Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.914
Filtrar
1.
World J Urol ; 42(1): 279, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693444

RESUMO

PURPOSE: Transrectal ultrasound-guided prostate biopsy (TRUS-Bx) is associated with a 1-8% risk of post-biopsy sepsis (PBS). A recent study described an isopropyl alcohol needle washing protocol that significantly decreased PBS rates. The current study examined the efficacy of this technique in our clinic population. MATERIALS AND METHODS: Data were reviewed for 1250 consecutive patients undergoing TRUS-Bx at the Charlie Norwood VA Medical Center from January 2017 to January 2023. Needle washing was adopted in February 2021. Complications occurring within 30 days after TRUS-Bx were recorded. RESULTS: There were 912 patients in group 1 (without needle washing) and 338 in group 2 (with needle washing). Groups had equivalent demographic features, and men of African descent comprised 70% of patients. Standard 12 core biopsies were done in 83% and 82% in groups 1 and 2, respectively (p = 0.788). Total complication rates were 4% and 2% in groups 1 and 2, respectively (p = 0.077). There were 13 sepsis events in group 1 (1.4%) and none in group 2 (p = 0.027). Clavien-Dindo Grade I-III complications occurred in 25 (2.7%) and 7 (2.1%) patients in groups 1 and 2, respectively (p = 0.505). Standard antibiotic prophylaxis (PO fluoroquinolone and IM gentamicin) was given in 80% and 86% of patients in groups 1 and 2, respectively (p = 0.030). Subset analysis limited to patients who received standard prophylaxis showed a significant difference in sepsis rates (1.5% vs 0%; p = 0.036). CONCLUSIONS: Adoption of isopropyl alcohol needle washing was associated with a significant decrease in PBS events.


Assuntos
2-Propanol , Biópsia Guiada por Imagem , Próstata , Sepse , Humanos , Masculino , Sepse/prevenção & controle , Idoso , Próstata/patologia , Pessoa de Meia-Idade , 2-Propanol/administração & dosagem , Estudos Retrospectivos , Biópsia Guiada por Imagem/métodos , Neoplasias da Próstata/patologia , Ultrassonografia de Intervenção , Agulhas , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia
2.
Int J Mol Sci ; 25(8)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38673827

RESUMO

We report a study on the hydrogen bonding mechanisms of three aliphatic alcohols (2-propanol, methanol, and ethanol) and one diol (ethylene glycol) in water solution using a time-domain ellipsometer in the THz region. The dielectric response of the pure liquids is nicely modeled by the generalized Debye-Lorentz equation. For binary mixtures, we analyze the data using a modified effective Debye model, which considers H-bond rupture and reformation dynamics and the motion of the alkyl chains and of the OH groups. We focus on the properties of the water-rich region, finding anomalous behavior in the absorption properties at very low solute molar concentrations. These results, first observed in the THz region, are in line with previous findings from different experiments and can be explained by taking into account the amphiphilic nature of the alcohol molecules.


Assuntos
Álcoois , Ligação de Hidrogênio , Água , Água/química , Álcoois/química , Espectroscopia Terahertz/métodos , Etanol/química , 2-Propanol/química
3.
J Hosp Infect ; 148: 105-111, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38670495

RESUMO

BACKGROUND: Smartphones in medical settings pose infection risks due to harbouring pathogenic bacteria. AIM: This pilot study assessed the effectiveness duration of sanitization methods, focusing on 70% isopropyl alcohol wipes and ultraviolet-C (UVC) boxes, aiming to obtain preliminary data on the reduction in total bacterial load 3 h post-sanitization. METHODS: A randomized monocentric trial with two intervention arms (wipes and UVC boxes) was designed. As participants, healthcare workers from three wards at Fondazione Policlinico Universitario 'A. Gemelli' IRCCS Hospital were recruited, stratified by ward, and block randomized within each ward to control confounders. FINDINGS: Seventy-one healthcare workers, mostly nurses (62%) were included in the study. Initial bacterial load reduction was significant with both disinfection techniques, but after 3 h both methods showed increased bacterial levels, with wipes displaying potentially higher residual efficacy (P=0.056). To adequately size a trial (89% power, significance level 0.05) for assessing the residual efficacy of alcohol-impregnated wipes compared with UVC boxes at 3 h post-sanitization, 503 professionals per group were required. CONCLUSION: This study highlights the necessity for guidelines on hospital smartphone sanitization and educational initiatives for healthcare workers and patients. Further studies, adequately sized, are necessary to determine optimal sanitization intervals and assess pathogen transmission risks.


Assuntos
2-Propanol , Desinfecção , Pessoal de Saúde , Smartphone , Raios Ultravioleta , Humanos , Projetos Piloto , 2-Propanol/farmacologia , Desinfecção/métodos , Masculino , Feminino , Adulto , Carga Bacteriana , Desinfetantes/farmacologia , Pessoa de Meia-Idade , Itália
4.
Talanta ; 275: 126115, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38663068

RESUMO

High-quality DNA is an important guarantee to start downstream experiments in many biological and medical research areas. Magnetic particle-based DNA extraction methods from blood mainly depend on electrostatic adsorption in a low-pH environment. However, the strong acidic environment can influence the DNA stability. Herein, a polydopamine-functionalized magnetic particle (PDA@Fe3O4)-based protocol was developed for DNA extraction from whole blood samples. In the protocol, Mg2+ and Ca2+ were utilized to bridge the adsorption of DNA by PDA@Fe3O4 via the metal-mediated coordination. Isopropanol was found to efficiently promote DNA adsorption by triggering the change of the conformation of DNA from B-form to more compact A-form. In 50 % isopropanol solution, the DNA adsorption efficiency was nearly 100 % in the presence of 0.5 mM Ca2+ or 1.5 mM Mg2+. The role of metal ions and isopropanol in DNA adsorption was explored. The protocol averts the strong acidic environment and PCR inhibitors, such as high concentrations of salt or polyethylene glycol. It demonstrates superiority in DNA yield (59.13 ± 3.63 ng µL-1) over the commercial kit (27.33 ± 4.98 ng µL-1) and phenol-chloroform methods (37.90 ± 0.47 ng µL-1). In addition, to simplify the operastion, an automated nucleic acid extraction device was designed and fabricated to extract whole genomic DNA from blood. The feasibility of the device was verified by extracting DNA from cattle and pig blood samples. The extracted DNA was successfully applied to discriminate the beef authenticity by a duplex PCR system. The results demonstrate that the DNA extraction protocol and the automated device have great potential in blood samples.


Assuntos
2-Propanol , DNA , Indóis , Polímeros , Polímeros/química , 2-Propanol/química , DNA/química , DNA/isolamento & purificação , DNA/sangue , Indóis/química , Adsorção , Magnésio/química , Animais , Cálcio/química , Cálcio/sangue , Bovinos , Nanopartículas de Magnetita/química
5.
Chemosphere ; 356: 141869, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38575081

RESUMO

This study evaluates the repurposing of expired isopropanol (IPA) COVID-19 disinfectant (64% w/w) to pretreat algal biomass for enhancing methane (CH4) yield. The impact of harvesting methods (centrifugation and polymer flocculation) and microwave pretreatment on CH4 production from Scenedesmus sp. microalgal biomass were also investigated. Results show minimal impact of harvesting methods on the CH4 yield, with wet centrifuged and polymer-harvested biomass exhibiting comparable and low CH4 production at 66 and 74 L/kgvolatile solid, respectively. However, microalgae drying significantly increased CH4 yield compared to wet biomass, attributed to cell shrinkage and enhanced digestibility. Consequently, microwave and IPA pretreatment significantly enhanced CH4 production when applied to dried microalgae, yielding a 135% and 212% increase, respectively, compared to non-pretreated wet biomass. These findings underscore the advantage of using dried Scenedesmus sp. over wet biomass and highlight the synergistic effect of combining oven drying with IPA treatment to boost CH4 production whilst reducing COVID-19 waste.


Assuntos
Biomassa , COVID-19 , Desinfetantes , Metano , Scenedesmus , Scenedesmus/efeitos dos fármacos , Desinfetantes/farmacologia , Metano/metabolismo , COVID-19/prevenção & controle , Microalgas/efeitos dos fármacos , Polímeros/química , Polímeros/farmacologia , 2-Propanol/farmacologia , 2-Propanol/química , SARS-CoV-2/efeitos dos fármacos
6.
Appl Opt ; 63(10): 2552-2560, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568535

RESUMO

The authors propose a surface plasmon resonance (SPR) sensor based on photonic crystal fibers (PCFs) using three hexagonal ring lattices. The sensor can detect biomolecules with maximum wavelength and amplitude sensitivities of 23,000 nm/RIU and 1310.93R I U -1, respectively, in the RI range of 1.32 to 1.42. It can detect infected red blood cells with Plasmodium falciparum for RIs of 1.402, 1.373, 1.395, and 1.383 in various malaria-infected red blood cell stages, including ring phase, trophozoite phase, and schizont phase. Furthermore, the sensor will be able to detect biomolecules such as viruses, proteins, DNA/RNA strands, acetone, ethanol, hexane, isopropanol, hexanol, formic acid, allyl cyanide, and others in its range. With these impressive results and identification capacity, the proposed sensor would benefit the biomaterial field and be appropriate for the early identification of malaria disease.


Assuntos
Malária , Plasmodium falciparum , Humanos , Ressonância de Plasmônio de Superfície , 2-Propanol , Acetona
7.
Mymensingh Med J ; 33(2): 605-612, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38557547

RESUMO

Accomplishment of an ideal root canal treatment is attributed to various essential factors such as proper instrumentation, chemomechanical preparation, obturation and post endodontic restoration. The main aim of this study is to test the null hypothesis that is the moisture condition of root dentin would not affect the bond strength and sealer penetration. This is an in vitro study conducted in Department of Conservative Dentistry and Endodontics, M A Rangoonwala Dental College, Pune, India over a period of two years (from 2021 to 2023). One hundred and twenty single-rooted Premolars with fully formed apices and similar root morphology were obtained and stored in 0.1% thymol solution. The specimens were randomly assigned to 3 broad experimental groups (n=40) according to the drying protocol such as Group A- Paper points (P), Group B- diode laser (L) and Group C- isopropyl alcohol (A). For each drying protocol, the specimens were further assigned to 2 subgroups (n=20) with respect to the sealers used: AH Plus (AH) and Apexit Plus sealers (APx). The effect of drying protocol using paper points, isopropyl alcohol and diode-lasers on the bond strength and tag penetration of two different sealers to the root dentin was evaluated. Maximum overall push-out Bond strength was seen in group AH+L and least in group APx+ L. Inter-site push-out bond Strength was highest in the coronal third followed by the middle and least in the apical third of all the groups. Maximum over all depth of penetration was seen in group AH+L and minimum in group APx+L. AH plus sealer showed better bond strength, sealer penetration and adaptation to the dentinal walls compared to Apexit plus sealer, irrespective of the drying protocol followed. All the drying protocols used did not show statistically significant results in the apical thirds of root canals of all the groups.


Assuntos
Hidróxido de Cálcio , Materiais Restauradores do Canal Radicular , Humanos , Materiais Restauradores do Canal Radicular/análise , Materiais Restauradores do Canal Radicular/química , Resinas Epóxi/análise , Resinas Epóxi/química , 2-Propanol/análise , Índia , Dentina/química
8.
Can Vet J ; 65(3): 245-249, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38434162

RESUMO

Objective: Several skin preparation techniques are used in electrocardiogram (ECG) monitoring of horses. The objective of this study was to determine which methods produce the greatest signal quality using textile electrodes and standard silver/silver chloride (Ag/AgCl) electrodes. Animals and samples: Electrocardiogram data were collected using textile and Ag/AgCl electrodes simultaneously for 4 skin preparation techniques in 6 horses. Procedure: The effects of skin preparation (cleansing with isopropyl alcohol, with or without shaving the hair) and the effects of the application of a conductive gel were assessed using metrics of signal quality. Results: Shaving and cleansing with alcohol had no effect on signal quality for either electrode type. The Ag/AgCl electrodes contain a solid gel, and the application of additional gel did not affect signal quality. Data quality was significantly improved when gel was applied to textile electrodes. Furthermore, there was no difference in signal quality between electrode types when gel was used. Conclusion and clinical relevance: This study suggests that skin preparation by cleansing and/or shaving does not have a significant effect on equine ECG signal quality. When gel is used, textile electrodes are a practical alternative for Ag/AgCl electrodes, as they produce ECG recordings of the same quality.


Impact de la méthode de préparation de la peau sur la qualité de l'électrocardiogramme chez le cheval. Objectif: Plusieurs techniques de préparation de la peau sont utilisées lors de la surveillance électrocardiographique (ECG) des chevaux. L'objectif de cette étude était de déterminer quelles méthodes produisent la meilleure qualité de signal en utilisant des électrodes textiles et des électrodes standard argent/chlorure d'argent (Ag/AgCl). Animaux et échantillons: Les données d'électrocardiogramme ont été obtenues simultanément à l'aide d'électrodes textiles et d'électrodes Ag/AgCl pour 4 techniques de préparation cutanée chez 6 chevaux. Procédure: Les effets de la préparation de la peau (nettoyage à l'alcool isopropylique, avec ou sans rasage des cheveux) et les effets de l'application d'un gel conducteur ont été évalués à l'aide de métriques de qualité du signal. Résultats: Le rasage et le nettoyage à l'alcool n'ont eu aucun effet sur la qualité du signal pour les deux types d'électrodes. Les électrodes Ag/AgCl contiennent un gel solide et l'application de gel supplémentaire n'a pas affecté la qualité du signal. La qualité des données a été considérablement améliorée lorsque le gel a été appliqué sur des électrodes textiles. De plus, il n'y avait aucune différence dans la qualité du signal entre les types d'électrodes lorsque du gel était utilisé. Conclusion et pertinence clinique: Cette étude suggère que la préparation de la peau par nettoyage et/ou rasage n'a pas d'effet significatif sur la qualité du signal ECG équin. Lorsque du gel est utilisé, les électrodes textiles constituent une alternative pratique aux électrodes Ag/AgCl, car elles produisent des enregistrements ECG de même qualité.(Traduit par Dr Serge Messier).


Assuntos
2-Propanol , Eletrocardiografia , Compostos de Prata , Animais , Cavalos , Eletrocardiografia/veterinária , Etanol
9.
Biopolymers ; 115(3): e23574, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38469937

RESUMO

Nucleophilic moieties in polysaccharides (PS) with distinct higher reactivity compared with the hydroxy group are interesting for sustainable applications in chemistry, medicine, and pharmacy. An efficient heterogeneous method for the formation of such nucleophilic PS is described. Employing alcohols as slurry medium, protonated carboxymethyl (CM) PS and hydrazine hydrate are allowed to react at elevated temperatures. The CM derivatives of starch and pullulan can be transformed almost quantitatively to the corresponding hydrazides. The reaction is less efficient for CM dextrans and CM xylans. As slurry media, 2-propanol and ethanol were probed, and the results are compared with a homogeneous procedure performed in water. Overall, the heterogeneous procedure is superior compared with the homogeneous route. 2-Propanol is the best slurry medium investigated yielding PS hydrazides with the highest nitrogen content.


Assuntos
Hidrazinas , Polissacarídeos , Hidrazinas/química , Polissacarídeos/química , Polissacarídeos/síntese química , Glucanos/química , Glucanos/síntese química , Amido/química , Amido/análogos & derivados , Amido/síntese química , 2-Propanol/química , Dextranos/química , Dextranos/síntese química , Etanol/química , Xilanos/química
10.
Cutis ; 113(1): 48, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38478938

RESUMO

Readily available and comparatively inexpensive, the common alcohol swab can aid dermatologists in everything from diagnosis to preoperative and postoperative care. The 70% isopropyl alcohol swab can aid in the accurate diagnosis of lesions and skin conditions, identification of biopsy sites, and disinfection.


Assuntos
2-Propanol , Pele , Humanos , Desinfecção
11.
AORN J ; 119(4): 261-274, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38536409

RESUMO

Many surgeons request use of 10% povidone-iodine (PI) for vaginal antisepsis; however, when PI is contraindicated, some surgeons request use of chlorhexidine gluconate (CHG) instead. The purpose of this randomized controlled trial was to determine any significant differences in self-reported symptoms associated with vaginal antisepsis with either 10% PI scrub or 4% CHG with 4% isopropyl alcohol. The control group comprised 62 participants who underwent vaginal antisepsis with the PI product, and the intervention group comprised 58 participants who underwent vaginal antisepsis with the CHG product. Participants completed surveys immediately before surgery, immediately after surgery, and 48 to 72 hours after surgery. No significant differences were found in the reported vaginal symptoms between the two groups for any survey. One participant in the intervention group reported symptoms consistent with an allergic reaction. Additional studies are needed on the use of CHG for vaginal antisepsis.


Assuntos
Anti-Infecciosos Locais , Clorexidina/análogos & derivados , Feminino , Humanos , Anti-Infecciosos Locais/uso terapêutico , Povidona-Iodo/uso terapêutico , 2-Propanol/uso terapêutico , Infecção da Ferida Cirúrgica/prevenção & controle , Cuidados Pré-Operatórios , Clorexidina/uso terapêutico , Antissepsia
12.
J Forensic Sci ; 69(3): 1002-1010, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38380584

RESUMO

Plastic bags, such as ziplock bags, have been used to transport illicit materials worldwide; however, very few studies have tried to optimize the recovery of DNA from these items. This study reports on the best combination of swabs and moistening solution for the greatest recovery of cellular material from ziplock bags. Five swabs, two different variations of Copan Diagnostics nylon 4N6FLOQSwabs, one Medical Wire rayon DRYSWAB, one IsoHelix rayon swab, and one Livingstone cotton swab, were evaluated with two moistening solutions, Triton X-100 in either distilled water or isopropanol. Fingermarks were deposited on ziplock bags and stained with Diamond™ Nucleic Acid Dye to allow visualization of the cells pre- and post-swabbing to determine the number of cells recovered. Based on cell counting data, swabs moistened with Triton X-100 in distilled water performed better than those moistened with isopropanol. Livingstone cotton swabs had the worst recovery of cellular material, while the other swabs tested had no significant difference in their respective solutions. A comparison of the best three swabs for cellular recovery yielded no differences in the DNA concentration extracted. A linear relationship was observed between the log number of cells recovered by swabbing and the DNA concentration following extraction and quantification. The process of monitoring cell collection using fluorescence microscopy on ziplock bags allowed evaluation of swabbing efficacy. Additionally, this study highlights the ability to evaluate cellular recovery independently of traditional extraction, quantification, or profiling techniques which may unequally affect samples.


Assuntos
2-Propanol , DNA , Microscopia de Fluorescência , Octoxinol , Manejo de Espécimes , Humanos , Manejo de Espécimes/métodos , Manejo de Espécimes/instrumentação , DNA/isolamento & purificação , DNA/análise , Dermatoglifia , Impressões Digitais de DNA , Contagem de Células
13.
Anal Bioanal Chem ; 416(8): 1867-1881, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38349535

RESUMO

The sample preparation step is pivotal in glycoproteomic analysis. An effective approach in glycoprotein sample preparation involves enriching glycopeptides by solid-phase extraction (SPE) using polar stationary phases in hydrophilic interaction liquid chromatography (HILIC) mode. The aim of this work is to show how different experimental conditions influence the enrichment efficiency of glycopeptides from human immunoglobulin G (IgG) on an aminopropyl-modified SPE column. Different compositions of the elution solvent (acetonitrile, methanol, and isopropanol), along with varying concentrations of elution solvent acidifiers (formic and acetic acid), and different concentrations of acetonitrile for the conditioning and washing solvents (65%, 75%, and 85% acetonitrile) were tested to observe their effects on the glycopeptide enrichment process. Isopropanol proved less effective in enriching glycopeptides, while acetonitrile was the most efficient, with methanol in between. Higher formic acid concentrations in the elution solvent weakened the ionic interactions, particularly with sialylated glycopeptides. Substituting formic acid with acetic acid led to earlier elution of more glycopeptides. The acetonitrile concentration in conditioning and washing solutions played a key role; at 65% acetonitrile, glycopeptides were not retained on the SPE column and were detected in the flow-through fraction. Ultimately, it was proven that the enrichment method was applicable to human plasma samples, resulting in a significant decrease in the abundances of non-glycosylated peptides. To the best of our knowledge, this study represents the first systematic investigation into the impact of the mobile phase on glycopeptide enrichment using an aminopropyl-modified SPE column in HILIC mode. This study demonstrates the substantial impact of even minor variations in experimental conditions, which have not yet been considered in the literature, on SPE-HILIC glycopeptide enrichment. Consequently, meticulous optimization of these conditions is imperative to enhance the specificity and selectivity of glycoproteomic analysis, ensuring accurate and reliable quantification.


Assuntos
Formiatos , Glicopeptídeos , Metanol , Humanos , Glicopeptídeos/química , 2-Propanol , Cromatografia Líquida/métodos , Solventes , Imunoglobulina G/química , Interações Hidrofóbicas e Hidrofílicas , Extração em Fase Sólida/métodos , Acetonitrilas , Acetatos
14.
World J Microbiol Biotechnol ; 40(3): 96, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38349591

RESUMO

The preservation of drug stability in biological evidence during the processes of collection and storage poses a substantial obstacle to the progress of forensic investigations. In conjunction with other constituents, the microorganisms present in the samples play a vital role in this investigation. The present investigation employed the high-performance liquid chromatography (HPLC) technique to assess the stability of (1R,2 S)-(-)-2-methylamino-1-phenyl-1-propanol hydrochloride in plasma and urine samples that were inoculated with Escherichia coli. These samples were subjected to storage conditions of 37 °C for 48 h and - 20 °C for a duration of 6 months. Minimal inhibitory concentration (MIC) and Minimal bactericidal concentration (MBC) of MPPH against E. coli were determined using microdilution method. The stability of MPPH in plasma and urine samples inoculated with E. coli was investigated using HPLC method. The results showed the MIC and MBC of MPPH were 87.5 ± 25 ppm and 175 ± 50 ppm, respectively. While MPPH remained stable in plasma for 48 h at 37 °C, it showed a notable decrease of about 11% in stability when stored in urine for the same period and temperature. From the beginning of the first month, a decrease in the stability of the compound appeared in all samples that were stored at - 20 °C, and the decrease reached 7% for plasma samples and about 11% for urine samples. The decrease in the stability reached its peak in the sixth month, reaching more than 30% and 70% of plasma and urine samples preserved at - 20 °C. This work concluded that E. coli can negatively affect the stability of MPPH in plasma and urine samples. This may lead to incorrect conclusions regarding the analysis of biological samples in criminal cases.


Assuntos
1-Propanol , Escherichia coli , Cromatografia Líquida de Alta Pressão , 2-Propanol , Testes de Sensibilidade Microbiana
15.
Chemosphere ; 352: 141307, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38307338

RESUMO

The present study compares the effect of using different solvents on the electrochemical properties of the reduced TiO2 nanotubes (TiO2-rNTs) layered Ti/TiO2-rNTs/SnO2-Sb/PbO2 anodes. The electrodes are prepared using three different solvent-based precursors: (i) isopropanol, (ii) ethylene glycol and citric acid (Pechini method), and (iii) 2-hydroxyethylammonium acetate (2HEAA) ionic liquid (IL) via the thermal decomposition route. The decomposition mechanism of precursor solutions was explored using the thermogravimetric (TGA) analysis. Further, the physicochemical properties of the electrodes are examined using Field emission Scanning Electron microscopy (FE-SEM), X-ray diffraction spectroscopy (XRD), and X-ray photoelectron emission spectroscopy (XPS). The results revealed that solvents with higher viscosity and slower decomposition rates support better film uniformity and higher stability of the electrode. The TiO2 -rNTs bottom layer and PbO2 top layer helped obtain higher film stability, increased working potential window (2.2 V vs. SHE) of the electrode, and the repeatability of the results. The performance of different electrodes based on the precursor solution is found as IL â‰« Pechini > Isopropanol. 4-chlorophenol (4-CP) is used as a model pollutant to test the performance of IL-Ti/TiO2-rNTs/SnO2-Sb/PbO2 anode in an anodic oxidation (AO) coupled electro-Fenton (EF) treatment. Further, the reliability of the electrode is evaluated by mineralizing other persistent organic pollutants (POPs) like tetracyclin, phenol, 2-chlorophenol (2-CP), and 2,4-dichlorophenol (2,4-DCP). Under the optimized conditions, the proposed system was able to mineralize the tetracyclin, phenol, 2-CP, 2,4-DCP, and 4-CP up to 78.91, 82.07, 74.96, 78.78, and 69.3 %, respectively. Moreover, the degradation mechanism of chlorophenols is proposed.


Assuntos
Óxidos , Poluentes Químicos da Água , Óxidos/química , Poluentes Orgânicos Persistentes , 2-Propanol , Reprodutibilidade dos Testes , Titânio/química , Oxirredução , Fenóis , Fenol/química , Eletrodos , Solventes , Poluentes Químicos da Água/química
16.
Bioresour Technol ; 396: 130416, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38316230

RESUMO

Isopropanol, a well-known biofuel, is a widely used precursor for chemical products that can replace nonrenewable petroleum energy. Here, engineered Corynebacterium glutamicum that can effectively utilize all xylose and glucose in agricultural waste rice straw to produce isopropanol was described. First, codon mutations were introduced into transporters and glycolytic-related genes to decrease the glucose preference of C. glutamicum. A more energetically favorable xylose oxidative pathway was constructed that replaced traditional xylose isomerization pathways, saving twice the number of enzymatic steps. A succinate auxiliary module was incorporated into the tricarboxylic acid cycle (TCA), connecting the xylose-utilized pathway with the isopropanol pathway to maximize xylose orientation towards the product. The final engineered strain successfully consumed 100 % of the xylose from NaOH-pretreated, enzyme-hydrolyzed rice straw and effectively synthesized 4.91 g/L isopropanol. This study showcases the successful conversion of agricultural waste into renewable energy, unveiling new possibilities for advancing biological fermentation technology.


Assuntos
Corynebacterium glutamicum , Oryza , Xilose/metabolismo , Corynebacterium glutamicum/genética , Corynebacterium glutamicum/metabolismo , Oryza/metabolismo , 2-Propanol , Biomassa , Glucose/metabolismo , Engenharia Metabólica , Fermentação
17.
Int J Pharm ; 653: 123886, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38331330

RESUMO

Dandruff, or pityriasis capitis simplex, is a common scalp condition associated with excessive flaking and scaling of the epidermal tissue. Other features include irregular corneocyte turnover, irritation, itching and an impaired skin barrier function. Previously we reported the characterization of climbazole (CBZ), an antifungal agent used in the management of dandruff. Skin permeation of CBZ from neat solvents was also investigated. In the present work we evaluated CBZ permeation in human skin in vitro from more complex formulations that better represent products used by consumers. The various systems studied were composed of propylene glycol (PG), Transcutol®P (TC), octyl salicylate (OSal) and isopropyl alcohol (IPA). As well as measurement of skin uptake and penetration of CBZ, where possible, the skin retention and permeation of the various solvents was also determined. All vehicles promoted skin permeation of CBZ but no significant differences in amount permeated were evident between the binary vehicles (PG:TC, TC:OSal) and the ternary vehicle studied (PG:IPA:OSal). The binary vehicles generally promoted more skin uptake of CBZ compared with the neat solvents (PG, TC, OSal) studied previously. Permeation and skin extraction of CBZ from the PG:TC vehicles increased with increasing PG content; a similar trend was evident for the PG:IPA:OSal systems. New methods were developed and validated for measurement of PG, TC and OSal. Analysis of the individual solvents indicated that PG permeation was also independent of the amounts of other solvents in the binary or ternary systems. Consistent with previous findings higher proportions of TC permeated compared with PG for the PG:TC binary systems; TC also permeated the skin more rapidly than PG from these vehicles. For OSal, skin extraction was generally higher for TC:OSal compared with the PG:IPA:OSal vehicle. However, increasing the content of OSal did not appear to influence CBZ skin uptake nor permeation. Interestingly, the effects of the various PG:TC vehicles on CBZ skin delivery contrast with results we previous reported for the same systems for a different active. This confirms that with reference to skin permeation, formulation effects and/or skin penetration enhancement should be expected to vary and may not be predicted for specific vehicles.


Assuntos
Caspa , Imidazóis , Humanos , Administração Cutânea , Pele , Solventes , Propilenoglicol , 2-Propanol , Permeabilidade
18.
BJS Open ; 8(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38364056

RESUMO

BACKGROUND: The application of antiseptic skin agents prior to incision minimizes the rate of surgical site infection. Despite their ubiquity, the optimal skin preparation agent remains uncertain. A retrospective economic analysis was conducted to complement the results from the NEWSkin Prep trial which prospectively compared three preparation agents. METHODS: A cost and cost-effectiveness analysis was performed from a healthcare service perspective to compare chlorhexidine with 70% ethanol, and aqueous povidone-iodine, against povidone-iodine with 70% ethanol. Resource use estimates accounted for hospital admissions, readmissions associated with surgical site infection, outpatient and general practitioner attendances, visits from community nurses and therapeutic consumables. The measure of effectiveness comprised the net difference in number of patients with surgical site infections per 1000 patients. Costs were compared using a two-sample Welch's t-test. Deterministic and probabilistic sensitivity analyses were performed to evaluate the incremental cost-effectiveness ratio. RESULTS: The null hypothesis that the mean costs for the trial arms were significantly different was not rejected (Welch's t-test P value: 0.771 for chlorhexidine with 70% ethanol against povidone-iodine with 70% ethanol; and 0.955 for aqueous povidone-iodine against povidone-iodine with 70% ethanol). Based on bootstrap averages, the chlorhexidine with 70% ethanol intervention generated 8.0 fewer surgical site infections per 1000 patients and net cost savings of €151,698 (Euros) per 1000 patients compared with povidone-iodine with 70% ethanol, and aqueous povidone-iodine produced a net cost saving of €37,494 per 1000 patients but generated an additional 11.6 surgical site infections per 1000 patients compared with povidone-iodine with 70% ethanol. The comparison of chlorhexidine with 70% ethanol to povidone-iodine with 70% ethanol was sensitive to the inclusion of cost outliers, while the comparison of aqueous povidone-iodine to povidone-iodine with 70% ethanol was sensitive to the estimated cost per surgical site infection. CONCLUSION: Based on the outcomes from the NEWSkin Prep study, this economic analysis found no definitive evidence in favour of any one of the study comparators. Future model-based economic analyses of alternative skin preparations should critically address the quality of evidence and integrate the results from the NEWSkin Prep study.


Assuntos
Anti-Infecciosos Locais , Povidona-Iodo , Humanos , Povidona-Iodo/uso terapêutico , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Clorexidina/uso terapêutico , Análise de Custo-Efetividade , Estudos Retrospectivos , Anti-Infecciosos Locais/uso terapêutico , Etanol , 2-Propanol/uso terapêutico
19.
N Engl J Med ; 390(5): 409-420, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38294973

RESUMO

BACKGROUND: Studies evaluating surgical-site infection have had conflicting results with respect to the use of alcohol solutions containing iodine povacrylex or chlorhexidine gluconate as skin antisepsis before surgery to repair a fractured limb (i.e., an extremity fracture). METHODS: In a cluster-randomized, crossover trial at 25 hospitals in the United States and Canada, we randomly assigned hospitals to use a solution of 0.7% iodine povacrylex in 74% isopropyl alcohol (iodine group) or 2% chlorhexidine gluconate in 70% isopropyl alcohol (chlorhexidine group) as preoperative antisepsis for surgical procedures to repair extremity fractures. Every 2 months, the hospitals alternated interventions. Separate populations of patients with either open or closed fractures were enrolled and included in the analysis. The primary outcome was surgical-site infection, which included superficial incisional infection within 30 days or deep incisional or organ-space infection within 90 days. The secondary outcome was unplanned reoperation for fracture-healing complications. RESULTS: A total of 6785 patients with a closed fracture and 1700 patients with an open fracture were included in the trial. In the closed-fracture population, surgical-site infection occurred in 77 patients (2.4%) in the iodine group and in 108 patients (3.3%) in the chlorhexidine group (odds ratio, 0.74; 95% confidence interval [CI], 0.55 to 1.00; P = 0.049). In the open-fracture population, surgical-site infection occurred in 54 patients (6.5%) in the iodine group and in 60 patients (7.3%) in the chlorhexidine group (odd ratio, 0.86; 95% CI, 0.58 to 1.27; P = 0.45). The frequencies of unplanned reoperation, 1-year outcomes, and serious adverse events were similar in the two groups. CONCLUSIONS: Among patients with closed extremity fractures, skin antisepsis with iodine povacrylex in alcohol resulted in fewer surgical-site infections than antisepsis with chlorhexidine gluconate in alcohol. In patients with open fractures, the results were similar in the two groups. (Funded by the Patient-Centered Outcomes Research Institute and the Canadian Institutes of Health Research; PREPARE ClinicalTrials.gov number, NCT03523962.).


Assuntos
Anti-Infecciosos Locais , Clorexidina , Fixação de Fratura , Fraturas Ósseas , Iodo , Infecção da Ferida Cirúrgica , Humanos , 2-Propanol/administração & dosagem , 2-Propanol/efeitos adversos , 2-Propanol/uso terapêutico , Anti-Infecciosos Locais/administração & dosagem , Anti-Infecciosos Locais/efeitos adversos , Anti-Infecciosos Locais/uso terapêutico , Antissepsia/métodos , Canadá , Clorexidina/administração & dosagem , Clorexidina/efeitos adversos , Clorexidina/uso terapêutico , Etanol , Extremidades/lesões , Extremidades/microbiologia , Extremidades/cirurgia , Iodo/administração & dosagem , Iodo/efeitos adversos , Iodo/uso terapêutico , Cuidados Pré-Operatórios/efeitos adversos , Cuidados Pré-Operatórios/métodos , Pele/microbiologia , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Fraturas Ósseas/cirurgia , Estudos Cross-Over , Estados Unidos
20.
Infect Control Hosp Epidemiol ; 45(5): 576-582, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38213184

RESUMO

BACKGROUND: Needleless connectors (NCs) can be disinfected using antiseptic barrier caps (ABCs) to reduce the risk of catheter-related bloodstream infections. However, recent evidence suggests that isopropanol can leak from the ABC into the NC, posing concern about their safe use. We sought to determine in vitro which ABC and NC parameters influence the leakage of isopropanol through the infusion circuit. METHODS: We assessed 13 NCs and 4 ABCs available in the European market. In vitro circuits consisting of an isopropanol cap, a NC, and an 11-cm catheter line were created. The circuits were left in place for 1 to 7 days at room temperature to assess the kinetics of isopropanol leakage. Isopropanol content in ABC and in circuit flushing solutions (5 mL NaCl 0.9%) after exposure to the cap were measured using gas chromatography with a flame ionization detector. RESULTS: The leakage of isopropanol from the cap to the NC was dependent on the NC, but not the cap. The NC mechanism did not predict the leakage of isopropanol. The Q-Syte NC exhibited the most isopropanol leakage (7.01±1.03 mg and 28.32±2.62 mg at 24 hours and 7 days, respectively), whereas the Caresite NC had the lowest isopropanol leakage at 7 days (1.69±0.01 mg). CONCLUSION: The use of isopropanol ABCs can cause isopropanol leakage into the catheter circuit according to NC parameters. Caution should be exercised when using these devices, especially in the pediatric and neonatal population.


Assuntos
2-Propanol , Anti-Infecciosos Locais , Recém-Nascido , Humanos , Criança , Cateteres de Demora , Contaminação de Equipamentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA