1.
Sensors (Basel) ; 19(9)2019 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-31035501

RESUMO

This paper presents a novel tangential electric-field sensor with an embedded integrated balun for sensing up a tangential electric field over a circuit surface in the near-field measurements covering the GPS band. The integrated balun is embedded into the sensor to transform the differential voltage induced by the electric dipole into the single output voltage. The measurement system with a high mechanical resolution for the characterizations and tests of the sensor is detailed in this paper. The frequency response of the sensor characterized by a microstrip line from 1.35 GHz to 1.85 GHz (covering the GPS band) is rather flat. The rejection to the magnetic field of the sensor is up to 20.1 dB. The applications and validations of the sensor are conducted through passive/active circuit measurements.

2.
Front Physiol ; 9: 1439, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30459628

RESUMO

Purpose: The purpose of this study was to investigate the need for high-resolution detailed anatomical modeling to correctly estimate radio-frequency (RF) safety during magnetic resonance imaging (MRI). RF-induced heating near metallic implanted devices depends on the electric field tangential to the device (Etan ). Etan and specific absorption rate (SAR) were analyzed in blood vessels of an anatomical model to understand if a standard gel phantom accurately represents the potential heating in tissues due to passive vascular implants such as stents. Methods: A numerical model of an RF birdcage body coil and an anatomically realistic virtual patient with a native spatial resolution of 1 mm3 were used to simulate the in vivo electric field at 64 MHz (1.5 T MRI system). Maximum values of SAR inside the blood vessels were calculated and compared with peaks in a numerical model of the ASTM gel phantom to see if the results from the simplified and homogeneous gel phantom were comparable to the results from the anatomical model. Etan values were also calculated in selected stent trajectories inside blood vessels and compared with the ASTM result. Results: Peak SAR values in blood vessels were up to ten times higher than those found in the ASTM standard gel phantom. Peaks were found in clinically significant anatomical locations, where stents are implanted as per intended use. Furthermore, Etan results showed that volume-averaged SAR values might not be sufficient to assess RF safety. Conclusion: Computational modeling with a high-resolution anatomical model indicated higher values of the incident electric field compared to the standard testing approach. Further investigation will help develop a robust safety testing method which reflects clinically realistic conditions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA