Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
Appl Microbiol Biotechnol ; 108(1): 414, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985204

RESUMO

Airborne animal viral pathogens can rapidly spread and become a global threat, resulting in substantial socioeconomic and health consequences. To prevent and control potential epidemic outbreaks, accurate, fast, and affordable point-of-care (POC) tests are essential. As a proof-of-concept, we have developed a molecular system based on the loop-mediated isothermal amplification (LAMP) technique for avian metapneumovirus (aMPV) detection, an airborne communicable agent mainly infecting turkeys and chickens. For this purpose, a colorimetric system was obtained by coupling the LAMP technique with specific DNA-functionalized AuNPs (gold nanoparticles). The system was validated using 50 different samples (pharyngeal swabs and tracheal tissue) collected from aMPV-infected and non-infected chickens and turkeys. Viral detection can be achieved in about 60 min with the naked eye, with 100% specificity and 87.88% sensitivity for aMPV. In summary, this novel molecular detection system allows suitable virus testing in the field, with accuracy and limit of detection (LOD) values highly close to qRT-PCR-based diagnosis. Furthermore, this system can be easily scalable to a platform for the detection of other viruses, addressing the current gap in the availability of POC tests for viral detection in poultry farming. KEY POINTS: •aMPV diagnosis using RT-LAMP is achieved with high sensitivity and specificity. •Fifty field samples have been visualized using DNA-nanoprobe validation. •The developed system is a reliable, fast, and cost-effective option for POCT.


Assuntos
Galinhas , Ouro , Metapneumovirus , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Infecções por Paramyxoviridae , Doenças das Aves Domésticas , Sensibilidade e Especificidade , Metapneumovirus/genética , Metapneumovirus/isolamento & purificação , Animais , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/economia , Galinhas/virologia , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/economia , Infecções por Paramyxoviridae/diagnóstico , Infecções por Paramyxoviridae/veterinária , Infecções por Paramyxoviridae/virologia , Doenças das Aves Domésticas/virologia , Doenças das Aves Domésticas/diagnóstico , Ouro/química , Perus , Nanopartículas Metálicas/química , Limite de Detecção , Colorimetria/métodos , DNA Viral/genética
2.
J Virol Methods ; 327: 114947, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38703833

RESUMO

Rubella virus infection during early pregnancy sometimes causes severe birth defects termed congenital rubella syndrome. Although there are safe and effective live-attenuated vaccines, rubella has only been certified as eliminated in the Americas within the six World Health Organization regions. Rubella remains an endemic disease in many regions, and outbreaks occur wherever population immunity is insufficient. There are two main methods for diagnosis of rubella: detection of anti-rubella IgM antibodies by enzyme immunoassay and detection of the viral genome by real-time RT-PCR. Both of these methods require substantial time and effort. In the present study, a rapid rubella detection assay using real-time fluorescent reverse transcription loop-mediated isothermal amplification with quenching primers was developed. The time required for the new assay was one-half that required for a real-time RT-PCR assay. The assay had 93.6% positive percent agreement and 100% negative percent agreement for clinical specimens compared with the real-time RT-PCR assay. The new assay is considered useful for diagnosis of rubella in areas where rubella is endemic.


Assuntos
Primers do DNA , Técnicas de Amplificação de Ácido Nucleico , Vírus da Rubéola , Rubéola (Sarampo Alemão) , Vírus da Rubéola/genética , Vírus da Rubéola/isolamento & purificação , Rubéola (Sarampo Alemão)/diagnóstico , Rubéola (Sarampo Alemão)/virologia , Humanos , Técnicas de Amplificação de Ácido Nucleico/métodos , Primers do DNA/genética , Sensibilidade e Especificidade , Técnicas de Diagnóstico Molecular/métodos , Fatores de Tempo , Feminino
3.
BMC Microbiol ; 24(1): 68, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38413863

RESUMO

OBJECTIVES: In the current study, for the first time, we reported a novel HCV molecular diagnostic approach termed reverse transcription loop-mediated isothermal amplification integrated with a gold nanoparticles-based lateral flow biosensor (RT-LAMP-AuNPs-LFB), which we developed for rapid, sensitive, specific, simple, and visual identification of HCV. METHODS: A set of LAMP primer was designed according to 5'untranslated region (5'UTR) gene from the major HCV genotypes 1b, 2a, 3b, 6a, and 3a, which are prevalent in China. The HCV-RT-LAMP-AuNPs-LFB assay conditions, including HCV-RT-LAMP reaction temperature and time were optimized. The sensitivity, specificity, and selectivity of our assay were evaluated in the current study. The feasibility of HCV-RT-LAMP-AuNPs-LFB was confirmed through clinical serum samples from patients with suspected HCV infections. RESULTS: An unique set of HCV-RT-LAMP primers were successfully designed targeting on the 5'UTR gene. The optimal detection process, including crude nucleic acid extraction (approximately 5 min), RT-LAMP reaction (67℃, 30 min), and visual interpretation of AuNPs-LFB results (~ 2 min), could be performed within 40 min without specific instruments. The limit of detection was determined to be 20 copies per test. The HCV-RT-LAMP-AuNPs-LFB assay exhibited high specificity and anti-interference. CONCLUSIONS: These preliminary results confirmed that the HCV-RT-LAMP-AuNPs-LFB assay is a sensitive, specific, rapid, visual, and cost-saving assay for identification of HCV. This diagnostic approach has great potential value for point-of-care (POC) diagnostic of HCV, especially in resource-challenged regions.


Assuntos
Técnicas Biossensoriais , Hepatite C , Nanopartículas Metálicas , Humanos , Hepacivirus/genética , Ouro , Sensibilidade e Especificidade , Regiões 5' não Traduzidas , Hepatite C/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Diagnóstico Molecular/métodos , Técnicas Biossensoriais/métodos
4.
Anal Chim Acta ; 1287: 342072, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38182338

RESUMO

BACKGROUND: The COVID-19 pandemic has led to a rise in point-of-care (POC) and home-based tests, but concerns over usability, accuracy, and effectiveness have arisen. The incorporation of internal amplification controls (IACs), essential control for translational POC diagnostics, could mitigate false-negative and false-positive results due to sample matrix interference or inhibition. Although emerging POC nucleic acid amplification tests (NAATs) for detecting SARS-CoV-2 show impressive analytical sensitivity in the lab, the assessment of clinical accuracy with IACs is often overlooked. In some cases, the IACs were run spatially, complicating assay workflow. Therefore, the multiplex assay for pathogen and IAC is needed. RESULTS: We developed a one-pot duplex reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay for saliva samples, a non-invasive and simple collected specimen for POC NAATs. The ORF1ab gene of SARS-CoV-2 was used as a target and a human 18S ribosomal RNA in human saliva was employed as an IAC to ensure clinical reliability of the RT-LAMP assay. The optimized assay could detect SARS-CoV-2 viral particles down to 100 copies/µL of saliva within 30 min without RNA extraction. The duplex RT-LAMP for SARS-CoV-2 and IAC is successfully amplified in the same reaction without cross-reactivity. The valid results were easily visualized in triple-line lateral flow immunoassay, in which two lines (flow control and IAC lines) represent valid negative results and three lines (flow control, IAC, and test line) represent valid positive results. This duplex assay demonstrated a clinical sensitivity of 95%, specificity of 100%, and accuracy of 96% in 30 clinical saliva samples. SIGNIFICANCE: IACs play a crucial role in ensuring user confidence with respect to the accuracy and reliability of at-home and POC molecular diagnostics. We demonstrated the multiplex capability of SARS-COV-2 and human18S ribosomal RNA RT-LAMP without complicating assay design. This generic platform can be extended in a similar manner to include human18S ribosomal RNA IACs into different clinical sample matrices.


Assuntos
Pandemias , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Reprodutibilidade dos Testes , Testes Imediatos , SARS-CoV-2/genética , RNA Ribossômico
5.
medRxiv ; 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37873363

RESUMO

Background: The COVID-19 pandemic has led to a rise in point-of-care (POC) and home-based tests, but concerns over usability, accuracy, and effectiveness have arisen. The incorporation of internal amplification controls (IACs), essential control for translational POC diagnostics, could mitigate false-negative and false-positive results due to sample matrix interference or inhibition. Although emerging POC nucleic acid amplification tests (NAATs) for detecting SARS-CoV-2 show impressive analytical sensitivity in the lab, the assessment of clinical accuracy with IACs is often overlooked. In some cases, the IACs were run spatially, complicating assay workflow. Therefore, the multiplex assay for pathogen and IAC is needed. Results: We developed a one-pot duplex reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay for saliva samples, a non-invasive and simple collected specimen for POC NAATs. The ORF1ab gene of SARS-CoV-2 was used as a target and a human 18S ribosomal RNA in human saliva was employed as an IAC to ensure clinical reliability of the RT-LAMP assay. The optimized assay could detect SARS-CoV-2 viral particles down to 100 copies/µL of saliva within 30 minutes without RNA extraction. The duplex RT-LAMP for SARS-CoV-2 and IAC is successfully amplified in the same reaction without cross-reactivity. The valid results were easily visualized in triple-line lateral flow immunoassay, in which two lines (flow control and IAC lines) represent valid negative results and three lines (flow control, IAC, and test line) represent valid positive results. This duplex assay demonstrated a clinical sensitivity of 95%, specificity of 100%, and accuracy of 96% in 30 clinical saliva samples. Significance: IACs play a crucial role in ensuring user confidence with respect to the accuracy and reliability of at-home and POC molecular diagnostics. We demonstrated the multiplex capability of SARS-COV-2 and human18S ribosomal RNA RT-LAMP without complicating assay design. This generic platform can be extended in a similar manner to include human18S ribosomal RNA IACs into different clinical sample matrices.

6.
Viruses ; 15(10)2023 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-37896904

RESUMO

Rice black-streaked dwarf virus (RBSDV) infects rice and maize, and seriously affects rice yields in main rice-producing areas. It can be transmitted via small brown planthopper (SBPH: Laodelphax striatellus Fallén). To more rapidly, sensitively, and highly throughput diagnose RBSDV in the wild condition, we first purified the recombinant His-CPRBSDV protein, and prepared the polyclonal antibodies against the His-CPRBSDV protein (PAb-CPRBSDV). Based on the PAb-CPRBSDV, we developed a series of serological detections, such as Western blot, an enzyme-linked immunosorbent assay (ELISA), and a dot immunoblotting assay (DIBA). Furthermore, we developed a serological-based reverse-transcription loop-mediated isothermal amplification assay (S-RT-LAMP) that could accurately detect RBSDV in the wild. Briefly, the viral genomic dsRNA together with viral CP were precipitated by co-immunoprecipitation using the PAb-CPRBSDV, then the binding RNAs were crudely isolated and used for RT-LAMP diagnosis. Using the prepared PAb-CPRBSDV, four serology-based detection methods were established to specifically detect RBSDV-infected rice plants or SBPHs in the wild. The method of S-RT-LAMP has also been developed to specifically, high-throughput, and likely detect RBSDV in rice seedlings and SBPHs simultaneously. The antiserum prepared here laid the foundation for the rapid and efficient detection of RBSDV-infected field samples, which will benefit for determination of the virulence rate of the transmission vector SBPH and outbreak and epidemic prediction of RBSDV in a rice production area.


Assuntos
Hemípteros , Oryza , Vírus de Plantas , Reoviridae , Animais , Técnicas de Amplificação de Ácido Nucleico , Técnicas de Diagnóstico Molecular , Vírus de Plantas/genética , Anticorpos , Doenças das Plantas
7.
Int J Mol Sci ; 24(18)2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37762149

RESUMO

Newcastle disease (ND) is a highly pathogenic viral infection of poultry with significant economic impacts worldwide. Despite the widespread use of vaccines, ND outbreaks continue to occur even within vaccinated poultry farms. Furthermore, novel Newcastle disease virus (NDV) genotypes are emerging in poultry, increasing the need for the development of rapid, accurate, and simple diagnostic methods. We therefore developed two novel sets of visual reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays based on highly conserved regions of the HN and F genes. The limits of detection of the NDV-Common-LAMP assay, for all the NDV strains, were 103.0 EID50/0.1 mL for Kr005 and 102.0 EID50/0.1 mL for Lasota within 35 min. The sensitivity of the NDV-Patho-LAMP assay, used for the strain differentiation of virulent NDV, was 102.0 EID50/0.1 mL for Kr005. No amplification was detected for the non-NDV templates. Next, we probed 95 clinical strains and 7 reference strains with the RT-LAMP assays to assess the feasibility of their use in diagnostics. We observed no cross-reactivity across the 102 strains. Furthermore, there was 100% congruence between the RT-LAMP assays and full-length sequencing of the target genes, indicating the potential for visual RT-LAMP in the identification and differentiation of NDV. These novel RT-LAMP assays are ideally suited for the field or resource-limited environments to facilitate the faster detection and differentiation of NDV, which can reduce or avoid further spread.


Assuntos
Doença de Newcastle , Vírus da Doença de Newcastle , Animais , Vírus da Doença de Newcastle/genética , Transcrição Reversa , Doença de Newcastle/diagnóstico , Bioensaio
8.
Exp Ther Med ; 26(2): 398, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37522063

RESUMO

The detection of coronavirus disease 2019 cases represents a significant challenge at the epidemiological level. Limitations exist in effectively detecting asymptomatic cases, achieving good follow-up in hospitals without the infrastructure for reverse transcription-quantitative PCR (RT-qPCR) or in difficult-to-access areas and developing methods with the need for less invasive sampling procedures. Therefore, the present study evaluated the performance of the direct reverse transcription loop-mediated isothermal amplification (RT-LAMP) test for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the saliva and nasal samples of asymptomatic individuals belonging to the university population. In addition, this test was also assessed for effectiveness in symptomatic individuals referred from a hospital with poor infrastructure in molecular biology and located outside the urban area. The RT-LAMP assay was compared with the results obtained from the RT-qPCR nasopharyngeal swab test, where the diagnosis was confirmed by lateral flow immunoassay test for rapid antigen detection. A total of 128 samples were analyzed, of which 43% were symptomatic positive individuals, 25% were asymptomatic positive individuals and 32% were SARS-CoV2-negative control individuals. Among positive individuals, no differences were found between the Cq values determined by RT-qPCR. A sensitivity of 96.5% and a specificity of 97.6% was reported for the detection of SARS-CoV-2 in symptomatic individuals by salivary and nasal RT-LAMP, as well as a sensitivity of 100% and a specificity of 97.6% for the detection of SARS-CoV-2 in asymptomatic individuals. These findings indicated that performance of the direct RT-LAMP test using saliva and nasal samples has high sensitivity and specificity, which in turn suggest that it is a viable and reliable alternative for use in epidemiological monitoring.

9.
Pathogens ; 12(7)2023 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-37513767

RESUMO

Despite its many advantages, a reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay has yet to be developed for canine parainfluenza virus 5 (CPIV5). In this study, a visual RT-LAMP (vRT-LAMP) assay was developed for the rapid detection of CPIV5 in clinical samples. At a constant reaction temperature of 62 °C, the assay was completed within 40 min, and the results could be directly detected with the naked eye using a hydroxynaphthol blue (HNB) metal indicator without any additional detection apparatuses. The assay specifically amplified CPIV5 RNA with a limit of detection of 10 RNA copies/reaction, which was 10-fold more sensitive than the previously reported conventional reverse-transcription polymerase chain reaction (cRT-PCR) assay and was comparable to the previously reported real-time RT-PCR (qRT-PCR) assay. In a clinical evaluation using 267 nasopharyngeal swab samples collected from hospitalized dogs with respiratory symptoms, the CPIV5 detection rate using the vRT-LAMP assay was 5.24% (14/267), which was higher than that of the cRT-PCR assay (4.49%, 12/267) and consistent with that of the qRT-PCR assay, demonstrating 100% concordance with a kappa coefficient value (95% confidence interval) of 1 (1.00-1.00). The discrepancies in the results of the assays were confirmed to be attributed to the low sensitivity of the cRT-PCR assay. Owing to the advantages of a high specificity, rapidity, and simplicity, the developed vRT-LAMP assay using an HNB metal indicator will be a valuable diagnostic tool for the detection of CPIV5 in canine clinical samples, even in resource-limited laboratories.

10.
Sens Actuators B Chem ; 392: 134085, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37304211

RESUMO

Sensitive and rapid detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been a vital goal in the ongoing COVID-19 pandemic. We present in this comprehensive work, for the first time, detailed fabrication and clinical validation of a point of care (PoC) device for rapid, onsite detection of SARS-CoV-2 using a real-time reverse-transcription loop-mediated isothermal amplification (RT-LAMP) reaction on a polymer cartridge. The PoC system, namely PATHPOD, consisting of a standalone device (weight less than 1.2 kg) and a cartridge, can perform the detection of 10 different samples and two controls in less than 50 min, which is much more rapid than the golden standard real-time reverse-transcription Polymerase Chain Reaction (RT-PCR), typically taking 16-48 h. The novel total internal reflection (TIR) scheme and the reactions inside the cartridge in the PoC device allow monitoring of the diagnostic results in real-time and onsite. The analytical sensitivity and specificity of the PoC test are comparable with the current RT-PCR, with a limit of detection (LOD) down to 30-50 viral genome copies. The robustness of the PATHPOD PoC system has been confirmed by analyzing 398 clinical samples initially examined in two hospitals in Denmark. The clinical sensitivity and specificity of these tests are discussed.

11.
Biosensors (Basel) ; 13(2)2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36831946

RESUMO

Rapid and sensitive detection of coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for early diagnosis and effective treatment. Nucleic acid testing has been considered the gold standard method for the diagnosis of COVID-19 for its high sensitivity and specificity. However, the polymerase chain reaction (PCR)-based method in the central lab requires expensive equipment and well-trained personnel, which makes it difficult to be used in resource-limited settings. It highlights the need for a sensitive and simple assay that allows potential patients to detect SARS-CoV-2 by themselves. Here, we developed an electricity-free self-testing system based on reverse transcription loop-mediated isothermal amplification (RT-LAMP) that allows for rapid and accurate detection of SARS-CoV-2. Our system employs a heating bag as the heat source, and a 3D-printed box filled with phase change material (PCM) that successfully regulates the temperature for the RT-LAMP. The colorimetric method could be completed in 40 min and the results could be read out by the naked eye. A ratiometric measurement for exact readout was also incorporated to improve the detection accuracy of the system. This self-testing system is a promising tool for point-of-care testing (POCT) that enables rapid and sensitive diagnosis of SARS-CoV-2 in the real world and will improve the current COVID-19 screening efforts for control and mitigation of the pandemic.


Assuntos
COVID-19 , Humanos , SARS-CoV-2 , Autoteste , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Sensibilidade e Especificidade , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos
12.
J Vet Med Sci ; 85(3): 329-333, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36653150

RESUMO

Severe fever with thrombocytopenia syndrome virus (SFTSV) causes lethal hemorrhagic diseases in human, cats, and dogs. Several human cases involving direct transmission of SFTSV from diseased animals have been reported. Therefore, rapid diagnosis in veterinary clinics is important for preventing animal-to-human transmission. Previously, we developed a simplified reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay for human that does not require RNA extraction for detecting the SFTSV genome. In this study, we improved the simplified RT-LAMP assay for cats by introducing a dried reaction reagent and investigated the applicability of this method for diagnosing SFTS in cats. SFTSV RNA was detected in 11 of 12 cats naturally infected with SFTSV by RT-LAMP assay using both liquid and dried reagents. The RT-LAMP assay using liquid and dried reagents was also applicable to the detection of SFTSV genes 3-4 days after challenge in cats experimentally infected with SFTSV. The minimum copy number of SFTSV genes for 100% detection using the RT-LAMP assay with liquid and dried reagents was 4.3 × 104 and 9.6 × 104 copies/mL, respectively. Although the RT-LAMP assay using the dried reagent was less sensitive than that using the liquid reagent, it was sufficiently sensitive to detect SFTSV genes in cats with acute-phase SFTS. As the simplified RT-LAMP assay using a dried reagent enables detection of SFTSV genes more readily than the assay using a liquid reagent, it is applicable for use in veterinary clinics.


Assuntos
Doenças do Gato , Doenças do Cão , Phlebovirus , Febre Grave com Síndrome de Trombocitopenia , Gatos , Animais , Humanos , Cães , Febre Grave com Síndrome de Trombocitopenia/veterinária , Indicadores e Reagentes , RNA Viral/genética , Sensibilidade e Especificidade , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/veterinária , Phlebovirus/genética
13.
Adv Mater ; 35(10): e2207138, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36398425

RESUMO

Prompt on-site diagnosis of SARS-CoV-2 with other respiratory infections will have minimized the global impact of the COVID-19 pandemic through rapid, effective management. However, no such multiplex point-of-care (POC) chip has satisfied a suitable sensitivity of gold-standard nucleic acid amplification tests (NAATs). Here, a rapid multiplexed ultrasensitive sample-to-answer loop-mediated isothermal amplification (MUSAL) chip operated by simple LED-driven photothermal amplification to detect six targets from single-swab sampling is presented. First, the MUSAL chip allows ultrafast on-chip sample preparation with ≈500-fold preconcentration at a rate of 1.2 mL min-1 . Second, the chip enables contamination-free amplification using autonomous target elution into on-chip reagents by photothermal activation. Finally, the chip accomplishes multiplexed on-chip diagnostics of SARS-CoV-2 and influenza viruses with a limit of detection (LoD) of 0.5 copies µL-1 . The rapid, ultrasensitive, cost-effective sample-to-answer chip with a multiplex capability will allow timely management of various pandemics situations that may be faced shortly.


Assuntos
COVID-19 , Orthomyxoviridae , Humanos , SARS-CoV-2 , Técnicas de Laboratório Clínico , Teste para COVID-19 , Pandemias , Sensibilidade e Especificidade , Técnicas de Amplificação de Ácido Nucleico
14.
Animals (Basel) ; 12(16)2022 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-36009664

RESUMO

Feline infectious peritonitis (FIP) is a worldwide fatal disease caused by a mutant feline coronavirus (FCoV). Simple and efficient molecular detection methods are needed. Here, sensitive, specific, rapid, and reliable colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) was developed to detect the ORF1a/1b gene of FCoV from cats with suspected FIP using neutral red as an indicator. Novel LAMP primers were specifically designed based on the gene of interest. The isothermal assay could visually detect FCoV at 58 °C for 50 min. The RT-LAMP assay was highly specific and had no cross-reactivity with other related feline viruses. The detection limit of FCoV detection by RT-LAMP was 20 fg/µL. A blind clinical test (n = 81) of the developed RT-LAMP procedure was in good agreement with the conventional PCR method. In the light of its performance specificity, sensitivity, and easy visualization, this neutral-red-based RT-LAMP approach would be a fruitful alternative molecular diagnostic tool for veterinary inspection of FCoV when combined with nucleotide sequencing or specific PCR to affirm the highly virulent FIP-associated FCoV.

15.
Biosensors (Basel) ; 12(7)2022 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-35884291

RESUMO

In this study, we developed a rotatable paper device integrating loop-mediated isothermal amplification (RT-LAMP) and a novel naked-eye readout of the RT-LAMP results using a food additive, carmoisine, for infectious pathogen detection. Hydroxyl radicals created from the reaction between CuSO4 and H2O2 were used to decolor carmoisine, which is originally red. The decolorization of carmoisine can be interrupted in the presence of DNA amplicons produced by the RT-LAMP reaction due to how DNA competitively reacts with the hydroxyl radicals to maintain the red color of the solution. In the absence of the target DNA, carmoisine is decolored, owing to its reaction with hydroxyl radicals; thus, positive and negative samples can be easily differentiated based on the color change of the solution. A rotatable paper device was fabricated to integrate the RT-LAMP reaction with carmoisine-based colorimetric detection. The rotatable paper device was successfully used to detect SARS-CoV-2 and SARS-CoV within 70 min using the naked eye. Enterococcus faecium spiked in milk was detected using the rotatable paper device. The detection limits for the SARS-CoV-2 and SARS-CoV targets were both 103 copies/µL. The rotatable paper device provides a portable and low-cost tool for detecting infectious pathogens in a resource-limited environment.


Assuntos
COVID-19 , SARS-CoV-2 , Colorimetria , Humanos , Peróxido de Hidrogênio , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Transcrição Reversa , Sensibilidade e Especificidade
16.
Front Microbiol ; 13: 932698, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35903482

RESUMO

SARS-CoV-2 is a novel coronavirus that has caused a global pandemic. To date, 504,907,616 people have been infected and developed coronavirus disease 2019 (COVID-19). A rapid and simple diagnostic method is needed to control this pandemic. In this study, a visual nucleic acid detection method combining reverse transcription loop-mediated isothermal amplification and a vertical flow visualization strip (RT-LAMP-VF) was successfully established and could detect 20 copies/µl of SARS-CoV-2 RNA transcript within 50 min at 61°C. This assay had no cross-reactivity with a variety of coronaviruses, including human coronavirus OC43, 229E, HKU1, NL63, severe acute respiratory syndrome-related coronavirus (SARSr-CoV), Middle East respiratory syndrome coronavirus (MERS-CoV), and bat coronavirus HKU4, exhibiting very high levels of diagnostic sensitivity and specificity. Most strikingly, this method can be used for detecting multiple SARS-CoV-2 variants, including the Wuhan-Hu-1 strain, Delta, and Omicron variants. Compared with the RT-qPCR method recommended by the World Health Organization (WHO), RT-LAMP-VF does not require special equipment and is easy to perform. As a result, it is more suitable for rapid screening of suspected SARS-CoV-2 samples in the field and local laboratories.

17.
Talanta ; 248: 123644, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35660994

RESUMO

Simple and accurate testing tools for SARS-CoV-2 viral RNA detection are essential for the prevention of the spread of the virus and timely governmental actions. Herein, we present a reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for the simultaneous detection of ORF1ab and N gene fragments of SARS-CoV-2 in one pot. Using two primer sets and two molecular beacon (MB) probes respectively labelled with different fluorophore, positive results were obtained with a limit of detection of 20 and 2 copies/µL for ORF1ab and N gene fragments, respectively. Moreover, the RT-LAMP based assay was applied to detect single-site differences in S genes using two one-step displacement (OSD) probes targeting wild-type and mutant (P681R mutation was chosen as model) genes. Through that, the wild type strain and P681R mutant variant were well distinguished from each other, and a preliminary observation was also made on other mutations at this site such as P681H. The proposed method has high sensitivity for quantification and high specificity for mutation differentiation. In addition, it does not require accurate sophisticated thermal cycler instrumentation and can be used in clinical settings in resource-limited regions.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Corantes Fluorescentes , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/genética , SARS-CoV-2/genética , Sensibilidade e Especificidade
18.
J Am Mosq Control Assoc ; 38(1): 7-18, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35276729

RESUMO

Eastern equine encephalitis virus (EEEV) is a highly pathogenic alphavirus that causes periodic outbreaks in the eastern USA. Mosquito abatement programs are faced with various challenges with surveillance and control of EEEV and other mosquito-borne illnesses. Environmental sampling of mosquito populations can be technically complex. Here we report the identification of biomarkers, development and validation of a colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for the detection of EEEV. Positive samples are easily visualized by a color change from pink to yellow. The assay was validated using EEEV from viral culture, experimentally spiked mosquito pools, and previously tested mosquito pools. The RT-LAMP assay detected viral titers down to approximately 10% of what would be present in a single infectious mosquito, based upon EEEV viral titers determined by previous competency studies. The RT-LAMP assay efficiently detected EEEV in combined aliquots from previously homogenized pools of mosquitoes, allowing up to 250 individual mosquitoes to be tested in a single reaction. No false positive results were obtained from RNA prepared from negative mosquito pools acquired from known and potential EEEV vectors. The colorimetric RT-LAMP assay is highly accurate, technically simple, and does not require sophisticated equipment, making it a cost-effective alternative to real time reverse transcriptase-polymerase chain reaction (RT-PCR) for vector surveillance.


Assuntos
Culicidae , Vírus da Encefalite Equina do Leste , Animais , Colorimetria , Cavalos , Técnicas de Diagnóstico Molecular , Mosquitos Vetores , Técnicas de Amplificação de Ácido Nucleico , DNA Polimerase Dirigida por RNA , Sensibilidade e Especificidade
19.
Anal Chim Acta ; 1192: 339336, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35057952

RESUMO

Early and accurate diagnosis of viruses is critical for control of the pandemic. CRISPR/Cas-based detection of nucleic acid is an emerging technology for molecular diagnostics, and has been applied for virus detection. Though these methods have excellent sensitivity and specificity, most of them were not able to measure the quantity of virus. We here developed a droplet digital reverse transcription loop-mediated isothermal amplification (RT-LAMP) enhanced Cas12b-based RNA detection platform (RECD), for quantitative detection of viral RNA. CRISPR/Cas12b, which is more thermally stable than other family members in CRISPR systems, is combined with digital RT-LAMP. Due to the innate characteristic of digital format detection and CRISPR/Cas system, droplet digital RECD (ddRECD) assay enables absolute quantification of viral RNA, with single-molecule sensitivity. We expect the ddRECD assay will be a powerful tool for molecular diagnostics.


Assuntos
Ácidos Nucleicos , RNA Viral , Sistemas CRISPR-Cas , RNA Viral/genética , Sensibilidade e Especificidade
20.
Anal Bioanal Chem ; 414(10): 3177-3186, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35044487

RESUMO

The degree of detrimental effects inflicted on mankind by the COVID-19 pandemic increased the need to develop ASSURED (Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, and Deliverable) POCT (point of care testing) to overcome the current and any future pandemics. Much effort in research and development is currently advancing the progress to overcome the diagnostic pressure built up by emerging new pathogens. LAMP (loop-mediated isothermal amplification) is a well-researched isothermal technique for specific nucleic acid amplification which can be combined with a highly sensitive immunochromatographic readout via lateral flow assays (LFA). Here we discuss LAMP-LFA robustness, sensitivity, and specificity for SARS-CoV-2 N-gene detection in cDNA and clinical swab-extracted RNA samples. The LFA readout is designed to produce highly specific results by incorporation of biotin and FITC labels to 11-dUTP and LF (loop forming forward) primer, respectively. The LAMP-LFA assay was established using cDNA for N-gene with an accuracy of 95.65%. To validate the study, 82 SARS-CoV-2-positive RNA samples were tested. Reverse transcriptase (RT)-LAMP-LFA was positive for the RNA samples with an accuracy of 81.66%; SARS-CoV-2 viral RNA was detected by RT-LAMP-LFA for as low as CT-33. Our method reduced the detection time to 15 min and indicates therefore that RT-LAMP in combination with LFA represents a promising nucleic acid biosensing POCT platform that combines with smartphone based semi-quantitative data analysis.


Assuntos
COVID-19 , Ácidos Nucleicos , Biotina , COVID-19/diagnóstico , Humanos , Pandemias , SARS-CoV-2/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA