RESUMO
Abstract Background: The cochlear implant (CI) is effective for rehabilitating patients with severe to profound sensorineural hearing loss. However, its placement and use have been associated with various complications, such as those affecting the vestibular system. The objective of this study was to compare vestibular function using the video head impulse test (vHIT) in pediatric patients before and after CI placement. Methods: A descriptive and retrospective study was conducted. The outcomes of 11 pediatric patients of both sexes with a history of profound hearing loss were evaluated. The results of vestibular-ocular reflex (VOR) gain, saccades, asymmetry, Pérez Rey (PR) index, and VOR/saccade ratio for both ears obtained by the vHIT test before and after CI placement were compared. Results: Of the 11 patients evaluated, the VOR gain showed that 81.8% had normal function, 18.2% had hypofunction, and no patients had hyperfunction before implantation. No statistically significant differences were found when compared with post-implant off and post-implant on conditions (p > 0.05). The extracted variables, asymmetry, PR index, and the VOR/saccades ratio also showed no statistically significant differences between the pre- and post-implant conditions, whether off or on. Conclusions: The vestibular function of pediatric patients did not show significant changes before and after CI placement. The vHIT test is a valuable tool for assessing vestibular function and could be considered a criterion for surgical and rehabilitation decisions in patients undergoing CI placement.
Resumen Introducción: El implante coclear es un dispositivo eficaz para la rehabilitación de pacientes con hipoacusia neurosensorial severa a profunda. Sin embargo, su colocación y uso se ha asociado a diversas complicaciones, entre ellas a nivel del sistema vestibular. El objetivo del presente estudio fue comparar la función vestibular mediante la prueba de videoimpulso cefálico (vHIT) de pacientes pediátricos antes y después de la colocación del implante coclear. Métodos: Se llevó a cabo un estudio descriptivo y retrospectivo. Se evaluaron los resultados de 11 pacientes pediátricos de ambos sexos con antecedente de hipoacusia profunda. Se compararon los resultados de ganancia del VOR, sacadas, asimetría, índice PR así como la relación VOR/sacadas para ambos oídos obtenidos mediante la prueba vHIT antes y después de la colocación del implante coclear. Resultados: De los 11 pacientes evaluados, la ganancia del VOR mostró que el 81.8% tenía normofunción, 18.2% hipofunción y ningún paciente hiperfunción antes del implante. Al compararlo con la ganancia post implante apagado y post implante encendido no se encontraron diferencias estadísticamente significativas (p > 0.05). Las variables sacadas, asimetría, índice PR así como la relación VOR/sacadas tampoco mostraron diferencias estadísticamente significativas entre las condiciones pre y pos implante ya sea apagado o encendido. Conclusiones: La función vestibular de pacientes pediátricos no mostró cambios significativos previo y posterior a la colocación del implante coclear. La prueba vHIT es una herramienta útil que permite evaluar la función vestibular y que podría considerarse como criterio para tomar decisiones quirúrgicas en pacientes que se encuentran en protocolo para implante coclear.
RESUMO
BACKGROUND: The cochlear implant (CI) is effective for rehabilitating patients with severe to profound sensorineural hearing loss. However, its placement and use have been associated with various complications, such as those affecting the vestibular system. The objective of this study was to compare vestibular function using the video head impulse test (vHIT) in pediatric patients before and after CI placement. METHODS: A descriptive and retrospective study was conducted. The outcomes of 11 pediatric patients of both sexes with a history of profound hearing loss were evaluated. The results of vestibular-ocular reflex (VOR) gain, saccades, asymmetry, Pérez Rey (PR) index, and VOR/saccade ratio for both ears obtained by the vHIT test before and after CI placement were compared. RESULTS: Of the 11 patients evaluated, the VOR gain showed that 81.8% had normal function, 18.2% had hypofunction, and no patients had hyperfunction before implantation. No statistically significant differences were found when compared with post-implant off and post-implant on conditions (p > 0.05). The extracted variables, asymmetry, PR index, and the VOR/saccades ratio also showed no statistically significant differences between the pre- and post-implant conditions, whether off or on. CONCLUSIONS: The vestibular function of pediatric patients did not show significant changes before and after CI placement. The vHIT test is a valuable tool for assessing vestibular function and could be considered a criterion for surgical and rehabilitation decisions in patients undergoing CI placement.
INTRODUCCIÓN: El implante coclear es un dispositivo eficaz para la rehabilitación de pacientes con hipoacusia neurosensorial severa a profunda. Sin embargo, su colocación y uso se ha asociado a diversas complicaciones, entre ellas a nivel del sistema vestibular. El objetivo del presente estudio fue comparar la función vestibular mediante la prueba de videoimpulso cefálico (vHIT) de pacientes pediátricos antes y después de la colocación del implante coclear. MÉTODOS: Se llevó a cabo un estudio descriptivo y retrospectivo. Se evaluaron los resultados de 11 pacientes pediátricos de ambos sexos con antecedente de hipoacusia profunda. Se compararon los resultados de ganancia del VOR, sacadas, asimetría, índice PR así como la relación VOR/sacadas para ambos oídos obtenidos mediante la prueba vHIT antes y después de la colocación del implante coclear. RESULTADOS: De los 11 pacientes evaluados, la ganancia del VOR mostró que el 81.8% tenía normofunción, 18.2% hipofunción y ningún paciente hiperfunción antes del implante. Al compararlo con la ganancia post implante apagado y post implante encendido no se encontraron diferencias estadísticamente significativas (p > 0.05). Las variables sacadas, asimetría, índice PR así como la relación VOR/sacadas tampoco mostraron diferencias estadísticamente significativas entre las condiciones pre y pos implante ya sea apagado o encendido. CONCLUSIONES: La función vestibular de pacientes pediátricos no mostró cambios significativos previo y posterior a la colocación del implante coclear. La prueba vHIT es una herramienta útil que permite evaluar la función vestibular y que podría considerarse como criterio para tomar decisiones quirúrgicas en pacientes que se encuentran en protocolo para implante coclear.
Assuntos
Implante Coclear , Implantes Cocleares , Teste do Impulso da Cabeça , Perda Auditiva Neurossensorial , Reflexo Vestíbulo-Ocular , Humanos , Feminino , Masculino , Teste do Impulso da Cabeça/métodos , Estudos Retrospectivos , Criança , Pré-Escolar , Reflexo Vestíbulo-Ocular/fisiologia , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/fisiopatologia , Perda Auditiva Neurossensorial/reabilitação , Gravação em Vídeo , Movimentos Sacádicos/fisiologia , Adolescente , Vestíbulo do Labirinto/fisiopatologiaRESUMO
BACKGROUND: We propose a Suppression Head IMPulse (SHIMP) test method that provides for equipment only through the use of InfraRed Video-OculoScopy (IR-VOS) and allows horizontal and vertical semicircular canal function evaluation in bedside mode. We therefore named the test InfraRed clinical SHIMP (IR-cSHIMP). METHODS: To check IR-cSHIMP diagnostic efficiency, we studied 22 normal subjects, 18 patients with unilateral, and 6 with bilateral deficient vestibulopathy. Each subject first underwent a vestibular examination and, only later, an IRc-SHIMP test. RESULTS: When the IR-cSHIMP test was performed in the horizontal plane, all normal subjects showed anti-compensatory saccades. When the vertical semicircular canal function was evaluated, the same result was obtained in all normal subjects except three, which were considered false positives. In patients with vestibular deficits, the test performed in the horizontal and vertical planes were always pathological, with 100% agreement between clinical and instrumental tests. CONCLUSIONS: Our bedside method proved to be fast, simple, and effective in discriminating between healthy and pathological subjects. It required only the same skill as the better-known cHIT. For these reasons, we believe that the IR-cSHIMP should be part of daily clinical practice as a useful tool in the selection of patients to undergo more sophisticated investigations.
RESUMO
BACKGROUND: Inner ear hemorrhage (IEH) is an increasingly recognized cochlear lesion that can cause sensorineural hearing loss (SNHL). Magnetic resonance imaging (MRI) is known to be the best imaging modality for clarifying the causes of SNHL and providing images that point to those causes. AIMS: Evaluate the lesional patterns in patients with presumed Inner ear hemorrhage (IEH) from radiological and functional aspects. MATERIAL AND METHODS: We retrospectively reviewed 10 patients performed in our institution from 2014 to 2020, with suspected labyrinthine hemorrhage based on radiological and functional examination. RESULTS: We included 8 patients with IEH and sensorineural hearing loss (SNHL). The median age was 55 years (range: 3 months - 78 years). The results from the MRI and functional tests were compared for each end-organ. Only three cases (37.5%) showed a correlation between signal abnormalities and dysfunction in the labyrinthine apparatus. CONCLUSIONS: In patients with SNHL inner ear hemorrhage needs to be ruled out in the differential diagnosis, so specific MRI sequences should be requested. It represents a way to a better understanding of the disorder and the variety of findings claim for a complete auditory and vestibular testing.
Assuntos
Otopatias , Orelha Interna , Perda Auditiva Neurossensorial , Perda Auditiva Súbita , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Perda Auditiva Súbita/diagnóstico , Orelha Interna/diagnóstico por imagem , Otopatias/complicações , Perda Auditiva Neurossensorial/diagnóstico por imagem , Perda Auditiva Neurossensorial/etiologia , Imageamento por Ressonância Magnética/métodos , Hemorragia/diagnóstico por imagem , Hemorragia/complicaçõesRESUMO
BACKGROUND: Vestibular function (VF) in patients with cochlear implantation (CI) performed during childhood is underinvestigated. OBJECTIVE: To study VF in patients receiving CI during childhood. MATERIAL & METHODS: Sixty patients (22 females) from 7-34 years old, unilaterally (n = 21) and bilaterally (n = 39) implanted, were included. Deafness was congenital (n = 45), consequential to meningitis (n = 3), skull fracture (n = 1), perinatal CMV infection (n = 1), ototoxic drugs (n = 1), unknown etiology (n = 9). VF was measured between 1 to 22 years after implantation, including calorics, v-HIT, c-VEMPS. Dizziness handicap inventory (DHI), age at independent walking(IW), sport activities were also investigated. RESULTS: Nine CI-patients (15%) reported dizziness/vertigo either prior or months to years after surgery. Comparison between symptomatic (15%), asymptomatic (85%), uni-bilaterally CI-patients showed no significant difference on VF's impairment for calorics (p = .603) and v-HIT (p = 1). Symptoms were not related to vestibular impairment. Age at implantation (p = 0.956), uni- bilateral (p = .32), simultaneous versus sequential (p = .134) did not influence IW age. DHI showed a tendency for being symptomatic at higher implantation age. Interval between CI, IWage, current age between surgery and vestibular evaluation did not have a significant effect on symptomatology. CONCLUSION & SIGNIFICANCE: This first middle to long-term evaluation of the VF in CI-patients, implanted in childhood, pointed out that 85% of patients were asymptomatic, with a mean time of >10 years after surgery. Vestibular impairment and symptoms seem to be mainly due to the underlying inner ear's disease rather than surgery.
Assuntos
Implante Coclear , Implantes Cocleares , Feminino , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Implante Coclear/efeitos adversos , Implantes Cocleares/efeitos adversos , Tontura/diagnóstico , Estudos Prospectivos , Vertigem/etiologiaRESUMO
AIM: To evaluate hearing and labyrinth functions following different osteotomy types (micro-compass saw, osteotome, and no osteotomy) performed in septorhinoplasty operations. MATERIAL AND METHOD: The study included 74 patients operated between January 2020 and March 2022, separated into 3 groups: Group 1: 24 patients (16 females and 8 males): osteotome was used for the osteotomy; Group 2: 24 patients (12 females and 12 males): micro-saw was used for osteotomy; and Group 3: 26 patients (17 females and 9 males): open technique septoplasty with no osteotomy. At 1 day before and 1 week after the operation, all the patients underwent audiological examination, tympanometry, vestibular evoked myogenic potentials (c-VEMP), video head impulse test (v-HIT), videonystagmography (VNG), and distortion product otoacoustic emission (DPOAE) tests. RESULTS: In the c-VEMP tests, significant differences were determined between the groups in respect of N1, P1, and N1-P1 latencies and N1-P1 amplitudes before and after the operation. In the v-HIT test, the change in right-side posterior gain postoperatively was statistically significant in the micro-saw group (p<0.05). The postoperative right lateral canal values were determined to be statistically significantly increased in the micro-saw group compared to the osteotome group (p<0.05). CONCLUSION: This is the only study in the literature to have determined vestibular effects with the evaluation of such a wide range of techniques. Previous studies in the literature have found no effect of osteotomy technique on the balance and hearing systems. The results of this study demonstrated that the preoperative and postoperative difference between the osteotomy techniques had an effect on the balance system. The change in the balance tests following an operation with classic osteotomy shows a greater predisposition to benign positional vertigo. In this sense, the micro-saw can be considered safer. Level of Evidence II This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Assuntos
Rinoplastia , Potenciais Evocados Miogênicos Vestibulares , Masculino , Feminino , Humanos , Rinoplastia/efeitos adversos , Rinoplastia/métodos , Nariz , Osteotomia/efeitos adversos , Osteotomia/métodos , Exame FísicoRESUMO
Objective: Evaluation at long term of the impact of the stereotactic surgery (SRS) on the vestibular function in vestibular schwannoma (VS) patients. Study design and setting: Retrospective study in a tertiary referral center. Patients: Fifty-one VS patients were included (34 females;17 males), aged from 41 to 78 years treated exclusively with SRS. Intervention: Vestibular function was assessed before SRS and with median time interval of 14 (FU1) and 25 (FU2) months after treatment. Vestibular evaluation included: history, clinical vestibular examination, videonystagmography, head impulse test (v-HIT) and cervical vestibular evoked myogenic potentials (c-VEMPS). Results: Before SRS, caloric testing (Caloric) was impaired in 77%; after treatment, in 92% (FU1) and 77% (FU2). Lateral HIT was decreased in 22% before SRS, in 39% at FU1 and FU2. C-VEMPS were absent in 50% before SRS, in 76% at FU1 and, FU2. Before SRS, no statistically significant association was found between asymptomatic and symptomatic patients with respect to the results of Caloric, v-HIT and c-VEMPS. This lack of association was also seen after SRS, at FU1 and FU2. Conclusion: Our study showed that the impairment of the vestibular function might be attributed to the VS itself as well as to the radiation of the inner ear during SRS. The lateral SSC at low frequencies and the saccular function seem to be more involved with the time.
RESUMO
BACKGROUND: We assessed whether detection of stroke underlying acute vertigo using HINTS plus (head-impulse test, nystagmus type, test of skew, hearing loss) can be improved by video-oculography for automated head-impulse test (V-HIT) analysis. METHODS: We evaluated patients with acute vestibular syndrome (AVS) presenting to the emergency room using HINTS plus and V-HIT-assisted HINTS plus in a randomized sequence followed by cranial MRI and caloric testing. Image-confirmed posterior circulation stroke or vertebrobasilar TIA were the reference standards to calculate diagnostic accuracy. We repeated statistical analysis for a third protocol that was composed post hoc by replacing the head-impulse test with caloric testing in the HINTS plus protocol. RESULTS: We included 30 AVS patients (ages 55.4 ± 17.2 years, 14 females). Of these, 11 (36.7%) had posterior circulation stroke (n = 4) or TIA (n = 7). Acute V-HIT-assisted HINTS plus was feasible and displayed tendentially higher accuracy than conventional HINTS plus (sensitivity: 81.8%, 95% CI 48.2-97.7%; specificity 31.6%, 95% CI 12.6-56.6% vs. sensitivity 72.7%, 95% CI 39.0-94.0%; specificity 36.8%, 95% CI 16.3-61.6%). The new caloric-supported algorithm showed high accuracy (sensitivity 100%, 95% CI 66.4-100%; specificity 66.7%, 95% CI 41-86.7%). CONCLUSIONS: Our study provides pilot data on V-HIT-assisted HINTS plus for acute AVS assessment and indicates the diagnostic value of integrated acute caloric testing.
RESUMO
Objectives: Video head impulse test (v-HIT) is a quick, non-invasive and relatively cheap test to evaluate vestibular function compared to the caloric test. The latter is, however, needed to decide on the optimal side to perform cochlear implantation to avoid the risk on inducing a bilateral vestibular areflexia. This study evaluates the effectiveness of using the v-HIT to select cochlear implant (CI) candidates who require subsequent caloric testing before implantation, in that way reducing costs and patient burden at the same time. Study Design: Retrospective study using clinical data from 83 adult CI-candidates, between 2015 and 2020 at the Leiden University Medical Center. Materials and Methods: We used the v-HIT mean gain, MinGain_LR, the gain asymmetry (GA) and a newly defined parameter, MGS (Minimal Gain & Saccades) as different models to detect the group of patients that would need the caloric test to decide on the ear of implantation. The continuous model MGS was defined as the MinGain_LR, except for the cases with normal gain (both sides ≥0.8) where no corrective saccades were present. In the latter case MGS was defined to be 1.0 (the ideal gain value). Results: The receiver operating characteristics curve showed a very good diagnostic accuracy with and area under the curve (AUC) of 0.81 for the model MGS. The v-HIT mean gain, the minimal gain and GA had a lower diagnostic capacity with an AUC of 0.70, 0.72, and 0.73, respectively. Using MGS, caloric testing could be avoided in 38 cases (a reduction of 46%), with a test sensitivity of 0.9 (i.e., missing 3 of 28 cases). Conclusions: The newly developed model MGS balances the sensitivity and specificity of the v-HIT better than the more commonly evaluated parameters such as mean gain, MinGain_LR and GA. Therefore, taking the presence of corrective saccades into account in the evaluation of the v-HIT gain can considerably reduce the proportion of CI-candidates requiring additional caloric testing.
RESUMO
AIM: Meniere's Disease (MD) is a chronic disease that is characterized by intermittent episodes of tinnitus, vertigo, and progressivefluctuating sensorineural hearing loss together with aural fullness. The aim of this study is to evaluate Meniere's disease patients with vestibular test battery as Videonystagmography (VNG), Vestibular Evoked Myogenic Potentials (VEMPs) and Video Head Impulse Test (V-HIT) to assess peripheral and central vestibular systems. METHODS: 16 bilateral, 17 unilateral patients suffering from MD (mean age, 40.90 years, range, 23 to 66 years; 20 women and 13 men) comprised the study group, and 39 healthy (mean age, 38.10 years, range from 21 to 60 years; 22 women and 17 men) volunteers formed control group. Evaluation of peripheral and central vestibular systems changes with oculomotor tests, caloric test, C-VEMPs, O-VEMPs, and the evaluation of the vestibular ocular reflex (VOR) using the V-HIT. RESULT: Twenty-six ears out of the forty-nine ears that were affected by Meniere's disease were diagnosed as otolith or ampullary dysfunction. As to O-VEMPs testing, N1 and P1 waves could not be obtained from thirty of the forty-nine ears affected by Meniere's disease. As for obtained N1 and P1 waves, prolonged N1 and P1 wave latencies, and reduced amplitude was observed in Meniere's group. P1 and N1 waves were not observed in 5 bilateral and 2 unilateral Meniere's patients (12 ears out of 49 affected ears) in C-VEMPs recordings (23.9%). In Meniere's patients' group, 44.9% of the velocity gain values were obtained in the pathologic borders of v- HIT. In addition to lower velocity gain, higher ratios of asymmetry were obtained from the ears affected with Meniere's disease. CONCLUSION: According to these results, it can be concluded that Meniere's disease significantly affects the peripheral vestibular system but the functions of the central vestibular system were not affected.
Assuntos
Doença de Meniere/diagnóstico , Doença de Meniere/fisiopatologia , Potenciais Evocados Miogênicos Vestibulares , Testes de Função Vestibular , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto JovemRESUMO
Objective Usher's syndrome type II (USH2) is characterized by moderate to profound congenital hearing loss, later onset of retinitis pigmentosa, and normal vestibular function. Recently, a study investigating the vestibular function of USH2 patients demonstrated a pathologic response to vestibular tests. In this cross-sectional study we performed vestibular tests of a group patients with genetic diagnosis of USH2 syndrome to demonstrate if vestibular damage is present in USH2 patients. Study Design Cross-sectional study. Setting Tertiary referral center. Subjects and Methods Mutated genes of 7 patients with a clinical diagnosis of USH2 were evaluated. Vestibular function was investigated by audiometry, Fitzgerald-Hallpike caloric vestibular testing, cervical vestibular evoked myogenic potentials (C-VEMPs), ocular vestibular evoked myogenic potentials (O-VEMPs), and video head impulse test (v-HIT). Results Genetic tests confirmed the USH2 diagnosis in 5 of 7 patients examined, with 1 patient reporting a unique mutation on genetic tests. Four (80%) of the 5 patients with a genetic diagnosis of USH2 showed pathological O-VEMPs. Two patients (40%) reported bilateral absent or abnormal values of C-VEMPs. The superior semicircular canal presented a significant deficit in 2 (40%) patients. The same 2 cases showed a pathologic response of the v-HIT of the horizontal semicircular canal. Finally, the posterior semicircular canal presented a significant deficit in 4 (40.0%) patients. Conclusion A vestibular evaluation with vestibular evoked myogenic potentials and v-HIT seems to identify latent damage to the vestibular receptors of USH2 patients.
Assuntos
Proteínas da Matriz Extracelular/genética , Receptores Acoplados a Proteínas G/genética , Síndromes de Usher/genética , Síndromes de Usher/fisiopatologia , Adolescente , Adulto , Estudos Transversais , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Mutação , Testes de Função VestibularRESUMO
Introducción: La gran mayoría de lesiones que comprometen el conducto auditivo interno corresponden a schwannomas vestibulares (90%). Dentro de las nuevas pruebas diagnósticas del sistema vestibular aparece la prueba de impulso cefálico y su registro con el video Head Impulse Test (v-HIT) que permite el estudio de todos los canales semicirculares. Objetivo: Comparar el v-HIT para canales semicirculares laterales con las pruebas calóricas clásicas registradas mediante videonistagmografía en el comportamiento de los neurinomas intracanaliculares y evaluar su utilidad como test diagnóstico. Material y método: Dieciocho pacientes fueron reclutados con diagnóstico de neurinomas, confirmado mediante resonancia magnética y estudios con pruebas calóricas clásicas y v-HIT para canal horizontal. Resultados: Los resultados anormales de asimetría de ganancia y de sacadas correctivas fue de 13 pacientes (72%) y con hipoexcitabilidad en la prueba calórica fue de 9 pacientes (50%), con una sensibilidad de la prueba de 72% para vHIT y de 50% para la prueba calórica al compararlo con la resonancia magnética. Conclusión: El v-HIT es una herramienta complementaria a las pruebas calóricas y debe ser incluida como test diagnóstico dentro de la batería de exámenes para evaluar el sistema vestibular en forma completa mediante un vestibulograma.
Introduction: The majority of injuries involving the internal auditory canal correspond to vestibular schwannomas (90%). Within the new diagnostic tests for the vestibular system appears the Head Impulse test and the video head impulse test (v-HIT) which allows the studying of all the semicircular canals. Aim: Compare the v-HIT lateral semicircular canals with classical caloric tests recorded by videonistagmography (VNG) in the behavior of intracanalicular neuroma and evaluate its usefulness as a diagnostic test. Material and method: Eigtheen patients were enrolled with a diagnosis of schwannomas, confirmed by MRI and studied classical caloric tests and v-HIT for horizontal channel. Results: Abnormal results of asymmetry gain and corrective saccades was 13 patients (72%) and hypoexcitability in the caloric test was 9 patients (50%), with a test sensitivity of 72% for vHIT and 50% for caloric test compared with MRI. Conclusions: The v-HIT is a complementary tool to caloric tests and should be included as a diagnostic test within the battery of tests to evaluate the vestibular system in complete form by vestibulogram.