Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Artigo em Alemão | MEDLINE | ID: mdl-39347816

RESUMO

BACKGROUND: Critically ill patients in the intensive care unit require intensified monitoring to control the treatment with volume and/or vasoactive substances. RESEARCH QUESTION: What role does functional hemodynamic monitoring play in controlling treatment and what techniques are used to manage this? MATERIAL AND METHODS: Review of the current literature. RESULTS AND DISCUSSION: Precise knowledge of the physiology of the cardiovascular system as well as the pathophysiology of individual clinical pictures and the possibilities of invasive and noninvasive monitoring are the prerequisites for the indications, implementation and interpretation of functional hemodynamic monitoring. An understanding of the heart-lung interaction and the influence of invasive ventilation on the volumetric target parameters, such as stroke volume variation, systolic pressure variation and pulse pressure variation as well as sonography of the inferior vena cava are indispensable prerequisites for the question of volume responsiveness. Other maneuvers, such as the passive leg raising test, can be very helpful when deciding on volume administration in everyday clinical practice. Static parameters such as central venous pressure generally play no role and if any only a subordinate one.

2.
J Clin Med ; 13(6)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38542010

RESUMO

Background: Effective fluid management is important for patients at risk of increased intracranial pressure (ICP). Maintaining constant cerebral perfusion represents a challenge, as both hypovolemia and fluid overload can severely impact patient outcomes. Fluid responsiveness tests, commonly used in critical care settings, are often deemed potentially hazardous for these patients due to the risk of disrupting cerebral perfusion. Methods: This single-center, prospective, clinical observational study enrolled 40 patients at risk for increased ICP, including those with acute brain injury. Informed consent was obtained from each participant or their legal guardians before inclusion. The study focused on the dynamics of ICP and cerebral perfusion pressure (CPP) changes during the Passive Leg Raise Test (PLRT) and the End-Expiratory Occlusion Test (EEOT). Results: The results demonstrated that PLRT and EEOT caused minor and transient increases in ICP, while consistently maintaining stable CPP. EEOT induced significantly lower ICP elevations, making it particularly suitable for use in high-risk situations. Conclusions: PLRT and EEOT can be considered feasible and safe for assessing fluid responsiveness in patients at risk for increased ICP. Notably, EEOT stands out as a preferred method for high-risk patients, offering a dependable strategy for fluid management without compromising cerebral hemodynamics.

3.
Clin Kidney J ; 16(11): 1861-1877, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37915939

RESUMO

Goals of volume management are to accurately assess intravascular and extravascular volume and predict response to volume administration, vasopressor support or volume removal. Data are reviewed that support the following: (i) Dynamic parameters reliably guide volume administration and may improve clinical outcomes compared with static parameters, but some are invasive or only validated with mechanical ventilation without spontaneous breathing. (ii) Ultrasound visualization of inferior vena cava (IVC) diameter variations with respiration reliably assesses intravascular volume and predicts volume responsiveness. (iii) Although physiology of IVC respiratory variations differs with mechanical ventilation and spontaneous breathing, the IVC collapsibility index (CI) and distensibility index are interconvertible. (iv) Prediction of volume responsiveness by IVC CI is comparable for mechanical ventilation and spontaneous breathing patients. (v) Respiratory variations of subclavian/proximal axillary and internal jugular veins by ultrasound are alternative sites, with comparable reliability. (vi) Data support clinical applicability of IVC CI to predict hypotension with anesthesia, guide ultrafiltration goals, predict dry weight, predict intra-dialytic hypotension and assess acute decompensated heart failure. (vii) IVC ultrasound may complement ultrasound of heart and lungs, and abdominal organs for venous congestion, for assessing and managing volume overload and deresuscitation, renal failure and shock. (viii) IVC ultrasound has limitations including inadequate visualization. Ultrasound data should always be interpreted in clinical context. Additional studies are required to further assess and validate the role of bedside ultrasonography in clinical care.

4.
Am J Physiol Heart Circ Physiol ; 325(5): H1069-H1080, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37682234

RESUMO

Echocardiography can assess cardiac preload when fluid administration is used to treat acute circulatory failure. Changes in stroke volume (SV) are inherently a continuous phenomenon relating to the pressure gradient for venous return (VRdP). However, most clinical studies have applied a binary definition based on a fractional change in SV. This study tested the hypothesis that calculating the analog mean systemic filling pressure (Pmsa) and VRdP would enhance echocardiography to describe SV responses to a preload challenge. We investigated 540 (379 males) patients during a standardized passive leg raising (PLR) maneuver. Patients were further categorized by the presence of impaired right ventricular function (impRV) or increased intra-abdominal hypertension (IAH). Multivariable linear regression identified VRdP (partial r = -0.26, P < 0.001), ventilatory-induced variations in superior vena cava diameter (partial r = 0.43, P < 0.001), and left ventricular outflow tract maximum-Doppler velocity (partial r = 0.13, P < 0.001) as independent variables associated with SV changes. The model explained 38% (P < 0.001) of the SV change in the whole cohort and 64% (P < 0.001) when excluding patients with impRV or IAH. The correlation between Pmsa or VRdP and SV changes lost statistical significance with increasing impRV or IAH. A binary definition of volume responsiveness (>10% increase in SV) generated an area under the curve of 0.79 (P < 0.001) in logistic regression but failed to identify Pmsa or VRdP as independent variables and overlooked the confounding influence of impRV and IAH. In conclusion, venous return physiology may enhance echocardiographic assessments of volume responsiveness, which should be based on continuous changes in stroke volume.NEW & NOTEWORTHY The analog mean systemic filling pressure and the pressure gradient for venous return combined with echocardiography predict continuous changes in stroke volume following a passive leg raising maneuver. The confounding effects of impaired right ventricular function and increased intra-abdominal pressure can be identified. Using a binary cutoff for the fractional change in stroke volume, common in previous clinical research, fails to identify the importance of variables relevant to venous return physiology and confounding conditions.

5.
Front Physiol ; 14: 1234915, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37621761

RESUMO

Heart-lung interactions occur due to the mechanical influence of intrathoracic pressure and lung volume changes on cardiac and circulatory function. These interactions manifest as respiratory fluctuations in venous, pulmonary, and arterial pressures, potentially affecting stroke volume. In the context of functional hemodynamic monitoring, pulse or stroke volume variation (pulse pressure variation or stroke volume variability) are commonly employed to assess volume or preload responsiveness. However, correct interpretation of these parameters requires a comprehensive understanding of the physiological factors that determine pulse pressure and stroke volume. These factors include pleural pressure, venous return, pulmonary vessel function, lung mechanics, gas exchange, and specific cardiac factors. A comprehensive knowledge of heart-lung physiology is vital to avoid clinical misjudgments, particularly in cases of right ventricular (RV) failure or diastolic dysfunction. Therefore, when selecting monitoring devices or technologies, these factors must be considered. Invasive arterial pressure measurements of variations in breath-to-breath pressure swings are commonly used to monitor heart-lung interactions. Echocardiography or pulmonary artery catheters are valuable tools for differentiating preload responsiveness from right ventricular failure, while changes in diastolic function should be assessed alongside alterations in airway or pleural pressure, which can be approximated by esophageal pressure. In complex clinical scenarios like ARDS, combined forms of shock or right heart failure, additional information on gas exchange and pulmonary mechanics aids in the interpretation of heart-lung interactions. This review aims to describe monitoring techniques that provide clinicians with an integrative understanding of a patient's condition, enabling accurate assessment and patient care.

6.
Micromachines (Basel) ; 14(3)2023 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-36984917

RESUMO

Volume resuscitation is a cornerstone of modern anesthesia care. Finding the right balance to avoid inadequate or excess volume administration is often difficult to clinically discern and can lead to negative consequences. Pulse pressure variation is often intraoperatively used to guide volume resuscitation; however, this requires an invasive arterial line and is generally only applicable to patients who are mechanically ventilated. Unfortunately, without a pulmonary artery catheter or another costly noninvasive device, performing serial measurements of cardiac output is challenging, time-consuming, and often impractical. Furthermore, noninvasive measures such as LVOT VTI require significant technical expertise as well as access to the chest, which may not be practical during and after surgery. Other noninvasive techniques such as bioreactance and esophageal Doppler require the use of costly single-use sensors. Here, we present a case report on the use of corrected carotid flow time (ccFT) from a portable, handheld ultrasound device as a practical, noninvasive, and technically straightforward method to assess fluid responsiveness in the perioperative period, as well as the inpatient and outpatient settings.

7.
BMC Anesthesiol ; 22(1): 63, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-35260075

RESUMO

BACKGROUND: The validation of inferior vena cava (IVC) respiratory variation for predicting volume responsiveness is still under debate, especially in spontaneously breathing patients. The present study aims to verify the effectiveness and accuracy of IVC variability for volume assessment in the patients after abdominal surgery under artificially or spontaneously breathing. METHODS: A total of fifty-six patients after abdominal surgeries in the anesthesia intensive care unit ward were included. All patients received ultrasonographic examination before and after the fluid challenge of 5 ml/kg crystalloid within 15 min. The same measurements were performed when the patients were extubated. The IVC diameter, blood flow velocity-time integral of the left ventricular outflow tract, and cardiac output (CO) were recorded. Responders were defined as an increment in CO of 15% or more from baseline. RESULTS: There were 33 (58.9%) mechanically ventilated patients and 22 (39.3%) spontaneously breathing patients responding to fluid resuscitation, respectively. The area under the curve was 0.80 (95% CI: 0.68-0.90) for the IVC dimeter variation (cIVC1) in mechanically ventilated patients, 0.87 (95% CI: 0.75-0.94) for the collapsibility of IVC (cIVC2), and 0.85 (95% CI: 0.73-0.93) for the minimum IVC diameter (IVCmin) in spontaneously breathing patients. The optimal cutoff value was 15.32% for cIVC1, 30.25% for cIVC2, and 1.14 cm for IVCmin. Furthermore, the gray zone for cIVC2 was 30.72 to 38.32% and included 23.2% of spontaneously breathing patients, while 17.01 to 25.93% for cIVC1 comprising 44.6% of mechanically ventilated patients. Multivariable logistic regression analysis indicated that cIVC was an independent predictor of volume assessment for patients after surgery irrespective of breathing modes. CONCLUSION: IVC respiratory variation is validated in predicting patients' volume responsiveness after abdominal surgery irrespective of the respiratory modes. However, cIVC or IVCmin in spontaneously breathing patients was superior to cIVC in mechanically ventilated patients in terms of clinical utility, with few subjects in the gray zone for the volume responsiveness appraisal. TRIAL REGISTRATION: ChiCTR-INR-17013093 . Initial registration date was 24/10/2017.


Assuntos
Hidratação , Veia Cava Inferior , Débito Cardíaco/fisiologia , Humanos , Unidades de Terapia Intensiva , Ultrassonografia , Veia Cava Inferior/diagnóstico por imagem
8.
J Matern Fetal Neonatal Med ; 35(25): 6815-6822, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33985398

RESUMO

BACKGROUND: There are no established clinical or laboratory markers of preload adequacy and fluid responsiveness in management of neonatal shock. Functional echocardiographic preload markers are evaluated in children and adults, but there is no data in neonatal septic shock. We evaluated five functional echocardiographic preload markers during intravenous volume resuscitation in neonatal septic shock. OBJECTIVE: (1) To compare baseline functional echocardiographic preload markers between neonates with septic shock and their "matched" healthy controls. (2) To compare echocardiographic preload markers before and after intravenous volume resuscitation. METHODS: In this cohort study, we enrolled neonates with septic shock (cases) and recorded five preload markers - inferior vena cava collapsibility index (IVC-CI), left ventricular end-diastolic (LVEDV) & end-systolic volume (LVESV) and their indices (LVEDVI, LVESVI) - before initiation of intravenous fluid resuscitation (baseline evaluation). An equal number of "matched hemodynamically stable" controls were recruited, who underwent functional echocardiographic assessment once. In neonates with shock, we recorded these markers again after volume resuscitation. RESULTS: We analyzed 46 neonates (23 cases and 23 controls). Neonates with shock had significantly elevated baseline IVC-CI as compared to controls [53% (21, 100) vs. 20% (15, 24) respectively, p-value = .01). Rest 4 echocardiographic markers (LVEDV, LVESV, LVEDVI, and LVESVI) were comparable between cases and controls. Sixteen neonates (70% of 23) received intravenous fluid resuscitation and rest 7 (30%) were started directly on vasoactive drugs. None of the preload markers changed significantly after volume resuscitation as compared to the baseline values including IVC-CI, which was almost significant [74% (33, 100) at baseline to 48% (13, 93) after 10 mL/kg and 50% (40, 69) after 20 mL/kg, (p = .05). All preload markers were comparable between survivors and non-survivors. CONCLUSION: Neonates with septic shock had significantly elevated IVC-CI at baseline as compared to hemodynamically stable neonates. None of the preload markers changed significantly after volume resuscitation as compared to the baseline values including IVC-CI, which was almost significant.


Assuntos
Choque Séptico , Choque , Adulto , Recém-Nascido , Criança , Humanos , Choque Séptico/diagnóstico por imagem , Choque Séptico/terapia , Estudos de Coortes , Ecocardiografia , Hidratação , Veia Cava Inferior/diagnóstico por imagem , Biomarcadores
9.
J Anesth ; 35(4): 488-494, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33950295

RESUMO

PURPOSE: Dynamic indicators of preload currently only do reflect preload requirements of the left ventricle. To date, no dynamic indicators of right ventricular preload have been established. The aim of this study was to calculate dynamic indicators of right ventricular preload and assess their ability to predict ventricular volume responsiveness. MATERIALS AND METHODS: The study was designed as experimental trial in 20 anaesthetized pigs. Micro-tip catheters and ultrasonic flow probes were used as experimental reference to enable measurement of right ventricular stroke volume and pulse pressure. Hypovolemia was induced (withdrawal of blood 20 ml/kg) and thereafter three volume-loading steps were performed. ROC analysis was performed to assess the ability of dynamic right ventricular parameters to predict volume response. RESULTS: ROC analysis revealed an area under the curve (AUC) of 0.82 (CI 95% 0.73-0.89; p < 0.001) for right ventricular stroke volume variation (SVVRV), an AUC of 0.72 (CI 95% 0.53-0.85; p = 0.02) for pulmonary artery pulse pressure variation (PPVPA) and an AUC of 0.66 (CI 95% 0.51-0.79; p = 0.04) for pulmonary artery systolic pressure variation (SPVPA). CONCLUSIONS: In our experimental animal setting, calculating dynamic indicators of right ventricular preload is possible and appears promising in predicting volume responsiveness.


Assuntos
Ventrículos do Coração , Hipovolemia , Animais , Pressão Sanguínea , Hidratação , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica , Volume Sistólico , Suínos , Função Ventricular Direita
10.
J Appl Physiol (1985) ; 130(5): 1562-1572, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33734829

RESUMO

Collapsibility of caval vessels and stroke volume and pulse pressure variations (SVV, PPV) are used as indicators of volume responsiveness. Their behavior under increasing airway pressures and changing right ventricular afterload is incompletely understood. If the phenomena of SVV and PPV augmentation are manifestations of decreasing preload, they should be accompanied by decreasing transmural right atrial pressures. Eight healthy pigs equipped with ultrasonic flow probes on the pulmonary artery were exposed to positive end-expiratory pressure of 5 and 10 cmH2O and three volume states (Euvolemia, defined as SVV < 10%, Bleeding, and Retransfusion). SVV and PPV were calculated for the right and PPV for the left side of the circulation at increasing inspiratory airway pressures (15, 20, and 25 cmH2O). Right ventricular afterload was assessed by surrogate flow profile parameters. Transmural pressures in the right atrium and the inferior and superior caval vessels (IVC and SVC) were determined. Increasing airway pressure led to increases in ultrasonic surrogate parameters of right ventricular afterload, increasing transmural pressures in the right atrium and SVC, and a drop in transmural IVC pressure. SVV and PPV increased with increasing airway pressure, despite the increase in right atrial transmural pressure. Right ventricular stroke volume variation correlated with indicators of right ventricular afterload. This behavior was observed in both PEEP levels and all volume states. Stroke volume variation may reflect changes in right ventricular afterload rather than changes in preload.NEW & NOTEWORTHY Stroke volume variation and pulse pressure variation are used as indicators of preload or volume responsiveness of the heart. Our study shows that these variations are influenced by changes in right ventricular afterload and may therefore reflect right ventricular failure rather than pure volume responsiveness. A zone of collapse detaches the superior vena cava and its diameter variation from the right atrium.


Assuntos
Respiração Artificial , Veia Cava Superior , Animais , Pressão Sanguínea , Hemodinâmica , Volume Sistólico , Suínos , Função Ventricular Direita
11.
J Cardiothorac Vasc Anesth ; 35(5): 1509-1515, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33597088

RESUMO

In this Emerging Technology Review, a novel, wireless, wearable Doppler ultrasound patch is described as a tool for resuscitation. The device is designed, foremost, as a functional hemodynamic monitor-a simple, fast, and consistent method for measuring hemodynamic change with preload variation. More generally, functional hemodynamic monitoring is a paradigm that helps predict stroke volume response to additional intravenous volume. Because Doppler ultrasound of the left ventricular outflow tract noninvasively measures stroke volume in realtime, it increasingly is deployed for this purpose. Nevertheless, Doppler ultrasound in this manner is cumbersome, especially when repeat assessments are needed. Accordingly, peripheral arteries have been studied and various measures from the common carotid artery Doppler signal act as windows to the left ventricle. Yet, handheld Doppler ultrasound of a peripheral artery is susceptible to human measurement error and statistical limitations from inadequate beat sample size. Therefore, a wearable Doppler ultrasound capable of continuous assessment minimizes measurement inconsistencies and smooths inherent physiologic variation by sampling many more cardiac cycles. Reaffirming clinical studies, the ultrasound patch tracks immediate SV change with excellent accuracy in healthy volunteers when cardiac preload is altered by various maneuvers. The wearable ultrasound also follows jugular venous Doppler, which qualitatively trends right atrial pressure. With further clinical research and the application of artificial intelligence, the monitoring modalities with this new technology are manifold.


Assuntos
Monitorização Hemodinâmica , Inteligência Artificial , Hemodinâmica , Humanos , Volume Sistólico , Ultrassonografia Doppler
12.
J Cardiothorac Vasc Anesth ; 35(5): 1299-1306, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33317887

RESUMO

OBJECTIVES: Renal hypoperfusion is a common mechanism of cardiac surgery-related acute kidney injury (CS-AKI). However, the optimal amount of volume resuscitation to correct systemic hypoperfusion and prevent the postoperative development of CS-AKI has been a subject of debate. The goal of this study was to assess the association of volume responsiveness determined by stroke volume variation using the passive leg raise test (PLRT) at chest closure, with the development of CS-AKI according to the Kidney Disease Improving Global Outcomes criteria. DESIGN: Single-center, prospective observational study. SETTING: Tertiary hospital. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 131 patients were studied from January 2015 until May 2017. All patients underwent cardiac surgery that required cardiopulmonary bypass. Volume responsiveness was assessed at chest closure using the PRLT. Stroke volume variation from the sitting to the recumbent positions was measured by transesophageal echocardiography. Fluid responsiveness was defined as an increase of >12% of stroke volume from sitting to recumbent positions. A total of 82 (68.3%) patients were fluid-responsive versus 38 (31.6%) who were fluid-unresponsive. CS-AKI occurred in 30% of patients. There was no difference in CS-AKI between fluid-responsive and fluid-nonresponsive groups. However, CS-AKI was associated independently with an increases in body mass index and preoperative diastolic blood pressure. CS-AKI also was associated with prolonged intensive care unit length of stay. CONCLUSION: End-of-procedure volume responsiveness is not associated with a high risk for postoperative CS-AKI.


Assuntos
Injúria Renal Aguda , Procedimentos Cirúrgicos Cardíacos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Humanos , Perna (Membro) , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Fatores de Risco
13.
Ann Palliat Med ; 9(5): 3506-3512, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33065801

RESUMO

BACKGROUND: The consistency of cardiac output (CO) measured by noninvasive cardiac output monitoring (NICOM), pulse index continuous cardiac output (PiCCO), and ultrasound in the hemodynamic monitoring of critically ill patients was studied. Using the NICOM built-in passive leg raising (PLR) test, stroke volume index variation (∆SVI) was calculated and was used to predict volume responsiveness in patients with circulatory shock (excluding cardiogenic shock). METHODS: Critically ill patients requiring hemodynamic monitoring were admitted during the study period. The CO of each included patient under hemodynamic monitoring was measured by NICOM plus PiCCO or ultrasound, and the consistency of the measured COs was analyzed. By the NICOM built-in PLR test, ∆SVI was calculated and was used to predict volume responsiveness. RESULTS: The CO of 58 patients was measured by NICOM and ultrasound, and the COs measured by these two methods were consistent. The CO of 40 patients was measured by NICOM and PiCCO, and the COs measured by these two methods were consistent. The volume responsiveness of all 98 patients was assessed by the NICOM built-in PLR test. A total of 60 patients had ∆SVI >10%, so they underwent the fluid challenge. Among them, 43 patients were positive by both the NICOM built-in PLR and fluid challenge. When using ∆SVI to predict volume responsiveness in patients with circulatory shock (excluding cardiogenic shock), the area under the receiver operating characteristic curve was 0.754 (95% confidence interval, 0.626-0.856), and the cut-off value was 18% (sensitivity: 88.37%, specificity: 52.94%), indicating that ∆SVI has value in predicting the volume responsiveness of patients with noncardiogenic circulatory shock. CONCLUSIONS: NICOM had good consistency with ultrasound and PiCCO in the hemodynamic monitoring of critically ill patients and can be for hemodynamic monitoring and evaluation in critically ill patients. The ∆SVI obtained by the NICOM built-in PLR test has certain clinical value in predicting the volume responsiveness of patients with circulatory shock (excluding cardiac shock) and provides a method for evaluating the volume responsiveness of critically ill patients.


Assuntos
Estado Terminal , Monitorização Hemodinâmica , Débito Cardíaco , Hemodinâmica , Humanos , Monitorização Fisiológica , Volume Sistólico
14.
Adv Sci (Weinh) ; 7(13): 2000684, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32670769

RESUMO

Engineering dynamic systems or materials to respond to biological process is one of the major tasks in synthetic biology and will enable wide promising applications, such as robotics and smart medicine. Herein, a super-soft and dynamic DNA/dopamine-grafted-dextran hydrogel, which shows super-fast volume-responsiveness with high sensitivity upon solvents with different polarities and enables creation of electric circuits in response to microbial metabolism is reported. Synergic permanent and dynamic double networks are integrated in this hydrogel. A serials of dynamic hydrogel-based electric circuits are fabricated: 1) triggered by using water as switch, 2) triggered by using water and petroleum ether as switch pair, 3) a self-healing electric circuit; 4) remarkably, a microbial metabolism process which produces ethanol triggering electric circuit is achieved successfully. It is envisioned that the work provides a new strategy for the construction of dynamic materials, particularly DNA-based biomaterials; and the electric circuits will be highly promising in applications, such as soft robotics and intelligent systems.

15.
J Intensive Care Med ; 35(7): 650-655, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29742951

RESUMO

OBJECTIVE: Evaluation of common carotid artery (CCA) blood flow can provide valuable information regarding the hemodynamic status of a patient. Utilizing ultrasound, we aimed to evaluate the correlation between cardiac output and different hemodynamic parameters in the CCA, namely systolic carotid flow (SCF), corrected flow time (CFT), and total carotid flow (TCF). METHODS: We studied a pilot sample of 20 healthy volunteers. Hemodynamic parameters were collected in the right CCA and the heart at rest (baseline), 1-leg compression, 2-leg compression, and passive leg raise. Nonparametric Spearman correlation was calculated using STATA 13 software. RESULTS: This study demonstrated the feasibility and safety of the leg compression testing as a hemodynamic maneuver to simulate volume depletion status. We demonstrated a direct correlation between cardiac output and SCF of 0.67 with a P value < 0.001. Interestingly, TCF calculated based on volume-time integral (VTI) in the carotid artery showed positive correlation of only 0.41, with P < 0.06, and it did not reach statistical significance. We also found a positive correlation between CFT and cardiac output at baseline 0.57, with P < 0.001. CONCLUSION: Variations in cardiac preload and the subsequent alterations in cardiac output were directly translatable into variations in the carotid blood flow. This supports the potential for using carotid flow as a surrogate for cardiac output. The most promising parameters were SCF, CFT, and carotid systolic VTI. Further work is needed to validate these correlations and utilize these acquired carotid parameters to guide fluid management and predict fluid responsiveness.


Assuntos
Débito Cardíaco/fisiologia , Artéria Carótida Primitiva/fisiologia , Hemodinâmica/fisiologia , Perna (Membro)/irrigação sanguínea , Fluxo Sanguíneo Regional/fisiologia , Ultrassonografia/métodos , Adulto , Biomarcadores/análise , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Masculino , Projetos Piloto , Pressão , Estatísticas não Paramétricas
16.
Saudi J Anaesth ; 13(4): 312-317, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31572075

RESUMO

BACKGROUND: Postspinal anesthesia hypotension (PSH) in pregnant women is common and may lead to poor maternal and fetal outcome. Fluid loading in pregnant women before spinal anesthesia to prevent hypotension is of limited ability. We hypothesized that those women who are hypovolemic before spinal anesthesia may be at risk of PSH and inferior vena cava collapsibility index (IVCCI) will be able to identify hypovolemic parturients. METHODS: In this prospective observational study, n = 45 women undergoing elective lower segment cesarean section with singleton pregnancy were recruited and IVCCI in left lateral tilt (with wedge) and supine position (without wedge) were noted by M-mode ultrasound (USG) before spinal anesthesia. After spinal anesthesia, changes in blood pressure were noted till 15 min after spinal anesthesia. RESULTS: USG measurements were obtained in 40 patients and 23 of 40 patients (57.5%) had at least one episode of hypotension. Area under the ROC curve of IVCCI with wedge to predict PSH was 0.46 (95% CI 0.27, 0.64) and best cut-of value was 25.64 with a sensitivity and specificity of 60.9% and 35.5%, respectively. Area under the ROC curve of IVCCI without wedge to predict PSH was 0.38 (95% CI 0.19, 0.56) and best cut-of value was 20.4 with a sensitivity and specificity of 69.6% and 23.5%, respectively. CONCLUSION: We conclude that IVCCI is not a predictor of PSH in pregnant women undergoing elective cesarean section.

17.
Crit Care Explor ; 1(5): e0015, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-32166259

RESUMO

Resuscitation with IV fluids is a critical component in the management of sepsis. Although the optimal volume of IV fluid is unknown, there is evidence that excessive administration can be deleterious. Static measures of volume status have not proven to be meaningful resuscitative endpoints. Determination of volume responsiveness has putative benefits over static measures, but its effect on outcomes is unknown. The goal of this systematic review and meta-analysis was to determine if resuscitation with a volume responsiveness-guided approach leads to improved outcomes in septic patients. DATA SOURCES: We searched PubMed, EMBASE, CINAHL, Web of Science, Cochrane Library, and Google Scholar from inception until April 2018. STUDY SELECTION: Prospective studies of patients with sepsis, severe sepsis, or septic shock that compared volume responsiveness-guided fluid resuscitation to standard techniques and reported mortality data. DATA EXTRACTION: We extracted study details, patient characteristics, volume responsiveness assessment method, and mortality data. DATA SYNTHESIS: Of the 1,224 abstracts and 31 full-texts evaluated, four studies (total 365 patients) met inclusion criteria. Using random effects modeling, the pooled odds ratio for mortality at time of longest follow-up with a volume responsiveness-guided strategy was 0.87 (95% CI, 0.49-1.54). Pooling of clinical data was not possibly owing to heterogeneity of reporting in individual studies. CONCLUSIONS: We found no significant difference in mortality between septic patients resuscitated with a volume responsiveness-guided approach compared with standard resuscitative strategies. It remains unclear whether the findings are due to the small sample size or a true lack of efficacy of a volume responsiveness-guided approach.

18.
Braz. j. med. biol. res ; 52(9): e8827, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019564

RESUMO

This study investigated the effects of tidal volume (TV) on the diagnostic value of pulse pressure variation (PPV) and the inferior vena cava dispensability index (IVC-DI) for volume responsiveness during mechanical ventilation. In patients undergoing elective surgery with mechanical ventilation, different TVs of 6, 9, and 12 mL/kg were given for two min. The left ventricular outflow tract velocity-time integral (VTI) was measured by transthoracic echocardiography. The IVC-DI was measured at sub-xyphoid transabdominal long axis. The PPV was measured via the radial artery and served as baseline. Index measurements were repeated after fluid challenge. VTI increased by more than 15% after fluid challenge, which was considered as volume responsive. Seventy-nine patients were enrolled, 38 of whom were considered positive volume responsive. Baseline data between the response group and the non-response group were similar. Receiver operating characteristic curve confirmed PPV accuracy in diagnosing an increase in volume responsiveness with increased TV. When TV was 12 mL/kg, the PPV area under the curve (AUC) was 0.93 and the threshold value was 15.5%. IVC-DI had the highest diagnostic accuracy at a TV of 9 mL/kg and an AUC of 0.79, with a threshold value of 15.3%. When TV increased to 12 mL/kg, the IVC-DI value decreased. When the TV was 9 and 12 mL/kg, PPV showed improved performance in diagnosing volume responsiveness than did IVC-DI. PPV diagnostic accuracy in mechanically ventilated patients was higher than IVC-DI. PPV accuracy in predicting volume responsiveness was increased by increasing TV.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Respiração Artificial , Volume Sistólico/fisiologia , Veia Cava Inferior/fisiologia , Pressão Sanguínea/fisiologia , Volume de Ventilação Pulmonar/fisiologia , Veia Cava Inferior/diagnóstico por imagem , Ecocardiografia , Curva ROC
19.
Front Pediatr ; 6: 308, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30410875

RESUMO

Sepsis is a leading cause of morbidity and mortality in children with a worldwide prevalence in pediatric intensive care units of approximately 8%. Fluid bolus therapy (FBT) is a first line therapy for resuscitation of septic shock and has been a recommendation of international guidelines for nearly two decades. The evidence base supporting these guidelines are based on limited data including animal studies and case control studies. In recent times, evidence suggesting harm from fluid in terms of morbidity and mortality have generated interest in evaluating FBT. In view of this, studies of fluid restrictive strategies in adults and children have emerged. The complexity of studying FBT relates to several points. Firstly, the physiological and haemodynamic response to FBT including magnitude and duration is not well described in children. Secondly, assessment of the circulation is based on non-specific clinical signs and limited haemodynamic monitoring with limited physiological targets. Thirdly, FBT exists in a complex myriad of pathophysiological responses to sepsis and other confounding therapies. Despite this, a greater understanding of the role of FBT in terms of the physiological response and possible harm is warranted. This review outlines current knowledge and future direction for FBT in sepsis.

20.
Echocardiography ; 35(12): 1922-1925, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30338549

RESUMO

AIM: First, the inferior vena cava dilatation index (DIVC) was measured by ultrasound, and then the reliability of DIVC as an indicator to predict volume responsiveness in patients undergoing mechanical ventilation after pneumonectomy was evaluated. METHODS: Pulse indicator continuous cardiac output (Picco) as gold standard was performed to sedated mechanically ventilated post-pneumonectomy patients in intensive care unit of Nanjing Thoracic Hospital from August 2014 to December 2016. Meanwhile, ultrasound measurement to inferior vena cava (IVC) diameter at the end inspiration (Dmax ) and the end of expiration (Dmin ) was performed. DIVC = (Dmax  - Dmin )/Dmin . Above values were recorded at baseline and then after fluid resuscitation challenge (7 mL/kg hydroxyethyl starch). An increase in cardiac index of more than 15% was used as the standard for fluid responsiveness. Patients were divided into responsive group and non-responsive group. A receiver operating characteristic (ROC) curve was then used to determine the sensitivity and specificity of DIVC in predicting fluid responsiveness after pneumonectomy. RESULTS: Eighteen patients were enrolled. 10 patients were divided into responsive group and eight in non-responsive group. DIVC in responsive group was significantly higher than in non-responsive group (P < 0.01). By setting DIVC ≥ 15% as a measure of fluid responsiveness, sensitivity was 81.8% and specificity was 85.7%. CONCLUSION: DIVC is a reliable indicator of capacity responsiveness in mechanically ventilated post-pneumonectomy patients.


Assuntos
Volume Sanguíneo/fisiologia , Pneumonectomia , Ultrassonografia/métodos , Veia Cava Inferior/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Curva ROC , Respiração Artificial , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA