Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 616
Filtrar
1.
Dig Endosc ; 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39188169

RESUMO

Since self-expanding metal stents (SEMS) were first introduced in acute colon cancer obstruction, the increased rate of primary anastomosis and improved quality of life following SEMS placement have been clearly shown. However, it was demonstrated that SEMS are associated with higher recurrence rates. Although several trials have shown that overall and disease-free survival in patients following SEMS placement is similar with patients undergoing emergency surgery, obstruction and a high incidence of recurrence imposed many concerns. The optimal time interval from SEMS to surgery is still a matter of debate. Some studies have recommended a time interval of ~2 weeks between SEMS insertion and elective surgery. A prolonged interval of time from SEMS insertion to elective surgery and the administration of neoadjuvant chemotherapy (NAC) has been proposed. SEMS-NAC might have advantages for improving the surgical and long-term survival outcomes of patients with acute colon cancer obstruction, which is an optional approach in the management of acute colon cancer obstruction.

2.
Bioengineering (Basel) ; 11(8)2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39199713

RESUMO

The Eustachian tube (ET) is a bottleneck when it comes to middle ear (ME) health. If its function is impaired, this can lead to serious consequences for the patient, such as hearing problems or deafness. Therefore, this study investigated a tapered nitinol stent (3-5 mm × 14 mm) for the human ET as a potential new permanent treatment for chronic Eustachian tube dysfunction (ETD) and thus ME ventilation disorders. The self-expanding stent was inserted unilaterally into the ET of 24 sheep with observation periods of 3, 6, and 12 months. Local tissue effects and the safety of the stent insertion were analyzed based on regular endoscopic checks, weekly tympanometry measurements, final imaging, and histological examinations. The animals showed no stent-related health restrictions. However, the individual anatomy and stenting procedure had an influence on the results. The tissue reaction in the endoscopic examinations was mild even though no concomitant antibiotics were administered. After all three monitoring periods, stented ETs had a significantly larger ET lumen than the non-stented contralateral ETs. However, tissue growth was detected in the stent. Overall, the first long-term study on an ET stent showed that the tapered ET stent could be a promising treatment option for ETD.

3.
ACG Case Rep J ; 11(8): e01473, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39176220

RESUMO

Portal cavernoma cholangiopathy refers to changes in the intrahepatic and extrahepatic biliary ducts in patients with extrahepatic portal venous obstruction. Spontaneous hemobilia in the setting of portal cavernoma cholangiopathy is extremely rare, and it poses diagnostic as well as therapeutic challenge. Here, we report the case of a 10-year-old girl with extrahepatic portal venous obstruction, who presented with hemobilia. Computed tomography angiography of abdomen and endoscopic ultrasound confirmed the presence of pericholedochal, paracholedochal, and intracholedochal varices. Hemostasis was achieved with the placement of a fully covered self-expanding metallic stent into the common bile duct. Fully covered self-expanding metallic stent is safe and effective for control of bleeding in children presenting with hemobilia.

4.
J Soc Cardiovasc Angiogr Interv ; 3(7): 102146, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39131997

RESUMO

Background: The choice of transcatheter aortic valve replacement (TAVR) prosthesis is crucial in optimizing short- and long-term outcomes. The objective of this study was to conduct a meta-analysis comparing outcomes of third-generation balloon-expandable valves (BEV) vs self-expanding valves (SEV). Methods: Electronic databases were searched from inception to June 2023 for studies comparing third-generation BEV vs SEV. Primary outcome was all-cause mortality. Secondary outcomes included clinical and hemodynamic end points. Random-effects models were used to calculate pooled odds ratios (ORs) or weighted mean differences (WMDs). Results: The meta-analysis included 16 studies and 10,174 patients (BEV, 5753 and SEV, 4421). There were no significant differences in 1-year all-cause mortality (OR, 1.15; 95% CI, 0.89-1.48) between third-generation BEV vs SEV. TAVR with third generation BEV was associated with a significantly lower risk of TIA/stroke (OR, 0.62; 95% CI, 0.44-0.87), permanent pacemaker implantation (OR, 0.55; 95% CI, 0.44-0.70), and ≥moderate paravalvular leak (PVL, OR, 0.43; 95% CI, 0.25-0.75), and higher risk of ≥moderate patient-prosthesis mismatch (OR, 3.76; 95% CI, 2.33-6.05), higher mean gradient (WMD, 4.35; 95% CI, 3.63-5.08), and smaller effective orifice area (WMD, -0.30; 95% CI, -0.37 to -0.23), compared with SEV. Conclusion: In this meta-analysis, TAVR with third-generation BEV vs SEV was associated with similar all-cause mortality, lower risk of TIA/stroke, permanent pacemaker implantation, and ≥moderate PVL, but higher risk of ≥moderate patient-prosthesis mismatch, higher mean gradient, and smaller effective orifice area. Large, adequately powered randomized trials are needed to evaluate long-term outcomes of TAVR with latest generations of BEV vs SEV.

5.
J Anus Rectum Colon ; 8(3): 195-203, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39086875

RESUMO

Objectives: To clarify whether self-expandable metallic stent (SEMS) placement for obstructive colorectal cancer (CRC) increases perineural invasion (PNI), thereby worsening the prognosis. Methods: In total, 1022 patients with pathological T3 or T4 colon or rectosigmoid cancer who underwent resection were retrospectively reviewed. The study patients were divided into a no obstruction group (n=693), obstruction without stent group (n=251), and obstruction with stent group (n=78), and factors demonstrating an independent association with PNI, the difference in PNI incidence and severity between groups, and the association between PNI and the duration from SEMS placement to surgery were investigated. Survival analysis was performed for each group. Results: On multivariate analysis, SEMS placement (hazard ratio [HR]: 2.08) was independently associated with PNI whereas SEMS placement was not. PNI occurred in 39%, 45%, and 68% of the no obstruction, obstruction without stent, and obstruction with stent group, respectively. In the obstruction with stent group, the proportion of PNI was not associated with the duration from SEMS placement to surgery. Extramural PNI, an advanced form of PNI, demonstrated no increase with increasing interval. The five-year OS was 86.3%, 76.7%, and 73.1% in no obstruction, obstruction without stent, and obstruction with stent group, respectively. On multivariate analysis, obstruction was an independent risk factor of decreased OS (HR: 1.57) whereas SEMS placement was not. Conclusions: The prognosis was comparable between patients with SEMS placement and those with an obstruction who did not undergo SEMS placement, thus demonstrating that SEMS is a viable, therapeutic option for BTS.

6.
Am J Cardiol ; 229: 1-12, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39053723

RESUMO

A metanalysis of available randomized controlled trials and observational studies comparing self-expanding (SE) and balloon-expandable (BE) bioprostheses in patients with small aortic annulus and aortic stenosis for short- and midterm hemodynamic and clinical outcomes was performed. A total of 21 studies with a total 8,647 patients (SE: n = 4,336 patients vs BE: n = 4,311 patients) were included. SE bioprostheses had a lower postoperative mean gradient at 30 days (Mean Difference [MD] -5.16, 95% confidence interval [CI] 4.7 to 5.5, p <0.001) and at 1 year (MD -6.6, 95%CI 6.1 to 7.03, p <0.001), with a larger indexed effective orifice area (0.17, 95% CI 0.13 to 0.22, p <0.001 and 0.17, 95% CI 0.08 to 0.27, p <0.001) at both time intervals. BE bioprostheses had a higher risk of 30-day and 1-year severe prosthesis-patient mismatch (risk ratio [RR] 1.07, 95% CI 1.04 to 1.09, p <0.001; RR 1.07, 95% CI 1.04 to 1.11, p <0.001). The 30-day and 1 year paravalvular leaks (RR 0.99, 95% CI 0.98 to 0.99, p <0.001; RR 0.89, 95% CI 0.82 to 0.95, p <0.001) and permanent pacemaker implantation (RR 0.97, 95% CI 0.94 to 0.99, p 0.01, I2 = 40%,) were lower in the BE group. BE bioprostheses were associated with a lower risk of in-hospital stroke (RR 0.99, 95% CI 0.98 to 1, p = 0.01). In conclusion, in patients with small aortic annulus and aortic stenosis, SE bioprostheses have superior hemodynamic performance but higher rates of paravalvular leak, permanent pacemaker implantation, and in-hospital stroke. BE bioprostheses were associated with a higher risk of severe prosthesis-patient mismatch.

7.
Sci Rep ; 14(1): 17554, 2024 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-39080364

RESUMO

Repositionable self-expanding valves allow for repositioning during deployment to achieve optimal valve placement. However, the risk of brain injury associated with repositioning, as detected by diffusion-weighted magnetic resonance imaging (DW-MRI), is unknown. Consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with repositionable self-expanding valves and receiving DW-MRI before and within 7 days post-TAVR procedure were included. The primary outcomes were incidence, number, total volume, and volume per lesion of the cerebral ischemic lesion in DW-MRI after TAVR. Univariate and multivariate logistic regression assessed the association between repositioning and bigger total lesion volume (> 1 cm3 or > 0.5 cm3). Negative binomial regressions were performed to explore the association between repositioning and number of lesions. A propensity score matching was performed to adjust the potential confounders. Moreover, inverse probability of treatment weighted regression model with nonstabilized weights was used as sensitivity analysis. Among 243 included patients, repositioning was performed in 116 (47.7%) patients. The incidence of overt stroke (1.7% vs. 1.6%, p = 0.927) and silent stroke (86.2% vs. 85.8%, p = 0.932) were comparable between two groups. However, the number of new lesions (5.0 [2.0-9.0] vs. 3.0 [2.0-6.0], p = 0.048), and total lesion volume (275.0 [90.0-947.5] mm3 vs. 180.0 [50.0-440.0] mm3, p = 0.022) were significantly higher in the repositioned group. Moreover, the proportion of patients with lesion size greater than 0.5 cm3 was higher in the repositioned group (37.9% vs. 22.0%, p = 0.007). The similar results were observed after propensity score matching. In both multivariate regression model and sensitivity analysis, the repositioning was the independent predictor of number of lesions and bigger total lesion volume after TAVR. The utilization of the repositioning feature may increase the number and volume of silent brain infarcts in DW-MRI in patients who underwent TAVR. (Transcatheter Aortic Valve Replacement Single Center Registry in Chinese Population [TORCH]; NCT02803294).


Assuntos
Lesões Encefálicas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Lesões Encefálicas/etiologia , Lesões Encefálicas/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Próteses Valvulares Cardíacas/efeitos adversos , Incidência , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
8.
Ann Med Surg (Lond) ; 86(7): 4060-4074, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38989187

RESUMO

Background: Aortic stenosis (AS) is a common heart condition categorized into congenital and acquired forms. Transcatheter aortic valve replacement (TAVR) is an innovative method for AS management, and two valve types, self-expanding valves (SEV) and balloon-expandable valves (BEV), are used in TAVR. The objective of this study is to compare the clinical outcomes associated with balloon-expandable and self-expandable valves in transcatheter aortic valve replacement. Methods: The researchers conducted a comprehensive meta-analysis following PRISMA guidelines and AMSTAR-2 tool. The methodology involved a systematic literature search, strict eligibility criteria, unbiased study selection, meticulous data extraction, quality assessment, and rigorous statistical analysis. Results: Our analysis included twenty-six papers and 26 553 patients. BEV exhibited significant advantages over SEV in overall mortality across 21 studies, particularly in perioperative and 30-day assessments. However, no substantial disparities emerged between the two valve types in stroke incidence. BEV demonstrated notable benefits in reducing hospitalization rates across 6 studies and significantly fewer instances of permanent pacemaker implantations across 19 studies, particularly evident in the perioperative setting. Other secondary outcomes like bleeding, acute kidney injury, and myocardial infarction showcased non-significant differences between BEV and SEV. Conclusion: The analysis indicates that BEV may offer benefits in specific aspects of TAVR outcomes, but further research is needed to fully understand the factors influencing patient outcomes and mortality in TAVR procedures.

9.
Tech Coloproctol ; 28(1): 85, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39028327

RESUMO

INTRODUCTION: Patients presenting with large bowel obstruction (LBO) frequently undergo emergency surgery that is associated with significant morbidity. In malignant LBO, endoscopic approaches with placement is a self-expanding metal stent (SEMS), have been proposed to prevent emergency surgery and act as a bridge to an elective procedure-with the intention of avoiding a stoma and reducing morbidity. This systematic review aims to assess the quality and outcomes of data available on the use of SEMS in benign causes of colonic obstruction. METHODS: This systematic review was performed using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, and the protocol was registered on Prospero (ID: CRD42021239363). PUBMED, MEDLINE, HMIC, CINAHL, AMED, EMBASE, APA and Cochrane databases were searched. Studies were assessed for quality utilising the MINORS criteria. Pooled odds ratios with 95% confidence intervals (95% CI) were calculated using random effects models. RESULTS: Sixteen studies were included for analysis. 300 patients were included with an average age of 68, and a male predominance of 57%. The quality of the papers included were at risk of bias. The pooled rate of technical success of procedure was 94.4% (95% CI 90.5-96.8%) The pooled rate of clinical success was 77.6% (95% CI: 66.6-85.7%). Adverse effects were low, with perforation 8.8% (4.5-16.6%), recurrence 26.5% (17.2-38.5%) and stent migration 22.5% (14.1-33.8%). DISCUSSION: This systematic review demonstrated that SEMS for benign colonic obstruction can be a safe and successful procedure. The utilisation of SEMS in malignant disease as a bridge to surgery has been well documented. Whilst the limitations of the data interpreted are appreciated, we postulate that SEMS could be utilised to decompress patients acutely and allow pre-operative optimisation, leading to a more elective surgery with less subsequent morbidity.


Assuntos
Doenças do Colo , Obstrução Intestinal , Stents Metálicos Autoexpansíveis , Humanos , Obstrução Intestinal/etiologia , Obstrução Intestinal/cirurgia , Doenças do Colo/cirurgia , Doenças do Colo/etiologia , Feminino , Masculino , Resultado do Tratamento , Idoso , Pessoa de Meia-Idade
10.
Eur J Surg Oncol ; 50(10): 108539, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-39067304

RESUMO

INTRODUCTION: Colon cancer obstruction is one of the most serious conditions in colorectal surgery. However, the use of self-expanding metallic stent (SEMS) has made it possible to avoid emergency surgery and stoma creation, therefore enabling minimally invasive surgery and one-stage operation. In this study, we aimed to investigate whether there is an optimal interval from SEMS to surgery for the best long-term oncologic outcomes. METHODS: Obstructive colon cancer patients treated with SEMS insertion and received surgery were included in the study. Patient data were retrospectively reviewed in prospectively collected data. Using the ROC curve, the optimal interval to surgery after SEMS insertion was 10 days; the patients were divided into the early surgery group (≤10 days, ES) and the late surgery group (>10 days, LS). Factors contributing to the 5-year disease-free survival (DFS) and overall survival (OS) were analyzed. RESULTS: 83 patients were included in this study. Eight patients (9.6 %) had SEMS insertion failure, with 3 perforations and 5 failed expansions. There were no differences between the ES group and the LS group in terms of pathologic characteristics, incidence of stoma creation, and adjuvant chemotherapy. Twenty-six patients (31.3 %) had recurrences; local (Arnarson et al., 2023) [6], peritoneal seeding (Lee et al., 2013) [8], liver (Ho et al., 2017) [11], lung [7], bone (van Hooft et al., 2020) [2], and abdominal wall metastasis (Chen and Sheen-Chen, 2000) [1]. The 5-year DFS rate was significantly better in the ES group than the LS group (74.3 % vs. 55.01 %; p = 0.0394). The 5-year OS was slightly better in the ES group than the LS group (76.11 % vs. 58.75 %; p = 0.0901). In univariable analysis, the ES group showed a lower risk of recurrence than the LS group (OR: 0.447 [0.204-0.984], p = 0.0455), but this was not reproduced in the multivariable analysis. CONCLUSION: This study has shown that the long-term oncologic outcomes were better in patients who received surgery after SEMS within 10 days. Hence, we propose with caution that elective surgery might be suggested to take place within 10 days from SEMS insertion for better oncologic outcomes.

11.
Artigo em Inglês | MEDLINE | ID: mdl-38955627

RESUMO

BACKGROUND: There is limited data on cardiac output in patients with small aortic annuli undergoing trans-catheter aortic valve implantation (TAVI) according to the implanted platform of balloon-expandable (BEV) compared to self-expanding valves (SEV). METHODS: This is a retrospective analysis of consecutive patients with severe aortic stenosis and small annuli who underwent successful TAVI. Cardiac output was measured using echocardiography within 4 weeks following TAVI. Data were recorded and analysed by an experienced operator who was not aware of the type of the implanted valve. RESULTS: 138 patients were included in the analysis, of whom 57 % underwent TAVI with BEV. Clinical and echocardiographic characteristics were comparable between the two platforms, except for more frequent previous cardiac surgery and smaller indexed aortic valve in the BEV group. There was no relationship between computed tomography-derived aortic annulus area and cardiac output post TAVI. When compared to patients who underwent TAVI with BEV, those with SEV had larger cardiac output [mean difference - 0.50 l/min, 95 % CI (-0.99, -0.01)] and cardiac index [mean difference - 0.20 l/min/m2, 95 % CI (-0.47, 0.07)], although the latter did not reach statistical significance. Unlike patients with small body surface area, in those with large body surface area both cardiac output and cardiac index were statistically larger in patients who underwent SEV compared to BEV. CONCLUSION: Cardiac output, as measured by echocardiography, was larger in patients with small annuli who underwent TAVI procedure with SEV compared to BEV. Such difference was more evident in patients with large body surface area.

12.
Therap Adv Gastroenterol ; 17: 17562848241248219, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38855340

RESUMO

Background: The symptoms of gastric outlet obstruction have traditionally been managed surgically or endoscopically. Enteral stenting (ES) is a less invasive endoscopic treatment strategy for this condition. Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) has recently become a potential alternative technique. Objectives: We conducted a systematic review and meta-analysis of the effectiveness and safety profile of EUS-GE compared with ES. Design: Meta-analysis and systematic review. Data sources and methods: We searched multiple databases from inception to August 2023 to identify studies that reported the effectiveness and safety of EUS-GE compared with ES. The outcomes of technical success, clinical success, and adverse events (AEs) were evaluated. Pooled proportions were calculated using both fixed and random effects models. Results: We included 13 studies with 1762 patients in our final analysis. The pooled rates of technical success for EUS-GE were 95.59% [95% confidence interval (CI), 94.01-97.44, I 2 = 32] and 97.96% (95% CI, 96.06-99.25, I 2 = 63) for ES. The pooled rate of clinical success for EUS-GE was 93.62% (95% CI, 90.76-95.98, I 2 = 54) while for ES it was lower at 85.57% (95% CI, 79.63-90.63, I 2 = 81). The pooled odds ratio (OR) of clinical success was higher for EUS-GE compared to ES at 2.71 (95% CI, 1.87-3.93). The pooled OR of clinical success for EUS-GE was higher compared to ES at 2.72 (95% CI, 1.86-3.97, I 2 = 0). The pooled rates of re-intervention for EUS-GE were lower at 3.77% (95% CI, 1.77-6.46, I 2 = 44) compared with ES, which was 25.13% (95% CI, 18.96-31.85, I 2 = 69). The pooled OR of the rate of re-intervention in the ES group was higher at 7.96 (95% CI, 4.41-14.38, I 2 = 13). Overall, the pooled rate for AEs for EUS-GE was 8.97% (95% CI, 6.88-11.30, I 2 = 15), whereas that for ES was 19.63% (95% CI, 11.75-28.94, I 2 = 89). Conclusion: EUS-GE and ES are comparable in terms of their technical effectiveness. However, EUS-GE has demonstrated improved clinical effectiveness, a lower need for re-intervention, and a better safety profile compared to ES for palliation of gastric outlet obstruction.

13.
Artigo em Inglês | MEDLINE | ID: mdl-38871537

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry. METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure. RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus. CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.

14.
Front Physiol ; 15: 1407215, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38903911

RESUMO

Transcatheter aortic valve replacement (TAVR) is a minimally invasive interventional solution for treating aortic stenosis. The complex post-TAVR complications are associated with the type of valve implanted and the position of the implantation. The study aimed to establish a rapid numerical research method for TAVR to assess the performance differences of self-expanding valves released at various positions. It also aimed to calculate the risks of postoperative paravalvular leak and atrioventricular conduction block, comparing these risks to clinical outcomes to verify the method's effectiveness and accuracy. Based on medical images, six cases were established, including the aortic wall, native valve and calcification; one with a bicuspid aortic valve and five with tricuspid aortic valves. The parameters for the stent materials used by the patients were customized. High strain in the contact area between the stent and the valve annulus may lead to atrioventricular conduction block. Postoperatively, the self-expanding valve maintained a circular cross-section, reducing the risk of paravalvular leak and demonstrating favorable hemodynamic characteristics, consistent with clinical observations. The outcomes of the six simulations showed no significant difference in valve frame morphology or paravalvular leak risk compared to clinical results, thereby validating the numerical simulation process proposed for quickly selecting valve models and optimal release positions, aiding in TAVR preoperative planning based on patients'geometric characteristics.

15.
JACC Case Rep ; 29(13): 102388, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38912321

RESUMO

An 82-year-old patient experienced symptomatic intra-prosthetic aortic regurgitation 5 years after self-expandable transcatheter heart valve (THV) implantation. Redo-transcatheter aortic valve replacement was initially considered at high risk of coronary obstruction. Using a systematic computed tomography-based approach planning a low implantation with a SAPIEN 3 Ultra THV, we effectively mitigated risks.

16.
Surg Today ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858263

RESUMO

PURPOSE: The prognostic value of the lymphocyte-to-monocyte (LMR) ratio has been reported for various cancers, including colorectal cancer (CRC). The insertion of colonic stents is considered effective for patients with surgically indicated obstructive CRC, but their LMR can vary depending on factors such as inflammation associated with stent dilation and improvement of obstructive colitis. However, the usefulness of the LMR in patients with obstructive CRC and colonic stents and the optimal timing for its measurement remain unclear. We conducted this study to investigate the relationship between the pre-stent LMR and the mid-term prognosis of patients with obstructive CRC and stents as a bridge to surgery (BTS). METHODS: The subjects of this retrospective multicenter study were 175 patients with pathological stage 2 or 3 CRC. Patients were divided into a low pre-stent LMR group (n = 87) and a high pre-stent LMR group (n = 83). RESULTS: Only 3-year relapse-free survival differed significantly between the low and high pre-stent LMR groups (39.9% vs. 63.6%, respectively; p = 0.015). The pre-stent LMR represented a prognostic factor for relapse-free survival in multivariate analyses (hazard ratio 2.052, 95% confidence interval 1.242-3.389; p = 0.005), but not for overall survival. CONCLUSIONS: A low pre-stent LMR is a prognostic factor for postoperative recurrence in patients with obstructive CRC and a colonic stent as a BTS.

17.
J Clin Med ; 13(11)2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38892875

RESUMO

Background: The primary objective of this study was to evaluate the initial experience in Germany with the Meril Myval™ (MM) transcatheter heart valve (THV) system for the treatment of severe symptomatic aortic valve stenosis. The MM THV is a novel balloon-expandable valve with an expanded sizing matrix. Contemporary patients undergoing TAVI with the established Edwards Sapien™ (ES) THV served as the comparator group. Methods: Between 1st March and 31 August 2020 a total of 134 patients (33% female, 80.1 ± 6.7 years; EuroScore II 4.7 ± 4.8) underwent TAVI with an MM (95% transfemoral) for severe aortic stenosis at six German tertiary care centers. Results: Correct positioning of the THV was achieved in 98.5% (n = 132). Mean aortic gradients (MPG) were reduced from 42 ± 14 mmHg to 11 ± 5 mmHg. Mild postprocedural paravalvular leak (PVL) was observed in 62% (n = 82) patients, whereas only one patient had more than mild PVL. New permanent pacemaker implantation (PPI) was indicated in 15 patients (11%). Major vascular complications occurred in 6.7% (n = 9) patients. The in-hospital combined incidence of all-cause death and stroke was 4.5% (n = 6). In the comparator group that included 268 patients, the 30-day incidences of PPI, major vascular complications, and the composite of all-cause death and stroke were 16%, 1.9%, and 7.1%, respectively; MPGs were reduced from 44 ± 15 mmHg to 12.8 ± 4.6 mmHg and the more than mild PVL occurred in 0.7%. Conclusions: The MM is a promising novel THV system, with performance comparable to the established ES THVs. These findings await confirmation by ongoing randomized trials.

18.
Pancreatology ; 24(4): 608-615, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749803

RESUMO

BACKGROUND: Acute cholangitis (AC) is a common complication of pancreatic ductal adenocarcinoma (PDAC). Herein, we evaluated outcomes after the first AC episode and predictors of mortality and AC recurrence in patients with stage IV PDAC. METHODS: We conducted a single-center, retrospective observational study using institutional databases. Clinical data and outcomes for patients with stage IV PDAC and at least one documented episode of AC, were assessed. Overall survival (OS) was estimated using the Kaplan-Meier method, and Cox regression model was employed to identify predictors of AC recurrence and mortality. RESULTS: One hundred and twenty-four patients with stage IV PDAC and AC identified between January 01, 2014 and October 31, 2020 were included. Median OS after first episode of AC was 4.1 months (95 % CI, 4.0-5.5), and 30-day, 6, and 12-month survival was 86.2 % (95 % CI, 80.3-92.5), 37 % (95 % CI, 29.3-46.6 %) and 18.9 % (95 % CI, 13.1-27.3 %), respectively. Primary tumor in pancreatic body/tail (HR 2.29, 95 % CI: 1.26 to 4.18, p = 0.011), concomitant metastases to liver and other sites (HR 1.96, 95 % CI: 1.16 to 3.31, p = 0.003) and grade 3 AC (HR 2.26, 95 % CI: 1.45 to 3.52, p < 0.001), predicted worse outcomes. Intensive care unit admission, sepsis, systemic therapy, treatment regimen, and time to intervention did not predict survival or risk of recurrence of AC. CONCLUSIONS: AC confers significant morbidity and mortality in advanced PDAC. Worse outcomes are associated with higher grade AC, primary tumor location in pancreatic body/tail, and metastases to liver and other sites.


Assuntos
Colangite , Neoplasias Pancreáticas , Humanos , Colangite/complicações , Colangite/mortalidade , Masculino , Feminino , Neoplasias Pancreáticas/mortalidade , Neoplasias Pancreáticas/complicações , Neoplasias Pancreáticas/patologia , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Prognóstico , Estadiamento de Neoplasias , Carcinoma Ductal Pancreático/mortalidade , Carcinoma Ductal Pancreático/complicações , Carcinoma Ductal Pancreático/patologia , Idoso de 80 Anos ou mais , Adenocarcinoma/mortalidade , Adenocarcinoma/complicações , Adenocarcinoma/patologia , Doença Aguda , Fatores de Risco
19.
Int J Cardiol ; 410: 132218, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38815673

RESUMO

BACKGROUND: The possibility to resheath some transcatheter heart valves (THV) facilitates the optimization of self-expandable devices implantation. However, resheating manoeuvres (expecially when repeated) increase the interaction between the transcatheter prosthesis and the patient's tissues potentially causing side-effects. AIMS: To assess the clinical outcomes of resheathing at midterm follow-up with a focus on the safety of multiple resheathing. METHODS: This retrospective observational study included all consecutive patients who underwent TAVI with a self-expandable supra-annular THV between December 2018 and December 2022. Primary endpoint was a composite of cardiovascular (CV) mortality, neurological events, non-fatal acute myocardial infarction and CV rehospitalizations. All clinical endpoints were assessed according to VARC-3 criteria. RESULTS: 469 TAVI procedures with self-expandable supra-annular THV were included in the study. The attempt to resheath and the resheath manoeuvres number was prospectively recorded into an electronic database. Resheating was attempted in 253 (53.9%) cases; 1, 2 and ≥ 3 resheathing were performed in respectively 122 (26.0%), 63 (13.4%) and 68 (14.5%) procedures. At a median follow-up of 640 days (interquartile range 340-1033 days), the incidence of the primary endpoint did not differ between 0 vs. ≥1 (22.7 vs. 26.1%, LogRank p = 0.584) and < 3 vs. ≥3 resheathing groups (24.2 vs. 26.5% LogRank p = 0.963). Furthermore, no significant differences in the primary endpoint were observed between 0, 1-2 and ≥ 3 resheathing (p = 0.84). CONCLUSIONS: Our study found that resheathing of self-expandable THVs during TAVI did not result in worse clinical outcomes compared with no resheathing at mid-term follow-up. These results are independent from the number of resheathing, underling the safety of multiple resheathing in terms of peri-procedural and mid-term outcome. CONDENSED ABSTRACT: In this retrospective observational study of 469 patients undergoing transcatheter aortic valve implantation (TAVI) for symptomatic severe aortic stenosis with self-expanding valves, we investigated the influence of resheathing on mid-term clinical outcomes. Specifically, we focused on the safety of multiple resheathing procedures. Our findings revealed no significant impact of resheathing on medium-term outcomes. The primary endpoint, a composite of cardiovascular mortality, neurological events, non-fatal acute myocardial infarction, and cardiovascular rehospitalizations, did not show statistically significant differences between no resheathing, single resheathing and multiple resheathing groups. Our study suggests that resheathing, even when performed multiple times, does not appear to significantly affect clinical outcomes at mid-term follow-up.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Masculino , Feminino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Idoso , Estenose da Valva Aórtica/cirurgia , Seguimentos , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
20.
Catheter Cardiovasc Interv ; 103(7): 1093-1100, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38690931

RESUMO

BACKGROUND: As compared to treatment of aortic stenosis (AS), transcatheter aortic valve replacement (TAVR) using the commercially available valves to treat pure aortic regurgitation (PAR) has a lower device success rate and higher complication rates. AIMS: The study compared the acute results between TAVR using a novel noncoronary sinus pivot implantation (NCPI) method and that using the conventional method, aiming to explore a more optimized and effective operation method for TAVR in PAR. METHODS: PAR patients who underwent TAVR with self-expanding valves in our center from September 2021 to September 2023 were enrolled were divided into the NCPI (group A, N = 16) and conventional method (group B, N = 39) groups. We analyzed the pre-operative evaluation parameters and procedural and postoperative data of the two subgroups. RESULTS: The total patients' mean age was 71.2 ± 8.7 years and most were male (61.8%), with a mean Society of Thoracic Surgeons score of 3.4 ± 1.9%. The device success rate of groups A and B was 100% and 71.8%, respectively. In group B, 48.7% had major adverse cardiac events (MACE); 46.2% patients had permanent pacemaker implantation or valve in valve implantation. None had MACE in group A. The noncoronary sinus implantation depth in NCPI was -1.1 + 1.0 and 4.2 + 3.7 mm in groups A and B (p < 0.001), respectively. CONCLUSIONS: TAVR with a self-expanding valve using the NCPI method had a higher procedure success rate and dramatically low complications than that using the conventional method in PAR patients.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Recuperação de Função Fisiológica , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Tempo , Fatores de Risco , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Hemodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA