. RESULTS: Forty-four participants passed the QNFT. Overall, 73% (n = 32) of the participants failed at least one of the three sessions of chest compression; the number of participants who failed was significantly higher in the PPG than in the APG (94% vs. 61%; p = 0.02). Approximately 18% (n = 8) of the participants experienced mask fit failures, such as strap slipping. CONCLUSIONS: Even if the participants passed the QNFT, the N95 respirator did not provide adequate protection against respiratory infections during chest compression.


Assuntos
Reanimação Cardiopulmonar , Doenças Transmissíveis/transmissão , Controle de Infecções/instrumentação , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Corpo Clínico Hospitalar , Dispositivos de Proteção Respiratória/normas , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Exposição Ocupacional , Simulação de Paciente , Estados Unidos
16.
Am J Infect Control ; 45(9): 974-978, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28526306

RESUMO

BACKGROUND: The adequate fit of an N95 respirator is important for health care workers to reduce the transmission of airborne infectious diseases in the clinical setting. This study aimed to evaluate whether adequately sealed N95 respirators may provide consistent protection for the wearer while performing nursing procedures. METHODS: Participants were a group of nursing students (N = 120). The best fitting respirator for these participants was identified from the 3 common models, 1860, 1860S, and 1870+ (3M), using the quantitative fit test (QNFT) method. Participants performed nursing procedures for 10-minute periods while wearing a backpack containing the portable aerosol spectrometers throughout the assessment to detect air particles inside the respirator. RESULTS: The average fit factor of the best fitting respirator worn by the participants dropped significantly after nursing procedures (184.85 vs 134.71) as detected by the QNFT. In addition, significant differences in particle concentration of different sizes (>0.3, >0.4, >1.0, and >4.0 µm) inside the respirator were detected by the portable aerosol spectrometers before, during, and after nursing procedures. CONCLUSIONS: Body movements during nursing procedures may increase the risk of face seal leakage. Further research, including the development of prototype devices for better respirator fit, is necessary to improve respiratory protection of users.


Assuntos
Aerossóis/análise , Exposição Ocupacional/análise , Estudantes de Enfermagem , Ventiladores Mecânicos , Adolescente , Adulto , Bacharelado em Enfermagem , Desenho de Equipamento , Face/anatomia & histologia , Face/fisiologia , Feminino , Humanos , Masculino , Teste de Materiais , Exposição Ocupacional/prevenção & controle , Tamanho da Partícula , Reprodutibilidade dos Testes
17.
J Occup Environ Hyg ; 11(7): 479-84, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24467771

RESUMO

Ten years ago, three differently sized half-mask facepiece prototypes were constructed from silicon using computer graphics and statistical analysis to fit them according to Korean facial dimensions. The purpose of this study was to complete the medium-size half-mask respirator based on the prototype, which would provide an adequate fit performance for male workers at a shipyard, Hyundai Samho Heavy Industry Co., in Korea. The complete respirator--the hardness 55--was manufactured with existing accessories such as a filter, exhalation valve, and strap attached. The fit performance test was conducted by performing a quantitative fit-test on 48 male subjects: workers who usually wear half-mask respirators (Dobulife Tech Co., Model DM-911, Gwangju, Gyeonggi-do, Korea). The results showed that the hardness 55 provided male subject workers with much better fit performance than the existing mask constructed by the same company. Because softness of the material of the facepiece, in particular the inner part, influenced faceseal leakage, further research on developing better-fit respirator facepieces should consider carefully the fine control of material softness.


Assuntos
Máscaras/normas , Exposição Ocupacional/prevenção & controle , Dispositivos de Proteção Respiratória/normas , Navios , Desenho de Equipamento , Face/anatomia & histologia , Humanos , Masculino , Teste de Materiais , República da Coreia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA