Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 152
Filtrar
1.
World J Gastrointest Surg ; 16(8): 2546-2554, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39220077

RESUMO

BACKGROUND: Hepatocellular carcinoma (HCC) recurrence is highly correlated with increased mortality. Microvascular invasion (MVI) is indicative of aggressive tumor biology in HCC. AIM: To construct an artificial neural network (ANN) capable of accurately predicting MVI presence in HCC using magnetic resonance imaging. METHODS: This study included 255 patients with HCC with tumors < 3 cm. Radiologists annotated the tumors on the T1-weighted plain MR images. Subsequently, a three-layer ANN was constructed using image features as inputs to predict MVI status in patients with HCC. Postoperative pathological examination is considered the gold standard for determining MVI. Receiver operating characteristic analysis was used to evaluate the effectiveness of the algorithm. RESULTS: Using the bagging strategy to vote for 50 classifier classification results, a prediction model yielded an area under the curve (AUC) of 0.79. Moreover, correlation analysis revealed that alpha-fetoprotein values and tumor volume were not significantly correlated with the occurrence of MVI, whereas tumor sphericity was significantly correlated with MVI (P < 0.01). CONCLUSION: Analysis of variable correlations regarding MVI in tumors with diameters < 3 cm should prioritize tumor sphericity. The ANN model demonstrated strong predictive MVI for patients with HCC (AUC = 0.79).

2.
J Clin Med ; 13(15)2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39124709

RESUMO

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia associated with significant morbidity and mortality. Managing risk of stroke and AF burden are pillars of AF management. Atrial geometry has long been recognized as a useful measure in achieving these goals. However, traditional diagnostic approaches often overlook the complex spatial dynamics of the atria. This review explores the emerging role of three-dimensional (3D) atrial geometry in the evaluation and management of AF. Advancements in imaging technologies and computational modeling have enabled detailed reconstructions of atrial anatomy, providing insights into the pathophysiology of AF that were previously unattainable. We examine current methodologies for interpreting 3D atrial data, including qualitative, basic quantitative, global quantitative, and statistical shape modeling approaches. We discuss their integration into clinical practice, highlighting potential benefits such as personalized treatment strategies, improved outcome prediction, and informed treatment approaches. Additionally, we discuss the challenges and limitations associated with current approaches, including technical constraints and variable interpretations, and propose future directions for research and clinical applications. This comprehensive review underscores the transformative potential of leveraging 3D atrial geometry in the evaluation and management of AF, advocating for its broader adoption in clinical practice.

3.
J Am Heart Assoc ; 13(17): e032169, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39189479

RESUMO

BACKGROUND: Adverse left ventricular remodeling is a significant cardiovascular predictor for patients with coronary artery disease and preserved left ventricular ejection fraction (LVEF). However, the remodeling indexes reflecting left ventricular spherization by myocardial perfusion imaging are underexplored. METHODS AND RESULTS: 727 patients (mean age 59.8±13.5 years, 329 women) diagnosed or suspected coronary artery disease with preserved LVEF who underwent resting myocardial perfusion imaging were retrospectively enrolled. The myocardial perfusion imaging findings including the total perfusion deficit and sphericity indexes (shape index (SI) and eccentricity index (EI) obtained from gated (QGS) and non-gated (QPS) images) were collected. Major adverse cardiovascular events (MACE) were followed up for 45.1±22.0 months. All patients were divided into 4 subgroups based on total perfusion deficit at 10% and LVEF at 65%. Univariable comparative analyses were performed in 5 cohorts (all patients and 4 subgroups). Patients who experienced MACE displayed higher SI and/or lower EI (all P<0.05). Kaplan-Meier survival analyses suggested significant differences for SIQPS in all 5 cohorts, for EIQPS and EIQGS in 4 cohorts, and for end-systolic and end-diastolic SIQGS in 3 cohorts (all P<0.05). Multivariate Cox analysis showed that abnormal SI and EI remained statistically significant predictors for MACE after adjusting for total perfusion deficit, LVEF, and other confounding factors. CONCLUSIONS: For patients diagnosed or suspected of coronary artery disease with preserved or supra-normal LVEF, resting sphericity indexes by myocardial perfusion imaging displayed incremental long-term prognostic value. Among these indicators, SIQPS is particularly promising across different perfusion or preserved functional conditions.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Volume Sistólico , Função Ventricular Esquerda , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/diagnóstico por imagem , Volume Sistólico/fisiologia , Imagem de Perfusão do Miocárdio/métodos , Estudos Retrospectivos , Prognóstico , Idoso , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia , Valor Preditivo dos Testes , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem
4.
World J Orthop ; 15(8): 754-763, 2024 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-39165879

RESUMO

BACKGROUND: The sphericity of the femoral head is a metric used to evaluate hip pathologies and is associated with the development of osteoarthritis and femoral-acetabular impingement. AIM: To analyze the three-dimensional asphericity of the femoral head of asymptomatic pediatric hips. We hypothesized that femoral head asphericity will vary significantly between male and female pediatric hips and increase with age in both sexes. METHODS: Computed tomography scans were obtained on 158 children and adolescents from a single institution in the United States (8-18 years; 50% male) without hip pain. Proximal femoral measurements including the femoral head diameter, femoral head volume, residual volume, asphericity index, and local diameter difference were used to evaluate femoral head sphericity. RESULTS: In both sexes, the residual volume increased by age (P < 0.05). Despite significantly smaller femoral head size in older ages (> 13 years) in females, there were no sex-differences in residual volume and aspherity index. There were no age-related changes in mean diameter difference in both sexes (P = 0.07) with no significant sex-differences across different age groups (P = 0.06). In contrast, there were significant increases in local aspherity (maximum diameter difference) across whole surface of the femoral head and all quadrants except the inferior regions in males (P = 0.03). There were no sex-differences in maximum diameter difference at any regions and age group (P > 0.05). Increased alpha angle was only correlated to increased mean diameter difference across overall surface of the femoral head (P = 0.024). CONCLUSION: There is a substantial localized asphericity in asymptomatic hips which increases with age in. While 2D measured alpha angle can capture overall asphericity of the femoral head, it may not be sensitive enough to represent regional asphericity patterns.

5.
Micromachines (Basel) ; 15(7)2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39064420

RESUMO

To explore the size, morphology, and distribution patterns of internal pore defects in WE43 magnesium alloy formed by laser powder bed fusion (LPBF), as well as their impact on its mechanical properties, computer tomography (CT), metallographic microscopy, and scanning electron microscopy were used to observe the material's microstructure and the morphology of tensile test fractures. The study revealed that a large number of randomly distributed non-circular pore defects exist internally in the LPBF-formed WE43 magnesium alloy, with a defect volume fraction of 0.16%. Approximately 80% of the defects had equivalent diameters concentrated in the range of 10∼40 µm, and 56.2% of the defects had sphericity values between 0.65∼0.7 µm, with the maximum defect equivalent diameter being 122 µm. There were a few spherical pores around 20 µm in diameter in the specimens, and unfused powder particles were found in pore defects near the edges of the parts. Under the test conditions, the fusion pool structure of LPBF-formed WE43 magnesium alloy resembled a semi-elliptical shape with a height of around 66 µm, capable of fusion three layers of powder material in a single pass. Columnar grains formed at the edge of individual fusion pools, while the central area exhibited equiaxed grains. The "scale-like pattern" formed by overlapping fusion pool structures resulted in the microstructure of LPBF-formed WE43 magnesium alloy mainly consisting of fine equiaxed grains with a size of 2.5 µm and columnar grains distributed in a band-like manner.

6.
Artigo em Inglês | MEDLINE | ID: mdl-39085441

RESUMO

PURPOSE: Investigating the performance of the new Dophi™ M150E Microwave Ablation System, in terms of temperature distribution, ablation size and shape, reproducibility. MATERIALS AND METHODS: The Dophi™ M150E Microwave Ablation System was tested on ex vivo liver, lung and kidney, at 6 different settings of time, power and number of MW antennas (single antenna: 50 and 100 W at 5 and 10 min; double antenna: 75 W at 5 and 10 min). The temperature distribution was recorded by Fiber Bragg Grating sensors, placed at different distances from the antennas. The ablation axes were measured and the sphericity index was calculated. RESULTS: The standard deviation of ablation axes was < 5 mm, except at the highest energy and time setting for the lung. A maximum temperature rise of ~ 80 °C was measured. The measured ablation axes are overall comparable with the manufacture's values, especially at lower power and with one MW antenna (average maximum difference is 7 mm). The mean sphericity index of 0.95, 0.79 and 0.9 was obtained for the liver, lung and kidney, respectively, with a single antenna. With double antenna setup, the sphericity index was closer to 1 when 75 W for 10 min were used. CONCLUSIONS: Dophi™ M150E allows good reproducibility of ablation axes for all cases except in the lung at the highest energy level. With one antenna, an almost spherical ablation area for the liver and kidney was obtained. Using double antenna results in more homogeneous temperature distribution within the tissue compared to single antenna.

7.
Int J Biol Macromol ; 277(Pt 3): 134141, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39053823

RESUMO

Sodium alginate has good biocompatibility and is widely used in the study of drug carriers. In this paper, a method to prepare calcium alginate microspheres with high sphericity based on double emulsion droplets was proposed, in which sodium alginate is used as the innermost phase. By adjusting the density of the system, the double-emulsion droplets could be suspended in the collecting solution, leading to the homogeneous reaction between the sodium alginate droplets and the calcium ions. By changing the flow rate, the size of the droplets could be changed, and by changing the concentration of calcium ions in the collecting solution, the sphericity of the calcium alginate microspheres could be changed. Then the swelling properties and drug release properties of calcium alginate microspheres were determined. The drug delivery study revealed that the insulin-loaded Ca-Alginate microspheres were able to decrease blood glucose by 41.4 % after oral administration to mice. Thus, the Ca-Alginate microsphere is a suitable candidate for controlled pH-sensitive drug delivery.


Assuntos
Alginatos , Portadores de Fármacos , Emulsões , Insulina , Microesferas , Alginatos/química , Insulina/química , Insulina/administração & dosagem , Emulsões/química , Animais , Camundongos , Administração Oral , Portadores de Fármacos/química , Liberação Controlada de Fármacos , Difusão , Glicemia/efeitos dos fármacos , Concentração de Íons de Hidrogênio , Tamanho da Partícula , Géis/química , Sistemas de Liberação de Medicamentos
8.
ESC Heart Fail ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38840435

RESUMO

AIMS: This study aimed to compare the changes in the left ventricle (LV) and right ventricle (RV) geometry and performance after the implantation of HeartMate II (HMII) and HeartMate 3 (HM3). In addition, we investigated whether the echocardiographic parameters LV sphericity index (LVSI) and the novel pressure-dimension index (PDI) can predict post-operative right ventricular failure (RVF). METHODS AND RESULTS: Between 2012 and 2020, 46 patients [HMII (n = 22) and HM3 (n = 24)] met the study's criteria and had echocardiography tests pre-operatively, 6 and 12 months post-operatively. The LVSI and PDI were calculated together with the standard LV and RV echocardiographic parameters. The mean follow-up was 24 ± 7 months. In both groups, the LV end-diastolic diameter (LVEDD) significantly decreased 12 months post-operatively compared with the pre-operative values (HMII: 6.4 ± 1.4 cm vs. 5.7 ± 0.9 cm, P = 0.040; HM3: 6.7 ± 1.3 cm vs. 5.5 ± 0.9 cm, P < 0.01, respectively). RV function 12 months post-operatively was better in the HM3 group than in the HMII group, as indicated by a significantly higher RV fractional area change (RVFAC) in the HM3 group than in the HMII group 12 months post-operatively (35 ± 12% vs. 26 ± 16%, P = 0.039), significantly higher tricuspid annular plane systolic excursion (TAPSE) in the HM3 group 12 months post-operatively compared with the HMII group (13.9 ± 1.9 mm vs. 12.0 ± 2.1 mm, P = 0.002), and the tissue Doppler estimated tricuspid annular systolic velocity (TASV) was also significantly higher in the HM3 group 12 months post-operatively compared with the HMII group (11.5 ± 2.7 mm/s vs. 9.9 ± 1.5 mm/s, P = 0.020). The LVSI value was significantly higher 12 months post-operatively in the HMII group than in the HM3 group (1.2 ± 0.4 vs. 0.8 ± 0.2, P = 0.001, respectively), indicating worse geometric changes. The PDI decreased 12 months post-operatively in the HM3-group compared with the baseline (3.4 ± 1.4 mmHg/cm2 vs. 2.0 ± 0.8 mmHg/cm2, P < 0.001). In the univariate and multivariate analyses, only the pre-operative PDI was a predictor of post-operative RVF [odds ratio: 3.84 (95% CI: 1.53-18.16, P = 0.022)]. The area under the curve for pre-operative PDI was 0.912. The 2 year survival was significantly better in the HM3 group (log-rank, P = 0.042). CONCLUSIONS: The design of HM3 offered better geometrical preservation of the LV and enabled normal PDI values, leading to improved RV function, as indicated by better RVFAC, TAPSE, and TASV values. The use of pre-operative PDI as an additional tool for established risk scores might offer a better pre-operative predictor of RVF.

9.
J Ultrasound Med ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38923585

RESUMO

BACKGROUND: Although the fetal sphericity index (SI) and fractional shortening (FS) of 24 transverse segments have been previously reported after the 20th gestational week, there have been no reports during the first and early second trimester. OBJECTIVE: This study aimed to clarify the SI and FS of 24 transverse segments in normal fetuses before the 20th gestational week. METHODS: A total of 101 normal fetuses aged between 12 and 20 gestational weeks were examined. The displacement of the ventricular endocardium during the cardiac cycle was computed using speckle-tracking software (GE Healthcare, Milwaukee, WI). We analyzed the length of 24 end-diastolic lateral segments and the end-diastolic basal (seg1-6)- middle (Seg7-15)-apical (Seg16-24) distribution from the base to the apex of each ventricle, according to the method described by DeVore et al. The SI and FS were computed for each of the 24 segments by dividing the mid-basal-apical length by the transverse size. RESULTS: The SI for each segment was independent of the gestational age. The SI of the right ventricle was significantly lower than that of the left ventricle for segments 1-14, suggesting that the right ventricle was more spherical than the left ventricle in the basal segment only. The FS of the right ventricle was significantly lower than that of the left ventricle in segments 1 to 2 and 13 to 24. CONCLUSION: The morphology of the ventricles before 20 weeks of gestation differs from that between 20 and 40 weeks of gestation. This difference may be related to myocardial densification or performance.

10.
Eur Heart J Cardiovasc Imaging ; 25(8): 1155-1163, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-38487870

RESUMO

AIMS: Embolic stroke of undetermined source (ESUS) results in significant morbidity. A left atrial (LA) myopathy is implicated in a proportion of these patients. We hypothesized that LA shape varies by cause of stroke [CE (cardioembolic) vs. ESUS]. METHODS AND RESULTS: A total of 236 ischaemic stroke and atrial fibrillation (AF) patients and controls were recruited prospectively. AF was classified as paroxysmal AF (PAF) or persistent AF (PersAF). Stroke patients comprised CE stroke secondary to AF and ESUS. There were 81 AF (47 PAF, 34 PersAF), 50 ESUS, 57 CE patients [subdivided into CE with PAF (CEpaf) and CE with PersAF (CEpers)], and 48 controls. Echocardiographic parameters including LA volume, function, and shape/sphericity (3D LA sphericity and 2D-derived LA circularity, ellipticity, sphericity, and eccentricity indices) were evaluated. Increased LA volume and sphericity with LA dysfunction were present in CE, AF, and ESUS groups compared with controls. K-means cluster analysis demonstrated a spectrum of LA myopathy with controls at the lowest and CEpers and PersAF at the upper extremes, with ESUS, PAF, and CEpaf being similar and falling between these extremes. After adjusting for age, sex, and left ventricular (LV) and LA parameters, LA sphericity markers differentiated ESUS from controls (P < 0.01). CONCLUSION: Alterations in LA shape are present in ESUS, AF, and CE patients, particularly increased spherical remodelling. The novel markers of LA sphericity proposed may identify LA myopathy in ESUS patients and potentially guide management for secondary prevention.


Assuntos
Fibrilação Atrial , AVC Embólico , Átrios do Coração , Humanos , Feminino , Masculino , Idoso , AVC Embólico/diagnóstico por imagem , AVC Embólico/etiologia , Estudos Prospectivos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Pessoa de Meia-Idade , Estudos de Casos e Controles , Átrios do Coração/diagnóstico por imagem , Ecocardiografia/métodos , Medição de Risco , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/complicações
11.
Curr Cardiol Rev ; 20(2): 93-101, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38351687

RESUMO

Asymptomatic primary mitral regurgitation due to myxomatous degeneration of the mitral valve leaflets may remain so for long periods, even as left ventricular function progresses to a decompensated stage. During the early compensated stage, the ventricle's initial response to the volume overload is an asymmetric increase in the diastolic short axis dimension, accomplished by a diastolic shift of the interventricular septum into the right ventricular cavity, creating a more spherical left ventricular diastolic shape, increasing diastolic filling and stroke volume. Early valve repair is recommended to reduce postoperative left ventricular dysfunction. Early serial measurements of left ventricular sphericity index [LV-Si]. during the compensated stage of mitral regurgitation might identify subtle changes in left ventricular shape and assist in determining the optimal earliest timing for surgical intervention.


Assuntos
Ventrículos do Coração , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Ventrículos do Coração/fisiopatologia , Valva Mitral/cirurgia , Função Ventricular Esquerda/fisiologia , Doenças Assintomáticas , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/etiologia , Fatores de Tempo , Volume Sistólico/fisiologia , Procedimentos Cirúrgicos Cardíacos/métodos
12.
Pediatr Cardiol ; 45(4): 740-748, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38393337

RESUMO

Morphology and function in a fetal heart with severe tricuspid regurgitation remains challenging. The aim of this study was to assess cardiac morphology and function in fetuses with severe tricuspid regurgitation by fetal heart quantification (HQ) and to assess the practical value of fetal HQ. Clinical information was analyzed for 63 pregnant women who underwent fetal cardiac ultrasonography. The women were divided into those who had a fetus with severe tricuspid regurgitation (n = 20) and those with a normal fetus (n = 40). The global sphericity index (GSI), fractional area change (FAC), and global longitudinal strain (GLS) of both ventricles and the sphericity index (SI) and fractional shortening (FS) of 24 segments were quantified by fetal HQ using speckle tracking imaging. Fetuses with severe tricuspid regurgitation had a significantly lower GSI (1.14 ± 0.10 vs. 1.26 ± 0.08, p < 0.001) and a higher GSI Z-score (-0.98 ± 1.01 vs. 0.25 ± 0.87, p < 0.001) as well as a significantly lower right ventricular FAC (36.50 ± 7.34% vs. 45.19 ± 3.39%, p < 0.001), FAC Z-score (-1.02 ± 1.41 vs. 0.49 ± 0.74, p < 0.001), and GLS (-21.01 ± 5.66% vs. 45.19 ± 3.49%, p < 0.001). The SI and SI Z-score were significantly lower in segments 1-18 of the right ventricle in fetuses with severe tricuspid regurgitation (p < 0.05); furthermore, FS of segments 1-12 and 19-24 and the FS Z-score of segments 18-24 were significantly lower in fetuses with severe tricuspid regurgitation (p < 0.05). Fetal HQ is useful for evaluation of cardiac morphology and function in fetuses with severe tricuspid regurgitation and can provide important reference information for both clinical diagnosis and treatment.


Assuntos
Insuficiência da Valva Tricúspide , Humanos , Feminino , Gravidez , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Coração Fetal/diagnóstico por imagem , Ventrículos do Coração , Ultrassonografia Pré-Natal/métodos
13.
Eur Stroke J ; 9(2): 383-390, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38179883

RESUMO

INTRODUCTION: Perihematomal edema (PHE) represents secondary brain injury and a potential treatment target in intracerebral hemorrhage (ICH). However, studies differ on optimal PHE volume metrics as prognostic factor(s) after spontaneous, non-traumatic ICH. This study examines associations of baseline and 24-h PHE shape features with 3-month outcomes. PATIENTS AND METHODS: We included 796 patients from a multicentric trial dataset and manually segmented ICH and PHE on baseline and follow-up CTs, extracting 14 shape features. We explored the association of baseline, follow-up, difference (baseline/follow-up) and temporal rate (difference/time gap) of PHE shape changes with 3-month modified Rankin Score (mRS) - using Spearman correlation. Then, using multivariable analysis, we determined if PHE shape features independently predict outcome adjusting for patients' age, sex, NIH stroke scale (NIHSS), Glasgow Coma Scale (GCS), and hematoma volume. RESULTS: Baseline PHE maximum diameters across various planes, main axes, volume, surface, and sphericity correlated with 3-month mRS adjusting for multiple comparisons. The 24-h difference and temporal change rates of these features had significant association with outcome - but not the 24-h absolute values. In multivariable regression, baseline PHE shape sphericity (OR = 2.04, CI = 1.71-2.43) and volume (OR = 0.99, CI = 0. 98-1.0), alongside admission NIHSS (OR = 0.86, CI = 0.83-0.88), hematoma volume (OR = 0.99, CI = 0. 99-1.0), and age (OR = 0.96, CI = 0.95-0.97) were independent predictors of favorable outcomes. CONCLUSION: In acute ICH patients, PHE shape sphericity at baseline emerged as an independent prognostic factor, with a less spherical (more irregular) shape associated with worse outcome. The PHE shape features absolute values over the first 24 h provide no added prognostic value to baseline metrics.


Assuntos
Edema Encefálico , Hemorragia Cerebral , Humanos , Masculino , Feminino , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/terapia , Hemorragia Cerebral/patologia , Idoso , Pessoa de Meia-Idade , Edema Encefálico/diagnóstico por imagem , Edema Encefálico/etiologia , Hematoma/diagnóstico por imagem , Hematoma/patologia , Prognóstico , Escala de Coma de Glasgow , Tomografia Computadorizada por Raios X
14.
J Family Med Prim Care ; 12(10): 2428-2433, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38074270

RESUMO

Introduction: This pandemic has been accompanied by an overabundance of information and misinformation, an 'infodemic' on a global scale which have made acceptability of COVID-19 vaccine a major challenge. The objective of the study was to find out the Beliefs of mothers towards COVID-19 vaccine for children and its impact on vaccine hesitancy. Materials and Methods: After obtaining Institutional ethical clearance and informed consent, a total of 360 mothers who were having at least one child from 5 to 18 years were recruited based on simple random sampling. Face-to-face interview was conducted. The questionnaire was based on the WHO-SAGE working group on vaccine hesitancy. Based on Bartlett's test of sphericity, the model was found to be fit (there is adequate number of correlations for factor analysis) and KMO test results imply the samples are adequate for factor analysis. K means cluster analysis was used to divide the samples into three clusters and individual respondent's cluster membership was also identified. Results: It was found 49.4% of mothers were hesitant to vaccine their children against COVID-19. The seven items (reasons for vaccine hesitancy) were grouped into three dimensions (believes in vaccine effectiveness but concerned about side effects, believes in the importance of taking COVID vaccine, trusts information about COVID vaccine), based on how each item loads on to each of three factors. Cluster 1 was that they believe in effectiveness of vaccine but are concerned about side effects (.92094). Conclusion: Mothers' concerns were mainly about the safety and adverse effects of vaccine.

15.
Cancer Imaging ; 23(1): 124, 2023 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-38105231

RESUMO

BACKGROUND: The presence of mediastinal lymph node metastasis is important because it is related to the treatment and prognosis of lung cancer. Although prevalently used, evaluation of lymph nodes is not always reliable. We introduced sphericity as a criterion for evaluating morphologic differences between metastatic and nonmetastatic nodes. METHODS: We reviewed the cases of 66 patients with N2 disease and of 68 patients with N0-1 disease who underwent lobectomy with mediastinal dissection between January 2012 and December 2021. The sphericity of the dissected station lymph nodes, which represents how close the node is to being a true sphere, was evaluated along with the diameter and volume. Each parameter was obtained and evaluated for ability to predict metastasis. RESULTS: Metastatic lymph nodes had a larger short-axis diameter (average: 8.2 mm vs. 5.4 mm, p < 0.001) and sphericity (average: 0.72 vs. 0.60, p < 0.001) than those of nonmetastatic lymph nodes. Short-axis diameter ≥ 6 mm and sphericity ≥ 0.60 identified metastasis with 76.2% sensitivity and 70.2% specificity (AUC = 0.78, p < 0.001) and 92.1% sensitivity and 53.9% specificity (AUC = 0.78, p < 0.001), respectively. For lymph nodes with a short-axis diameter ≥ 5 mm, sphericity ≥ 0.60 identified metastasis with 84.1% sensitivity and 89.3% specificity. CONCLUSION: By using 3D-CT analysis to examine sphericity, we showed that metastatic lymph nodes became spherical. Our method for predicting lymph node metastasis based on sphericity of lymph nodes with a short-axis diameter ≥ 5 mm could do so with higher sensitivity than the conventional method, and with acceptable specificity.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/patologia , Carcinoma Pulmonar de Células não Pequenas/patologia , Metástase Linfática/patologia , Tomografia Computadorizada por Raios X , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Estadiamento de Neoplasias
16.
J Matern Fetal Neonatal Med ; 36(2): 2285239, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38010356

RESUMO

Objective: To evaluate the changes in cardiac morphology of fetuses with congenital heart disease (CHD) using the fetal heart quantitative technique (fetalHQ).Methods: A total of 20 normal pregnant women (control group) and 20 pregnant women suspected of fetal CHD (case group) were included in this study. The dynamic images of the four-chamber view of the fetal heart were recorded and analyzed using fetalHQ. The global sphericity index (GSI) and 24-segment SI of the two groups were compared. The differences in the left and right ventricular 24-segment SI for each group were investigated.Results: There was no statistically significant difference in the GSI between the two groups (p > 0.05). The difference in the SI values of left ventricular segments 1-2 between the case group and control group was statistically significant (all p < 0.05), while the intergroup difference in SI of left ventricular segments 3-24 was not significant (all p > 0.05). The SI of the 24 segments of the right ventricle showed no significant intergroup difference (all p > 0.05). The difference in the left and right ventricular 24-segment SI in the case group did not reach statistical significance (all p > 0.05). In the control group, the SI values between the left and right ventricles were significantly different in segments 18-24 (all p < 0.05), and no significant difference was found in segments 1-17 (all p > 0.05). There was a statistically significant intergroup difference in the percentage of unusual left ventricular SI, determined based on Z-score (p < 0.05), and the percentage of outliers for the right ventricle between the two groups showed no significant difference (p > 0.05).Conclusion: The fetalHQ is regarded as a straightforward and reliable approach for assessing the cardiac GSI and 24-segment SI of left and right ventricles in fetuses diagnosed with CHD. While CHD may not significantly impact the overall shape of the fetal heart or the geometric shape of the right ventricle, in this study, a notable increase in SI values for the left ventricular 1-2 segments was observed, indicating a more flattened ventricular chamber. Additionally, the morphological distinctions between the left and right ventricles in fetuses with CHD are no longer discernible.


Assuntos
Doenças Fetais , Cardiopatias Congênitas , Feminino , Humanos , Gravidez , Ultrassonografia Pré-Natal/métodos , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/anormalidades
17.
J Pers Med ; 13(11)2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-38003916

RESUMO

The prognostic impact of tumor volume and tumor sphericity was analyzed in 95 patients affected by oral cancer. The pre-operative computed tomography (CT) scans were used to segment the tumor mass with threshold tools, obtaining the corresponding volume and sphericity. Events of recurrence and tumor-related death were detected for each patient. The mean follow-up time was 31 months. A p-value of 0.05 was adopted. Mean tumor volume resulted higher in patients with recurrence or tumor-related death at the Student's t-test (respectively, 19.8 cm3 vs. 11.1 cm3, p = 0.03; 23.3 cm3 vs. 11.7 cm3, p = 0.02). Mean tumor sphericity was higher in disease-free patients (0.65 vs. 0.59, p = 0.04). Recurrence-free survival and disease-specific survival were greater for patients with a tumor volume inferior to the cut-off values of 21.1 cm3 (72 vs. 21 months, p < 0.01) and 22.4 cm3 (85 vs. 32 months, p < 0.01). Recurrence-free survival and disease-specific survival were higher for patients with a tumor sphericity superior to the cut-off value of 0.57 (respectively, 49 vs. 33 months, p < 0.01; 56 vs. 51 months, p = 0.01). To conclude, tumor volume and sphericity, three-dimensional parameters, could add useful information for better stratification of prognosis in oral cancer.

18.
Pharmaceutics ; 15(8)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37631240

RESUMO

Achieving homogeneity and reproducibility in the size, shape, and morphology of active pharmaceutical ingredient (API) particles is crucial for their successful manufacturing and performance. Herein, we describe a new method for API particle engineering using melt-jet printing technology as an alternative to the current solvent-based particle engineering methods. Paracetamol, a widely used API, was melted and jetted as droplets onto various surfaces to solidify and form microparticles. The influence of different surfaces (glass, aluminum, polytetrafluoroethylene, and polyethylene) on particle shape was investigated, revealing a correlation between substrate properties (heat conduction, surface energy, and roughness) and particle sphericity. Higher thermal conductivity, surface roughness, and decreased surface energy contributed to larger contact angles and increased sphericity, reaching a near-perfect micro-spherical shape on an aluminum substrate. The integrity and polymorphic form of the printed particles were confirmed through differential scanning calorimetry and X-ray diffraction. Additionally, high-performance liquid chromatography analysis revealed minimal degradation products. The applicability of the printing process to other APIs was demonstrated by printing carbamazepine and indomethacin on aluminum surfaces, resulting in spherical microparticles. This study emphasizes the potential of melt-jet printing as a promising approach for the precise engineering of pharmaceutical particles, enabling effective control over their physiochemical properties.

19.
Int J Cardiovasc Imaging ; 39(9): 1753-1763, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37515682

RESUMO

PURPOSE: Left atrial (LA) sphericity is a novel, geometry-based parameter that has been used to visualize and quantify LA geometrical remodeling in patients with atrial fibrillation (AF). This study examined the association between LA sphericity, and LA longitudinal strain and strain rate measured by feature-tracking in AF patients. METHODS: 128 AF patients who underwent cardiovascular magnetic resonance (CMR) imaging in sinus rhythm prior to their pulmonary vein isolation (PVI) procedure were retrospectively analyzed. LA sphericity was calculated by segmenting the LA (excluding the pulmonary veins and the LA appendage) on a 3D contrast enhanced MR angiogram and comparing the resulting shape with a perfect sphere. LA global reservoir strain, conduit strain, contractile strain and corresponding strain rates were derived from cine images using feature-tracking. For statistical analysis, Pearson correlations, multivariable logistic regression analysis, and Student t-tests were used. RESULTS: Patients with a spherical LA (dichotomized by the median value) had a lower reservoir strain and conduit strain compared to patients with a non-spherical LA (-15.4 ± 4.2% vs. -17.1 ± 3.5%, P = 0.02 and - 8.2 ± 3.0% vs. -9.5 ± 2.6%, P = 0.01, respectively). LA strain rate during early ventricular diastole was also different between both groups (-0.7 ± 0.3s- 1 vs. -0.9 ± 0.3s- 1, P = 0.001). In contrast, no difference was found for LA contractile strain (-7.2 ± 2.6% vs. -7.6 ± 2.2%, P = 0.30). CONCLUSIONS: LA passive strain is significantly impaired in AF patients with a spherical LA, though this relation was not independent from LA volume.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Valor Preditivo dos Testes , Átrios do Coração , Ablação por Cateter/métodos
20.
J Xray Sci Technol ; 31(5): 865-877, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37424488

RESUMO

BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors' limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Calibragem , Reprodutibilidade dos Testes , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Algoritmos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA